S02 - Attachment 7(b) - Technology Cut Sheets - Part 2 of 11 Corning.pdf
PDF 38 MB Posted
- Attached to
- EHRM San Antonio Infrastructure Upgrades Construction (SDVOSB Set-Aside and 236220 NAICS) Federal contract opportunity
- Solicitation number
- 36C77623B0064
About this file
This attachment is a 38MB file containing technology cut sheets for the EHRM San Antonio Infrastructure Upgrades Construction project. The related federal contract opportunity is solicitation number 36C77623B0064 from the Department of Veterans Affairs Technology Acquisition Center Austin for infrastructure upgrades at VA medical centers in San Antonio. The opportunity is set aside for service-disabled veteran-owned small businesses and has a NAICS code of 236220 for commercial and institutional building construction. The solicitation seeks construction services to upgrade infrastructure systems at VA facilities, as detailed in the technology cut sheets. The response deadline and award date are not specified in the attachment.
View the file
Other files for this federal contract opportunity
Show all 50
EHRM San Antonio Infrastructure Upgrades Construction (SDVOSB Set-Aside and 236220 NAICS) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Features and Benefits Gel-free waterblocking technology Craft-friendly cable preparation
Loose tube design Stable performance and compatibility with all common fiber types
Color-coded tubes and fibers Quick and easy identification
All-dielectric construction Requires no grounding or bonding
Common installations Outdoor lashed aerial and duct; indoor vertical riser and general purpose horizontal according to National Electrical Code (NEC) Article 770
FREEDM® Loose Tube, Gel-Free Cable, Riser, 24 F, SMF-28® Ultra fiber, Single-mode (OS2) 024EUF-T4101D20
Part Number:
024EUF-T4101D20
Corning FREEDM® loose tube gel-free riser cables are flame-retardant, indoor/outdoor, riser-rated cables designed for interbuilding and intrabuilding backbones in aerial, duct and riser applications. These cables are protected against water penetration by innovative waterblocking materials that swell to absorb water. Waterblocking without the use of messy gels provides more efficient and craft-friendly cable preparation. It also makes cable access easier and simplifies the use of buffer tube fan-out kits. The buffer tubes and fibers in each tube are color coded for quick, easy identification. The SZ-stranded, loose tube design isolates fibers from installation and environmental rigors and allows for easy mid-span access. The cable design is also National Electrical Code® (NEC®) listed (OFNR and FT-4). The all-dielectric cable construction requires no grounding or bonding, and the UV-resistant, flame-retardant jacket is rugged, durable and easy to strip. Note: This cable is available in 12 different jacket colors – blue, orange, green, brown, slate, white, red, black, yellow, violet, rose and aqua.
The colored jacket allows for easy visual identification of the cables while still providing all of the required environmental protection of an indoor/outdoor cable jacket. Black is the standard jacket color using the part numbers shown here.
Contact Customer Care at 1-800-743-2675 to order other color options.
FREEDM® Loose Tube, Gel-Free Cable, Riser 24 F, Single-mode (OS2)
Product Specification 024EUF-T4101D20_NAFTA_AEN Page 1 | Revision Date 2021-10-27
Specifications
Mechanical Specifications
Max. Tensile Strength, Long-Term 810 N (182.1 lbf)
Max. Tensile Strength, Short-Term 2700 N (606.98 lbf)
Min. Bend Radius Installation 195 mm (7.68 in)
Min. Bend Radius Operation 130 mm (5.12 in)
Nominal Outer Diameter 13 mm (0.51 in )
Cable Design
Central Element Dielectric
Fiber Count 24
Buffer Tube Color Coding Blue, Orange
Number of Ripcords 2
Outer Jacket Color Black
Outer Jacket Material Flame-Retardant, UV-Resistant
Buffer Tube Color Blue, Orange
Buffer Tube Diameter 2.5 mm (0.1 in)
Number of Active Tubes 2
Number of Filling Elements 4
Number of Tube Positions 6
Tape Water-swellable
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12
Environmental Conditions
Temperature Range, Installation -10 C to 60 C (14 F to 140 F )
Temperature Range, Storage -40 C to 70 C (-40 F to 158 F )
FREEDM® Loose Tube, Gel-Free Cable, Riser 24 F, Product Specification 024EUF-T4101D20_NAFTA_AEN Page 2 | Revision Date 2021-10-27
Environmental Conditions
Temperature Range, Operation -40 C to 70 C (-40 F to 158 F )
General Specifications
Environment Indoor/Outdoor
Cable Type Loose Tube
Product Type Dielectric
Fiber Category Single-mode (OS2)
Flame Rating Riser (OFNR)
Application Aerial, Direct Buried, Duct, General Purpose Horizontal
Ordering Information
Product Number 024EUF-T4101D20
EAN Code 4056418174709
Weight 146 kg/km (98.11 lb/1000 ft)
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Approvals and Listings National Electrical Code® (NEC®) OFNR, CSA OFN FT-4
Design and Test Criteria ANSI/ICEA S-104-696
Optical Characteristics
Fiber Code E
Fiber Name Single-mode (OS2)
Fiber Type Single-mode
Performance Option Code 01
Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
FREEDM® Loose Tube, Gel-Free Cable, Riser 24 F, Product Specification 024EUF-T4101D20_NAFTA_AEN Page 3 | Revision Date 2021-10-27
Optical Characteristics
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Category G.652.D
Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC • 28216 • United States 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm
A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2021 Corning Optical Communications. All rights reserved.
FREEDM® Loose Tube, Gel-Free Cable, Riser 24 F, Single-mode (OS2)
Product Specification 024EUF-T4101D20_NAFTA_AEN Page 4 | Revision Date 2021-10-27 https://www.corning.com/opcomm
Low-smoke, zero-halogen sheath Key life-safety benefit
Meets cyclic impact and chemical resistance test Superior performance
Available in MSHA versions Mine Safety and Health Administration approved
Common installations Outdoor aerial and duct; indoor general purpose horizontal according to NEC Article 770
LSZH™ Riser Indoor/Outdoor, Loose Tube, Gel-Free, Double-Jacket Cable, 24 F, Single-mode (OS2)
Part Number:
024EUK-T4601D20
Corning LSZH™ and Riser-rated loose tube gel-free cables are flame-retardant, indoor/outdoor, suitable for installation in interbuilding and intrabuilding applications. The loose tube design offers mechanical ruggedness and environmental durability while the all-dielectric cable construction requires no grounding or bonding. The water-swellable yarn eliminates the need for gel-filling compound and allows more efficient and craft-friendly cable preparation. The 250 µm color-coded fibers allow quick and easy identification during installation.
