8107_m5v8.pdf
PDF 129 KB Posted
- Attached to
- Renovation of Builiding 1701
- Solicitation number
- W911S717B0003
About this file
8107_m5v8, 12 of 27
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L v
O f
A P
P R
D M
A D
E
D I
R E
C T
O R
A T
E
O F
U
B L I
C
W
R K
S
F O
R
O N
A
D
W
O
M
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
OFSHEET
AS SHOWN
E L
L E
R
F
S
M C
R E
P A
B
I
L D I
N G
17 NOV 16
DPW 03383-6J
AHU-E AHU-D AHU-C AHU-AAHU-B
HWR HWR HWR HWR
HWRHWR
HWS HWS
HWSHWSHWSHWS
CWS
CWR
CWS CWS CWS CWS
CWR CWRCWR
N O
R
H
4 2 0 4 8
S C A L E I N F E E T
N O
R
4 2 0 4 8
S C A L E I N F E E T
HOT WATER PIPING PLAN
CHILLED WATER PIPING PLAN
MAU-1
1/2"** (TYPICAL FOR ALL FAN COIL UNITS)
MODULES (A THRU E).
PROVIDE 1/2" SUPPLY AND RETURN TO EACH FAN COIL UNIT (FCU1, FCU-2, FCU-3, FCU-4 & FCU-5). APPLIES TO ALL **
PROVIDE 3/4" SUPPLY AND RETURN TO EACH AIR HANDLER UNIT (AHU-A THRU AHU-E). ***
2" 2"2"2"
1-1/2"
1-1/2" 1"
1" 1"
1-1/2"
1-1/2"1-1/2"2" 2"
2-1/2"
2"
1" 1"1-1/2"1-1/2"1-1/2"1"
CWRCWR
CWS
2-1/2"
FCU-1(A)
FCU-4(A)
FCU-5(A)
FCU-2(A)
FCU-1(B)
FCU-3(A)
FCU-4(B)
FCU-5(B)
FCU-2(B)
FCU-3(B)
FCU-2(C)
FCU-3(C)
FCU-1(C) FCU-1(D)
FCU-4(D)
FCU-4(C)
FCU-5(C) FCU-5(D)
FCU-3(D)
FCU-2(D) FCU-2(E)
FCU-3(E)
FCU-1(E)
FCU-4(E)
FCU-5(E)
FCU-1(A)
FCU-4(A)
FCU-5(A)
FCU-2(A)
FCU-1(B)FCU-3(A)
FCU-4(B)
FCU-5(B)
FCU-2(B)
FCU-3(B)
FCU-2(C)
FCU-3(C)
FCU-1(C) FCU-1(D)
FCU-4(D)FCU-4(C)
FCU-5(C) FCU-5(D)
FCU-3(D)
FCU-2(D) FCU-2(E)
FCU-3(E) FCU-1(E)
FCU-4(E)
FCU-5(E)
MAU-1
W A
T
P I
A N
S
H
I
L L
E
S T
E
S T
E
J
L L
A R
D I
M5 8
AHU (A THRU E) ARE DX UNITS WITH HEAT PUMP CONDENSING UNITS ON ROOF AND THEREFORE GET NO CHILLED WATER.
H W
SH
W
R C
W R
C W
S
TO MECHANICAL ROOM
TO MECHANICAL ROOM
3/4"*** (TYPICAL FOR ALL AIR HANDLER UNITS)
ALL CONTROL VALVES TO BE 2-WAY EXCEPT FCU-4(A) AND FCU-4(E) SHALL HAVE 3-WAY VALVES
ALL CONTROL VALVES TO BE 2-WAY EXCEPT FCU-4(A), FCU-4(E) AND AHU-C SHALL HAVE 3-WAY VALVES
DP DP
DP - PLACE DIFFERENTIAL PRESSURE SENSOR BETWEEN SUPPLY AND RETURN AT THESE LOCATIONS
DP DP
DP - PLACE DIFFERENTIAL PRESSURE SENSOR BETWEEN SUPPLY AND RETURN AT THESE LOCATIONS
6'
3'
6'
3'
8'
4'
4'
2'
4'
2'
1/2"** (TYPICAL FOR ALL FAN COIL UNITS)
MAU-1
1-1/4" TO
PREHEAT COIL
3/4" TO MAU-1
REHEAT COIL
3/4" TO MAU-1
J
L
S
E D
C8107.27