S02 F8-1 Laundry Equipment Storage 523A5-10-316 Laundry Building 45.pdf

PDF 444 KB Posted

Attached to
Z2EZ 523A5-10-316 Upgrade VISN 1 Laundry Building 45
Solicitation number
36C24125R0008
Issued by

About this file

This document is an inventory listing of excess and saved laundry equipment for the VA Boston Healthcare System's Brockton Campus, located in Laundry Facility Building 45. The inventory details two attachments with comprehensive equipment specifications across multiple categories of industrial laundry machinery.

Attachment II lists saved laundry equipment, which includes 12 items manufactured primarily by Chicago and Consolidated, such as a 500 lb gas heated pass-through dryer (Consolidated, 165 GP model, 2015), dry type lint collection system (Energenics FRP-20, 2015), and various flatwork spreaders, folders, and stackers. Attachment I provides an extensive inventory of excess laundry equipment dating from 1991 to 2015, encompassing a wider range of machinery including washer extractors, dryers, conveyor systems, water softening systems, air compressors, and supporting mechanical equipment from manufacturers like Gardner, Braun, Accurate Tech, McClure, and T.E.A. The equipment ranges in size from 41 lb to 800 lb capacity and includes specialized systems for textile processing, water treatment, and compressed air management.

View the file

Other files

File Type Posted
S06 Site Visit Sheet 7.28.2025.pdf PDF
S06 RFI Questions and Answers 8.11.2025 523A5-10-316 Upgrade VISN 1 Laundry Building 45.docx DOCX document
36C24125R0008 0007.docx DOCX document
S06 Updated Specifications 87100 R2.pdf PDF
S06 Updated Drawings Mechanical Rev2.pdf PDF
S06 Updated Drawings 10438_ELEC_REV2.pdf PDF
S06 Updated Drawings Plumbing Rev2 7-14-25.pdf PDF
S06 Updated Drawings 250716 FP REV 2.pdf PDF
S06 Updated Specifications 085113.pdf PDF
S06 2025-07-18 Addendum No. 2.pdf PDF
36C24125R0008 0006.docx DOCX document
S06 RFI Questions and Answers 523A5-10-316 Upgrade VISN 1 Laundry Building 45.docx DOCX document
S06 Updated Specifications 000110.pdf PDF
S06 Updated Drawings 2224 VA Brockton REV 2 architectural.pdf PDF
S06 Updated Drawings 2025-07-18 VA Brockton B45 Laundry Structural Rev 2.pdf PDF
S06 WD MA20250012 07.18.2025.pdf PDF
S06 36C24125R0008 0005.docx DOCX document
S06 36C24125R00008 0004.pdf PDF
36C24125R0008 0003.docx DOCX document
36C24125R0008 0002.docx DOCX document
36C24125R0008 0001.docx DOCX document
S06 Site Visit Sign In Sheet 4.24.2025.pdf PDF
S02 Base Offer Price Breakdown.xlsx XLSX spreadsheet
S02 F2-1 Structural Design Criteria 523A5-10-316 Laundry Building 45.pdf PDF
S02 F3-1 Code Search 523A5-10-316 Laundry Building 45.pdf PDF
S02 Attachment B Past Performance Project Information Sheet for 36C24125R0008.docx DOCX document
S02 F3-3 HLAC Accreditation Standards 09.21.2023 523A5-10-316 Laundry Building 45.pdf PDF
S02 Final Specifications 523A5-10-316 Laundry Building 45.pdf PDF
S02 Final Drawing Set 523A5-10-316 Laundry Building 45 08.21.2024.pdf PDF
S02 6500 Appendix B and C Security Language 523A-10-316 Laundry Building 45.pdf PDF
S02 Equipment List - Existing vs New Equipment 523A5-10-316 Laundry Building 45.pdf PDF
S02 Primavera P6 Schedule Review Checklist 523A5-10-316 Laundry Building 45.xlsx XLSX spreadsheet
S02 SOW 523A5-10-316 Laundry Building 45.pdf PDF
S02 F2-2 Attachment 2 Structural Calculations 523A5-10-316 Laundry Building 45.pdf PDF
S02 PCRA 523A5-10-316 Laundry Building 45.pdf PDF
S02 Final Drawings Revision 01 523A5-10-316 Laundry Building 45.pdf PDF
S02 Submittal Register 523A5-10-316 Laundry Building 45.xlsx XLSX spreadsheet
36C24125R0008_2.docx DOCX document
S02 Final Design Analysis Consolidated 523A5-10-316 Laundry Building 45.pdf PDF
S02 Attachment A Technical Project Information Sheet for 36C24125R0008.docx DOCX document
S02 WD MA20250012 04.04.2025.pdf PDF
S02 SSJ 523A-10-316 Laundry Building 45.pdf PDF
S02 Brockton Campus Map.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT II SAVED LAUNDRY EQUIPMENT VAMC BROCKTON, MA

