Attach-3_JAXF35CWF-100P GENERAL FP ELECT TELE DRAWINGS VOLUME 2 OF 3.pdf
PDF 31 MB Posted
- Attached to
- F-35 CONSTRUCT COMBINED WEAPONS FACILITY Federal contract opportunity
- Solicitation number
- W50S6Y-25-B-A004
About this file
This file appears to be Volume 2 of 3 containing general electrical and telecommunications drawings for the F-35 Combined Weapons Facility construction project at Jacksonville International Airport. While the specific drawing details are not provided in the shared content, this would typically include technical drawings and specifications for the electrical and telecommunications systems to be installed in the 22,696 square-foot facility, which includes a Hangar Bay, weapons and release systems shops, administrative offices, classrooms, break room, and restrooms.
This document is referenced as part of solicitation W50S6Y-25-B-A004, a small business set-aside construction project with a magnitude of $10M-$25M being managed by the Florida Army National Guard. The drawings would serve as technical guidance for contractors bidding on the electrical and telecommunications portions of the construction project.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
TASK ORDER NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M A
R K
D E
S C
R
IP
T
IO
N
NOT FOR
CONSTRUCTION
F
IL
E N
A M
E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
Florida Air
National Guard ®
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
CLIENT LOGO
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
G-001
CWF
C O
V E
R S
H E
E T
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A J G
A R
Z A
R M
A R
T
IN
E Z
S
B
S G
E O
R G
E
R D
E L
A R
O S
A
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-A .R
V T
W50S6Y24F0001
FA8903-21-D-0011
JANUARY 2025
VOLUME 2 OF 3
JACKSONVILLE, FLORIDA
F-35 CONSOLIDATED WEAPONS FACILITY
B-3 100% DESIGN SUBMITTAL
W50S6Y24F0001
W S
Y
F
CWF LOCATIONPROJECT LOCATION
NN
PROJECT # LSGA239001
STANLEY GEORGE
T
CETIHCRADER
ET
SI
G E
R
FOETAT
S
RO
EG
SLGUOD
YEL
NAT S
A
E G
AR102462
F L OR I D
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
NOT FOR
CONSTRUCTION
F
IL
E N
A M
E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
G-003
CWF
IN
D
E X
O F
D R
A W
IN
G
S
V O
L U
M E o f
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A J G
A R
Z A
R M
A R
T
IN
E Z
S
B
S G
E O
R G
E
R D
E L
A R
O S
A
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-A .R
V T
B-3 100% DESIGN SUBMITTAL
VOLUME 2 of 3
GENERAL
SHEET ID SHEET TITLE
G-001 COVER SHEET
G-002 INDEX OF DRAWINGS (VOLUME 1 of 3)
G-003 INDEX OF DRAWINGS (VOLUME 2 of 3)
G-004 INDEX OF DRAWINGS (VOLUME 3 of 3)
FIRE PROTECTION
SHEET NO. SHEET TITLE
FL001 CODE ANALYSIS
FL101 CODE COMPLIANCE SITE PLAN
FL102 LIFE SAFETY FLOOR PLAN
FL103 LIFE SAFETY EGRESS FLOOR PLAN - OVERALL
FL104 LIFE SAFETY EGRESS FLOOR PLAN - AREA A
FL105 LIFE SAFETY EGRESS FLOOR PLAN - AREA B
FL106 LIFE SAFETY EGRESS FLOOR PLAN - AREA C
FX001 FIRE SUPPRESSION GENERAL NOTES
FX101 FIRE SUPPRESSION HAZARD CLASSIFICATION FLOOR PLAN
FX401 FIRE SUPPRESSION ENLARGED PLANS
FA001 FIRE ALARM GENERAL NOTES
FA101 FIRE ALARM FLOOR PLAN - OVERALL
FA102 FIRE ALARM FLOOR PLAN - AREA A
FA103 FIRE ALARM FLOOR PLAN - AREA B
FA104 FIRE ALARM FLOOR PLAN - AREA C
FA501 FIRE ALARM DETAILS
FA502 FIRE ALARM MATRIX
FA601 FIRE ALARM RISER DIAGRAM
ELECTRICAL
SHEET NO. SHEET TITLE
E-001 ELECTRICAL SYMBOL LEGENDS
E-002 GENERAL ELECTRICAL ABBREVIATIONS AND NOTES
EG101 GROUNDING PLAN - OVERALL
EG102 GROUNDING PLAN - AREA A
EG103 GROUNDING PLAN - AREA B
EG104 GROUNDING PLAN - AREA C
EG105 LIGHTNING PROTECTION PLAN
EG106 LIGHTNING PROTECTION PLAN - AREA A
EG107 LIGHTNING PROTECTION PLAN - AREA B
EG108 LIGHTNING PROTECTION PLAN - AREA C
EG501 GROUNDING DETAILS
EG502 GROUNDING DETAILS
EG503 GROUNDING DETAILS
EG504 GROUNDING RISER DIAGRAM
EG511 LIGHTNING PROTECTION DETAILS
EL101 LIGHTING PLAN - OVERALL
EL102 LIGHTING PLAN - AREA A
EL103 LIGHTING PLAN - AREA B
EL104 LIGHTING PLAN - AREA C
EL105 ROOF LIGHTING PLAN
EL501 LIGHTING DETAILS
EL502 LIGHTING DETAILS
EL503 LIGHTING DETAILS
EL504 LIGHTING DETAILS
EL505 LIGHTING DETAILS
EL601 LIGHTING FIXTURE SCHEDULE
EL602 LIGHTING CONTROLS SCHEDULE
EP101 POWER PLAN - OVERALL
EP102 POWER PLAN - AREA A
EP103 POWER PLAN - AREA B
EP104 POWER PLAN - AREA C
EP105 MECH POWER PLAN - OVERALL
EP106 MECH POWER PLAN - AREA A
EP107 MECH POWER PLAN - AREA B
EP108 MECH POWER PLAN - AREA C
EP109 HAZARD CLASSIFICATION PLAN
EP110 HAZARD CLASSIFICATION PLAN - AREA A
EP111 HAZARD CLASSIFICATION PLAN - AREA B
EP301 HAZARD CLASSIFICATION SECTION
EP302 ELEVATION PLANS
EP401 ENLARGED POWER PLANS
EP501 POWER DETAILS
EP502 POWER DETAILS
EP601 PANELBOARD SCHEDULES
EP602 PANELBOARD SCHEDULES
EP603 PANELBOARD SCHEDULES
EP604 ELECTRICAL EQUIPMENT SCHEDULE
EP610 FEEDER SCHEDULE
EP701 SINGLE LINE DIAGRAM
TELECOM
SHEET NO. SHEET TITLE
T-001 GENERAL TELECOM SYMBOLS, ABBREVIATIONS AND NOTES
T-111 TELECOM PLAN - OVERALL
T-112 TELECOM PLAN - AREA A
T-113 TELECOM PLAN - AREA B
T-114 TELECOM PLAN - AREA C
T-401 TELECOM ENLARGED PLANS
T-501 TELECOM DETAILS
T-502 CABLE TRAY DETAILS
T-503 WIRING DETAILS
T-504 TELECOM DETAILS
T-505 TELECOM DETAILS
T-601 TELECOM RISER DIAGRAM
TY001 IDS AND ESS SYSTEM NOTES
TY101 SECURITY PLAN - OVERALL
TY102 SECURITY PLAN - AREA A
TY103 SECURITY PLAN - AREA B
TY104 SECURITY PLAN - AREA C
TY501 SECURITY DOOR DETAILS
TY502 SECURITY DETAILS
TY503 SECURITY RISER DIAGRAM AND SCHEDULE
STANLEY GEORGE
T
CETIHCRADER
ET
SI
G E
R
FOETAT
S
RO
EG
SLGUOD
YEL
NAT S
A
E G
AR102462
F L OR I D
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL001
CWF
C O
D E
A N
A L Y
S
IS
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
1. 2021 INTERNATIONAL BUILDING CODE (IBC), AS REFERENCED AND AMENDED BY UFC 1-200-01, CHANGE 2
2. NFPA 1, FIRE CODE, 2024
3. NFPA 10, STANDARD FOR PORTABLE FIRE EXTINGUISHERS, 2022
4. NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022
5. NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, 2021
6. NFPA 70, NATIONAL ELECTRICAL CODE (NEC), 2023
7. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022
8. NFPA 80, STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES, 2022
9. NFPA 90A, STANDARD FOR THE INSTALLATION OF AIR-CONDITIONING AND VENTILATING SYSTEMS, 2021
10. NFPA 101, LIFE SAFETY CODE, 2024
11. NFPA 220, STANDARD ON TYPES OF BUILDING CONSTRUCTION, 2021
12. NFPA 400, HAZARDOUS MATERIALS CODE, 2022
13. NFPA 409, STANDARD ON AIRCRAFT HANGARS, 2022
14. UFC 1-200-01, DoD BUILDING CODE (GENERAL BUILDING REQUIREMENTS), CHANGE 2, JUNE 12, 2023
15. UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, CHANGE 2, APRIL 12, 2021
16. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021
17. UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, CHANGE 2, JULY 30, 2022
18. UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE 1, JANUARY 1, 2010
19. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY DAF FOAM SUNDOWN POLICY
20. ENGINEERING AND CONSTRUCTION BULLETIN, NO. 2018-17, NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS
NOTIFICATION SYSTEMS, OCTOBER 25, 2018
21. ANGETL 10-03 AIR NATIONAL GUARD DESIGN OBJECTIVES AND PROCEDURES, APRIL 16, 2010
22. ANGETL 15-01, AIR NATIONAL GUARD DESIGN POLICY, MAY 1, 2015
23. ANGETL 15-01-03, FIRE PROTECTION DESIGN GUIDANCE, MAY 1, 2015
24. F-35 LIGHTNING II FACILITIES REQUIREMENTS DOCUMENTS, SEPTEMBER 2023
THE BUILDING IS A NON-SEPARATED MIXED-USE BUILDING PER IBC 508.3 WITH THE FOLLOWING OCCUPANCIES:
A-3, ASSEMBLY PER IBC SECTION 303.4 AND ASSEMBLY PER NFPA 101 SECTION 6.1.2.1
B, BUSINESS PER IBC SECTION 304.1 AND BUSINESS PER NFPA 101 SECTION 6.1.11.1
F-1, MODERATE HAZARD INDUSTRIAL PER IBC SECTION 306.2 AND INDUSTRIAL PER NFPA 101 SECTION 6.1.12.1 S-1, MODERATE HAZARD STORAGE PER IBC SECTION 311.2 AND STORAGE PER NFPA 101 SECTION 6.1.13.1
SEE OCCUPANT LOAD IN UFC 3-600-01, TABLE 10-4 AND NFPA 101, TABLE 7.3.1.2 AND OCCUPANT LOAD TABLE ON THIS SHEET.
