8107_m1v8.pdf
PDF 418 KB Posted
- Attached to
- Renovation of Builiding 1701
- Solicitation number
- W911S717B0003
About this file
8107_m1v8, 8 of 27
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L v
O f
A P
P R
D M
A D
E
D I
R E
C T
O R
A T
E
O F
U
B L I
C
W
R K
S
F O
R T
L
O N
A
D
W
O
M
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
OFSHEET
AS SHOWN
F
S
M C
R E
P A
B
I
L D I
N G
17 NOV 16
DPW 03383-6J
GENERAL NOTES
9.
8.
7.
6.
5.
4.
3.
2.
1.
GENERAL NOTES - HVAC
ALL DUCTS SHALL BE CONSTRUCTED AND ERECTED IN A NEAT
AND WORKMANLIKE MANNER.
DUCTS SHALL BE CONSTRUCTED OF THE WEIGHTS, GAGES AND
MATERIAL SHOWN IN THE SPECIFICATIONS AND ACCORDING TO
THE DIMENSION SHOWN FOR ALL DUCTS SHOWN IN PLAN GIVE
THE WIDTH FIRST AND THEN THE HEIGHT.
DUCT RISERS SHOULD BE SUPPORTED BY ANGLES AT EVERY
FLOOR.
AIR TURNING VANES SHALL BE INSTALLED IN ALL ABRUPT ELBOWS
TO PREVENT TURBULENCE.
DUCTS SHALL BE SECURELY ATTACHED TO THE BUILDING
CONSTRUCTION IN AN APPROVED MANNER.
DIVERGING TRANSITION PIECES SHALL BE MADE AS GRADUAL
AS POSSIBLE.
DUCT AREA SHALL NOT BE DECREASED MORE THAN 10
PERCENT WHEN OBSTRUCTIONS CANNOT BE AVOIDED, AND
THEN A STREAMLINED FITTING SHOULD BE USED.
JOINTS AND SEAMS OF SUPPLY DUCTS SHALL BE FASTENED
SECURELY AND SEALED PER SPECIFICATIONS FOR DUCT PRESSURE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
FLEXIBLE FABRIC CONNECTIONS (OR EQUAL) SHALL BE
USED ON BOTH INLETS AND OUTLETS OF ALL FANS AND
AIR HANDLING UNITS.
CLASS AND LEAKAGE CLASS.
SMACNA.
UNION - SCREWED OR FLANGED
STRAINER WITH BLOW OFF VALVE
PIPE DROPPING DOWN
PIPE RISING UP
DIRECTION OF PITCH-RISE OR DROP
DIRECTION OF FLOW
RELIEF/SAFETY VALVE
FLOW METER-VENTURI
FLOW METER-ORIFICE
FUSIBLE LINK VALVE-QUICK CLOSING
FUSIBLE LINK VALVE-QUICK OPENING
AUTOMATIC AIR VENT (EXTEND
AUTOMATIC FILL VALVE
DISCHARGE TO DRAIN)
MANUAL AIR VENT
CONCENTRIC REDUCER
ECCENTRIC REDUCER
MECHANICAL PIPING ELEMENTS/VALVING
TPV
S
RELIEF VALVE
PRESSURE REDUCING VALVE (PRV)
CIRCUIT SETTING BALANCING VALVE
SOLENOID VALVE
TWO WAY CONTROL VALVE
TEMPERATURE/PRESSURE
DIAPHRAM VALVE
BALANCING VALVE
THREE WAY CONTROL VALVE
CBV
R D
STRAINER
EXISTING EQUIPMENT OR PIPING
LIFT CHECK VALVE
SWING CHECK VALVE
GATE VALVE
TO BE REMOVED UNLESS NOTED OTHERWISE
BUTTERFLY VALVE
PLUG VALVE
GLOBE VALVE
MV
AV
GAS COCK
AQUASTAT
FLOAT OPERATED CONTROL VALVE
W
VB
H
VACUUM BREAKER
EXPANSION LOOP (WxH)
GAS PRESSURE REGULATOR
BASKET STRAINER
ANCHOR
EJ
TT
FS
TH
PT/PS
G
PRESSURE SWITCH
& SYPHON (STEAM)
GAUGE WITH GAUGE COCK
PRESSURE TRANSMITTER OR
THERMOMETER
EXPANSION JOINT
TEMPERATURE TRANSMITTER
FLOW SWITCH
GUIDE
A
RETURN AIR
OUTSIDE AIR
NUMBER
NUMBER
SINGLE LINE
SIZE
CFM
CFM
SIZE
SUPPLY AIR
RADIUS ELBOW (R=1.5)
CONTROL DAMPER-
PARALLEL BLADE
