This document is a Bid Set package for the Camp Nelson National Cemetery Existing Condition Survey and Roadway Analysis project, prepared for the National Cemetery Administration. The project number is 833CM3030, with a bid set date of January 7, 2026.

The package contains comprehensive survey and design documentation including existing condition roadway analysis sheets (VF-201 through VF-204) prepared by SurvTech Solutions, Inc. using mobile LiDAR mapping and land surveying techniques. Field work was completed March 9, 2023, utilizing North American Datum 1983 (Kentucky North Zone, 2011 Adjustment) for horizontal control and North American Vertical Datum 1988 for vertical control. Subsurface utility engineering notes identify limitations in locating certain underground utilities and recommend test holes for verification. The survey explicitly states it is not a boundary survey and does not certify pavement condition interpretation. Supporting design documentation includes erosion and sediment control plans (CE-101, CE-102, CE-201) with sediment filter logs, inlet protection details, and temporary sediment check dams. Site demolition plans (CD-101, CD-102) detail full-depth pavement removal, curb removal, selective demolition of pavement, and utilities management including septic system components, drain inlets, and various infrastructure elements. Grading plans (CG-101) address wet pond conversion criteria and modifications to existing stormwater management structures. The project involves multiple work areas including the main cemetery road, maintenance access road, detention pond, and spoils area, with detailed keynotes and specifications for each demolition and construction phase.

View the file

Other files

File Type Posted
S06_36C78626R0058 Amend. 0003.pdf PDF
S02 Amendement 36C78626R0058 0002.pdf PDF
S02 amendment 2.pdf PDF
S02 Fire Alarm Panel.pdf PDF
S02 Liquidated Damages 833CM3030_CNNC FCA Corrections CONS.pdf PDF
S02 12 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_addendum01.pdf PDF
S02 Amendment 36C78626R0058 0001.pdf PDF
P07 Jessamine Camp Nelson Building.pdf PDF
S02_Price Proposal Breakdown.docx DOCX document
S02_Attachment - Past Performance Questionnaire.docx DOCX document
P07 Jessamine Camp Nelson Highway.pdf PDF
S02_Attachment - DOL Payroll Form.pdf PDF
S02 833CM3030_CNNC FCA Corrections_CONS_BD SPECIFICATIONS.pdf PDF
S02 08 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 10 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 04 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1 (1).pdf PDF
S02_Attachment - Standard Form 1413.pdf PDF
S02 02 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 07 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 06 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
P07 Jessamine Camp Nelson Heavy.pdf PDF
S02_Attachment - Davis-Bacon Act Poster.pdf PDF
S09 09 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 11 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 2_05212026 1.pdf PDF
S02 Camp Nelson Sol 36C78626R0058 draft 9-14-2026.pdf PDF
S02 05 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02 01 from 833CM3030_CNNC FCA Corrections_CONS_BD DRAWINGS_VOL 1_05212026 1.pdf PDF
S02_Attachment - Project Sample Template.docx DOCX document
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Survtech Solutions, Inc.

0 25 50 100 150

CAMP NELSON

EXISTING CONDITION SURVEY

ROADWAY ANALYSIS

VF-201

Land Surveying Permit Professional Land Surveyor Spot Elevation Spot Elevation on Hard Surface

Edge of Pavement Elevation Back of Curb Elevation

Grave Stone

Storm Manhole Catch Basin

Water Meter Cleanout Square Post

Irrigation Control Valve Corrugated Plastic Pipe Electric Transformer Pine Unknown Tree Fence Underground Water Line Underground Electric Line Underground Drainage Pipe Line Continues End of Information

SURVEYOR'S NOTES

1. Paper copies of this survey are not valid without the original signature and seal of a Kentucky Professional Land Surveyor.

Digital copies are not valid without the digital signature of a Kentucky Professional Land Surveyor.

2. The horizontal datum utilized for this project is North American Datum (NAD) 1983 Kentucky North Zone, 2011 Adjustment, U.S.

Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service (OPUS).

3. The vertical datum utilized for this project is North American Vertical Datum (NAVD) 1988, U.S. Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service

(OPUS).

4. The field work performed in support of this survey was completed by SurvTech, on March 9, 2023.

5. The surveyor only certifies the mobile LiDAR mapping and supporting land surveying, not the interpretation of pavement conditions.

6. Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field.

7. THIS IS NOT A BOUNDARY SURVEY.

SUBSURFACE UTILITY ENGINEERING NOTES

A. ARV for water main.

B. Unable to locate underground electric line continuation.

C. Unable to locate water main with EM or GPR methods.

D. GPR was limited to 1.5' depth due to ground conditions.

E. Test holes are recommended to verify the locations of underground utilities.

G. Unable to locate underground power coming off generator with

EM or GPR methods.

H. Unable to trace water valves and spigots to main with EM or

GPS.

V F -2

V F -2

VF-202

VF-203

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

NWG

NOT TO SCALE

KEY

Bid Set DateDateDate

JANUARY 7, 2026

AutoCAD SHX Text

TBM #1

AutoCAD SHX Text

TBM #2

AutoCAD SHX Text http://www.survtechsolutions.com

AutoCAD SHX Text Land Surveying Permit No. 712

AutoCAD SHX Text fax: (813)-621-7194

AutoCAD SHX Text Tampa, FL 33610

AutoCAD SHX Text 10220 U.S. Highway 92 East

AutoCAD SHX Text phone: (813)-621-4929

AutoCAD SHX Text email: dobrien@survtechsolutions.com

AutoCAD SHX Text David J. O'Brien Jr. PLS No. 3910

AutoCAD SHX Text SurvTech Solutions, Inc. LSP No. 712

AutoCAD SHX Text

LSP

AutoCAD SHX Text

PLS

AutoCAD SHX Text X.X

AutoCAD SHX Text

X.XX

AutoCAD SHX Text Address: 6980 Danville Road City: Nicholasville County: Jessamine State: Kentucky

