Bid Schedule_PAVE_FE 10011 0J_Paving IDIQ.xlsx

XLSX spreadsheet 54 KB Posted

Attached to
New Fort Bliss Paving IDIQ Contract
Solicitation number
W911SG27BA002
Issued by

About this file

This is a Bid Schedule for a firm fixed price Indefinite Delivery/Indefinite Quantity (IDIQ) paving construction contract at Fort Bliss, Texas with options extending to New Mexico. The contract is an 8(a) Competitive acquisition set-aside restricted to 8(a) certified firms serviced by the SBA El Paso District Office or SBA New Mexico District Office, operating under NAICS code 237310. The IDIQ ordering period consists of a twelve-month Base Year followed by four optional twelve-month periods, with individual task orders to be issued during the contract performance period. The Government reserves the right to unilaterally exercise each option period. All work shall be performed within Fort Bliss military installation and surrounding areas, including New Mexico training areas in Dona Ana and Otero counties. Applicable wage determinations are NM20260035, NM20260036, and TX20260293, with a bid guarantee required per FAR 52.228-1 (original bid bonds only, no photocopies accepted).

The Bid Schedule provides separate pricing sections for Texas (Fort Bliss Base Year) and New Mexico (Base Year Option), with unit prices including labor burden, overhead, profit, and G&A. Line items encompass general conditions, earthwork, concrete, asphalt paving, storm drain systems, pavement markings and signs, traffic control, erosion control, vehicle crash barriers, exterior improvements, miscellaneous items, perimeter protection, and electrical work. Items are priced per unit (cubic yards, acres, square yards, linear feet, each, square feet, tons, hours, hundred linear feet, and lump sum). The schedule notes that all costs must include mobilization, demobilization, labor, equipment, material, testing per specifications, installation, maintenance, and removal for stormwater pollution prevention plan (SWPPP) and traffic control plan implementation. A non-pre-priced line item (0163) is included for contingency items not otherwise specified.

View the file

Other files

File Type Posted
W911SG27BA002 Full Abstract of Offers.pdf PDF
Solicitation Amendment W911SG27BA0020003 SF 30.pdf PDF
Solicitation Amendment - W911SG27BA0020003.pdf PDF
W911SG27BA002 Second List of RFI Questions and Answers.pdf PDF
Solicitation Amendment W911SG27BA0020002 SF 30.pdf PDF
W911SG27BA002 Instructions to Bidders 3 September 2026.pdf PDF
W911SG27BA002 Solicitation RFI Questions and Answers.pdf PDF
Solicitation Amendment - W911SG27BA0020002.pdf PDF
W911SG27BA002 Instructions to Bidders (Revised).pdf PDF
Bid Schedule_PAVE_FE 10011 0J_PavingNM.pdf PDF
Solicitation Amendment - W911SG27BA002 0001.pdf PDF
Solicitation Amendment W911SG27BA002 0001 SF 30.pdf PDF
Bid Schedule_PAVE_FE 10011 0J_PavingTX.pdf PDF
W911SG27BA002 Statement of Work (2).pdf PDF
Attachment N - UFGS 32 01 16.71 Cold Milling Asphalt Paving.pdf PDF
Attachment N - UFGS 32 01 16.75 Heater Scarifying of Asphalt Paving.pdf PDF
Attachment N - UFGS 32 84 23 Underground Sprinkler Systems.pdf PDF
Attachment N - UFGS 32 17 23 Pavement Markings.pdf PDF
Attachment H - Fire Prevention Construction Guide 2025.pdf PDF
Attachment N - UFGS 32 01 13.62 Asphalt Surface Treatment.pdf PDF
Attachment L - NMDOT Spec.pdf PDF
W911SG27BA002 Statement of Work.pdf PDF
Attachment N - UFGS 26 00 00 Electrical.pdf PDF
W911SG27BA002 Instructions to Bidders.pdf PDF
Attachment N - UFGS 32 11 20 Base Course.pdf PDF
Attachment F - DPW-RFI Template Blank Form.pdf PDF
Attachment N - UFGS 03 45 33 Precast Structural Concrete.pdf PDF
Attachment K - Site Clearance and Line Marking Permit.pdf PDF
Attachment A - The Army Radiation Permit ARP.pdf PDF
Attachment D - Contractor Requirements Document.pdf PDF
GSA Categories of Labor.pdf PDF
Attachment N - UFGS 32 13 13.06 Portland Cement Concrete Pavement for Roads.pdf PDF
Attachment N - UFGS 32 11 33.13 Cement Stabilized Soil (1).pdf PDF
Attachment N - UFGS 32 01 11.51 Rubber and Paint Removal -Airfield.pdf PDF
Attachment N - UFGS 32 93 00 Exterior Improvements Plants (1).pdf PDF
Attachment N - UFGS 31 00 00 Earthwork.pdf PDF
Wage Determination TX20260293 (El Paso Highway).pdf PDF
Attachment N - UFGS 32 01 17.61 Sealing Cracks in Asphalt Paving.pdf PDF
Attachment L - TXDOT Spec.pdf PDF
