Asbestos -Lead Paint Survey-Terracon.pdf
PDF 1 MB Posted
- Attached to
- F-35 CONSTRUCT COMBINED WEAPONS FACILITY Federal contract opportunity
- Solicitation number
- W50S6Y-25-B-A004
About this file
This is an asbestos and lead paint survey report prepared by Terracon Consultants for Parsons Corporation, documenting testing conducted on December 21, 2023 at Building 1022 (Recreation Room) at 1400 FANG Drive in Jacksonville, Florida. The survey was performed as part of pre-demolition assessment requirements for a new F-35 Combined Weapons Facility construction project.
The report details that no asbestos was identified in any of the 36 bulk samples collected from 12 homogeneous areas throughout the building, including ceiling tiles, carpet glue, concrete, vinyl base, duct mastic, batt paper, window caulk, drywall systems, and other materials. Lead testing identified detectable levels of lead (0.010% by weight) in one of two paint samples - specifically in the beige paint on exterior concrete walls, while interior drywall paint contained less than 0.016% lead by weight. The report recommends that contractors performing work comply with OSHA Lead in Construction standard 29 CFR 1926.62 when disturbing the lead-containing exterior paint, which was noted to be in generally good condition with some small areas of peeling.
View the file
Other files for this federal contract opportunity
Show all 36
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Asbestos and Lead
Paint Survey Report
Recreation Room
Building 1022
Jacksonville, Florida 32218
Terracon Project EQ237421
Prepared for:
Parsons Corporation
6100 Bandera Rd
San Antonio, TX
Prepared by:
Terracon Consultants, Inc.
Jacksonville, FL
8001 Baymeadows Way Suite 1
Jacksonville, Florida 32256
P 904-900-6494
TERRACON.COM
January 5, 2024
6100 Bandera Rd
Suite 800
San Antonio, TX 78238
Attn: David Pratt
Phone: 210-805-2286
Cell: 210-347-8775
Email: David.Pratt@Parsons.com
Re: Asbestos and Lead Survey Report
Recreation Room, Building 1022
1400 FANG Drive
Terracon Project EQ237421
Dear Mr. Pratt:
The purpose of this report is to present the results of an Asbestos and Lead Paint Survey at the above-referenced site. The asbestos and lead surveys were limited to readily accessible materials.
Terracon performed the surveys on December 21, 2023. The asbestos survey and lead paint survey was conducted in general accordance with our proposal dated September 22, 2023.
• Asbestos was not identified in samples obtained from the structure
• Lead was identified in one sample of paint obtained from the structure
Please see the attached report for details.
Terracon appreciates the opportunity to provide this service to Parsons Cororation. (client). If you have any questions regarding this report, please contact Mr. Peter Thompson at 904-330-4405.
Sincerely, Terracon Consultants, Inc.
Florida Asbestos Consulting Business License No. ZA337
Peter Thompson Michael W. Schrum, P.E.
Senior Staff Scientist Florida Licensed Asbestos Consultant
AHERA Certified Building Inspector License # AX78
Certificate # 240081-1896 Authorized Project Reviewer
TABLE OF CONTENTS
1.0 INTRODUCTION
1.1 Project Objective
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES
3.1 Asbestos Survey
3.2 Visual Assessment
3.3 Physical Assessment
3.4 Sample Collection and Analysis
3.5 Lead in Paint Survey
3.6 Sample Collection
3.7 Sample Analysis
4.0 REGULATORY OVERVIEW
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos Survey Findings
5.2 Asbestos Recommendations
5.3 Paint Containing Lead Survey Findings
5.4 Lead Recommendations
6.0 LIMITATIONS/GENERAL COMMENTS
LIST OF APPENDICES
APPENDIX A ASBESTOS SAMPLE SUMMARY
APPENDIX B ASBESTOS LABORATORY ANALYTICAL DATA
APPENDIX C LEAD SAMPLE SUMMARY
APPENDIX D LEAD LABORATORY ANALYTICAL DATA
APPENDIX E CERTIFICATIONS, ACCREDITATIONS, AND LICENSES
APPENDIX F PHOTOGRAPHS
Asbestos and Lead Paint Survey Report Recreation Room, Building 1022 | FANG Drive | Jacksonville, Florida January 5, 2024 | Terracon Project EQ237421
Environmental | Facilities | Geotechnical | Materials 1
1.0 INTRODUCTION
Terracon Consultants, Inc. (Terracon) conducted an asbestos survey and a lead paint survey at the above-referenced structure. Terracon performed the surveys on December 21, 2023. Asbestos and lead surveys were limited to readily accessible materials.