AutoCAD SHX Text Scale: 1" = 50'

AutoCAD SHX Text

XX.XX

AutoCAD SHX Text

XX.XX

AutoCAD SHX Text W

AutoCAD SHX Text

CO

AutoCAD SHX Text C

AutoCAD SHX Text

CPP

AutoCAD SHX Text X

AutoCAD SHX Text D

AutoCAD SHX Text X

AutoCAD SHX Text

UW

AutoCAD SHX Text

UW

AutoCAD SHX Text

UE

AutoCAD SHX Text

UE

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text TBM #1 Set Capped Iron Rod labeled "SurvTech Trav. Pt" locate 52 feet Southeast of concrete pad with transformer and 35 feet Northeast of North building corner. Elevation = 874.83' TBM #2 Set nail & disk labeled "SurvTech Trav. Pt" located 8 feet east of inlet D-15 and 3' North of D-curb. Elevation = 899.99'

AutoCAD SHX Text Benchmark Information: NGVD 1929

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

AutoCAD SHX Text

CONSULTANTS

0 10 20 40 60SEE SHEET VF-203

A. ARV for water main.

B. Unable to locate underground electric line continuation.

C. Unable to locate water main with EM or GPR methods.

D. GPR was limited to 1.5' depth due to ground conditions.

E. Test holes are recommended to verify the locations of underground utilities.

G. Unable to locate underground power coming off generator with

EM or GPR methods.

H. Unable to trace water valves and spigots to main with EM or

GPS.

Storm Structure Table:

Survtech Solutions, Inc.

CAMP NELSON

EXISTING CONDITION SURVEY

ROADWAY ANALYSIS

SURVEYOR'S NOTES

1. Paper copies of this survey are not valid without the original signature and seal of a Kentucky Professional Land Surveyor.

Digital copies are not valid without the digital signature of a Kentucky Professional Land Surveyor.

2. The horizontal datum utilized for this project is North American Datum (NAD) 1983 Kentucky North Zone, 2011 Adjustment, U.S.

Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service (OPUS).

3. The vertical datum utilized for this project is North American Vertical Datum (NAVD) 1988, U.S. Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service

(OPUS).

4. The field work performed in support of this survey was completed by SurvTech, on March 9, 2023.

5. The surveyor only certifies the mobile LiDAR mapping and supporting land surveying, not the interpretation of pavement conditions.

6. Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field.

7. THIS IS NOT A BOUNDARY SURVEY.

SUBSURFACE UTILITY ENGINEERING NOTES

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

NWG

NOT TO SCALE

KEY

VF-202

Land Surveying Permit Professional Land Surveyor Spot Elevation Spot Elevation on Hard Surface

Edge of Pavement Elevation Back of Curb Elevation

Grave Stone

Storm Manhole Catch Basin

Water Meter Cleanout Square Post

Irrigation Control Valve Corrugated Plastic Pipe Electric Transformer Pine Unknown Tree Fence Underground Water Line Underground Electric Line Underground Drainage Pipe Line Continues End of Information

Bid Set DateDateDate

JANUARY 7, 2026

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text Storm Inlet (D-2)

AutoCAD SHX Text Storm Inlet (D-1)

AutoCAD SHX Text Grate Inlet (D-6)

AutoCAD SHX Text Drain Inlet (D-3)

AutoCAD SHX Text Drain Inlet (D-4)

AutoCAD SHX Text Grate Inlet (D-7)

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

24" CPP

AutoCAD SHX Text

24" CPP

AutoCAD SHX Text

24" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Grate Inlet (D-9)

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Grate Inlet (D-8)

AutoCAD SHX Text Grate Inlet (D-10)

AutoCAD SHX Text Concrete

AutoCAD SHX Text G R A S S

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete Decorative Memorial

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text Road A (Asphalt Pavement)

AutoCAD SHX Text Road B (Asphalt Pavement)

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text Scale: 1" = 20'

AutoCAD SHX Text TBM #1 Set Capped Iron Rod labeled "SurvTech Trav. Pt" locate 52 feet Southeast of concrete pad with transformer and 35 feet Northeast of North building corner. Elevation = 874.83' TBM #2 Set nail & disk labeled "SurvTech Trav. Pt" located 8 feet east of inlet D-15 and 3' North of D-curb. Elevation = 899.99'

AutoCAD SHX Text Benchmark Information: NGVD 1929

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

AutoCAD SHX Text

CONSULTANTS

AutoCAD SHX Text http://www.survtechsolutions.com

AutoCAD SHX Text Land Surveying Permit No. 712

AutoCAD SHX Text fax: (813)-621-7194

AutoCAD SHX Text Tampa, FL 33610

AutoCAD SHX Text 10220 U.S. Highway 92 East

AutoCAD SHX Text phone: (813)-621-4929

AutoCAD SHX Text email: dobrien@survtechsolutions.com

AutoCAD SHX Text

LSP

AutoCAD SHX Text

PLS

AutoCAD SHX Text X.X

AutoCAD SHX Text

X.XX

AutoCAD SHX Text

XX.XX

AutoCAD SHX Text W

AutoCAD SHX Text

CO

AutoCAD SHX Text C

AutoCAD SHX Text

CPP

AutoCAD SHX Text X

AutoCAD SHX Text D

AutoCAD SHX Text X

AutoCAD SHX Text

UW

AutoCAD SHX Text

UW

AutoCAD SHX Text

UE

AutoCAD SHX Text

UE

AutoCAD SHX Text D

AutoCAD SHX Text D

XX.XX

0 10 20 40 60

S E E S

H E E T V

F -2

S E E S

H E E T V

F -2

Storm Structure Table:

Survtech Solutions, Inc.

