Attach-2_JAXF35CWF-100P GENERAL CS ARCH DRAWINGS VOLUME 1 OF 3.pdf

PDF 43 MB Posted

Attached to
F-35 CONSTRUCT COMBINED WEAPONS FACILITY Federal contract opportunity
Solicitation number
W50S6Y-25-B-A004
Issued by
Department of the Army Florida Army National Guard

About this file

This file appears to be an architectural drawings package (Volume 1 of 3) for the F-35 Combined Weapons Facility construction project. The drawings package contains general civil and architectural plans for a new 22,696 square-foot Consolidated Weapons Facility at the 125th Fighter Wing, Jacksonville International Airport. The facility includes a Hangar Bay for Load Crew Training, weapons and release systems back-shops, administrative offices, classrooms, break room, and restrooms.

The drawings package appears to be an attachment to solicitation W50S6Y-25-B-A004, which is a small business set-aside construction project with an estimated value between $10M-$25M. The project scope includes environmental remediation, demolition of existing buildings (B1404, B1422, B1022), and installation of asphalt and concrete pavements. The facility will be located on the Flight Line, west of the Sunshades at Jacksonville International Airport.

View the file

Other files for this federal contract opportunity

Other files attached to F-35 CONSTRUCT COMBINED WEAPONS FACILITY, newest first.
File Type Posted
LSGA239001_CWF IFB Abstract 1419-KO.pdf PDF
Bid Submission Day Sign-In Sheet-3APR25.pdf PDF
Q-A set 05G_W50S6Y25BA004 3.28.25 Final.pdf PDF
RFI-0028 REV01-HANGAR DOOR OPENING CLARIFICATIONS AND DETAILS.pdf PDF
RFI-0086 Set 5 Q-3 Louvers locations_Parsons response.pdf PDF
Solicitation Amendment W50S6Y25BA0040002 SF 30 CWF.pdf PDF
Q-A set 04Gp2_W50S6Y25BA004.pdf PDF
CWF Spec 08 34 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Q-A set 04G_W50S6Y25BA004 3.18.25.pdf PDF
RFI-0057 Q-A-29 set 04_Parsons response.pdf PDF
Solicitation Amendment W50S6Y25BA0040001 SF 30 CWF.pdf PDF
CWF Spec 08 36 16.20 Vertical Lift Fabric Hanger Door.pdf PDF
Q-A set 03G_W50S6Y25BA004 3.11.25.pdf PDF
CWF - RFI 0007 ATTACHMENT CU101.pdf PDF
CWF Spec Section 08 34 16 VERTICAL LIFT FABRIC HANGAR DOOR.pdf PDF
Missing Page from 25BA004 Sign In Sheet.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.9.pdf PDF
Q-A set 02G_W50S6Y25BA004 3.7.25.pdf PDF
CWF B-3 DESIGN ANALYSIS - Appendix E.8.pdf PDF
CWF - RFI 0007.pdf PDF
CWF - RFI 0009.pdf PDF
25BA004 Pre-Bid Site Visit PP.pptx PPTX presentation
Q-A set 01G_W50S6Y25BA004 2.28.25.pdf PDF
GeoTech Rpt-Terracon.pdf PDF
Asbestos -Lead Paint Survey-Terracon.pdf PDF
CWF Pre-Proposal minutes.pdf PDF
CWF Sign In Sheet.pdf PDF
Attach-1_JAXF35CWF-100P SPECIFICATIONS.pdf PDF
Attach-4_JAXF35CWF-100P GENERAL MECH PLUM DRAWINGS VOLUME 3 OF 3.pdf PDF
Attach-5_BrandName (FAR 6)_BestCores-A- COR-KO_Redacted.pdf PDF
Solicitation - W50S6Y25BA004 Construct CWF.pdf PDF
Attach-3_JAXF35CWF-100P GENERAL FP ELECT TELE DRAWINGS VOLUME 2 OF 3.pdf PDF
Attach-6_BrandName (FAR 6)_Advantor-B COR-KO_Redacted.pdf PDF
Attach-7_BrandName (FAR 6)_Monaco-C-COR-KO_Redacted.pdf PDF
Attach-8_BrandName (FAR 6)_MMetasys-D-COR-KO_Redacted.pdf PDF
Attach-9_125FW Form 2 Access request (Aug 2023).pdf PDF
Show all 36

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P A

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

TASK ORDER NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

Florida Air

National Guard ®

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

CLIENT LOGO

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

G-001

CWF

C O

V E

R S

H E

E T

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A J G

A R

Z A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-A .R

V T

W50S6Y24F0001

FA8903-21-D-0011

JANUARY 2025

VOLUME 1 OF 3

JACKSONVILLE, FLORIDA

F-35 CONSOLIDATED WEAPONS FACILITY

B-3 100% DESIGN SUBMITTAL

W50S6Y24F0001

W S

Y

F

CWF LOCATIONPROJECT LOCATION

NN

PROJECT # LSGA239001

STANLEY GEORGE

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

P

R S

O N

S G

O V

E R

N M

E N

T S

E R

V

IC

E S

I N

C

W

E S

T W

A L N

U T

S T

R E

E T

(6

-2

P A

S A

D E

N A

C A

L

IF

O R

N

IA

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D x

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

T A

S K

O R

D E

R N

O

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

NOT FOR

CONSTRUCTION

F

IL

E N

A M

E

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

J A

C K

S O

N V

IL

L E

A

IR

N A

T

IO

N A

L G

U A

R D

G-002

CWF

IN

D

E X

O F

D R

A W

IN

G

S

V O

L U

M E o f

J A

C K

S O

N V

IL

L E

F

L O

R

ID

A J G

A R

Z A

R M

A R

T

IN

E Z

S

B

S G

E O

R G

E

R D

E L

A R

O S

A

J A

N U

A R

Y

W S

Y

F

F A

-2

-D

-0

F

IR

S T

T

IT

L E

F -3

C

O N

S O

L

ID

A T

E D

W E

A P

O N

S F

A C

IL

IT

Y

J A

X -A

N G

-W L T

-A .R

V T

B-3 100% DESIGN SUBMITTAL

VOLUME 1 of 3

ARCHITECTURAL

SHEET ID SHEET TITLE

A-001 ARCHITECTURAL ABBREVIATIONS AND SYMBOLS

A-002 GENERAL NOTES

A-003 ACCESSIBILITY INFORMATION

A-011 AIRCRAFT CLEARANCE REQUIREMENT PLAN

A-012 AIRCRAFT CLEARANCE REQUIREMENT SECTIONS

A-021 AIR BARRIER DIAGRAM ENCLOSURE FLOOR PLAN

A-022 AIR BARRIER ENCLOSURE SECTIONS

A-024 HANGAR BAY STRIPING FLOOR PLAN

AP001 PLANTING PLAN

AS001 SITE PLAN

A-101 FLOOR PLAN - OVERALL

A-102 FLOOR PLAN - AREA A

A-103 FLOOR PLAN - AREA B

A-104 FLOOR PLAN - AREA C

A-131 ROOF PLAN - OVERALL

A-141 REFLECTED CEILING PLAN - OVERALL

A-142 REFLECTED CEILING PLAN - AREA A

A-143 REFLECTED CEILING PLAN - AREA B

A-144 REFLECTED CEILING PLAN - AREA C

A-201 ELEVATIONS - NORTH AND SOUTH OVERALL

A-202 ELEVATIONS - EAST AND WEST OVERALL

A-203 ELEVATION - SOUTH

A-204 ELEVATION - NORTH

A-205 ELEVATIONS - EAST AND WEST

A-206 EXTERIOR ELEVATIONS - ENLARGED

A-301 BUILDING CROSS SECTION - OVERALL

A-302 BUILDING LONGITUDINAL SECTIONS - OVERALL

A-303 BUILDING CROSS SECTIONS

A-304 BUILDING CROSS SECTIONS

A-305 BUILDING LONGITUDINAL SECTIONS

A-306 BUILDING LONGITUDINAL SECTIONS

A-307 BUILDING LONGITUDINAL SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 WALL SECTIONS

A-314 WALL SECTIONS

A-321 WALL SECTION DETAILS

A-322 WALL SECTION DETAILS

A-401 ENLARGED FLOOR PLANS

A-402 ENLARGED FLOOR PLANS

A-403 ENLARGED ROOF PLANS

A-405 ENLARGED MECH YARD PLANS AND ELEVATIONS

A-406 ENLARGED MECH YARD DETAILS

A-411 ENLARGED REFLECTED CEILING PLANS

A-421 INTERIOR ELEVATIONS

A-422 INTERIOR ELEVATIONS

A-423 INTERIOR ELEVATIONS

A-501 PLAN DETAILS

A-502 PLAN DETAILS

A-511 ROOF DETAILS

A-512 ROOF DETAILS

A-513 ROOF DETAILS

A-514 ROOF DETAILS

A-515 ROOF DETAILS

A-521 CEILING DETAILS

A-522 CEILING DETAILS

A-523 LIGHTING FIXTURE DETAILS

A-531 MISCELLANEOUS DETAILS

A-601 PARTITION TYPES

A-603 PARTITION DETAILS

A-604 PARTITION FRAMING DETAILS

A-605 PARTITION BACKING PLATE DETAILS

A-611 DOOR SCHEDULE AND TYPES

A-612 DOOR AND FRAME TYPES

A-613 DOOR DETAILS

A-614 DOOR DETAILS

A-615 DOOR DETAILS

A-621 WINDOW SCHEDULE AND TYPES & LOUVER SCHEDULE

A-622 TRANSLUCENT WINDOW TYPES

A-623 TRANSLUCENT WINDOW TYPES

A-624 WINDOW DETAILS

A-625 LOUVER DETAILS

A-626 TRANSLUCENT PANEL DETAILS

A-627 STOREFRONT DETAILS

A-821 MILLWORK DETAILS

A-901 PERSPECTIVE VIEWS

INTERIORS

SHEET NO. SHEET TITLE

I-101 FURNITURE PLAN

I-102 FURNITURE PLAN - AREA B

I-103 FINISH FLOOR PLAN - OVERALL

I-104 FINISH FLOOR PLAN - AREA A

I-105 FINISH FLOOR PLAN - AREA B

I-106 FINISH FLOOR PLAN - AREA C

I-107 SIGNAGE PLAN - OVERALL

I-108 SIGNAGE PLAN - AREA A

I-109 SIGNAGE PLAN - AREA B

I-110 SIGNAGE PLAN - AREA C

I-501 INTERIOR FINISH DETAILS

I-601 FINISH SCHEDULE AND LEGEND

I-602 SIGNAGE SCHEDULE

I-603 SIGNAGE TYPES

I-604 SIGNAGE TYPES

I-605 SIGNAGE TYPES

GENERAL

SHEET ID SHEET TITLE

G-001 COVER SHEET

G-002 INDEX OF DRAWINGS (VOLUME 1 of 3)