Attachment N - UFGS 03 30 00 Cast-in-Place Concrete.pdf PDF
Attachment N - UFGS 05 52 00 Metal Railings.pdf PDF
Attachment N - UFGS 32 12 13 Bituminous Tack and Prime Coats.pdf PDF
Attachment N - UFGS 32 12 16 Hot-Mix Asphalt HMA for Roads.pdf PDF
Attachment N - UFGS 02 41 00 Demolition.pdf PDF
Attachment N - UFGS 34 71 13.16 Vehicle Crash Barriers.pdf PDF
Wage Determination NM20260036 (Multiple NM Highway).pdf PDF
eCRAFT Professional Categories List.pdf PDF
Attachment G - DPW SUBMITTAL FORM V.1.pdf PDF
Attachment C - Construction and Demolition Sample Report.pdf PDF
Attachment N - UFGS 32 31 13 Chain Link Fences and gates.pdf PDF
Show 40 more

Latest 50 of 62 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TX_ Base Year

IDIQ Paving Contract || Fort Bliss, TexasTexas - Base Year Option - Contract Number: XXXX-XX-XX-XXXX
GENERAL CONDITIONSQtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription
0001Haul and dispose of debris11CY$ - 0$ - 0
0002Clear and Grubbing11ACR$ - 0$ - 0
EARTHWORK1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0003Excavation11CY$ - 0$ - 0
0004Fill Material (Borrow Pit), includ spread, load, haul, exclud compaction11CY$ - 0$ - 0
0005Prepare and Roll subgrade for base course, up to 12" depth11SY$ - 0$ - 0
0006Prepare and Roll Sub-base, up to 6" depth layer11SY$ - 0$ - 0
0007Base Course Material - Crushed 3/4" stn base, compacted, 4" depth layer11SY$ - 0$ - 0
0008Base Course Material - Crushed 3/4" stn base, compacted, 6" depth layer11SY$ - 0$ - 0
0009Base Course Material - Crushed 3/4" stn base, compacted, 12" depth layer11SY$ - 0$ - 0
0010Re-compact exist. Base (6" depth)11SF$ - 0$ - 0
0011Finish Grading - it will be used after cutting or filling earth11SY$ - 0$ - 0
CONCRETE1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0012Demo-Reinf concrete pavement, incld loading, hauling, dumping, diposal11CY$ - 0$ - 0
0013Sawcut reinforced. concrete slab up to 4" - 6" depth11LF$ - 0$ - 0
0014Sawcut reinforced. concrete slab up to 7" - 12" depth11LF$ - 0$ - 0
0015Sidewalk 4" f'c=4000 psi, #3 rebar @ 16" O.C.E.W., forms, joints, finish, & curing11SF$ - 0$ - 0
0016Concrete Pavement 6" thick, f'c=4,500 psi, forms, joints, finish, & curing11SY$ - 0$ - 0
0017Concrete Pavement 10" thick, Type HEC f'c=4,500 psi, forms, joints, finish, & curing11SY$ - 0$ - 0
0018Reinforcing steel #3 to #6 bars, Grade 60 ASTM A615/A615M11Ton$ - 0$ - 0
0019Smooth Dowel 1.25" diameter x 18" long, Grade 60, Coated11EA$ - 0$ - 0
0020Concrete Curb & Gutter 6" high curb, 6" thick gutter, 24" wide, .055 C.Y./L.F11LF$ - 0$ - 0
0021Concrete Header Curb (18"x6"), forms, joints, finish (f'c= 4,000 psi)11LF$ - 0$ - 0
0022Concrete Roll-over curb (24"x6"), forms, joints, finish (f'c= 4,000 psi)11LF$ - 0$ - 0
0023Concrete Premolded 1/2" bituminous expansion joints material w/ Silicon Class 811LF$ - 0$ - 0
0024Wheel stops, precast concrete incl. dowels, 6"x10"x6'-0"11EA$ - 0$ - 0
0025ADA Curb Concrete Ramp w/ truncated dome mat11CY$ - 0$ - 0
0026Concrete Handicap Access ramp (f'c = 4,000), 5' wide, includes forms, concrete, foundation, placing, and finishing11CY$ - 0$ - 0
PAVING ASPHALT1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0027Demo-asphalt pavement, up to 3" thick, incld loading, hauling, dumping,& disposal11SY$ - 0$ - 0
0028Demo-asphalt pavement, 4" - 6" thick, incld loading, hauling, dumping,& disposal11SY$ - 0$ - 0
0029Sawcut Asphalt up to 3" depth11LF$ - 0$ - 0
0030Sawcut Asphalt up to 4" - 6" depth11LF$ - 0$ - 0
0031Prime or Tack Coat11SY$ - 0$ - 0
0032Install up to 3" deep HMAC, Type "B", "C", or "D"11SY$ - 0$ - 0
0033Chip and Seal, Two course surface treatment11SY$ - 0$ - 0
0034Cold Milling 1" to 2" deep Asphaltic Pavement11SY$ - 0$ - 0
0035Heater Scarifying of Bituminous (1-1/2" depth)11SY$ - 0$ - 0
00363" Asphalt Patching (Sawcut, Base prep, and Prime)11SY$ - 0$ - 0
0037Pavement Slurry Sealer-(one coat)11SY$ - 0$ - 0
0038Sealcoating, 2 coat coal tar pitch emulsion11SY$ - 0$ - 0
0039Sealing cracks in asphalt paving, 1" wide x 2" deep11LF$ - 0$ - 0
STORM DRAIN SYSTEMS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
004018" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
004124" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
004236" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
0043Concrete Collar (f'c=3,000 psi)11EA$ - 0$ - 0
0044Concrete Headwall11CY$ - 0$ - 0