CAMP NELSON

EXISTING CONDITION SURVEY

ROADWAY ANALYSIS

SURVEYOR'S NOTES

1. Paper copies of this survey are not valid without the original signature and seal of a Kentucky Professional Land Surveyor.

Digital copies are not valid without the digital signature of a Kentucky Professional Land Surveyor.

2. The horizontal datum utilized for this project is North American Datum (NAD) 1983 Kentucky North Zone, 2011 Adjustment, U.S.

Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service (OPUS).

3. The vertical datum utilized for this project is North American Vertical Datum (NAVD) 1988, U.S. Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service

(OPUS).

4. The field work performed in support of this survey was completed by SurvTech, on March 9, 2023.

5. The surveyor only certifies the mobile LiDAR mapping and supporting land surveying, not the interpretation of pavement conditions.

6. Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field.

7. THIS IS NOT A BOUNDARY SURVEY.

SUBSURFACE UTILITY ENGINEERING NOTES

A. ARV for water main.

B. Unable to locate underground electric line continuation.

C. Unable to locate water main with EM or GPR methods.

D. GPR was limited to 1.5' depth due to ground conditions.

E. Test holes are recommended to verify the locations of underground utilities.

G. Unable to locate underground power coming off generator with

EM or GPR methods.

H. Unable to trace water valves and spigots to main with EM or

GPS.

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

NWG

NOT TO SCALE

KEY

VF-203

Land Surveying Permit Professional Land Surveyor Spot Elevation Spot Elevation on Hard Surface

Edge of Pavement Elevation Back of Curb Elevation

Grave Stone

Storm Manhole Catch Basin

Water Meter Cleanout Square Post

Irrigation Control Valve Corrugated Plastic Pipe Electric Transformer Pine Unknown Tree Fence Underground Water Line Underground Electric Line Underground Drainage Pipe Line Continues End of Information

Bid Set DateDateDate

JANUARY 7, 2026

AutoCAD SHX Text Drain Inlet (D-4)

AutoCAD SHX Text Grate Inlet (D-7)

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

8" CPP

AutoCAD SHX Text

AutoCAD SHX Text Drain Inlet (D-12)

AutoCAD SHX Text Drain Inlet (D-5)

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Drain Inlet (D-13)

AutoCAD SHX Text Drain Inlet (D-14)

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Drain Inlet (D-15)

AutoCAD SHX Text

24" CPP

AutoCAD SHX Text

24" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Crushed Rocks

AutoCAD SHX Text Crushed Rocks

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text 4' Iron Bar Fence

AutoCAD SHX Text Top of Bank

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text Road A (Asphalt Pavement)

AutoCAD SHX Text W

AutoCAD SHX Text SUE Note "A"

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text

TBM #2

AutoCAD SHX Text Scale: 1" = 20'

AutoCAD SHX Text TBM #1 Set Capped Iron Rod labeled "SurvTech Trav. Pt" locate 52 feet Southeast of concrete pad with transformer and 35 feet Northeast of North building corner. Elevation = 874.83' TBM #2 Set nail & disk labeled "SurvTech Trav. Pt" located 8 feet east of inlet D-15 and 3' North of D-curb. Elevation = 899.99'

AutoCAD SHX Text Benchmark Information: NGVD 1929

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

AutoCAD SHX Text

CONSULTANTS

AutoCAD SHX Text http://www.survtechsolutions.com

AutoCAD SHX Text Land Surveying Permit No. 712

AutoCAD SHX Text fax: (813)-621-7194

AutoCAD SHX Text Tampa, FL 33610

AutoCAD SHX Text 10220 U.S. Highway 92 East

AutoCAD SHX Text phone: (813)-621-4929

AutoCAD SHX Text email: dobrien@survtechsolutions.com

AutoCAD SHX Text

LSP

AutoCAD SHX Text

PLS

AutoCAD SHX Text X.X

AutoCAD SHX Text

X.XX

AutoCAD SHX Text

XX.XX

AutoCAD SHX Text W

AutoCAD SHX Text

CO

AutoCAD SHX Text C

AutoCAD SHX Text

CPP

AutoCAD SHX Text X

AutoCAD SHX Text D

AutoCAD SHX Text X

AutoCAD SHX Text

UW

AutoCAD SHX Text

UW

AutoCAD SHX Text

UE

AutoCAD SHX Text

UE

AutoCAD SHX Text D

AutoCAD SHX Text D

0 10 20 40 60

S E E S

H E E T V

F -2

Storm Structure Table:

Survtech Solutions, Inc.

CAMP NELSON

EXISTING CONDITION SURVEY

ROADWAY ANALYSIS

SURVEYOR'S NOTES

1. Paper copies of this survey are not valid without the original signature and seal of a Kentucky Professional Land Surveyor.

Digital copies are not valid without the digital signature of a Kentucky Professional Land Surveyor.

2. The horizontal datum utilized for this project is North American Datum (NAD) 1983 Kentucky North Zone, 2011 Adjustment, U.S.

Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service (OPUS).

3. The vertical datum utilized for this project is North American Vertical Datum (NAVD) 1988, U.S. Survey Feet. Said datum was established by performing a rapid static GPS session and utilizing National Geodetic Survey's (NGS) Online Positioning User Service

(OPUS).

4. The field work performed in support of this survey was completed by SurvTech, on March 9, 2023.

5. The surveyor only certifies the mobile LiDAR mapping and supporting land surveying, not the interpretation of pavement conditions.

6. Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field.

7. THIS IS NOT A BOUNDARY SURVEY.

SUBSURFACE UTILITY ENGINEERING NOTES

A. ARV for water main.

B. Unable to locate underground electric line continuation.

C. Unable to locate water main with EM or GPR methods.

D. GPR was limited to 1.5' depth due to ground conditions.

E. Test holes are recommended to verify the locations of underground utilities.

G. Unable to locate underground power coming off generator with

EM or GPR methods.