The asbestos survey activities were conducted by Mr. Pete Thompson, an Asbestos Hazard Emergency
Response Act (AHERA)-accredited building inspector. The lead paint survey was conducted by Mr.
Thompson. Mr. Thompson is an EPA-certified lead paint inspector. Copies of Mr. Thompson’s asbestos inspector training certificate and EPA Lead Inspector certificate can be found in Appendix E.
The surveys were conducted in general accordance with our proposal dated September 22, 2023.
Interior and exterior components including the roof were surveyed, and homogeneous areas of suspect asbestos-containing materials (ACM) and paint and other coatings (PCL) were visually identified and documented prior to sampling.
Although reasonable effort was made to survey accessible suspect materials, additional suspect but unsampled materials could be located in walls, in voids or in other concealed areas.
1.1 Project Objective
Terracon understands the purpose of these surveys was to provide information to the client regarding asbestos and lead content in materials prior to demolition of the structure. EPA regulation 40 CFR 61, Subpart M, NESHAP, prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities. The asbestos NESHAP requires that potentially regulated asbestos-containing building materials be identified, classified, and quantified prior to planned disturbances or demolition activities. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA AHERA regulation, 40 CFR 763.86.
The OSHA lead standard for construction (29 CFR 1926.62) applies to construction work where an employee may be occupationally exposed to lead. Work related to construction, alteration, or repair
(including painting and decorating) is included. The lead standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions.
Unique paint combinations were identified and sampled for laboratory analysis to identify the presence of lead in building components that may be impacted by any planned disturbance.
2.0 BUILDING DESCRIPTION
The site is a one-story structure which is referred to by site personnel as the recreation building. The structure contains a space reserved as an office and eating and limited food preparation areas. The roof consists of a high slope standing seam metal roof. Typical building components encountered in the structure consisted of drywall walls, drop-in ceiling tiles, vinyl floor tiles, and carpets. The building construction date is unknown but appears in aerial photographs dated 1978 and was in use at the time of the surveys.
3.0 FIELD ACTIVITIES
3.1 Asbestos Survey
The survey was conducted in general accordance with the sample collection protocols established in
EPA regulation AHERA, 40 CFR 763.86. Our survey activities began with visual observation of the building components to identify apparent homogeneous areas of suspect ACM. A homogeneous area
January 5, 2024 | Terracon Project EQ237421
Environmental | Facilities | Geotechnical | Materials 2 consists of building materials that appear similar throughout in terms of color, texture, and date of application. The assessment was conducted throughout physically accessible areas of the structure.
Terracon lifted floor coverings in several locations to check for the presence of concealed suspect materials. Building materials identified as glass, wood, metal, and rubber are not considered suspect
ACM.
3.2 Visual Assessment
Survey activities were initiated with visual observation of the interior and exterior of the building to identify accessible homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of installation.
3.3 Physical Assessment
A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.
3.4 Sample Collection and Analysis
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols from areas accessible to our inspector. Random samples of suspect materials were collected from each homogeneous area. Samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
Bulk asbestos samples were submitted under chain of custody to Cates Labs (Cates) of Dallas, Texas for analysis by Polarized Light Microscopy with dispersion staining techniques (PLM) per USEPA methodology EPA 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Cates is accredited under the National Voluntary Laboratory
Accreditation Program (NVLAP) Accreditation # 200569-0. The laboratory was instructed to analyze all samples from each homogeneous area. A total of 36 bulk samples from the structure were collected from 12 homogeneous areas (HAs) of suspect ACM from the site.