Corning LSZH cables eliminate risks in the event of a fire as the LSZH compound does not drip when superheated.
The material burns to ash, eliminating the onset of secondary fires. When cables containing halogens ignite, they emit highly reactive gases that can be harmful if inhaled. When halogens combine with water, acids are formed. These acids damage both living tissue and inorganic materials, such as metal and electronic equipment. The flexible, flame-retardant outer jacket is UV-resistant and enables direct exposure to sunlight.
Interlocking armor is available for special applications requiring additional mechanical durability. The Riser rating allows for the cable to transition into a Riser-rated building space without the need of a transition splice that costs time and money.
Riser LSZH™ Indoor/Outdoor, Loose Tube, Gel- Free, Double-Jacket Cable 24 F, Single-mode
(OS2)
Product Specification 024EUK-T4601D20_NAFTA_AEN Page 1 | Revision Date 2021-08-29
Max. Tensile Strength, Long-Term 1500 N (337.21 lbf)
Max. Tensile Strength, Short-Term 4500 N (1011.64 lbf)
Min. Bend Radius Installation 269 mm (10.59 in)
Min. Bend Radius Operation 179 mm (7.05 in)
Nominal Outer Diameter 17.9 mm (0.7 in )
Cable Design
Central Element Dielectric
Fiber Count 24
Buffer Tube Color Coding Blue, Orange
Number of Ripcords 4
Outer Jacket Color Black
Outer Jacket Material Flame-retardant, non-corrosive/low-smoke, zero-halogen (FRNC/LSZH) material
Tensile Strength Elements and/or Armoring - Layer 1 Dielectric strength members
Buffer Tube Color Blue, Orange
Buffer Tube Diameter 2.5 mm (0.1 in)
Inner Jacket Material Flame-retardant, non-corrosive/low-smoke, zero-halogen (FRNC/LSZH) material
Number of Active Tubes 2
Number of Filling Elements 4
Number of Tube Positions 6
Tape, Layer 1 Water-swellable
Tape, Layer 2 Flame-retardant tape
Tape, Layer 3 Water-swellable
Tape, Layer 4 Water-swellable
Riser LSZH™ Indoor/Outdoor, Loose Tube, Gel- Free, Double-Jacket Cable 24 F, Single-mode
Product Specification 024EUK-T4601D20_NAFTA_AEN Page 2 | Revision Date 2021-08-29
Cable Design
Fiber Coloring Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Rose, Aqua
Fibers per Tube 12
General Specifications
Fiber Category Single-mode (OS2)
Application Aerial, Duct, General Purpose Horizontal
Fiber Count 24
Environment Indoor/Outdoor
Cable Type Loose Tube
Product Type Dielectric
Flame Rating LSZH™ (OFNR-LS)
Ordering Information
Product Number 024EUK-T4601D20
Weight 312 kg/km
Environmental Conditions
Temperature Range, Installation -30 °C to 60 °C (-22 F to 140 F )
Temperature Range, Operation -40 °C to 70 °C (-40 F to 158 F )
Temperature Range, Storage -40 °C to 70 °C (-40 F to 158 F )
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Riser LSZH™ Indoor/Outdoor, Loose Tube, Gel- Free, Double-Jacket Cable 24 F, Single-mode
Product Specification 024EUK-T4601D20_NAFTA_AEN Page 3 | Revision Date 2021-08-29
Fiber Code E
Fiber Name Single-mode (OS2)
Fiber Type Single-mode
Performance Option Code 01
Maximum Attenuation 0.4 dB/km / 0.4 dB/km / 0.3 dB/km
Wavelengths 1310 nm / 1383 nm / 1550 nm
Fiber Category G.652.D
Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC • 28216 • United States 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm
A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2021 Corning Optical Communications. All rights reserved.
Riser LSZH™ Indoor/Outdoor, Loose Tube, Gel- Free, Double-Jacket Cable 24 F, Single-mode
(OS2)
Product Specification 024EUK-T4601D20_NAFTA_AEN Page 4 | Revision Date 2021-08-29 https://www.corning.com/opcomm
Binderless FastAccess™ Technology Innovative cable design that reduces cable access time up to 70% and lowers the risk of inadvertent fibre damage
Fully waterblocked loose tube all-dielectric gel-free design Simple access and no clean up
Fibres/buffer tubes colour coded to Telcordia-Bellcore Easy identification of the individual tubes and fibres
Available with G.652.D and/or G.657.A1 fiber Ready for any application
All-dielectric cable construction Requires no grounding or bonding
Part Number:
024ZP4-T3F20D20
Corning ALTOS® cable with Binderless FastAccess® technology is an all-dielectric gel-free cable designed for outdoor and limited indoor use for lashed aerial and duct installations. The innovative FastAccess technology feature combined with the gel-free binderless loose tube design simplifies removal of the cable jacket and accessing the buffer tubes. The loose tube design uses Corning's SMF-28® Ultra fiber to provide reliable transmission parameters for a variety of voice, data, video and imaging applications. The cable is fully waterblocked using craft-friendly, water-swellable materials, which means no cleanup is required. The flexible buffer tubes are easy to route in closures, and the SZ-stranded, loose tube design isolates fibers from installation and environmental rigors while allowing easy midspan access. The all-dielectric gel-free cable construction requires no bonding or grounding, and these cables have a medium-density polyethylene jacket that is rugged, durable and easy to handle.
