F-103.pdf
PDF 288 KB Posted
- Solicitation number
- W912DS-13-R-0017
About this file
Revised Drawings
View the file
Other files
Show 40 more
Latest 50 of 54 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.1 1.3 2.1 2.7 3.2 4.6 5.5 5.8 6.9 8.1 8.2 8.3 8.6 8.8 9 P.1
P.3
P.4
P.7
P.5
P.6
P.2
X
W.8
W.6
V.9
V.8
V.7
V.4
U.8
U.4
T.6
S.1
8.58.48
7.1
8.75.95.65.35.24.74.54.13.93.43.1 3.3
102106
127 128
MATCHLINE
SEE 1/F-102
MATCHLINE
SEE 1/F-102
M
AT
C H
LI
N
E S
E E
/F
-1
M
AT
C H
LI
N
E S
E E
/F
-1
ZONE WP-2 SPRINKLER MAIN
TO HIGH-BAY HANGAR
WET-PIPE SYSTEM
ZONE WP-3 SPRINKLER MAIN TO LOW-BAY
HANGAR WET-PIPE SYSTEM.
F-401
M
AY
N
YD
A
/E B
O R
D
ER
FI
LE
N
AM
E:
S ub m itt ed b y:
Pl ot
D at e:
FS
B
Te le ph on e
0-
, F ax
-7
B ro ad w ay E xt
St e
0, O kl ah om a C ity , O
K Ar ch ite ct s
En gi ne er s Pl an ne rs
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
FS
B
/0 2/
S O
L-
-B -N
U M
B
W
FY
Q
-1 0-
D -0
FY
C
ER
D
EC
F lig ht A ct iv ity F ac ilit y La ke hu rs t N
AE
S
JB
M cG ui re /D ix /L ak eh ur st
, N ew
J er se y
US Army Corps of Engineers
New York District
SHEET OF 530
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
ED
B
Y:
D
AT
E:
S
IZ
E
S U
B M
IT
TE
D B
Y:
P
LO
T D
AT
E:
C O
N
TR
A C
T N
O
P
LO
TT
E
D B
Y:
D
ES
C
R
IP
TI
O
N M
AR
K
A
PP
R
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
D
AT
E A
PP
R
D
2 3
C
4 5
A
B
SHEET
REFERENCE
NUMBER
0 1"
Fr an kf ur t S ho rt B ru za
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
GARY W.
JAMES
16166
O K L A H O M A
LI
C
EN
S E
D
PROFESS IO NA L
ENG
INEER
xx xx c-xx x.
dw g
H :\P
R J\
\B
IM
\F P
\0
_F
P .rv t 6/
/2
2:
:0
P M
6/
/2
2:
:0
P
M
F-103
S
PR
IN
KL
ER
S
YS
TE
M P
LA
N
AR
EA
C
,D ,E
,F
LF
O
JM
E
C D
S
JM
E
SCALE: 3/32" = 1'-0"
1 SPRINKLER SYSTEM PLAN - AREA C, D, E, F
A
KEY PLAN
UP
UPUP
B
D
C
E
F G
0 5'-4" 10'-8" 21'-4"
N
FIRE SUPPRESSION DESIGN SCHEDULE - AREA C,D,E,F
RM. # ROOM NAME HAZ. NO.
