8107_e1v8.pdf

PDF 242 KB Posted

Attached to
Renovation of Builiding 1701
Solicitation number
W911S717B0003
Issued by

About this file

8107_e1v8, 4 of 27

View the file

Other files

File Type Posted
Bid_Abstract,_W911S7-17-B-0003.pdf PDF
Additional_Questions_W9111S7-17-B-0003.pdf PDF
W9111S7-17-B-0003,_Repair_and_Renovation_of_Bldg_1701,_Amendment_0002.pdf PDF
Revised,_8107_mi7v8.pdf PDF
Questions_and_Answers_W911S7-17-B-0003.pdf PDF
Revised,_8107_mi6v8.pdf PDF
W911S7-17-B-0003,_Repair_Renovation_of_Bldg_1701,_Admendment_0001.pdf PDF
Revised,_8107_mi9v8.pdf PDF
Revised,_8107_mi10v8.pdf PDF
Revised,_8107_m3v8.pdf PDF
Site_Visit_Roster.pdf PDF
8107_m7v8.pdf PDF
8107_mi6v8.pdf PDF
8107_mi11v8.pdf PDF
Attachment_B,_DBA_Wages_MO170019.pdf PDF
W911S7-17-B-0003_Repair_Renovation_of_Bldg_1701.pdf PDF
8107_m6v8.pdf PDF
8107_m8v8.pdf PDF
8107_e3v8.pdf PDF
8107_a1v8.pdf PDF
8107_m2v8.pdf PDF
8107_mi12v8.pdf PDF
8107_mi10v8.pdf PDF
8107_mi3v8.pdf PDF
8107_mi2v8.pdf PDF
Attachment_A,_Statement_of_Work.pdf PDF
8107_a2v8.pdf PDF
8107_e4v8.pdf PDF
Technical_Exhibit_1,__1701_Asbestos_Report.pdf PDF
8107_mi4v8.pdf PDF
8107_m3v8.pdf PDF
8107_m1v8.pdf PDF
8107_mi1v8.pdf PDF
8107_mi5v8.pdf PDF
8107_mi8v8.pdf PDF
8107_m4v8.pdf PDF
8107_e2v8.pdf PDF
8107_a3v8.pdf PDF
8107_mi9v8.pdf PDF
8107_m5v8.pdf PDF
8107_mi7v8.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VOLTAGE LAMP MOUNTING NOTESDESCRIPTIONTYPE

CEILING

GRID

LIGHTING FIXTURE SCHEDULE NOTES: LIGHTING FIXTURE SCHEDULE

2.

1.

3.

4.

120 LED

GRID

B

E

SINGLE FACE EXIT FIXTURE WITH LED LAMPS 3

CEILING

GRID

120 F

2' X 4' LED ARCHITECTURAL TROFFER

2' X 4' LED ARCHITECTURAL TROFFER

2' X 2' LED ARCHITECTURAL TROFFER

LUMEN, 4000K

LED, HIGH

CEILING

GRID

GENERAL NOTES

LEGEND

S

C

F

SM

FAP

ABBREVIATIONS

AFF

GFCI

UNO UNLESS NOTED OTHERWISE

GROUND FAULT CIRCUIT INTERRUPTER

ABOVE FINISHED FLOOR

P

A

LUMEN 4000K

LED, LOW

2' X 4' LED ARCHITECTURAL TROFFER

2' X 2' LED ARCHITECTURAL TROFFER LUMEN, 4000K

LED, MEDIUM

120 41' X 2' CEILING MOUNTED LED WRAPAROUND DIFFUSER FIXTURE

H 120 53000K

LED, 15 WATT

5.