ALTOS® Loose Tube, Gel-Free, All-Dielectric, Non- Armoured Cables with Binderless FastAccess™ Technology 2x12 F, SMF-28® ULTRA, LT 2.0 HDPE
Product Specification 024ZP4-T3F20D20_EMEA_BEN Page 1 | Revision Date 2021-09-16
Crush resistance 1500 N/10 cm
Max. tensile strength for installation 1500 N
Min. bend radius installation 170 mm
Min. bend radius operation 85 mm
Nominal outer diameter 8.5 mm
Weight 51 kg/km
Cable Design
Cable marking Metre - Handset - Sine - CORNING - Year - ALTOS (R) Gel-Free FastAccess 2X12 E9U LT 2.0
Central element Glass reinforced Plastic (Dielectric)
Fibre count 24
Buffer tube colour coding Blue, orange
Outer jacket colour Black
Outer jacket material High Density Polyethylene (HDPE)
Outer jacket nominal thickness 1.1 mm
Buffer tube colour Blue, orange
Buffer tube diameter 2 mm
Central element diameter 2.1 mm
Number of active tubes 2
Number of filling elements 4
Number of tube positions 6
Fibre colouring Blue, orange, green, brown, grey, white, red, black, yellow, violet, pink, turquoise
Fibres per tube 12
SAP Powder Water-swellable
ALTOS® Loose Tube, Gel-Free, All-Dielectric, Non- Armoured Cables with Binderless FastAccess™
Product Specification 024ZP4-T3F20D20_EMEA_BEN Page 2 | Revision Date 2021-09-16
Environmental Conditions
Temperature range, installation -5 °C to 50 °C
Temperature range, operation -30 °C to 70 °C
Temperature range, storage -40 °C to 70 °C
General Specifications
Environment Outdoor
Cable type Loose tube
Product type Dielectric
Fibre category SMF-28® Ultra fibre ITU-TG.652.D + ITU-TG.657.A1
Application Duct
Coding according to EN 60794-1-1 (DIN VDE 0888-100-1) A-BQ(ZN)2Y
Ordering Information
Product Number 024ZP4-T3F20D20
Weight 51 kg/km
Standards
RoHS Free of hazardous substances according to RoHS 2011/65/EU
Approvals and Listings IEC 60794-3-10
Waterblocking IEC 60794-1-2 F5
Optical Characteristics
Cable cutoff wavelength 1260 nm
Fibre code Z
Fibre name E9/125 SMF-28® Ultra
Fibre Type Single-mode
ALTOS® Loose Tube, Gel-Free, All-Dielectric, Non- Armoured Cables with Binderless FastAccess™
Product Specification 024ZP4-T3F20D20_EMEA_BEN Page 3 | Revision Date 2021-09-16
Fibre compliance ITU-T G.652.D and ITU-T G.657.A1
Fibre core diameter 8.2 µm
Maximum Attenuation 0.34 dB/km / 0.20 dB/km
Serial 1 gigabit ethernet 5000 MHz*km / -
Serial 10 gigabit ethernet 10000 MHz*km / 40000 MHz*km
Typical attenuation 0.32 dB/km / 0.18 dB/km
Wavelengths 1310 nm / 1550 nm
Corning Optical Communications GmbH & Co. KG • Lelpziger Strasse 121 • 10117 Berlin, Germany +00 800 2675 4641 • FAX: +49 30 5303 2335 • www.corning.com/opcomm/emea
A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/emea/trademarks. Corning Optical Communications is ISO 9001 and ISO 14001 certified. © 2021 Corning Optical Communications. All rights reserved.
ALTOS® Loose Tube, Gel-Free, All-Dielectric, Non- Armoured Cables with Binderless FastAccess™ Technology 2x12 F, SMF-28® ULTRA, LT 2.0 HDPE
Product Specification 024ZP4-T3F20D20_EMEA_BEN Page 4 | Revision Date 2021-09-16 https://www.corning.com/opcomm/emea
Product: 2139A
Category 5e Indoor/Outdoor OSP/CM-LS LSZH 25pr Corrugated Shield
Product Description CAT5e (100MHz), 25-Pair, Unshielded Pairs, Rated-CM-LS, Indoor/ Outdoor Premise Backbone Cable, 24 AWG solid bare copper conductors, Polyolefin insulation, Polymer Gel Waterblocked, Polyolefin Inner Jacket, Corrugated Aluminum Tape, FR Polyolefin Outer Jacket
Technical Specifications
Product Overview
Suitable Applications: OSP-Outdoor, Indoor/Outdoor, Premise Backbone Cable, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments
Physical Characteristics (Overall)
Conductor
AWG Stranding Material No. of Pairs
24 Solid BC - Bare Copper 25
Conductor Count: 50
Total Number of Pairs: 25
Insulation
Material
PO - Polyolefin
Bonded-Pair: N/A
Color Chart
Number Color
1 Black & Blue
2 Black & Orange
3 Black & Green
4 Black & Brown
5 Black & Gray
6 Yellow & Blue
7 Yellow & Orange
8 Yellow & Green
9 Yellow & Brown
10 Yellow & Gray
11 Purple & Blue
12 Purple & Orange
13 Purple & Green
14 Purple & Brown
15 Purple & Gray
16 White & Orange
17 White & Green
18 White & Brown
19 White & Gray
20 Red & Blue
21 Red & Orange https://catalog.belden.com/index.cfm?event=pd&p=PF_2139A&tab=downloads https://catalog.belden.com/index.cfm?event=pd&p=PF_2139A&tab=downloads
22 Red & Green
23 Red & Brown
24 Red & Gray
25 White & Blue
Inner Jacket
Material Nominal Diameter Ripcord
PE - Polyethylene 0.51 in Yes
Water Penetration: GR 421CORE para. 4.3.5.1, ANSI/ICEA S107704 para. 8.2.1, ANSI/ICEA S-99-689
Outer Shield
Material
Aluminum
Outer Jacket
Material Nominal Diameter Ripcord
LSZH - Low Smoke Zero Halogen (Flame Retardant) 0.730 in Yes
Construction and Dimensions
Armor
Type of Armor Material Thickness of Armoring Tape
Corrugated Aluminum .008 in
Electrical Characteristics
Conductor DCR
Max. Conductor DCR Max. DCR Unbalance
93.8 Ohm/km 5 %
Capacitance
Max. Capacitance Unbalance Nom.Mutual Capacitance
330 pF/100m 14 pF/ft
Delay
Frequency [MHz] Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%]
100 MHz 537.6 ns/100m 45 ns/100m 68%
High Frequency
Frequency [MHz] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. RL (Return Loss) [dB] Max./Min. Fitted Impedance
1 MHz 2.0 dB/100m 62.3 dB 20.0 dB 100 ± 15%