0045Concrete Box Culvert (f'c=4,500 psi), excludes excavation and backfill11CY$ - 0$ - 0
0046Inlet Complete Special, precast (Type I, II, & III), (f'c=4,500), excav and backfill11CY$ - 0$ - 0
0047Concrete Flume (Class B) (f'c=4,500 psi), 3/8" steel diamon floor plate, 1/4" socket head machine screws @ 18" o.c., premolded 1/2" bituminous expansion joint11CY$ - 0$ - 0
0048Rip-Rap 6" thickness, not grouted11SY$ - 0$ - 0
0049Rip-Rap (Concrete Class B) (4" to 6")11CY$ - 0$ - 0
0050Remove Storm Drain Pipe (Up to 36" Diameter)11LF$ - 0$ - 0
0051Gabion Boxes, galvanized steel mesh mats or boxes, stone filled, 12" deep11SY$ - 0$ - 0
0052Cement Stabilized Backfill11CY$ - 0$ - 0
0053Concrete Trench Drain - Trench, floor, hvy duty, modular, C.I. 12"x12" Top with 2", 3", 4", 5" or 6" pipe size11LF$ - 0$ - 0
0054Utility Trench 12"wide x 24" deep11LF$ - 0$ - 0
PAVEMENT MARKINGS AND SIGNS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0055Removal of painted or thermoplastic pavement markings11SF$ - 0$ - 0
0056Acrylic waterborne pavement marking, white or yellow, 4" wide11LF$ - 0$ - 0
0057Acrylic waterborne pavement marking, white or yellow, 6" wide11LF$ - 0$ - 0
0058Acrylic waterborne pavement marking, white or yellow, 12" wide11LF$ - 0$ - 0
0059Acrylic waterborne pavement marking, white or yellow, 24" wide11LF$ - 0$ - 0
0060Acrylic waterborne pavement marking, waterborne, white or yellow, arrow & letters11LF$ - 0$ - 0
0061Painted pavement marking, thermoplastic, white or yellow, 4" wide11LF$ - 0$ - 0
0062Painted pavement marking, thermoplastic, white or yellow, 6" wide11LF$ - 0$ - 0
0063Painted pavement marking, thermoplastic, white or yellow, 12" wide11LF$ - 0$ - 0
0064Painted pavement marking, thermoplastic, white or yellow, 24" wide11LF$ - 0$ - 0
0065Painted pavement markings, thermoplastic, white or yellow, arrow & letters11SF$ - 0$ - 0
006630” x 30” Traffic Reflectorized Sign w/post, break away, & foundation - installed11EA$ - 0$ - 0
0067Remove traffic signs, foundation, fill, and patch w/ same of kind material11EA$ - 0$ - 0
0068Solar Powered Traffic Sign w/ flashing lights, post, break away, & foundation - installed11EA$ - 0$ - 0
TRAFFIC CONTROL1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0069Traffic Control Plan Design per phase - Stamp11EA$ - 0$ - 0
0070Traffic Control Plan Design per phase - No Stamp11EA$ - 0$ - 0
0071Flagman (hourly)11HR$ - 0$ - 0
007228" Min Tubular With Two Retroflective Bands11EA$ - 0$ - 0
0073Temporary Striping11LF$ - 0$ - 0
0074Temporary Barrels w/ reflectorized bands (Rent for 3 Months EA)11EA$ - 0$ - 0
0075Temporary signs 36"x36" (Rent for 1 Month EA)11EA$ - 0$ - 0
0076Temporary Jersey Barriers (Rent for 3 Months EA)11EA$ - 0$ - 0
0077Temporary Type 3 Barricades (Rent for 3 Months EA)11EA$ - 0$ - 0
0078Project Information Signage w/ non-relfective vynil film, hardware and instal. (48"x72")11EA$ - 0$ - 0
0079Traffic Information Signage w/ reflectorized background, hardware and instal. (48"x72")11EA$ - 0$ - 0
EROSION CONTROL1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0080Erosion Control, Hay Bales11LF$ - 0$ - 0
0081Erosion Control, Silt Fence, polypropylene, adverse conditions, 3' high11LF$ - 0$ - 0
0082Stabilized Construction Exit, 6" deep of #2 Gravel11SY$ - 0$ - 0
VEHICLE CRASH BARRIERS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0083Remove Guardrail11LF$ - 0$ - 0
0084Vehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C., 6"x8" posts11LF$ - 0$ - 0
0085Vehicle Guide Rails, Safety End Sections, galvanized, flared11EA$ - 0$ - 0
0086Vehicle Guide Rails, Wrap around end11EA$ - 0$ - 0
0087Pipe Bollards, 6" Dia. Steel, Concrete filled/ painted, 7ft above finish grade and 3 ft below finish grade, 2'x3'8" Concrete footing11EA$ - 0$ - 0
EXTERIOR IMPROVEMENTS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
00901 ¼" Franklin Red Rock 2" deep w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
00913/4" Desert Tan Rock 2" deep w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
00924"-6" River Rock w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
0093Landscape edging, steel edge strips, 3/16" x 4", incl. stakes11LF$ - 0$ - 0
MISCELLANEOUS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0088Topographic Survey, conventional11ACR$ - 0$ - 0
0089Final As-Built Survey per project, up to 7 sheets11EA$ - 0$ - 0
009036" Metal Handrail including installation11LF$ - 0$ - 0