H. Unable to trace water valves and spigots to main with EM or

GPS.

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

NWG

NOT TO SCALE

KEY

VF-204

Land Surveying Permit Professional Land Surveyor Spot Elevation Spot Elevation on Hard Surface

Edge of Pavement Elevation Back of Curb Elevation

Grave Stone

Storm Manhole Catch Basin

Water Meter Cleanout Square Post

Irrigation Control Valve Corrugated Plastic Pipe Electric Transformer Pine Unknown Tree Fence Underground Water Line Underground Electric Line Underground Drainage Pipe Line Continues End of Information

Bid Set DateDateDate

JANUARY 7, 2026

AutoCAD SHX Text 14"

AutoCAD SHX Text 18"

AutoCAD SHX Text 18"

AutoCAD SHX Text 14"

AutoCAD SHX Text 18"

AutoCAD SHX Text 18"

AutoCAD SHX Text 18"

AutoCAD SHX Text 20"

AutoCAD SHX Text 24"

AutoCAD SHX Text 26"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 7"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text 18"

AutoCAD SHX Text 10"

AutoCAD SHX Text 12"

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Drain Inlet (D-13)

AutoCAD SHX Text Drain Inlet (D-14)

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text Drain Inlet (D-15)

AutoCAD SHX Text Drain Inlet (D-16)

AutoCAD SHX Text

15" CPP

AutoCAD SHX Text

8" PVC

AutoCAD SHX Text

AutoCAD SHX Text

8" PVC

AutoCAD SHX Text Drain Inlet (D-18)

AutoCAD SHX Text Drain Inlet (D-17)

AutoCAD SHX Text

8" PVC

AutoCAD SHX Text

AutoCAD SHX Text 1 Story Brick Wood Frame Building Foot Print = 2348 SqFt FFE = 876.13' Building Height = 23.86'

AutoCAD SHX Text Metal Silo

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text 4' Iron Bar Fence

AutoCAD SHX Text 6' Chain Link Fecne

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete D Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Concrete A Curb

AutoCAD SHX Text Edge of Pavement

AutoCAD SHX Text Edge of Pavement

AutoCAD SHX Text Edge of Pavement

AutoCAD SHX Text 6' Chain Link Fecne

AutoCAD SHX Text Covered Car Port

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text Top of Bank

AutoCAD SHX Text Top of Bank

AutoCAD SHX Text Toe of Slope

AutoCAD SHX Text Top of Bank

AutoCAD SHX Text Rip Rap

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text G R A S S

AutoCAD SHX Text Road A (Asphalt Pavement)

AutoCAD SHX Text SUE Note "B"

AutoCAD SHX Text SUE Note "H"

AutoCAD SHX Text SUE Note "G"

AutoCAD SHX Text Water Pump

AutoCAD SHX Text 12"

AutoCAD SHX Text

TBM #1

AutoCAD SHX Text

TBM #2

AutoCAD SHX Text Scale: 1" = 20'

AutoCAD SHX Text TBM #1 Set Capped Iron Rod labeled "SurvTech Trav. Pt" locate 52 feet Southeast of concrete pad with transformer and 35 feet Northeast of North building corner. Elevation = 874.83' TBM #2 Set nail & disk labeled "SurvTech Trav. Pt" located 8 feet east of inlet D-15 and 3' North of D-curb. Elevation = 899.99'

AutoCAD SHX Text Benchmark Information: NGVD 1929

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

AutoCAD SHX Text

CONSULTANTS

AutoCAD SHX Text http://www.survtechsolutions.com

AutoCAD SHX Text Land Surveying Permit No. 712

AutoCAD SHX Text fax: (813)-621-7194

AutoCAD SHX Text Tampa, FL 33610

AutoCAD SHX Text 10220 U.S. Highway 92 East

AutoCAD SHX Text phone: (813)-621-4929

AutoCAD SHX Text email: dobrien@survtechsolutions.com

AutoCAD SHX Text

LSP

AutoCAD SHX Text

PLS

AutoCAD SHX Text X.X

AutoCAD SHX Text

X.XX

AutoCAD SHX Text

XX.XX

AutoCAD SHX Text W

AutoCAD SHX Text

CO

AutoCAD SHX Text C

AutoCAD SHX Text

CPP

AutoCAD SHX Text X

AutoCAD SHX Text D

AutoCAD SHX Text X

AutoCAD SHX Text

UW

AutoCAD SHX Text

UW

AutoCAD SHX Text

UE

AutoCAD SHX Text

UE

AutoCAD SHX Text D

AutoCAD SHX Text D

F

Ex. Curb

Ex. Curb

Ex. 8" Headwall

Ex. Gravel Drive

Ex. Gravel Drive

Ex. 8' Chainlink Fence

Ex. 8' ChainlinkFence

8" Wall8" Wall

Ex.

Ed ge of Gra vel

Gr av el

Gravel Gr av el

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. 6' Chain Link

Ex. 6' Chain Link

For Alignment Purposes Only (Typ.)

For A lignm ent P urposes O nly (Typ.)

941.88

940.32

940.16

Surveyor's Notes

SUE Notes

F

Ex. Curb

Ex. Curb

Ex. 8" Headwall

Ex. Gravel Drive

Ex. Gravel Drive

Ex. 8' Chainlink Fence

Ex. 8' ChainlinkFence

8" Wall8" Wall

Ex.

Ed ge of Gra vel

Gr av el

Gravel Gr av el

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. 6' Chain Link

Ex. 6' Chain Link

For Alignment Purposes Only (Typ.)

For A lignm ent P urposes O nly (Typ.)

