MIDDLE SCHOOL MS-T101-MS-T101B.pdf
PDF 434 KB Posted
- Attached to
- 2025 E-Rate Network Cabling Additions
- Solicitation number
- RFP-SCC-250000001194-2
- Issued by
- Michigan
About this file
This is a structured cabling design drawing for Swartz Creek Middle School Unit B, created by Convergent Technology Partners. The drawing details Category 6A UTP cable installation specifications for multiple classrooms and office spaces, including specific requirements for wall locations, faceplates, and ceiling installations. The design was authored by DLF and EGH, with dates of 12/17/2024 and 1/27/2025 respectively.
The technical specifications require all UTP cable to be ANSI/TIA Category 6A standard, with wall locations using surface-mounted single-gang back boxes and white two-port faceplates. Installation requirements include concealed raceway cabling below ceiling, service loops for ceiling locations, white 8P/8C (RJ45) jack terminations, and proper grounding for all cabinets. The floor plan shows multiple classrooms (401-412), offices, and work/pull rooms with specific UTP location markers and telecom cabinet placements. A symbol legend indicates wall UTP locations, ceiling UTP locations, telecom cabinets, telecom bus bar, and fireplace cabinet positions throughout the facility.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UNIT A
UNIT B
0' 5' 10' 20' 30' 40' 50'
NOT TO SCALE - BAR SCALE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1
1 1 1 1
TGB
SYMBOL LEGEND
WALL UTP LOCATION, QTY AS
NOTED
CEILING UTP LOCATION, QTY AS
NOTED
TELECOM CABINET
TELECOM BUS-BAR
REPLACE CABINETR
B
A
C D
E
FF
GENERAL NOTES
1. ALL UTP CABLE SHALL BE ANSI/TIA CATEGORY 6A.
PLACE WALL LOCATIONS IN A SURFACE MOUNTED
SINGLE-GANG BACK BOX WITH A WHITE TWO
PORT FACEPLATE.
2. THE UNUSED TOP PORT OF THE FACEPLATE IS TO
BE FILLED WITH A BLANK KEYSTONE JACK
INSERT.
3. PLACE WALL LOCATIONS CENTERED BELOW
WHITEBOARD AT STANDARD HEIGHT.
4. LOCATIONS WITHOUT WHITEBOARDS, CENTER
THE INSTALLATION ON THE WALL AT STANDARD
HEIGHT.
5. ALL CABLE BELOW CEILING SHALL BE
CONCEALED IN RACEWAY PROVIDED BY
CONTRACTOR.
6. PROVIDE CEILING LOCATION WITH SERVICE LOOP
LONG ENOUGH TO REACH THE FARTHEST
LOCATION IN THE ASSOCIATED ROOM. SECURELY
FASTEN SERVICE LOOP TO STRUCTURE.
7. TERMINATE ALL CATEGORY 6A CABLES ON WHITE
8P/8C (RJ45) JACKS.
8. LOCATION OF BUS BLOCKS ARE ESTIMATED, USE
BEST PRACTICES FOR INSTALLATION LOCATION.
9. FOR ESTIMATES ASSUME ALL CABINETS NEED
GROUNDING.
C O N V E R G E N T 6197 Miller Road Suite 4 Swartz Creek, MI 48473
Phone: 810.720.3820 www.ctpartners.net
T E C H N O L O G Y P A R T N E R S
TECHNOLOGY DESIGN I CONSULTING I PLANNING
1/27/2025 DESIGN DLF
12/17/2024 DESIGN EGH
DATE ISSUE AUTHOR
SWARTZ CREEK
COMMUNITY SCHOOLS
STRUCTURED CABLING
SWARTZ CREEK
MIDDLE SCHOOL
MS-T101B
KEYMAP