Attach-3_JAXF35CWF-100P GENERAL FP ELECT TELE DRAWINGS VOLUME 2 OF 3.pdf

PDF 31 MB Posted

Attached to
F-35 CONSTRUCT COMBINED WEAPONS FACILITY Federal contract opportunity
Solicitation number
W50S6Y-25-B-A004
Issued by
Department of the Army Florida Army National Guard

About this file

This file appears to be Volume 2 of 3 containing general electrical and telecommunications drawings for the F-35 Combined Weapons Facility construction project at Jacksonville International Airport. While the specific drawing details are not provided in the shared content, this would typically include technical drawings and specifications for the electrical and telecommunications systems to be installed in the 22,696 square-foot facility, which includes a Hangar Bay, weapons and release systems shops, administrative offices, classrooms, break room, and restrooms.

This document is referenced as part of solicitation W50S6Y-25-B-A004, a small business set-aside construction project with a magnitude of $10M-$25M being managed by the Florida Army National Guard. The drawings would serve as technical guidance for contractors bidding on the electrical and telecommunications portions of the construction project.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 CONSTRUCT COMBINED WEAPONS FACILITY, newest first.
File Type Posted
LSGA239001_CWF IFB Abstract 1419-KO.pdf PDF
Bid Submission Day Sign-In Sheet-3APR25.pdf PDF
Q-A set 05G_W50S6Y25BA004 3.28.25 Final.pdf PDF
RFI-0028 REV01-HANGAR DOOR OPENING CLARIFICATIONS AND DETAILS.pdf PDF
RFI-0086 Set 5 Q-3 Louvers locations_Parsons response.pdf PDF
Solicitation Amendment W50S6Y25BA0040002 SF 30 CWF.pdf PDF
Q-A set 04Gp2_W50S6Y25BA004.pdf PDF
CWF Spec 08 34 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Q-A set 04G_W50S6Y25BA004 3.18.25.pdf PDF
RFI-0057 Q-A-29 set 04_Parsons response.pdf PDF
Solicitation Amendment W50S6Y25BA0040001 SF 30 CWF.pdf PDF
CWF Spec 08 36 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Q-A set 03G_W50S6Y25BA004 3.11.25.pdf PDF
CWF - RFI 0007 ATTACHMENT CU101.pdf PDF
CWF Spec Section 08 34 16 VERTICAL LIFT FABRIC HANGAR DOOR.pdf PDF
Missing Page from 25BA004 Sign In Sheet.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.9.pdf PDF
Q-A set 02G_W50S6Y25BA004 3.7.25.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.8.pdf PDF
CWF - RFI 0007.pdf PDF
CWF - RFI 0009.pdf PDF
25BA004 Pre-Bid Site Visit PP.pptx PPTX presentation
Q-A set 01G_W50S6Y25BA004 2.28.25.pdf PDF
GeoTech Rpt-Terracon.pdf PDF
Asbestos -Lead Paint Survey-Terracon.pdf PDF
CWF Pre-Proposal minutes.pdf PDF
CWF Sign In Sheet.pdf PDF
Attach-1_JAXF35CWF-100P SPECIFICATIONS.pdf PDF
Attach-2_JAXF35CWF-100P GENERAL CS ARCH DRAWINGS VOLUME 1 OF 3.pdf PDF
Attach-4_JAXF35CWF-100P GENERAL MECH PLUM DRAWINGS VOLUME 3 OF 3.pdf PDF
Attach-5_BrandName (FAR 6)_BestCores-A- COR-KO_Redacted.pdf PDF
Solicitation - W50S6Y25BA004 Construct CWF.pdf PDF
Attach-6_BrandName (FAR 6)_Advantor-B COR-KO_Redacted.pdf PDF
Attach-7_BrandName (FAR 6)_Monaco-C-COR-KO_Redacted.pdf PDF
Attach-8_BrandName (FAR 6)_MMetasys-D-COR-KO_Redacted.pdf PDF
Attach-9_125FW Form 2 Access request (Aug 2023).pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

TASK ORDER NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

Florida Air

National Guard ®

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

CLIENT LOGO

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

G-001

CWF

C O

V E

R S

H E

E T

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A J G

A R

Z A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-A .R

V T

W50S6Y24F0001

FA8903-21-D-0011

JANUARY 2025

VOLUME 2 OF 3

JACKSONVILLE, FLORIDA

F-35 CONSOLIDATED WEAPONS FACILITY

B-3 100% DESIGN SUBMITTAL

W50S6Y24F0001

W S

Y

F

CWF LOCATIONPROJECT LOCATION

NN

PROJECT # LSGA239001

STANLEY GEORGE

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

G-003

CWF

IN

D

E X

O F

D R

A W

IN

G

S

V O

L U

M E o f

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A J G

A R

Z A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-A .R

V T

B-3 100% DESIGN SUBMITTAL

VOLUME 2 of 3

GENERAL

SHEET ID SHEET TITLE

G-001 COVER SHEET

G-002 INDEX OF DRAWINGS (VOLUME 1 of 3)

G-003 INDEX OF DRAWINGS (VOLUME 2 of 3)

G-004 INDEX OF DRAWINGS (VOLUME 3 of 3)