941.88

940.32

940.16

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

NOT TO SCALE

KEY

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

EROSION & SEDIMENT

CONTROL PLAN

CE-101

SEDIMENT FILTER LOG 1

CE-201

CE-102

CE-102

CE-102

CE-102

CE-102

0 20 40 80 120

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 8"

AutoCAD SHX Text 1 Story Brick Wood Frame Building Foot Print = 2348 SqFt FFE = 876.13' Building Height = 23.86'

AutoCAD SHX Text Covered Car Port

AutoCAD SHX Text 942.34

AutoCAD SHX Text 941.97

AutoCAD SHX Text 942.12

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text Existing Section V

AutoCAD SHX Text Existing Section X

AutoCAD SHX Text Existing Section J

AutoCAD SHX Text B-1

AutoCAD SHX Text B-7

AutoCAD SHX Text B-2

AutoCAD SHX Text B-3

AutoCAD SHX Text B-8

AutoCAD SHX Text B-6

AutoCAD SHX Text B-5

AutoCAD SHX Text B-4

AutoCAD SHX Text

AutoCAD SHX Text 942.12

AutoCAD SHX Text

AutoCAD SHX Text 941.97

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 942.34

AutoCAD SHX Text

AutoCAD SHX Text 942.34

AutoCAD SHX Text

AutoCAD SHX Text 941.97

AutoCAD SHX Text

AutoCAD SHX Text 942.12

AutoCAD SHX Text 1.) Paper copies of this survey are not valid without the original signature and raised seal of a Paper copies of this survey are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper. Digital copies are not valid without the digital signature of a Florida Licensed Surveyor and Mapper. 2.) The horizontal datum utilized for this project is NAD 1983 Kentucky North Zone, 2011 The horizontal datum utilized for this project is NAD 1983 Kentucky North Zone, 2011 Adjustment, U.S. Survey Feet. Said datum was established by utilizing the Florida Permanent Reference Network (FPRN). 3.) The vertical datum utilized for this project is NAVD 1988, U.S. Survey Feet. Elevations were The vertical datum utilized for this project is NAVD 1988, U.S. Survey Feet. Elevations were established utilizing Opus 4.) As stipulated by state law, it is the contractor's responsibility to contact Sunshine State One As stipulated by state law, it is the contractor's responsibility to contact Sunshine State One Call of Florida at 1-800-432-4770 prior to conducting excavation. 5.) Markings for subsurface utilities have varying degrees of accuracies based on many different Markings for subsurface utilities have varying degrees of accuracies based on many different variables, such as but not limited to, high water table, soil conditions, and utility size and material. Always hand dig within 2-3 feet of any utilities or markings. 6.) All reasonable and commonly accepted techniques were applied to locating subsurface utilities All reasonable and commonly accepted techniques were applied to locating subsurface utilities as stipulated in the scope of work for this project, however, there may be other subsurface utilities and/or aboveground features not depicted hereon within the project limits. 7.) Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field. 8.) No underground foundations or footers were excavated or located for this survey. No underground foundations or footers were excavated or located for this survey. 9.) THIS IS NOT A BOUNDARY SURVEY.THIS IS NOT A BOUNDARY SURVEY.

AutoCAD SHX Text 1.) Test Holes are recommended to verify designation. Test Holes are recommended to verify designation. 2.) Due to soil conditions GPR could not see deeper than 3.00 feet. Due to soil conditions GPR could not see deeper than 3.00± feet.3.) All concrete was reinforced. 4.) Per Mike with Camp Nelson, the cleanouts shown hereon are for storm structures. Per Mike with Camp Nelson, the cleanouts shown hereon are for storm structures. 5.) Site is on a septic system. Site is on a septic system. "A" Valve found with no tracer wire, could not induce or see with GPR. Valve found with no tracer wire, could not induce or see with GPR. *Note* The crew spoke with a maintenance team member on site who informed them that there were no water calves to the water main on the property. there was no tracer wire and no valves were found going to any of the water spouts. only one water valve on could be found on site.

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text Existing Section V

AutoCAD SHX Text Existing Section X

AutoCAD SHX Text Existing Section J

AutoCAD SHX Text B-1

AutoCAD SHX Text B-7

AutoCAD SHX Text B-2

AutoCAD SHX Text B-3

AutoCAD SHX Text B-8

AutoCAD SHX Text B-6

AutoCAD SHX Text B-5

AutoCAD SHX Text B-4

AutoCAD SHX Text

AutoCAD SHX Text 942.12

AutoCAD SHX Text

AutoCAD SHX Text 941.97

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 942.34

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

AutoCAD SHX Text

CONSULTANTS

AutoCAD SHX Text

SL

AutoCAD SHX Text

SL

SL

CO

CO

CO

CO

CO

CO

CO

CO

CO

50'-0"

5'-

0"

'-0

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

NOT TO SCALE

KEY

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

EROSION & SEDIMENT

CONTROL PLAN

CE-102

KEYNOTES

SEDIMENT FILTER LOG01

02 INLET PROTECTION

SEDIMENT FILTER LOG

1 EROSION & SEDIMENT CONTROL PLAN - MAINT. AREA

SCALE: 1" = 20'-0"

2 EROSION & SEDIMENT CONTROL PLAN - DETENTION POND

SCALE: 1" = 20'-0"

CE-201

3 EROSION & SEDIMENT CONTROL PLAN - MAINTENANCE ACCESS ROAD

SCALE: 1" = 20'-0"

5 EROSION & SEDIMENT CONTROL PLAN - SPOILS AREA

SCALE: 1" = 40'-0"

4 EROSION & SEDIMENT CONTROL PLAN - CAMP NELSON CEMETERY ROAD

SCALE: 1" = 20'-0"

03 HAY BALE SEDIMENT CHECK DAM

CE-201

CE-201

CE-201

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

HISTORIC MAINT. BUILDING

AutoCAD SHX Text

EQUIPMENT STORAGE BUILDING

AutoCAD SHX Text

HISTORIC BRICK STABLE

AutoCAD SHX Text

MAINTENANCE STORAGE BUILDING

AutoCAD SHX Text

REST & WASH HOUSE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text

SPKD

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text STK5 spkd (L-GPS) K:240524 Dist