3.5 Lead in Paint Survey
Terracon performed a visual assessment to identify suspect paint containing lead and document the general location of the materials and the condition of the materials, including noting areas of damaged, peeling, or flaking paint. Terracon collected representative paint chip samples of suspect coatings identified on surfaces in the building. Samples of paint were collected to the visible substrate e.g., wood, metal, masonry, etc. A summary of LCP sampling activities is provided below.
3.6 Sample Collection
Terracon collected two suspect paint chip samples from identified testing combinations within the structure. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
January 5, 2024 | Terracon Project EQ237421
Environmental | Facilities | Geotechnical | Materials 3
3.7 Sample Analysis
Paint sampling included visual observations of coated surfaces (i.e., paints, varnishes) to identify potential PCL-coated components and to collect bulk samples. Samples were submitted under chain of custody to EMSL Analytical of Orlando Florida for analysis by EPA Method SW-846 7000B Flame Atomic
Absorption Spectrophotometry. EMSL is accredited by the AIHA® Laboratory Accreditation Programs, LLC under the Environmental Lead Laboratory Accreditation Program (ELLAP).
4.0 REGULATORY OVERVIEW
Asbestos
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. It also requires the identification and classification of existing building materials prior to demolition or renovation activity. Under NESHAP, asbestos-containing building materials are classified as either friable, Category I non-friable or Category II non-friable ACM. Friable materials are those that, when dry, may be crumbled, pulverized or reduced to powder by hand pressure. Category I non-friable ACM includes packings, gaskets, resilient floor coverings and asphalt roofing products containing more than 1% asbestos. Category II non-friable ACM are any materials other than Category I materials that contain more than 1% asbestos.
Friable ACM, Category I and Category II non-friable ACM which is in poor condition and has become friable or which will be subjected to drilling, sanding, grinding, cutting or abrading and which could be crushed or pulverized during anticipated renovation or demolition activities are considered regulated
ACM (RACM).
In the State of Florida, asbestos activities are regulated by the Florida Department of Environmental
Protection (FDEP). RACM must be removed prior to renovation or demolition activities which will disturb the materials. The owner or operator must provide the FDEP with written notification of asbestos abatement activities and/or planned demolition activities at least 10 working days prior to the commencement of such activities.
The U.S. Occupational Safety and Health Administration (OSHA) Asbestos standard for construction
(29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers be maintained at or below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed 1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL).
The TWA and EL are known as OSHA’s permissible exposure limits (PELs). The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own federally approved state OSHA programs may require additional precautions.
Lead Containing Paint
Lead in paint is regulated by the EPA and OSHA. EPA regulates lead use, removal, and disposal and
OSHA regulates worker exposure to lead. The OSHA lead standard definition includes metallic lead, all inorganic lead compounds, organic lead soaps, paints and coatings with detectable lead concentrations.
The EPA regulates disposal of hazardous materials. The EPA has stated that components removed with intact LBP that is not delaminating from the substrate may be disposed as general demolition debris.
If the LBP is stripped from components, or if it is delaminating from the substrate, the waste may be subject to hazardous waste rules such as Toxicity Characteristics Leaching Procedure (TCLP).
January 5, 2024 | Terracon Project EQ237421
Environmental | Facilities | Geotechnical | Materials 4
The OSHA lead standard for construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair
(including painting and decorating) is included. The lead standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions.