PERIMETER PROTECTION1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0091Demolition, Chain Link Fence, Gates, Posts,& foundation, 6' high w/ barb wire11LF$ - 0$ - 0
0092Demolish existing gates up to 6' high, up to 20' opening, foundation, fill, and patch w/ same of kind material11LF$ - 0$ - 0
0093Temporary Chain Linke Fence, Schedule 40, 5 ft high, 9 ga. Wire, galv. Steel11LF$ - 0$ - 0
0094Chain Link Fence Industrial, double swing gates, 6'high, 20' opening, includes excavation, posts & hardware in concrete11EA$ - 0$ - 0
0095Chain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel, and 3" dia galv steel corner post11LF$ - 0$ - 0
0096Rockwall 1ft width11SF$ - 0$ - 0
0097Industrial Privacy slats, vertical, vinyl11SF$ - 0$ - 0
0098Industrial Privacy slats, diagonal, aluminum11SF$ - 0$ - 0
ELETRICAL1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0094Pole Concrete Base complete 24" to 30" up to 10 ft., forms, 4000 psi concrete, placing and finishing, rebar grade 60, and augered hole.11EA$ - 0$ - 0
0095Relocate Light Pole and Assembly (Including Concrete Base)11EA$ - 0$ - 0
0096Remove Light Pole and Assembly (Including Concrete Base)11EA$ - 0$ - 0
0097Solar Roadway Light complete system with pole, to 300W LED11EA$ - 0$ - 0
00981/2" to 3/4" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
00991" to 2" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
01002-1/2" to 3" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
01011/2" - EMT conduit to include compression type fittings, support, LBs, and field bending; up to 15'11LF$ - 0$ - 0
01023/4" - EMT conduit to include compression type fittings, support, LBs and field bending; up to 15'11LF$ - 0$ - 0
01031" to 1-1/2"- EMT conduit to include compression type fittings, support, and field bending (elbow, LBs); up to 15'11LF$ - 0$ - 0
01042" to 3"- EMT conduit to include compression type fittings, support, and field bending (elbow, LBs); up to 15'11LF$ - 0$ - 0
0105Weatherhead, clevis, insulator, and bolt; 1/2" to 1-1/4"11EA$ - 0$ - 0
0106Weatherhead, clevis, insulator and bolt; 1-1/2" to 2-1/2"11EA$ - 0$ - 0
0107Weatherhead, clevis and insulator; 3" to 4"11EA$ - 0$ - 0
01081/2" to 3/4" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
01091" to 2" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
01102-1/2" to 3" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
0111#12 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0112#10 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0113#8 to #6 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0114#4 to #2 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0115#1 to 1/0 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
01162/0 to 4/0 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0117Two hole compression lugs, and brass bolts; #4 to 3/011EA$ - 0$ - 0
0118Megger and ground resistivity test results11EA$ - 0$ - 0
01194-11/16" square x 2-1/8" deep j-box with cover11EA$ - 0$ - 0
0120Weather Proof 20 Amp GFCI duplex receptacle or 20 amp 2-pole switch including cover plate, & 4-11/16" square X 2-1/8 deep box11EA$ - 0$ - 0
01211-phase 3 wire 120/240v 125 amp 18 circuit NEMA 3R Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
01223-phase 4 wire 120/208v 125 amp 18 circuit NEMA 3R Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
01233-phase 4 wire 480Y/277v 125 amp 18 circuit NEMA 1 Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
0124Channels, steel, 1-5/8" x 1-5/8" 12 Ga., spring nuts, bolts, equipment and conduit support11LF$ - 0$ - 0
0125Electrical underground hand holes, precast concrete, with concrete cover, 13" x 24" x 12' deep, TIER 15, includes excavation, backfill, 12" gravel fill, and cast in place reinforced concrete collar 12"11EA$ - 0$ - 0
01263/4" Cu. Clad 10 ft. ground rod11EA$ - 0$ - 0
0127Bare Cu. #6 Solid11CLF$ - 0$ - 0
0128Exothermic Weld (Cadweld)11EA$ - 0$ - 0
01291/2"-3/4" Grounding Bushing11EA$ - 0$ - 0
01301"-2" Grounding Bushing11EA$ - 0$ - 0
01312-1/2"-3" Grounding Bushing11EA$ - 0$ - 0
013212"x12"x6" NEMA 111EA$ - 0$ - 0
013312"x12"x6" NEMA 3R11EA$ - 0$ - 0
0134Hole drilling, 8-12" thick concrete wall, to 1" pipe11EA$ - 0$ - 0
0135Hole drilling, 8-12" thick concrete wall, to 3" pipe11EA$ - 0$ - 0
0136Circuit Breaker, 120V 1 pole bolt on to 50A11EA$ - 0$ - 0
0137Circuit Breaker, 240V 2 pole bolt on to 50A11EA$ - 0$ - 0
0138Circuit Breaker, 240V 3 pole bolt on to 100A11EA$ - 0$ - 0