G-003 INDEX OF DRAWINGS (VOLUME 2 of 3)

G-004 INDEX OF DRAWINGS (VOLUME 3 of 3)

CIVIL

SHEET NO. SHEET TITLE

C-001 LEGEND AND ABBREVIATIONS

C-002 GENERAL NOTES, SAFETY AND SECURITY NOTES

VF101 EXISTING CONDITIONS PLAN

CD101 DEMOLITION PLAN

CS101 SITE PLAN

CS501 CIVIL DETAILS - 1

CS502 CIVIL DETAILS - 2

CG101 GRADING PLAN

CG121 EROSION AND SEDIMENT CONTROL PLAN

CG201 STORM DRAIN PROFILES

CG501 EROSION CONTROL DETAIL - 1

CG502 EROSION CONTROL DETAIL - 2

CU101 UTILITY LAYOUT PLAN - 1

CU102 UTILITY LAYOUT PLAN -2

CU501 UTILITY DETAILS - 1

CU502 UTILITY DETAILS - 2

CU503 UTILITY DETAILS - 3

CU504 UTILITY DETAILS - 4

CU505 UTILITY DETAILS - 5

STRUCTURAL

SHEET NO. SHEET TITLE

S-001 GENERAL STRUCTURAL NOTES

S-002 GENERAL STRUCTURAL NOTES

S-003 GENERAL STRUCTURAL NOTES

S-004 SPECIAL INSPECTION SHEDULE

S-005 SPECIAL INSPECTION SHEDULE

S-006 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-007 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-008 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-009 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-010 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-011 WIND LOAD DIAGRAMS - COMPONENTS & CLADDING

S-101 OVERALL FOUNDATION PLAN

S-102 FOUNDATION PLAN - AREA A

S-103 FOUNDATION PLAN - AREA B

S-104 FOUNDATION PLAN - AREA C

S-105 OVERALL FLOOR SLAB PLAN

S-106 FLOOR SLAB PLAN - AREA A

S-107 FLOOR SLAB PLAN - AREA B

S-108 FLOOR SLAB PLAN - AREA C

S-109 OVERALL ROOF FRAMING - PLAN

S-110 ROOF FRAMING PLAN - AREA A

S-111 ROOF BOTTOM CHORD FRAMING PLAN - AREA A

S-112 ROOF FRAMING PLAN - AREA B

S-113 ROOF FRAMING PLAN - AREA C

S-201 STEEL FRAME ELEVATIONS

S-202 STEEL FRAME ELEVATIONS

S-203 STEEL FRAME ELEVATIONS

S-204 CMU WALL ELEVATIONS

S-205 CMU WALL ELEVATIONS

S-206 CMU WALL ELEVATIONS

S-301 BUILDING SECTIONS

S-302 BUILDING SECTIONS

S-303 WALL SECTIONS

S-304 WALL SECTIONS

S-305 WALL SECTIONS

S-306 WALL SECTIONS

S-307 WALL SECTIONS

S-308 WALL SECTIONS

S-309 WALL SECTIONS

S-310 WALL SECTIONS

S-501 STANDARD CONCRETE DETAILS

S-502 STANDARD CONCRETE DETAILS

S-503 STANDARD CONCRETE DETAILS

S-504 STANDARD CONCRETE DETAILS

S-505 STANDARD CONCRETE DETAILS

S-506 STANDARD MASONRY DETAILS

S-507 STANDARD MASONRY DETAILS

S-508 STANDARD MASONRY DETAILS

S-509 STANDARD MASONRY DETAILS

S-510 STANDARD ROOF DECK & JOIST DETAILS

S-511 STANDARD ROOF DECK & JOIST DETAILS

S-512 STANDARD STEEL DETAILS

S-513 STANDARD STEEL DETAILS

S-514 STANDARD STEEL DETAILS

S-515 STANDARD STEEL DETAILS

S-516 BASE PLATE DETAILS

S-517 HANGAR AND DRAG CONNECTION DETAILS

S-518 STEEL FRAMING SECTIONS AND DETAILS

S-520 TRUSS ELEVATIONS

S-521 TRUSS ELEVATIONS

S-522 TRUSS ELEVATIONS

S-601 STEEL COLUMN SCHEDULE

S-901 3D REPRESENTATION

S-902 3D REPRESENTATION

STANLEY GEORGE

T

CETIHCRADER

ET

SI

G E

R

FOETAT

S

RO

EG

SLGUOD

YEL

NAT S

A

E G

AR102462

F L OR I D

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

C-001

LE

G

EN

D

A N

D A

BB

R

EV

IA

TI

O

N S

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

1.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

AASHTO AMERICAN ASSOCIATION OF STATE HIGHWAY AND

TRANSPORTATION OFFICIALS

ABV ABOVE

AC ASPHALT CONCRETE

ACC ACCESSIBLE

ACI AMERICAN CONCRETE INSTITUTE

ADDM ADDENDUM

ADJ ADJACENT, ADJOINING, ADJUSTABLE

AFCEC AIR FORCE CIVIL ENGINEERING CENTER

AFFF AQUEOUS FILM FORMING FOAM

AGGR AGGREGATE

AI AREA INLET

ALGN ALIGNMENT

ALT ALTERNATE

APPD APPROVED

APPROX APPROXIMATE

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASPH ASPHALT

B/C BACK OF CURB

BDRY BOUNDARY

BITUM BITUMINOUS

BLDG BUILDING

BLW BELOW

BM BENCHMARK

BO BOTTOM OF

BOC BACK OF CONCRETE CURB

BOT BOTTOM

BS BOTH SIDES

BTWN BETWEEN

BW BOTH WAYS

CAP CAPACITY

CB CATCH BASIN

CE COVER ELEVATION

CEM CEMENT

CES CIVIL ENGINEERING SQUADRON

CCI CAST IRON

C/F CURB FACE

CI CURB INLET

CIP CAST-IN-PLACE

CIRC CIRCULAR

CJ CONTROL JOINT

CJ CONSTRUCTION JOINT

CCLL CONTRACT LIMIT LINE

C/L CENTER LINE

CLOS CLOSURE

CLR CLEAR(ANCE)

CNR CORNER

CO CLEANOUT

CONC CONCRETE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COR CONTRACTING OFFICER'S REPRESENTATIVE

COV COVER

CRCMF CIRCUMFERENCE

CRS COURSE(S)

CSK COUNTERSUNK

CSMT CASEMENT

CT CERAMIC TILE

CT CURRENT TRANSFORMER

C TO C CENTER TO CENTER

CTR CENTER

CU FT CUBIC FEET

CU YD CUBIC YARDS

DAT DATUM

DCJ DOWELED CONTROL JOINT

DEG DEGREE

DEMO DEMOLITION

DEPR DEPRESSION

DET DETAIL

DIA DIAMETER

DIM DIMENSION

DR DRAIN

DW DOMESTIC WATER

DWG DRAWING

DWLS DOWELS

DWR DRAWER

E EAST

EA EACH

ECF ENTRY CONTROL FACILITY

EF EACH FACE

EG EXISTING GRADE

EIS ENVIRONMENTAL IMPACT STATEMENT

EJ EXPANSION JOINT

EL ELEVATION - GRADE OR BUILDING

ENCL ENCLOSURE

ENTR ENTRANCE, ENTERING

ENVIR ENVIRONMENTAL

EOI END OF INFORMATION

EOP EDGE OF PAVEMENT

EPY EPOXY COATING

EQ EQUAL

ERP ENVIRONMENTAL RESOURCE PERMITTING

EST ESTIMATE(D)

EXC EXCAVATE

EXST EXISTING

EXP EXPANSION

EXP EXPOSED

EXT EXTERIOR

FANG FLORIDA AIR NATIONAL GUARD

FCG FACING

FDEP FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION

FF FINISHED FLOOR (ELEVATION)

FG FINISH GRADE

FJT FLUSH JOINT

FLEX FLEXIBLE

FL FLOW LINE

FM FORCE MAIN

FN FENCE

FOC FACE OF CONCRETE

FS FUEL STAND

F/S FINISH SURFACE

FT FEET

FUT FUTURE

FW FIRE WATER

G NATURAL GAS

GAL GALLON(S)

GALV GALVANIZED

GALV STL GALVANIZED STEEL

GB GRADE BREAK

GC GENERAL CONTRACTOR

GEN GENERAL

GOVT GOVERNMENT

GPM GALLONS PER MINUTE

GR LN GRADE LINE

HNDRL HANDRAIL

HDPE HIGH DENSITY POLYETHYLENE PIPE

HOR HORIZONTAL

HP HIGH POINT

HR HOUR

HT HEIGHT

HW HAZARDOUS WASTE STORAGE AREA

HWY HIGHWAY

IN INCH

INCL INCLUDED

INV INVERT

IRP INSTALLATION RESTORATION PROGRAM

JT JOINT

LB POUND

LF LINEAR FEET

LG LENGTH

LIN LINEAR

LOW LIMIT OF WORK

LPT LOW POINT

ME MATCH EXISTING

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MOD MODIFIED

N NORTH

NGB NATIONAL GUARD BUREAU

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NPS NOMINAL PIPE SIZE

NTS NOT TO SCALE

OC ON CENTER

OCEW ON CENTER EACH WAY

OD OUTSIDE DIAMETER

OH OVERHEAD

OPNG OPENING

OPP OPPOSITE

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION

PAR PARALLEL

PCC PORTLAND CEMENT CONCRETE

PCF POUNDS PER CUBIC FOOT

PD PAVEMENT DRAIN

PEA PROGRAMMATIC ENVIRONMENTAL ASSESSMENT

PFAS PERFLUOROALKYL, POLYFLUOROAKLYL SUBSTANCES

PH PHASE

PI POINT OF INTERSECTION

PIV POST INDICATOR VALVE

PL PROPERTY LINE

POC POINT OF CONNECTION

POL PETROLEUM, OIL, & LUBRICANTS

PREFMD PREFORMED

PRKG PARKING

PMO PROGRAM MANAGEMENT OFFICE

PROJ PROJECT

PSI POUNDS PER SQUARE INCH

PT POINT

PV PAVED

PVC POLYVINYL CHLORIDE

PVG PAVING

PVMT PAVEMENT

QTY QUANTITY

R RADIUS

RCB REINFORCED CONCRETE BOX

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

REF REFERENCE

REINF REINFORCE

REM REMOVE(ABLE)