THE FACILITY WILL NOT EXCEED THE ALLOWABLE AREA OR HEIGHT FOR TYPE IIB CONSTRUCTION FOR A SINGLE STORY
ABOVE GRADE BUILDING EQUIPPED WITH AN AUTOMATIC FIRE SPRINKLER SYSTEM.
TYPE IIB (NON FIRE-RESISTANT RATED, NONCOMBUSTIBLE CONSTRUCTION) (IBC SECTION 602.2)
OCCUPANT LOAD FACTORS PER NFPA 101 TABLE 7.3.1.2 AND UFC 3-600-01 TABLE 10-1.
MINIMUM INTERIOR AND CEILING FINISH AND FLOOR FINISH REQUIREMENTS PER NFPA 101 TABLE A.10.2.2
OCCUPANT LOAD
CODE OF RECORD
BUILDING OCCUPANCY CLASSIFICATION
ALLOWABLE AREA AND HEIGHT
CONSTRUCTION TYPE
PASSIVE FIRE PROTECTION
OPENING PROTECTION
INTERIOR FINISH
FIRE EXTINGUISHERS
FIRE SUPPRESSION
FIRE ALARM
TOTAL 20703 233
WEAPONS LOAD STORAGE BAY 132 STORAGE 4988 500 GROSS 10
WEAPONS RELEASE SHOP 131 INDUSTRIAL 1182 100 GROSS 12
GUN SERVICING/CLEANING 130 STORAGE 581 500 GROSS 2
TOOL CRIB 129 STORAGE 347 500 GROSS 1
SECURITY STOR 128 STORAGE 82 500 GROSS 1
MECH 2 127 STORAGE 175 500 GROSS 1
NCOIC SUPR 126 BUSINESS 126 150 GROSS 1
WEAPONS ELEMENT SUPR 125 BUSINESS 125 150 GROSS 1
CORRIDOR 4 124B BUSINESS 436 150 GROSS 3
CORRIDOR 3 124A BUSINESS 117 150 GROSS 1
CORRIDOR 2 124 BUSINESS 274 150 GROSS 2
WEAPONS LOAD SHOP OFFICE 123 BUSINESS 1493 50 GROSS 30
TEST & TRAINING 122 BUSINESS 486 15 NET 33
BREAK ROOM 120 BUSINESS 222 15 NET 15
OFFICE 119 BUSINESS 125 150 GROSS 1
WING WEAPONS MANAGER 118 BUSINESS 130 150 GROSS 1
COMM 117 STORAGE 127 500 GROSS 1
ELEC 116 STORAGE 134 500 GROSS 1
FIRE PROTECT 115 STORAGE 114 500 GROSS 1
MECH 1 114 STORAGE 508 500 GROSS 2
PPE STORAGE 113 STORAGE 104 500 GROSS 1
JAN CLOSET 112 STORAGE 35 500 GROSS 1
STORAGE 111 STORAGE 60 300 GROSS 1
MEN 110 LOCKERS 425 50 GROSS 9
WOMEN 109 LOCKERS 219 50 GROSS 5
CLASSROOM 108 ASSEMBLY 1012 15 NET 68
CORRIDOR 1 107 BUSINESS 381 150 GROSS 3
LOBBY 106 BUSINESS 104 15 NET 7
VEST 1 105 BUSINESS 132 150 GROSS 1
OFFICE 104 BUSINESS 123 150 GROSS 1
SHARED OFFICE 103 BUSINESS 242 150 GROSS 2
VEST 2 102 BUSINESS 51 150 GROSS 1
CWF HANGAR 101 STORAGE 6043 500 GROSS 13
ROOM NAME
ROOM
NUMBER
FUNCTION/USE
AREA (NET
SQ. FT.)
OCCUPANT LOAD
FACTOR (SF/PER.)
CALCULATED
OCCUPANT LOAD
CLASS A - FLAME SPREAD INDEX 0-25; SMOKE DEVELOPED INDEX 0-450
CLASS B - FLAME SPREAD INDEX 26-75; SMOKE DEVELOPED INDEX 0-450
CLASS C - FLAME SPREAD INDEX 76-200; SMOKE DEVELOPED INDEX 0-450
CLASS I - CRITICAL RADIANT FLUX, NOT LESS THAN 0.45 W/SQ.CM.
CLASS II - CRITICAL RADIANT FLUX, NOT LESS THAN 0.22 W/SQ.CM. BUT LESS THAN 0.45 W/SQ.CM.
TOTAL 20,708
S-1 70,000 17,500 17,500 x .75 = 13,125 83,125 13,302
F-1 62,000 15,500 15,500 x .75 = 11,625 73,625 1,182
B 92,000 23,000 23,000 x .75 = 17,250 109,250 5,210
A-3 38,000 9,500 9,500 x .75 = 7,125 45,125 1,014
SINGLE STORY
WITH SPRINKLER
NON-
SPRINKLER
OCCUPANCY AREA (SQ. FT.) (IBC TABLE 506.2)
FRONTAGE INCREASE (SQ.
FT.) (IBC SECTION 506.3)
ALLOWABLE AREA (SQ. FT.)
(IBC SECTIONS 506.2.2 AND
508.4.2)
ACTUAL AREA
NET (SQ. FT.)
ROOF CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 0
FLOOR CONSTRUCTION AND ASSOCIATED SECONDARY MEMBERS 0 0
FIRE SEPARATION DISTANCE OF 30 FEET OR MORE 0 0
FIRE SEPARATION DISTANCE OF AT LESAT 10 FEET BUT LESS THAN 30 FEET 0 0
FIRE SEPARATION DISTANCE OF AT LEAST 5 FEET BUT LESS THAN 10 FEET 1 1
FIRE SEPARATION DISTANCE LESS THAN 5 FEET 1 2
NONBEARING EXTERIOR WALLS:
BEARING WALLS - INTERIOR AND EXTERIOR 0 0
PRIMARY STRUCTURAL FRAME 0 0
TYPE IIB - BUILDING ELEMENT
FIRE-RESISTANCE
RATING GROUP A-3, B
(HOURS)
FIRE-RESISTANCE
RATING GROUP
F-1, S-1 (HOURS)
MECHANICAL ROOM (127) SMOKE PARTITION NFPA 101 SECTION 38.3.2.1 AND SECTION 8.7.1.2
MECHANICAL ROOM (114) SMOKE PARTITION NFPA 101 SECTION 38.3.2.1 AND SECTION 8.7.1.2
CWF HANGAR (101) 1 HR FIRE BARRIER UFC 4-211-01 SECTION 3-3.1.3
FIRE PROTECTION ROOM (115) 1 HR FIRE BARRIER UFC 4-211-01 SECTION 3-6.7
ROOM RATING (HOUR) CODE SECTION
SMOKE
PARTITION
N/A N/A N/A
CLASS II FOR AIR TRANSFER
OPENINGS ONLY
FIRE
BARRIER
1 HR 0.75 HR
1.5 HR FOR AIR
TRANSFER OPENINGS
ONLY
N/A
TYPE OF
ASSEMBLY
REQUIRED
ASSEMBLY
RATING (HOURS)
MINIMUM FIRE DOOR AND FIRE
SHUTTER ASSEMBLY RATINGS
(HOURS) (NFPA 101 TABLE 8.3.3.2.2)
MINIMUM FIRE DAMPER
RATINGS (HOURS) (NFPA
90A SECTION 9.2.1.1)
MINIMUM SMOKE DAMPER
RATING (HOURS) (NFPA 101
SECTIONS 8.4.6.2 AND 8.4.6.3)
MEANS OF EGRESS
EXITS AND EXIT CAPACITY:
THE EXITS ARE REQUIRED TO BE SEPARATED FROM EACH OTHER BY AT LEAST ONE-THIRD THE DIAGONAL OF THE FLOOR
AREA IN WHICH THEY SERVE (NFPA 101 SECTION 7.5.1.3.3).