0139Circuit Breaker, 277V 1 pole bolt on to 30A11EA$ - 0$ - 0
0140Circuit Breaker, 480V 2 pole bolt on to 60A11EA$ - 0$ - 0
0141Circuit Breaker, 480V 3 pole bolt on to 100A11EA$ - 0$ - 0
01423 ph Fused Disconnect HD 240V 30A Nema 3R11EA$ - 0$ - 0
01433 ph Fused Disconnect HD 240V 60A Nema 3R11EA$ - 0$ - 0
01443 ph Fused Disconnect HD 600V 30A Nema 3R11EA$ - 0$ - 0
01453 ph Fused Disconnect HD 600V 60A Nema 3R11EA$ - 0$ - 0
0146Lighting time clock; 120v/277v11EA$ - 0$ - 0
0147Photocell 2000W; 120v/277v11EA$ - 0$ - 0
0148Enclosed Lighting contactor, 600V, electrically held, 4 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0149Enclosed Lighting contactor, 600V, electrically held, 8 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0150Enclosed Lighting contactor, 600V, electrically held, 12 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0151Enclosed Lighting contactor, 600V, electrically held, 4 - 60A contacts, 120v/277v coil11EA$ - 0$ - 0
0152Light Poles, Vintage Aluminum, not incl concrete base to 14 ft11EA$ - 0$ - 0
0153Light Poles, Aluminum, not incl concrete base to 20 ft11EA$ - 0$ - 0
0154Light Poles, Aluminum, not incl concrete base to 30 ft11EA$ - 0$ - 0
0155Light Poles, Aluminum, not incl concrete base to 40 ft11EA$ - 0$ - 0
0156Light Poles, Aluminum, bracket arms 4ft to 8ft11EA$ - 0$ - 0
0157Victorian Acorn post top LED fixture equivalent (in lumens) to 150W Metal Halide/HPS11EA$ - 0$ - 0
0158Area/Roadway/Flood Lighting Fixture pole mtd with LED equivalent (in lumens) up to 250W Metal Halide/HPS; bi-level dimming and motion sensor11EA$ - 0$ - 0
0159Area/Roadway/Flood Lighting Fixture pole mtd with LED equivalent (in lumens) above 250W to 400W Metal Halide/HPS; bi-level dimming and motion sensor11EA$ - 0$ - 0
016020 ft. Wood Pole Class 311EA$ - 0$ - 0
016130 ft. Wood Pole Class 311EA$ - 0$ - 0
016240 ft. Wood Pole Class 311EA$ - 0$ - 0
NON-PREPRICED ITEMS1QtyU/IUnit Price (Incl O&P, Labor Burden, & G&A)Price Estimate
CLINDescription1
0163NON PRE-PRICED11LS$ - 0$ - 0
$ - 0
Notes:
1Total amount in column K includes: Labor Burden, Overhead, Profit, and G&A
2All costs associated with the line items shall include: mobilization, demobilization, labor, equipment, material, testing (in accordance with specs), installation, maintenance, and removal for SWPPP and the Traffic Control Plan

NM_ Base Year

IDIQ Paving Contract || Fort Bliss, TexasNew Mexico - Base Year Option - Contract Number: XXXX-XX-XX-XXXX
GENERAL CONDITIONSQtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription
0001Haul and dispose of debris11CY$ - 0$ - 0
0002Clear and Grubbing11ACR$ - 0$ - 0
EARTHWORK1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0003Excavation11CY$ - 0$ - 0
0004Fill Material (Borrow Pit), includ spread, load, haul, exclud compaction11CY$ - 0$ - 0
0005Prepare and Roll subgrade for base course, up to 12" depth11SY$ - 0$ - 0
0006Prepare and Roll Sub-base, up to 6" depth layer11SY$ - 0$ - 0
0007Base Course Material - Crushed 3/4" stn base, compacted, 4" depth layer11SY$ - 0$ - 0
0008Base Course Material - Crushed 3/4" stn base, compacted, 6" depth layer11SY$ - 0$ - 0
0009Base Course Material - Crushed 3/4" stn base, compacted, 12" depth layer11SY$ - 0$ - 0
0010Re-compact exist. Base (6" depth)11SF$ - 0$ - 0
0011Finish Grading - it will be used after cutting or filling earth11SY$ - 0$ - 0
CONCRETE1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0012Demo-Reinf concrete pavement, incld loading, hauling, dumping, diposal11CY$ - 0$ - 0
0013Sawcut reinforced. concrete slab up to 4" - 6" depth11LF$ - 0$ - 0
0014Sawcut reinforced. concrete slab up to 7" - 12" depth11LF$ - 0$ - 0
0015Sidewalk 4" f'c=4000 psi, #3 rebar @ 16" O.C.E.W., forms, joints, finish, & curing11SF$ - 0$ - 0
0016Concrete Pavement 6" thick, f'c=4,500 psi, forms, joints, finish, & curing11SY$ - 0$ - 0
0017Concrete Pavement 10" thick, Type HEC f'c=4,500 psi, forms, joints, finish, & curing11SY$ - 0$ - 0
0018Reinforcing steel #3 to #6 bars, Grade 60 ASTM A615/A615M11Ton$ - 0$ - 0
001918" long 1.25" dia. dowels, gr 60,epoxy-coated (smooth)11EA$ - 0$ - 0
0020Concrete Curb & Gutter 6" high curb, 6" thick gutter, 24" wide, .055 C.Y./L.F11LF$ - 0$ - 0
0021Concrete Header Curb (18"x6"), forms, joints, finish (f'c= 4,000 psi)11LF$ - 0$ - 0
0022Concrete Roll-over curb (24"x6"), forms, joints, finish (f'c= 4,000 psi)11LF$ - 0$ - 0