REQD REQUIRED

REV REVISION

RIM TOP OF COVER

ROW RIGHT OF WAY

S SOUTH

SC STORAGE CANOPY

SCHED SCHEDULE

SD STORM DRAIN

SHT SHEET

SIN STORM INLET

SSLNT SEALANT

SQ SQUARE

SS SANITARY SEWER

STA STATION

STD STANDARD

STOR STORAGE

SW SIDEWALK

TAN TANGENT

TEMP TEMPORARY

THK THICK(NESS)

THRES THRESHOLD

TC, T/C TOP OF CURB

TO TOP OF

TOG TOP OF GRATE

TOPO TOPOGRAPHY

TOS TOP OF SLAB

TOW TOP OF WALL

TRANS TRANSVERSE

TYP TYPICAL

UGND UNDERGROUND

UNEX UNEXCAVATED

UNFIN UNFINISHED

UON UNLESS OTHERWISE NOTED

USACE UNITED STATES ARMY CORPS OF ENGINEERS

UTIL UTILITY

VOL VOLUME

W WEST

W/ WITH

W/O WITHOUT

WTH WIDTH

ABBREVIATIONSLEGEND

APPROXIMATE SURVEY LIMITS

PROJECT LIMITS

DEMOLISH EXISTING ASPHALT PAVEMENT

DEMOLISH EXISTING CONCRETE PAVEMENT

DEMOLISH EXISTING LANDSCAPING

DEMOLISH EXISTING BUILDING

DEMOLISH EXISTING FENCE

DEMOLISH EXISTING UTILITY LINE

CONCRETE PAVEMENT

ASPHALT PAVEMENT

APPROXIMATE PROPOSED MONITORING WELLS LOCATION

DEMOLISH EXISTING FOUNDATION

DEMOLISH EXISTING UTILITY STRUCTURE

BOLLARD

GUY ANCHOR

I-BEAM

AIR CONDITIONING UNIT

SANITARY SEWER LINE

SANITARY SEWER MANHOLE

STORM DRAIN LINE

STORM DRAIN MANHOLE

WATER LINE

WATER VALVE

HOSE BIB

FIRE HYDRANT

ELECTRICAL LINE

ELECTRICAL FIXTURE

ELECTRICAL MANHOLE

HANDHOLE

LIGHT POLE

LANDSCAPE LIGHTING

COMMUNICATIONS LINE

COMMUNICATIONS MANHOLE

UNKNOWN UTILITY LINE

UNKNOWN UTILITY MANHOLE

UTILITY VAULT

MONITORING WELL

TEST HOLE

TRAFFIC SIGN

TRAVERSE POINT

CONTOUR

FIRE WATER LINE

FIRE WATER SHUTOFF VALVE

CATCH BASIN

TOE OF SLOPE

TOP OF BANK

POST INDICATOR VALVE

ELECTRICAL VAULT

W

SD

SAN

E

F

EXISTING PROPOSED

CB

S

S

E

COMM

EDWARD HICKEY

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

C-002

G

EN

ER

AL

N O

TE

S, S

AF

ET

Y

AN

D

SE

C

U R

IT

Y

N O

TE

S

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

2.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

GENERAL PROJECT NOTES:

1. COORDINATE THE DISCONNECTION OF UTILITIES THROUGH THE COR. DEMOLITION SHALL NOT

BEGIN UNTIL WRITTEN BASE APPROVAL IS RECEIVED. ALL EXISTING UTILITIES ARE TO BE

TERMINATED AT THEIR POINT OF CONNECTION TO THE MAINS. WHERE CONNECTIONS OF NEW

UTILITIES TO EXISTING UTILITIES ARE SHOWN ON THE PLANS, THE CONTRACTOR SHALL EXPOSE

THE EXISTING LINES AT THE PROPOSED CONNECTIONS TO VERIFY THE LOCATIONS, SIZES,

MATERIAL TYPES AND DEPTHS PRIOR TO EXCAVATION FOR THE NEW LINES.

2. THE CONTRACTOR SHALL EXPOSE, VERIFY AND BACKFILL ALL EXISTING UNDERGROUND UTILITIES AND STRUCTURES AT UTILITY CROSSINGS PRIOR TO EXCAVATION OF PIPELINE TRENCH. UTILITY CROSSINGS AT A DEPTH GREATER THAN 12-INCHES BELOW TRENCH BOTTOM DO NOT NEED TO BE EXPOSED. UTILITY ALIGNMENT AND GRADE MAY BE CHANGED IF THERE ARE CONFLICTS WITH ANY EXISTING UNDERGROUND UTILITIES AND STRUCTURES, WHETHER SHOWN ON THE PLANS OR NOT.

COORDINATE WITH THE COR PRIOR TO MAKING CHANGES.

ACCESS AND SAFETY NOTES:

1. THE EXISTING BASE ROAD SPEED LIMITS AND LOAD LIMITS ARE STRICTLY ENFORCED. ALL

CONCRETE TRUCKS SHALL PUT DOWN EXTRA AXLES WHEN TRAVELING ON GOVERNMENT

PROPERTY.

2. CONTRACTOR SHALL COORDINATE WITH THE COR CONCERNING ANY GOVERNMENT-OWNED

EQUIPMENT REQUIRING RELOCATION TO COMPLETE PROJECT WORK.

STOCKPILE HEIGHT:

1. CONTRACTOR SHALL ENSURE THAT STOCKPILES ARE MANAGED AND DISPOSED OF IN

ACCORDANCE WITH THE ENVIRONMENTAL GENERAL REQUIREMENTS. CONTRACTOR SHALL NOT

STOCKPILE CONSTRUCTION MATERIALS, SPOILS, OR DEBRIS IN ANY AREA WHERE SUCH

STOCKPILES WOULD PENETRATE AVIATION SURFACES. ALL STOCKPILES ADJACENT TO AIRCRAFT OPERATIONS AREA SHALL BE IDENTIFIED WITH A 360-DEGREE RED OBSTRUCTION LIGHT PLACED

AT THE HIGHEST POINT OF THE STOCKPILE.

EXCAVATION AND TRENCHES:

1. CONTRACTOR SHALL COMPLY WITH THE MOST CURRENT EDITION OF OSHA REGULATIONS, THE

STATE OF FLORIDA LAWS CONCERNING EXCAVATION, AND USACE EM 385-1-1 SAFETY AND HEALTH

REQUIREMENT MANUAL.

2. DUE TO AN ONGOING PFAS REMEDIAL INVESTIGATION INTO THE SOIL AND GROUNDWATER AT

FANG, COORDINATION WITH FDEP IS REQUIRED BEFORE STARTING EXCAVATION.

3. DEWATERING OF UTILITY TRENCHES AND OTHER EXCAVATIONS MAY BE REQUIRED, SEE

GEOTECHNICAL BORING LOGS.

4. ALL SOILS REMOVED FROM THESE SITES WILL REQUIRE CHARACTERIZATION AND PROPER

DISPOSAL. SOIL ANALYSIS THAT CONFIRMS THE PRESENCE OF PFAS WILL NEED TO BE DISPOSED OF IN A FACILITY THAT ACCEPTS PFAS CONTAMINATED SOILS. GROUND WATER AT THESE SITES

HAS ALSO BEEN IMPACTED. GROUNDWATER CAN BE CONTAINERIZED AND DISPOSED OF AT

FACILITIES THAT ACCEPT CONTAMINATED GROUNDWATER. IT CAN ALSO BE TREATED ON SITE.

CONTRACTORS WILL NEED TO COMPLY WITH FLORIDA REGULATIONS REGARDING THE REMOVAL

OF CONTAMINATED GROUNDWATER.

5. ALL WORK IN AND ADJACENT TO STREETS OR ROADS SHALL BE COORDINATED WITH THE COR. THE

CONTRACTOR SHALL PROVIDE THE COR WITH A ONE-WEEK ADVANCE NOTICE PRIOR TO

BEGINNING OF WORK ADJACENT TO BASE ROADWAYS. NO WORK ADJACENT TO OR ON EXISTING

ROADS SHALL BE INITIATED WITHOUT PRIOR APPROVAL FROM THE COR.

6. DIG PERMITS ARE REQUIRED BEFORE STARTING EXCAVATION AT SITE.

7. CRANE PERMIT REQUIRED FOR CRANE USE AT SITE.

OTHER SAFETY REQUIREMENTS:

1. CONTRACTOR SHALL COORDINATE THE RELOCATION AND SALVAGE OF ANY GOVERNMENT OWNED

EQUIPMENT WITH THE CONTRACTING OFFICER.

2. CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO CONTROL/PREVENT DUST CAUSED BY

CONSTRUCTION ACTIVITIES TO A LIMIT ACCEPTABLE TO BASE OPERATIONS. THE CONTRACTOR

SHALL CONTROL/PREVENT BLOWING DUST ON THE PROJECT SITE FROM ANY HAUL ROUTE OR

WORK AREA REGARDLESS OF SOURCE.

3. GASOLINE, DIESEL FUEL, OIL, AND HAZARDOUS WASTE RESULTING FROM CONTRACTOR'S

OPERATIONS OR ACTIVITIES SHALL BE PROPERLY DISPOSED OF IN ACCORDANCE WITH THE

SPECIFICATIONS AND LOCAL REGULATORY REQUIREMENTS AND PROPERLY REMOVED FROM THE

PROJECT PROPERTY. IF HAZARDOUS MATERIALS ARE ENCOUNTERED OR UNCOVERED DURING

CONSTRUCTION ACTIVITIES, THE CONTRACTOR SHALL IMMEDIATELY STOP WORK AND NOTIFY THE

CONTRACTING OFFICER.

