RFI-0028 REV01-HANGAR DOOR OPENING CLARIFICATIONS AND DETAILS.pdf

PDF 1 MB Posted

Attached to
F-35 CONSTRUCT COMBINED WEAPONS FACILITY
Solicitation number
W50S6Y-25-B-A004
Issued by

About this file

These architectural design drawings detail the Aircraft Clearance Requirement Plan and Aircraft Clearance Sections for a Combined Weapons Facility (CWF) Hangar, specifically designed to accommodate F-35 aircraft. The detailed technical drawings provide precise dimensional specifications for aircraft positioning, including minimum clearance requirements of 10' in multiple directions, with total hangar dimensions measuring approximately 90' wide by 70' long. Key structural elements include a hangar roof height of 41', a universal fighter box clearance of 63' 9", and specialized design features to ensure proper aircraft placement and movement within the facility.

The drawings include multiple technical cross-sections showing wall construction details, featuring components such as steel columns, CMU block walls, insulation layers, metal studs, gypboard, air barriers, and expansion joints. The technical specifications demonstrate a comprehensive approach to creating a precise, functional space for aircraft maintenance and operations, with meticulous attention to structural integrity, thermal performance, and spatial requirements consistent with F-35 aircraft maintenance needs.

View the file

Other files

File Type Posted
Bid Submission Day Sign-In Sheet-3APR25.pdf PDF
LSGA239001_CWF IFB Abstract 1419-KO.pdf PDF
Q-A set 05G_W50S6Y25BA004 3.28.25 Final.pdf PDF
RFI-0086 Set 5 Q-3 Louvers locations_Parsons response.pdf PDF
Solicitation Amendment W50S6Y25BA0040002 SF 30 CWF.pdf PDF
Q-A set 04Gp2_W50S6Y25BA004.pdf PDF
CWF Spec 08 34 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Q-A set 04G_W50S6Y25BA004 3.18.25.pdf PDF
RFI-0057 Q-A-29 set 04_Parsons response.pdf PDF
CWF Spec 08 36 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Solicitation Amendment W50S6Y25BA0040001 SF 30 CWF.pdf PDF
Q-A set 03G_W50S6Y25BA004 3.11.25.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.8.pdf PDF
CWF Spec Section 08 34 16 VERTICAL LIFT FABRIC HANGAR DOOR.pdf PDF
CWF - RFI 0007 ATTACHMENT CU101.pdf PDF
Missing Page from 25BA004 Sign In Sheet.pdf PDF
Q-A set 02G_W50S6Y25BA004 3.7.25.pdf PDF
CWF - RFI 0007.pdf PDF
CWF - RFI 0009.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.9.pdf PDF
25BA004 Pre-Bid Site Visit PP.pptx PPTX presentation
GeoTech Rpt-Terracon.pdf PDF
CWF Pre-Proposal minutes.pdf PDF
Asbestos -Lead Paint Survey-Terracon.pdf PDF
CWF Sign In Sheet.pdf PDF
Q-A set 01G_W50S6Y25BA004 2.28.25.pdf PDF
Attach-1_JAXF35CWF-100P SPECIFICATIONS.pdf PDF
Attach-7_BrandName (FAR 6)_Monaco-C-COR-KO_Redacted.pdf PDF
Attach-6_BrandName (FAR 6)_Advantor-B COR-KO_Redacted.pdf PDF
Attach-9_125FW Form 2 Access request (Aug 2023).pdf PDF
Solicitation - W50S6Y25BA004 Construct CWF.pdf PDF
Attach-3_JAXF35CWF-100P GENERAL FP ELECT TELE DRAWINGS VOLUME 2 OF 3.pdf PDF
Attach-8_BrandName (FAR 6)_MMetasys-D-COR-KO_Redacted.pdf PDF
Attach-2_JAXF35CWF-100P GENERAL CS ARCH DRAWINGS VOLUME 1 OF 3.pdf PDF
Attach-5_BrandName (FAR 6)_BestCores-A- COR-KO_Redacted.pdf PDF
Attach-4_JAXF35CWF-100P GENERAL MECH PLUM DRAWINGS VOLUME 3 OF 3.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DCBA.1