AutoCAD SHX Text

AutoCAD SHX Text 912.909

AutoCAD SHX Text

EP10

AutoCAD SHX Text

AutoCAD SHX Text 913.262

AutoCAD SHX Text D12

AutoCAD SHX Text

AutoCAD SHX Text 912.559

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text 908.961

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text 913.440

AutoCAD SHX Text

A20 PC

AutoCAD SHX Text

AutoCAD SHX Text 907.313

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text 912.945

AutoCAD SHX Text

EP20

AutoCAD SHX Text

AutoCAD SHX Text 913.226

AutoCAD SHX Text A20

AutoCAD SHX Text

AutoCAD SHX Text 912.909

AutoCAD SHX Text

A20 PT D21

AutoCAD SHX Text

AutoCAD SHX Text 912.617

AutoCAD SHX Text

EP20 PT

AutoCAD SHX Text

AutoCAD SHX Text 912.297

AutoCAD SHX Text

D21 FA

AutoCAD SHX Text

AutoCAD SHX Text 911.672

AutoCAD SHX Text

EP20

AutoCAD SHX Text

AutoCAD SHX Text 912.227

AutoCAD SHX Text D22

AutoCAD SHX Text

AutoCAD SHX Text 911.497

AutoCAD SHX Text

EP20

AutoCAD SHX Text

AutoCAD SHX Text 911.709

AutoCAD SHX Text

EP20 PC

AutoCAD SHX Text

AutoCAD SHX Text 912.028

AutoCAD SHX Text

D22 A21 PC

AutoCAD SHX Text

AutoCAD SHX Text 907.416

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text 907.364

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text 914.196

AutoCAD SHX Text

ICV

AutoCAD SHX Text

AutoCAD SHX Text 914.538

AutoCAD SHX Text

HEADSTONE SECTION MARKER

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text STK5 spkd (L-GPS) K:240524 Dist

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text STK5 spkd (L-GPS) K:240524 Dist

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text

CK 5

AutoCAD SHX Text

AutoCAD SHX Text 912.268

AutoCAD SHX Text STK5 spkd (L-GPS) K:240524 Dist

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 8"

AutoCAD SHX Text Covered Car Port

AutoCAD SHX Text Concrete

AutoCAD SHX Text Concrete

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

INLET PROTECTION - AT GRADE

NOT TO SCALE

CROSS SECTION

DRAINAGE STRUCTURE

WALL

PLAN

SEDIMENT FILTER LOGNOMINAL 2X2

WOOD POST

" M

AX

12" MIN.

3" T

O

12" MIN.

GRASS

PAVEMENT

SEDIMENT FILTER LOG

BACK OF CURB

GUTTERLINE

PLAN VIEW

INLET PROTECTION - IN PAVEMENT

NOT TO SCALE

NOMINAL 2X2 WOOD POST

SEDIMENT FILTER LOG

NOMINAL 2X2 WOOD POST

40 LB SAND BAG (TYP.)

NOTES:

1. SECURE SEDIMENT FILTER LOGS TO THE SOIL SURFACE WITH WOODEN POSTS SPACED A MAXIMUM OF 2'

APART. WHEN USED ON A PAVED SURFACE, THE LOG ENDS SHALL BE FASTENED WITH PLASTIC TIES AND

SHALL BE SANDBAGGED OR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

2. INSPECT AFTER EVERY RUNOFF EVENT AND REPAIR AS NECESSARY. SEDIMENT SHALL BE REMOVED WHEN IT REACHES ONE -HALF THE MEASURE HEIGHT (STORAGE CAPACITY). SEDIMENT SHALL BE DISPOSED OF AS

UNSUITABLE MATERIALS.

3. CURLEX SEDIMENT LOG BY AMERICAN EXCELSIOR COMPANY, OR EQUAL AS APP'D BY COR.

PLAN

SEDIMENT FILTER LOGNOMINAL 2X2 WOOD POST

" M

AX

3" T

O

SEDIMENT FILTER LOG

NOT TO SCALE

CROSS SECTION

NOTES:

1. SECURE SEDIMENT FILTER LOGS TO THE SOIL SURFACE WITH WOODEN POSTS SPACED A MAXIMUM OF 2'

APART. WHEN USED ON A PAVED SURFACE, THE LOG ENDS SHALL BE FASTENED TOGETHER WITH PLASTIC TIES AND SHALL BE SANDBAGGED OR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.

2. INSPECT AFTER EVERY RUNOFF EVENT AND REPAIR AS NECESSARY. SEDIMENT SHALL BE REMOVED WHEN IT REACHES ONE -HALF THE MEASURE HEIGHT (STORAGE CAPACITY). SEDIMENT SHALL BE DISPOSED OF AS

UNSUITABLE MATERIALS.

3. CURLEX SEDIMENT LOG BY AMERICAN EXCELSIOR COMPANY, OR EQUAL AS APP'D BY COR.

POINT "B" POINT "A"

POINT "A"

EXISTING

GRADE

HAY BALE (TYP.) A

A

TEMPORARY SEDIMENT CHECK DAM

NOT TO SCALE

ELEVATION

HAY BALE

BINDING WIRE OR TWINE

COMPACTED SOIL TO

PREVENT PIPING

SEDIMENT LADEN

RUNOFF

FILTERED

RUNOFF

STAKES

NOTE:

TEMPORARY SEDIMENT BARRIER CONSISTING OF A ROW OF

ENTRENCHED AND ANCHORED BALES OF STRAW OR HAY, TO REDUCE

THE VELOCITY IN DITCHES. BALES SHALL BE IN ACCORDANCE WITH

PROJECT SPECIFICATIONS FOR TEMPORARY EROSION CONTROL.