4 MHz 4.1 dB/100m 53.3 dB 23.0 dB 100 ± 15%
8 MHz 5.8 dB/100m 48.8 dB 24.5 dB 100 ± 15%
10 MHz 6.5 dB/100m 47.3 dB 25.0 dB 100 ± 15%
16 MHz 8.2 dB/100m 44.3 dB 25.0 dB 100 ± 15%
20 MHz 9.3 dB/100m 42.8 dB 25.0 dB 100 ± 15%
25 MHz 10.4 dB/100m 41.3 dB 24.3 dB 100 ± 15%
31.25 MHz 11.7 dB/100m 39.9 dB 23.6 dB 100 ± 15%
62.5 MHz 17.0 dB/100m 35.4 dB 21.5 dB 100 ± 15%
100 MHz 22.0 dB/100m 32.3 dB 20.1 dB 100 ± 15%
Voltage
UL Voltage Rating
300 V RMS
Temperature Range
Installation Temp Range: -20°C To +75°C
UL Temp Rating: 75°C
Storage Temp Range: -40°C To +75°C
Operating Temp Range: -40°C To +75°C
Mechanical Characteristics
Cold Bend Test: -20°C Compliance per UL 1581
Bulk Cable Weight: 240 lbs/1000ft
Max. Pull Tension: 150 lbs
Min. Bend Radius During Installation: 14.75 in
Min. Bend Radius/Minor Axis: 7.5 in
Standards
NEC/(UL) Compliance: CM-LS
CEC/C(UL) Compliance: CM-LS
ISO/IEC Compliance: 11801 ed 2.2 (2011) Class D
Data Category: Category 5e
ANSI Compliance: S-90-661-2012 Category 5e, ANSI/NEMA WC-63.1 Category 5e
TIA/EIA Compliance: ANSI/TIA-568-C.2 Category 5e
IEEE Compliance: IEEE 802.3bt Type 1, Type 2, Type 3
Other Specification: Outdoor Use ANSI/ICEA S56434, Broadband Outdoor Use ANSI/ICEA S99689, Indoor/Outdoor Use ANSI/ICEA S100685
Applicable Environmental and Other Programs
Environmental Space: Indoor/Outdoor
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
EU Directive 2003/96/EC (BFR): Yes
EU Directive 2011/65/EU (RoHS 2): Yes
EU Directive 2012/19/EU (WEEE): Yes
EU Directive 2015/863/EU (RoHS 2 amendment): Yes
EU Directive Compliance: Yes
EU CE Mark: Yes
EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10
EU RoHS Compliance Date (yyyy-mm-dd): 2015-10-27
MII Order #39 (China RoHS): Yes
Suitability
Suitability - Aerial: Yes - When supported by messenger wire
Suitability - Burial: Yes - Engineered burial only
Suitability - Hazardous Locations: No
Suitability - Indoor: Yes
Suitability - Non-Halogenated: No
Suitability - Oil Resistance: No
Suitability - Outdoor: Yes
Suitability - Sunlight Resistance: Yes
Flammability, LS0H, Toxicity Testing
UL Flammability: UL 1685 (UL Loading-Limited Smoke)
UL voltage rating: 300 V RMS
Plenum/Non-Plenum
Plenum (Y/N): No
Part Number
Variants
Item # Color UPC
2139A 0101000 Black 612825377870
Product Notes
Notes: Electrical values are expected performance based on cable testing and representative performance within a typical Belden system. Print Includes Descending Footage Markings. Not Suitable for Direct Burial.
History
Update and Revision: Revision Number: 0.302 Revision Date: 09-08-2021
© 2021 Belden, Inc All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.
LA N -Trak OSP Category 5e 25 Pair #24 AWG ScTP C a t e g o ry 5e Outdoor Cable
PHYSICAL CHARAC T E R I S T I C S
CABLE W E I G H T: 300 lbs/1000ft (446 kg/km) BEND RADIUS: 1 1 . 0 ” (279 mm) MIN (15 x CABLE OD) PULLING T E N S I O N : 165 lbf (750 N) MAX O P E R ATING T E M P. : –40°C to +60°C (–40°F to +140°F) S TO R AGE T E M P. : –40°C to +75°C (–40°F to +167°F) I N S TA L L ATION – 2 0°C to +60°C (– 4°F to +140°F) T E M P. * :
*THE INSTA L L ATION T E M P E R ATURE REFERS TO THE T E M P E R ATURE OF T H E
C A B L E WHILE BEING INSTALLED OR PULLED.
M O H AW K
Cabling Excellence for Open Architecture
A P P L I C AT I O N S
10BASE-T (ETHERNET), 100BASE-T (FAST ETHERNET), A N D
1000BASE-T (GIGABIT ETHERNET), FDDI T P - P M D, IEEE 802.5 4 AND
16 Mbps TOKEN RING, ATM UP TO 155 Mbps AND STA N DA R D S UNDER DEVELOPMENT SUCH AS ATM AT 622 Mbps.
C O N S T RU C T I O N
P R I M A R I E S : C O N D U C TO R : 24 AWG (.5 mm) SOLID BARE
C O P P E R
I N S U L AT I O N : THERMOPLASTIC POLYO L E F I N
PAIR ASSEMBLY: 2 PRIMARIES TWISTED IN VARIED LAY S
CABLE ASSEMBLY: 25 PAIRS CABLED TO G E T H E R
B I N D E R : OVERALL OPEN BINDER
INNER JAC K E T: M AT E R I A L : MEDIUM DENSITY POLY E T H Y L E N E
NOMINAL WA L L : . 0 4 0 ” (1.0 mm) NOMINAL DIAMETER: . 5 1 0 ” (12.95 mm)
C O L O R : B L AC K
S H I E L D: C O R RU G ATED ALUMINUM TAPE .008” (.20 mm)
OUTER JAC K E T: M AT E R I A L : MEDIUM DENSITY POLY E T H Y L E N E
NOMINAL WA L L : . 0 6 0 ” (1.5 mm) NOMINAL DIAMETER: . 7 3 0 ” (18.54 mm)
C O L O R : B L AC K
P R I N T: M O H AWK 25PR 24 AWG CAT 5E -- M58527
( W / S E QUENTIAL FOOTAGE MARKERS)
N OT E : CABLE FLOODED FOR MOISTURE PROTECTION
PART # M58527
ELECTRICAL CHARAC T E R I S T I C S
S TA N DA R D S : TIA/EIA 568-B.2 CAT 5e BACKBONE
CABLE, MEETING POWERSUM NEXT,
ANSI/ICEA S-99-689-1997
VO LTAGE RAT I N G : 300 VO LT S
C O N D U C TOR DCR: 938 Ω/100m (28.6 Ω/Mft) MAX
C A PAC I TA N C E : 51 pF/m (15.7 pF/ft) NOM
C A PAC I TA N C E U N BA L A N C E
PA I R / G RO U N D : 330 pF/100m (1000 pF/Mft) MAX
C H A R AC T E R I S T I C
I M P E DA N C E : 100 Ω ± 15% (1-100 MHz)
RETURN LOSS (RL): 20 + 5 log10 (f ) dB MIN (1-10 MHz) 25 dB MIN (>10-20 MHz) 25 - 7 log10 (f /20) dB MIN (>20 MHz)
I N S E RTION LOSS: 1.967 ÷f + .023 f + dB/100m MAX
P OWER SUM NEAR E N D
C RO S S TALK (PS-NEXT): 32.3 - 15 log10 (f /100) dB/100m MIN
P OWERSUM EQUAL LEVEL FA R E N D
C RO S S TALK (PS-ELFEXT): 20.8 - 20 log10 (f /100) dB/100m MIN
P RO PAG AT I O N D E L AY: 534 + 36 / ÷f ns/100m MAX
D E LTA D E L AY (SKEW): 45 ns/100m MAX
N O M I N A L VELOCITY OF 65%
P RO PAG ATION (NVP):
WHERE f = FREQUENCY IN MHz from .772 to 100 MHz.