CWF HANGAR AREA:
OVERALL DIAGONAL: 111'-7"
REMOTENESS OF EXITS: 92'-0"
OFFICE AREA:
OVERALL DIAGONAL: 120'-9"
REMOTENESS OF EXITS: 92'-3"
WEAPONS LOAD STORAGE BAY AREA:
OVERALL DIAGONAL: 107'-6"
REMOTENESS OF EXITS: 99'-4"
COMMON PATH, DEAD-END AND TRAVEL DISTANCE (BY OCCUPANCY) NFPA 101 TABLE A.7.6
FLOOR
CLASS I
OR II
CLASS I OR II N/A
CLASS I
OR II
CLASS I OR II N/A
CLASS I OR
II
CLASS I OR II N/A
WALL/
CEILING
A A OR B A, B, OR C A OR B A OR B A, B, OR C A OR B A, B, OR C A, B, OR C
EXITS
EXIT ACCESS
CORRIDORS
OTHER
SPACES
EXITS
EXIT ACCESS
CORRIDORS
OTHER
SPACES
EXITS
EXIT ACCESS
CORRIDORS
OTHER
SPACES
ASSEMBLY OCC. BUSINESS OCC. INDUSTRIAL AND STORAGE OCC.
TYPE
SPRINKLERED
THE FACILITY WILL BE PROTECTED BY GENERAL PURPOSE DRY CHEMICAL ABC FIRE EXTINGUISHERS IN ACCORDANCE
WITH NFPA 10 CHAPTER 6 AS REQUIRED BY UFC 3-600-01 SECTION 9-17.2.1.
MINIMUM REQUIREMENTS FOR LIGHT AND ORDINARY HAZARD CLASSIFICATIONS ARE AS FOLLOWS:
LIGHT HAZARD = 2A:10B:C COVERING 6,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 75 FEET.
ORDINARY HAZARD = 2A:10:B:C COVERING 3,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 75 FEET.
EXTRA HAZARD = 4A:80B:C COVERING 4,000 SQ.FT. AND A MAXIMUM TRAVEL DISTANCE OF 50 FEET.
PORTABLE FIRE EXTINGUISHERS WILL BE PROVIDED IN ACCORDANCE WITH NFPA 101 SECTION 9.9.
A WET PIPE SPRINKLER SYSTEM SHALL BE INSTALLED THROUGHOUT THE BUILDING IN ACCORDANCE WITH UFC 3-600-01, UFC 4-211-01 AND AIR FORCE MEMORANDUM FOAM SUNDOWN POLICY. THE BUILDING WILL HAVE AUTOMATIC FIRE SPRINKLER
COVERAGE AS SHOWN ON THE FIRE SUPPRESSION DRAWINGS.
THE SEISMIC DESIGN CATEGORY (SDC) FOR THE CWF BUILDING IS CLASS B.
COMBINATION FIRE ALARM/MASS NOTIFICATION (MNS) THROUGHOUT THE BUILDING – AS SHOWN ON FIRE ALARM DRAWINGS.
BUILDING FIRE ALARM MASS NOTIFICATION CONTROL PANEL (FACU/ACU) WILL BE CONNECTED TO THE BASE REPORTING SYSTEM. TRANSCEIVERS USED FOR CONNECTION TO THE BASE REPORTING SYSTEM SHALL BE COMPATIBLE WITH THE BASE MONACO TRANSCEIVER SYSTEM. IN-BUILDING MNS INTERFACE TO BE STAND ALONE. IN-BUILDING MNS TO BE EQUIPPED WITH
600-OHM AUDIO INPUT TO ALLOW FOR FUTURE WIDE-AREA MNS INTEGRATION.
ELECTRICAL HAZARD CLASSIFICATIONS
THE REQUIREMENTS OF UFC 4-211-01 SECTION 3-7.1 SHALL BE APPLIED. INSIDE THE HANGAR BAY, ALL ELEVATIONS UNDER FINISHED FLOOR SHALL HAVE AN ELECTRICAL CLASS 1, DIV. 1 RATING. THE AREA BETWEEN FINISHED FLOOR AND 18 INCHES ABOVE FINISHED FLOOR IN THE HANGAR BAY, ANY AREA WITHIN 5 FEET OF AIRCRAFT, AND ALL ADJOINING SPACES THAT ARE NOT SUITABLY CUT-OFF PER NFPA 70 SECTION 513.3 (B), SHALL HAVE AN ELECTRICAL HAZARD CLASS 1, DIV. 2 RATING. REFER TO
SHEETS EP109, EP110, EP111, AND EP301 FOR DRAWINGS SHOWING THESE AREAS.
2A:10B:C WEAPONS LOAD STORAGE BAY (132) 2 ORDINARY HAZARD 75 3,000
2A:10B:C WEAPONS RELEASE SHOP (131) 1 ORDINARY HAZARD 75 3,000
2A:10B:C GUN SERVICING/CLEANING (130) 1 ORDINARY HAZARD 75 3,000
2A:10B:C MECH 2 (127) 1 ORDINARY HAZARD 75 3,000
2A:10B:C CORRIDOR 4 (124B) 1 LIGHT HAZARD 75 6,000
2A:10B:C CORRIDOR 2 (124) 1 LIGHT HAZARD 75 6,000
2A:10B:C ELEC (116) 1 ORDINARY HAZARD 75 3,000
2A:10B:C MECH 1 (114) 1 ORDINARY HAZARD 75 3,000
2A:10B:C CORRIDOR 1 (107) 2 LIGHT HAZARD 75 6,000
4A:80B:C CWF HANGAR (101) 3 EXTRA HAZARD 50 4,000
FIRE
EXTINGUISHER
TYPE AND SIZE
ROOM NAME AND NUMBER
NUMBER OF
EXTINGUISHERS
HAZARD
CLASSIFICATION
MAXIMUM
TRAVEL
DISTANCE (FEET)
MAXIMUM AREA
OF COVERAGE
(SF)
STORAGE AND INDUSTRIAL 32 INCHES 34 INCHES 0.2
BUSINESS AND ASSEMBLY 32 INCHES 34 INCHES 0.2
OCCUPANCY REQUIRED CLEAR WIDTH ACTUAL MIN. CLEAR WIDTH FACTOR
STORAGE "S-1" 400 81 100 34 100 0
INDUSTRIAL "F-1" 250 61 100 61 50 0
BUSINESS "B" 300 97 100 41 50 18
ASSEMBLY "A-3" 250 74 20 0 20 0
OCCUPANCY
TYPE
(SPRINKLERED)
TRAVEL
DISTANCE (IN
FEET)
MESURED TRAVEL
DISTANCE (IN FEET)
COMMON
PATH (IN
FEET)
MEASURED
COMMON PATH
(IN FEET)
DEAD END (IN
FEET)
MEASURED DEAD
END (IN FEET)
CWF
SPRINKLER RISER
(FIRE PROTECT ROOM 115)
F
IR
E A
P P
A R
A T
U S
A C
C E
S S
R O
A D
F D
C
F .D
18' - 0"
OUTSIDE COVERED
STORAGE
EXISTING
BUILDINGS
MECHANICAL YARD
ENTRANCE
ENTRANCE
34' - 10"39' - 9"
F F F F F F F
F F
F F
F F
F
F F
F F F F F F
F
F
F
F F
F
DISTANCE TO
CANOPY
FSD
F S
D D
IS
T
A N
C E
T O
B
L D
G
R
R
R
F F
F F
F FF F H
O
S E
P U
L L
F F
F F
F
F
F
F
REFER TO CIVIL
DRAWINGS
REFER TO CIVIL
DRAWINGS
REFER TO CIVIL
DRAWINGS
R
F
F F
F
F
EXTERIOR
COVERED
STORAGE
F
R
F
F
F
F
F
REFER TO CIVIL
DRAWINGS
17' - 11"
FIRE SEPARATION DISTANCE
POST INDICATOR VALVE
FIRE DEPARTMENT ENTRANCE
FIRE DEPARTMENT CONNECTION
FIRE HYDRANT - TWO HOSE OUTLET AND ONE
PUMPER OUTLET
ISOLATION VALVE IN VAULT
FIRE DEPARTMENT ACCESS
FIRE DEPARTMENT ENTRANCE DISTANCE
IMAGINARY LOT LINE
HOSE PULL
DEDICATED UNDERGROUND FIRE WATER MAIN
FDC
F.D.
F
FSD
F F
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL101
CWF
C O
D E
C O
M P
L
IA
N C
E S
IT
E
P L A
N
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
A8
CODE COMPLIANCE SITE PLAN
1" = 30'-0"
SHEET NOTES
LEGEND
PLAN
NORTH
0 30' 60'
1. FIRE HYDRANTS SHALL BE SPACED NO GREATER
THAN 300-FEET APART PER UFC 4-211-01, SECTION
3-6.3.2
2. A MINIMUM OF ONE HYDRANT MUST BE LOCATED NO
GREATER THAN 150-FEET FROM THE FDC PER UFC
3-600-01, SECTION 9-3.5.8.4
3. ALL-WEATHER GROUND ACCESS EMERGENCY
VEHICLE ACCESS SHALL TERMINATE NO GREATER
THAN 33-FEET FROM THE EXTERIOR FIRE
DEPARTMENT ACCESS DOOR PER UFC 3-600-01,
SECTION 9-1.1
4. FIRE APPARATUS ACCESS ROADS SHALL HAVE NOT
LESS THAN 20-FEET UNOBSTRUCTED WIDTH EXCEPT
FOR SECURITY GATES THAT HAVE AN
UNOBSTRUCTED WIDTH OF 13-FEET, 6-INCHES PER
IFC, SECTION 503.2.1
5. RESPONDING FIRE DEPARTMENT HAS EQUIPMENT
APPARATUS MINIMUM TURNING RADIUS OF 39-FEET,
10-INCHES.