0023Concrete Premolded 1/2" bituminous expansion joints material w/ Silicon Class 811LF$ - 0$ - 0
0024Wheel stops, precast concrete incl. dowels, 6"x10"x6'-0"11EA$ - 0$ - 0
0025ADA Curb Concrete Ramp w/ truncated dome mat11CY$ - 0$ - 0
0026Concrete Handicap Access ramp (f'c = 4,000), 5' wide, includes forms, concrete, foundation, placing, and finishing11CY$ - 0$ - 0
PAVING ASPHALT1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0027Demo-asphalt pavement, up to 3" thick, incld loading, hauling, dumping,& disposal11SY$ - 0$ - 0
0028Demo-asphalt pavement, 4" - 6" thick, incld loading, hauling, dumping,& disposal11SY$ - 0$ - 0
0029Sawcut Asphalt up to 3" depth11LF$ - 0$ - 0
0030Sawcut Asphalt up to 4" - 6" depth11LF$ - 0$ - 0
0031Prime or Tack Coat11SY$ - 0$ - 0
0032Install up to 3" deep HMAC, Type "B", "C", or "D"11SY$ - 0$ - 0
0033Chip and Seal, Two course surface treatment11SY$ - 0$ - 0
0034Cold Milling 1" to 2" deep Asphaltic Pavement11SY$ - 0$ - 0
0035Heater Scarifying of Bituminous (1-1/2" depth)11SY$ - 0$ - 0
00363" Asphalt Patching (Sawcut, Base prep, and Prime)11SY$ - 0$ - 0
0037Pavement Slurry Sealer-(one coat)11SY$ - 0$ - 0
0038Sealcoating, 2 coat coal tar pitch emulsion11SY$ - 0$ - 0
0039Sealing cracks in asphalt paving, 1" wide x 2" deep11LF$ - 0$ - 0
STORM DRAIN SYSTEMS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
004018" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
004124" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
004236" RCP Pipe (Class III) w/ gaskets includes all fittings & bedding, no excav.11LF$ - 0$ - 0
0043Concrete Collar (f'c=3,000 psi)11EA$ - 0$ - 0
0044Concrete Headwall11CY$ - 0$ - 0
0045Concrete Box Culvert (f'c=4,500 psi), excludes excavation and backfill11CY$ - 0$ - 0
0046Inlet Complete Special, precast (Type I, II, & III), (f'c=4,500), excav and backfill11CY$ - 0$ - 0
0047Concrete Flume (Class B) (f'c=4,500 psi), 3/8" steel diamon floor plate, 1/4" socket head machine screws @ 18" o.c., premolded 1/2" bituminous expansion joint11CY$ - 0$ - 0
0048Rip-Rap 6" thickness, not grouted11SY$ - 0$ - 0
0049Rip-Rap (Concrete Class B) (4" to 6")11CY$ - 0$ - 0
0050Remove Storm Drain Pipe (Up to 36" Diameter)11LF$ - 0$ - 0
0051Gabion Boxes, galvanized steel mesh mats or boxes, stone filled, 12" deep11SY$ - 0$ - 0
0052Cement Stabilized Backfill11CY$ - 0$ - 0
0053Concrete Trench Drain - Trench, floor, hvy duty, modular, C.I. 12"x12" Top with 2", 3", 4", 5" or 6" pipe size11LF$ - 0$ - 0
0054Utility Trench 12"wide x 24" deep11LF$ - 0$ - 0
PAVEMENT MARKINGS AND SIGNS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0055Removal of painted or thermoplastic pavement markings11SF$ - 0$ - 0
0056Acrylic waterborne pavement marking, white or yellow, 4" wide11LF$ - 0$ - 0
0057Acrylic waterborne pavement marking, white or yellow, 6" wide11LF$ - 0$ - 0
0058Acrylic waterborne pavement marking, white or yellow, 12" wide11LF$ - 0$ - 0
0059Acrylic waterborne pavement marking, white or yellow, 24" wide11LF$ - 0$ - 0
0060Acrylic waterborne pavement marking, waterborne, white or yellow, arrow & letters11LF$ - 0$ - 0
0061Painted pavement marking, thermoplastic, white or yellow, 4" wide11LF$ - 0$ - 0
0062Painted pavement marking, thermoplastic, white or yellow, 6" wide11LF$ - 0$ - 0
0063Painted pavement marking, thermoplastic, white or yellow, 12" wide11LF$ - 0$ - 0
0064Painted pavement marking, thermoplastic, white or yellow, 24" wide11LF$ - 0$ - 0
0065Painted pavement markings, thermoplastic, white or yellow, arrow & letters11SF$ - 0$ - 0
006630” x 30” Traffic Reflectorized Sign w/post, break away, & foundation - installed11EA$ - 0$ - 0
0067Remove traffic signs, foundation, fill, and patch w/ same of kind material11EA$ - 0$ - 0
0068Solar Powered Traffic Sign w/ flashing lights, post, break away, & foundation - installed11EA$ - 0$ - 0
TRAFFIC CONTROL1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0069Traffic Control Plan Design per phase - Stamp11EA$ - 0$ - 0
0070Traffic Control Plan Design per phase - No Stamp11EA$ - 0$ - 0
0071Flagman (hourly)11HR$ - 0$ - 0
007228" Min Tubular With Two Retroflective Bands11EA$ - 0$ - 0
0073Temporary Striping11LF$ - 0$ - 0
0074Temporary Barrels w/ reflectorized bands (Rent for 3 Months EA)11EA$ - 0$ - 0
0075Temporary signs 36"x36" (Rent for 1 Month EA)11EA$ - 0$ - 0
0076Temporary Jersey Barriers (Rent for 3 Months EA)11EA$ - 0$ - 0
