8107_mi1v8.pdf
PDF 179 KB Posted
- Attached to
- Renovation of Builiding 1701
- Solicitation number
- W911S717B0003
About this file
8107_m1v8, 16 of 27
View the file
Other files
Show all 41
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L v
O f
A P
P R
D M
A D
E
D I
R E
C T
O R
A T
E
O F
U
B L I
C
W
R K
S
F O
R T
O N
A
D
W
O
M
S S
O U
R I
D E
S C
R I
P T I
O N
R E
V I
S I
O N
S
D A
T E
A P
P R
O V
E D
D A
T E
S U
B M I
T T
E D
C H
E C
K E
D
D R
A W
N
D E
S I
G N
E D
C O
O R
D I
N A
T I
O N
D A
T E
D A
T E
D A
T E
SCALE
DATE
PROJECT NO:
DRAWING NO:
OFSHEET
AS SHOWN
E L
L E
R
17 NOV 16
DPW 03383-6J
PH
PC
H
HC
DX
C
CONTACT, PRESSURE, LOW LIMIT (LL)
CONTACT, PRESSURE, LOW LIMIT (LL)
SEE "ACTUATOR, PNEUMATIC"
P
PP
CONTACT, PRESSURE, HIGH LIMIT (HL)
CONTACT, PRESSURE, HIGH LIMIT (HL)
COIL, HEAT/COOL (DUAL TEMPERATURE)
VDC OR mA INPUT / 3-15 PSI OUTPUT
(WHEN MORE THAN 1 EPS)
(WHEN MORE THAN 1 EP)
EP
RELAY COIL CONTACT
RELAY COIL CONTACT
CONTROL SCHEMATIC SYMBOLS
P
P
M
PP
ACTUATOR, ELECTRIC
IN DAMPER SCHEDULE
RELAY COIL
M#
IN DAMPER SCHEDULE
DAMPER, BALANCING
## : DEVICE NUMBER
OUTPUT IS ALWAYS SAFETY INTERLOCK
DEVICE SYMBOL, CONTROLLER
GENERIC USAGE TO SHOW LOCATION OF DEVICE;
CLOSED WHEN TEMPERATURE IS ABOVE SETPOINT
CLOSED WHEN TEMPERATURE IS ABOVE SETPOINT
CLOSED WHEN TEMPERATURE IS BELOW SETPOINT
CLOSED WHEN TEMPERATURE IS BELOW SETPOINT
COM = COMMON PORT
IN VALVE SCHEDULE
## = VALVE NUMBER AS SHOWN
NO = NORMALLY OPEN
COM = COMMON PORT
NO = NORMALLY OPEN
IN VALVE SCHEDULE
## = VALVE NUMBER AS SHOWN
NC
NO
NC
IN VALVE SCHEDULE
IN VALVE SCHEDULE
## = VALVE NUMBER AS SHOWN
## = VALVE NUMBER AS SHOWN
NO
NO
NC
THERMOWELL IN PIPE
TEMPERATURE SENSOR, POINT
T
P
H L
(WHEN MORE THAN 1 LDP)##
GENERIC USAGE TO SHOW LOCATION OF DEVICE;
EH
DEVICE SYMBOL, GENERIC
USED TO REPRESENT SENSORS, INSTRUMENTS
SAFETIES, AND OTHER CONTROL DEVICES
W-X-Y-Z : (SEE ABBREVIATIONS AND ACRONYMS)
PROCESS OR DEVICE BEING MEASURED OR
CONTROLLED; SIGNAL TYPE; MODIFIERS AND
OTHER APPLICATION INFORMATION
W-X-Y-Z MULTIPLE OUTPUT DEVICE WHERE AT LEAST 1
DEVICE SYMBOL, GENERIC
DDC : DIRECT DIGITAL CONTROL
DIR : DIRECT CONTROL ACTION, OR
REV : REVERSE CONTROL ACTION