FIRE PROTECTION

SHEET NO. SHEET TITLE

FL001 CODE ANALYSIS

FL101 CODE COMPLIANCE SITE PLAN

FL102 LIFE SAFETY FLOOR PLAN

FL103 LIFE SAFETY EGRESS FLOOR PLAN - OVERALL

FL104 LIFE SAFETY EGRESS FLOOR PLAN - AREA A

FL105 LIFE SAFETY EGRESS FLOOR PLAN - AREA B

FL106 LIFE SAFETY EGRESS FLOOR PLAN - AREA C

FX001 FIRE SUPPRESSION GENERAL NOTES

FX101 FIRE SUPPRESSION HAZARD CLASSIFICATION FLOOR PLAN

FX401 FIRE SUPPRESSION ENLARGED PLANS

FA001 FIRE ALARM GENERAL NOTES

FA101 FIRE ALARM FLOOR PLAN - OVERALL

FA102 FIRE ALARM FLOOR PLAN - AREA A

FA103 FIRE ALARM FLOOR PLAN - AREA B

FA104 FIRE ALARM FLOOR PLAN - AREA C

FA501 FIRE ALARM DETAILS

FA502 FIRE ALARM MATRIX

FA601 FIRE ALARM RISER DIAGRAM

ELECTRICAL

SHEET NO. SHEET TITLE

E-001 ELECTRICAL SYMBOL LEGENDS

E-002 GENERAL ELECTRICAL ABBREVIATIONS AND NOTES

EG101 GROUNDING PLAN - OVERALL

EG102 GROUNDING PLAN - AREA A

EG103 GROUNDING PLAN - AREA B

EG104 GROUNDING PLAN - AREA C

EG105 LIGHTNING PROTECTION PLAN

EG106 LIGHTNING PROTECTION PLAN - AREA A

EG107 LIGHTNING PROTECTION PLAN - AREA B

EG108 LIGHTNING PROTECTION PLAN - AREA C

EG501 GROUNDING DETAILS

EG502 GROUNDING DETAILS

EG503 GROUNDING DETAILS

EG504 GROUNDING RISER DIAGRAM

EG511 LIGHTNING PROTECTION DETAILS

EL101 LIGHTING PLAN - OVERALL

EL102 LIGHTING PLAN - AREA A

EL103 LIGHTING PLAN - AREA B

EL104 LIGHTING PLAN - AREA C

EL105 ROOF LIGHTING PLAN

EL501 LIGHTING DETAILS

EL502 LIGHTING DETAILS

EL503 LIGHTING DETAILS

EL504 LIGHTING DETAILS

EL505 LIGHTING DETAILS

EL601 LIGHTING FIXTURE SCHEDULE

EL602 LIGHTING CONTROLS SCHEDULE

EP101 POWER PLAN - OVERALL

EP102 POWER PLAN - AREA A

EP103 POWER PLAN - AREA B

EP104 POWER PLAN - AREA C

EP105 MECH POWER PLAN - OVERALL

EP106 MECH POWER PLAN - AREA A

EP107 MECH POWER PLAN - AREA B

EP108 MECH POWER PLAN - AREA C

EP109 HAZARD CLASSIFICATION PLAN

EP110 HAZARD CLASSIFICATION PLAN - AREA A

EP111 HAZARD CLASSIFICATION PLAN - AREA B

EP301 HAZARD CLASSIFICATION SECTION

EP302 ELEVATION PLANS

EP401 ENLARGED POWER PLANS

EP501 POWER DETAILS

EP502 POWER DETAILS

EP601 PANELBOARD SCHEDULES

EP602 PANELBOARD SCHEDULES

EP603 PANELBOARD SCHEDULES

EP604 ELECTRICAL EQUIPMENT SCHEDULE

EP610 FEEDER SCHEDULE

EP701 SINGLE LINE DIAGRAM

TELECOM

SHEET NO. SHEET TITLE

T-001 GENERAL TELECOM SYMBOLS, ABBREVIATIONS AND NOTES

T-111 TELECOM PLAN - OVERALL

T-112 TELECOM PLAN - AREA A

T-113 TELECOM PLAN - AREA B

T-114 TELECOM PLAN - AREA C

T-401 TELECOM ENLARGED PLANS

T-501 TELECOM DETAILS

T-502 CABLE TRAY DETAILS

T-503 WIRING DETAILS

T-504 TELECOM DETAILS

T-505 TELECOM DETAILS

T-601 TELECOM RISER DIAGRAM

TY001 IDS AND ESS SYSTEM NOTES

TY101 SECURITY PLAN - OVERALL

TY102 SECURITY PLAN - AREA A

TY103 SECURITY PLAN - AREA B

TY104 SECURITY PLAN - AREA C

TY501 SECURITY DOOR DETAILS

TY502 SECURITY DETAILS

TY503 SECURITY RISER DIAGRAM AND SCHEDULE

STANLEY GEORGE

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL001

CWF

C O

D E

A N

A L Y

S

IS

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

1. 2021 INTERNATIONAL BUILDING CODE (IBC), AS REFERENCED AND AMENDED BY UFC 1-200-01, CHANGE 2

2. NFPA 1, FIRE CODE, 2024

3. NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2022

4. NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022

5. NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 2021

6. NFPA 70, NATIONAL ELECTRICAL CODE (NEC), 2023

7. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022

8. NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2022

9. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2021

10. NFPA 101, LIFE SAFETY CODE, 2024

11. NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION, 2021

12. NFPA 400, HAZARDOUS MATERIALS CODE, 2022

13. NFPA 409, STANDARD ON AIRCRAFT HANGARS, 2022

14. UFC 1-200-01, DoD BUILDING CODE (GENERAL BUILDING REQUIREMENTS), CHANGE 2, JUNE 12, 2023

15. UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, CHANGE 2, APRIL 12, 2021

16. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021

17. UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, CHANGE 2, JULY 30, 2022

18. UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE 1, JANUARY 1, 2010

19. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY DAF FOAM SUNDOWN POLICY

20. ENGINEERING AND CONSTRUCTION BULLETIN, NO. 2018-17, NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS

NOTIFICATION SYSTEMS, OCTOBER 25, 2018

21. ANGETL 10-03 AIR NATIONAL GUARD DESIGN OBJECTIVES AND PROCEDURES, APRIL 16, 2010

22. ANGETL 15-01, AIR NATIONAL GUARD DESIGN POLICY, MAY 1, 2015

23. ANGETL 15-01-03, FIRE PROTECTION DESIGN GUIDANCE, MAY 1, 2015

24. F-35 LIGHTNING II FACILITIES REQUIREMENTS DOCUMENTS, SEPTEMBER 2023

THE BUILDING IS A NON-SEPARATED MIXED-USE BUILDING PER IBC 508.3 WITH THE FOLLOWING OCCUPANCIES:

A-3, ASSEMBLY PER IBC SECTION 303.4 AND ASSEMBLY PER NFPA 101 SECTION 6.1.2.1

B, BUSINESS PER IBC SECTION 304.1 AND BUSINESS PER NFPA 101 SECTION 6.1.11.1

F-1, MODERATE HAZARD INDUSTRIAL PER IBC SECTION 306.2 AND INDUSTRIAL PER NFPA 101 SECTION 6.1.12.1 S-1, MODERATE HAZARD STORAGE PER IBC SECTION 311.2 AND STORAGE PER NFPA 101 SECTION 6.1.13.1

SEE OCCUPANT LOAD IN UFC 3-600-01, TABLE 10-4 AND NFPA 101, TABLE 7.3.1.2 AND OCCUPANT LOAD TABLE ON THIS SHEET.

THE FACILITY WILL NOT EXCEED THE ALLOWABLE AREA OR HEIGHT FOR TYPE IIB CONSTRUCTION FOR A SINGLE STORY

ABOVE GRADE BUILDING EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM.

TYPE IIB (NON FIRE-RESISTANT RATED, NONCOMBUSTIBLE CONSTRUCTION) (IBC SECTION 602.2)

OCCUPANT LOAD FACTORS PER NFPA 101 TABLE 7.3.1.2 AND UFC 3-600-01 TABLE 10-1.

MINIMUM INTERIOR AND CEILING FINISH AND FLOOR FINISH REQUIREMENTS PER NFPA 101 TABLE A.10.2.2

OCCUPANT LOAD

CODE OF RECORD

BUILDING OCCUPANCY CLASSIFICATION

ALLOWABLE AREA AND HEIGHT

CONSTRUCTION TYPE

PASSIVE FIRE PROTECTION

OPENING PROTECTION

INTERIOR FINISH

FIRE EXTINGUISHERS

FIRE SUPPRESSION

FIRE ALARM

TOTAL 20703 233

WEAPONS LOAD STORAGE BAY 132 STORAGE 4988 500 GROSS 10

WEAPONS RELEASE SHOP 131 INDUSTRIAL 1182 100 GROSS 12

GUN SERVICING/CLEANING 130 STORAGE 581 500 GROSS 2

TOOL CRIB 129 STORAGE 347 500 GROSS 1

SECURITY STOR 128 STORAGE 82 500 GROSS 1

MECH 2 127 STORAGE 175 500 GROSS 1

NCOIC SUPR 126 BUSINESS 126 150 GROSS 1

WEAPONS ELEMENT SUPR 125 BUSINESS 125 150 GROSS 1

CORRIDOR 4 124B BUSINESS 436 150 GROSS 3

CORRIDOR 3 124A BUSINESS 117 150 GROSS 1

CORRIDOR 2 124 BUSINESS 274 150 GROSS 2

WEAPONS LOAD SHOP OFFICE 123 BUSINESS 1493 50 GROSS 30

TEST & TRAINING 122 BUSINESS 486 15 NET 33

BREAK ROOM 120 BUSINESS 222 15 NET 15

OFFICE 119 BUSINESS 125 150 GROSS 1

WING WEAPONS MANAGER 118 BUSINESS 130 150 GROSS 1

COMM 117 STORAGE 127 500 GROSS 1

ELEC 116 STORAGE 134 500 GROSS 1

FIRE PROTECT 115 STORAGE 114 500 GROSS 1

MECH 1 114 STORAGE 508 500 GROSS 2

PPE STORAGE 113 STORAGE 104 500 GROSS 1

JAN CLOSET 112 STORAGE 35 500 GROSS 1

STORAGE 111 STORAGE 60 300 GROSS 1

MEN 110 LOCKERS 425 50 GROSS 9

WOMEN 109 LOCKERS 219 50 GROSS 5

CLASSROOM 108 ASSEMBLY 1012 15 NET 68

CORRIDOR 1 107 BUSINESS 381 150 GROSS 3

LOBBY 106 BUSINESS 104 15 NET 7

VEST 1 105 BUSINESS 132 150 GROSS 1

OFFICE 104 BUSINESS 123 150 GROSS 1

SHARED OFFICE 103 BUSINESS 242 150 GROSS 2

VEST 2 102 BUSINESS 51 150 GROSS 1

CWF HANGAR 101 STORAGE 6043 500 GROSS 13

ROOM NAME

ROOM

NUMBER

FUNCTION/USE

AREA (NET

SQ. FT.)

OCCUPANT LOAD

FACTOR (SF/PER.)

CALCULATED

OCCUPANT LOAD

CLASS A - FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450

CLASS B - FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450

CLASS C - FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450

CLASS I - CRITICAL RADIANT FLUX, NOT LESS THAN 0.45 W/SQ.CM.

CLASS II - CRITICAL RADIANT FLUX, NOT LESS THAN 0.22 W/SQ.CM. BUT LESS THAN 0.45 W/SQ.CM.

TOTAL 20,708

S-1 70,000 17,500 17,500 x .75 = 13,125 83,125 13,302

F-1 62,000 15,500 15,500 x .75 = 11,625 73,625 1,182

B 92,000 23,000 23,000 x .75 = 17,250 109,250 5,210

A-3 38,000 9,500 9,500 x .75 = 7,125 45,125 1,014

SINGLE STORY

WITH SPRINKLER

NON-

SPRINKLER

OCCUPANCY AREA (SQ. FT.) (IBC TABLE 506.2)

FRONTAGE INCREASE (SQ.

FT.) (IBC SECTION 506.3)

ALLOWABLE AREA (SQ. FT.)

(IBC SECTIONS 506.2.2 AND

508.4.2)

ACTUAL AREA

NET (SQ. FT.)

ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 0

FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 0

FIRE SEPARATION DISTANCE OF 30 FEET OR MORE 0 0

FIRE SEPARATION DISTANCE OF AT LESAT 10 FEET BUT LESS THAN 30 FEET 0 0

FIRE SEPARATION DISTANCE OF AT LEAST 5 FEET BUT LESS THAN 10 FEET 1 1

FIRE SEPARATION DISTANCE LESS THAN 5 FEET 1 2

NONBEARING EXTERIOR WALLS:

BEARING WALLS - INTERIOR AND EXTERIOR 0 0

PRIMARY STRUCTURAL FRAME 0 0

TYPE IIB - BUILDING ELEMENT

FIRE-RESISTANCE

RATING GROUP A-3, B

(HOURS)

FIRE-RESISTANCE

RATING GROUP

F-1, S-1 (HOURS)

MECHANICAL ROOM (127) SMOKE PARTITION NFPA 101 SECTION 38.3.2.1 AND SECTION 8.7.1.2

MECHANICAL ROOM (114) SMOKE PARTITION NFPA 101 SECTION 38.3.2.1 AND SECTION 8.7.1.2

CWF HANGAR (101) 1 HR FIRE BARRIER UFC 4-211-01 SECTION 3-3.1.3

FIRE PROTECTION ROOM (115) 1 HR FIRE BARRIER UFC 4-211-01 SECTION 3-6.7

ROOM RATING (HOUR) CODE SECTION

SMOKE

PARTITION

N/A N/A N/A

CLASS II FOR AIR TRANSFER

OPENINGS ONLY

FIRE

BARRIER

1 HR 0.75 HR

1.5 HR FOR AIR

TRANSFER OPENINGS

ONLY

N/A

TYPE OF

ASSEMBLY

REQUIRED

ASSEMBLY

RATING (HOURS)

MINIMUM FIRE DOOR AND FIRE

SHUTTER ASSEMBLY RATINGS

(HOURS) (NFPA 101 TABLE 8.3.3.2.2)

MINIMUM FIRE DAMPER

RATINGS (HOURS) (NFPA

90A SECTION 9.2.1.1)

MINIMUM SMOKE DAMPER

RATING (HOURS) (NFPA 101

SECTIONS 8.4.6.2 AND 8.4.6.3)

MEANS OF EGRESS

EXITS AND EXIT CAPACITY:

THE EXITS ARE REQUIRED TO BE SEPARATED FROM EACH OTHER BY AT LEAST ONE-THIRD THE DIAGONAL OF THE FLOOR

AREA IN WHICH THEY SERVE (NFPA 101 SECTION 7.5.1.3.3).

CWF HANGAR AREA:

OVERALL DIAGONAL: 111'-7"

REMOTENESS OF EXITS: 92'-0"

OFFICE AREA:

OVERALL DIAGONAL: 120'-9"

REMOTENESS OF EXITS: 92'-3"

WEAPONS LOAD STORAGE BAY AREA:

OVERALL DIAGONAL: 107'-6"

REMOTENESS OF EXITS: 99'-4"

COMMON PATH, DEAD-END AND TRAVEL DISTANCE (BY OCCUPANCY) NFPA 101 TABLE A.7.6

FLOOR

CLASS I

OR II

CLASS I OR II N/A

CLASS I

OR II

CLASS I OR II N/A

CLASS I OR

II

CLASS I OR II N/A

WALL/

CEILING

A A OR B A, B, OR C A OR B A OR B A, B, OR C A OR B A, B, OR C A, B, OR C

EXITS

EXIT ACCESS

CORRIDORS

OTHER

SPACES

EXITS

EXIT ACCESS

CORRIDORS

OTHER

SPACES

EXITS

EXIT ACCESS

CORRIDORS

OTHER

SPACES

ASSEMBLY OCC. BUSINESS OCC. INDUSTRIAL AND STORAGE OCC.

TYPE

SPRINKLERED

THE FACILITY WILL BE PROTECTED BY GENERAL PURPOSE DRY CHEMICAL ABC FIRE EXTINGUISHERS IN ACCORDANCE

WITH NFPA 10 CHAPTER 6 AS REQUIRED BY UFC 3-600-01 SECTION 9-17.2.1.

MINIMUM REQUIREMENTS FOR LIGHT AND ORDINARY HAZARD CLASSIFICATIONS ARE AS FOLLOWS:

LIGHT HAZARD = 2A:10B:C COVERING 6,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 75 FEET.

ORDINARY HAZARD = 2A:10:B:C COVERING 3,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 75 FEET.

EXTRA HAZARD = 4A:80B:C COVERING 4,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 50 FEET.

PORTABLE FIRE EXTINGUISHERS WILL BE PROVIDED IN ACCORDANCE WITH NFPA 101 SECTION 9.9.

A WET PIPE SPRINKLER SYSTEM SHALL BE INSTALLED THROUGHOUT THE BUILDING IN ACCORDANCE WITH UFC 3-600-01, UFC 4-211-01 AND AIR FORCE MEMORANDUM FOAM SUNDOWN POLICY. THE BUILDING WILL HAVE AUTOMATIC FIRE SPRINKLER

COVERAGE AS SHOWN ON THE FIRE SUPPRESSION DRAWINGS.

THE SEISMIC DESIGN CATEGORY (SDC) FOR THE CWF BUILDING IS CLASS B.

COMBINATION FIRE ALARM/MASS NOTIFICATION (MNS) THROUGHOUT THE BUILDING – AS SHOWN ON FIRE ALARM DRAWINGS.

BUILDING FIRE ALARM MASS NOTIFICATION CONTROL PANEL (FACU/ACU) WILL BE CONNECTED TO THE BASE REPORTING SYSTEM. TRANSCEIVERS USED FOR CONNECTION TO THE BASE REPORTING SYSTEM SHALL BE COMPATIBLE WITH THE BASE MONACO TRANSCEIVER SYSTEM. IN-BUILDING MNS INTERFACE TO BE STAND ALONE. IN-BUILDING MNS TO BE EQUIPPED WITH

600-OHM AUDIO INPUT TO ALLOW FOR FUTURE WIDE-AREA MNS INTEGRATION.

ELECTRICAL HAZARD CLASSIFICATIONS

THE REQUIREMENTS OF UFC 4-211-01 SECTION 3-7.1 SHALL BE APPLIED. INSIDE THE HANGAR BAY, ALL ELEVATIONS UNDER FINISHED FLOOR SHALL HAVE AN ELECTRICAL CLASS 1, DIV. 1 RATING. THE AREA BETWEEN FINISHED FLOOR AND 18 INCHES ABOVE FINISHED FLOOR IN THE HANGAR BAY, ANY AREA WITHIN 5 FEET OF AIRCRAFT, AND ALL ADJOINING SPACES THAT ARE NOT SUITABLY CUT-OFF PER NFPA 70 SECTION 513.3 (B), SHALL HAVE AN ELECTRICAL HAZARD CLASS 1, DIV. 2 RATING. REFER TO

SHEETS EP109, EP110, EP111, AND EP301 FOR DRAWINGS SHOWING THESE AREAS.

2A:10B:C WEAPONS LOAD STORAGE BAY (132) 2 ORDINARY HAZARD 75 3,000

2A:10B:C WEAPONS RELEASE SHOP (131) 1 ORDINARY HAZARD 75 3,000

2A:10B:C GUN SERVICING/CLEANING (130) 1 ORDINARY HAZARD 75 3,000

2A:10B:C MECH 2 (127) 1 ORDINARY HAZARD 75 3,000

2A:10B:C CORRIDOR 4 (124B) 1 LIGHT HAZARD 75 6,000

2A:10B:C CORRIDOR 2 (124) 1 LIGHT HAZARD 75 6,000

2A:10B:C ELEC (116) 1 ORDINARY HAZARD 75 3,000

2A:10B:C MECH 1 (114) 1 ORDINARY HAZARD 75 3,000

2A:10B:C CORRIDOR 1 (107) 2 LIGHT HAZARD 75 6,000

4A:80B:C CWF HANGAR (101) 3 EXTRA HAZARD 50 4,000

FIRE

EXTINGUISHER

TYPE AND SIZE

ROOM NAME AND NUMBER

NUMBER OF

EXTINGUISHERS

HAZARD

CLASSIFICATION

MAXIMUM

TRAVEL

DISTANCE (FEET)

MAXIMUM AREA

OF COVERAGE

(SF)

STORAGE AND INDUSTRIAL 32 INCHES 34 INCHES 0.2

BUSINESS AND ASSEMBLY 32 INCHES 34 INCHES 0.2

OCCUPANCY REQUIRED CLEAR WIDTH ACTUAL MIN. CLEAR WIDTH FACTOR

STORAGE "S-1" 400 81 100 34 100 0

INDUSTRIAL "F-1" 250 61 100 61 50 0

BUSINESS "B" 300 97 100 41 50 18

ASSEMBLY "A-3" 250 74 20 0 20 0

OCCUPANCY

TYPE

(SPRINKLERED)

TRAVEL

DISTANCE (IN

FEET)

MESURED TRAVEL

DISTANCE (IN FEET)

COMMON

PATH (IN

FEET)

MEASURED

COMMON PATH

(IN FEET)

DEAD END (IN

FEET)

MEASURED DEAD

END (IN FEET)

CWF

SPRINKLER RISER

(FIRE PROTECT ROOM 115)

F

IR

E A

P P

A R

A T

U S

A C

C E

S S

R O

A D

F D

C

F .D

18' - 0"

OUTSIDE COVERED

STORAGE

EXISTING

BUILDINGS

MECHANICAL YARD

ENTRANCE

ENTRANCE

34' - 10"39' - 9"

F F F F F F F

F F

F F

F F

F

F F

F F F F F F

F

F

F

F F

F

DISTANCE TO

CANOPY

FSD

F S

D D

IS

T

A N

C E

T O

B

L D

G

R

R

R

F F

F F

F FF F H

O

S E

P U

L L

F F

F F

F

F

F

F

REFER TO CIVIL

DRAWINGS

REFER TO CIVIL

DRAWINGS

REFER TO CIVIL

DRAWINGS

R

F

F F

F

F

EXTERIOR

COVERED

STORAGE

F

R

F

F

F

F

F

REFER TO CIVIL

DRAWINGS

17' - 11"

FIRE SEPARATION DISTANCE

POST INDICATOR VALVE

FIRE DEPARTMENT ENTRANCE

FIRE DEPARTMENT CONNECTION

FIRE HYDRANT - TWO HOSE OUTLET AND ONE

PUMPER OUTLET

ISOLATION VALVE IN VAULT

FIRE DEPARTMENT ACCESS

FIRE DEPARTMENT ENTRANCE DISTANCE

IMAGINARY LOT LINE

HOSE PULL

DEDICATED UNDERGROUND FIRE WATER MAIN

FDC

F.D.