. 0 5 0 ÷f
LanTrak Cat5e 25 Pair 5/6/09 2:04 PM Page 1
M O H AW K
Cabling Excellence for Open Architecture
LA N -Trak OSP Category 5e 25 Pair #24 AWG ScTP Category 5e Outdoor Cable
9 Mohawk Dri ve, Leominster, MA 01453
(978) 537-9961 • 1-800-422-9961 • FAX (978) 537-4358
i n fo @ m o h aw k - c a bl e.com www. m o h aw k - c a bl e. c o m © M o h awk 5/2009
Mohawk reserves the right to change specification in the interest of product enhancement.
FREQ I N S E RT I O N LOSS PS-NEXT P S - ACR* PS-ELFEXT R L
( M H z ) (dB/100m) (dB//mft) ( d B / 1 0 0 m ) ( d B / 1 0 0 m ) ( d B / 1 0 0 m ) ( d B ) av g m a x m a x av g m i n m i n m i n m i n . 7 7 2 1 . 5 1 . 8 5 . 5 7 0 6 4 . 0 6 2 . 2 - - 1 . 0 1 . 9 2 . 0 6 . 3 6 8 6 2 . 3 6 0 . 3 6 0 . 8 2 0 . 0 4 . 0 3 . 8 4 . 1 1 3 5 7 5 3 . 3 4 9 . 2 4 8 . 7 2 3 . 0 8 . 0 5 . 4 5 . 8 1 8 5 4 4 8 . 8 4 3 . 0 4 2 . 7 2 4 . 5 1 0 . 0 6 . 1 6 . 5 2 0 5 2 4 7 . 3 4 0 . 8 4 0 . 8 2 5 . 0 1 6 . 0 7 . 8 8 . 2 2 5 5 0 4 4 . 3 3 6 . 1 3 6 . 7 2 5 . 0 2 0 . 0 8 . 8 9 . 3 2 8 4 8 4 2 . 8 3 3 . 5 3 4 . 7 2 5 . 0 2 5 . 0 9 . 9 1 0 . 4 3 2 4 7 4 1 . 3 3 0 . 9 3 2 . 8 2 4 . 3 3 1 . 2 5 1 1 . 1 1 1 . 7 3 6 4 6 3 9 . 9 2 8 . 2 3 0 . 9 2 3 . 6 6 2 . 5 1 6 . 0 1 7 . 0 5 2 4 2 3 5 . 4 1 8 . 4 2 4 . 8 2 1 . 5 1 0 0 . 0 2 0 . 5 2 2 . 0 6 7 3 8 3 2 . 3 1 0 . 3 2 0 . 8 2 0 . 1
* ACR - AT T E N UAT I O N TO C RO S S TA L K R AT I O
LanTrak Cat5e 25 Pair 5/6/09 2:04 PM Page 2
COMMUNICATIONS
www.SuperiorEssexCommunications.com
CATALOG
800.551.8948 SuperiorEssexCommunications.com
All information, content, data, specifications, packaging and part numbers detailed herein are subject to change. For the most up-to-date information, please visit SuperiorEssexCommunications.com. Purchase of this product is subject exclusively to the then current Superior Essex International LP Terms and Conditions of Sale for Communications Cable, Wire and Connectivity Products, which can be found on our website, SuperiorEssexCommunications.com, or provided to you upon request.
About Superior Essex Superior Essex International LP is a global leader in the design, manufacture, and supply of communications and energy cable products for indoor and outdoor applications. We offer a broad communications portfolio including premises optical fiber and copper cables, Outside Plant (OSP) cables, Fire Alarm and Security (FAS) cables, and Wireless cables and accessories. With over eighty years serving the communications and energy markets, we have cultivated a solid reputation as the preferred supplier of high-performance cabling for major communications service providers, leading enterprises, universities, hospitals, military facilities and businesses that rely on our innovative solutions to meet the demands of their evolving networks.
Our Commitments to Transparency and Sustainability Superior Essex is firmly committed to environmental responsibility and transparency, and we constantly strive to lead innovation and design toward sustainable product solutions.
We are the first wire and telecommunications cable manufacturer to conduct an independent full Life Cycle Assessment examining the environmental impact of our high performance copper and optical fiber data cabling products, including our raw materials, manufacturing, transportation, installation, and end of life practices.
We are also the first in our industry to contribute toward LEED certification by offering Environmental Product Declarations (EPD) and Health Product Declarations™ (HPD™) for our premises copper and optical fiber cable products. Additionally, we offer Multi-Attribute Certifications for our premises copper products, which provide transparency into our manufacturing processes and help government procurement agents meet their sustainability goals by simplifying the sustainable supplier selection process.
As the first and only sustainable and transparent cable manufacturer, we are the preferred choice for all enterprises relying on sustainable cabling solutions.
UL and the related logo are registered trademarks of UL LLC. Health Product Declaration, HPD and the related logo are trademarks of Health Product Declaration Collaborative. GreenCircle Certified logo is a registered trademark of GreenCircle Certified, LLC. USGBC and the related logo are registered trademarks of U.S. Green Building Council.
A S
U
ST
AI
NABLE SOLUTION
Z E R O WA STE T
O
L A
N D
FI
LL
http://ce.superioressex.com/ https://superioressexcommunications.com/ https://superioressexcommunications.com/ https://superioressexcommunications.com/ http://ce.superioressex.com/
All information, content, data, specifications, packaging and part numbers detailed herein are subject to change. For the most up-to-date information, please visit SuperiorEssexCommunications.com. Purchase of this product is subject exclusively to the then current Superior Essex International LP Terms and Conditions of Sale for Communications Cable, Wire and Connectivity Products, which can be found on our website, SuperiorEssexCommunications.com, or provided to you upon request.
Providing Quality, Experience and Expertise Superior Essex has TL 9000 and ISO 9001:2001 certification in every communications productions facility, assuring a level of quality and consistency in both products and customer service. We also manufacture custom products with special requirements, so our Product Management team can quote and deliver unique designs that are tailored for your applications. Beyond our quality assurance, value, and flexibility, we guarantee on-time delivery of the products you request.
Premises Cable Superior Essex Premises cables offer better performance, higher quality, and the best overall value, saving you both time and money.
From our 10Gain® XP CAT 6A to our CAT 3 voice and data cables, to our Coaxial cables and our multimode and single mode optical fiber cables, we offer a broad portfolio of products that are essential for high-bandwidth applications.
