8107_mi5v8.pdf
PDF 142 KB Posted
- Attached to
- Renovation of Builiding 1701
- Solicitation number
- W911S717B0003
About this file
8107_mi5v8, 20 of 27
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L v
O f
A P
P R
D M
A D
E
D I
R E
C T
O R
A T
E
O F
U
B L I
C
W
R K
S
F O
R
O N
A
D
O
M
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
AS SHOWN
E L
L E
G
S T
E N
S T
E
J
L L
A R
D I
SHEET MI5 OF12
F
S
M C
R E
P A
B
I
L D I
17 NOV 16
DPW 03383-6J
DDC
HW-PMP-SS
L1
L2
L3
FUSE
X1
CIRCUIT BREAKER
XMFR
X2
CT
DDC
AUTO
HAND
OFF MS-1
OL'S
PUMP MOTOR
M1
HW-PMP-S
DDC
CW-PMP-SS
L1
L2
L3
FUSE
X1
CIRCUIT BREAKER
XMFR
X2
CT
DDC
AUTO
HAND
OFF MS-1
OL'S
PUMP MOTOR
M1
CW-PMP-S
HW PUMP LADDER DIAGRAM
CW PUMP LADDER DIAGRAM
SEQUENCE OF OPERATIONS/ LADDER DIAGRAMS
L2
FUSE
X1
L1
XMFR
X2
V-1
HX-DP-LL
HTHW ACTUATOR
TO:
DDC-##
HIGH TEMPERATURE HOT WATER ACTUATOR SAFETY
TO MAINTAIN DIFFERENTIAL PRESSURE.
COMMAND(CW-PMP-SS) THE CHILLED WATER PUMP ON AND THE SPEED SHALL MODULATE
D. CHILLED WATER PUMP CONTROL: WHEN THIS LOOP IS ENABLED THE DDC HARDWARE SHALL
(3) SAFETIES: NONE
CHILLED WATER PUMP STATUS (CW-PMP-S)
(2) PROOFS:
(1) DDC HARDWARE SHALL MONITOR PROOFS AND SAFETIES.
C. PROOFS AND SAFETIES
(3) WHEN THE OUTDOOR AIR TEMPERATURE IS 64°F OR BELOW THIS SYSTEM SHALL BE DISABLED.
BE ENABLED COOLING MODE. THE OUTDOOR AIR TEMPERATURE CHANGEOVER SHALL HAVE A 2 DEGREE F DEADBAND.
(2) WHEN THE OUTDOOR AIR TEMPERATURE IS 66°F OR ABOVE AND A COOLING REQUEST THIS SYSTEM SHALL
(1) THIS SYSTEM SHALL MONITOR THE OUTDOOR AIR TEMPERATURE.
B. SYSTEM ENABLE AND LOOP ENABLE
BE UNDER CONTROL OF THE DDC SYSTEM..
TO THE CHILLED WATER PUMP START/STOP COMMAND (CW-PMP-SS) AND SAFETIES AND
(3) AUTO: WITH THE H-O-A SWITCH IN AUTO POSITION, THE CHILLED WATER PUMP SHALL RUN SUBJECT
(2) OFF: WITH THE H-O-A SWITCH IN THE OFF POSITION, THE CHILLED WATER PUMP SHALL STOP.
RUN CONTINUOUSLY, SUBJECT TO SAFETIES.
(1) HAND: WITH THE H-O-A SWITCH IN HAND POSITION, THE CHILLED WATER PUMP SHALL START AND
CHILLED WATER PUMP VFD SHALL HAVE AN INTEGRAL H-O-A SWITCH:
A. HAND-OFF-AUTO SWITCHES:
SPECIFIED, ALL MODULATING CONTROL SHALL BE PROPORTIONAL-INTEGRAL (PI) CONTROL.