F

FSD

F F

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL101

CWF

C O

D E

C O

M P

L

IA

N C

E S

IT

E

P L A

N

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

A8

CODE COMPLIANCE SITE PLAN

1" = 30'-0"

SHEET NOTES

LEGEND

PLAN

NORTH

0 30' 60'

1. FIRE HYDRANTS SHALL BE SPACED NO GREATER

THAN 300-FEET APART PER UFC 4-211-01, SECTION

3-6.3.2

2. A MINIMUM OF ONE HYDRANT MUST BE LOCATED NO

GREATER THAN 150-FEET FROM THE FDC PER UFC

3-600-01, SECTION 9-3.5.8.4

3. ALL-WEATHER GROUND ACCESS EMERGENCY

VEHICLE ACCESS SHALL TERMINATE NO GREATER

THAN 33-FEET FROM THE EXTERIOR FIRE

DEPARTMENT ACCESS DOOR PER UFC 3-600-01,

SECTION 9-1.1

4. FIRE APPARATUS ACCESS ROADS SHALL HAVE NOT

LESS THAN 20-FEET UNOBSTRUCTED WIDTH EXCEPT

FOR SECURITY GATES THAT HAVE AN

UNOBSTRUCTED WIDTH OF 13-FEET, 6-INCHES PER

IFC, SECTION 503.2.1

5. RESPONDING FIRE DEPARTMENT HAS EQUIPMENT

APPARATUS MINIMUM TURNING RADIUS OF 39-FEET,

10-INCHES.

6. LOCATE AT LEAST ONE FIRE HYDRANT NO GREATER

THAN 100-FEET OF EACH CORNER OF THE BUILDING

PER UFC 4-211-01, SECTION 3-6.3.2.

7. THE TWO HYDRANTS TO THE SOUTH OF THE

BUILDING ARE EXISTING AND ARE NOT IN THE SCOPE

OF WORK. THEY WILL REMAIN IN SERVICE AND

UNCHANGED. THE FURTHEST CORNER FURTHEREST

FROM A HYDRANT IS 110-FEET AND IS ACCEPTABLE.

WEAPONS LOAD

STORAGE BAY

WEAPONS

RELEASE SHOP

WEAPONS LOAD

SHOP OFFICE

BREAK ROOM

WING WEAPONS

MANAGER

OFFICE

SHARED OFFICE

VEST 2

CLASSROOM

TEST & TRAINING

WEAPONS

ELEMENT SUPR

NCOIC SUPR

MECH 2

COMM

PPE STORAGE

MECH 1

MEN

CWF HANGAR

LOBBY

CORRIDOR 1

CORRIDOR 2

VEST 1

WOMEN

TOOL CRIB

A MKJHGFEDCB

2S S

S S

S S

SSSS

S

S S

S S

S S

S S

S S

S S

S S

O V E R A

LL

S E C

TI

O N D

IA

G

O N A L

7' -6

R E M

O

TE

N

ES

S O

F

EX

IT

S

'-4

R E

M O

T E

N E

S S

O F

E X

IT

S

'-3

N

7.5

5.1

3.1

6.2

2.1

EXTERIOR

COVERED

STORAGE

EXTERIOR

MECHANICAL

YARD

EXTERIOR

COVERED

STORAGE

GUN

SERVICING/CLEANING

OFFICE

SECURITY STOR

OVERALL SECTIO

N D

IAGONAL

120'-9

R E

M O

T E

N E

S S

O F E

X

IT

S

'-0

O V E R

A

LL S

E C

TIO

N D

IA

G

O N A L

111'-7"

JAN CLOSET

STORAGE

FIRE PROTECT

CORRIDOR 3

124A

CORRIDOR 4

124B

ASSEMBLY "A-3" (IBC, SECTION 303.4) /

ASSEMBLY (NFPA 101, SECTION 6.1.2.1)

BUSINESS "B" (IBC, SECTION 304.1) /

BUSINESS (NFPA 101, SECTION 6.1.11.1)

MODERATE HAZARD STORAGE "S-1" (IBC,

SECTION 311.2) / STORAGE (NFPA 101,

SECTION 6.1.13.1)

MODERATE HAZARD FACTORY INDUSTRIAL

GROUP "F-1" (IBC, SECTION 306.2) / (NFPA

101 SECTION 6.1.12.1)

SMOKE PARTITION

1 HR FIRE BARRIER

DRY CHEMICAL ABC EXTINGUISHER

S

B C

A

PLAN

NORTH

8' 16' 32'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W E

S T

W A

L N

U T

S T

R E

E T

(6

-2

P

A S

A D

E N

A C

A L

IF

O

R N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L

E A

IR

N

A T

IO

N

A L

G U

A R

D

FL102

CWF

L

IF

E S

A F

E T

Y F

L O

O R

P L A

N

J A

C K

S O

N V

IL

L

E

F L

O R

ID

A

C

P E

T E

R S

O N

A B

A B

A

IA

N

S G

E O

R G

E

R

M E

D E

IR

O

S

J A

N U

A R

Y

W

S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L

T -F

.R V

T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

SCALE: 1/16" = 1'-0"

A8

LIFE SAFETY FLOOR PLAN - OVERALL

1. FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT

EXCEEDING 40 LB SHALL BE INSTALLED SO THAT THE

TOP OF THE FIRE EXTINGUISHER IS NOT MORE THAN

5 FT. ABOVE FLOOR.

2. FIRE EXTINGUISHERS SHALL BE INSTALLED SO THAT

THE FIRE EXTINGUISHER'S OPERATING

INSTRUCTIONS FACE OUTWARD.

3. CABINETS HOUSING FIRE EXTINGUISHERS SHALL

NOT BE LOCKED.

4. FOR FIRE RESISTANCE-RATED WALLS, ONLY

SURFACE-MOUNTED CABINETS OR LISTED FIRE-

RATED CABINETS SHALL BE INSTALLED.

5. FIRE EXTINGUISHERS SHALL BE INSTALLED IN

LOCATIONS WHERE THEY ARE VISIBLE AND WILL

COORDINATE WITH THE INSTALLATION OF EXIT

SIGNS, EMERGENCY AND EXIT LIGHTING WITH

ELECTRICAL DRAWINGS.

6. PROVIDE 2 FT. RED COLOR STRIPING CLEARANCE

FROM EXTINGUISHERS.

SHEET NOTES

LEGEND

A MKJHGFEDCB

TD=79'-7"

TD=73'-11"

T D

TD=72'-3"

T D

TD=86'-10"

TD=94'-5"TD=96'-6"

C P

TD=73'-2"

48'-0"

N

7.5

5.1

3.1

6.2

2.1

EXTERIOR

COVERED

STORAGE

EXTERIOR

MECHANICAL

YARD

EXTERIOR

COVERED

STORAGE

WEAPONS LOAD

STORAGE BAY

WEAPONS

RELEASE SHOP

WEAPONS LOAD

SHOP OFFICE

BREAK ROOM

WING WEAPONS

MANAGER

OFFICE

SHARED OFFICE

VEST 2

CLASSROOM

TEST & TRAINING

WEAPONS

ELEMENT SUPR

NCOIC SUPR

MECH 2

COMM

PPE STORAGE

MECH 1

MEN

CWF HANGAR

LOBBY

CORRIDOR 1

CORRIDOR 2

VEST 1

WOMEN

TOOL CRIB

GUN

SERVICING/CLEANING

OFFICE

SECURITY STOR

DE=17'-8"

M A

T C

H L

IN

E

/A

F L

M A

T C

H L

IN

E

/A

F L

M A

T C

H L

IN

E

/A

F L

M A

T C

H L

IN

E

/A

F L

JAN CLOSET

STORAGE

FIRE PROTECT

CORRIDOR 3

124A

CORRIDOR 4

124B

ILLUMINATED SINGLE SIDED EXIT SIGN

ILLUMINATED DOUBLE SIDED EXIT SIGN

TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END

EXIT ID

CLEAR WIDTH DOOR/STAIR (INCHES)

EGRESS CAPACITY FACTOR DOOR/STAIR

AVAILABLE EXIT CAPACITY (PERSONS)

ASSIGNED EXIT CAPACITY

TD

CP

DE

X

XX XX

0.2 0.3

B C

A

PLAN

NORTH

8' 16' 32'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL103

CWF

L

IF

E S

A F

E T

Y E

G R

E S

S F

L O

O R

P L A

N

O V

E R

A L L

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

SCALE: 1/16" = 1'-0"

A8

LIFE SAFETY EGRESS FLOOR PLAN - OVERALL

1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE

LOCATED AT VERTICAL DISTANCE OF NOT MORE

THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE

EGRESS OPENING INTENDED FOR DESIGNATION BY

THAT MARKING.