SECTION A-A

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

Project No.

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

EROSION & SEDIMENT

CONTROL DETAILS

CE-201

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

Surveyor's Notes

SUE Notes

F

O L

CO

CO

CO

CO

Ex. Curb

Ex. Curb

Ex. 8" Headwall

Ex.

Conc.

PadConc. Pad

Ex. Asphalt Drive

Ex. Gravel Drive

Ex. Gravel Drive

Asphalt Drive

E x.

E d g e o f

A sp h a lt

E x.

E d g e o f C o n c

E x.

E d g e o f A sp h a lt

E x.

E d g e o f

C o n c

Ex. Edge of Asphalt Ex. Edge of Conc.

Ex.

ConcreteDrainageStructure

Ex.

Conc.

Pad

Ex. 8' Chainlink Fence

Ex. 8' ChainlinkFence

E x.

A sp h a lt

D rive

Conc.

Pad

8" Wall8" Wall

Asphalt Drive

Conc. Pad

Edge of Pvm t.

Edge of Conc.

Ex.

As pha lt D rive Ex.

Ed ge of Gra vel

Gr av el

Gravel Gr av el

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. 4"x4" WoodPost (Typ.)

Ex. Conc.Pad/FlagPole

Ex. 6' Chain Link

Ex. 6' Chain Link

CommittalShelter

D rive "B"

Entrance Drive

Drive "A"

CL

941.88

940.32

940.16

LEGEND

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

NOT TO SCALE

KEY

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

SITE DEMOLITION PLAN

CD-101

KEYNOTES

DEMOLISH EX. DRAIN INLETS. DRAIN PIPES TO REMAIN.01

CD-102

CD-102

CD-102

0 30 60 120 180

CD-102

FULL DEPTH PAVEMENT REMOVAL,

SEE CP-101 THRU CP-104

COLD PLANE (MILL) ASPHALT REMOVAL

(2" DEPTH), SEE CP-101 THRU CP-104

REMOVE ALL CURB IN PAVING LIMITS02

AutoCAD SHX Text

AutoCAD SHX Text 942.34

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 941.97

AutoCAD SHX Text

AutoCAD SHX Text 942.12

AutoCAD SHX Text 1.) Paper copies of this survey are not valid without the original signature and raised seal of a Paper copies of this survey are not valid without the original signature and raised seal of a Florida Licensed Surveyor and Mapper. Digital copies are not valid without the digital signature of a Florida Licensed Surveyor and Mapper. 2.) The horizontal datum utilized for this project is NAD 1983 Kentucky North Zone, 2011 The horizontal datum utilized for this project is NAD 1983 Kentucky North Zone, 2011 Adjustment, U.S. Survey Feet. Said datum was established by utilizing the Florida Permanent Reference Network (FPRN). 3.) The vertical datum utilized for this project is NAVD 1988, U.S. Survey Feet. Elevations were The vertical datum utilized for this project is NAVD 1988, U.S. Survey Feet. Elevations were established utilizing Opus 4.) As stipulated by state law, it is the contractor's responsibility to contact Sunshine State One As stipulated by state law, it is the contractor's responsibility to contact Sunshine State One Call of Florida at 1-800-432-4770 prior to conducting excavation. 5.) Markings for subsurface utilities have varying degrees of accuracies based on many different Markings for subsurface utilities have varying degrees of accuracies based on many different variables, such as but not limited to, high water table, soil conditions, and utility size and material. Always hand dig within 2-3 feet of any utilities or markings. 6.) All reasonable and commonly accepted techniques were applied to locating subsurface utilities All reasonable and commonly accepted techniques were applied to locating subsurface utilities as stipulated in the scope of work for this project, however, there may be other subsurface utilities and/or aboveground features not depicted hereon within the project limits. 7.) Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX Subsurface utilities depicted hereon were obtained using a Sensors and Software 250MHz LMX GPR and a Vivax Metrotech vLocPro utility locator and classified by observing above ground indicators in the field. 8.) No underground foundations or footers were excavated or located for this survey. No underground foundations or footers were excavated or located for this survey. 9.) THIS IS NOT A BOUNDARY SURVEY.THIS IS NOT A BOUNDARY SURVEY.

AutoCAD SHX Text 1.) Test Holes are recommended to verify designation. Test Holes are recommended to verify designation. 2.) Due to soil conditions GPR could not see deeper than 3.00 feet. Due to soil conditions GPR could not see deeper than 3.00± feet.3.) All concrete was reinforced. 4.) Per Mike with Camp Nelson, the cleanouts shown hereon are for storm structures. Per Mike with Camp Nelson, the cleanouts shown hereon are for storm structures. 5.) Site is on a septic system. Site is on a septic system. "A" Valve found with no tracer wire, could not induce or see with GPR. Valve found with no tracer wire, could not induce or see with GPR. *Note* The crew spoke with a maintenance team member on site who informed them that there were no water calves to the water main on the property. there was no tracer wire and no valves were found going to any of the water spouts. only one water valve on could be found on site.