6. LOCATE AT LEAST ONE FIRE HYDRANT NO GREATER
THAN 100-FEET OF EACH CORNER OF THE BUILDING
PER UFC 4-211-01, SECTION 3-6.3.2.
7. THE TWO HYDRANTS TO THE SOUTH OF THE
BUILDING ARE EXISTING AND ARE NOT IN THE SCOPE
OF WORK. THEY WILL REMAIN IN SERVICE AND
UNCHANGED. THE FURTHEST CORNER FURTHEREST
FROM A HYDRANT IS 110-FEET AND IS ACCEPTABLE.
WEAPONS LOAD
STORAGE BAY
WEAPONS
RELEASE SHOP
WEAPONS LOAD
SHOP OFFICE
BREAK ROOM
WING WEAPONS
MANAGER
OFFICE
SHARED OFFICE
VEST 2
CLASSROOM
TEST & TRAINING
WEAPONS
ELEMENT SUPR
NCOIC SUPR
MECH 2
COMM
PPE STORAGE
MECH 1
MEN
CWF HANGAR
LOBBY
CORRIDOR 1
CORRIDOR 2
VEST 1
WOMEN
TOOL CRIB
A MKJHGFEDCB
2S S
S S
S S
SSSS
S
S S
S S
S S
S S
S S
S S
S S
O V E R A
LL
S E C
TI
O N D
IA
G
O N A L
7' -6
R E M
O
TE
N
ES
S O
F
EX
IT
S
'-4
R E
M O
T E
N E
S S
O F
E X
IT
S
'-3
N
7.5
5.1
3.1
6.2
2.1
EXTERIOR
COVERED
STORAGE
EXTERIOR
MECHANICAL
YARD
EXTERIOR
COVERED
STORAGE
GUN
SERVICING/CLEANING
OFFICE
SECURITY STOR
OVERALL SECTIO
N D
IAGONAL
120'-9
R E
M O
T E
N E
S S
O F E
X
IT
S
'-0
O V E R
A
LL S
E C
TIO
N D
IA
G
O N A L
111'-7"
JAN CLOSET
STORAGE
FIRE PROTECT
CORRIDOR 3
124A
CORRIDOR 4
124B
ASSEMBLY "A-3" (IBC, SECTION 303.4) /
ASSEMBLY (NFPA 101, SECTION 6.1.2.1)
BUSINESS "B" (IBC, SECTION 304.1) /
BUSINESS (NFPA 101, SECTION 6.1.11.1)
MODERATE HAZARD STORAGE "S-1" (IBC,
SECTION 311.2) / STORAGE (NFPA 101,
SECTION 6.1.13.1)
MODERATE HAZARD FACTORY INDUSTRIAL
GROUP "F-1" (IBC, SECTION 306.2) / (NFPA
101 SECTION 6.1.12.1)
SMOKE PARTITION
1 HR FIRE BARRIER
DRY CHEMICAL ABC EXTINGUISHER
S
B C
A
PLAN
NORTH
8' 16' 32'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W E
S T
W A
L N
U T
S T
R E
E T
(6
-2
P
A S
A D
E N
A C
A L
IF
O
R N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L
E A
IR
N
A T
IO
N
A L
G U
A R
D
FL102
CWF
L
IF
E S
A F
E T
Y F
L O
O R
P L A
N
J A
C K
S O
N V
IL
L
E
F L
O R
ID
A
C
P E
T E
R S
O N
A B
A B
A
IA
N
S G
E O
R G
E
R
M E
D E
IR
O
S
J A
N U
A R
Y
W
S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L
T -F
.R V
T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
SCALE: 1/16" = 1'-0"
A8
LIFE SAFETY FLOOR PLAN - OVERALL
1. FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT
EXCEEDING 40 LB SHALL BE INSTALLED SO THAT THE
TOP OF THE FIRE EXTINGUISHER IS NOT MORE THAN
5 FT. ABOVE FLOOR.
2. FIRE EXTINGUISHERS SHALL BE INSTALLED SO THAT
THE FIRE EXTINGUISHER'S OPERATING
INSTRUCTIONS FACE OUTWARD.
3. CABINETS HOUSING FIRE EXTINGUISHERS SHALL
NOT BE LOCKED.
4. FOR FIRE RESISTANCE-RATED WALLS, ONLY
SURFACE-MOUNTED CABINETS OR LISTED FIRE-
RATED CABINETS SHALL BE INSTALLED.
5. FIRE EXTINGUISHERS SHALL BE INSTALLED IN
LOCATIONS WHERE THEY ARE VISIBLE AND WILL
COORDINATE WITH THE INSTALLATION OF EXIT
SIGNS, EMERGENCY AND EXIT LIGHTING WITH
ELECTRICAL DRAWINGS.
6. PROVIDE 2 FT. RED COLOR STRIPING CLEARANCE
FROM EXTINGUISHERS.
SHEET NOTES
LEGEND
A MKJHGFEDCB
TD=79'-7"
TD=73'-11"
T D
TD=72'-3"
T D
TD=86'-10"
TD=94'-5"TD=96'-6"
C P
TD=73'-2"
48'-0"
N
7.5
5.1
3.1
6.2
2.1
EXTERIOR
COVERED
STORAGE
EXTERIOR
MECHANICAL
YARD
EXTERIOR
COVERED
STORAGE
WEAPONS LOAD
STORAGE BAY
WEAPONS
RELEASE SHOP
WEAPONS LOAD
SHOP OFFICE
BREAK ROOM
WING WEAPONS
MANAGER
OFFICE
SHARED OFFICE
VEST 2
CLASSROOM
TEST & TRAINING
WEAPONS
ELEMENT SUPR
NCOIC SUPR
MECH 2
COMM
PPE STORAGE
MECH 1
MEN
CWF HANGAR
LOBBY
CORRIDOR 1
CORRIDOR 2
VEST 1
WOMEN
TOOL CRIB
GUN
SERVICING/CLEANING
OFFICE
SECURITY STOR
DE=17'-8"
M A
T C
H L
IN
E
/A
F L
M A
T C
H L
IN
E
/A
F L
M A
T C
H L
IN
E
/A
F L
M A
T C
H L
IN
E
/A
F L
JAN CLOSET
STORAGE
FIRE PROTECT
CORRIDOR 3
124A
CORRIDOR 4
124B
ILLUMINATED SINGLE SIDED EXIT SIGN
ILLUMINATED DOUBLE SIDED EXIT SIGN
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END
EXIT ID
CLEAR WIDTH DOOR/STAIR (INCHES)
EGRESS CAPACITY FACTOR DOOR/STAIR
AVAILABLE EXIT CAPACITY (PERSONS)
ASSIGNED EXIT CAPACITY
TD
CP
DE
X
XX XX
0.2 0.3
B C
A
PLAN
NORTH
8' 16' 32'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL103
CWF
L
IF
E S
A F
E T
Y E
G R
E S
S F
L O
O R
P L A
N
O V
E R
A L L
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
SCALE: 1/16" = 1'-0"
A8
LIFE SAFETY EGRESS FLOOR PLAN - OVERALL
1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE
LOCATED AT VERTICAL DISTANCE OF NOT MORE
THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE
EGRESS OPENING INTENDED FOR DESIGNATION BY
THAT MARKING.
2. EGRESS MARKING SHALL BE LOCATED AT A
HORIZONTAL DISTANCE OF NOT MORE THAN THE
REQUIRED WIDTH OF THE EGRESS OPENING, AS
MEASURED FROM THE EDGE OF THE EGRESS
OPENING INTENDED FOR DESIGNATION BY THAT
MARKING TO THE NEAREST EDGE OF THE MARKING.
ILLUMINATED SINGLE SIDED EXIT SIGN
ILLUMINATED DOUBLE SIDED EXIT SIGN
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END
EXIT ID
CLEAR WIDTH DOOR/STAIR (INCHES)
EGRESS CAPACITY FACTOR DOOR/STAIR
AVAILABLE EXIT CAPACITY (PERSONS)
ASSIGNED EXIT CAPACITY
TD
CP
DE
X
XX XX
0.2 0.3
A EDCB
5.1
3.1
6.2
7.4
2.1
CWF HANGAR
B
34 NA
0.2 0.3
A
34 NA
0.2 0.3
C
34 NA
0.2 0.3
M A
T C
H L
IN
E
/A
F L
48'-0"
B C
A
PLAN
NORTH
4' 8' 16'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL104
CWF
L
IF
E S
A F
E T
Y E
G R
E S
S F
L O
O R
P L A
N
A R
E A
A
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE
LOCATED AT VERTICAL DISTANCE OF NOT MORE
THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE
EGRESS OPENING INTENDED FOR DESIGNATION BY
THAT MARKING.
2. EGRESS MARKING SHALL BE LOCATED AT A
HORIZONTAL DISTANCE OF NOT MORE THAN THE
REQUIRED WIDTH OF THE EGRESS OPENING, AS
MEASURED FROM THE EDGE OF THE EGRESS
OPENING INTENDED FOR DESIGNATION BY THAT
MARKING TO THE NEAREST EDGE OF THE MARKING.