2. EGRESS MARKING SHALL BE LOCATED AT A

HORIZONTAL DISTANCE OF NOT MORE THAN THE

REQUIRED WIDTH OF THE EGRESS OPENING, AS

MEASURED FROM THE EDGE OF THE EGRESS

OPENING INTENDED FOR DESIGNATION BY THAT

MARKING TO THE NEAREST EDGE OF THE MARKING.

ILLUMINATED SINGLE SIDED EXIT SIGN

ILLUMINATED DOUBLE SIDED EXIT SIGN

TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END

EXIT ID

CLEAR WIDTH DOOR/STAIR (INCHES)

EGRESS CAPACITY FACTOR DOOR/STAIR

AVAILABLE EXIT CAPACITY (PERSONS)

ASSIGNED EXIT CAPACITY

TD

CP

DE

X

XX XX

0.2 0.3

A EDCB

5.1

3.1

6.2

7.4

2.1

CWF HANGAR

B

34 NA

0.2 0.3

A

34 NA

0.2 0.3

C

34 NA

0.2 0.3

M A

T C

H L

IN

E

/A

F L

48'-0"

B C

A

PLAN

NORTH

4' 8' 16'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL104

CWF

L

IF

E S

A F

E T

Y E

G R

E S

S F

L O

O R

P L A

N

A R

E A

A

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE

LOCATED AT VERTICAL DISTANCE OF NOT MORE

THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE

EGRESS OPENING INTENDED FOR DESIGNATION BY

THAT MARKING.

2. EGRESS MARKING SHALL BE LOCATED AT A

HORIZONTAL DISTANCE OF NOT MORE THAN THE

REQUIRED WIDTH OF THE EGRESS OPENING, AS

MEASURED FROM THE EDGE OF THE EGRESS

OPENING INTENDED FOR DESIGNATION BY THAT

MARKING TO THE NEAREST EDGE OF THE MARKING.

SHEET NOTES

LEGEND

SCALE: 1/8" = 1'-0"

A8

LIFE SAFETY EGRESS FLOOR PLAN - AREA A

TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END

EXIT ID

CLEAR WIDTH DOOR/STAIR (INCHES)

EGRESS CAPACITY FACTOR DOOR/STAIR

AVAILABLE EXIT CAPACITY (PERSONS)

ASSIGNED EXIT CAPACITY

TD

CP

DE

X

XX XX

0.2 0.3

JHGFED

GUN

SERVICING/CLEANING

WEAPONS LOAD

SHOP OFFICE

BREAK ROOM

WING WEAPONS

MANAGER

OFFICE

SHARED OFFICE

CLASSROOM

TEST & TRAINING

WEAPONS

ELEMENT SUPR

NCOIC SUPR

MECH 2

COMM

PPE STORAGE

ELEC

JAN CLOSET

STORAGE

FIRE PROTECT

MECH 1

LOBBY

CORRIDOR 1

CORRIDOR 2

VEST 1

SECURITY STOR

WOMEN

TOOL CRIB

M A

T C

H L

IN

E

/A

F L

M A

T C

H L

IN

E

/A

F L

EXTERIOR

COVERED

STORAGE

EXTERIOR

MECHANICAL

YARD

OFFICE

MEN

D

68 NA

0.2 0.3

E

34 NA

0.2 0.3

F

34 NA

0.2 0.3

G

34 NA

0.2 0.3

H

34 NA

0.2 0.3

I

68 NA

0.2 0.3

J

34 NA

0.2 0.3

K

34 NA

0.2 0.3

P

68 NA

0.2 0.3

T D

T D

TD=86'-10"

TD=94'-5"TD=96'-6"

C P

TD=73'-2"

EXTERIOR

COVERED

STORAGE

EXTERIOR

MECHANICAL

YARD

DE=17'-8"

VEST 2

CORRIDOR 4

124B

CORRIDOR 3

124A

B C

A

PLAN

NORTH

4' 8' 16'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL105

CWF

L

IF

E S

A F

E T

Y E

G R

E S

S F

L O

O R

P L A

N

A R

E A

B

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE

LOCATED AT VERTICAL DISTANCE OF NOT MORE

THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE

EGRESS OPENING INTENDED FOR DESIGNATION BY

THAT MARKING.

2. EGRESS MARKING SHALL BE LOCATED AT A

HORIZONTAL DISTANCE OF NOT MORE THAN THE

REQUIRED WIDTH OF THE EGRESS OPENING, AS

MEASURED FROM THE EDGE OF THE EGRESS

OPENING INTENDED FOR DESIGNATION BY THAT

MARKING TO THE NEAREST EDGE OF THE MARKING.

SHEET NOTES

LEGEND

SCALE: 1/8" = 1'-0"

LIFE SAFETY EGRESS FLOOR PLAN - AREA B

TRAVEL DISTANCE

COMMON PATH OF TRAVEL

DEAD END

EXIT ID

CLEAR WIDTH DOOR/STAIR (INCHES)

EGRESS CAPACITY FACTOR DOOR/STAIR

AVAILABLE EXIT CAPACITY (PERSONS)

ASSIGNED EXIT CAPACITY

TD

CP

DE

X

XX XX

0.2 0.3

MKJ

N

WEAPONS LOAD

STORAGE BAY

WEAPONS

RELEASE SHOP

M A

T C

H L

IN

E

/A

F L

M

34 NA

0.2 0.3

L

34 NA

0.2 0.3

N

34 NA

0.2 0.3

TD=79'-7"

TD=73'-11"

T

D

TD=72'-3"

B C

A

PLAN

NORTH

4' 8' 16'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FL106

CWF

L

IF

E S

A F

E T

Y E

G R

E S

S F

L O

O R

P L A

N

A R

E A

C

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE

LOCATED AT VERTICAL DISTANCE OF NOT MORE

THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE

EGRESS OPENING INTENDED FOR DESIGNATION BY

THAT MARKING.

2. EGRESS MARKING SHALL BE LOCATED AT A

HORIZONTAL DISTANCE OF NOT MORE THAN THE

REQUIRED WIDTH OF THE EGRESS OPENING, AS

MEASURED FROM THE EDGE OF THE EGRESS

OPENING INTENDED FOR DESIGNATION BY THAT

MARKING TO THE NEAREST EDGE OF THE MARKING.

SHEET NOTES

LEGEND

SCALE: 1/8" = 1'-0"

LIFE SAFETY EGRESS FLOOR PLAN - AREA C

1. THE BUILDING WILL BE PROTECTED BY AUTOMATIC FIRE SPRINKLER SYSTEMS. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION MUST BE IN STRICT ACCORDANCE WITH THE MOST CURRENT EDITIONS OF NFPA 13, UFC 3-600-01, UFC

4-211-01 AND SPECIFICATION 21 13 13.

2. THE SPRINKLER SYSTEMS MUST BE HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA 13, UFC 3-600-01, UFC

4-211-01 AND SPECIFICATION 21 13 13.

3. SPRINKLER HEADS MUST BE BRASS UPRIGHTS WHERE NO FINISHED CEILING IS PROVIDED EXCEPT AS NOTED. WHERE A LAY IN CEILING IS PROVIDED, SPRINKLER HEADS MUST BE PENDENTS WITH A CHROME FINISH. THE USE OF EXTENDED COVERAGE SPRINKLERS IS PROHIBITED PER UFC 3-600-01 SECTION 9-7.4.3 EXCEPT AS NOTED. ALL SPRINKLERS ON THE GRID CEILING SHALL BE PLACED AT THE CENTER OF THE CEILING PANEL.

4. PROVIDE VALVE SUPERVISORY TAMPER DEVICES ON FIRE PROTECTION CONTROL VALVES FOR MONITORING BY THE

FIRE ALARM/MASS NOTIFICATION CONTROL PANEL.

5. SPRINKLER SYSTEM PIPING MUST BE BLACK STEEL PIPE WITH FURNACE BUTT-WELDS (ASTM A53, TYPE F). PIPING 2 IN.

AND LESS MUST BE MINIMUM SCHEDULE 40. PIPING LARGER THAN 2 IN. MUST BE MINIMUM SCHEDULE 10 IN.

ACCORDANCE WITH UFC 3-600-01 SECTION 9-7.6.2.

6. WET SPRINKLER PIPING IS PERMITTED TO BE INSTALLED LEVEL. AUXILIARY DRAINS MUST BE PROVIDED WHERE A CHANGE IN PIPING DIRECTION PREVENTS DRAINAGE OF SYSTEM PIPING THROUGH THE MAIN DRAIN OR THROUGH A SINGLE SPRINKLER HEAD WHERE LESS THAN 5 GALLONS OF WATER IS TRAPPED BY THE SINGLE SPRINKLER.

