This document is an Attachment 2 Structural Calculations file for the 523A5-10-316 Laundry Building 45 project, associated with the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1. The structural calculations provide design criteria for an existing steel-framed building, focusing on floor model analysis and foundation checks. The key technical specifications include a standard 100 psf load for floor analysis, with modifications for areas where new equipment dead loads exceed this standard. The calculations cover existing steel joist floor analysis, stair member design, and existing concrete beam/slab reinforcing design, indicating a comprehensive structural assessment of the facility's load-bearing capabilities and potential upgrade requirements.
View the file
Other files for this federal contract opportunity
Show all 43
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 2 Structural Calculations
Design Criteria
Existing Steel Framed Building Floor Model
Floor analyzed based off existing conditions with 100 psf load except in areas where new equipment dead loads exceed 100 psf. At these locations the equipment dead loads only were used as the area is completely covered by the equipment
Existing Steel Framed Building Foundation Checks
Existing Concrete Beam/Slab Reinforcing Design
Existing Steel Joist Floor Analysis and Stair Member Design