4. CONTRACTOR SHALL PROVIDE KEY ACCESS TO ALL CONSTRUCTION GATES TO THE BASE FIRE

DEPARTMENT DURING CONSTRUCTION. COORDINATE ACCESS PADLOCKS AND KEYS WITH THE

CONTRACTING OFFICER.

NIGHT WORK:

1. ALL TEMPORARY CONSTRUCTION LIGHTING SHALL BE COORDINATED WITH JACKSONVILLE AIR

NATIONAL GUARD SECURITY AND AIRFIELD OPERATIONS FOR APPROVAL OF LOCATIONS, HEIGHT, AND DIRECTION. IF NIGHT WORK IS REQUIRED AND APPROVED BY THE CONTRACTING OFFICER, WORK LIGHTS FOR NIGHT WORK ON THE BASE SHALL BE POSITIONED SUCH THAT THE LIGHT WILL

NOT BE DIRECTED TOWARD THE CONTROL TOWER OR AIRCRAFT UTILIZING THE RUNWAY AND

AIRFIELD INCLUDING APPROACHES. COORDINATE WITH BASE OPERATIONS AND REQUEST

ACTIVITY 5 DAYS IN ADVANCE.

SECURITY REQUIREMENTS:

1. ALL CONTRACTOR EMPLOYEES SHALL CARRY CONTRACTOR PHOTO IDENTIFICATION AT ALL TIMES

WHILE WORKING INSIDE THE BASE SECURE PERIMETER.

2. CONTRACTOR EMPLOYEES SHALL COMPLY WITH ANY INTEGRATED DEFENSE MEASURES THAT

MAY BE NECESSARY DURING CONTINGENCY OPERATIONS. THIS INCLUDES, BUT IS NOT LIMITED TO, VEHICLE INSPECTIONS, IDENTIFICATION CHECKS, ETC.

FINISHED FLOOR ELEVATIONS:

1. ELEVATIONS SHOWN ON CIVIL DRAWINGS ARE BASED ON TOPOGRAPHICAL SURVEY DATA.

ELEVATIONS SHOWN ON OTHER DRAWINGS ARE ASSUMED. CONTRACTOR TO CORRELATE

BETWEEN THE ELEVATIONS PROVIDED.

GENERAL NOTES:

1. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN FEET UNLESS INDICATED.

2. ALL PIPE SIZES ARE IN INCHES UNLESS INDICATED OTHERWISE.

EXISTING CONDITION NOTES:

1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES AS INDICATED HAVE BEEN

OBTAINED FROM EXISTING RECORDS AND FIELD SURVEYS. UNDERGROUND STRUCTURES AND

UTILITIES MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED.

2. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING CONDITIONS AND BE THOROUGHLY FAMILIAR

WITH THE SITE BEFORE ANY WORK COMMENCES. ANY DISCREPANCIES IN THE DRAWINGS SHALL

BE IMMEDIATELY REPORTED TO THE COR BEFORE ANY FURTHER WORK COMMENCES.

GENERAL DEMOLITION NOTES:

1. LOCATIONS NOTED FOR DEBRIS REMOVAL MAY CONTAIN ANY OF THE FOLLOWING MATERIALS:

AGGREGATE, CONCRETE, ASPHALT, MASONRY, FOUNDATIONS, REBAR, FENCE MATERIAL, PIPING, AND MISCELLANEOUS STRUCTURES. LARGE PIECES OF MATERIAL MAY NEED TO BE CRUSHED

AND/OR BROKEN UP FURTHER IN ORDER TO BE HAULED OFF BASE TO THE WASTE DISPOSAL SITE.

2. PAVEMENT DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL DEPTH. EXISTING PAVEMENT

EDGES SHALL BE SAWCUT IN LOCATIONS SHOWN TO PROVIDE CLEAN EDGE FOR CONSTRUCTION

OF PROPOSED PAVEMENT.

3. CONCRETE PAVEMENT REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING PAVEMENT JOINT

TO THE GREATEST EXTENT POSSIBLE TO PREVENT PARTIAL PANEL REMOVAL.

4. PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT AND ANY BASE AND SUBBASE

MATERIAL PRESENT.

5. CONTRACTOR SHALL COORDINATE WITH THE COR PRIOR TO AND CONTACT THE APPROPRIATE

PRIVATIZED UTILITY COMPANY FOR REMOVAL OF EXISTING UTILITIES CURRENTLY IN SERVICE.

RELOCATED UTILITIES SHALL BE CONSTRUCTED BEFORE REMOVAL OF EXISTING UTILITIES TO

ENSURE UNINTERRUPTED SERVICE TO THE FACILITIES SERVED BY THE UTILITY. ALL RELOCATIONS

SHALL BE COORDINATED WITH THE COR.

6. UTILITY DEMOLITION INCLUDES THE REMOVAL OF THE PIPE/CONDUIT/STRUCTURE AND ALL

PERMEABLE BACKFILL/ANNULUS MATERIAL AND THEN BACK FILLED WITH LOW PERMEABILITY

MATERIAL. UTILITY CAPPING METHODS SHALL BE IN ACCORDANCE WITH MANUFACTURER'S

RECOMMENDATIONS FOR SPECIFIC PIPE MATERIAL. ALL CAPPING SHALL BE INSPECTED AND

APPROVED BY THE COR.

7. ALL EXISTING GRAVITY SEWER MANHOLES THAT WILL REMAIN WITH THEIR INLET OR OUTLET PIPE

REMOVED SHALL HAVE THE OPENING PLUGGED.

GENERAL SITE NOTES:

1. CONTRACTOR SHALL COORDINATE BUILDING ENTRANCES, EGRESSES, WALKWAYS, AND DOORWAY

LOCATIONS WITH ARCHITECTURAL AND STRUCTURAL SHEETS. STOOPS, WHERE PRESENT, AND

SIDEWALKS SHALL BE CENTERED ON DOORS.

2. SEE MECHANICAL AND ELECTRICAL SHEETS FOR MISCELLANEOUS SITE EQUIPMENT DETAILS. SEE

STRUCTURAL SHEETS FOR EQUIPMENT PAD DETAILS.

GENERAL UTILITY NOTES:

1. CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL BUILDING CONNECTIONS WITH BUILDING

CONTRACTOR, UTILITY COMPANIES AND THE INFORMATION PROVIDED ON CIVIL, MECHANICAL AND

ELECTRICAL SHEETS.

SANITARY UTILITY NOTES:

1. SEE DETAILS FOR CONCRETE SEWER ENCASEMENT WHERE SANITARY SEWER WILL BE INSTALLED

ABOVE WATER LINES. SEE SPECIFICATIONS FOR ADDITIONAL CLEARANCE REQUIREMENTS FOR

SANITARY PIPING.

2. MANHOLES INDICATED ON SANITARY LINES SHALL HAVE A MINIMUM 0.10 FOOT DROP IN ELEVATION

BETWEEN THE INCOMING AND OUTGOING SEWER UNLESS INDICATED OTHERWISE. INVERT FLOW

CHANNELS SHALL BE CONSTRUCTED TO PROVIDE SMOOTH AND UNIFORM SLOPE WITH GRADUAL

TRANSITION SECTIONS.

UTILITY STRUCTURE NOTES:

1. ALL (VEHICULAR TRAFFIC AREAS) UTILITY STRUCTURES ARE TO BE H-20 RATED.

2. ALL (AIRCRAFT APRON AREAS) UTILITY STRUCTURES ON THE AIRFIELD ARE TO BE AIRCRAFT

RATED PER UNIFORM FACILITY CODE (UFC) 3-260-01 AS FOLLOWS:

a. LOAD-BEARING PAVEMENTS AND PAVED SHOULDERS

I. FOR MANHOLE COVERS AND INLET GRATES AND FRAMES, DESIGN FOR A 100,000 LB

WHEEL LOAD WITH 250PSI TIRE PRESSURE.

II. FOR STRUCTURES WITH THEIR SHORTEST SPAN EQUAL TO OR LESS THAN 2 FEET

DESIGN BASED ON A SINGLE WHEEL LOAD OF 100,000 LB AT A CONTACT PRESSURE

OF 250 PSI, OR A UNIFORM LIVE LOAD OVER THE ENTIRE STRUCTURE OF 250 PSI

WHICHEVER IS GREATER.

III. FOR STRUCTURES WITH THEIR SHORTEST SPAN GREATER THAN 2 FEET, DESIGN

BASED ON THE MAXIMUM NUMBER OF WHEELS THAT CAN FIT ONTO THE SPAN,

CONSIDERING THE MOST CRITICAL ASSIGNED AIRCRAFT OPERATING AT ITS MAXIMUM

GROSS WEIGHT. IN NO CASE, HOWEVER, SHOULD THE DESIGN BE BASED ON

COMPUTED STRESS CONDITIONS LESS THAN THOSE CREATED BY A WHEEL LOAD OF

100,000 LB AT A CONTACT PRESSURE OF 250 PSI.

3. MANHOLE RIM ELEVATION SHALL BE FLUSH WITH FINAL GRADE.

4. COVERS AND CASTINGS OF MANHOLES AND STRUCTURES SHALL BE STAMPED PER THE

APPROPRIATE UTILITY TYPE OR PER THE LOCAL STANDARDS, AND SHALL BE STAMPED PER THE

ORIGIN OF MANUFACTURE.

5. COVERS AND CASTINGS SHALL BE TAMPER-PROOF FOR STRUCTURES LOCATED IN PEDESTRIAN

AREAS, EASEMENT AREAS, AND AREAS WITH SPECIAL SECURITY RESTRICTIONS.

6. WATER-TIGHT MANHOLE COVERS ARE REQUIRED FOR ALL STRUCTURES.

GENERAL GRADING NOTES:

1. PROPOSED ELEVATIONS INDICATED ARE FOR TOP OF FINAL GRADE, PAVEMENT, OR STRUCTURE

UNLESS INDICATED OTHERWISE.

2. ELEVATION DENOTED AS “MATCH” ARE INTENDED TO MEET EXISTING GRADE ELEVATIONS.

CONTRACTOR SHALL VERIFY ELEVATIONS AT TIE-INS AND MATCH POINTS PRIOR TO BEGINNING

CONSTRUCTION.