VA Boston Healthcare System Brockton Campus - Laundry Facility Building 45 940 Belmont Street Brockton, MA 02301

Item QUANTITY ITEM DESCRIPTION MANUFACTURER MODEL YEAR MFG

; i '. • • , 1 EA' . • "'sdbl£:G~}i~~~!_EB:P~?s THROUGH D_R'vER : • coN~OLA~l\~~-P- : ~ .,,, :~?.$ G~: • 2ors ' ::J

2 1 EA DRY TYPE LINT COLLECTION SYSTEM ENERGENICS FRP-20 2015

--:~\ ' j:~~< f ~A:"- ~·~~TOMAT!CFLAJ~~f~:~p~~io,ffFE,fl),~~l_~· _·ce CHJ~AG~f -- --,~-'.KI NG.:EDG( c~~Y-, ;_: ,_;} ~,~f :_: .J

4 1 EA AUTOMATIC FLATWORK SPREADER FEEDER CHICAGO KING EDGE CT 2017

.:: "f ., •• -~fi;{ :-.-·~~i~ERMAL FLUID FLAfyi()Rk:1~Q~~ •;--:·.::)~i~J~t CHICAGO . PH·2-s2~c,--::cc"~-, ~: 2~ -i ~ '.79

6 1 EA THERMAL FLUID FLATWORK IRONER CHICAGO PH 2-52-CT-CC 2014

1 •. i Ef _':=~~ R-~E/~fy1~LLPi_EcE Focor~,~~9s1J·~~~Jl}·~i;It:~E~AlfAG~f --I_cLc_ _____ -~~1 ?-cT • - • • ioi 7 ~--J

8 1 EA LARGE/SMALLPIECE FOLDER CROSS FOLDER CHICAGO S-16-CT 2017

9 .. 1EA'> ' ' JA_RGE ' FLATWORK st~ckER W/CONVEYQB. }t{~,t~!c:~@)~~qJflCt~\s.o:ME AS FOLDER . '}014~ 1

10 1 EA LARGE FLATWORK STACKER W/CONVEYOR CHICAGO SAME AS FOLDER 2017

, '! 1 . :i E~ :=-< • ~··.L§FG(Pi~~f ~LANKETFEEDER··· ·-: -_ :-~1t{~Jl~}i,f2rsiii~~Gt>'.}JY""" 'Bl~_nk~t ~last~r 2017 . l

12 1 EA LARGE PIECE BLANKET FOLDER W/ STACKER CHICAGO S-13-88-CT 2017

,., :·,' • : •· \. · : • .,.,-=~-: ~..,:- .. ~ --~L .·i?~~_:, <t :? :;' -~ -

ATTACHMENT I EXCESS LAUNDRY EQUIPMENT VAMC BROCKTON, MA

VA Boston Healthcare System Brockton Campus - Laundry Facility Building 45 940 Belmont Street Brockton, MA 02301

Item QUANTITY ITEM DESCRIPTION MANUFACTURER MODEL YEAR MFG

1 . • 1 EJ ~;EJ(N~-~J~~cE-ss~cBbit WEIGH SCALE . . -: :.. . : _· UN.KNOWN'. i o,i6o PLATFORM (, UN~Nt ).\'ff}J J

2 1 SYS SOILED TEXTILE STORAGE/SORTING SYSTEM GARDNER TL/TW/TA 1991

-.c • • • -- .,c·--=·,--:-cc,-.,,..--~---~---- ,.- -, • • • ··- ·-----··- • • ~--. -._ i:ff;j'KNOWN 42x4·2 PLATFORrvi'.};·lJNl(l'JOWN I

- ---~.::.-::'1'l'i.%i~F } _;' NON~RECESSEDSOIL ~ EIG'='..i~f-~E~i:_·:~,..,_" _ ----- __ · _ ·-- .• •.c ,•,·c,c-sc ~'--~-' _ _;J

4 1 SYS SOILED CLASSIFIED MONORAIL CONVEYOR GARDNER NONE 1991

~}J fi~~:'~G3~ EA" 7 - • '800 LB. PASSTHROU~ H,WA.SHER-EirRACTOR -. : ~ BRAUN ~- ·, • • >:~r.a~~Tbf j '. >' 1991 .. , .·1

6 1 EA RAISED WASHER LOADING PLATFORM GARDNER CUSTOM 1991

C9_ 7'/?i . 2 EA ,_~boi s. !.~ SS·"I_H~_Q_UG~_~ ASHER_'EXT,RACTOR '.. - - -~R~~}s}~Ii\I.:2-~""iAQ~~N.!~P-_2 .•. : 19~1.-M