OPPOSED BLADE
CONTROL DAMPER-
GRILLE (G) OR REGISTER (R)
RETURN AND/OR EXHAUST AIR
AIR REGISTER (R)
SUPPLY AIR GRILLE (G) OR SUPPLY
CFM
SIZE
NUMBER
SIZE
CFM
NUMBER
FLEXIBLE CONNECTION (FXC)
BRANCH DUCT TAKE-OFF
VANED ELBOW
MOTOR OPERATED DAMPER (MD)
MANUAL VOLUME DAMPER (MVD)
NEW DUCTWORK
EXISTING DUCTWORK TO BE REMOVED
VD
DOUBLE LINE
DUCTWORK SYMBOLS
VD
AUTOMATIC BALANCING VALVE
ABV
TEMPERATURE SENSOR
HUMIDITY SENSOR
T
H
REFRIGERANT DETECTORR
EXHAUST AIR
HWS
HWR HOT WATER RETURN
HOT WATER SUPPLY
MECHANICAL LINE DESIGNATION SYMBOLS
CWS
CWR
CHILLED WATER SUPPLY
CHILLED WATER RETURN
DUCT CAP
LAMB'S TOUNGE
POINT OF CONNECTION
POINT OF DEMOLITION
MU MAKE-UP WATER
CD CONDENSATE DRAIN
GENERAL SYMBOLS
CONTRACTING OFFICER'S REPRESENTATIVEC.O.R.
FIRE DAMPER
FIRE/SMOKE DAMPERF/S
DTS
DTR DUAL TEMPERATURE WATER RETURN
DUAL TEMPERATURE WATER SUPPLY
MW MAKE UP WATER
HOT WATER CIRCULATION
COLD WATER
HOT WATER
SANITARY SEWER
RD ROOF DRAIN
VENT THRU ROOF
VENT
VTR
VTR
OCCUPANCY SENSOROS
MOTORIZED DAMPERM
HTWS
HTWR
HIGH TEMP WATER SUPPLY
HIGH TEMP WATER RETURN
M1
G
S T
E N
S T
E N
J
L L
A R
D
E L
L E
R
L E
G E
N D
WITH NEW, EXISTING, OR TEMPORARY HVAC EQUIPMENT AS REQUIRED.
PROTECTED FROM FREEZING. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN THIS CONDITION
CONTRACTOR SHALL PHASE ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SO BUILDING IS
CONTENTS LABELING AND DIRECTION ARROWS.
ALL EXPOSED, INSULATED INTERIOR PIPING IN OCCUPIED AREAS SHALL HAVE PVC JACKET. PROVIDE
ALL DRAINS SHALL CONNECT TO FLOOR DRAIN, JANITORS SINK, OR APPROVED RECEPTOR.
VENTS SHALL BE PIPED TO DRAIN. PROVIDE DRAINAGE VALVES AT LOW POINTS IN EACH SYSTEM.
INSTALL AUTOMATIC AIR VENTS AT HIGH POINTS IN ALL HYDRONIC SYSTEMS. DISCHARGE FROM AIR
WALL OR FLOOR.
WITH REQUIREMENTS OF THE MANUFACTURER TO MAINTAIN THE FIRE RATING OF THE PENETRATED
SILICONE RTV FOAM, OR APPROVED EQUAL. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE
ACCEPTED AS BEING SUITABLE FOR THIS SERVICE, SUCH AS HILTI SILICONE ELASTOMER, HILTI
THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS UL LISTED AND
WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS OR WALLS, MATERIALS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RIGGING, HANDLING AND PROTECTION OF
CONTRACTOR SHALL COORDINATE ALL WORK WITH THE C.O.R. AND ALL OTHER CONTRACTORS.
PORTIONS OF THE BUILDING THAT MUST REMAIN IN OPERATION DURING CONSTRUCTION.
CONTRACTOR SHALL SCHEDULE WITH C.O.R. ALL SHUTDOWNS THAT AFFECT UTILITIES AND
COMPLETE INSTALLATION.
INSTRUCTIONS. THE CONTRACTOR SHALL PROVIDE ALL HANGERS AND SUPPORTS REQUIRED FOR A
ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN
ORDINANCES.
ALL WORK SHALL CONFORM TO ALL STATE AND LOCAL CODES, RULES AND REGULATIONS AND