SHEET NOTES
LEGEND
SCALE: 1/8" = 1'-0"
A8
LIFE SAFETY EGRESS FLOOR PLAN - AREA A
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END
EXIT ID
CLEAR WIDTH DOOR/STAIR (INCHES)
EGRESS CAPACITY FACTOR DOOR/STAIR
AVAILABLE EXIT CAPACITY (PERSONS)
ASSIGNED EXIT CAPACITY
TD
CP
DE
X
XX XX
0.2 0.3
JHGFED
GUN
SERVICING/CLEANING
WEAPONS LOAD
SHOP OFFICE
BREAK ROOM
WING WEAPONS
MANAGER
OFFICE
SHARED OFFICE
CLASSROOM
TEST & TRAINING
WEAPONS
ELEMENT SUPR
NCOIC SUPR
MECH 2
COMM
PPE STORAGE
ELEC
JAN CLOSET
STORAGE
FIRE PROTECT
MECH 1
LOBBY
CORRIDOR 1
CORRIDOR 2
VEST 1
SECURITY STOR
WOMEN
TOOL CRIB
M A
T C
H L
IN
E
/A
F L
M A
T C
H L
IN
E
/A
F L
EXTERIOR
COVERED
STORAGE
EXTERIOR
MECHANICAL
YARD
OFFICE
MEN
D
68 NA
0.2 0.3
E
34 NA
0.2 0.3
F
34 NA
0.2 0.3
G
34 NA
0.2 0.3
H
34 NA
0.2 0.3
I
68 NA
0.2 0.3
J
34 NA
0.2 0.3
K
34 NA
0.2 0.3
P
68 NA
0.2 0.3
T D
T D
TD=86'-10"
TD=94'-5"TD=96'-6"
C P
TD=73'-2"
EXTERIOR
COVERED
STORAGE
EXTERIOR
MECHANICAL
YARD
DE=17'-8"
VEST 2
CORRIDOR 4
124B
CORRIDOR 3
124A
B C
A
PLAN
NORTH
4' 8' 16'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL105
CWF
L
IF
E S
A F
E T
Y E
G R
E S
S F
L O
O R
P L A
N
A R
E A
B
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE
LOCATED AT VERTICAL DISTANCE OF NOT MORE
THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE
EGRESS OPENING INTENDED FOR DESIGNATION BY
THAT MARKING.
2. EGRESS MARKING SHALL BE LOCATED AT A
HORIZONTAL DISTANCE OF NOT MORE THAN THE
REQUIRED WIDTH OF THE EGRESS OPENING, AS
MEASURED FROM THE EDGE OF THE EGRESS
OPENING INTENDED FOR DESIGNATION BY THAT
MARKING TO THE NEAREST EDGE OF THE MARKING.
SHEET NOTES
LEGEND
SCALE: 1/8" = 1'-0"
LIFE SAFETY EGRESS FLOOR PLAN - AREA B
TRAVEL DISTANCE
COMMON PATH OF TRAVEL
DEAD END
EXIT ID
CLEAR WIDTH DOOR/STAIR (INCHES)
EGRESS CAPACITY FACTOR DOOR/STAIR
AVAILABLE EXIT CAPACITY (PERSONS)
ASSIGNED EXIT CAPACITY
TD
CP
DE
X
XX XX
0.2 0.3
MKJ
N
WEAPONS LOAD
STORAGE BAY
WEAPONS
RELEASE SHOP
M A
T C
H L
IN
E
/A
F L
M
34 NA
0.2 0.3
L
34 NA
0.2 0.3
N
34 NA
0.2 0.3
TD=79'-7"
TD=73'-11"
T
D
TD=72'-3"
B C
A
PLAN
NORTH
4' 8' 16'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FL106
CWF
L
IF
E S
A F
E T
Y E
G R
E S
S F
L O
O R
P L A
N
A R
E A
C
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
1. THE BOTTOM OF EXIT MARKING/SIGNS SHALL BE
LOCATED AT VERTICAL DISTANCE OF NOT MORE
THAN 6 FT. 8 INCHES ABOVE THE TOP EDGE OF THE
EGRESS OPENING INTENDED FOR DESIGNATION BY
THAT MARKING.
2. EGRESS MARKING SHALL BE LOCATED AT A
HORIZONTAL DISTANCE OF NOT MORE THAN THE
REQUIRED WIDTH OF THE EGRESS OPENING, AS
MEASURED FROM THE EDGE OF THE EGRESS
OPENING INTENDED FOR DESIGNATION BY THAT
MARKING TO THE NEAREST EDGE OF THE MARKING.
SHEET NOTES
LEGEND
SCALE: 1/8" = 1'-0"
LIFE SAFETY EGRESS FLOOR PLAN - AREA C
1. THE BUILDING WILL BE PROTECTED BY AUTOMATIC FIRE SPRINKLER SYSTEMS. THE SPRINKLER SYSTEM DESIGN AND INSTALLATION MUST BE IN STRICT ACCORDANCE WITH THE MOST CURRENT EDITIONS OF NFPA 13, UFC 3-600-01, UFC
4-211-01 AND SPECIFICATION 21 13 13.
2. THE SPRINKLER SYSTEMS MUST BE HYDRAULICALLY CALCULATED IN ACCORDANCE WITH NFPA 13, UFC 3-600-01, UFC
4-211-01 AND SPECIFICATION 21 13 13.
3. SPRINKLER HEADS MUST BE BRASS UPRIGHTS WHERE NO FINISHED CEILING IS PROVIDED EXCEPT AS NOTED. WHERE A LAY IN CEILING IS PROVIDED, SPRINKLER HEADS MUST BE PENDENTS WITH A CHROME FINISH. THE USE OF EXTENDED COVERAGE SPRINKLERS IS PROHIBITED PER UFC 3-600-01 SECTION 9-7.4.3 EXCEPT AS NOTED. ALL SPRINKLERS ON THE GRID CEILING SHALL BE PLACED AT THE CENTER OF THE CEILING PANEL.
4. PROVIDE VALVE SUPERVISORY TAMPER DEVICES ON FIRE PROTECTION CONTROL VALVES FOR MONITORING BY THE
FIRE ALARM/MASS NOTIFICATION CONTROL PANEL.
5. SPRINKLER SYSTEM PIPING MUST BE BLACK STEEL PIPE WITH FURNACE BUTT-WELDS (ASTM A53, TYPE F). PIPING 2 IN.
AND LESS MUST BE MINIMUM SCHEDULE 40. PIPING LARGER THAN 2 IN. MUST BE MINIMUM SCHEDULE 10 IN.
ACCORDANCE WITH UFC 3-600-01 SECTION 9-7.6.2.
6. WET SPRINKLER PIPING IS PERMITTED TO BE INSTALLED LEVEL. AUXILIARY DRAINS MUST BE PROVIDED WHERE A CHANGE IN PIPING DIRECTION PREVENTS DRAINAGE OF SYSTEM PIPING THROUGH THE MAIN DRAIN OR THROUGH A SINGLE SPRINKLER HEAD WHERE LESS THAN 5 GALLONS OF WATER IS TRAPPED BY THE SINGLE SPRINKLER.
7. LOCATE THE SPRINKLER RISER INSPECTOR’S TEST CONNECTION AT THE RISER.
8. MARK EXPOSED INTERIOR PIPING WITH PLASTIC WRAP-AROUND TYPE PIPE LABELS CONFORMING TO AMERICAN SOCIETY OF MECHANICAL ENGINEERS/AMERICAN NATIONAL STANDARDS INSTITUTE (ASME/ANSI) A13.1. INDICATE THE TYPE OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS IN THE MECHANICAL ROOM MUST BE VISIBLE FROM AT LEAST THREE SIDES WHEN VIEWED FROM THE FLOOR. LABELS THAT STICK-ON (ADHESIVE BACKED) OR ARE HELD ON WITH STRAPS/ADHESIVE TAPE ARE NOT PERMITTED. LABELS ARE NOT REQUIRED ON FIRE SUPPRESSION SYSTEM BRANCH LINES REGARDLESS OF SIZE, OR MAINS AND CROSS-MAINS LESS THAN A NOMINAL 2-1/2 INCHES. LABELS ARE NOT REQUIRED ON PIPING ROUTED BELOW THE FLOOR LINE IN TRENCHES OR PITS. AT A MINIMUM, THE FOLLOWING LABELS ARE REQUIRED: "FIRE PROTECTION WATER" -USED ON DEDICATED POTABLE AND NON-PORTABLE FIRE PROTECTION WATER SUPPLY PIPING. "FIRE SPRINKLER" - USED ON WATER-ONLY SPRINKLER PIPING. "FIRE DEPT.
CONNECTION" - USED ON THE FDC PIPING.
9. FIRE SUPPRESSION SYSTEM VALVES MUST BE MARKED WITH PERMANENT TAGS INDICATING NORMALLY OPEN OR
NORMALLY CLOSED.
10. ROUTE CLEAR WATER DRAINS TO THE BUILDING EXTERIOR AND DISCHARGE NO GREATER THAN 2 FT. ABOVE GRADE.
PROVIDE INDEPENDENT ATMOSPHERIC AND PRESSURIZED DRAINAGE SYSTEMS, OR PROVIDE A MEANS OF HYDRAULIC ISOLATION BETWEEN THE SYSTEMS SUCH AS A CHECK VALVE BETWEEN THE CUP DRAIN AND THE MAIN DRAIN.