Outside Plant Wire and Cable Superior Essex is one of the world’s leading producers of OSP copper wire and optical fiber communications cables. With more than 4,000 different designs available, including Broadband, Composite, Fiber, and Copper Wire. This extensive line of products serves virtually every application for direct burial, aerial, and high risk installations.
Wireless Wireless technology is becoming the primary communication method, so it is crucial to choose products that have exceptional quality and performance, allowing for better coverage and capacity.
All of our Radio Frequency (RF) transmission and Distributed Antenna Systems (DAS) products provide an all-encompassing selection for the growing demands of wireless expansion for commercial wireless cell tower and in-building infrastructures.
http://ce.superioressex.com/ https://superioressexcommunications.com/
All information, content, data, specifications, packaging and part numbers detailed herein are subject to change. For the most up-to-date information, please visit SuperiorEssexCommunications.com. Purchase of this product is subject exclusively to the then current Superior Essex International LP Terms and Conditions of Sale for Communications Cable, Wire and Connectivity Products, which can be found on our website, SuperiorEssexCommunications.com, or provided to you upon request.
TA
BLE O
F CO
N
TEN
TS
PREM
ISES CA
BLE
O
SP CA
BLE
W
IRELESS
TECH
N
ICA
L IN
FO
PA
RT N
U
M
BER IN
D
EX
Table of Contents
Premises Fiber cable Simplex, Duplex and Quad Interconnect OFNR/OFNP . . . . . . . . . . . . . .A-2 MicroLite® Data Center Interconnect & Distribution OFNP . . . . . . . . .A-4 Microarray Data Center Interconnect OFNR/OFNP. . . . . . . . . . . . . . . . .A-6 2 mm Microarray Breakout OFNP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-8 Interlock Armored, 2 mm Microarray Breakout OFCP . . . . . . . . . . . . . .A-10 3 mm Microarray Breakout OFNR/OFNP . . . . . . . . . . . . . . . . . . . . . . . . . .A-12 Interlock Armored, 3 mm Microarray Breakout OFCR/OFCP . . . . . . . .A-14 EnduraLite® Indoor/Outdoor, Loose Tube OFNR/OFNP. . . . . . . . . . . . .A-16 EnduraLite® Indoor/Outdoor, Loose Tube, Interlock Armored OFCR/OFCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-18 Breakout OFNR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-20 Single Unit Distribution OFNR/OFNP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-22 Multi-Unit Distribution OFNR/OFNP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-24 Interlock Armored, Tight Buffer OFCR/OFCP . . . . . . . . . . . . . . . . . . . . . .A-26 Ribbon Distribution OFNR/OFNP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-28 Compact and Rugged Indoor MDU OFNR. . . . . . . . . . . . . . . . . . . . . . . . .A-30 Rugged Indoor/Outdoor MDU OFNR . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-31 Dry Block, Sunlight Resistant, Indoor/Outdoor, Tight Buffer OFNR. .A-32 Dry Block, Sunlight Resistant, Indoor/Outdoor OFNP . . . . . . . . . . . . . .A-34 Indoor/Outdoor, Interlock Armored, Tight Buffer OFCR/OFCP . . . . . .A-36 Composite (formerly Hybrid) OFNR/OFNP . . . . . . . . . . . . . . . . . . . . . . . .A-38 PowerWise® Fiber CL3R-OF/CL3P-OF, CMR-OF/CMP-OF and FPLR-OF/FPLP-OF . . . . . . . . . . .A-40 PowerWise® CLT Fiber CL3P-OF, CMP-OF. . . . . . . . . . . . . . . . . . . . . . . . . .A-42 PowerWise® Indoor/Outdoor 2x2 Hybrid CL3R-OF/FPLR-OF Wet Location and CMR-OF . . . . . . . . . . . . . . . . . . . . . . . .A-44 PowerWise® Indoor/Outdoor Tight Buffer Fiber CL3R-OF, CMR-OF and FPLR-OF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-46
Premises composite cable Bundled Composite Category 6 CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-48 Bundled Composite Category 5e CMR. . . . . . . . . . . . . . . . . . . . . . . . . . . .A-49 Residential Broadband Riser Coax RG-6 Quad Shield, Category 6 and Optical Fiber. . . . . . . . . . . . . . . . . . .A-50 Residential Broadband Riser Coax RG-6 Quad Shield, Category 5e and Optical Fiber. . . . . . . . . . . . . . . . . .A-51
Premises Copper cable 10Gain® XP Category 6A CMR-LP/CMP-LP. . . . . . . . . . . . . . . . . . . . . . . .A-52 10Gain® + Category 6A CMR/CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-54 PowerWise® 10G 4PPoE CMP-LP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-56 10Gain® Category 6A CMR/CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-58 Category 6A U/FTP (STP) CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-60 Category 6A U/FTP (STP) with FEP Jacket CMP . . . . . . . . . . . . . . . . . .A-62 Category 6A F/UTP (ScTP) CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . . .A-64 Category 6A F/UTP (ScTP) CMP/CMX Indoor/Outdoor . . . . . . . . . .A-66 NextGain® Category 6eX CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-68 DataGain® Category 6+ CMR/CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-70 Category 6+ LSHF CMR-LSHF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-72 Category 6+ F/UTP (ScTP) CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . . .A-74 Category 6 CMR/CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-76 Category 6 CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-78 Category 6 with FEP Jacket CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-80 Category 6 CMR/CMX Outdoor Sunlight Resistant . . . . . . . . . . . . . . . . . . . .A-84 Category 6 CMR/CMX Outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-86 Category 6 Patch Cable CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-88 Category 6 Patch Cable CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-89 Cobra Category 5e+ CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-90 Category 5e+ F/UTP (ScTP) CMR/CMP . . . . . . . . . . . . . . . . . . . . . . . . . .A-92 PowerWise® 1G 4PPoE CMR-LP/CMP-LP . . . . . . . . . . . . . . . . . . . . . . . . . .A-94 PowerWise® 1G 4PPoE with FEP Jacket CMP-LP Indoor/Outdoor. . . . .A-96 PowerWise® 1G 4PPoE Indoor/Outdoor CMR/CMX Sunlight Resistant . .A-98 PowerWise® 1G 4PPoE Indoor/Outdoor CMR/CMX . . . . . . . . . . . . . . . . .A-100 PowerWise® 1G 4PPoE CMR-LSHF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-102 Marathon LAN® Category 5e CMR/CMP. . . . . . . . . . . . . . . . . . . . . . . . . .A-104