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 8"

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text D

AutoCAD SHX Text Concrete

AutoCAD SHX Text 942.34

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text 941.97

AutoCAD SHX Text 942.12

AutoCAD SHX Text D

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text G

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text K

AutoCAD SHX Text H

AutoCAD SHX Text I

AutoCAD SHX Text J

AutoCAD SHX Text O

AutoCAD SHX Text W

AutoCAD SHX Text N

AutoCAD SHX Text

MC

AutoCAD SHX Text F

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text

WV

AutoCAD SHX Text B-1

AutoCAD SHX Text B-7

AutoCAD SHX Text B-2

AutoCAD SHX Text B-3

AutoCAD SHX Text B-8

AutoCAD SHX Text B-6

AutoCAD SHX Text B-5

AutoCAD SHX Text B-4

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 18"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 10"

AutoCAD SHX Text

AutoCAD SHX Text 942.12

AutoCAD SHX Text

AutoCAD SHX Text 941.97

AutoCAD SHX Text

AutoCAD SHX Text 938.05

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text Hog Wire Fence

AutoCAD SHX Text

AutoCAD SHX Text 934.47

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 935.96

AutoCAD SHX Text

GATE ON FENCE

AutoCAD SHX Text

AutoCAD SHX Text 942.34

AutoCAD SHX Text U

AutoCAD SHX Text N

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text V

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text S

AutoCAD SHX Text A

AutoCAD SHX Text F

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text S

AutoCAD SHX Text

PRIME CONSULTANT

13'-9"

12'-5"

13'-9"

42'-2"

42'-2"

12'-5"

13'-9"

15'-1 1" 16'-10"

N C A

ATIONAL

EMETERY

DMINISTRATION

Revisions Date

Drawing Title

Approved:

Approved:

Project Title

Building Number Checked Drawn

Location

Date

DRAWING NO.

Dwg. Of

1 2 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A B

C D

E F

A B

C D

E F

© COPYRIGHT 2022, Walker Federal Services, LLC

Walker Federal Services, LLC 7820B-162 Wormans Mill Road Frederick, Maryland 21701

WFS

Correct FCA Deficiencies

CAMP NELSON NATIONAL CEMETERY

833CM3030

ACM LMR

JANUARY 7, 2026

Bid Set

NOT TO SCALE

KEY

128 NORTHPARK BLVD.,

COVINGTON, LA 70433

ALAL

Engineering

PRINCIPPRINCIP

SITE DEMOLITION PLAN

CD-102

1. ALL WORK ON SEPTIC SYSTEM SHALL BE A PERFORMED

CERTIFIED ONSITE SEWAGE SYSTEM INSTALLER, LICENSED IN

THE STATE OF KENTUCKY.

2. BOUNDS OF EX. LEACH FIELD AND LOCATION OF LATERALS ARE

APPROXIMATE AND SHALL BE FIELD VERIFIED BY THE

CONTRACTOR PRIOR TO DEMO. PRESERVE EXISTING ADJACENT

LATERAL TILES.

3. LOCATION OF SEPTIC TANK & DISTRIBUTION BOX ARE

APPROXIMATE AND SHALL BE FIELD VERIFIED BY CONTRACTOR

PRIOR TO PIPE REMOVAL. SANITARY SERVICE SHALL BE

PROVIDED AT ALL TIMES. POSITIVELY LOCATE, IDENTIFY, AND

PROTECT EXISTING CROSSING UTILITES TO REMAIN.

4. REMOVE, STORE, AND PROTECT EXISTING DRAIN GRATE AND

COLLAR IN THEIR ENTIRETY. RESTORE DRAIN GRATE AND

PREPARE FOR REINSTALLATION IN NEW CONCRETE PAVEMENT.

SEE AE-002 FOR CAST IRON CONSERVATION NOTES.

5. NEAT VERTICAL SAWCUT IS REQUIRED BETWEEN PAVEMENT TO

BE REMOVED AND PAVEMENT TO REMAIN.

6. EXERCISE EXTREME CAUTION TO AVOID DAMAGE TO SEPTIC

LATERAL TILES. DO NOT OPERATE EQUIPMENT OVER LEACH

FIELD.

7.

KEYNOTES

SELECTIVELY DEMOLISH EX. PAVEMENT (SEE NOTE 5)01

02 BOLLARD TO BE REMOVED

03 FUEL TANK TO BE REMOVED, LEGALLY DISPOSE OF WASTE

FUEL AND TANK

PAVEMENT/AGGREGATE SURFACE REMOVAL

04 SELECTIVELY REMOVE EXISTING SEPTIC LEACH FIELD TILES,

PIPING, AND SOIL FOR POINT REPAIR (SEE NOTE 2)

05 SEPTIC TANK TO REMAIN, SANITARY PIPING TO BE REMOVED,

APPROX. PIPE DEPTH 934.41 (SEE NOTE 3)

1 DEMOLITION PLAN - MAINTENANCE AREA

SCALE: 1" = 20'-0"

2 DEMOLITION PLAN - CEMETERY ROAD

SCALE: 1" = 10'-0"

3 DEMOLITION PLAN - CEMETERY ROAD

SCALE: 1" = 10'-0"

09 DEMOLISH EX. DRAIN INLET BASIN.

SALVAGE HISTORIC GRATE (SEE NOTE 4)

06 SEPTIC DISTRIBUTION BOX TO REMAIN (SEE NOTE 3)

4 DEMOLITION PLAN - SPOILS AREA

SCALE: 1" = 40'-0"

11 EXISTING AGGREGATE DRAIN BED (TO REMAIN)

NOTES

10 EMPLOY LICENSED ARBORIST, REMOVE TREES AND GRIND

STUMPS (SEE NOTE 6)

10 12 DEMOLISH EXISTING SPOILS STORAGE SHELTER

APPROX. LIMITS OF LEACH FIELD REMOVAL

(SEE NOTE 1)

EXISTING SANITARY SEWER (TO BE REMOVED)

13 REMOVE, STORE, & PROTECT PROPANE STORAGE TANK

(SEE NOTE 7)

14 REMOVE, STORE, & PROTECT AC CONDENSER (SEE NOTE 7)

07 REMOVE EX. AGGREGATE SURFACE

08 DEMOLISH EX. LEAN-TO SHELTER

LEGEND

AutoCAD SHX Text 937.79

AutoCAD SHX Text 937.38

AutoCAD SHX Text 938.21

AutoCAD SHX Text 942.62

AutoCAD SHX Text 943.88

AutoCAD SHX Text 941.21

AutoCAD SHX Text 935.86

AutoCAD SHX Text 937.18

AutoCAD SHX Text 937.10

AutoCAD SHX…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .