S02 - Attachment 6(f) - Mechanical Cut Sheets - 2.0 Ton Split System.pdf
PDF 3 MB Posted
- Attached to
- EHRM San Antonio Infrastructure Upgrades Construction (SDVOSB Set-Aside and 236220 NAICS) Federal contract opportunity
- Solicitation number
- 36C77623B0064
About this file
This document contains mechanical cut sheets and specifications for a 2-ton split system air conditioning unit. Key details include specifications for both the indoor and outdoor units, such as dimensions, BTU/hour cooling and heating capacity, SEER rating, sound levels, voltage requirements, refrigerant type and quantity, and piping specifications. Accessories that can be purchased for each unit are also outlined. The split system is suitable for installation in spaces such as server rooms, daycares, classrooms, churches, and small offices.
View the file
Other files for this federal contract opportunity
Show all 50
EHRM San Antonio Infrastructure Upgrades Construction (SDVOSB Set-Aside and 236220 NAICS) has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Specifi cations are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Job Name:
System Reference: Date:
Indoor Unit PKA-A24KA7
Outdoor Unit PUY-A24NHA7
INDOOR UNIT FEATURES
• Sleek, compact design
• Simple installation
• Vane setting for air fl ow direction control
• Auto fan speed mode
• Ideal for spaces such as server rooms, daycare centers, classrooms, churches, small offi ces, and more
• Multiple control options available:
○ kumo cloud® smart device app for remote access
○ Third-party interface options
○ Wired or wireless controllers
OUTDOOR UNIT FEATURES
• Variable speed INVERTER-driven compressor
• Pre-charged with refrigerant volume for piping length up to 70 ft
• Low ambient cooling down to -40°F providing 100% capacity (with wind baffl es)
• 24-hour continuous operation (cooling mode)
• High pressure protection
• Fast restart
• Superior energy and operational effi ciency
• Seacoast protection*
○ External Outer Panel: Phosphate coating + Acrylic-Enamel coating
○ Fan Motor Support: Epoxy resin coating (at edge face)
○ Separator Assembly Valve Bed: Epoxy resin coating (at edge face)
○ Blue Fin treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.
○ Condenser coil and base panel rated for 2,000 hours in accordance with ASTM B117 testing
*Seacoast protection standard from 2022 production
PKA-A24KA7 & PUY-A24NHA7
24,000 BTU/H WALL-MOUNTED INDOOR UNIT
24,000 BTU/H COOLING ONLY OUTDOOR
Brandon.S.Garbrecht Text Box EHRM Infrastructure Upgrades –San Antonio, TX / VA Project # 671-22-700
Brandon.S.Garbrecht Text Box
2.0 Ton Split System
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7
test
Cooling at 95°F1
Maximum Capacity BTU/H 24,000 Rated Capacity BTU/H 24,000 Minimum Capacity BTU/H 10,000 Maximum Power Input W 1,960 Rated Power Input W 1,960 Moisture Removal Pints/h 5.0 Sensible Heat Factor 0.77 Power Factor [208V / 230V] % 95.7 / 95.7
Efficiency
SEER 21.4
EER1 12.2
ENERGY STAR® Certified No
Electrical
Voltage, Phase, Frequency 208/230, 1, 60 Guaranteed Voltage Range V AC 198 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208/230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating [SCCR] kA 5 Recommended Fuse/Breaker Size (Oudoor) A 25 Recommended Wire Size [Indoor - Outdoor] AWG 14 Power Supply Indoor unit is powered by the outdoor unit
Indoor Unit
MCA A 1.0
Fan Motor Full Load Amperage A 0.36 Fan Motor Type DC Motor Airflow Rate at Cooling, Dry CFM 635–705–775 Airflow Rate at Cooling, Wet CFM 570–635–700 Airflow Rate at Heating, Dry CFM 635–705–775 Sound Pressure Level [Cooling] dB[A] 39–42–45 Sound Pressure Level [Heating] dB[A] 39–42–45 Drain Pipe Size In. [mm] 5/8 [16] Coating on Heat Exchanger — External Finish Color White Munsell 1.0Y 9.2/0.2 Unit Dimensions W x D x H: In. [mm] 46-1/16 x 11-5/8 x 14-3/8 [1,170 x 295 x 365] Package Dimensions W x D x H: In. [mm] 51 x 14-1/4 x 18-1/2 [1,295 x 362 x 470] Unit Weight Lbs. [kg] 46 [21] Package Weight Lbs. [kg] 53 [24]
Indoor Unit Operating Temperature Range Cooling Intake Air Temp [Maximum / Minimum]* °F 90 DB, 72 WB / 66 DB, 61 WB
Outdoor Unit
MCA A 19.0
MOCP A 26
Fan Motor Full Load Amperage A 0.4 Fan Motor Output W 86 Airflow Rate [Cooling / Heating] CFM 1940 Refrigerant Control LEV Defrost Method Reverse Cycle Coating on Heat Exchanger Blue Fin Coating*** Sound Pressure Level, Cooling1 dB(A) 47 Compressor Type INVERTER-driven twin rotary Compressor Model SNB172FWHM1 Compressor Rated Load Amps A 7 Compressor Locked Rotor Amps A 11.0 Compressor Oil [Type // Charge] oz. FV50S // 23 External Finish Color Ivory Munsell 3Y 7.8/1.1 Base Pan Heater N/A Unit Dimensions W x D x H: In. [mm] 37-13/32 x 13 (+1-3/16) x 37-1/8 [950 x 330 (+30) x 943] Package Dimensions W x D x H: In. [mm] 40-15/16 x 17-11/16 x 40-11/16 [1040 x 450 x 1033] Unit Weight Lbs. [kg] 151 [68] Package Weight Lbs. [kg] 176 [80]
Outdoor Unit Operating Temperature Range Cooling Air Temp [Maximum / Minimum]* °F 115 DB / -40 DB
Refrigerant
Type R410A Maximum Charge Quantity Lbs, oz 7.0, 11.0 Initial Charge Quantity Ft. [m] 70.0 [20.0] Additional Refrigerant Charge Per Additional Piping Length oz./Ft. [g/m] 0.3 [22.5]
NOTES:
AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Wind baffles required to operate below 23°F DB in cooling mode.
• Cooling-only system with advanced wind baffle: -40°F - 115°F.
• Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
***Blue Fin Coating Standard from 2022 production:
• PU(Y/Z)-A(12/18)NKA7 - Beginning with serial number 12U*****
• PU(Y/Z)-A(24/30/36/42)NKA7 - Beginning with serial number 1ZU*****
SPECIFICATIONS: PKA-A24KA7 & PUY-A24NHA7
test
Piping
Gas Pipe Size O.D. [Flared] In.[mm] 5/8 [15.88] Liquid Pipe Size O.D. [Flared] In.[mm] 3/8 [9.52] Maximum Piping Length Ft. [m] 225 [68] Maximum Height Difference Ft. [m] 100 [30] Maximum Number of Bends 15
NOTES:
AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB
*Indoor/Outdoor Unit Operating Temperature Range (Cooling Air Temp [Maximum / Minimum]):
• Wind baffles required to operate below 23°F DB in cooling mode.
• Cooling-only system with advanced wind baffle: -40°F - 115°F.
• Refer to wind baffle documentation for further information.
**Outdoor Unit Operating Temperature Range (Cooling Thermal Lock-out / Re-start Temperatures; Heating Thermal Lock-out / Re-start Temperatures):
• System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.