PROVIDE A SPLASH BLOCK BELOW DRAIN DISCHARGE, UNLESS DISCHARGING TO A PAVED OR CONCRETE SURFACE.
DO NOT LOCATE DRAINAGE DISCHARGE ADJACENT TO AN EXIT DOOR, NOR PERMIT DRAINAGE DISCHARGE TO CROSS THE PATH OF EGRESS FROM THE BUILDING. LOCATE DRAINAGE DISCHARGE TO NOT CAUSE SOIL EROSION WHEN MAIN
DRAIN OR INSPECTOR’S TEST CONNECTIONS ARE OPERATED DURING TESTING.
11. ALL PIPING IDENTIFICATION SHALL COMPLY WITH UFC 3-600-01.
12. THE FIRE SUPPRESSION SYSTEMS SHALL USE A DEDICATED NON-POTABLE WATER SUPPLY. THE DESIGN AND
INSTALLATION IS NOT REQUIRED TO INCLUDE A BACKFLOW PREVENTER.
13. WATER SUPPLY ENTRANCE TO BUILDING SHALL BE A CONTINUOUS SECTION OF WELDED STAINLESS STEEL TO A FLANGED FITTING A MINIMUM OF 12 INCHES A.F.F. WITHIN THE FIRE PROTECTION ROOM IN ACCORDANCE WITH UFC
4-211-01 SECTION 3-6.4.2.3.
14. TESTING OF THE AUTOMATIC SPRINKLER SYSTEM SHALL BE COMPLETED BY A QUALIFIED REPRESENTATIVE. TESTING SHALL BE IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.20. TESTING PROCEDURES SHALL BE WRITTEN PRIOR TO FINAL ACCEPTANCE AND BE REVIEWED BY THE EOR. FINAL ACCEPTANCE TESTING SHALL BE WITNESSED BY AHJ AND
EOR.
15. COORDINATE WITH MECHANICAL CONTRACTOR TO ENSURE THAT IF ANY OBSTRUCTIONS ARE INSTALLED, CODE
COMPLIANT COVERAGE IS PROVIDED.
16. THE CONTRACTOR MUST COORDINATE THE FIRE SUPPRESSION SYSTEM WITH THE STEEL JOIST FABRICATOR, AND THE STEEL JOIST FABRICATOR MUST SUBMIT A CERTIFIED LETTER TO THE ARCHITECT AND COPIED TO THE STRUCTURAL ENGINEER OF RECORD STATING THAT HE HAS RECEIVED SPRINKLER DRAWINGS WHERE APPLICABLE. THE STEEL JOIST FABRICATOR MUST DESIGN THE STEEL JOISTS FOR ADDITIONAL LOADING IMPOSED BY SPRINKLER MAIN SUPPLY
LINE AND BRANCHES WHERE APPLICABLE.
1. IBC 2024, AS REFERENCED AND AMENDED BY UFC 1-200-01
2. NFPA 1, NATIONAL FIRE CODE, 2024
3. NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2022
4. NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS AND THEIR
APPURTENANCES, 2022
5. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021
6. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY
DAF FOAM SUNDOWN POLICY
7. MIL-STD-101C, COLOR CODE FOR PIPELINES, AUGUST 26, 2014
WET SPRINKLER RISER
OS&Y VALVE WITH TAMPER SWITCH
CHECK VALVE
TEST HEADER
FIRE DEPARTMENT CONNECTION
FLOW SWITCH
RESTRICTING ORIFICE
PRESSURE RELIEF VALVE
PRESSURE GAUGE
ALARM CHECK VALVE
CONTROL VALVE
WF
A
REMARKS: MINIMUM SPRINKLER OPERATION AREA AND K-FACTOR PER UFC 3-600-01 TABLE 9-3 AND UFC 4-211-01 SECTION 3-6.15.1.
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FX001
CWF
F
IR
E S
U P
P R
E S
S
IO
N G
E N
E R
A L N
O T
E S
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
FIRE SUPPRESSION LEGEND ABBREVIATIONS APPLICABLE CODES AND STANDARDS GENERAL FIRE SUPPRESSION NOTES
UNO UNLESS NOTED OTHERWISE
UL UNDERWRITERS LABORATORIES
UFC UNIFIED FACILITIES CRITERIA
SQ. FT. SQUARE FEET
PSI POUNDS PER SQUARE INCH
PIV POST INDICATOR VALVE
OS&Y OUTSIDE STEM AND YOKE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NO NORMALLY OPEN
NC NORMALLY CLOSED
GPM GALLONS PER MINUTE
FP FIRE PROTECTION
FM FACTORY MUTUAL
FDC FIRE DEPARTMENT CONNECTION
EOR ENGINEER OF RECORD
BLDG BUILDING
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AHJ AUTHORITY HAVING JURISDICTION
AFF ABOVE FINISHED FLOOR
HAZARD CLASSIFICATION TABLE
HANGAR 0.20 5.6 OR 8.0 5000 500 45 130 200 WET 37'-0"
ORDINARY 0.20 8.0 2500 250 60 130 200 WET VARIES
LIGHT 0.10 5.6 1500 250 60 225 155 WET 10'-0"
HAZARD
DENSITY
(GPM/SQ.FT.)
K-FACTOR
DESIGN AREA
(SQ.FT.)
HOSE
GAL/MIN.
DURATION OF
SUPPLY MIN.
MAX. AREA
PER HEAD
(SQ.FT.)
TEMP. RATING SYSTEM TYPE
MAX. CEILING
HEIGHT
WEAPONS
RELEASE SHOP
WEAPONS LOAD
SHOP OFFICE
BREAK ROOM
WING WEAPONS
MANAGER
OFFICE
SHARED OFFICE
VEST 2
CLASSROOM
TEST & TRAINING
WEAPONS
ELEMENT SUPR
NCOIC SUPR
MECH 2
COMM
PPE STORAGE
ELEC
JAN CLOSET
STORAGE
111FIRE PROTECT
MECH 1
MEN
CWF HANGAR
LOBBY
CORRIDOR 1
CORRIDOR 2
VEST 1
WOMEN
TOOL CRIB
A MKJHGFEDCB
A12
FX401
N
7.5
5.1
3.1
6.2
2.1
EXTERIOR
COVERED
STORAGE
EXTERIOR
MECHANICAL
YARD
EXTERIOR
COVERED
STORAGE
GUN
SERVICING/CLEANING
OFFICE
CORRIDOR 4
124B
CORRIDOR 3
124A
LIGHT HAZARD: 0.10 GPM OVER 1500 SQ. FT.
K-FACTOR MINIMUM = 5.6
ORDINARY HAZARD: 0.20 GPM OVER 2500 SQ. FT.
K-FACTOR MINIMUM = 8.0
HANGAR 0.20 OVER 5000 SQ. FT.
K-FACTOR MINIMUM = 5.6 OR 8.0
WET SPRINKLER RISER
OS&Y VALVE WITH TAMPER SWITCH
CHECK VALVE
TEST HEADER
FIRE DEPARTMENT CONNECTION
FLOW SWITCH
RESTRICTING ORIFICE
PRESSURE RELIEF VALVE
PRESSURE GAUGE
ALARM CHECK VALVE
CONTROL VALVE
WF
A
B C
A
PLAN
NORTH
8' 16' 32'0'
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
GRAPHIC SCALE
KEY PLAN
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FX101
CWF
F
IR
E S
U P
P R
E S
S
IO
N H
A Z
A R
D C
L A
S S
IF
IC
A T
IO
N
F L O
O R
P L A
N
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
SCALE: 1/16" = 1'-0"
A8
FIRE SUPPRESSION HAZARD CLASSIFICATION FLOOR PLAN - OVERALL
1. REFER TO SHEET FX001 FOR GENERAL NOTES,
APPLICABLE CODES, ABBREVIATIONS, AND SYMBOLS.
2. MINIMUM SPRINKLER OPERATION AREA AND K-
FACTOR ON SHEET LEGEND PER UFC 3-600-01 TABLE
9-3.
SHEET NOTES
LEGEND
KEY NOTES
USE LISTED AND APPROVED EXTENDED
COVERAGE DRY SIDEWALL SPRINKLER HEADS
F
FIRE PROTECT
A12
FX401
' - 0
MAIN DRAIN TO EXTERIOR
8" SUPPLY MAIN
FINISH FLOOR
0'-0"
BY DIVISION 21BY DIVISION 33
PROVIDE SLEEVE FOR SUPPLY MAIN AT
PENETRATION THROUGH CONCRETE
SLAB PER NFPA 13, SECTION 18.4.3
PROVIDE 8" SUPPLY MAIN
(ONE PIECE STAINLESS STEEL PIPE)
SEE CIVIL DRAWINGS
FOR CONTINUATION
BUTTERFLY VALVE
W/TAMPER
RISER CHECK VALVE
WATER FLOW SWITCH
CONCENTRIC REDUCER
CHECK VALVE
F R
O M
R E
M O
T E
F D
C
T O
C W
F H
A N
G A
R
T O
B U
IL
D
IN
G
CHECK VALVE
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FX401
CWF
F
IR
E S
U P
P R
E S
S
IO
N E
N L A
R G
E D
P L A
N S
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
SCALE: 1/4" = 1'-0"
H12
SPRINKLER RISER ENLARGED PLAN
SCALE: NTS
H7
3D SPRINKLER RISER DETAIL
SCALE: 1/4" = 1'-0"
A12
SPRINKLER RISER SECTION
1. PROVIDE AN ADDRESSABLE COMBINATION FIRE ALARM AND MASS NOTIFICATION SYSTEM IN
ACCORDANCE WITH THE CURRENT EDITIONS OF UFC 3-600-01, UFC 4-021-01, UFC 4-211-01, NFPA 72, ECB 2018-17, AND SPECIFICATION 28 31 76.