0077Temporary Type 3 Barricades (Rent for 3 Months EA)11EA$ - 0$ - 0
0078Project Information Signage w/ non-relfective vynil film, hardware and instal. (48"x72")11EA$ - 0$ - 0
0079Traffic Information Signage w/ reflectorized background, hardware and instal. (48"x72")11EA$ - 0$ - 0
EROSION CONTROL1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0080Erosion Control, Hay Bales11LF$ - 0$ - 0
0081Erosion Control, Silt Fence, polypropylene, adverse conditions, 3' high11LF$ - 0$ - 0
0082Stabilized Construction Exit, 6" deep of #2 Gravel11SY$ - 0$ - 0
VEHICLE CRASH BARRIERS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0083Remove Guardrail11LF$ - 0$ - 0
0084Vehicle Guide Rails, Corrugated stl, galv. Stl posts 6'-3" O.C., 6"x8" posts11LF$ - 0$ - 0
0085Vehicle Guide Rails, Safety End Sections, galvanized, flared11EA$ - 0$ - 0
0086Vehicle Guide Rails, Wrap around end11EA$ - 0$ - 0
0087Pipe Bollards, 6" Dia. Steel, Concrete filled/ painted, 7ft above finish grade and 3 ft below finish grade, 2'x3'8" Concrete footing11EA$ - 0$ - 0
EXTERIOR IMPROVEMENTS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
00901 ¼" Franklin Red Rock 2" deep w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
00913/4" Desert Tan Rock 2" deep w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
00924"-6" River Rock w/ 20 mils woven polypropylene fabric, treated for ultraviolet radiation11SF$ - 0$ - 0
0093Landscape edging, steel edge strips, 3/16" x 4", incl. stakes11LF$ - 0$ - 0
MISCELLANEOUS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0088Topographic Survey, conventional11ACR$ - 0$ - 0
0089Final As-Built Survey per project, up to 7 sheets11EA$ - 0$ - 0
009036" Metal Handrail including installation11LF$ - 0$ - 0
PERIMETER PROTECTION1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0091Demolition, Chain Link Fence, Gates, Posts,& foundation, 6' high w/ barb wire11LF$ - 0$ - 0
0092Demolish existing gates up to 6' high, up to 20' opening, foundation, fill, and patch w/ same of kind material11LF$ - 0$ - 0
0093Temporary Chain Linke Fence, Schedule 40, 5 ft high, 9 ga. Wire, galv. Steel11LF$ - 0$ - 0
0094Chain Link Fence Industrial, double swing gates, 6'high, 20' opening, includes excavation, posts & hardware in concrete11EA$ - 0$ - 0
0095Chain Link Fence, Schedule 40, 3 Strands barb wire, 2" post @ 10' O.C., set in concrete, 6ft high, 9 ga. Wire, galv. Steel, and 3" dia galv steel corner post11LF$ - 0$ - 0
0096Rockwall 1ft width11SF$ - 0$ - 0
0097Industrial Privacy slats, vertical, vinyl11SF$ - 0$ - 0
0098Industrial Privacy slats, diagonal, aluminum11SF$ - 0$ - 0
ELETRICAL1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0094Pole Concrete Base complete 24" to 30" up to 10 ft., forms, 4000 psi concrete, placing and finishing, rebar grade 60, and augered hole.11EA$ - 0$ - 0
0095Relocate Light Pole and Assembly (Including Concrete Base)11EA$ - 0$ - 0
0096Remove Light Pole and Assembly (Including Concrete Base)11EA$ - 0$ - 0
0097Solar Roadway Light complete system with pole, to 300W LED11EA$ - 0$ - 0
00981/2" to 3/4" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
00991" to 2" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
01002-1/2" to 3" - RGS conduit to include fittings, support, tape wrap, and field bending or elbows; underground or up to 15'11LF$ - 0$ - 0
01011/2" - EMT conduit to include compression type fittings, support, LBs, and field bending; up to 15'11LF$ - 0$ - 0
01023/4" - EMT conduit to include compression type fittings, support, LBs and field bending; up to 15'11LF$ - 0$ - 0
01031" to 1-1/2"- EMT conduit to include compression type fittings, support, and field bending (elbow, LBs); up to 15'11LF$ - 0$ - 0
01042" to 3"- EMT conduit to include compression type fittings, support, and field bending (elbow, LBs); up to 15'11LF$ - 0$ - 0
0105Weatherhead, clevis, insulator, and bolt; 1/2" to 1-1/4"11EA$ - 0$ - 0
0106Weatherhead, clevis, insulator and bolt; 1-1/2" to 2-1/2"11EA$ - 0$ - 0
0107Weatherhead, clevis and insulator; 3" to 4"11EA$ - 0$ - 0
01081/2" to 3/4" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
01091" to 2" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
01102-1/2" to 3" - Sch. 80 PVC to include couplings, support, adaptors, electrical marking tape, and elbows; installed in trench11LF$ - 0$ - 0