001 CORRIDOR LH 1
002 CORRIDOR LH 1
003 CORRIDOR LH 1
004 CORRIDOR LH 1
005 CORRIDOR LH 1
006 CORRIDOR LH 1
007 CORRIDOR LH 1
008 CORRIDOR LH 1
009 CORRIDOR LH 1
100 VESTIBULE LH 1
101 COMPARTMENTED CONFERENCE ROOM, C LH 1,4
102 COMPARTMENTED OFFICE, B LH 1,4
103 MAN TRAP LH 1,4
104 COMPARTMENTED LAB AREA, A LH 1,3
105 SERVER ROOM OH1 1,2,4
106 OFFICE LH 1,4
107 SERVER ROOM OH1 1,2,4
108 ELECTRICAL OH1 1,2
109 ELECTRICAL OH1 1,2,4
110 COMM. OH1 1,2
111 MECHANICAL OH1 1
112 SYSTEM INTEGRATION LAB LH 1
113 FIRE PROTECTION OH1 1
114 C-2 OFFICE / LAB OH1 1,3
115 SPACE & TERRESTRIAL LAB OH1 1,3
116 SPACE & TERRESTRIAL OFFICE LH 1
117 GROUND SUPPORT EQUIPMENT OH2 1
118 HAZARDOUS WASTE OH2 1
119 VESTIBULE LH 1
120 TECH SUPPLY OH2 1
121 SPECIAL TOOLS ROOM OH2 1
122 ROTARY WING RECEPTION / WAITING LH 1
123 ROTARY WING TEAM LEADER OFFICE LH 1
124 SHEET METAL SHOP OH2 1,5
125 VESTIBULE LH 1
126 AVIONICS SHOP OH1 1,3
127 COMM. OH1 1,2
128 ELECTRICAL OH1 1,2
129 STORAGE OH2 1
130 VESTIBULE OH1 1
131 AVIATION SUPPORT FLIGHT OPS LH 1
132 DIRECTOR'S CONFERENCE ROOM LH 1
133 DIRECTOR'S RECEPTION / WAITING LH 1
134 DIRECTOR'S OFFICE LH 1
135 MAINTENANCE SUPERVISOR OFFICE LH 1
136 VESTIBULE LH 1
137 MAINTENANCE QA TEAM OFFICE LH 1
138 MAINTENANCE QC TEAM / PRODUCTION CONTROL OFFICE LH 1
139 FIXED WING SUPPORT ADMIN. LH 1
140 FIXED WING SUPPORT SHOP / STORAGE OH2 1
141 GUARDRAIL COMMON SENSOR OFFICE LH 1
142 GUARDRAIL COMMON SENSOR SHOP OH1 1,3
143 AVIATION SUPPORT SAFETY OFFICE LH 1
144 AVIATION SUPPORT STANDARDIZATION OFFICE LH 1
145 GUARDRAIL COMMON SENSOR SECURE STORAGE OH2 1
146 ALSE SUPPORT SHOP OH1 1
147 ALSE SUPPORT STORAGE OH2 1
148 BREAK ROOM LH 1
149 JANITOR OH2 1
150 WOMEN'S LH 1
151 WOMEN'S LOCKERS LH 1
152 MEN'S LH 1
153 MEN'S LOCKERS LH 1
154 MAINTENANCE LH 1
155 PRINTER / COPIER ROOM LH 1
156 BREAK ROOM LH 1
157 RECEPTION / SECURITY LH 1
158 AVIATION SUPPORT BRANCH CHIEF OFFICE LH 1
159 AVIATION SUPPORT PILOT ROOM LH 1
NOTE:
1. PROVIDE WET-PIPE SPRINKLER PROTECTION WITH A DESIGN DENSITY
AND AREA IN ACCORDANCE WITH UFC 3-600-01 TABLE 4-1 FOR THE
HAZARD INDICATED.
2. DO NOT ROUTE SPRINKLER PIPING OVER ELECTRICAL OR
COMMUNICATION EQUIPMENT.
3. PROVIDE SPRINKLER PROTECTION ABOVE AND BELOW CLOUD CEILING.
REFER TO A-120, A-121, & A-122 FOR REFLECTED CEILING PLAN.
4. ONLY PIPING SERVING SPRINKLERS FOR THIS AREA SHALL PASS OVER
AREA. SPRINKLER PIPING PENETRATIONS INTO THIS AREA SHALL BE PER
IC TECH SPEC FOR ICD/ICS 705. PROVIDE SECTIONAL CONTROL VALVE
WITH TAMPER SWITCH, FLOW SWITCH, AND INSPECTORS TEST
CONNECTION ON A SINGLE LEAD-IN TO ALL SPACES MARKED WITH THIS
NOTE.
5. DUST HAZARD.
WP-1 TO PAINT BOOTH(BID OPTION #25)
WP-1 TO ROOM 160 (BID OPTION #15)
S
C H
E D
U
LE
N O
TE
R
E V
IS
IO
N
/2 0/
File details come from the government source that posted it. Updated .