7. LOCATE THE SPRINKLER RISER INSPECTOR’S TEST CONNECTION AT THE RISER.

8. MARK EXPOSED INTERIOR PIPING WITH PLASTIC WRAP-AROUND TYPE PIPE LABELS CONFORMING TO AMERICAN SOCIETY OF MECHANICAL ENGINEERS/AMERICAN NATIONAL STANDARDS INSTITUTE (ASME/ANSI) A13.1. INDICATE THE TYPE OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS IN THE MECHANICAL ROOM MUST BE VISIBLE FROM AT LEAST THREE SIDES WHEN VIEWED FROM THE FLOOR. LABELS THAT STICK-ON (ADHESIVE BACKED) OR ARE HELD ON WITH STRAPS/ADHESIVE TAPE ARE NOT PERMITTED. LABELS ARE NOT REQUIRED ON FIRE SUPPRESSION SYSTEM BRANCH LINES REGARDLESS OF SIZE, OR MAINS AND CROSS-MAINS LESS THAN A NOMINAL 2-1/2 INCHES. LABELS ARE NOT REQUIRED ON PIPING ROUTED BELOW THE FLOOR LINE IN TRENCHES OR PITS. AT A MINIMUM, THE FOLLOWING LABELS ARE REQUIRED: "FIRE PROTECTION WATER" -USED ON DEDICATED POTABLE AND NON-PORTABLE FIRE PROTECTION WATER SUPPLY PIPING. "FIRE SPRINKLER" - USED ON WATER-ONLY SPRINKLER PIPING. "FIRE DEPT.

CONNECTION" - USED ON THE FDC PIPING.

9. FIRE SUPPRESSION SYSTEM VALVES MUST BE MARKED WITH PERMANENT TAGS INDICATING NORMALLY OPEN OR

NORMALLY CLOSED.

10. ROUTE CLEAR WATER DRAINS TO THE BUILDING EXTERIOR AND DISCHARGE NO GREATER THAN 2 FT. ABOVE GRADE.

PROVIDE INDEPENDENT ATMOSPHERIC AND PRESSURIZED DRAINAGE SYSTEMS, OR PROVIDE A MEANS OF HYDRAULIC ISOLATION BETWEEN THE SYSTEMS SUCH AS A CHECK VALVE BETWEEN THE CUP DRAIN AND THE MAIN DRAIN.

PROVIDE A SPLASH BLOCK BELOW DRAIN DISCHARGE, UNLESS DISCHARGING TO A PAVED OR CONCRETE SURFACE.

DO NOT LOCATE DRAINAGE DISCHARGE ADJACENT TO AN EXIT DOOR, NOR PERMIT DRAINAGE DISCHARGE TO CROSS THE PATH OF EGRESS FROM THE BUILDING. LOCATE DRAINAGE DISCHARGE TO NOT CAUSE SOIL EROSION WHEN MAIN

DRAIN OR INSPECTOR’S TEST CONNECTIONS ARE OPERATED DURING TESTING.

11. ALL PIPING IDENTIFICATION SHALL COMPLY WITH UFC 3-600-01.

12. THE FIRE SUPPRESSION SYSTEMS SHALL USE A DEDICATED NON-POTABLE WATER SUPPLY. THE DESIGN AND

INSTALLATION IS NOT REQUIRED TO INCLUDE A BACKFLOW PREVENTER.

13. WATER SUPPLY ENTRANCE TO BUILDING SHALL BE A CONTINUOUS SECTION OF WELDED STAINLESS STEEL TO A FLANGED FITTING A MINIMUM OF 12 INCHES A.F.F. WITHIN THE FIRE PROTECTION ROOM IN ACCORDANCE WITH UFC

4-211-01 SECTION 3-6.4.2.3.

14. TESTING OF THE AUTOMATIC SPRINKLER SYSTEM SHALL BE COMPLETED BY A QUALIFIED REPRESENTATIVE. TESTING SHALL BE IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.20. TESTING PROCEDURES SHALL BE WRITTEN PRIOR TO FINAL ACCEPTANCE AND BE REVIEWED BY THE EOR. FINAL ACCEPTANCE TESTING SHALL BE WITNESSED BY AHJ AND

EOR.

15. COORDINATE WITH MECHANICAL CONTRACTOR TO ENSURE THAT IF ANY OBSTRUCTIONS ARE INSTALLED, CODE

COMPLIANT COVERAGE IS PROVIDED.

16. THE CONTRACTOR MUST COORDINATE THE FIRE SUPPRESSION SYSTEM WITH THE STEEL JOIST FABRICATOR, AND THE STEEL JOIST FABRICATOR MUST SUBMIT A CERTIFIED LETTER TO THE ARCHITECT AND COPIED TO THE STRUCTURAL ENGINEER OF RECORD STATING THAT HE HAS RECEIVED SPRINKLER DRAWINGS WHERE APPLICABLE. THE STEEL JOIST FABRICATOR MUST DESIGN THE STEEL JOISTS FOR ADDITIONAL LOADING IMPOSED BY SPRINKLER MAIN SUPPLY

LINE AND BRANCHES WHERE APPLICABLE.

1. IBC 2024, AS REFERENCED AND AMENDED BY UFC 1-200-01

2. NFPA 1, NATIONAL FIRE CODE, 2024

3. NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022

4. NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR

APPURTENANCES, 2022

5. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021

6. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY

DAF FOAM SUNDOWN POLICY

7. MIL-STD-101C, COLOR CODE FOR PIPELINES, AUGUST 26, 2014

WET SPRINKLER RISER

OS&Y VALVE WITH TAMPER SWITCH

CHECK VALVE

TEST HEADER

FIRE DEPARTMENT CONNECTION

FLOW SWITCH

RESTRICTING ORIFICE

PRESSURE RELIEF VALVE

PRESSURE GAUGE

ALARM CHECK VALVE

CONTROL VALVE

WF

A

REMARKS: MINIMUM SPRINKLER OPERATION AREA AND K-FACTOR PER UFC 3-600-01 TABLE 9-3 AND UFC 4-211-01 SECTION 3-6.15.1.

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FX001

CWF

F

IR

E S

U P

P R

E S

S

IO

N G

E N

E R

A L N

O T

E S

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

FIRE SUPPRESSION LEGEND ABBREVIATIONS APPLICABLE CODES AND STANDARDS GENERAL FIRE SUPPRESSION NOTES

UNO UNLESS NOTED OTHERWISE

UL UNDERWRITERS LABORATORIES

UFC UNIFIED FACILITIES CRITERIA

SQ. FT. SQUARE FEET

PSI POUNDS PER SQUARE INCH

PIV POST INDICATOR VALVE

OS&Y OUTSIDE STEM AND YOKE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NO NORMALLY OPEN

NC NORMALLY CLOSED

GPM GALLONS PER MINUTE

FP FIRE PROTECTION

FM FACTORY MUTUAL

FDC FIRE DEPARTMENT CONNECTION

EOR ENGINEER OF RECORD

BLDG BUILDING

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

AHJ AUTHORITY HAVING JURISDICTION

AFF ABOVE FINISHED FLOOR

HAZARD CLASSIFICATION TABLE

HANGAR 0.20 5.6 OR 8.0 5000 500 45 130 200 WET 37'-0"

ORDINARY 0.20 8.0 2500 250 60 130 200 WET VARIES

LIGHT 0.10 5.6 1500 250 60 225 155 WET 10'-0"

HAZARD

DENSITY

(GPM/SQ.FT.)

K-FACTOR

DESIGN AREA

(SQ.FT.)

HOSE

GAL/MIN.

DURATION OF

SUPPLY MIN.

MAX. AREA

PER HEAD

(SQ.FT.)

TEMP. RATING SYSTEM TYPE

MAX. CEILING

HEIGHT

WEAPONS

RELEASE SHOP

WEAPONS LOAD

SHOP OFFICE

BREAK ROOM

WING WEAPONS

MANAGER

OFFICE

SHARED OFFICE

VEST 2

CLASSROOM

TEST & TRAINING

WEAPONS

ELEMENT SUPR

NCOIC SUPR

MECH 2

COMM

PPE STORAGE

ELEC

JAN CLOSET

STORAGE

111FIRE PROTECT

MECH 1

MEN

CWF HANGAR

LOBBY

CORRIDOR 1

CORRIDOR 2

VEST 1

WOMEN

TOOL CRIB

A MKJHGFEDCB

A12

FX401

N

7.5

5.1

3.1

6.2

2.1

EXTERIOR

COVERED

STORAGE

EXTERIOR

MECHANICAL

YARD

EXTERIOR

COVERED

STORAGE

GUN

SERVICING/CLEANING

OFFICE

CORRIDOR 4

124B

CORRIDOR 3

124A

LIGHT HAZARD: 0.10 GPM OVER 1500 SQ. FT.

K-FACTOR MINIMUM = 5.6

ORDINARY HAZARD: 0.20 GPM OVER 2500 SQ. FT.

K-FACTOR MINIMUM = 8.0

HANGAR 0.20 OVER 5000 SQ. FT.