Premises Copper cable Continued… Marathon LAN® Category 5e with FEP Jacket CMP Indoor/Outdoor. .A-106 Category 5e CM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-109 Category 5e CMR/CMX Outdoor Sunlight Resistant. . . . . . . . . . . . . . . . . . .A-110 Category 5e CMR/CMX Outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-112 Category 5e F/UTP (ScTP) CMR/CMX Outdoor Sunlight Resistant. . . . .A-114 Category 5e F/UTP (ScTP) CMR/CMX Outdoor . . . . . . . . . . . . . . . . . . . .A-116 6-Pair Category 5e CMR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-118 25-Pair Power Sum Category 5e CMR/CMP . . . . . . . . . . . . . . . . . . . . . . .A-119 25-Pair Category 5e Indoor/Outdoor . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-120 Interlock Armored Premises Copper CMR . . . . . . . . . . . . . . . . . . . . . . . . . .A-121 Bundled Category 6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-122 Bundled Category 5e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-123 EnduraGain® OSP Unshielded Formerly BBD . . . . . . . . . . . . . . . . . . . . . . .A-124 EnduraGain® OSP Shielded Formerly BBDN . . . . . . . . . . . . . . . . . . . . . . . .A-125 EnduraGain® OSP Armored Formerly BBDG . . . . . . . . . . . . . . . . . . . . . . . .A-126 EnduraGain® OSP Shielded Indoor/Outdoor Halogen-Free CM | Formerly BBDN I/O. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-128 EnduraGain® OSP Armored Indoor/Outdoor Halogen-Free CM | Formerly BBDG I/O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-129 EnduraGain® OSP Duplex Formerly OSP Broadband Duplex . . . . . . . . . . .A-130 MEGAPIC® OSP Broadband Backbone Category 5 . . . . . . . . . . . . . . . .A-131 Category 3 CMR/CMP 2-Pair – 400-Pair . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-132 Category 3 Station Wire CMR/CMX Outdoor . . . . . . . . . . . . . . . . . . . . . .A-134 ARMM Series CMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-136 Coax RG-11, Quad Shield CMR, CMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-138 Coax RG-11, 95% Shield CMR, CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-140 Coax RG-6, Quad Shield CM, CMR, CMP . . . . . . . . . . . . . . . . . . . . . . . . . .A-142 Coax RG-6, 95% Shield CMR, CMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-144 Coax RG-6, Tri-Shield 70% CM, CMR. . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-145 Coax RG-6, 60% Shield CM, CMG, CMP . . . . . . . . . . . . . . . . . . . . . . . . . .A-146 Coax RG-59, 95% Shield CMR, CMP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-148 Coax RG-59, 95% Shield + 18/2 CMR, CMP . . . . . . . . . . . . . . . . . . . . . .A-150 Fire Alarm, Non-Shielded Power Limited, Riser/Plenum . . . . . . . . . . . . . .A-152 Fire Alarm, Shielded Power Limited, Riser/Plenum . . . . . . . . . . . . . . . . . . .A-154 Interlock Armored Fire Alarm Riser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-156 Security Control, Non-Shielded Power Limited, Riser/Plenum . . . . . . . . .A-158 Security Control, Shielded Power Limited, Riser/Plenum . . . . . . . . . . . . . .A-160 Access Control Composite Riser/Plenum . . . . . . . . . . . . . . . . . . . . . . . . . .A-162
Central Office copper cable ABAM (600B) and ABMM Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-164 1249C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-165 1161A Series Category 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-166 600C Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-167 25-Pair Category 5e Shielded CMR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-168 Switchboard 100 Ohm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-170 Switchboard 100 Ohm 200A/800A Series (Canadian Color Code) . . . . . .A-172 T100 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-173 Switchboard 85 and Shielded Switchboard 85 . . . . . . . . . . . . . . . . . . . .A-174 Distribution Frame Wire DFW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-175 Heavy Duty Distribution Frame Wire HD-DFW . . . . . . . . . . . . . . . . . . . .A-176 Tight Twist Distribution Frame Wire DFW . . . . . . . . . . . . . . . . . . . . . . . .A-177 http://ce.superioressex.com/ https://superioressexcommunications.com/
All information, content, data, specifications, packaging and part numbers detailed herein are subject to change. For the most up-to-date information, please visit SuperiorEssexCommunications.com. Purchase of this product is subject exclusively to the then current Superior Essex International LP Terms and Conditions of Sale for Communications Cable, Wire and Connectivity Products, which can be found on our website, SuperiorEssexCommunications.com, or provided to you upon request.
TA
BL
E O
F
CO
N
TE
N
TS
PR
EM
IS
ES
C A
BL
E
O
SP
C A
BL
E
W
IR
EL
ES
S
TE
CH
N
IC
A
L
IN
FO
PA
RT
N
U M
BE
R
IN
D
EX
OSP Fiber cable Dri-Lite® Loose Tube Single Jacket All Dielectric Series 11D . . . . . . . .B-2 Dri-Lite® Loose Tube Double Jacket Non-Armor Series 1GD . . . . . . . .B-3 Dri-Lite® Loose Tube Single Jacket Single Armor Series 12D . . . . . . . .B-4 Dri-Lite® Loose Tube Double Jacket Single Armor Series 1AD . . . . . .B-5 Dri-Lite® Loose Tube Double Jacket Double Armor Series 1DD . . . . .B-6 Dri-Lite® Loose Tube Triple Jacket Double Armor Series 1CD . . . . . . .B-7 Loose Tube Single Jacket All Dielectric Series 11 . . . . . . . . . . . . . . . . . .B-8 Loose Tube Double Jacket Non-Armor Series 1G . . . . . . . . . . . . . . . . . .B-9 Loose Tube Single Jacket Single Armor Series 12 . . . . . . . . . . . . . . . . . .B-10 Loose Tube Double Jacket Single Armor Series 1A . . . . . . . . . . . . . . . . .B-11 Loose Tube Double Jacket Double Armor Series 1D. . . . . . . . . . . . . . . .B-12 Loose Tube Triple Jacket Double Armor Series 1C . . . . . . . . . . . . . . . . .B-13 Dri-Lite® Loose Tube Single Jacket Self Support Series 11DM . . . . . . .B-14 Dri-Lite® Loose Tube Double Jacket Self Support Series 1GDM. . . . . .B-15 Dri-Lite® Loose Tube Single Jacket Single Armor Self Support Series 12DM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-16 Dri-Lite® Loose Tube Double Jacket Single Armor Self Support Series 1ADM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-17 Loose Tube Single Jacket Self Support Series 11M . . . . . . . . . . . . . . . . .B-18 Loose Tube Double Jacket Self