CEILING

GRID

SURFACE MOUNT

BOTTOM UNO

AFF TO FIXTURE

WALL 7.5'

A P

P R

D M

A D

E

D I

R E

C T

O R

A T

O

P U

B L I

W

R K

S

F O

R

L

O N

A

D

W

O

M

S S

O U

R I

D E

S C

R I

P T I

O N

R E

V I

S I

O N

S

D A

T E

A P

P R

O V

E D

D A

T E

S U

B M I

T T

E D

C H

E C

K E

D

D R

A W

N

D E

S I

G N

E D

C O

O R

D I

N A

T I

O N

D A

T E

D A

T E

D A

T E

SCALE

DATE

PROJECT NO:

OFSHEET E1 4

F I

X T

U

H E

D U

L E

A N

L

G H

T I

N G

L E

G E

N

N

T E

G

G G

A R

G G

A R

G G

A

17 NOV 2016

1' X 4' WALL MOUNTED LED INDIRECT

14.5" DIA. ROUND CEILING SURFACE MOUNTED LED FIXTURE

EXISTING BOX

MOUNT ON

HARD CEILING

M C

R E

P A

I

L D I

N G

AS SHOWN

DPW03383-6J

DRAWING NO:

LUMEN, 4000K

LED, VERY LOW

LUMEN, 4000K

LED, HIGH

SESRWE OR SEDRWE OR APPROVED EQUAL.

OTHERWISE NOTED. PROVIDE DIRECTIONAL ARROWS AND DUAL FACE WHERE INDICATED. DUALLITE BE EQUIPPED WITH A SEALED LEAD CALCIUM BATTERY PACK. FIXTURE SHALL BE SINGLE FACE UNLESS SHALL BE FURNISHED WITH FINISH TO MATCH THE HOUSING. FIXTURE SHALL BE PREWIRED AND SHALL HAVE A CLEAR, INTEGRAL POLYCARBONATE VANDAL RESISTANT FACE SHIELD. ALL MOUNTING HARDWARE STENCIL FACE SHALL HAVE 6-INCH RED LETTERS WITH A 3/4 INCH STROKE. STENCIL FACE SHALL FIXTURE HOUSING SHALL BE OF DIE CAST ALUMINUM. FINISH OF HOUSING SHALL BE WHITE. WHITE

G

J 120 4000K

LED, 14 WATT

EXISTING BOX

MOUNT ON

SOFFIT

EXISTING MAIN SERVICE PANEL, TO REMAIN.

MDP

HEIGHT TO MATCH HEIGHT WHEN DEMOLISHED.

WITH RE-CONNECTED EXISTING CABLE PRESERVED IN DEMOLITION. INSTALL AT

NEW RJ-45 COMMUNICATION JACK. PROVIDE IN SURFACE METAL RACEWAY

EXISTING EXTERIOR WALL MOUNTED LIGHT, TO REMAIN.

NEW MOTOR OR MOTOR-OPERATED EQUIPMENT.

P

DEVICE.

ADA COMPLIANT, DUAL ACTION MANUAL FIRE ALARM PULL STATION. INSTALL AT 48" TO TOP OF

XCV

EXISTING MANUAL FIRE ALARM PULL STATION, TO BE REMOVED.

EXISTING FIRE ALARM PANEL, TO REMAIN.

EXISTING WALL MOUNTED FIRE ALARM BELL, TO REMAIN.

EXISTING FIRE ALARM ANTENNA, TO REMAIN. F

K EXISTING FIRE ALARM FIRE DEPARTMENT KEY ACCESS (KNOX) BOX, TO REMAIN.

4000K

LOW LUMEN,

LED, MEDIUM-

#12 AWG, 600 VOLT, THWN COPPER CONDUCTORS IN •" EMT UNO.

EXISTING FIRE ALARM RADIO TRANSCEIVER, TO REMAIN

J

REQUIREMENTS. REFER TO MECHANICAL PLANS FOR ADDITIONAL REQUIREMENTS.

WITHIN SIGHT OF FAN OR MOTOR-OPERATED UNIT. REFER TO MECHANICAL PLANS FOR ADDITIONAL

HORSEPOWER RATED TOGGLE SWITCH. SERVES AS RATED DISCONNECTING MEANS AND SHALL BE LOCATED

FOR DETAILS.

SWITCHES SHALL BE REMOVED TO THE EXTENT NOTED. REFER TO ARCHITECTURAL AND MECHANICAL PLANS EXISTING MOTOR OR MOTOR-OPERATED HVAC OR OTHER EQUIPMENT, TO BE REMOVED. CIRCUITS AND

PRESERVE CABLE FOR USE IN NEW WORK.

EXISTING SURFACE OR FLUSH MOUNTED DATA / TELEPHONE JACK. REMOVE SURFACE BOX AND SURFACE RACEWAY.

LABELING AT BOTH ENDS.

EXISTING SURFACE OR FLUSH MOUNTED DATA / TELEPHONE JACK, TO REMAIN. PROVIDE NEW TESTING AND

FIELD VERIFIED.

DROPS ARE BASED ON AS-BUILT DRAWINGS AND FIELD SURVEY, MAY NOT BE ACCURATE AND SHALL BE BACK TO COMMUNICATION CLOSET. PROVIDE BLANK IVORY COLORED COVER PLATE. EXISTING COMMUNICATION EXISTING COMMUNICATION JACK WITH SUB-STANDARD JACK AND/OR CABLE. REMOVE PLATE, JACK AND CABLE

COVER PLATE, FLUSH MOUNTED IN WALL AT 48" AFF IN LOCATION SHOWN.

NEW 120 / 277 VOLT, 20 AMP, SPECIFICATION GRADE TOGGLE SWITCH WITH IVORY COLORED HANDLE AND

EXISTING PANELBOARD(S), TO REMAIN.

VERIFIED.

ARE BASED ON AS BUILT DRAWINGS AND FIELD SURVEY, MAY NOT BE ACCURATE AND SHALL BE FIELD 120/277 VOLT, 20 AMP SWITCH WITH IVORY COLORED HANDLE AND COVER PLATE. SWITCHES INDICATED HAVE BROWN HANDLE OR BROWN COVER PLATE SHALL BE REPLACED WITH NEW, SPECIFICATION GRADE, EXISTING TOGGLE SWITCH, TO BE REMOVED. EXISTING TOGGLE SWITCH LOCATIONS WHICH REMAIN AND

INTEGRAL TO MAU-1 AND WIRED UNDER THIS PROJECT.

IS INSERTED. BASIS OF DESIGN IS THAT SERVICE RECEPTACLE IS PROVIDED FROM MAU-1 MANUFACTURER, INDICATES A WEATHERPROOF CAST METAL COVER WHICH MAINTAINS ITS RATING WHETHER OR NOT A PLUG DOUBLE SYMBOL REPRESENTS QUAD (DOUBLE DUPLEX) RECEPTACLE. 'G' INDICATES GFCI AND 'WP' COLOR AND HAVE AN IVORY COLORED COVER PLATE. INSTALL FLUSH MOUNTED IN WALL AT 18" AFF UNO.

NEW 120 VOLT, 20 AMP, SPECIFICATION GRADE DUPLEX RECEPTACLE. RECEPTACLE SHALL BE IVORY IN

REPLACEED WITH A NEW IVORY COLORED RECEPTACLE AND COVER PLATE.

QUAD OR DUPLEX RECEPTACLE, EXISTING, TO REMAIN. ALL EXISTING BROWN COLORED, RECEPTACLES SHALL BE

QUAD OR DUPLEX RECEPTACLE, EXISTING, TO BE REMOVED.

NEW 2' X 4' OR 2' X 2' RECESSED GRID CEILING LED FIXTURE. REFER TO LIGHTING FIXTURE SCHEDULE.

SCHEDULE, THIS SHEET.

NEW 1' X 4' WALL OR CEILING SURFACE MOUNT LED LIGHTING FIXTURE. REFER TO LIGHTING FIXTURE

BE REMOVED ARE NOT SHOWN BY SYMBOLS.

LIGHTING FIXTURE, EXISTING, TO BE REMOVED. GRID AND HARD CEILING FIXTURES TO

RST EXISTING FIRE ALARM SMOKE DETECTOR CONTROLS ENCLOSURE, TO REMAIN

OR APPROVED EQUAL.