Under this standard, construction includes, but is not limited to, the following:
• Demolition or salvage of structures where lead or materials containing lead are present
• Removal or encapsulation of materials containing lead
• New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead
• Installation of products containing lead
• Lead contamination/emergency clean-up
• Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed
• Maintenance operations associated with construction activities described above
Employers must ensure that no employee will be exposed to lead at concentrations greater than the
PEL of 50 micrograms per cubic meter (mg/m3) as an 8-hr TWA without adequate protection. The
OSHA standard also establishes an action level of 30 mg/m3, which if exceeded, triggers certain requirements, including periodic exposure monitoring and medical monitoring.
5.0 FINDINGS AND RECOMMENDATIONS
5.1 Asbestos Survey Findings
Asbestos was not identified in samples obtained from the structure. Identified homogeneous areas of sampled suspect materials are listed in Appendix A. The asbestos laboratory analytical report and chain-of-custody are provided in Appendix B.
5.2 Asbestos Recommendations
Materials not included in this limited survey may be revealed during the course of future renovation or demolition activities. These materials should be assumed to be asbestos-containing and removed as asbestos-containing materials or should be sampled and submitted for laboratory analysis in order to determine their asbestos content before any further activities that may disturb them.
5.3 Lead Containing Paint Survey Findings
Detectable levels of lead were identified in one sample of the two paints collected as part of this survey. Please refer to Table 2 below. The laboratory analytical report and chain of custody are provided in Appendix A.
Table 2
Sample ID Color / Substrate Sample Location Lead Content
2 Beige / Concrete Exterior wall surface 0.010% wt.
5.4 Lead Recommendations
The identified lead-containing beige paint coating was in good condition with some small areas of peeling at the time of our survey. Care should be taken not to cause the painted surfaces to be disturbed by personnel.
January 5, 2024 | Terracon Project EQ237421
Environmental | Facilities | Geotechnical | Materials 5
Terracon recommends that contractors performing work in these locations be made aware of the results of this survey. Contractors must comply with the OSHA Lead in Construction standard 29 CFR
1926.62 when disturbing paints or coatings with detectable concentrations of lead.
The painting history of any given location in an older building often will vary from point to point due to such factors as variability in paints used, paint film thickness, variable retention of older paint layers before repainting, demolition/installation of walls during renovations, and unknown historic non-homogenous painting schemes. As such, a given color and building component combination that is apparent to our inspector may not provide consistent testing results for lead. Paints forming a lower, concealed layer which were not collected for sampling may be present and may contain detectable levels of lead. These materials, if present should be considered to be lead-containing and should be sampled and submitted for laboratory analysis in order to determine their lead content before any further activities that may disturb them.
6.0 LIMITATIONS/GENERAL COMMENTS
This asbestos and lead surveys were conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. If other suspect materials or conditions are encountered, please contact Terracon for proper evaluation and interpretations. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our surveys of the building. The information contained in this report is relevant to the date on which these surveys were performed and should not be relied upon to represent conditions at a later date.
This report has been prepared on behalf of and exclusively for use by the client for specific application to their project as discussed. All quantities are estimated. This report is not a bidding document.
Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
ASBESTOS SAMPLE SUMMARY
HA Material Description Location Friable Quantity of ACM
1 Light gray ridged 2' x 2' drop-in ceiling tiles Throughout entire building NA -
2 Yellow carpet glue Throughout NA -
3 Light gray concrete Transformer curb in AC room NA -
4 Light gray concrete Slab NA -
Light gray 4 inch vinyl cove base and associated gray adhesive
Base of perimeter and internal walls throughout
NA -
6 Off-white duct mastic AC closet NA -
7 Black batt paper Interstitial ceiling space NA -
8 Dark brown window, door caulk Glass door, small window in office
NA -
9 Off-white drywall system with finish coat Perimeter and internal walls NA -
10 Gray concrete block and mortar Exterior perimeter walls NA -
11 Dark brown window caulk Exterior windows NA -
12 Gray joint caulk East wall NA -
NA = Not Applicable
APPENDIX B
ASBESTOS LABORATORY ANALYSIS
PLM REPORT SUMMARY
Cates Laboratories NVLAP Lab No. 200569-0
1339 Motor Circle TDSHS License No. 30-0287 Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-35802 Project (Line 1): Limited Asbestos Inspection Set No.: 51264 Project (Line 2): 14300 Fang Drive, Jacksonville, FL Report Date: 1/4/2024 Project No: EQ237421 Sample Date: 12/21/2023 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS) EPA Method 600/R-93/116 Page 1 of 4
On 12/22/2023, thirty-six (36) bulk samples were submitted by Mr. Pete Thompson of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Lab
Sample No.