0111#12 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0112#10 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0113#8 to #6 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0114#4 to #2 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0115#1 to 1/0 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
01162/0 to 4/0 - THHN/THWN Copper wire pulled through conduit including splices11CLF$ - 0$ - 0
0117Two hole compression lugs, and brass bolts; #4 to 3/011EA$ - 0$ - 0
0118Megger and ground resistivity test results11EA$ - 0$ - 0
01194-11/16" square x 2-1/8" deep j-box with cover11EA$ - 0$ - 0
0120Weather Proof 20 Amp GFCI duplex receptacle or 20 amp 2-pole switch including cover plate, & 4-11/16" square X 2-1/8 deep box11EA$ - 0$ - 0
01211-phase 3 wire 120/240v 125 amp 18 circuit NEMA 3R Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
01223-phase 4 wire 120/208v 125 amp 18 circuit NEMA 3R Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
01233-phase 4 wire 480Y/277v 125 amp 18 circuit NEMA 1 Panelboard including Main Breaker, Trim, and interior11EA$ - 0$ - 0
0124Channels, steel, 1-5/8" x 1-5/8" 12 Ga., spring nuts, bolts, equipment and conduit support11LF$ - 0$ - 0
0125Electrical underground hand holes, precast concrete, with concrete cover, 13" x 24" x 12' deep, TIER 15, includes excavation, backfill, 12" gravel fill, and cast in place reinforced concrete collar 12"11EA$ - 0$ - 0
01263/4" Cu. Clad 10 ft. ground rod11EA$ - 0$ - 0
0127Bare Cu. #6 Solid11CLF$ - 0$ - 0
0128Exothermic Weld (Cadweld)11EA$ - 0$ - 0
01291/2"-3/4" Grounding Bushing11EA$ - 0$ - 0
01301"-2" Grounding Bushing11EA$ - 0$ - 0
01312-1/2"-3" Grounding Bushing11EA$ - 0$ - 0
013212"x12"x6" NEMA 111EA$ - 0$ - 0
013312"x12"x6" NEMA 3R11EA$ - 0$ - 0
0134Hole drilling, 8-12" thick concrete wall, to 1" pipe11EA$ - 0$ - 0
0135Hole drilling, 8-12" thick concrete wall, to 3" pipe11EA$ - 0$ - 0
0136Circuit Breaker, 120V 1 pole bolt on to 50A11EA$ - 0$ - 0
0137Circuit Breaker, 240V 2 pole bolt on to 50A11EA$ - 0$ - 0
0138Circuit Breaker, 240V 3 pole bolt on to 100A11EA$ - 0$ - 0
0139Circuit Breaker, 277V 1 pole bolt on to 30A11EA$ - 0$ - 0
0140Circuit Breaker, 480V 2 pole bolt on to 60A11EA$ - 0$ - 0
0141Circuit Breaker, 480V 3 pole bolt on to 100A11EA$ - 0$ - 0
01423 ph Fused Disconnect HD 240V 30A Nema 3R11EA$ - 0$ - 0
01433 ph Fused Disconnect HD 240V 60A Nema 3R11EA$ - 0$ - 0
01443 ph Fused Disconnect HD 600V 30A Nema 3R11EA$ - 0$ - 0
01453 ph Fused Disconnect HD 600V 60A Nema 3R11EA$ - 0$ - 0
0146Lighting time clock; 120v/277v11EA$ - 0$ - 0
0147Photocell 2000W; 120v/277v11EA$ - 0$ - 0
0148Enclosed Lighting contactor, 600V, electrically held, 4 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0149Enclosed Lighting contactor, 600V, electrically held, 8 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0150Enclosed Lighting contactor, 600V, electrically held, 12 - 30A contacts, 120v/277v coil11EA$ - 0$ - 0
0151Enclosed Lighting contactor, 600V, electrically held, 4 - 60A contacts, 120v/277v coil11EA$ - 0$ - 0
0152Light Poles, Vintage Aluminum, not incl concrete base to 14 ft11EA$ - 0$ - 0
0153Light Poles, Aluminum, not incl concrete base to 20 ft11EA$ - 0$ - 0
0154Light Poles, Aluminum, not incl concrete base to 30 ft11EA$ - 0$ - 0
0155Light Poles, Aluminum, not incl concrete base to 40 ft11EA$ - 0$ - 0
0156Light Poles, Aluminum, bracket arms 4ft to 8ft11EA$ - 0$ - 0
0157Victorian Acorn post top LED fixture equivalent (in lumens) to 150W Metal Halide/HPS11EA$ - 0$ - 0
0158Area/Roadway/Flood Lighting Fixture pole mtd with LED equivalent (in lumens) up to 250W Metal Halide/HPS; bi-level dimming and motion sensor11EA$ - 0$ - 0
0159Area/Roadway/Flood Lighting Fixture pole mtd with LED equivalent (in lumens) above 250W to 400W Metal Halide/HPS; bi-level dimming and motion sensor11EA$ - 0$ - 0
016020 ft. Wood Pole Class 311EA$ - 0$ - 0
016130 ft. Wood Pole Class 311EA$ - 0$ - 0
016240 ft. Wood Pole Class 311EA$ - 0$ - 0
NON-PREPRICED ITEMS1QtyU/IUnit Price (Incl O&P, Labor Burden, G&A, & NM Taxes)Price Estimate
CLINDescription1
0163NON PRE-PRICED11LS$ - 0$ - 0
$ - 0
Notes:
1Total amount in column K includes: Labor Burden, Overhead, Profit, and G&A
2All costs associated with the line items shall include: mobilization, demobilization, labor, equipment, material, testing (in accordance with specs), installation, maintenance, and removal for SWPPP and the Traffic Control Plan

File details come from the government source that posted it. Updated .