K-FACTOR MINIMUM = 5.6 OR 8.0

WET SPRINKLER RISER

OS&Y VALVE WITH TAMPER SWITCH

CHECK VALVE

TEST HEADER

FIRE DEPARTMENT CONNECTION

FLOW SWITCH

RESTRICTING ORIFICE

PRESSURE RELIEF VALVE

PRESSURE GAUGE

ALARM CHECK VALVE

CONTROL VALVE

WF

A

B C

A

PLAN

NORTH

8' 16' 32'0'

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

GRAPHIC SCALE

KEY PLAN

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FX101

CWF

F

IR

E S

U P

P R

E S

S

IO

N H

A Z

A R

D C

L A

S S

IF

IC

A T

IO

N

F L O

O R

P L A

N

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

SCALE: 1/16" = 1'-0"

A8

FIRE SUPPRESSION HAZARD CLASSIFICATION FLOOR PLAN - OVERALL

1. REFER TO SHEET FX001 FOR GENERAL NOTES,

APPLICABLE CODES, ABBREVIATIONS, AND SYMBOLS.

2. MINIMUM SPRINKLER OPERATION AREA AND K-

FACTOR ON SHEET LEGEND PER UFC 3-600-01 TABLE

9-3.

SHEET NOTES

LEGEND

KEY NOTES

USE LISTED AND APPROVED EXTENDED

COVERAGE DRY SIDEWALL SPRINKLER HEADS

F

FIRE PROTECT

A12

FX401

' - 0

MAIN DRAIN TO EXTERIOR

8" SUPPLY MAIN

FINISH FLOOR

0'-0"

BY DIVISION 21BY DIVISION 33

PROVIDE SLEEVE FOR SUPPLY MAIN AT

PENETRATION THROUGH CONCRETE

SLAB PER NFPA 13, SECTION 18.4.3

PROVIDE 8" SUPPLY MAIN

(ONE PIECE STAINLESS STEEL PIPE)

SEE CIVIL DRAWINGS

FOR CONTINUATION

BUTTERFLY VALVE

W/TAMPER

RISER CHECK VALVE

WATER FLOW SWITCH

CONCENTRIC REDUCER

CHECK VALVE

F R

O M

R E

M O

T E

F D

C

T O

C W

F H

A N

G A

R

T O

B U

IL

D

IN

G

CHECK VALVE

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FX401

CWF

F

IR

E S

U P

P R

E S

S

IO

N E

N L A

R G

E D

P L A

N S

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

SCALE: 1/4" = 1'-0"

H12

SPRINKLER RISER ENLARGED PLAN

SCALE: NTS

H7

3D SPRINKLER RISER DETAIL

SCALE: 1/4" = 1'-0"

A12

SPRINKLER RISER SECTION

1. PROVIDE AN ADDRESSABLE COMBINATION FIRE ALARM AND MASS NOTIFICATION SYSTEM IN

ACCORDANCE WITH THE CURRENT EDITIONS OF UFC 3-600-01, UFC 4-021-01, UFC 4-211-01, NFPA 72, ECB 2018-17, AND SPECIFICATION 28 31 76.

2. INSTALLING CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS THAT MAY AFFECT THE SYSTEM

INSTALLATION OR COMPLIANCE WITH THE APPLICABLE CODES AND MUST NOTIFY THE

CONTRACTING OFFICER PRIOR TO BEGINNING WORK.

3. THE LOCATION OF DEVICES SHOWN IS SUGGESTED. ACTUAL LOCATIONS TO BE DETERMINED BY

INSTALLING CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED HEREIN.

4. RF TRANSCEIVER OPERATION REQUIRES AUTHORIZATION FROM THE BASE INSTALLATION

MANAGER.

5. FIRE ALARM CONTROL UNITS MUST NOT BE USED AS A RACEWAY FOR ROUTING CONDUCTORS

WHICH WILL NOT BE TERMINATED IN THAT CONTROL UNIT. PROVIDE 1/4 INCH SEPARATION

BETWEEN POWER-LIMITED AND NON-POWER LIMITED CIRCUITS. CONDUCTOR INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 70, 760.48, AND NFPA 70, 760.136(D) WHERE POWER LIMITED AND NON-

POWER LIMITED WIRING ENTER THE SAME ENCLOSURE.

6. BACKUP BATTERY CAPACITY SHALL BE FOR 48 HOURS STANDBY AND 15 MINUTES OF ALARM.

7. WIRING MUST BE MINIMUM CLASS "B" AND INSTALLED IN METALLIC CONDUITS NO LESS THAN 3/4"

AND NOT EXCEED FILL RATES AS OUTLINED IN NFPA 70.

8. CONDUCTOR SIZING NOT LESS THAN 18 AWG FOR SLC, 16 AWG FOR AUDIO, AND 14 AWG FOR NAC.

CONSISTENTLY COLOR COORDINATE CONDUCTORS THROUGH THE SYSTEM IN RELATION TO

DEVICES THEY FEED (E.G. SLC -BLACK/RED,STROBE - YELLOW/BLUE).

9. RUN CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. THE USE OF WIRE NUTS, CRIMPED

CONNECTORS, OR TWISTING CONDUCTORS ARE PROHIBITED. UTILIZE TERMINAL STRIPS WHERE

CONDUCTORS CANNOT BE DIRECTLY TERMINATED AT THE DEVICE. ALL DEVICES MUST HAVE

SCREW TERMINALS WHERE DEVICES ARE ONLY PROVIDED WITH PIGTAILS FROM THE

MANUFACTURER, PIGTAILS MUST BE LANDED ON TERMINAL STRIPS MOUNTED WITHIN THE

JUNCTION BOX.

10. FIRE ALARM CONDUITS, JUNCTION BOXES, ASSOCIATED WIRING, AND ACCESSORIES MUST NOT BE

INSTALLED AT OR BELOW 24 INCH A.F.F UNLESS SPECIFICALLY DIRECTED BY CODE OR

MANUFACTURER.

11. MANUAL PULL STATIONS MUST BE PROVIDED AT ALL EXITS. LOCATIONS MUST BE WITHIN 5 FT OF

THE EXIT DOOR.

12. PROVIDE ADDRESSABLE DOUBLE-ACTION TYPE MANUAL PULL STATIONS WITH KEY RESET. KEY

MUST BE SAME AS FACU/ACU CABINET.

13. SMOKE DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE LOCATED

DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN AIR SUPPLY

SYSTEMS HAVING A CAPACITY GREATER THAN 2000 CFM/MIN. (NFPA 90A 2024 SECTION11.4.2.1).

14. FIRE ALARM/MASS NOTIFICATION STROBES AND/OR SPEAKER/STROBES MUST HAVE A CLEAR LENS

AND BE MARKED "ALERT."

15. CONNECT BUILDING FACU/ACU TO EXISTING BASE MONACO D-21 REPORTING SYSTEM. PROVIDE

COMPATIBLE TRANSCEIVER FOR CONNECTION TO BASE REPORTING SYSTEM.

16. SPEAKERS IN THE VICINITY OF THE FACU/ACU AND LOC SHALL NOT CREATE ACOUSTICAL

FEEDBACK OR INTERFERE WITH THE ABILITY TO DELIVER LIVE VOICE MESSAGES.

17. MEET THE FOLLOWING INTELLIGIBILITY CRITERIA:

A. ACHIEVE A CIS SCORE OF 0.80 IN ALL AREA OF EACH ROOM MEASURED AT 5 FT AFF.

B. A LESSER CIS IS PERMITTED IN AREAS OF THE BUILDING WITH EXCESSIVE SOUND REFLECTIONS, SUCH AS ROOMS WITH HARD SURFACES (METAL, TILE, OR CONCRETE), WHERE THE OCCUPANT

CAN WALK NO MORE THAN 33 FT TO A LOCATION IN THE SAME ROOM THAT ACHIEVES THE MINIMUM

CIS (0.8).

C. A LESSER CIS IS PERMITTED IN NORMALLY UNOCCUPIED ROOMS OF THE BUILDING, WHERE THE OCCUPANT CAN WALK NO MORE THAN 50 FT TO A LOCATION IN THE SAME ROOM THAT ACHIEVES

THE MINIMUM CIS (0.8). NORMALLY UNOCCUPIED ROOMS ARE CONSIDERED TO BE STORAGE

ROOMS, MECHANICAL / ELECTRICAL ROOMS, COMMUNICATION CLOSETS, AND FIRE PROTECTION

ROOMS.

D. THE HANGAR BAY SHALL BE MODELED DURING DESIGN FOR ACOUSTICAL INTELLIGIBILITY. ALL AREAS WITHIN THE ROOM (BAY) IN THE MODEL AND AT TESTING SHALL BE WITHIN 50FT OF AN AREA

WITH A 0.7 (0.65 ROUNDED) CIS.

18. ACTIONS TAKEN AT THE FACU/ACU TAKE PRECEDENCE OVER ACTIONS TAKEN ELSEWHERE.

19. MINIMUM STROBE CANDELA SHOWN FOR REFERENCE ONLY. ACTUAL CANDELA MUST BE

DETERMINED BY INSTALLING CONTRACTOR BASED ON LAYOUT. ENSURE STROBES IN THE SAME

FIELD OF VIEW FLASH IN SYNCHRONIZATION.