3. EXTERIOR FINISH GRADES AT BUILDING ENTRANCES AND DOORWAY THRESHOLDS SHALL BE

MAXIMUM 0.25 INCHES BELOW BUILDING FINISH FLOOR IF A VERTICAL THRESHOLD IS PROVIDED, AND SHALL BE MAXIMUM 0.5 INCHES BELOW BUILDING FINISH FLOOR IF A BEVELED THRESHOLD IS

PROVIDED, UNLESS INDICATED OTHERWISE. EXTERIOR GRADE SHALL HAVE A 6 INCH DROP

ELSEWHERE UNLESS INDICATED OTHERWISE.

4. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. ANY

DRAINAGE FEATURE OR STRUCTURE DISTURBED DURING CONSTRUCTION SHALL BE RESTORED

TO EXISTING CONDITIONS OR BETTER SUBJECT TO THE APPROVAL OF THE COR.

5. SURFACES AROUND THE FACILITY SHALL BE GRADED TO PROVIDE POSITIVE DRAINAGE AWAY

FROM BUILDINGS AND PAVEMENTS.

6. THE CONTRACTOR SHALL REMOVE STANDING WATER FROM THE PROJECT WORK LIMITS AS

NECESSARY TO PROTECT SUBGRADE, SUBBASE, AND/OR BASE COURSE OF NEW PAVEMENT,

SURROUNDING PAVEMENT-TO-REMAIN, OR OTHER COMPLETED WORKS.

7. TOP ELEVATION OF ALL UTILITY STRUCTURES TO REMAIN SHALL BE ADJUSTED TO MATCH

FINISHED GRADE ELEVATION.

8. ALL GRADED AREAS SHALL BE RE-VEGETATED WITH APPROVED SEED MIXTURE.

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F F

FF

F F

F F

F

FFFFFFFF

F F

F F

FFFF

F

F

F F

F

F F

F

F

F

F

F

F

F F

F

PLAN

NORTH

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

VF101

EX

IS

TI

N

G C

O N

D

IT

IO

N

S

PL

AN

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -V

F1

.d w g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

SHEET NOTES

LEGEND

EXISTING CONDITIONS PLANA4 SCALE: 1" = 30' 30'0'30'

GRAPHIC SCALE

1. REFER TO SHEET C-001 FOR LEGEND AND

ABBREVIATIONS AND SHEET C-002 FOR GENERAL

NOTES.

2. VERIFY EXISTING CONDITIONS PRIOR TO

CONSTRUCTION.

3. VERTICAL INFORMATION IS BASED ON THE NORTH

AMERICAN VERTICAL DATUM OF 1988 (NAVD88).

HORIZONTAL INFORMATION IS BASED ON THE NORTH

AMERICAN DATUM OF 1983 (NAD83), 2011

ADJUSTMENT, FLORIDA EAST ZONE STATE PLANE

COORDINATE SYSTEM.

4. SURVEY WAS PROVIDED BY SOUTHERN SURVEYING

AND MAPPING CORPORATION DATED MARCH 18, 2024

EXCLUDING FIRE WATER LINES, FIRE WATER

SHUTOFF VALVES. FIRE WATER LINES AND FIRE

WATER SHUTOFF VALVES WERE PROVIDED BY

DOCUMENT TITLED "FIGURE J-1A WATER

DISTRIBUTION SIZE AND MATERIAL MAP

JACKSONVILLE IAP" BY AECOM TECHNICAL SERVICES

DATED FEBRUARY 20, 2020.

APPROXIMATE SURVEY LIMITS

EXISTING CONCRETE PAVEMENT

EXISTING ASPHALT PAVEMENT

EXISTING BOLLARD

EXISTING GUY ANCHOR

EXISTING I-BEAM

EXISTING AIR CONDITIONING UNIT

EXISTING SANITARY SEWER

MANHOLE

EXISTING STORM DRAIN LINE

EXISTING STORM DRAIN MANHOLE

EXISTING WATER LINE

EXISTING WATER VALVE

EXISTING HOSE BIB

EXISTING FIRE HYDRANT

EXISTING UNDERGROUND

ELECTRICAL LINE

EXISTING ELECTRICAL FIXTURE

EXISTING ELECTRICAL MANHOLE

EXISTING HANDHOLE

EXISTING LIGHT POLE

EXISTING LANDSCAPE LIGHTING

EXISTING COMMUNICATIONS LINE

EXISTING COMMUNICATIONS

MANHOLE

EXISTING UNKNOWN UTILITY LINE

EXISTING UNKNOWN UTILITY

MANHOLE

EXISTING UTILITY VAULT

EXISTING MONITORING WELL

EXISTING TEST HOLE

EXISTING TRAFFIC SIGN

EXISTING TRAVERSE POINT

EXISTING CONTOUR

EXISTING FIRE WATER LINE (REFER

TO SHEET NOTE 4)

EXISTING FIRE WATER SHUTOFF

VALVE (REFER TO SHEET NOTE 4)

PLAN

NORTH

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

CD101

D

EM

O

LI

TI

O

N P

LA

N

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

D

1.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

SHEET NOTES

KEYNOTES

02.41.01

LEGEND

DEMOLITION PLANA4 SCALE: 1" = 30' 30'0'30'

GRAPHIC SCALE

1. REFER TO SHEET C-001 FOR LEGEND AND ABBREVIATION

AND SHEET C-002 FOR GENERAL NOTES.

2. EXISTING CONDITIONS OUTSIDE OF APPROXIMATE

SURVEY LIMITS WERE PROVIDED FROM SUPPLEMENTAL

INFORMATION. VERIFY ALL EXISTING CONDITIONS PRIOR

TO CONSTRUCTION.

3. EXISTING FIRE WATER LINES AND FIRE WATER SHUTOFF

VALVES WERE PROVIDED BY DOCUMENT TITLED "FIGURE

J-1A WATER DISTRIBUTION SIZE AND MATERIAL MAP

JACKSONVILLE IAP" BY AECOM TECHNICAL SERVICES

DATED FEBRUARY 20, 2020.

4. DEMOLISH BUILDING OVERHANG AND APPURTENANCES

SUPPORTED BY EXISTING BEAMS.

5. BUILDING 1022 CONTAINS ASBESTOS AND LEAD-BASED

PAINT. REMOVE PER LOCAL AND FEDERAL GUIDELINES.

6. PULL BACK COMM FIBER OPTIC CABLE, COIL, AND STORE

IN MAINTENANCE HOLE #8 DURING CONSTRUCTION.

02.41.01 DEMOLISH EXISTING ASPHALT PAVEMENT.

02.41.02 DEMOLISH EXISTING CONCRETE PAVEMENT.

02.41.09

46.25.01

BLDG

#1046

BLDG #1009

BLDG

#1072

PROJECT LIMITS

APPROXIMATE SURVEY LIMITS

EXISTING CONCRETE PAVEMENT

EXISTING ASPHALT PAVEMENT

DEMOLISH EXISTING ASPHALT

PAVEMENT

DEMOLISH EXISTING CONCRETE

PAVEMENT

DEMOLISH EXISTING LANDSCAPING

DEMOLISH EXISTING BUILDING

DEMOLISH EXISTING UTILITY

STRUCTURE

DEMOLISH EXISTING FOUNDATION.

DEMOLISH EXISTING FENCE

DEMOLISH EXISTING UTILITY LINE

EXISTING BOLLARD

EXISTING GUY ANCHOR

EXISTING I-BEAM

EXISTING AIR CONDITIONING UNIT

EXISTING SANITARY SEWER MANHOLE

EXISTING STORM DRAIN LINE

EXISTING STORM DRAIN MANHOLE

EXISTING WATER LINE

EXISTING WATER VALVE

EXISTING HOSE BIB

EXISTING FIRE HYDRANT

EXISTING ELECTRICAL LINE

EXISTING ELECTRICAL FIXTURE

EXISTING ELECTRICAL MANHOLE

EXISTING HANDHOLE

EXISTING LIGHT POLE

EXISTING LANDSCAPE LIGHTING

EXISTING COMMUNICATIONS LINE

EXISTING COMMUNICATIONS MANHOLE

EXISTING UNKNOWN UTILITY LINE

EXISTING UNKNOWN UTILITY MANHOLE

EXISTING UTILITY VAULT

EXISTING MONITORING WELL

EXISTING TEST HOLE

EXISTING TRAFFIC SIGN

EXISTING FIRE WATER LINE (REFER TO

SHEET NOTE 3)

EXISTING FIRE WATER SHUTOFF VALVE

(REFER TO SHEET NOTE 3)

BLDG

#1022

02.41.01

02.41.01

02.41.01

02.41.03 DEMOLISH EXISTING LANDSCAPING.

02.41.04 DEMOLISH EXISTING BUILDING, FOUNDATION, AND

ASSOCIATED PAVEMENT. REFER TO SHEET NOTE 5.

02.41.05

02.41.06 DEMOLISH EXISTING BOLLARD.

02.41.07 DEMOLISH EXISTING FENCE.

02.41.08 REMOVE AND RELOCATE EXISTING HYDRAULIC LIFT.

02.41.09 DEMOLISH EXISTING UNKNOWN UTILITY LINE.

02.41.10 DEMOLISH EXISTING UNDERGROUND ELECTRICAL LINE.

02.41.11 DEMOLISH EXISTING LANDSCAPE LIGHTING.

02.41.13 DEMOLISH EXISTING WATER VALVE.

02.41.15 DEMOLISH EXISTING FIRE HYDRANT.

02.41.17 DEMOLISH EXISTING CATCH BASIN.

02.41.18 DEMOLISH EXISTING AIR CONDITIONING UNIT.

02.41.19 DEMOLISH EXISTING TEST BORE.

02.41.20 DEMOLISH EXISTING MONITORING WELL.

02.41.04

02.41.02

02.41.03

02.41.03

02.41.04

02.41.06

02.41.06

02.41.03

02.41.03

TYP

02.41.07

TYP

02.41.06

02.41.08

02.41.09

02.41.10

02.41.10

02.41.02

02.41.11

02.41.11

02.41.23

02.41.13

02.41.15

02.41.21 DEMOLISH EXISTING GUY ANCHOR.

02.41.14

02.41.16

02.41.17

02.41.17

02.41.18

02.41.19

02.41.19

02.41.19

02.41.19

02.41.20

02.41.21

02.41.22 DEMOLISH EXISTING STORM DRAIN MANHOLE.

02.41.22

02.41.10

F

02.41.23

02.41.23 DEMOLISH EXISTING FIRE WATER LINE.

02.41.02

02.41.07

TYP

02.41.24

DEMOLISH EXISTING STORMWATER OIL AND

WATER SEPARATOR.