INPUTS, OUTPUTS AND ALARMS AS SPECIFIED AND SHOWN ON THE POINTS SCHEDULE. UNLESS OTHERWISE
CONTRACTOR SHALL INSTALL DDC HARDWARE TO PERFORM THIS SEQUENCE OF OPERATION AND TO PROVIDE SNVT
CHILLED WATER CONTROL
EXCHANGER SAFETY SWITCH(HX-P-LL). WHEN THIS LOOP IS DISABLED THE VALVE SHALL BE CLOSED.
A LINEAR RESET SCHEDULE AS SHOWN. THE DDC HARDWARE SHALL MONITOR THE STATUS OF THE HEAT
(HWS-T) AT SETPOINT(HWS-T-SP). THE HOT WATER SUPPLY TEMPERATURE SETPOINT SHALL BE DETERMINED FROM
TEMPERATURE
SHALL MODULATE THE HIGH TEMPERARURE HOT WATER VALVE TO MAINTAIN THE THE HOT WATER SUPPLY
HEAT EXCHANGER AS SENSED BY THE DIFFERENTIAL PRESSURE SWITCH(HX-P-LL) SAFETY, THE DDC HARDWARE
D. HEAT EXCHNGER VALVE CONTROL: WHEN THIS LOOP IS ENABLED AND THERE IS WATER FLOW THROUGH THE
HIGH TEMPERATURE HOT WATER VALVE.
HEAT EXCHANGER DIFFERENTIAL PRESSURE SWITCH(HX-P-LL) SHALL BE DIRECT-HARDWIRE INTERLOCKED TO THE
(3) SAFETIES:
HEATING WATER PUMP STATUS (HW-PMP-S)
(2) PROOFS:
(1) DDC HARDWARE SHALL MONITOR PROOFS AND SAFETIES.
C. PROOFS AND SAFETIES
EXCHANGER CONTROL LOOP SHALL BE ENABLED.
(3) WHEN THIS SYSTEM IS ENABLED(SYS-ENA) AND THE HOT WATER PUMP IS PROOFED ON, THE HEAT
(2) WHEN THE OUTDOOR AIR TEMPERATURE IS 65°F OR BELOW THIS SYSTEM SHALL BE IN HEATING MODE.
(1) THIS SYSTEM SHALL MONITOR THE OUTDOOR AIR TEMPERATURE.
B. SYSTEM ENABLE AND LOOP ENABLE
CONTROL OF THE DDC SYSTEM. PUMP SPEED SHALL MODULATE TO MAINTAIN DIFFERNTIAL PRESSURE SETTING.
SUBJECT TO THE HEATING WATER PUMP START/STOP COMMAND (HW-PMP-SS) AND SAFETIES AND BE UNDER
(3) AUTO: WITH THE H-O-A SWITCH IN AUTO POSITION, THE HEATING WATER PUMP SHALL RUN
(2) OFF: WITH THE H-O-A SWITCH IN THE OFF POSITION, THE HEATING WATER PUMP SHALL STOP.
RUN CONTINUOUSLY, SUBJECT TO SAFETIES.
(1) HAND: WITH THE H-O-A SWITCH IN HAND POSITION, THE HEATING WATER PUMP SHALL START AND
HEATING WATER PUMP VFD SHALL HAVE AN INTEGRAL H-O-A SWITCH:
A. HAND-OFF-AUTO SWITCHES:
SPECIFIED, ALL MODULATING CONTROL SHALL BE PROPORTIONAL-INTEGRAL (PI) CONTROL.
INPUTS, OUTPUTS AND ALARMS AS SPECIFIED AND SHOWN ON THE POINTS SCHEDULE. UNLESS OTHERWISE
CONTRACTOR SHALL INSTALL DDC HARDWARE TO PERFORM THIS SEQUENCE OF OPERATION AND TO PROVIDE SNVT
HEATING HOT WATER FROM DISTRIBUTED HTHW CONVERTER
VFD
VFD
D D
A G
R A
M S
S E
Q U
E N
F
E R
A T I
O
H
H I
L L
T E
R
J
L
E D
C8107.27