Client
Field I.D.
Sample Description/Location Asbestos Content
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced except in full.
CL1214436
1A
Light Grey Ridged 2 X 2 Drop-In Ceiling Tiles - Entrance Door
None Detected
CL1214437
1B
Light Grey Ridged 2 X 2 Drop-In Ceiling Tiles - AC Closet
CL1214438
1C
Light Grey Ridged 2 X 2 Drop-In Ceiling Tiles - Office
CL1214439
2A
Yellow Carpet Glue - Front Door
CL1214440
2B
Yellow Carpet Glue - Emergency Door
CL1214441
2C
Yellow Carpet Glue - Glass Door
CL1214442
3A
Light Grey Concrete - Curb
CL1214443
3B
CL1214444
3C
CL1214445
4A
Light Grey Concrete - Glass Door
None Detected - Paint Layer None Detected - Concrete
CL1214446
4B
Light Grey Concrete - Entrance Door
CL1214447
4C
Light Grey Concrete - Emergency Door
CL1214448
5A
Light Grey 4" Vinyl Cove Base & associated Grey adhesive - AC Closet
None Detected - Cove Base None Detected - Cream Mastic
CL1214449
5B
Light Grey 4" Vinyl Cove Base & associated Grey adhesive - Entrance Door
CL1214450
5C
Light Grey 4" Vinyl Cove Base & associated Grey adhesive - Glass Door
CL1214451
6A
Off-White Duct Mastic - AC Duct
CL1214452
6B
CL1214453
6C
1339 Motor Circle TDSHS License No. 30-0287 Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-35802 Project (Line 1): Limited Asbestos Inspection Set No.: 51264 Project (Line 2): 14300 Fang Drive, Jacksonville, FL Report Date: 1/4/2024 Project No: EQ237421 Sample Date: 12/21/2023 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS) EPA Method 600/R-93/116 Page 2 of 4
On 12/22/2023, thirty-six (36) bulk samples were submitted by Mr. Pete Thompson of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL1214454
7A
Black Batt Paper - ICS North
None Detected - Paper/Mastic None Detected - Insulation
CL1214455
7B
Black Batt Paper - ICS South
CL1214456
7C
Black Batt Paper - ICS Center
CL1214457
8A
Dark Brown Window, Door Caulk - Glass Door
CL1214458
8B
Dark Brown Window, Door Caulk - Glass Door
CL1214459
8C
Dark Brown Window, Door Caulk - Small Window
CL1214460
9A
Off-White Drywall System w/Finish Coat - ICS
None Detected - Finish Coat None Detected - Paper None Detected - Wallboard Material
CL1214461
9B
CL1214462
9C
CL1214463
10A
Grey Concrete Block & Mortar - Northwest Corner
None Detected - Filler/Texture None Detected - CMU Block None Detected - Mortar
CL1214464
10B
Grey Concrete Block & Mortar - Northeast Corner
CL1214465
10C
Grey Concrete Block & Mortar - Southwest Corner
CL1214466
11A
Dark Brown Window Caulk - Glass Door
1339 Motor Circle TDSHS License No. 30-0287 Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-35802 Project (Line 1): Limited Asbestos Inspection Set No.: 51264 Project (Line 2): 14300 Fang Drive, Jacksonville, FL Report Date: 1/4/2024 Project No: EQ237421 Sample Date: 12/21/2023 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS) EPA Method 600/R-93/116 Page 3 of 4
On 12/22/2023, thirty-six (36) bulk samples were submitted by Mr. Pete Thompson of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below:
Client
