SYRING SE-T101-ARCH C.pdf
PDF 220 KB Posted
- Attached to
- 2025 E-Rate Network Cabling Additions
- Solicitation number
- RFP-SCC-250000001194-2
- Issued by
- Michigan
About this file
This is a structured cabling system floor plan and technical specifications document for Syring Elementary School in the Swartz Creek Community Schools district, created by Convergent Technology Partners. The drawing details the installation requirements for Category 6A UTP cabling throughout the school building, including wall and ceiling mounting locations, telecom cabinets, and bus-bars. The design document is dated January 27, 2025, with an earlier design version from December 17, 2024.
The technical specifications require all UTP cable to be ANSI/TIA Category 6A standard, installed in surface-mounted single-gang back boxes with white two-port faceplates. Installation requirements include concealed raceway cabling below ceiling, service loops for ceiling locations, white 8P/8C (RJ45) jack terminations, and specific mounting heights relative to whiteboards. The floor plan shows multiple UTP locations throughout the building, telecom cabinet placements, and bus-bar locations, with all cabinets requiring grounding per the general notes.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TGB
SYMBOL LEGEND
UTP LOCATION, QTY AS
NOTED
CEILING UTP LOCATION, QTY
AS NOTED
TELECOM CABINET
TELECOM BUS-BAR
LOW VOLTAGE SLEEVE
REPLACE CABINETR
R
1 1
1 1
1 11 1
1 11 1
1 11 1
1 11 1
1 11 11 1
1 11 11 11 1
1 1
GENERAL NOTES
1. ALL UTP CABLE SHALL BE ANSI/TIA
CATEGORY 6A. PLACE WALL
LOCATIONS IN A SURFACE MOUNTED
SINGLE-GANG BACK BOX WITH A
WHITE TWO PORT FACEPLATE.
2. THE UNUSED TOP PORT OF THE
FACEPLATE IS TO BE FILLED WITH A
BLANK KEYSTONE JACK INSERT.
3. PLACE WALL LOCATIONS CENTERED
BELOW WHITEBOARD AT STANDARD
HEIGHT.
4. LOCATIONS WITHOUT WHITEBOARDS,
CENTER THE INSTALLATION ON THE
WALL AT STANDARD HEIGHT.
5. ALL CABLE BELOW CEILING SHALL BE
CONCEALED IN RACEWAY PROVIDED
BY CONTRACTOR.
6. PROVIDE CEILING LOCATION WITH
SERVICE LOOP LONG ENOUGH TO
REACH THE FARTHEST LOCATION IN
THE ASSOCIATED ROOM. SECURELY
FASTEN SERVICE LOOP TO
STRUCTURE.
7. TERMINATE ALL CATEGORY 6A CABLES
ON WHITE 8P/8C (RJ45) JACKS.
8. LOCATION OF BUS BLOCKS ARE
ESTIMATED, USE BEST PRACTICES
FOR INSTALLATION LOCATION.
9. FOR ESTIMATES ASSUME ALL
CABINETS NEED GROUNDING.
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
1/27/2025 DESIGN DLF
12/17/2024 DESIGN EGH
DATE ISSUE AUTHOR
SWARTZ CREEK
COMMUNITY SCHOOLS
STRUCTURED CABLING
SYRING ELEMENTARY
SCHOOL
T101
NTS
SYRING FLOOR PLAN
SE-T101