A-Mechanical-Part 1.pdf
PDF 8 MB Posted
- Solicitation number
- QSE--36C10F24R50018
About this file
This document is a set of construction plans and drawings related to a federal contract opportunity for the Balance of Work at the VA Medical Center (VAMC) in Manhattan, New York. The plans and drawings provide detailed information on the mechanical, electrical, and piping systems that are to be demolished and installed as part of the construction work.
The key details include:
- The solicitation number is QSE--36C10F24R50018, with the opportunity titled "36C10F24R50018 Balance of Work VAMC Manhattan, NY -- Y1DA".
- The work involves constructing the Manhattan Hurricane Sandy Recovery Program Balance of Work at the VAMC Manhattan Campus of the VA NY Healthcare System.
- The drawings provide comprehensive details on the demolition and installation of mechanical, electrical, and piping systems, including HVAC equipment, ductwork, steam/condensate piping, chilled water piping, and more.
- The drawings cover the ground floor, third floor, and fourth floor/roof areas of the building.
View the file
Other files
Show 40 more
Latest 50 of 281 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECHANICAL SYMBOLS, ABBREVIATIONS,
AND GENERAL NOTES
TM/BH IR
A-M001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
Key Plan
Balance of Work
9/12/2022
AutoCAD SHX Text
DUCT MOUNTED COIL
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text
RETURN
AutoCAD SHX Text 45%%d
AutoCAD SHX Text
MANUAL SPLITTER DAMPER
AutoCAD SHX Text 45%%d
AutoCAD SHX Text N
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
COMBINATION FIRE/SMOKE DAMPER
AutoCAD SHX Text 1/2
AutoCAD SHX Text
AutoCAD SHX Text
STAINLESS STEEL DUCT
AutoCAD SHX Text
FS DPR
AutoCAD SHX Text
AUTOMATIC CONTROL DAMPER MODULATING
AutoCAD SHX Text
AUTOMATIC CONTROL DAMPER TWO POSITION
AutoCAD SHX Text
%%UPIPING SYMBOLS
AutoCAD SHX Text
HIGH PRESSURE STEAM
AutoCAD SHX Text
HIGH PRESSURE STEAM
AutoCAD SHX Text
HOT WATER HEATING SUPPLY
AutoCAD SHX Text
CONDENSATE PUMP DISCHARGE
AutoCAD SHX Text
LOW PRESSURE STEAM
AutoCAD SHX Text
LOW PRESSURE STEAM
AutoCAD SHX Text
MEDIUM PRESSURE STEAM
AutoCAD SHX Text
MEDIUM PRESSURE STEAM
AutoCAD SHX Text
VENT LINE
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
DRAIN LINE
AutoCAD SHX Text
MAKE-UP WATER
AutoCAD SHX Text
HOT WATER HEATING RETURN
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HPR
AutoCAD SHX Text
MPS
AutoCAD SHX Text
MPR
AutoCAD SHX Text
LPS
AutoCAD SHX Text
LPR
AutoCAD SHX Text
PC
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HWR
AutoCAD SHX Text V
AutoCAD SHX Text
CHR
AutoCAD SHX Text
CHS
AutoCAD SHX Text
MW
AutoCAD SHX Text D
AutoCAD SHX Text X
AutoCAD SHX Text
EXISTING PIPE TO BE REMOVED
AutoCAD SHX Text
ANCHOR
AutoCAD SHX Text
REDUCER OR INCREASER
AutoCAD SHX Text
DIRECTION OF FLOW
AutoCAD SHX Text
SIDE CONNECTION
AutoCAD SHX Text
ECCENTRIC REDUCER
AutoCAD SHX Text BOTTOM CONNECTION, 45%%d OR 90%%d
AutoCAD SHX Text TOP CONNECTION, 45%%d OR 90%%d
AutoCAD SHX Text
DIRECTION OF PIPE PITCH (DOWN)
AutoCAD SHX Text
UNION
AutoCAD SHX Text
RISE OR DROP IN PIPE
AutoCAD SHX Text
CAPPED OUTLET
AutoCAD SHX Text
PRESSURE GAGE
AutoCAD SHX Text
THERMOMETER
AutoCAD SHX Text
FLOW ELEMENT
AutoCAD SHX Text
FE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
PIPE UP
AutoCAD SHX Text