***Blue Fin Coating Standard from 2022 production:
• PU(Y/Z)-A(12/18)NKA7 - Beginning with serial number 12U*****
• PU(Y/Z)-A(24/30/36/42)NKA7 - Beginning with serial number 1ZU*****
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
INDOOR UNIT ACCESSORIES: PKA-A24KA7
Control Interface
3-Pin Connector PAC-715AD BACnet® and Modbus® Interface PAC-UKPRC001-CN-1 IT Extender PAC-WHS01IE-E kumo station® for kumo cloud® PAC-WHS01HC-E Thermostat Interface PAC-US445CN-1 USNAP Adapter PAC-WHS01UP-E Wireless Interface for kumo cloud® PAC-USWHS002-WF-2
Remote Sensor
Flush Mount Remote Temperature Sensor PAC-USSEN002-FM-1 Flush Mount Temperature Sensor PAC-USSEN001-FM-1 Remote Temperature Sensor PAC-SE41TS-E Wireless temperature and humitity sensor for kumo cloud® PAC-USWHS003-TH-1
Wired Remote Controller
Deluxe Wired MA Remote Controller† PAR-40MAAU Simple MA Remote Controller† PAC-YT53CRAU-J Touch MA Controller† PAR-CT01MAU-SB
Wireless Remote Controller kumo touch™ RedLINK™ Wireless Controller MHK2 Lockdown bracket for remote controller RCMKP1CB Wireless MA Receiver PAR-FA32MA-W Wireless MA Remote Controller PAR-FL32MA-E
Condensate
Blue Diamond (Advanced) Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended] X87-721 Blue Diamond (MegaBlue Advanced) Condensate Pump w/ Reservoir & Sensor X87-835 Drain Pan Level Sensor/Control SS610E Refco Condensate Pump (100-240 VAC) GOBI-II Refco Condensate Pump (100-240 VAC) up to 120,000 BTU/H COMBI
Disconnect Switch (30A/600V/UL) [fits 2” X 4” utility box] - Black TAZ-MS303
Lineset
10’ x 3/8” x 10’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-10 100’ x 3/8” x 100’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-100 15’ x 3/8” x 15’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-15 30’ x 3/8” x 30’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-30 50’ x 3/8” x 50’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-50 65’ x 3/8” x 65’ x 5/8” Lineset (Twin-Tube Insulation) MPLS385812T-65
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
OUTDOOR UNIT ACCESSORIES: PUY-A24NHA7
Air Outlet Guide Air Outlet Guide (1 Piece) PAC-SG59SG-E
Centralized Drain Pan Centralized Drain Pan PAC-SG63DP-E Drain Pan PAC-SG64DP-E
Control/Service Tool
Control/Service Tool PAC-SK52ST M- & P-Series Maintenance Tool Cable Set M21EC0397 Maintenance Tool Interface PAC-USCMS-MN-1 USB/UART Conversion Cable (Required for all laptop connection) M21EC1397
Hail Guards Hail Guard HG-A6
M-NET Converter M-NET Converter PAC-SJ85MA-E M-NET Converter PAC-SJ95MA-E
Mini-Split Wire
14 Gauge, 4 wire MiniSplit Cable—250 ft. roll S144-250 14 Gauge, 4 wire MiniSplit Cable—50 ft. roll S144-50 16 Gauge, 4 wire MiniSplit Cable—250 ft. roll S164-250 16 Gauge, 4 wire MiniSplit Cable—50 ft. roll S164-50
Mounting Pad Condensing Unit Mounting Pad: 24” x 42” x 3” ULTRILITE2
Stand
18” Single Fan Stand QSMS1801M 24” Single Fan Stand QSMS2401M Condenser Wall Bracket QSWB2000M-1 Condenser Wall Bracket - Stainless Steel Finish QSWBSS Outdoor Unit Stand — 12” High QSMS1201M
Wind Baffle
Front Wind Baffle WB-PA5 Rear Wind Baffle WB-RE5 Side Advanced Wind Baffle WB-SD5
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Front side
46-1/16(1170) 9-1/2(241)33-21/32(855)2-29/32(74)
-3
/8 (3
Emergency operation switch (cooling/heating)
Terminal block for Outdoor unit
Terminal block for MA-remote controller
Front side(Grille open)
Terminal block for power supply (option)
Filter hook
6-1/16(154) 4-27/32(123)
18-31/32(482)Liquid pipe
17-15/32(444)Gas pipeDrain hose
5-9/32(134)
M in
.9 /3
2( 7)
Center measurement hole [ 3/32([ 2.5)
Knockout hole for rear piping
75-[ 3/16([ 5.1) Tapping screw hole
Mount board
Wall hole for right rear piping
Indoor unit outline
4-[ 11/32([ 9) Bolt hole
1/ 8(
3)
R1-15/32(R37.5)
2- 1/
8(
5/8(15.5)
-9
/3 2(
9)
0 17 -9
/3 2(
9)
-1
/8 (3
/3
2(
-3
/8 (5
.4
-7
/8 (4
-3
/3 2(
8.
