EP404.pdf

PDF 5 MB Posted

Attached to
FY13 Flight Activity Facility, Lakehurst Naval Station, New Jersey
Solicitation number
W912DS-13-R-0017
Issued by

About this file

Revised Drawings

View the file

Other files

File Type Posted
EP602.pdf PDF
EP407.pdf PDF
EP601.pdf PDF
EP411.pdf PDF
10_56_26.pdf PDF
ET105.pdf PDF
M-701.pdf PDF
ES105.pdf PDF
Amendment_0007.pdf PDF
A-606.pdf PDF
41_22_13.15.pdf PDF
F-103.pdf PDF
ET601.pdf PDF
ET106.pdf PDF
ET103.pdf PDF
Amendment_0006_Attachment_6.pdf PDF
Amendment_0006_Attachment_4.pdf PDF
Amendment_0006_Attachment_2.pdf PDF
Amendment_0006_Attachment_10.pdf PDF
Amendment_0006_Attachment_3.pdf PDF
Amendment_0006_Attachment_9.pdf PDF
Amendment_0006_Attachment_8.pdf PDF
Amendment_0006.pdf PDF
Amendment_0006_Attachment_1.pdf PDF
Amendment_0006_Attachment_5.pdf PDF
Amendment_0006_Attachment_7.pdf PDF
Amendment_0005_Revised_Drawings.pdf PDF
Amendment_0005.pdf PDF
WBS_Fill-In.pdf PDF
Revised_drawings_-_Amendment_4.pdf PDF
Amendment_0004.pdf PDF
Specifications_-_Amendment__4.pdf PDF
Revised_Civil_Drawings_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_2_-_Amendment_3.pdf PDF
Specifications_-_Amendment_3.pdf PDF
Revised_Architectural_Drawing_1_-_Amendment_3.pdf PDF
Revised_Interior_Drawings_-_Amendment_3.pdf PDF
AMENDMENT_0003.pdf PDF
Amendment_0002.pdf PDF
Amendment_2 _Revised_Specs..pdf PDF
Amendment_2 _Drawings.pdf PDF
Drawings_1__M-306_and_M-603.pdf PDF
Amendment_0001.pdf PDF
Drawings_2___B-107_THRU_B-111.pdf PDF
Drawing_Vol_1B_.pdf PDF
00800_Exhibits.pdf PDF
Drawing_Vol_2C.pdf PDF
Spec_-_Volume_2.pdf PDF
Drawing_Vol_1A_.pdf PDF
Drawing_Vol_2A.pdf PDF
Show 40 more

Latest 50 of 54 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

J J J

DC DC

JJ

J J JJ J

J

5 5.5 6 6.8 6.9 7

P.2

P.1

P.5

P.6

5.8

AVIONICS

SHOP

AV

A V

- 1

A V

- 1 9, ,2

A V

- 1 3, ,1

A V

- 1 0, ,1

A V

- 7A V

- 4 ,6

,8

A V

- 2A V

- 1 ,3

,5

2 1

4'

0" A

FF

4' - 0"

AFF

4' - 0"

AFF

4' - 0"

AFF

4' - 0"

AFF

AV - 9

AV - 16

AV - 11

4' - 0"

AFF4' - 0"

AFF

4' - 0"

AFF

4' - 0"

AFF

AV - 20,22,24

AV - 25

4' - 0"

AFF

8 7 6 4 3

AV - 28,30

AV - 29

AV - 32AV - 31

AV - 34

5.9 7.1

4'

0" A

FF

4' - 0"

AFF

4' - 0"

AFF

AV - 37,39

AV - 33AV - 35

M

AY

N

YD

A

/E B

O R

D

ER

FI

LE

N

AM

E:

S ub m itt ed b y:

Pl ot

D at e:

FS

B

Te le ph on e

0-

, F ax

-7

B ro ad w ay E xt

St e

0, O kl ah om a C ity , O

K Ar ch ite ct s

En gi ne er s Pl an ne rs

A N

SI

D

U . S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

N

EW

Y O

R K ht tp w w w

.n an

.u sa ce .a rm y.

m il

FS

B

/0 2/

S O

L-

-B -N

U M

B

W

FY

Q

-1 0-

D -0

FY

C

ER

D

EC

F lig ht A ct iv ity F ac ilit y La ke hu rs t N

AE

S

JB

M cG ui re /D ix /L ak eh ur st

, N ew

J er se y

US Army Corps of Engineers

New York District

SHEET OF 530

S O

LI

C

IT

A

TI

O

N N

O

FI

LE

N

AM

E:

D W

N B

Y:

C

KD

B

Y:

D

ES

IG

N

ED

B

Y:

D

AT

E:

S

IZ

E

S U

B M

IT

TE

D B

Y:

P

LO

T D

AT

E:

C O

N

TR

A C

T N

O

P

LO

TT

E

D B

Y:

D

ES

C

R

IP

TI

O

N M

AR

K

A

PP

R

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E A

PP

R

D

2 3

C

4 5

A

B

SHEET

REFERENCE

NUMBER

0 1"

Fr an kf ur t S ho rt B ru za

THIS BAR IS ONE INCH ON

ORIGINAL DRAWING

IF NOT ONE INCH ON THIS

SHEET, ADJUST SCALES

ACCORDINGLY

GARY W.

JAMES

16166

O K L A H O M A

LI

C

EN

SE

D

PROFESS IO NA L

ENG

IN

EER

xx xx c-xx x.

dw g

C :\U se rs

\fx r\D oc um en ts

\R ev it\

2_

E le c_ fx r.r vt

6/

/2

9:

:5

A

M

6/

/2

9:

:5

A

M

EP404

E N

LA

R

G

ED

P

LA

N V

IE

W

JT

L

JT

L

P R

M

JT

L

SCALE: 1/4" = 1'-0"

1 ENLARGED POWER PLAN - AVIONICS SHOP

0 2' 4' 8'

N

SHEET KEYNOTES

1. MANUAL RETRACTABLE CABLE REEL WITH 120V

20A QUAD OUTLET ON THE END OF THE CABLE.

MOUNT REEL ABOVE CEILING. REEL ASSEMBLY

SHALL HAVE A STOPPING MECHANISM THAT

MAKES IT IMPOSSIBLE TO PULL THE OUTLET ANY

CLOSER THAN 48" FROM THE FINISHED FLOOR.

BASIS OF DESIGN; HUBBELL HBL 50 SERIES OR

EQUIVALENT.

2. MANUAL RETRACTABLE CABLE REEL WITH 208V

20A 3 PHASE L15-20R OUTLET ON THE END OF

THE CABLE. MOUNT REEL ABOVE CEILING.

REEL ASSEMBLY SHALL HAVE A STOPPING

MECHANISM THAT MAKES IT IMPOSSIBLE TO PULL

THE OUTLET ANY CLOSER THAN 48" FROM THE

FINISHED FLOOR. BASIS OF DESIGN; HUBBELL

HBL 50 SERIES OR EQUIVALENT.

3. NEMA 2-20R RECEPTACLE FOR 28VDC POWER.

4. 4"x4"x2-1/8" STEEL BOX WITH PLASTER RING

MOUNTED AT 48" AFF. BOX SHALL SERVE AS A

CONNECTION POINT BETWEEN THE 28VDC

BENCH MOUNT POWER SUPPLY OUTPUT AND

THE 28VDC OUTLETS THAT ARE MOUNTED IN

THE WALL. SEE DETAIL 1 ON SHEET EP501.

5. BENCH MOUNTED 28.5VDC 27A POWER SUPPLY.

BASIS OF DESIGN IS TDK LAMBDA HWS600-24/HD

OR EQUAL.

6. 120V CONNECTION FOR BENCH MOUNTED DC

POWER SUPPLY. USE 4"X4"X2-1/8" STEEL BOX

WITH PLASTER RING MOUNTED AT 48" AFF. BOX

SHALL HAVE A BLANK FACEPLATE WITH A SINGLE

KNOCKOUT. USE A 3C/#12 SO CORD TO RUN

FROM THE BOX TO THE POWER SUPPLY 120VAC

INPUT TERMINALS. USE A CORD CONNECTOR

AT THE KNOCKOUT IN THE FACEPLATE. TAKE

STEPS TO PROTECT CONDUCTORS FROM

INADVERTENT CONTACT.

7. BENCH MOUNTED 115/200V 3 PHASE 400HZ

3.5KVA POWER SUPPLY. BASIS OF DESIGN IS

UNITRON PP-400-T OR EQUAL.

8. 208V, 3 PHASE CONNECTION FOR BENCH

MOUNTED 400HZ POWER SUPPLY. USE 4"X4"X2-

1/8" STEEL BOX WITH PLASTER RING MOUNTED

AT 48" AFF. BOX SHALL HAVE A BLANK

FACEPLATE WITH A SINGLE KNOCKOUT. USE A

4C/#12 SO CORD TO CONNECT FROM THE BOX

TO THE 208VAC INPUT TERMINALS ON THE

BENCH MOUNTED POWER SUPPLY. USE A

CORD CONNECTOR AT THE KNOCKOUT IN THE

FACEPLATE. TAKE STEPS TO PROTECT

CONDUCTORS FROM INADVERTENT CONTACT.

9. RECEPTACLE FOR AUTOMATED EXTERNAL

DEFIBRILLATOR.

10. ELECTRICAL CONNECTION POINT FOR MODULAR

FURNITURE ELECTRICAL DEVICES.

11. ALL WALL MOUNTED RECEPTACLES AND

JUNCTION BOXES IN THIS SPACE SHALL BE

INSTALLED AT A MINIMUM OF 4'-0" AFF.

12. EMERGENCY POWER OFF (EPO) PUSHBUTTON

MOUNTED AT 48" AFF. DEVICE SHALL CONSIST

OF A RED MUSHROOM STYLE PUSHBUTTON

WITH A TWIST TO RELEASE FEATURE. THERE

SHALL BE A LIFTABLE CLEAR PROTECTIVE

PLASTIC COVER TO PREVENT INADVERTENT

ACTIVATION. ACTIVATING THIS PUSHBUTTON

SHALL ACTIVATE THE SHUNT TRIP FEATURE ON

THE MAIN BREAKER FOR PANEL AV. RE:

DETAIL 2/EP501.

13. THIS OUTLET SHALL BE DEDICATED FOR TASK

LIGHTING. THE OUTLET SHALL BE LABELED

"TASK LIGHTING". SEE DETAIL 1 AND 2 ON SHEET

EL602 FOR LIGHTING CONTROL DIAGRAM.

N

O

TE

S

A

D D

E D

, 1 , 2

R E

V 'E

D

/2 0/