20. VISIBLE NOTIFICATION IS REQUIRED IN ALL NORMALLY OCCUPIED, PUBLIC AND COMMON USE

AREAS (BREAK ROOMS, REST ROOMS, CORRIDORS, CONFERENCE ROOMS, OFFICES GREATER

THAN 2 OCCUPANTS).

21. VISIBLE NOTIFICATION IS REQUIRED IN ALL NORMALLY UNOCCUPIED AREAS GREATER THAN 900 SQ.

FT. OR IF HEARING PROTECTION IS REQUIRED.

22. PROVIDE VISUAL NOTIFICATION FOR BATHROOMS SERVING GREATER THAN SINGLE PERSON

OFFICES PER UFC 3-600-01 SECTION 9-18.6.3(K).

23. ANY ALARM STATUS MUST SHUTDOWN HVLS FANS PER UFC 3-600-01, SECTION 7-6.

24. REFER TO ARCHITECTURAL DRAWINGS FOR INFORMATION ON ROOM DIMENSIONS, CEILING

HEIGHTS, AND OTHER PHYSICAL MEASUREMENTS.

25. TESTING OF THE FACU/ACU SYSTEMS SHALL BE COMPLETED BY AN AUTHORIZED FACTORY

REPRESENTATIVE. TESTING SHALL BE PERFORMED IN ACCORDANCE WITH UFC 4-211-01 SECTION

3-6.20. TESTING PROCEDURES SHALL BE WRITTEN PRIOR TO FINAL ACCEPTANCE AND BE

REVIEWED BY THE EOR. FINAL ACCEPTANCE TESTING SHALL BE WITNESSED BY AHJ AND THE EOR.

26. FLEXIBLE CONDUIT IS PERMITTED ONLY WHEN TERMINATING AT FIRE SUPPRESSION EQUIPMENT OR IN DEVICES MOUNTED IN MOVABLE CEILING TILES. THE LENGTH OF FLEXIBLE CONDUIT IS LIMITED TO A MAXIMUM CONDUIT LENGTH OF 6 FT. IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.19.5.

27. CONDUIT ENTRY INTO THE TOP OF ANY CONTROL PANEL IS PROHIBITED.

28. ALL DEVICES MOUNTED INSIDE HANGAR BAY SHALL HAVE A MINIMUM NEMA 4 RATING.

29. ALL DISCONNECTS OF PRIMARY POWER CIRCUITS FOR THE FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 72, CHAPTER 10.6.5.2, AND BE MARKED IN RED AND NOT OBSCURE MANUFACTURER

MARKINGS.

30. REFERENCE SHEETS EP109, EP110, EP111, AND EP301 FOR LOCATIONS OF ELECTRICAL HAZARD CLASSIFIED AREAS. COMPONENTS AND SUPPORTING INSTALLATION INSTALLED WITHIN ELECTRICAL

HAZARD CLASSIFIED AREAS MUST COMPLY WITH REQUIREMENTS OF NEC.

1. IBC 2021, AS REFERENCED AND AMENDED BY UFC 1-200-01, CHANGE 2

2. NFPA 70, NATIONAL ELECTRICAL CODE (NEC), 2023

3. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022

4. UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, CHANGE 2, APRIL 12, 2021

5. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021

6. UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, CHANGE 2, JULY 30, 2022

7. UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE 1, JANUARY 1, 2010

8. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY

DAF FOAM SUNDOWN POLICY

9. ECB 2018-17, NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS NOTIFICATION

SYSTEMS, OCTOBER 25, 2018

10. ANG ETL 15-01-03, FIRE PROTECTION DESIGN GUIDANCE, MAY 1, 2015

FACU/ACU FIRE ALARM CONTROL UNIT

LOCAL OPERATOR CONSOLE

PHOTOELECTRIC SMOKE DETECTOR

DUCT SMOKE DETECTOR

MANUAL PULL STATION

ADDRESSABLE INPUT MODULE

ADDRESSABLE OUTPUT MODULE

SPEAKER/STROBE, CEILING MOUNT

SPEAKER ONLY

STROBE ONLY, CEILING MOUNT

STROBE ONLY, WALL MOUNT

HORN/STROBE, OUTDOOR RATED

SURGE PROTECTION DEVICE

ANTENNA

DOCUMENT STORAGE BOX

WATER FLOW SWITCH

VALVE SUPERVISORY SWITCH

END-OF-LINE RESISTOR

RELAY

LOW TEMPERATURE DETECTOR

EMERGENCY EYE-WASH STATION

BUILDING KEY LOCK BOX

CM

CD

WP

SPD

LOC

DOC

S

F

AOM

AIM

S

S

M

WF

VS

EOL

RL

LT

M

EEWS

LBX

SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:

DRAWING SEQUENCE NUMBER INDICATES

WHERE TITLE IS LOCATED (MAY NOT BE

PRESENT IF CALLOUT AND TITLE ARE ON THE

SAME DRAWING)

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

ONE OR TWO CHARACTER DISCIPLINE

DESIGNATOR (MAY NOT BE PRESENT IF

CALLOUT AND TITLE ARE ON DRAWINGS

WITHIN THE SAME DISCIPLINE)

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

WALL SECTION CALLOUT EXAMPLE:

DETAIL CALLOUT EXAMPLE:

ELEVATION CALLOUT EXAMPLE:

SECTION, DETAIL, AND ELEVATION TITLE EXAMPLE:

EXTERIORINTERIOR

NORTH ARROW EXAMPLE:

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

BUILDING SECTION CALLOUT EXAMPLE:

VIEW REFERENCE EXAMPLE:

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

DETAIL IS DRAWN

A1

A401

A1

A311

A1

A311

A1

A301

A1

A301

A1

A401

A1

A201

A751

A1

A3

A4A2

VIEW TITLE

A1

VIEW TITLE

VIEW SCALE

VIEW SCALE BAR

SCALE: 1/8" = 1'-0" 0 4' 8' 16'

PLAN

NORTH

PLAN NORTH

TRUE NORTH

NORTH ARROW INDICATING PLAN

NORTH AND TRUE NORTH

A1

A311

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N F

IL

E

N A

M E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

FA001

CWF

F

IR

E A

L A

R M

G E

N E

R A

L N

O T

E S

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A C

P

E T

E R

S O

N

A B

A B

A

IA

N

S G

E O

R G

E

R M

E D

E

IR

O S

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-F .R

V T

B-3 100% DESIGN SUBMITTAL

ROY MEDEIROS

V VOLT

UNO UNLESS NOTED OTHERWISE

UL UNDERWRITERS LABORATORIES

UFC UNIFIED FACILITIES CRITERIA

UCMS UTILITY CENTRAL MONITORING SYSTEM

SQ. FT. SQUARE FEET

SLC SIGNALING LINE CIRCUIT

RTS REMOTE TEST STATION

RMC RIGID METAL CONDUIT

RF RADIO FREQUENCY

RDU REMOTE DISPLAY UNIT

PIV POST INDICATOR VALVE

OS&Y OUTSIDE STEM AND YOKE

OCP OVERCURRENT PROTECTION

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NC NORMALLY CLOSED

NAC NOTIFICATION APPLIANCE CIRCUIT

MNS MASS NOTIFICATION SYSTEM

LOC LOCAL OPERATOR CONSOLE

HZ HERTZ

HVLS HIGH VOLUME LOW SPEED

HVAC HEATING VENTILATION AND AIR CONDITIONING

FP FIRE PROTECTION

FACU FIRE ALARM CONTROL UNIT

FAA FIRE ALARM ANNUNCIATOR

FA FIRE ALARM

EX EXPLOSION PROOF

EOR ENGINEER OF RECORD

EOLR END-OF-LINE RESISTOR

EMT ELECTRIC METALLIC TUBING

DC DIRECT CURRENT

CO CARBON MONOXIDE

CIS COMMON INTELLIGIBILITY SCALE

CD CANDELA

BLDG BUILDING

AWG AMERICAN WIRE GAUGE

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

ARM ADDRESSABLE RELAY MODULE

AOM ADDRESSABLE OUTPUT MODULE

AMP AMPLIFIER BOOSTER PANEL

AIM ADDRESSABLE INPUT MODULE

AHU AIR HANDLING UNIT

AHJ AUTHORITY HAVING JURISDICTION

AFF ABOVE FINISHED FLOOR

ACU AUTONOMOUS CONTROL UNIT

CALLOUT IDENTIFICATION FIRE ALARM LEGEND ABBREVIATIONS APPLICABLE CODES AND STANDARDS GENERAL FIRE ALARM NOTES

WEAPONS

RELEASE SHOP

WEAPONS LOAD

SHOP OFFICE

BREAK ROOM

WING WEAPONS

MANAGER

OFFICE

SHARED OFFICE

VEST 2

CLASSROOM

TEST & TRAINING

WEAPONS

ELEMENT SUPR

NCOIC SUPR

MECH 2

COMM

PPE STORAGE

ELEC

JAN CLOSET

STORAGE

FIRE PROTECT

MECH 1

MEN

CWF HANGAR

LOBBY

CORRIDOR 1

CORRIDOR 2

VEST 1

WOMEN

A MKJHGFEDCB

M A

T C

H L

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .