8107_m7v8.pdf

PDF 166 KB Posted

Attached to
Renovation of Builiding 1701
Solicitation number
W911S717B0003
Issued by

About this file

8107_m7v8, 14 of 27

View the file

Other files

File Type Posted
Bid_Abstract,_W911S7-17-B-0003.pdf PDF
Additional_Questions_W9111S7-17-B-0003.pdf PDF
W9111S7-17-B-0003,_Repair_and_Renovation_of_Bldg_1701,_Amendment_0002.pdf PDF
Revised,_8107_mi7v8.pdf PDF
Questions_and_Answers_W911S7-17-B-0003.pdf PDF
Revised,_8107_mi6v8.pdf PDF
W911S7-17-B-0003,_Repair_Renovation_of_Bldg_1701,_Admendment_0001.pdf PDF
Revised,_8107_mi9v8.pdf PDF
Revised,_8107_mi10v8.pdf PDF
Revised,_8107_m3v8.pdf PDF
Site_Visit_Roster.pdf PDF
8107_mi6v8.pdf PDF
8107_mi11v8.pdf PDF
Attachment_B,_DBA_Wages_MO170019.pdf PDF
W911S7-17-B-0003_Repair_Renovation_of_Bldg_1701.pdf PDF
8107_m6v8.pdf PDF
8107_m8v8.pdf PDF
8107_e3v8.pdf PDF
8107_a1v8.pdf PDF
8107_m2v8.pdf PDF
8107_mi12v8.pdf PDF
8107_mi10v8.pdf PDF
8107_mi3v8.pdf PDF
8107_mi2v8.pdf PDF
8107_e1v8.pdf PDF
Attachment_A,_Statement_of_Work.pdf PDF
8107_a2v8.pdf PDF
8107_e4v8.pdf PDF
Technical_Exhibit_1,__1701_Asbestos_Report.pdf PDF
8107_mi4v8.pdf PDF
8107_m3v8.pdf PDF
8107_m1v8.pdf PDF
8107_mi1v8.pdf PDF
8107_mi5v8.pdf PDF
8107_mi8v8.pdf PDF
8107_m4v8.pdf PDF
8107_e2v8.pdf PDF
8107_a3v8.pdf PDF
8107_mi9v8.pdf PDF
8107_m5v8.pdf PDF
8107_mi7v8.pdf PDF
Show all 41

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L v

O f

A P

P R

D M

A D

E

D I

R E

C T

O R

A T

E

O F

U

B L I

C

W

R K

S

F O

R

O N

A

D

W

O

M

S S

O U

R I

D E

S C

R I

P T I

O N

R E

V I

S I

O N

S

D A

T E

A P

P R

O V

E D

D A

T E

S U

B M I

T T

E D

C H

E C

K E

D

D R

A W

N

D E

S I

G N

E D

C O

O R

D I

N A

T I

O N

D A

T E

D A

T E

D A

T E

SCALE

DATE

PROJECT NO:

DRAWING NO:

OFSHEET

AS SHOWN

E L

L E

E L

L E

E L

L E

R

F

S

M C

R E

P A

B

I

L D I

N G

17 NOV 16

DPW 03383-6J

Y L

O R

N O

R

H

4 2 0 4 8

S C A L E I N F E E T

PLUMBING PLAN - DEMOLITION

N O

R

H

4 2 0 4 8

S C A L E I N F E E T

PLUMBING PLAN - NEW WORK

KEYED NOTES

GENERAL NOTES, DEMOLITION

ITEMS TO BE REMOVED ARE INDICATED AS DOTTED LINES

OF ALL SUPPORTS, BRACKETS, AND/OR HANGERS.

REMOVAL/DEMOLITION OF ANY ITEM (EQUIPMENT, DUCT, PIPING, ETC.) SHALL INCLUDE THE REMOVAL/DEMOLITION 5.

ANY DEBRIS SHALL BE REMOVED FROM WORK AREAS DAILY.

KEEP CLEAN ALL EXISTING SPACES AND PROPERTIES ADJACENT TO DEMOLITION/ CONSTRUCTION AREAS. 4.

PROTECT FROM DAMAGE ALL PORTIONS OF THE EXISTING BUILDING DURING DEMOLITION/ CONSTRUCTION.3.

OF ANY DISCREPANCIES.

VERIFY FIELD CONDITIONS PRIOR TO START OF DEMOLITION/ CONSTRUCTION, AND NOTIFY THE GOVERNMENT 2.

REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL SHEETS FOR ADDITIONAL INFORMATION.1.

KEYED NOTES

GENERAL NOTES:

1. ALL COLD AND HOT WATER PIPING SHALL BE TYPE-L COPPER AND SLOPED

1/4"/ FT.

2. SEE ARCHITECTUAL, MECHANICAL, CIVIL & ELECTRICAL SHEETS FOR ADDITIONAL

INFO.