7.5

5.1

2.2

6.3

CWF HANGAR

H6

A-012

A6

A-012

A

7.4

1.9

D.1 E

/2

/2

70' - 7 1/2"

2' - 1" 17' - 2" 33' - 1" 16' - 11"

1' - 7 1/2"

3 3/4"

MIN. CLEAR

10' - 0"

1' - 11 1/2"

L9

A-022

B9

A-022

M

IN

C

L E

A R

MIN. CLEAR

10' - 0"

M

IN

C

L E

A R

/4

1' - 5 1/2"

B.2 B.8

F-15C 18'-5.5" 42'-9.75" 63'-9"

16'-8" 44'-6" 62'-1"

DENOTES AIRCRAFT DIMENSION TO

BE USED FOR CLEARANCES

AIRCRAFT SIZE CHART

AIRCRAFT HEIGHT WIDTH LENGTH

18'-5.5"

F-22

44'-6" 63'-9"

F-35A 14'-0" 35'-0" 51'-0"

UFC 4-211-01 10'-0" 2 X 10'-0"

MIN. DESIGN

CLEARANCES

28'-6" 64'-6" 83'-9"

2 X 10'-0"

UNIVERSAL FIGHTER BOX

B C

A

PLAN

NORTH

4' 8' 16'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x3

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

K S

O N

V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

A-011

CWF

A

IR

C R

A F

T C

L E

A R

A N

C E

R E

Q U

IR

E

M E

N T

P L A

N

JA

C

K S

O N

V

IL

L E

F

L O

R

ID

A J.

G A

R Z

A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

JA

N

U A

R Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

JA

X

-A N

G -W

L T

-A .R

V T

B-3 100% DESIGN SUBMITTAL

SCALE: 1/8" = 1'-0"

A6

AIRCRAFT CLEARANCE REQUIREMENT PLAN

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

A

STANLEY GEORGE

p0009678 Cloud

FINISH FLOOR

0' - 0"

T.O. PRE-CAST CAP

10' - 0"

762.8 7.55.132.22 6.3

SILL HT. HANGAR

36' - 0"

HANGAR ROOF

41' - 0"

C L

E A

R

CLEAR

10' - 0"

7.41.9 4 5

HANGAR ROOF HP

47' - 6"

UNIVERSAL FIGHTER BOX

63' - 9"

CLEAR

10' - 0"

6.9

H A

N G

A R

D O

O R

C L

E A

R O

P E

N

IN

G

/4

U N

IV

E

R S

A L

F

IG

H T

E R

B O

X

/2

5.4

FINISH FLOOR

0' - 0"

T.O. PRE-CAST CAP

10' - 0"

D C B A.1

SILL HT. HANGAR

36' - 0"

HANGAR ROOF

41' - 0"

C L

E A

R

SILL HT. STORAGE BAY

GLAZING

15' - 0"

AD.1E

HANGAR ROOF HP

47' - 6"

UNIVERSAL FIGHTER BOX

44' - 6"

CLEAR

10' - 0"

U N

IV

E

R S

A L

F

IG

H T

E R

B O

X

/2

HANGAR WALL

TRANSITION

41' - 4 1/8"

CLEAR

10' - 0"

B.2B.8

F-15C 18'-5.5" 42'-9.75" 63'-9"

16'-8" 44'-6" 62'-1"

DENOTES AIRCRAFT DIMENSION TO

BE USED FOR CLEARANCES

AIRCRAFT SIZE CHART

AIRCRAFT HEIGHT WIDTH LENGTH

18'-5.5"

F-22

44'-6" 63'-9"

F-35A 14'-0" 35'-0" 51'-0"

UFC 4-211-01 10'-0" 2 X 10'-0"

MIN. DESIGN

CLEARANCES

28'-6" 64'-6" 83'-9"

2 X 10'-0"

UNIVERSAL FIGHTER BOX

B C

A

PLAN

NORTH

4' 8' 16'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x3

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

K S

O N

V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

A-012

CWF

A

IR

C R

A F

T C

L E

A R

A N

C E

R E

Q U

IR

E

M E

N T

S E

C T

IO

N

S

JA

C

K S

O N

V

IL

L E

F

L O

R

ID

A J.

G A

R Z

A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

JA

N

U A

R Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

JA

X

-A N

G -W

L T

-A .R

V T

B-3 100% DESIGN SUBMITTAL

SCALE: 1/8" = 1'-0"

H6

AIRCRAFT CLEARANCE SECTION

SCALE: 1/8" = 1'-0"

A6

AIRCRAFT CLEARANCE SECTION

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

A

STANLEY GEORGE

p0009678 Line p0009678 Text Box 28'-6"

J

D

2.2

E

STEEL COLUMN,

SEE STRUCTURAL

FULLY GROUTED

8" CMU BLOCK

1" SHAFT LINER

BOARD

ACOUSTICAL BATT

INSULATION

6" COLD-FORMED

METAL STUD @ 16" OC

5/8" GYPBOARD

FULLY GROUTED

8" CMU BLOCK

3 5/8" INSULATED

METAL STUDS @ 16" OC

PRE-CAST

BANDING BELOW

SPLIT-FACE CMU

BLOCK VENEER

7/8" HAT

CHANNEL

AIR BARRIER

2" INSULATED

METAL PANEL

3" SILICONE SEALING STRIP

EXPANSION JOINT WITH

EXTERIOR METAL COVER

AIR BARRIER

SPLIT-FACE CMU BLOCK VENEER

AIR GAP

5/8" GLASS MAT

SHEATHING BOARD

7/8" HAT CHANNEL

2" INSULATED METAL PANEL

D

7.4

D.1

8" CMU BLOCK

FULLY GROUTED

ACOUSTICAL

BATT INSULATION

2 LAYERS 5/8" GYPBOARD

6" COLD-FORMED METAL

STUD @ 16" OC

1" SHAFT LINER BOARD

5/8" GYPBOARD

AIR BARRIER

1" RIGID INSULATION

SPLIT-FACE CMU

BLOCK VENEER

PRE-CAST

BANDING BELOW

7/8" HAT CHANNELS

AIR BARRIER

2" INSULATED

METAL PANEL

1-3/4" AIR GAP

STEEL COLUMN,

SEE STRUCTURAL

3" SILICONE SEALING

STRIP EXPANSION JOINT

3/4" STEEL

PLATE

HHS 6X2.5X1/4-TYP

EQUAL OPPOSITE

SIDE

PREFINISHED

METAL TRIM

1"

INSULATED

LIGHT GUAGE

FRAMING

HANGAR

DOOR

2" SILICONE SEALING STRIP

EXPANSION JOINT WITH

EXTERIOR METAL COVER

STEEL COLUMN,

SEE STRUCTURAL

F.2

5/8" GYPBOARD

ACOUSTICAL BATT

INSLUATION

6" COLD-FORMED

METAL STUD @ 16" OC

SPLIT-FACED CMU BLOCK VENEER

PRE-CAST BANDING BELOW

FIXED ALUMNIUM

WINDOW, REFER TO

WINDOW SCHEDULE

INSULATED METAL PANEL

METAL PANEL LINER

5/8" GLASS MAT

SHEATHING BOARD

7/8" SUBFRAMING

5/8" GLASS MAT

SHEATHING BOARD

J.1

6.1

J

STEEL COLUMN, SEE

STRUCTURAL

5/8" GYPBOARD

ACOUSTICAL BATT

INSULATION

HM DOOR, REFER TO

DOOR SCHEDULE

SPLIT-FACED CMU

BLOCK VENEER

PRE-CAST BANDING BELOW

8" CMU BLOCK

5/8" GLASS MAT

SHEATHING BOARD

AIR BARRIER

1" RIGID INSULATION

5/8" GYPBOARD ON

7/8" METAL FURRING

CORNER

REINFORCEMENT,

TYP.