W-X-Y-Z : (SEE ABBREVIATIONS AND ACRONYMS)
PROCESS OR DEVICE BEING MEASURED OR
CONTROLLED; SIGNAL TYPE; MODIFIERS AND
OTHER APPLICATION INFORMATION
DIR
REV
DDC
W-X-Y-Z
W-X-Y-Z
CLOSED WHEN PRESSURE IS ABOVE SETPOINT
OPEN WHEN PRESSURE IS BELOW SETPOINT
SHOWN IN UNACTIVATED POSITION
CONTACT, TEMPERATURE, HIGH LIMIT (HL)
SHOWN IN ACTIVATED POSITION
OPEN WHEN TEMPERATURE IS ABOVE SETPOINT
CONTACT, TEMPERATURE, HIGH LIMIT (HL)
SHOWN IN UNACTIVATED POSITION
OPEN WHEN TEMPERATURE IS ABOVE SETPOINT
CONTACT, TEMPERATURE, LOW LIMIT (LL)
SHOWN IN ACTIVATED POSITION
OPEN WHEN TEMPERATURE IS BELOW SETPOINT
CONTACT, TEMPERATURE, LOW LIMIT (LL)
SHOWN IN UNACTIVATED POSITION
OPEN WHEN TEMPERATURE IS BELOW SETPOINT
CONTROL SIGNAL LINE, LOW VOLTAGE
CURRENT TRANSFORMER/SWITCH
PRESSURE GAGE
AND LOCALLY MOUNTED
WITH POSITIVE POSITIONER
ACTUATOR, PNEUMATIC
PRESSURE GAGE
WITH LOCALLY MOUNTED
ACTUATOR, PNEUMATIC
AFMA
AIR FLOW MEASUREMENT ARRAY,
WITH FLOW TRANSMITTER
SEE "DEVICE SYMBOL, GENERIC"
BOILER
CHILLER
COIL, COOLING
COIL, COOLING, DIRECT-EXPANSION
COIL, HEATING
COIL, ELECTRIC HEAT
COIL, PRECOOL
COIL, PREHEAT
CLOSED WHEN PRESSURE IS BELOW SETPOINT
OPEN WHEN PRESSURE IS ABOVE SETPOINT
SHOWN IN ACTIVATED POSITION
CLOSED WHEN PRESSURE IS BELOW SETPOINT
OPEN WHEN PRESSURE IS ABOVE SETPOINT
SHOWN IN UNACTIVATED POSITION
OPEN WHEN PRESSURE IS BELOW SETPOINT
SHOWN IN ACTIVATED POSITION
CLOSED WHEN PRESSURE IS ABOVE SETPOINT
Rxx-YY
Rxx-YY
Rxx
MS-#
MOTOR
MOTOR STARTER
(SOLENOID) NUMBER
xx = SEQUENTIAL RELAY
NORMALLY OPEN
xx = RELAY COIL NUMBER
YY = CONTACT NUMBER
NORMALLY CLOSED
xx = RELAY COIL NUMBER
YY = CONTACT NUMBER
HEAT EXCHANGER
AIR
MAIN
MAIN AIR
D-##
## = DAMPER NUMBER AS SHOWN
NORMALLY OPEN OR CLOSED AS SHOWN
DAMPER, OPPOSED BLADE
## = DAMPER NUMBER AS SHOWN
NORMALLY OPEN OR CLOSED AS SHOWN
DAMPER, PARALLEL BLADE
D-##
V-##
VALVE, NORMALLY OPEN
WITH SPRING RETURN FAILSAFE
WITH SPRING RETURN FAILSAFE
VALVE, NORMALLY CLOSED
V-##
VALVE, BALANCING
STAT
SEE "DEVICE SYMBOL, GENERIC"
TEMPERATURE SENSOR, AVERAGING
TEMPERATURE GAGE
SWITCH, MANUAL
SEE "DEVICE SYMBOL, GENERIC"
SMOKE DETECTOR, DUCT-MOUNTED
RESET BUTTON FOR SAFETY RESETRST-BUT
RADIATOR