These samples were analyzed by layers. The overall percent asbestos for the sample is reported when relevant. The EPA considers a material to be asbestos containing only if it contains greater than one percent asbestos by Calibrated Visual Area Estimation (CVAE). EPA regulations also indicate that Regulated Asbestos Containing Materials (RACM) – materials that are friable or may become friable – be further analyzed by point counting when the results indicate less than ten percent asbestos by CVAE. CatesLab utilizes CVAE on a routine basis and does not include point counting unless specifically requested by the client. The results may not be reproduced
CL1214467
11B
Dark Brown Window Caulk - West Side Window
CL1214468
11C
Dark Brown Window Caulk - North Side Window
CL1214469
12A
Grey Joint Caulk - East Wall Joint
CL1214470
12B
CL1214471
12C
1339 Motor Circle TDSHS License No. 30-0287 Dallas, Texas 75207 (214) 920-5006
Client: Terracon Lab Job No.: PLM-35802 Project (Line 1): Limited Asbestos Inspection Set No.: 51264 Project (Line 2): 14300 Fang Drive, Jacksonville, FL Report Date: 1/4/2024 Project No: EQ237421 Sample Date: 12/21/2023 Identification: Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy/Dispersion Staining (PLM/DS)
EPA Method 600/R-93/116 Page 4 of 4
On 12/22/2023, thirty-six (36) bulk samples were submitted by Mr. Pete Thompson of Terracon for asbestos analysis by PLM/DS.
Copies of the lab data sheets are attached; additional information may be found therein.
STATEMENT OF LABORATORY ACCREDITATION
The samples were analyzed in general accordance with the procedures outlined in the U.S. EPA Interim Method for the Determination of Asbestos in Bulk Insulation Samples as found in 40 CFR, Part 763, Subpart E, Appendix E (formerly Subpart F, Appendix A), or the current U.S. EPA method (EPA Method 600/R-93/116) for the analysis of asbestos in building materials, by polarized light microscopy. The results of each bulk sample relate only to the material tested and the results shall not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government.
Specific questions concerning bulk sample results shall be directed to the Laboratory Director.
Analyst:
Kathy Schosek
Laboratory Director: John R. Cates, P.G.
Approved Signatory:
TESTING
NVLAP LAB CODE 200569-0
APPENDIX C
LEAD SAMPLE SURVEY SUMMARY
Identified Lead Paint Testing Combinations
Sample
ID
Color / Substrate Locations Lead Content
1 Beige / Drywall Interior walls <0.0160 % wt.
2 Beige / Concrete Exterior walls 0.0100 % wt.
APPENDIX D
LEAD LABORATORY ANALYSIS
OrderID: 342328439
Client Sample Description ConcentrationLab ID Analyzed Weight Lead
Collected
EMSL Analytical, Inc.
3303 PARKWAY CENTER COURT, Orlando, FL 32808 Phone/Fax: (407) 599-5887 / (407) 599-9063 http://www.EMSL.com orlandolab@emsl.com
Attn: Pete Thompson Terracon Consultants, Inc.
8001 Baymeadows Way, Suite 1 Jacksonville, FL 32256
Received: 12/22/2023 10:24 AM
EQ237421
Fax:
Phone: (904) 419-7055
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
342328439 CustomerID: TRCF34 CustomerPO: EQ237421 ProjectID:
EMSL Order:
0.1264 Site: Drywall / Interior, Beige 342328439-00011 <0.016 % wt12/26/2023 g
0.3135 Site: Concrete / Walls + Slab, Beige 342328439-00022 0.010 % wt12/26/2023 g
Heather Ohye, Metals Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 12/28/2023 4:21:13 PM
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
* Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Orlando, FL AIHA LAP, LLC-ELLAP Accredited #163563
Initial report from 12/28/2023 16:21:13 http://www.EMSL.com mailto:orlandolab@emsl.com
File details come from the government source that posted it. Updated .