DEMOLISH EXISTING UTILITY TRENCH.

02.41.10

DEMOLISH EXISTING FIRE WATER SHUTOFF VALVE.

02.41.24

02.41.19

02.41.05

02.41.05

02.41.23

02.41.02

02.41.18

BLDG

#1422/#1022A

PREVIOUS

BLDG #1404

LOCATION

STORAGE

SHED

STORAGE

SHED

46.25.01

02.41.02 02.41.01

02.41.04

02.41.04

02.41.14 DEMOLISH EXISTING HOSE BIB.

02.41.16 DEMOLISH EXISTING COMMUNICATIONS LINE. REFER TO

SHEET NOTE 6.

02.41.25 DEMOLISH EXISTING COMMUNICATIONS LINE.

02.41.25

PLAN

NORTH

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

PROPOSED EXTERIOR

COVERED STORAGE

PROPOSED EXTERIOR

COVERED STORAGE

PROPOSED CWF

BLDG

LEGEND

CWF

CS101

SI

TE

P

LA

N

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

S1

.d w g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

SHEET NOTES

KEYNOTES

32.12.01

SITE PLANA4 SCALE: 1" = 30' 30'0'30'

GRAPHIC SCALE

1. REFER TO SHEET C-001 FOR LEGEND AND

ABBREVIATION AND SHEET C-002 FOR GENERAL

NOTES.

2. EXISTING CONDITIONS OUTSIDE OF APPROXIMATE

SURVEY LIMITS WERE PROVIDED FROM

SUPPLEMENTAL INFORMATION. VERIFY ALL EXISTING

CONDITIONS PRIOR TO CONSTRUCTION.

3. CONTRACTOR MUST SUBMIT HOIST FOUNDATION SHOP

DRAWINGS AND STRUCTURAL CALCULATIONS FOR

REVIEW AND APPROVAL PRIOR TO COMMENCING

WORK, STAMPED AND SIGNED BY A REGISTERED

PROFESSIONAL CIVIL OR STRUCTURAL ENGINEER

LICENSED IN THE STATE OF FLORIDA, INDICATING THE

REQUIRED HOIST FOUNDATION REBAR (ITEM 2) IN

ACCORDANCE WITH THE CURRENT FLORIDA BUILDING

CODE (FBC), ASCE 7, AND ACI 318.

4. CONTRACTOR MUST SUBMIT STEEL SHOP DRAWINGS

FOR REVIEW AND APPROVAL, FOR THE BOTTOM

COLUMN SUPPORT (ITEM 1), EMBEDDED STEEL ANGLE

(ITEM 4&5) AND HEADED STUD ANCHORS (ITEM 3), AT

THE PERIMETER OF THE HOIST FOUNDATION, MITER

CUT AND SEAL WELD ANGLES AT ALL FOUR CORNERS.

5. HOIST FOUNDATION SUBGRADE MUST BE PREPARED

AND COMPACTED IN ACCORDANCE WITH THE PROJECT

GEOTECHNICAL REPORT, REFER TO STRUCTURAL

GENERAL NOTES FOR REFERENCED REPORT.

6. CONTRACTOR MUST COORDINATE WITH THE

FOUNDATION FABRICATION DRAWINGS AND REBAR

SHOP DRAWINGS FOR ALL REQUIRED HOIST

EMBEDDED ITEMS THAT MUST BE CAST IN THE NEW

CONCRETE FOUNDATION.

7. INSTALL MONITORING WELLS AT SAME DEPTH AND

RELATIVE DISTANCE AND ORIENTATION FROM EACH

OTHER AS INSTALLED IN EXISTING CONDITION. FIELD

VERIFY LOCATION WITH NGB.

32.12.01 CONSTRUCT ASPHALT PAVEMENT SECTION PER DETAIL

A13/CS502.

32.13.01 CONSTRUCT CONCRETE PAVEMENT SECTION PER

DETAIL E13/CS502.

32.13.01

32.13.04

32.13.01

32.13.01

32.13.01

BLDG

#1046

BLDG

#1009

BLDG

#1072

32.13.02 CONSTRUCT 5' WIDE CONCRETE SIDEWALK PER DETAIL

A6/CS501.

32.13.02

32.13.03

32.12.02

TYP

TYP

TYP

TYP

TYP

PROPOSED STORMWATER

DETENTION BASIN

PROJECT LIMITS

APPROXIMATE SURVEY LIMITS

EXISTING CONCRETE PAVEMENT

EXISTING ASPHALT PAVEMENT

PROPOSED CONCRETE PAVEMENT

PROPOSED ASPHALT PAVEMENT

PROPOSED AIRFIELD CONCRETE

PAVEMENT

PROPOSED MONITORING WELLS

LOCATION

EXISTING BOLLARD

EXISTING I-BEAM

EXISTING SANITARY SEWER MANHOLE

EXISTING STORM DRAIN MANHOLE

EXISTING FIRE HYDRANT

EXISTING ELECTRICAL MANHOLE

EXISTING HANDHOLE

EXISTING LIGHT POLE

EXISTING COMMUNICATIONS MANHOLE

EXISTING UNKNOWN UTILITY MANHOLE

EXISTING MONITORING WELL

EXISTING TEST HOLE

EXISTING TRAFFIC SIGN

EXISTING TOE OF SLOPE

EXISTING TOP OF BANK

19.67'

0.

106.38'

21.00'

27.74'

115.92'

3.

3.

TY

P.

CONSTRUCT AIRFIELD CONCRETE PAVEMENT SECTION

PER DETAIL J13/CS502.

32.13.04

.3

3'

35.92'

32.12.02 CONSTRUCT BOLLARD PER DETAIL A1/CS501.

PROPOSED EXTERIOR

MECHANICAL YARD

INSTALL HOIST AND HOIST FOUNDATION. SEE NOTES

3-5.32.13.03

PROPOSED MONITORING

WELL LOCATION; SEE

NOTE 7

PROPOSED

TURNOUT AREA

3.00'

TYP.

32.16.06 CONSTRUCT CONCRETE SWALE PER DETAIL K1/CS501.

32.16.06 24.23'

.5

5'

6.95'

32.12.02

TYP

32.12.02

TYP

.4

2'

35.59'

CONTINUATION OF

SEISMIC EXPANSION

JOINT; REFER TO

ARCHITECTURAL

DRAWINGS FOR

ADDITIONAL

INFORMATION

31.00.01 INSTALL RIP RAP APRON PER DETAIL A14/CU503.

31.00.01

32.13.01

32.12.01

TYP

EXPANSION JOINT

NON-EXTRUDING

PREFORMED

COMPRESSIBLE

MATERIAL

1.

TT

5' OR TO NEAREST JOINT

IF JOINT SPACING IS LESS THAN 10'

NEW PCC

NEW OR

EXISTING

PCC

K6

CS501

T = PAVEMENT THICKNESS

T

1.

T

5.00' MINIMUM

5.00' OR TO NEAREST JOINT

IF JOINT SPACING IS LESS THAN 10'-0"

CLEAN SAND AND

COMPACTED SUBGRADE

GRADED, CRUSHED AGGREGATE

ASPHALT PAVEMENT

GRADED, CRUSHED

AGGREGATE

CONCRETE PAVEMENT

JOINT SEALANT

1. REMOVE EXISTING MATERIAL AS NEEDED AND CONSTRUCT IN

ACCORDANCE WITH SPEC SECTIONS 31 00 00

12"

REMOVE EXISTING MATERIAL AS NEEDED

12"

COLD PLANE

COARSE AGGREGATE BASE

CLEAN SAND AND

COMPACTED SUBGRADE

ASPHALT PAVEMENT

EXISTING EDGE OF PAVEMENT;

DIMENSION, OR LOCATION OF

SAWCUT INDICATED ON PLANS

TACK COAT

EXISTING

UNDERLYING

MATERIAL

ACTUAL SAWCUT FULL DEPTH

SAWCUT PARTIAL DEPTH

EXISTING ASPHALT PAVEMENT

1. REMOVE EXISTING MATERIAL AS NEEDED AND CONSTRUCT IN

ACCORDANCE WITH SPEC SECTIONS 31 00 00

EXISTING SUBGRADE

EXISTING CRUSHED

AGGREGATE BASE

EXISTING ASPHALT

PAVEMENT

MATCH EXISTING DEPTH

OF ASPHALT PAVEMENT

SAWCUT AND REMOVE,

(MINIMUM 2" DEPTH)

TACK COAT

2'

JOINT SEALANT

LIMITS OF REMOVAL

SHOWN ON PLANS

T

1.

T

5' OR TO NEAREST JOINT

IF JOINT SPACING IS LESS THAN 10'

NEW CONCRETE PAVEMENT

NEW GRADED, CRUSHED AGGREGATE

NEW CLEAN SAND, AND

COMPACTED SUBGRADE

1. REMOVE EXISTING MATERIAL AS NEEDED AND CONSTRUCT IN

ACCORDANCE WITH SPEC SECTIONS 31 00 00

JOINT SPACING FOR STRAIGHT RUNS

CONTRACTION JOINT SPACING

TRANSVERSE LONGITUDINAL

6' 6' NOT REQUIRED 48' MAX

SAWED CONTRACTION

JOINT W/O BAND (TYP)

MEDIUM BROOM FINISH (TYP)

3" SMOOTH TROWELED BAND

FINISH (TYP)

EXPANSION

JOINT (TYP)

6' (T

YP

U .N

.O

JOINT SEALANT

1W BACKER ROD

PREMOLDED

EXPANSION JOINT

FILLER

1" D

EP

TH

W

AL

K D

EP

TH

1" M

IN

IM

U M

1/8"

MINIMUM

WALK WIDTH

4" PORTLAND CEMENT

CONCRETE (PCC)

4" RIGID PAVEMENT BASE

COURSE (SPEC 32 11 20)

COMPACTED SUBGRADE

(SPEC 31 00 00)COMPACTED SUBGRADE

(SPEC 31 00 00)

SAWED CONTRACTION JOINT

EXPANSION JOINT

4" PORTLAND CEMENT

CONCRETE (PCC)

4" RIGID PAVEMENT BASE COURSE

(SPEC 32 11 20)

3/16"

SIDEWALK BANDED JOINT DETAIL PLAN VIEW

SECTION A-A SECTION B-B

1/8" R

(TYP)

"W" 1/2"

4"

4"

4"

4"

NOTES:

1. SEE SPECIFICATION 32 16 19, CONCRETE CURBS,

GUTTERS AND SIDEWALKS.