THROUGH THEM SHALL HAVE EMERGENCY BATTERY BACKUP. COLUMBIA LIGHTING LCAT22 OR LCAT 24 EXTRUDED ACRYLIC ENCLOSED LENS. BALLASTS SHALL BE ELECTRONIC. FIXTURES WITH A SLASH FABRICATION OF THE FIXTURE. THE FIXTURE SHALL BE EQUIPPED WITH A HIGH TRANSMISSION COLD ROLLED STEEL AND FINISHED IN HIGH REFLECTIVITY MATTE WHITE PAINT, APPLIED AFTER CEILING SYSTEM. HOUSING, END CAPS AND REFLECTORS SHALL BE CONSTRUCTED OF CODE GAUGE FIXTURE SHALL BE A RECESSED STATIC LED TROFFER DESIGNED FOR MOUNTING IN A TEE GRID

APPROVED EQUAL. FIXTURES WITH A SLASH SHALL HAVE EMERGENCY BATTERY BACKUP.

FOR INDIRECT LIGHT. FIXTURE SHALL BE 120 VOLT. COLUMBIA CWM4-40MWSM-FRFA-EU-EL114, OR CAPS SHALL BE DIE CAST ALUMINUM FINISHED TO MATCH HOUSING. FIXTURE SHALL BE SET UP PERFORATED STEEL FINISHED IN WHITE POWDER COAT PAINT APPLIED AFTER FABRICATION. END FIXTURE SHALL BE A 4 FOOT SURFACE (WALL) MOUNTED LED FIXTURE, CONSTRUCTED OF HEAVY GRADE

EXISTING BOX)

AFF (OVER

WALL @ 7' 2"

LUMEN, 4000K

LED, LOW

6" DIA. ROUND EXTERIOR, SOFFIT MOUNTED LED FIXTURE

PRESCOLITE 6LCSL14L40K8WHWF OR APPROVED EQUAL.

BE 120 VOLT. ACCESS LIGHTING 50092LEDD OR APPROVED EQUAL.

OPALESCENT GLASS DIFFUSER. NOMINAL FIXTURE DIAMETER SHALL BE 14.5". FIXTURE SHALL

MOUNTING OVER A SINGLE EXISTING BOX. FINISH SHALL BE BRUSHED STEEL WITH AN

FIXTURE SHALL BE AN ARCHITECTURAL CEILING MOUNTED LED FIXTURE DESIGNED FOR SURFACE

LAW2-40LW-EU-PAF OR APPROVED EQUAL.

SHALL BE DESIGNED FOR 120 VOLT OPERATION AND SHALL BE PREWIRED. COLUMBIA LIGHTING

POLYCARBONATE WRAPAROUND DIFFUSER HAVING FLAT BOTTOM AND VERTICAL SIDES. FIXTURE

FINISH APPLIED AFTER FABRICATION. FIXTURE SHALL BE EQUIPPED WITH AN ACRYLIC OR

DIE-FORMED HEAVY GUAGE STEEL AND SHALL BE COATED WITH A WHITE BAKED ON ENAMEL

FIXTURE SHALL BE DESIGNED FOR SURFACE MOUNTING. FIXTURE SHALL BE CONSTRUCTED OF

FIXTURE SHALL BE A LOW PROFILE LED WRAPAROUND WITH NOMINAL FIXTURE LENGTH OF 24".

6.

COMMUNICATION EQUIPMENT, CONDUITS AND AND CABLES.

15. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH DPW CONTRACT INSPECTION BRANCH PRIOR TO AND DURING REMOVAL OF

14. CONTRACTOR SHALL REPLACE ALL ITEMS NOT INDICATED FOR REMOVAL AND REPAIR OR REPLACE ANY DAMAGED ITEMS.

ACCURATE INFORMATION TO CONTRACT INSPECTION BRANCH.