3. THE MENTION OF A BRAND NAME IS NOT INTENDED TO LIMIT COMPETITION BUT

IS USED AS A QUALITY STANDARD ONLY.

4. 2012 INTERNATIONAL PLUMGING CODE SHALL APPLY.

5. SUBMITTALS REQUIRED ON ALL MATERIALS.

6. ALL WATER PIPING SHALL HAVE FIBER INSULATION COMPLETELY SEALED

WITH ASJ. INCLUDE PVC JACKET COVERS AT FITTINGS. COLD WATER SHALL HAVE

MOLDED INSULATION UNDER PVC JACKET AT FITTINGS. PROVIDE LABELING AND

DIRECTION ARROWS.

7. WALL PENETRATIONS SHALL INCLUDE CHROME ESCUTCHENS.

8. PIPE HANGERS AND SUPPORTS SHALL BE NONMETALLIC AT CONNECTION TO PIPING

9. MECHANICAL ROOM PENETRATIONS SHALL BE 2-HOUR FIRE SEALED.

WALL

ESCUTCHENS

WALL

BALL VALVE

SUPPLY SHUTOFF

…" COLD WATER

ELECTRIC WATER COOLER

P-TRAP,

1-1/4" WASTE

N.T.S.

M A

X

A F

F

M I N

A F

F

TYPICAL

VALVE

BALL

SHUTOFF

SUPPLY

WATER

AND COLD

3/8" HOT

WITH P-TRAP

1-1/4" WASTE

SUPPLY

WATER

HOT

SUPPLY

WATER

COLD

DETAIL ADA CLEARANCES REQUIRED

LAVATORY FRONT AND SIDE VIEW

WALL

FLOOR

ESCUTCHENS

WALL

FILLER

BOTTLE

N.T.S.

7.7 GPH AT 50 DEGREES F.

FILTER AND BOTTLE FILLER.

ADA APPROVED UNIT INCLUDES LEAD

CL

FROM FINISHED FLOOR TO SEAT.

ADA SEAT HEIGHT REQUIRED. 17"-19"8.

WATER SUPPLY SHALL BE 1".7.

CAPS.

COMPLETE WITH FLOOR BOLTS AND BOLT 6.

GASKET SHALL BE WAX TYPE.5.

PROVIDE CLOSET FLANGE.4.

LESS COVER.

SEAT SHALL BE BLACK, OPEN FRONT 2.

SAVING FLUSHOMETER VALVE.

WATER SAVER TOILET WITH WATER

WATER CLOSET SHALL BE ELONGATED 1.

W.C. OUTLET

N.T.S.ADA WATER CLOSET DETAIL

REMOVE DRINKING WATER FOUNTAIN COMPLETE AND PREPARE WALL AND PLUMBING FOR NEW FOUNTAIN.4.

SHALL BE CAPPED OR PLUGGED INSIDE WALL. REPAIR WALL TO MATCH ADJACENT.

REMOVE URINAL COMPLETE TO INCLUDE ALL PLUMBING. DOMESTIC WATER PIPING SHALL BE CAPPED AT THE MAIN. WASTE 3.

REMOVE WATER CLOSET COMPLETE TO INCLUDE EXPOSED WATER PIPING AND STOP VALVE.2.

REMOVE LAVATORY COMPLETE TO INCLUDING ALL EXPOSED PLUMBING PIPING AND STOP VALVES.1.

PROVIDE ADA DRINKING WATER COOLER.3.

PROVIDE ADA WATER CLOSET COMPLETE TO INCLUDE PIPING AND FLUSH VALVE.2.

PIPING AND ADA PIPING INSULATION.

PROVIDE ADA LAVATORY COMPLETE WITH STOP VALVES, HOT & COLD SUPPLY LINES, DRAIN 1.

PROVIDE CARRIER PER SPECIFICATION.6.

LOCATED AND INSULATED PER ADA.

UNDER SINK PIPING SHALL BE BRASS WITH CHROME FINISH5.

CHROME WALL ESCUTCHEN FOR ALL WALL PIPE PENATRATIONS.4.

FAUCET/VALVE FLEXIBLE STAINLESS CONNECTORS.3.

PROVIDE LAVATORY STOP VALVES. 2.

BLADE HANDLES, CHROME TUBING TAILPIECE, AND STRAINER.

ADA LAVATORIES INCLUDE ADA GOOSE NECK FAUCET AND WRIST 1.

T A I

L S

P L

U M

B I

N G

A N

M7 8

J

B

L

S

C

E D

B

C8107.27

RESTROOM RESTROOM

STORAGE

JANITOR

MOP

EWC

OF SHELVES

FIVE ROWS

2017-04-24T12:31:25-0500
BALES.JIMMIE.D.JR.1231309302

File details come from the government source that posted it. Updated .