8 1 EA RAISED WASHER LOADING PLATFORM GARDNER CUSTOM 1991

-::::~)~ i/ , -1 EA 200 ·cs·:PA.~~ :tHRq,l}GH w.As/:ffR EXTR.AcroR -. --- -~-R~q ~ ;z~:t-i:)~?~.oof-Jrvn:0P~2 .---- -- 199i '·_· :~r i

10 1 SYS

·<11 :i, •• • • • 3 EA

12 1 EA

°'.\1-37~: • · 1 EA

CLEAN CLASSIFIED MONORAIL CONVEYOR

500 .LB GAS.HEATED-PASS THROUGH DRYERS

., ---·--·-··-i.:___, _ _.., .• ·. : . •

DRYER TAKE AWAY CONVEYOR

DRYER TAKE AWAY CONVEYOR

GARDNER CLEAN MONORAIL 1991

__ • ~C?~I<?L)\p~fEP:~~~t:k1~;}\{1~tg~ '.:' 201J _~~:g

GARDNER RSB 4225 2015

. GARDN(R'. ;:::::< /:',R$B;426q •· . • ••. 2015 ·1

14 3 EA DRY TYPE LINT COLLECTION SYSTEM ENERGENICS FRP-20 2015

>:Js_:s. •:< 4 EA i3o LB oPEN--~~-C.KEry~,~~~-ER txrRAcfo·R- •• - AccuRATE TEcH '.'::__sPnoE42sASt-JA~A _·-• :. 2011 :-~~

16 1 EA 105 LB OPEN POCKET WASHER EXTRACTOR ACCURATE TECH SP100E421ANNABA 2010

·_ ~?:-f'\Li,j} JiL\ . - :41 LB OPEN POCKET WA~HEREXTRACTOR-:- - A CCURATE TECH . SP40E421AS-NA8._A} _;k;iJ9·11 ,.

18 4 EA 100 LB GAS HEATED DRYER ACCURATE TECH DE170MR43S000LS0ABA 2010

::_J~JJ;S0.:'}@t {f\\~~': '} ?,LB GAS HEATED -~~~f.R.::)~:_~ :.~.i~i;::;: ::i ,ACCURATE.TtC~-•~ 0~7=~~~ s000.~g~~t it~f9P -,· .. J 20 1 EA CART WASHER WITH UV LIGHTING McCLURE SAN I-WASH 500 2014

. ~--i1;t::ftJl~8J~[ft:c~ir WASH p'LJMP/CO~TROr '. _-;·_,: ·-_.·_:;~;:: =:·_· ~-~ -~l cci..URE • NONE •• ··r~{/;;.fti g;1a

22 3 EA FLATWORK STORAGE/FEEDING CONVEYOR GARDNER FC-4x8 1991

•• : ~3:5'F7~-~};~z~ ~ @9:f?-EG R_EE TRANSFER c6r,Jy~EY.~R-,,~~ _;?: :~:~~r;-·~ i(. ;_BR,~UN . . 90DSSTC '. '·,,~,½·,;~;~~tt~~} ~-- ..

24 1 SYS CLEAN SIDE TAKE AWAY CONVEYOR SYSTEM GARDNER CL-TA22 1991

·2( ~-.~-}\~1,~t~iti:~"if ~EANDRv°FoCDc_LAss·,F1Eo MoNoR~1c___ ~-; :-r_;,: GARbNE..R • •• -· •. ·NONL ~ ~;~l??dt~!a: .. _ i

26 7 EA SMALL PIECE FOLDER BRAUN SIGMA SPFRF VARIES

-->-t•i t .ft~\;:·;}f ;-E~ ~[~':; fffANTEXTILE B.OLL.UP.TA~LES.: ;.~( ,_.~,~:°:}.;,.·GARDNER. ·_·--_F._R_s_·-_;_6_ Ox6_0 :,:it.~_:_r~_;. __ ;_'_-.·.~----~9_) _ '_:_,_ ....:...........:..,.i:::.::.,:: .... : ... ::.:.:.:..::-.~:.:=~ ...... 1.;;::~ • • • ,• ; • • " -4,' ' • , • •' ~~ - •• • .:,._':_._;.;• , ... ,n •,.:.•,... '• •-• • •• .• • TT--=-

28 1 SYS CLEAN TAKE AWAY CONVEYOR SYSTEM GARDNER CL·TA22 1991

{~:~~:;;~;y:j;-tl ~f( •. , CLE-AN TAKE AWAY,C~NVEYOR ._· , Hyi"ROL , - _ i; /. ~q~tJ ~}:1:i~fJ~-~}<NOWN !