D

6.3

D.1 E

STEEL BRACING, SEE

STRUCTURAL

DOOR, REFER TO

DOOR SCHEDULE

2 LAYERS 5/8" GYPBOARD

5/8 GYPBOARD

6" COLD-FORMED METAL

STUDS @ 16" OC

ACOUSTICAL

BATT INSLUATION

6" COLD-FORMED METAL

STUDS @ 16" OC

8" CMU BLOCK

STEEL COLUMN, SEE

STRUCTURAL

9" 7 3/4" 10 3/4"

ACOUSTICAL

BATT INSLUATION

3" SILICONE SEALING

STRIP EXPANSION JOINT

1" SHAFT LINER BOARD

G

PRE-CAST

BANDING BELOW

SMOOTH-FACE

CMU BLOCK

VENEER

1" RIGID INSULATION

AIR BARRIER

5/8" GLASS MAT

SHEATHING BOARD

6" COLD-FORMED METAL

STUD @ 16" OC

5/8" GYPBOARD

STEEL BRACING,

SEE STRUCTURAL

8" CMU BLOCK

5/8" GYPBOARD ON

7/8" METAL FURRING

1.1

H.1G.2

PRE-CAST

BANDING BELOW

SPLIT-FACE CMU

BLOCK VENEER

1" RIGID INSULATION

AIR BARRIER

ACOUSTICAL

BATT INSLUATION

6" COLD-FORMED

METAL STUD @ 16" OC

5/8" GYPBOARD ON

7/8" METAL FURRING

STEEL COLUMN,

SEE STRUCTURAL

12" CMU BLOCK

5/8" GYPBOARD ON

3-5/8" METAL STUDS

CORNER

REINFORCEMENT, TYP.

H

STEEL COLUMN AND BRACING,

SEE STRUCTURAL

PRE-CAST BANDING (BELOW)

SMOOTH-FACE CMU

BLOCK VENEER

1" RIGID INSULATION

AIR BARRIER

5/8" GLASS MAT SHEATHING BOARD

6" COLD-FORMED METAL

STUDS @ 16" OC

5/8" GYPBOARD

FIXED ALUMINUM WINDOW -

REFER TO WINDOW

SCHEDULE

ACOUSTICAL BATT INSULATION

4"0' 8" 1'-4"

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

A-501

CWF

P L A

N D

E T

A

IL

S

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A J G

A R

Z A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-A .R

V T

B-3 100% DESIGN SUBMITTAL

SCALE: 1 1/2" = 1'-0"

K2

PLAN DETAIL - GRID D/2.2

SCALE: 1 1/2" = 1'-0"

A2

PLAN DETAIL - GRID D/7.4

SCALE: 1 1/2" = 1'-0"

K9

PLAN DETAIL - GRID F.2/7.3

SCALE: 1 1/2" = 1'-0"

F9

PLAN DETAIL - GRID J.1/6

SCALE: 1 1/2" = 1'-0"

K14

PLAN DETAIL - GRID D/6.2

SCALE: 1 1/2" = 1'-0"

F14

PLAN DETAIL - GRID G/2

SCALE: 1 1/2" = 1'-0"

A9

PLAN DETAIL - GRID H.1/1.1

SCALE: 1 1/2" = 1'-0"

A14

PLAN DETAIL - GRID H/7

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

A

STANLEY GEORGE

p0009678 Line p0009678 Text Box

3/4" HALLO-BOLT FASTENER PER ICC ESR-3330 AT 18"

O/C-TYP

p0009678 Cloud p0009678 Arrow p0009678 Arrow p0009678 Arrow p0009678 Arrow p0009678 Arrow p0009678 Text Box 65'-5 1/2"

PER DOOR MFG

CONTRACTOR TO CONFIRM FINAL DESIGN W/ DOR

p0009678 PolyLine p0009678 Arrow p0009678 PolyLine p0009678 Line p0009678 Line p0009678 Text Box 4-12 p0009678 Line p0009678 Line p0009678 Arc p0009678 Arc p0009678 Text Box

TYP

STAGGERED

p0009678 Cloud p0009678 Cloud

File details come from the government source that posted it. Updated .