2. INSTALLING CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS THAT MAY AFFECT THE SYSTEM
INSTALLATION OR COMPLIANCE WITH THE APPLICABLE CODES AND MUST NOTIFY THE
CONTRACTING OFFICER PRIOR TO BEGINNING WORK.
3. THE LOCATION OF DEVICES SHOWN IS SUGGESTED. ACTUAL LOCATIONS TO BE DETERMINED BY
INSTALLING CONTRACTOR IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED HEREIN.
4. RF TRANSCEIVER OPERATION REQUIRES AUTHORIZATION FROM THE BASE INSTALLATION
MANAGER.
5. FIRE ALARM CONTROL UNITS MUST NOT BE USED AS A RACEWAY FOR ROUTING CONDUCTORS
WHICH WILL NOT BE TERMINATED IN THAT CONTROL UNIT. PROVIDE 1/4 INCH SEPARATION
BETWEEN POWER-LIMITED AND NON-POWER LIMITED CIRCUITS. CONDUCTOR INSTALLED SHALL BE IN COMPLIANCE WITH NFPA 70, 760.48, AND NFPA 70, 760.136(D) WHERE POWER LIMITED AND NON-
POWER LIMITED WIRING ENTER THE SAME ENCLOSURE.
6. BACKUP BATTERY CAPACITY SHALL BE FOR 48 HOURS STANDBY AND 15 MINUTES OF ALARM.
7. WIRING MUST BE MINIMUM CLASS "B" AND INSTALLED IN METALLIC CONDUITS NO LESS THAN 3/4"
AND NOT EXCEED FILL RATES AS OUTLINED IN NFPA 70.
8. CONDUCTOR SIZING NOT LESS THAN 18 AWG FOR SLC, 16 AWG FOR AUDIO, AND 14 AWG FOR NAC.
CONSISTENTLY COLOR COORDINATE CONDUCTORS THROUGH THE SYSTEM IN RELATION TO
DEVICES THEY FEED (E.G. SLC -BLACK/RED,STROBE - YELLOW/BLUE).
9. RUN CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. THE USE OF WIRE NUTS, CRIMPED
CONNECTORS, OR TWISTING CONDUCTORS ARE PROHIBITED. UTILIZE TERMINAL STRIPS WHERE
CONDUCTORS CANNOT BE DIRECTLY TERMINATED AT THE DEVICE. ALL DEVICES MUST HAVE
SCREW TERMINALS WHERE DEVICES ARE ONLY PROVIDED WITH PIGTAILS FROM THE
MANUFACTURER, PIGTAILS MUST BE LANDED ON TERMINAL STRIPS MOUNTED WITHIN THE
JUNCTION BOX.
10. FIRE ALARM CONDUITS, JUNCTION BOXES, ASSOCIATED WIRING, AND ACCESSORIES MUST NOT BE
INSTALLED AT OR BELOW 24 INCH A.F.F UNLESS SPECIFICALLY DIRECTED BY CODE OR
MANUFACTURER.
11. MANUAL PULL STATIONS MUST BE PROVIDED AT ALL EXITS. LOCATIONS MUST BE WITHIN 5 FT OF
THE EXIT DOOR.
12. PROVIDE ADDRESSABLE DOUBLE-ACTION TYPE MANUAL PULL STATIONS WITH KEY RESET. KEY
MUST BE SAME AS FACU/ACU CABINET.
13. SMOKE DETECTORS LISTED FOR USE IN AIR DISTRIBUTION SYSTEMS SHALL BE LOCATED
DOWNSTREAM OF THE AIR FILTERS AND AHEAD OF ANY BRANCH CONNECTIONS IN AIR SUPPLY
SYSTEMS HAVING A CAPACITY GREATER THAN 2000 CFM/MIN. (NFPA 90A 2024 SECTION11.4.2.1).
14. FIRE ALARM/MASS NOTIFICATION STROBES AND/OR SPEAKER/STROBES MUST HAVE A CLEAR LENS
AND BE MARKED "ALERT."
15. CONNECT BUILDING FACU/ACU TO EXISTING BASE MONACO D-21 REPORTING SYSTEM. PROVIDE
COMPATIBLE TRANSCEIVER FOR CONNECTION TO BASE REPORTING SYSTEM.
16. SPEAKERS IN THE VICINITY OF THE FACU/ACU AND LOC SHALL NOT CREATE ACOUSTICAL
FEEDBACK OR INTERFERE WITH THE ABILITY TO DELIVER LIVE VOICE MESSAGES.
17. MEET THE FOLLOWING INTELLIGIBILITY CRITERIA:
A. ACHIEVE A CIS SCORE OF 0.80 IN ALL AREA OF EACH ROOM MEASURED AT 5 FT AFF.
B. A LESSER CIS IS PERMITTED IN AREAS OF THE BUILDING WITH EXCESSIVE SOUND REFLECTIONS, SUCH AS ROOMS WITH HARD SURFACES (METAL, TILE, OR CONCRETE), WHERE THE OCCUPANT
CAN WALK NO MORE THAN 33 FT TO A LOCATION IN THE SAME ROOM THAT ACHIEVES THE MINIMUM
CIS (0.8).
C. A LESSER CIS IS PERMITTED IN NORMALLY UNOCCUPIED ROOMS OF THE BUILDING, WHERE THE OCCUPANT CAN WALK NO MORE THAN 50 FT TO A LOCATION IN THE SAME ROOM THAT ACHIEVES
THE MINIMUM CIS (0.8). NORMALLY UNOCCUPIED ROOMS ARE CONSIDERED TO BE STORAGE
ROOMS, MECHANICAL / ELECTRICAL ROOMS, COMMUNICATION CLOSETS, AND FIRE PROTECTION
ROOMS.
D. THE HANGAR BAY SHALL BE MODELED DURING DESIGN FOR ACOUSTICAL INTELLIGIBILITY. ALL AREAS WITHIN THE ROOM (BAY) IN THE MODEL AND AT TESTING SHALL BE WITHIN 50FT OF AN AREA
WITH A 0.7 (0.65 ROUNDED) CIS.
18. ACTIONS TAKEN AT THE FACU/ACU TAKE PRECEDENCE OVER ACTIONS TAKEN ELSEWHERE.
19. MINIMUM STROBE CANDELA SHOWN FOR REFERENCE ONLY. ACTUAL CANDELA MUST BE
DETERMINED BY INSTALLING CONTRACTOR BASED ON LAYOUT. ENSURE STROBES IN THE SAME
FIELD OF VIEW FLASH IN SYNCHRONIZATION.
20. VISIBLE NOTIFICATION IS REQUIRED IN ALL NORMALLY OCCUPIED, PUBLIC AND COMMON USE
AREAS (BREAK ROOMS, REST ROOMS, CORRIDORS, CONFERENCE ROOMS, OFFICES GREATER
THAN 2 OCCUPANTS).
21. VISIBLE NOTIFICATION IS REQUIRED IN ALL NORMALLY UNOCCUPIED AREAS GREATER THAN 900 SQ.
FT. OR IF HEARING PROTECTION IS REQUIRED.
22. PROVIDE VISUAL NOTIFICATION FOR BATHROOMS SERVING GREATER THAN SINGLE PERSON
OFFICES PER UFC 3-600-01 SECTION 9-18.6.3(K).
23. ANY ALARM STATUS MUST SHUTDOWN HVLS FANS PER UFC 3-600-01, SECTION 7-6.
24. REFER TO ARCHITECTURAL DRAWINGS FOR INFORMATION ON ROOM DIMENSIONS, CEILING
HEIGHTS, AND OTHER PHYSICAL MEASUREMENTS.
25. TESTING OF THE FACU/ACU SYSTEMS SHALL BE COMPLETED BY AN AUTHORIZED FACTORY
REPRESENTATIVE. TESTING SHALL BE PERFORMED IN ACCORDANCE WITH UFC 4-211-01 SECTION
3-6.20. TESTING PROCEDURES SHALL BE WRITTEN PRIOR TO FINAL ACCEPTANCE AND BE
REVIEWED BY THE EOR. FINAL ACCEPTANCE TESTING SHALL BE WITNESSED BY AHJ AND THE EOR.
26. FLEXIBLE CONDUIT IS PERMITTED ONLY WHEN TERMINATING AT FIRE SUPPRESSION EQUIPMENT OR IN DEVICES MOUNTED IN MOVABLE CEILING TILES. THE LENGTH OF FLEXIBLE CONDUIT IS LIMITED TO A MAXIMUM CONDUIT LENGTH OF 6 FT. IN ACCORDANCE WITH UFC 4-211-01 SECTION 3-6.19.5.
27. CONDUIT ENTRY INTO THE TOP OF ANY CONTROL PANEL IS PROHIBITED.
28. ALL DEVICES MOUNTED INSIDE HANGAR BAY SHALL HAVE A MINIMUM NEMA 4 RATING.
29. ALL DISCONNECTS OF PRIMARY POWER CIRCUITS FOR THE FIRE ALARM SYSTEM SHALL COMPLY WITH NFPA 72, CHAPTER 10.6.5.2, AND BE MARKED IN RED AND NOT OBSCURE MANUFACTURER
MARKINGS.
30. REFERENCE SHEETS EP109, EP110, EP111, AND EP301 FOR LOCATIONS OF ELECTRICAL HAZARD CLASSIFIED AREAS. COMPONENTS AND SUPPORTING INSTALLATION INSTALLED WITHIN ELECTRICAL
HAZARD CLASSIFIED AREAS MUST COMPLY WITH REQUIREMENTS OF NEC.
1. IBC 2021, AS REFERENCED AND AMENDED BY UFC 1-200-01, CHANGE 2
2. NFPA 70, NATIONAL ELECTRICAL CODE (NEC), 2023
3. NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE, 2022
4. UFC 3-520-01, INTERIOR ELECTRICAL SYSTEMS, CHANGE 2, APRIL 12, 2021
5. UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES, CHANGE 6, MAY 6, 2021
6. UFC 4-010-01, DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS, CHANGE 2, JULY 30, 2022
7. UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS, CHANGE 1, JANUARY 1, 2010
8. UFC 4-211-01, AIRCRAFT MAINTENANCE HANGARS, CHANGE 3, APRIL 20, 2021 AS AMENDED BY
DAF FOAM SUNDOWN POLICY
9. ECB 2018-17, NEW REQUIREMENTS FOR VISUAL NOTIFICATION FOR MASS NOTIFICATION
SYSTEMS, OCTOBER 25, 2018
10. ANG ETL 15-01-03, FIRE PROTECTION DESIGN GUIDANCE, MAY 1, 2015
FACU/ACU FIRE ALARM CONTROL UNIT
LOCAL OPERATOR CONSOLE
PHOTOELECTRIC SMOKE DETECTOR
DUCT SMOKE DETECTOR
MANUAL PULL STATION
ADDRESSABLE INPUT MODULE
ADDRESSABLE OUTPUT MODULE
SPEAKER/STROBE, CEILING MOUNT
SPEAKER ONLY
STROBE ONLY, CEILING MOUNT
STROBE ONLY, WALL MOUNT
HORN/STROBE, OUTDOOR RATED
SURGE PROTECTION DEVICE
ANTENNA
DOCUMENT STORAGE BOX
WATER FLOW SWITCH
VALVE SUPERVISORY SWITCH
END-OF-LINE RESISTOR
RELAY
LOW TEMPERATURE DETECTOR
EMERGENCY EYE-WASH STATION
BUILDING KEY LOCK BOX
CM
CD
WP
SPD
LOC
DOC
S
F
AOM
AIM
S
S
M
WF
VS
EOL
RL
LT
M
EEWS
LBX
SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:
DRAWING SEQUENCE NUMBER INDICATES
WHERE TITLE IS LOCATED (MAY NOT BE
PRESENT IF CALLOUT AND TITLE ARE ON THE
SAME DRAWING)
LETTER AND NUMBER INDICATE
SHEET GRID COORDINATE OF VIEW
ONE OR TWO CHARACTER DISCIPLINE
DESIGNATOR (MAY NOT BE PRESENT IF
CALLOUT AND TITLE ARE ON DRAWINGS
WITHIN THE SAME DISCIPLINE)
LETTER AND NUMBER INDICATE
SHEET GRID COORDINATE OF VIEW
WALL SECTION CALLOUT EXAMPLE:
DETAIL CALLOUT EXAMPLE:
ELEVATION CALLOUT EXAMPLE:
SECTION, DETAIL, AND ELEVATION TITLE EXAMPLE:
EXTERIORINTERIOR
NORTH ARROW EXAMPLE:
LETTER AND NUMBER
INDICATE SHEET GRID
COORDINATE OF VIEW
SHEET NUMBER WHERE
SECTION IS DRAWN
LETTER AND NUMBER
INDICATE SHEET GRID
COORDINATE OF VIEW
SHEET NUMBER WHERE
SECTION IS DRAWN
BUILDING SECTION CALLOUT EXAMPLE:
VIEW REFERENCE EXAMPLE:
LETTER AND NUMBER INDICATE
SHEET GRID COORDINATE OF VIEW
SHEET NUMBER WHERE
SECTION IS DRAWN
LETTER AND NUMBER
INDICATE SHEET GRID
COORDINATE OF VIEW
SHEET NUMBER WHERE
DETAIL IS DRAWN
A1
A401
A1
A311
A1
A311
A1
A301
A1
A301
A1
A401
A1
A201
A751
A1
A3
A4A2
VIEW TITLE
A1
VIEW TITLE
VIEW SCALE
VIEW SCALE BAR
SCALE: 1/8" = 1'-0" 0 4' 8' 16'
PLAN
NORTH
PLAN NORTH
TRUE NORTH
NORTH ARROW INDICATING PLAN
NORTH AND TRUE NORTH
A1
A311
P A
R S
O N
S G
O V
E R
N M
E N
T S
E R
V
IC
E S
I N
C
W
E S
T W
A L N
U T
S T
R E
E T
(6
-2
P A
S A
D E
N A
C A
L
IF
O R
N
IA
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D x
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T A
S K
O R
D E
R N
O
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N F
IL
E
N A
M E
1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20
N
L
J
G
E
C
A
P
M
K
H
F
D
B
THIS ITEM HAS BEEN DIGITALLY SIGNED AND
SEALED BY ON THE
DATE ADJACENT TO THE SEAL.
PRINTED COPIES OF THIS DOCUMENT ARE
NOT CONSIDERED SIGNED AND SEALED AND
THE SIGNATURE MUST BE VERIFIED ON ANY
ELECTRONIC COPIES.
J A
C K
S O
N V
IL
L E
A
IR
N A
T
IO
N A
L G
U A
R D
FA001
CWF
F
IR
E A
L A
R M
G E
N E
R A
L N
O T
E S
J A
C K
S O
N V
IL
L E
F
L O
R
ID
A C
P
E T
E R
S O
N
A B
A B
A
IA
N
S G
E O
R G
E
R M
E D
E
IR
O S
J A
N U
A R
Y
W S
Y
F
F A
-2
-D
-0
F
IR
S T
T
IT
L E
F -3
C
O N
S O
L
ID
A T
E D
W E
A P
O N
S F
A C
IL
IT
Y
J A
X -A
N G
-W L T
-F .R
V T
B-3 100% DESIGN SUBMITTAL
ROY MEDEIROS
V VOLT
UNO UNLESS NOTED OTHERWISE
UL UNDERWRITERS LABORATORIES
UFC UNIFIED FACILITIES CRITERIA
UCMS UTILITY CENTRAL MONITORING SYSTEM
SQ. FT. SQUARE FEET
SLC SIGNALING LINE CIRCUIT
RTS REMOTE TEST STATION
RMC RIGID METAL CONDUIT
RF RADIO FREQUENCY
RDU REMOTE DISPLAY UNIT
PIV POST INDICATOR VALVE
OS&Y OUTSIDE STEM AND YOKE
OCP OVERCURRENT PROTECTION
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NC NORMALLY CLOSED
NAC NOTIFICATION APPLIANCE CIRCUIT
MNS MASS NOTIFICATION SYSTEM
LOC LOCAL OPERATOR CONSOLE
HZ HERTZ
HVLS HIGH VOLUME LOW SPEED
HVAC HEATING VENTILATION AND AIR CONDITIONING
FP FIRE PROTECTION
FACU FIRE ALARM CONTROL UNIT
FAA FIRE ALARM ANNUNCIATOR
FA FIRE ALARM
EX EXPLOSION PROOF
EOR ENGINEER OF RECORD
EOLR END-OF-LINE RESISTOR
EMT ELECTRIC METALLIC TUBING
DC DIRECT CURRENT
CO CARBON MONOXIDE
CIS COMMON INTELLIGIBILITY SCALE
CD CANDELA
BLDG BUILDING
AWG AMERICAN WIRE GAUGE
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ARM ADDRESSABLE RELAY MODULE
AOM ADDRESSABLE OUTPUT MODULE
AMP AMPLIFIER BOOSTER PANEL
AIM ADDRESSABLE INPUT MODULE
AHU AIR HANDLING UNIT
AHJ AUTHORITY HAVING JURISDICTION
AFF ABOVE FINISHED FLOOR
ACU AUTONOMOUS CONTROL UNIT
CALLOUT IDENTIFICATION FIRE ALARM LEGEND ABBREVIATIONS APPLICABLE CODES AND STANDARDS GENERAL FIRE ALARM NOTES
WEAPONS
RELEASE SHOP
WEAPONS LOAD
SHOP OFFICE
BREAK ROOM
WING WEAPONS
MANAGER
OFFICE
SHARED OFFICE
VEST 2
CLASSROOM
TEST & TRAINING
WEAPONS
ELEMENT SUPR
NCOIC SUPR
MECH 2
COMM
PPE STORAGE
ELEC
JAN CLOSET
STORAGE
FIRE PROTECT
MECH 1
MEN
CWF HANGAR
LOBBY
CORRIDOR 1
CORRIDOR 2
VEST 1
WOMEN
A MKJHGFEDCB
M A
T C
H L