30 1 EA CLEAN TEXTILE FLOW RACK GARDNER FR-7 x 17'0" 1991

,)'?-t~i f;c' •• 1 EA • :~L0 N Tf X_Tlff FLOW,R~S~ •. ·---~,----•• -. _·- •· '"C -- • ClJ~T,QM~fI"¾~~~::\,AN,( )Hc:-, ' •pNKN_QW-~ J

32 2 EA CLEAN TEXTILE STRAPPING MACHINE MOSCA ~~NONE UNKNOWN

33 2 ~/\ _ ji:. Q_t{rsciU_~~ER·--· ·r·-,- 2:i:t,~Eg_l7;8,tfr§~iR2;j ·tr.rT: Pf=-6000, UNKNOWN_' I

LAUNDRY MECHANICAL SUPPORT

EQUIPMENT

1-SYS . • - TWINW~TEKSQF,I~iJ~1G''BYSTEM:: -~

... _ 1(15~9 • ·-.· . ~ ,. _>.18~-Q:,c:·:· _ ,:; · :,.··: .~9~t ffi

35 1 SYS TWIN WATER SOFTENING SYSTEM GE OSMONIC E948-01F1-SOORB 2004

•_c.)~~~{J,;':1if~ tit•,~ ASTE''NAT~R ~E~t-~~.0i~~j·;:_:::;;_~~-'ft-:?'"~_.--i:;' :IE.A . . :· _: ·: :::: , '._~J~-:4:".::- ,-J',~fl0t£1!~9'.(1 ' • .I

37 1 EA WASTE WATER SUMP PUMP IPS 2014-08118 2014

'~:-38 FEA ., .. ~EMOTf STf'.IWS PAr-JEi •• : •.•• -~" ::'<" _:J~t:J.¥!?-J:iSE~1;il.jt1t}Sl'tJQ~·E:., "_ 19~1~;::-\J

39 1 EA TRIPLE PUMPING SYSTEM T.E.A. 15-HP 1991

. :.ao_,_-:--''"'~f EA'J·r 'cTEM~Ei~D~WA TER STO-R~~ §TANK ' ,-~~, -; .. ~. 7 .- T.E.-A: ·•- · )j( ~~::- t 3,oqb-GAL > . ':! , 1991, 41 1 EA HOT WATER STORAGE TANK T.E.A. 4,000 GAL 1991

~~~ ~J\-:~"1 ·~ ~·'t.~ .. ~} rEA~ ~"~i ~fie1f H°EArE·~-~::~:U}::-·~~-·~::~t;Iti~~J l :A ' .. ~ ~-~-!-·.·:·.~:N-6N{ 7::- .\_c-.t~( ¥~Ifi 1,"-J

43 1 EA HOT WATER CIRCULATION PUMP T.E.A. NONE 1991

---· . .. ---,.~-.--, • . ,-,,c,,;,-,=-·~~. -, ••• --:,,·----=-~ --,--""'"'"'" ,- - • ·-•.,-, •-.,.,--,...,: . '""'"'- '"""~· ~- ·- J ;~~44 . : .. 1 EA·· .q t,;1~1{ {\E.U_SE WATE~ P!JlylPING PAClq9f Jft·' . T.E;A( ,.· , . • , •• ,1!).::_tl~::~:~;t; ·: 19~1·i_>_'j

45 1 EA REUSE WATER STORAGE TANK T.E.A. 1,500 GAL 1991

•• ~~~ ;;-- ··'.: 1 ·s2'.? ,:{/ti;¢.oNDEN~1!J ~_q~p RET~-~N._§JSJ,~M.-.·· ;_ ·--~·-. -~:_---~- --~~ :.:/~f~9NE .... ~g ~ KNO.WNj

47 2 EA AIR COMPRESSOR (BASE-MOUNTED) GARDNER DENVER EBEQFC UNKNOWN

," 48 1,EA~'f,. DUAL piJt-.1P M ODULE _'\· - -· • ~-.· -~- NAM·coT/f~;t:-_::::•"E~lSOPSO _;: ·; ~ "."' 1995

49 1 EA AIR COMPRESSOR (TANK MOUNTED) GARDNER DENVER UNKNOWN UNKNOWN

t'so .. •i .·!_~~~A •- _AJ.Rl co ~ PREs?g~ ~2iff~1!¥ sE MouNi"_Eoi~. -- -~AR?NE(f2'~-'?E .. R_,cc-- • • 0.~gg~=~~-~- • _ 2o;c1_5,:,~~

51 1 EA COMPRESSED AIR DRYER HANKISON HPRP200-230 2000

,s2 >:§_A s·vs ,:;qENTRt.£.v AC:W Qr0"~T£ M • . , • -·~ ~ • ,. • .. : <:::,~(~\ -__ ;. -._ • - ---~-~:~: - · ·_ LiNf~-N !

File details come from the government source that posted it. Updated .