1/8" R

(TYP)

WALK

WIDTH

EXPANSION

JOINT

SPACING

B-B

A-A

MAX 1/4" PER FOOT

5' 5' NOT REQUIRED 40' MAX

EXPANSION JOINT

SAWED CONTRACTION JOINT

CONCRETE FOOTING

SLOPE TOP OF FOOTING

AWAY FROM PIPE AS SHOWN

FILL PIPE WITH CONCRETE

ROUND TOP

INSTALL BOLLARD COVER

OVER STEEL BOLLARD

(SEE NOTE 1)

NPS 8" DIA EXTRA

STRONG WEIGHT

STEEL PIPE

6" 3'

-0

4' -0

18"

1. ALL NEW BOLLARDS SHALL HAVE A 52" YELLOW PLASTIC BOLLARD COVER.

2. INSTALL EXPANSION JOINT PER DETAIL K6/CS501 IF BOLLARD ABUTS

PAVEMENT SURFACE.

60'

MINIMUM

T

1.

T

NON-EXTRUDING PREFORMED

COMPRESSIBLE MATERIAL

FIELD MOLDED

SEALANT

BOND BREAKER

TAPE OR BACKER

ROD MATERIAL

SEALANT DEPTH D = W

PER MANUFACTURER

CONCRETE PAVEMENT SURFACE

"W"

4 " (MIN)

6mm BEVEL BY SAWCUT (TYP)1 16

M

IN

1 4" (M

AX

T=PAVEMENT THICKNESS, W=JOINT WIDTH

CONCRETE SWALE

COMPACTED

SUBGRADE

OR BASE

6 x 6 - W1.4 x W1.4 WWF

PAVEMENT

SECTION

TYP

EXPANSION

JOINT

TYP

18" 18"

36"

7"

1:121:12

E13

CS502

K6

CS501

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

CS501

SI

TE

D

ET

AI

LS

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

S5

.d w g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

NEW CONCRETE TO NEW ASPHALT JUNCTUREA14 SCALE: NTS

NEW ASPHALT TO EXISTING ASPHALT JUNCTUREE14 SCALE: NTS

NEW CONCRETE TO EXISTING ASPHALT JUNCTUREK14 SCALE: NTS

THICKENED EDGE ISOLATION JOINTK10 SCALE: NTS

CONCRETE SIDEWALKA6 SCALE: NTS

BOLLARDA1 SCALE: NTS

EXPANSION JOINTK6 SCALE: NTS

CONCRETE SWALEK1 SCALE: NTS

3" 9"

9" COARSE AGGREGATE

BASE (SPEC 32 11 23)

3" ASPHALT PAVEMENT

12" COMPACTED SUBGRADE

TO 95% OF LAB MAXIMUM

PER ASTM D1557

NATURAL SUBGRADE

NOTES:

1. CONSTRUCT IN ACCORDANCE WITH SPEC SECTIONS 31 00 00

AND 32 12 16.16.

2. COARSE AGGREGATE BASE SHALL EXTEND 12 INCHES

BEYOND THE LIMITS OF ASPHALT PAVEMENT

9" 4"

4" RIGID PAVEMENT BASE COURSE

(SPEC 32 11 20)

9" CONCRETE PAVEMENT

(SPEC 32 13 13.06)

NOTES:

1. CONSTRUCT IN ACCORDANCE WITH SPEC SECTIONS 31 00 00, 32 11 20, AND 32 13 13.06.

2. RIGID PAVEMENT BASE COURSE SHALL EXTEND 24 INCHES BEYOND THE LIMITS OF CONCRETE PAVEMENT.

12" SUBGRADE COMPACTED

PER SPECIFICATIONS

NATURAL SUBGRADE

4"

4" RIGID PAVEMENT BASE COURSE

(SPEC 32 11 20)

13.0" CONCRETE PAVEMENT

(SPEC 32 13 14.13)

NOTES:

1. CONSTRUCT IN ACCORDANCE WITH SPEC SECTIONS 31 00 00, 32 11 20, AND 32 13 14.13.

2. RIGID PAVEMENT BASE COURSE SHALL EXTEND 24 INCHES BEYOND THE LIMITS OF CONCRETE PAVEMENT.

12" SUBGRADE COMPACTED

PER SPECIFICATIONS

NATURAL SUBGRADE

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

CS502

SI

TE

D

ET

AI

LS

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

S5

.d w g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

ASPHALT PAVEMENT CONCRETE SECTIONA13 SCALE: NTS

CONCRETE PAVEMENT SECTIONE13 SCALE: NTS

AIRFIELD CONCRETE PAVEMENT SECTIONJ13 SCALE: NTS

S

CB

E

CB

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

S

S

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

26.22

FS

25.74

FS

-1.16%

-1.42%

-0.49%

26.38

FS

25.51

FS

25.21

FS

25.38

FS

24.21

TOG

25.07

FS

24.71

FS

24.38

FS

-0.50%

-0 .6

0%

-0 .5

0%

-0 .5

0% -0

.5 0%

-1.00%

-0 .5

0%

24.54

FS

25.11

FS

25.64

FS

25.49

FS

25.62

FS

25.46

FS

26.07

FS

25.66

FS

25.36

FS

25.31

FS

-2 5.

-25.00%

-25.00%

-25.00%

23.00

FS

20.09

FS

23.00

FS

23.00

FS

23.85

TOG

CB2

FL IN: 21.23

FL OUT: 21.13

25.69

FS RIM ELEV: 25.69

FL IN: 21.07

RIM ELEV: 25.69

FL IN: 21.13

RIM ELEV: 25.69

FL OUT: 20.97

MH1

25.24

FS

RIM ELEV: 25.24

FL IN: 21.35

FL OUT: 21.30MH2

GRADED SWALE

GRADED SWALE

CB1

FL OUT: 21.46

PROPOSED CWF

BLDG

FF = 25.82

FL IN: 19.90

SKIMMER INV: 21.06

FL OUT: 19.00

BOT= 19.70

TOB= 24.26

21 22

18" RCP

18" RCP

18" RCP

18" RCP

18" RCP

24" RCP

24.53

FS

24.85

FS

25.23

FS

24.33

FS

SEE A2/CG201 FOR

SD-4 (POND OUTFALL) PROFILE

SEE H2/CG201 FOR

CB2-MH1-POND SD PROFILE

SEE H2/CG201 FOR

CB2-MH1-POND SD PROFILE

SEE H7/CG201 FOR

CB1-MH2-MH1 SD PROFILE

SEE H14/CG201 FOR

EXISTING CB-MH2 SD PROFILE

SEE H7/CG201 FOR

CB1-MH2-MH1 SD PROFILE

SEE A7/CG201 FOR

ROOF DRAINAGE SD PROFILE

12" RCP

PLAN

NORTH

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

LEGEND

CWF

CG101

G R

AD

IN

G P

LA

N

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

G

1.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

GRADING PLANA4 SCALE: 1" = 30'

SHEET NOTES

1. REFER TO SHEET C-001 FOR LEGEND AND

ABBREVIATION AND SHEET C-002 FOR GENERAL

NOTES.

2. EXISTING CONDITIONS OUTSIDE OF APPROXIMATE

SURVEY LIMITS WERE PROVIDED FROM

SUPPLEMENTAL INFORMATION. VERIFY ALL EXISTING

CONDITIONS PRIOR TO CONSTRUCTION.

3. ALL FINISHED SURFACE (FS) SPOT ELEVATIONS

DENOTED WITH AN ASTERISK (FS*) ARE TO MATCH

EXISTING GRADE.

4. REFER TO CG201 FOR STORM DRAIN PROFILES.

5. REFER TO ARCHITECTURAL DRAWINGS FOR EGRESS

DOOR STOOP REQUIREMENTS.

PROJECT LIMITS

EXISTING LANDSCAPE

EXISTING CONCRETE PAVEMENT

EXISTING ASPHALT PAVEMENT

PROPOSED CONCRETE

PAVEMENT

PROPOSED ASPHALT PAVEMENT

PROPOSED AIRFIELD CONCRETE

PAVEMENT

PROPOSED STORM DRAIN LINE

PROPOSED CATCH BASIN

SPOT ELEVATION

FLOW DIRECTION ARROW

EXISTING TOP OF BANK

EXISTING TOE OF SLOPE

EXISTING I-BEAM

EXISTING FENCE

CB

26.63

30'0'30'

GRAPHIC SCALE

FS

KEYNOTES

33.11.01

PLAN

NORTH

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

LEGEND

PROJECT LIMITS

EXISTING LANDSCAPE

EXISTING CONCRETE PAVEMENT

EXISTING ASPHALT PAVEMENT

PROPOSED CONCRETE

PAVEMENT

PROPOSED ASPHALT PAVEMENT

TEMPORARY CONSTRUCTION

ENTRANCE

FIBER ROLL

SILT FENCE

INLET PROTECTION

CONCRETE WASHOUT AREA

LIMITS

STOCKPILE AND STORAGE AREA

EXISTING CATCH BASINCB

CWF

CG121

ER

O

SI

O

N A

N D

S

ED

IM

EN

T C

O N

TR

O

L

PL

AN

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

G

1.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

EROSION AND SEDIMENT CONTROL PLANA4 SCALE: 1" = 30'

SHEET NOTES

KEYNOTES

30'0'30'

1. REFER TO SHEET C-001 FOR LEGEND AND

ABBREVIATION AND SHEET C-002 FOR GENERAL

NOTES.

2. EXISTING CONDITIONS OUTSIDE OF APPROXIMATE

SURVEY LIMITS WERE PROVIDED FROM

SUPPLEMENTAL INFORMATION. VERIFY ALL EXISTING

CONDITIONS PRIOR TO CONSTRUCTION.

3. STOCKPILE AND STORAGE AREA LOCATIONS TO BE

VERIFIED WITH THE SITE PRIOR TO CONSTRUCTION.

4. REFER TO DETAIL A14/CG502 AND DETAIL G14/CG502

FOR MATERIAL STORAGE AREA AND VEHICLE

MAINTENANCE AND STORAGE AREA.

31.25.01 INSTALL TEMPORARY CONSTRUCTION ENTRANCE PER

DETAIL F1/CG501.

31.25.01

31.25.02 INSTALL SILT FENCE PER DETAIL A16/CG501.

PROPOSED

HOIST

EXISTING

OIL/WATER

SEPARATOR

PROPOSED STORMWATER

DETENTION BASIN

31.25.03 INSTALL FIBER ROLL PER DETAIL A1/CG501.

31.25.04 INSTALL INLET PROTECTION PER DETAIL A5/CG501.

31.25.05 GENERAL LOCATION FOR CONCRETE WASHOUT.

INSTALL CONCRETE WASHOUT AREA PER DETAIL

F7/CG501.

31.25.06 STOCKPILE AND STORAGE AREA, REFER TO GENERAL

NOTE 3.

31.25.06

31.25.05 31.25.04

31.25.01

9+75 10+00 11+00 11+76

18" RCP

GRADE = 0.20%

24" RCP

GRADE = 0.20%

EXISTING GROUND

PROPOSED GRADE

C

B2

ST

A:

0+

.4

R

IM

: 2 3.

IN

V.

IN

: 2 1.

IN

V.

O

U T:

1.

M H

ST

A:

1+

.8

R

IM

: 2 5.

IN

V.

IN

: 2 0.

IN

V.

IN

: 2 1.

IN

V.

O

U T:

0.

81.35' 74.33'

10+00 11+00 11+92

EXISTING GROUND

PROPOSED GRADE

C B1

ST

A:

0+

.0

R

IM

: 2

4.

IN

V.

O U

T:

1.

18" RCP

GRADE = 0.20% 18" RCP

GRADE = 0.20%

M H

ST

A:

0+

.8

R

IM

: 2 5.

IN

V.

IN

: 2 1.

IN

V.

IN

: 2 1.

IN

V.

O

U T:

1.

M H

ST

A:

1+

.8

R

IM

: 2 5.

IN

V.

IN

: 2 0.

IN

V.

IN

: 2 1.

IN

V.

O

U T:

0.

34.76' 140.16'

9+75 10+00 10+47

EXISTING GROUND

PROPOSED GRADE

18" RCP

GRADE = 0.20%

M H

ST

A:

0+

.8

R

IM

: 2 5.

IN

V.

IN

: 2 1.

IN

V.

IN

: 2 1.

IN

V.

O

U T:

1.

38.29'

9+75 10+00 10+60

EXISTING GROUND

PROPOSED GRADE

18" RCP

GRADE = 2.87%

ST

A.

0+

.5

S

KI

M

M

ER

W

EI

R

IN

V

EL

EV

. 2

1.

EL

. 1

9.

ST

A.

0+

.8

H

EA

D

W

AL

L

EL

. 1 9.

31.38'

9+75 10+00 11+00 12+00 12+75

C B2

ST

A:

0+

.4

R

IM

: 2

3.

IN

V.

IN

: 2

1.

IN

V.

O U

T:

1.

12" RCP

GRADE = 0.68%

12" RCP

GRADE = 0.68%

EXISTING GROUND PROPOSED GRADE

PA

R

SO

N

S G

O

VE

R N

M

EN

T

SE

R

VI

C

ES

IN

C

W

ES

T

W

AL

N U

T

ST

R

EE

T

6)

-2

PA

SA

D

EN

A

C

AL

IF

O

R N

IA

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

TA

SK

O R

D

ER

N O

D

AT

E M

AR

K

D

ES

C R

IP

TI

O N

NOT FOR

CONSTRUCTION

FI

LE

N

AM

E:

1 3 5 7 9 11 13 15 17 192 4 6 8 10 12 14 16 18 20

N

L

J

G

E

C

A

P

M

K

H

F

D

B

THIS ITEM HAS BEEN DIGITALLY SIGNED AND

SEALED BY ON THE

DATE ADJACENT TO THE SEAL.

PRINTED COPIES OF THIS DOCUMENT ARE

NOT CONSIDERED SIGNED AND SEALED AND

THE SIGNATURE MUST BE VERIFIED ON ANY

ELECTRONIC COPIES.

JA

C

KS

O

N

VI

LL

E

AI

R

N

AT

IO

N

AL

G

U

AR

D

FI

R

ST

T

IT

LE

SHEET ID

CWF

CG201

ST

O

R M

D R

AI

N

P R

O

FI

LE

S

J.

C

H O

U

J.

C

H O

U

J.

A

ZA

D

S.

G

EO

R

G E

JA

X-

AN

G

-C -C

G

1.

dw g

AN

SI

D x3

FA

-2

1- D

-0

W

S6 Y2

4F

JA

N

U

AR

Y

F-

C

O N

SO

LI

D

AT

ED

W

EA

PO

N S

FA

C

IL

IT

Y

JA

C

KS

O N

VI

LL

E, F

LO

R

ID

A

B-3 100% DESIGN SUBMITTAL

CB2-MH1-POND SD PROFILEH2 HOR SCALE: 1" = 30'

VER SCALE: 1" = 3'

SHEET NOTES

1. REFER TO SHEET C-001 FOR LEGEND AND

ABBREVIATIONS AND SHEET C-002 FOR GENERAL

NOTES.

CB1-MH2-MH1 SD PROFILEH7 HOR SCALE: 1" = 30'

VER SCALE: 1" = 3'

EXISTING CB-MH2 SD PROFILEH14 HOR SCALE: 1" = 30'

VER SCALE: 1" = 3'

SD-4 (POND-OUTFALL) PROFILEA2 HOR SCALE: 1" = 30'

VER SCALE: 1" = 3'

SD-5 (ROOF DRAINAGE) PROFILEA2 HOR SCALE: 1" = 30'

VER SCALE: 1" = 3'

" M

IN

PONDING HEIGHT

RUNOFF

SILT FENCE FABRIC SHOULD CONFORM TO THE AASHTO M288 96 SILT FENCE

SPECIFICATION. THE POSTS USED TO SUPPORT THE SILT FENCE FABRIC SHOULD BE

A HARDWOOD MATERIAL WITH THE FOLLOWING MINIMUM DIMENSIONS: 2" SQUARE

(NOMINAL) BY 4.5' LONG. SILT FENCE FABRIC SHOULD BE ATTACHED TO THE

WOODEN POSTS WITH STAPLES, WIRE, ZIP TIES, OR NAILS.

A SLOPE BARRIER SHOULD BE USED AT THE TOE OF A SLOPE WHEN A DITCH DOES

NOT EXIST. THE SLOPE BARRIER SHOULD BE PLACED ON NEARLY LEVEL GROUND 5'

TO 10' AWAY FROM THE TOE OF A SLOPE. THE BARRIER IS PLACED AWAY FROM THE

TOE OF THE SLOPE TO PROVIDE ADEQUATE STORAGE FOR SETTLING OUT

SEDIMENT. WHEN PRACTICABLE, SILT FENCE SLOPE BARRIERS SHOULD BE PLACED

ALONG CONTOURS TO AVOID A CONCENTRATION OF FLOW. SILT FENCE SLOPE

BARRIERS CAN ALSO BE PLACED ALONG RIGHT-OF-WAY FENCE LINES TO KEEP

SEDIMENT FROM CROSSING ONTO ADJACENT PROPERTY. WHEN PLACED IN THIS

MANNER, THE SLOPE BARRIER WILL NOT LIKELY FOLLOW CONTOURS.

WOOD POST

36" HIGH MAX.

FILTER FABRIC ATTACH

SECURELY TO UPSTREAM

SIDE OF POST

4" X 6" TRENCH WITH

COMPACTED BACKFILL

EXCAVATE A TRENCH THE LENGTH OF THE PLANNED SLOPE BARRIER THAT IS 6"

DEEP BY 4" WIDE. MAKE SURE THAT THE TRENCH IS EXCAVATED ALONG A SINGLE

CONTOUR. WHEN PRACTICABLE, SLOPE BARRIERS SHOULD BE PLACED ALONG

CONTOURS TO AVOID A CONCENTRATION OF FLOW. PLACE THE SOIL ON THE

UPSLOPE SIDE OF THE TRENCH FOR LATER USE. ROLL OUT A CONTINUOUS LENGTH

OF SILT FENCE FABRIC ON THE DOWNSLOPE SIDE OF THE TRENCH. PLACE THE EDGE

OF THE FABRIC IN THE TRENCH STARTING AT THE TOP UPSLOPE EDGE. LINE ALL

THREE SIDES OF THE TRENCH WITH THE FABRIC. BACKFILL OVER THE FABRIC IN THE

TRENCH WITH THE EXCAVATED SOIL AND COMPACT. AFTER FILLING THE TRENCH,

APPROXIMATELY 24" TO 36" OF SILT-FENCE FABRIC SHOULD REMAIN EXPOSED. LAY

THE EXPOSED SILT FENCE UPSLOPE OF THE TRENCH TO CLEAR AN AREA FOR

DRIVING IN THE POSTS. JUST DOWNSLOPE OF THE TRENCH, DRIVE POSTS INTO THE

GROUND TO A DEPTH OF AT LEAST 18". PLACE POSTS NO MORE THAN 4' APART.

ATTACH THE SILT FENCE TO THE ANCHORED POST WITH STAPLES, WIRE, ZIP TIES,

OR NAILS.

WHEN PRACTICABLE, DO NOT PLACE SILT FENCE SLOPE BARRIERS ACROSS

CONTOURS. SLOPE BARRIERS SHOULD BE PLACED ALONG CONTOURS TO AVOID A

CONCENTRATION OF FLOW. WHEN THE FLOW CONCENTRATES, IT OVERTOPS THE

BARRIER AND THE SILT FENCE SLOPE BARRIER QUICKLY DETERIORATES. DO NOT

PLACE SILT-FENCE POSTS ON THE UPSLOPE SIDE OF THE SILT FENCE FABRIC. IN

THIS CONFIGURATION, THE FORCE OF THE WATER IS NOT RESTRICTED BY THE

POSTS, BUT ONLY BY THE STAPLES (WIRE, ZIP TIES, NAILS, ETC.). THE SILT FENCE

WILL RIP AND FAIL.