5)
-1 /8
(3
-1 1/
(3
-3
/8 (3
4-
/3 2(
0)
2- 3/
8(
/3 2(
-5
/1 6(
5.
5)
-7 /8
(4
-3
/3 2(
8.
5)
-1 /8
(3
.5
-1
1/
(3
-3
/8 (3
4-
/3 2(
0)
2- 3/
8(
1-1/4(32)
12-5/32(308.5)
31/32(25)
11-1/2(292) 11(279.5)
9-17/32(242) 7-9/16(192)
5-19/32(142) 4-29/32(125) 4-19/32(117) 3-15/16(100) 2-15/16(75) 1-31/32(50)
-1
/8 (3
)0
-3
/4 (3
.2
-1
5/
(4
.5
1/2(12.5)
11-1/2(292) 10-13/32(264) 9-1/32(229.5) 8-17/32(217) 6-9/16(167) 5-3/32(129.5) 4-1/8(104.5) 3-7/16(87.5) 2-15/32(62.5) 1-15/32(37.5) 1/2(12.5)
2-1/8(54)
31/32(25)
12-1/4(311)
8-
/3 2(
6.
5)
-1
1/
(3
-7
/8 (5
.5
7- 7/
(1
-1
1/
(3
-1
1/
(4
.2
-1
/3 2(
5)
-1
/3 2(
5)
A
5/
(7 .8
3-
1/
(7 7)
2- 5/
8(
2-9/16(65)
B
Knockout hole for piping
13/32(10.7)
2- 9/
(6
5)
3-1/32(77) 3-7/16(87)
C
5/
(7 .8
2-9/16(65)
3- 1/
(7
7) 2-
5/ 8(
Louver(manual)Vane(auto)
Knockout hole for lower piping
Under side
BB
Receiver DEFROST/STAND BY lamp
Operation lamp
2-19/32(66)
/3
2(
1-
1/ 4(
2- 3/
(5
3)
1-3/16(30) 1-3/8(35)
Mount board
C
Knockout hole for right piping
Right side
11-5/8(295) 3/16(5)
Left side
A
Knockout hole for left piping
Top side
2- 9/
(6
5.
2)
5-
/3 2(
0.
3)
7/
(1 1)
17(431.7)16-11/16(423.7)
Air outlet
Air inlet
M in
.1 -7
/8 (4
8)
M in.
9-
/3 2(
0)
Required space(Indoor unit)
Min.3-31/32(100.5)Min.8-21/32(220)
Min.2-1/16(52.3)
3 2
Refrigerant pipe: 3/8 O.D([ 9.52)
Refrigerant pipe: 5/8 O.D([ 15.88)
5/8([ 16) O.D3 Drain hose
Piping connection
1 Liquid pipe
2 Gas pipeThrough hole
[ 2-15/16 ([ 75)
[ 2-15/16~[ 3-5/32 ([ 75~[ 80)
Sleeve (purchased locally) Flared connection: 5/8F
Flared connection: 3/8F
Effective length: 23-1/32 (585)
Unit: inch (mm)
INDOOR UNIT DIMENSIONS: PKA-A24KA7
FORM# PKA-A24KA7 & PUY-A24NHA7 - 202302
1340 Satellite Boulevard Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com
Specifications are subject to change without notice. © 2023 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.