PUMP
SEE "DEVICE SYMBOL, GENERIC"
L = LOW PRESSURE TAP
H = HIGH PRESSURE TAP
PRESSURE GAGE
POSITIVE POSITIONER
## = SEQUENTIAL NUMBER
LOCAL DISPLAY PANEL
LDP
FILTER
FAN
## = SEQUENTIAL NUMBER
ELECTRIC-TO-PNEUMATIC TRANSDUCER
EPS
(SOLENOID ACTUATED PNEUMATIC VALVE)
## = SEQUENTIAL NUMBER
ELECTRIC-TO-PNEUMATIC SWITCH
COM
V-##
COM
V-##
WITH SPRING RETURN FAILSAFE
VALVE, 3-WAY MIXING
NC = NORMALLY CLOSED
WITH SPRING RETURN FAILSAFE
VALVE, 3-WAY DIVERTING
NC = NORMALLY CLOSED
VARIABLE FREQUENCY DRIVE
SS = START/STOP COMMAND
S = STATUS FEEDBACK (ON/OFF)
XX-S
VFD
XX-SSXX-C
SEE "DEVICE SYMBOL, GENERIC"
WITH GAGE
PRESSURE SWITCH, DIFFERENTIAL,
CONTROLLED
XX = PROCESS/DEVICE BEING
CONTROL SIGNAL
C = 4-20 mA, VDC, or SNVT
IN
IN
IN
B
A
A
B
IN
IN
IN
IN
IN
IN
DB
PID
IN
IN
T=___ SEC
IN
IN
NC
NO
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
IN
C D
UP
U
SCHEDULER
OUT
INPUTS
AND CLEAR
DOWN, RATE,
RAMP WITH UP, CLEAR
RATE
DOWNINCREASES)
DECREASES AS INPUT
RESET SCHEDULE (OUTPUT
RESET
RESET
OUT
INPUT INCREASES)
(OUTPUT INCREASES AS
RESET SCHEDULE
OUT
FUNCTION
SUBTRACTION
OUT
MINUS
SETPOINT
OUTPUT
DEFAULT
VALUE
ENABLE
OUT
ENABLED
WHEN NOT
DEFAULT OUTPUT
ENABLE AND
PID LOOP WITH
OUT
SWITCH
OUT
CONTROL
COM
OUT
UNOCC
OCC
HAND
OFF
OUT H-O-A SWITCH
R=RESET
S=SET
BINARY LATCH
R
LAT
S B OUT
OUTPUT IS TRUE
WHEN IN1>IN2
DEADBAND (DB).
COMPARATOR WITH
DB=___
COMP
OUT
IN2
IN1
OUT
LOGICAL AND FUNCTION
OUT
LOGICAL OR FUNCTION
LOGICAL NOT FUNCTION
Out
ANALOG HARDWARE INPUT
INPUT
BINARY HARDWARE
BINARY HARDWARE OUTPUT
ANALOG HARDWARE OUTPUT
SIGNAL INPUT
ANALOG OR BINARY
SIGNAL OUTPUT
ANALOG OR BINARY
CONSTANT VALUE
STATEMENT
CONDITIONAL IF___
DEFINED
FUNCTION AS
GENERIC MATH
OUT
MATH
PLUS
OUT
FUNCTION
ADDITION
SELECTOR
SIGNAL
MAXIMUM
OUT
MAX
SELECTOR
SIGNAL
MINIMUM
OUT
MIN
CONTROL LOGIC DIAGRAM SYMBOLS
LIMIT / FREEZESTAT
or TEMPERATURE LOW
I/O FUNCTIONS
THERMOSTAT WITH SPECIFIED
TIME DELAY
OUT=IN AFTER
ON DELAY TIMER
G
S T
E N
S T
E
J
L L
A R
D I
L E
G E
N D
S Y
M B
O
S
D
MI1
F
M C
R E
P A
B
I
L D I
N G
J
L
C
E D
C8107.27
| 2017-04-24T12:39:02-0500 | |
| BALES.JIMMIE.D.JR.1231309302 |
File details come from the government source that posted it. Updated .