NOTIFY CONTRACT INSPECTION BRANCH OF ANY DISCREPANCY IN BRANCH CIRCUIT PANEL AND CIRCUIT NUMBERS, AND PROVIDE

13. BRANCH CIRCUITS SHOWN ARE BASED ON PLAN DRAWINGS, MAY NOT BE ACCURATE AND SHALL BE FIELD VERIFIED. CONTRACTOR SHALL

12. ALL BRANCH CIRCUITS SHALL HAVE A DEDICATED NEUTRAL CONDUCTOR PROVIDED FOR EACH PHASE CONDUCTOR.

ALL WIRING NO LONGER IN USE SHALL BE REMOVED.

11. CONCEALED CONDUITS NO LONGER IN USE MAY BE ABANDONED IN PLACE. EXPOSED CONDUITS NO LONGER IN USE SHALL BE REMOVED.

MOUNTING IS NOT PRACTICABLE. ALL EXPOSED SURFACE METAL RACEWAY SHALL BE IVORY IN COLOR.

INACCESSIBLE. SURFACE METAL RACEWAY AND SURFACE MOUNTED WIRING DEVICES SHALL BE UTILIZED WHERE FLUSH

CEILING, WHERE PRACTICABLE. WIRING DEVICES SHALL BE FLUSH MOUNTED WHERE PRACTICABLE. NO WIRING SPLICES SHALL BE

10. BRANCH CIRCUITS, LIGHTING CIRCUITS AND COMMUNICATION CIRCUITS SHALL BE CONCEALED INSIDE FINISHED WALLS AND ABOVE

ARE EXISTING TO BE REMOVED OR TO REMAIN MAY NOT BE SHOWN ON THESE DRAWINGS AND SHALL BE FIELD VERIFIED.

9. SOME RECEPTACLES, LIGHTS, SWITCHES, TELEPHONE / COMMUNICATION RECEPTACLES, CONDUIT, BOXES AND OTHER DEVICES WHICH

8. ALL PIPING, RACEWAY AND OUTLET BOXES SHALL BE CONSTRUCTED OF NON-COMBUSTIBLE MATERIAL.

THE PASSAGE OF FLAMES AND HOT GASSES. THE SEALANT SHALL HAVE A T-RATING OF ONE HOUR.

7. ALL WALL AND CEILING PENETRATIONS SHALL BE SEALED WITH A MATERIAL (PAINTABLE FIRE CAULK) CAPABLE OF PREVENTING

AWG SIZE IS SPECIFIED.

6. A GREEN JACKETED #12 THWN GROUNDING CONDUCTOR SHALL BE INCLUDED IN ALL CIRCUITS, EXCEPT WHERE USE OF LARGER

BRANCH CIRCUITS SHALL CONSIST OF AWG 12 THWN COPPER CONDUCTORS IN IVORY COLORED SURFACE METAL RACEWAY, UNO.

5. CONCEALED BRANCH CIRCUITS SHALL CONSIST OF AWG 12 THWN COPPER CONDUCTORS IN 1/2" EMT, UNO. SURFACE MOUNTED

4. PROTECT THE STRUCTURE, FURNISHINGS, FINISHED AND ADJACENT MATERIALS NOT INDICATED OR SCHEDULED TO BE REMOVED.

3. CONTRACTOR SHALL MAINTAIN CONTINUITY OF CIRCUITS IN CASES WHERE IT FEEDS OTHER AREAS TO REMAIN AS IS.

SPECIFIED AS BEING TURNED OVER TO THE GOVERNMENT OR NOT USED IN NEW WORK.

2. ANY ELECTRICAL EQUIPMENT, ASSOCIATED WIRE AND CONDUITS WHICH ARE REMOVED, SHALL BE LEGALLY DISPOSED OF, IF NOT

1. ALL WORK MUST SHALL PERFORMED IN STRICT ACCORDANCE WITH NFPA 70, NFPA 72 AND NFPA 101.

EMT ELECTRICAL METALLIC TUBING

C8107.27

J

L

E

2017-04-24T12:23:30-0500
BALES.JIMMIE.D.JR.1231309302

File details come from the government source that posted it. Updated .