Drain hole (5- ø33<1-5/16>)
Bottom piping hole (knockout)
<5-23/32>
<5-23/32>
<5-23/32>
<8-21/32>30 <1-3/16>
<3
-3 /1
6>
<8
-5 /8
71<2-13/16> 71 <2
-1 3/
Rear piping cover Front piping cover
2-12×36 oval holes (Foundation Bolt M10<W3/8>)
Air Discharge
Rear Air Intake
Side Air Intake
2-U Shaped notched holes (Foundfation Bolt M10<W3/8>)
Installation Feet
0<
175<6-7/8>
57<2-1/4> 41 <1-5/8>
<1 -1
/3 2>
<1
-3 /3
2>
0<
-9 /1
6>
<3
/4
<3
1/
70 <2-3/4>
175 <6-7/8> 600<23-5/8>
40<19/32>
53<2-3/32>
61<2-13/32>
Side Air Intake
Handle for moving
Air Intake
Rear Air Intake
Handle for moving
Min.100mm <3-15/16>
Min. 500mm <19-11/16>
Handle for moving
Handle for moving
Service panel Earth terminal
Left ... Power supply wiring Reight ... Indoor/Outdoor wiring
Terminal Connections
9<
-1
1/
950<37-13/32> 322<12-11/16>
<3 7-
1/ 8>
<1 8-
5/ 8>
<2
9/
*1
<1
7- 5/
8> *1
<1 6-
/3
2>
Min. 10mm <3/8>
Min. 10mm <3/8>
FR
EE
When installing the conduit, Set the attachment to the inner side of each panel.
1/2 Conduit attachment
2-ø22.2<7/8>
<1
-7 /3
2>
74<2-19/32>
40<1-9/16>
1 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)
... Refrigerant LIQUID pipe connection (FLARE) ø 9.52(3/8F) *1... Indication of STOP VALVE connection location.
Example of Notes
Power supply wiring hole (2- ø27<1-1/16>knockout) Rear trunking hole (knockout)
Rear piping hole (knockout)
<2
-1 /2
<2 -7
/1 8>
<2
9/
<2
-3 /1
6>
<1 -1
/1 6> 92<3-5/18>
65 <2-9/16>
45<1-25/32> 40<1-9/16> ø92 <3-5/8>
Power supply wiring hole (2-ø27knockout)
Front trunking hole (knockout)
Front piping hole (knockout)
45<1-25/32>
65<2-9/16> 92<3-5/8>
40<1-9/16>
<2
-1 /2
<2
9/
<2 -7
/8
<2
-3 /1
6>
<1 -1
/1 6>
92<3-5/8>
Right piping hole (knockout)
Right trunking hole (knockout)
Power supply wiring hole (2- ø27knockout)
19<3/4> 55 <2-3/16>
<2
9/
<1 -1
/1 6>
<3
-5 /8
92 <3-5/8>
40<1-9/16>75 <2-31/32>
<2
-7 /1
8>
<2 -1
/2
92<3-5/8>
Piping knockout Hole Details
Ma x.
<Foundation bolt height>
<1
-3 /1
6>
Min.
Mi n.
Service space
10 <13> Min.
500 <19-11/16>
<1
9-
/1 6>
<3 -1
5/
M in
Dimensions of space needed for service access are shown in the below diagram.
Please secure the unit firmly with 4 foundation (M10<W3/8>) bolts.
(Bolts and washers must be purchased locally.)
Piping and wiring connections can be made from 4 directions:
FRONT,Right,Rear and Below.
4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit)
The diagram below shows a basic example.
Explantion of particular details are given in the installation manuals etc.
ø ø
FOUNDATION
OUTDOOR UNIT DIMENSIONS: PUY-A24NHA7
File details come from the government source that posted it. Updated .