Support Series 1GM . . . . . . . . . . . . . . . .B-19 Loose Tube Single Jacket Single Armor Self Support Series 12M . . . .B-20 Loose Tube Double Jacket Single Armor Self Support Series 1AM . . .B-21 Dri-Lite® Loose Tube Single Jacket Long-Span Self Support Series 11MLS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-22 EnduraSpan™ ADSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-23 Single Loose Tube All Dielectric Series 51 . . . . . . . . . . . . . . . . . . . . . . . . .B-32 Single Loose Tube Single Armor Series 52 . . . . . . . . . . . . . . . . . . . . . . . . .B-33 Single Flex Tube All Dielectric Series F1 . . . . . . . . . . . . . . . . . . . . . . . . . . .B-34 Single Flex Tube Single Armor Series F2. . . . . . . . . . . . . . . . . . . . . . . . . . .B-35 Flex Tube Locate Series FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-36 Ribbon Locate Series RM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-37 Loose Tube Single Jacket All Dielectric Nylon Series 1NY. . . . . . . . . . .B-38 Dri-Lite® Loose Tube Indoor/Outdoor OFNR Series 13D. . . . . . . . . . . .B-39 Loose Tube Indoor/Outdoor OFNR Series 13 . . . . . . . . . . . . . . . . . . . . . .B-40 Interlock Armored OSP Fiber OFCR Series 13I . . . . . . . . . . . . . . . . . . . . .B-41 Dri-Lite® Loose Tube Single Jacket All Dielectric I/O LSZH Series HZD. . . . B-42 Dri-Lite® Loose Tube Single Jacket Single Armor I/O LSZH Series HZA . . . B-43 Loose Tube Single Jacket All Dielectric Indoor/Outdoor LSZH Series HZD B-44 Loose Tube Single Jacket Single Armor Indoor/Outdoor LSZH Series HZA B-45 Single Loose Tube Indoor/Outdoor OFNR Series 53. . . . . . . . . . . . . . . . . .B-46 Heavy Duty Loose Tube OFNR Series 1H. . . . . . . . . . . . . . . . . . . . . . . . . . .B-47 Telco Hybrid Loose Tube, Single 12 AWG Stranded Conductor Series 1N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-48 UG FTTP Series 513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-49 Buried FTTP, Steel Armor Series 52S. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-50 Buried FTTP, Steel Armor Series 52U . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-51 Figure 8 FTTP Series 573Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-52 Buried FTTP, Aluminum Armor Series 523 . . . . . . . . . . . . . . . . . . . . . . . .B-53 Telco Hybrid Buried Drop, Aluminum Armor Series 72 . . . . . . . . . . . . .B-54 Telco Hybrid Buried Drop, Steel Armor Series 72S . . . . . . . . . . . . . . . . .B-55 Universal Drop FTTP Series 6U . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-56 Toneable Drop FTTP Series 6T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-57 Universal FTTP Tight Buffered Indoor/Outdoor Drop Series W7U . . .B-58 Toneable FTTP Tight Buffered Indoor/Outdoor Drop Series W7T. . . .B-59 W7 Fiber Drop Assemblies Series ADWSA . . . . . . . . . . . . . . . . . . . . . . . .B-60 FTTP Tight Buffered Indoor/Outdoor Round Drop Series WR . . . . . . .B-61 Dri-Lite® Ribbon Series R1D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-62 Dri-Lite® Ribbon Single Armor Series R2D. . . . . . . . . . . . . . . . . . . . . . . . .B-63 Stranded Loose Tube Ribbon Single Jacket All Dielectric Series S1 . .B-64 Stranded Loose Tube Ribbon Single Armor Series S2 . . . . . . . . . . . . . . .B-66 Single Tube Ribbon Series R1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-67 Single Tube Ribbon Single Armor Series R2. . . . . . . . . . . . . . . . . . . . . . . .B-68 MicroLite™ OSP Air Blown LT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-69
OSP Hybrid cable Telco Hybrid Right of Way Series MR . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-70 Telco Hybrid Line Powering Series MR . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-71 Telco Hybrid Web Drop, Category 5e & OSP Fiber Series 5F. . . . . . . .B-72 Telco Hybrid Web Drop, OSP Copper & Fiber Series 5W . . . . . . . . . . .B-73 Telco Hybrid Overjacket Drop, OSP Copper & Fiber Series 71 OJ . . . .B-74 Telco Hybrid Web OSP Series 5V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-75 Telco Hybrid Overjacket OSP Series 70 OJ. . . . . . . . . . . . . . . . . . . . . . . . .B-76 Telco Hybrid Loose Tube, Stranded 24AWG Copper Pairs Series L . .B-77 PowerWise® Hybrid Series DE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-78
RDUP/RUS OSP Copper cable POWERPIC™ OSP Copper Cable for Line Powering. . . . . . . . . . . . . . . . . . . .B-79 SEALPIC®. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-80 SEALPIC®–84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-82 SEALPIC®–FSF-84 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-84 SEALPIC®–FSF RDUP PE-89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-86 CASPIC®–FSF RDUP PE-89 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-88 SEALPIC®–F RDUP PE-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-90 CUPIC–F® RDUP PE-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-92 GOPIC®–F RDUP PE-39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-94
Bell OSP Copper cable ALPETH BHBA, BHAA, BKMA and BKTA . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-96 PASP BHBH, BHAH, BKMH and BKTH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-98 Self-Support BHAS and BKMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-100 Reinforced Self-Support BHAP, BKMP and BKTP. . . . . . . . . . . . . . . . . . . . .B-101 Bonded STALPETH DCAZ, DCMZ and DCTZ. . . . . . . . . . . . . . . . . . . . . . . .B-102 STEAMPETH DKTN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-104 Power Station High Potential Filled ASP CMAW . . . . . . . . . . . . . . . . . . .B-105 Filled ALPETH ANBA, ANAA, ANMA and ANTA . . . . . . . . . . . . . . . . . . . . .B-106 Filled ASP ANBW, ANAW, ANMW and ANTW. . . . . . . . . . . . . . . . . . . . . . .B-108 T-SCREEN® Filled ASP KNAW and KHAH . . . . . . . . . . . . . . . . . . . . . . . . . .B-111
Canadian OSP Copper cable CELFIL BJBB, BJAB, BJMB and BJTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-112 Canadian ALPETH BHBB, BHAB, BKMB and BKTB. . . . . . . . . . . . . . . . . . . .B-114 SEALPAP BHBF, BHAF, BKMF and BKTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-116 Canadian Bonded STALPETH DCAZ, DCMZ and DCTZ . . . . . . .
This is the start of the file's text. The full file is on GovTribe.