PIPE DOWN
AutoCAD SHX Text
REFRIGERANT SIGHT GLASS
AutoCAD SHX Text
TEST PLUG (PRESSURE/TEMPERATURE)
AutoCAD SHX Text
AUTOMATIC AIR VENT
AutoCAD SHX Text
AV
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
MV
AutoCAD SHX Text
QUICK-COUPLE HOSE CONNECTOR
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text CENT CENTRIFICAL CFH CUBIC FEET PER HOUR CUBIC FEET PER HOUR CFM CUBIC FEET PER MINUTE CUBIC FEET PER MINUTE CFT CUBIC FEET CUBIC FEET CG CEILING GRILLE CEILING GRILLE CH CHILLER CHILLER CHP CHILLED WATER PUMP CHILLED WATER PUMP CHW CHILLER WATER CHILLER WATER CHR CHILLED WATER RETURN CHS CHILLED WATER SUPPLY CM CARBON MONOXIDE CARBON MONOXIDE CM CUBIC METER CUBIC METER CM/S CUBIC METER PER SECOND CO CLEAN OUT CLEAN OUT CO2 CARBON DIOXODE CARBON DIOXODE CP CONDENSATE PUMP CONDENSATE PUMP CR CEILING REGISTER CEILING REGISTER CV CONSTANT VOLUME CONSTANT VOLUME CW COLD WATER (POTABLE) COLD WATER (POTABLE)
AutoCAD SHX Text BD BUTTERFLY DAMPER BUTTERFLY DAMPER BDD BACKDRAFT DAMPER BACKDRAFT DAMPER BG BOTTOM GRILLE BOTTOM GRILLE BHP BRAKE HORSEPOWER BRAKE HORSEPOWER BR BOTTOM REGISTER BOTTOM REGISTER BTU BRITISH THERMAL UNIT BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR
AutoCAD SHX Text A/E ARCHITECT / ENGINEER ARCHITECT / ENGINEER AABC ASSOCIATED AIR BALANCE COUNCIL AAV AUTOMATIC AIR VENT AUTOMATIC AIR VENT ACU AIR CONDITIONING UNIT AIR CONDITIONING UNIT AD ACCESS DOOR ACCESS DOOR AF AFTER FILTER AFTER FILTER AFF ABOVE FINISHED FLOOR ABOVE FINISHED FLOOR AFMD AIR FLOW MEASURING DEVICE AIR FLOW MEASURING DEVICE AHU AIR-HANDLING UNIT AIR-HANDLING UNIT AMP AMPERAGE AMPERAGE AP ACCESS PANEL ACCESS PANEL APD AIR PRESSURE DROP AIR PRESSURE DROP ARI AIR CONDITIONING AND AIR CONDITIONING AND REFRIGERATION INSTITUTE AS AIR SEPARATOR AIR SEPARATOR ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS
AutoCAD SHX Text C CENTIGRADE (CELCIUS) CENTIGRADE (CELCIUS) CC COOLING COIL COOLING COIL CCD COOLING COIL CONDENSATE DRAIN COOLING COIL CONDENSATE DRAIN CD CEILING DIFFUSER CEILING DIFFUSER CO CLEAN OUT CLEAN OUT
AutoCAD SHX Text EA EXHAUST AIR EXHAUST AIR EAT ENTERING AIR TEMPERATURE ENTERING AIR TEMPERATURE ECC ENGINEERING CONTROL CENTER ENGINEERING CONTROL CENTER EER ENERGY EFFICIENCY RATIO ENERGY EFFICIENCY RATIO EF EXHAUST FAN EXHAUST FAN EG EXHAUST GRILLE EXHAUST GRILLE ENT ENTERING ER EXHAUST REGISTER EXHAUST REGISTER ESP EXTERNAL STATIC PRESSURE EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE ENTERING WATER TEMPERATURE EX. EXISTING EXISTING
AutoCAD SHX Text F FAHRENHEIT FAHRENHEIT F&T FLOAT AND THERMOSTATIC FLOAT AND THERMOSTATIC F/SDPR COMBINATION FIRE SMOKE DAMPER FA FREE AREA FREE AREA FC FLEXIBLE CONNECTION FLEXIBLE CONNECTION FCU FAN COIL UNIT (4 PIPE) FAN COIL UNIT (4 PIPE) FCUC FAN COIL UNIT COOLING ONLY FAN COIL UNIT COOLING ONLY FCUH FAN COIL UNIT HEATING ONLY FCW FORWARD CURVED WHEEL (FAN) FORWARD CURVED WHEEL (FAN) FD FLOOR DRAIN FLOOR DRAIN FD FIRE DAMPER FIRE DAMPER FF FINAL FILTER FINAL FILTER FM FLOW METER FLOW METER FPM FEET PER MINUTE FEET PER MINUTE FPS FEET PER SECOND FEET PER SECOND FPTU FAN POWERED TERMINAL UNIT FAN POWERED TERMINAL UNIT FR FLOOR REGISTER FLOOR REGISTER FS FLOW SWITCH FLOW SWITCH FT FEET FEET FT-LB FOOT-POUND FV FACE VELOCITY
AutoCAD SHX Text GA GAUGE GAUGE GAL GALLONS GH GRAVITY HOOD GRAVITY HOOD GPD GALLONS PER DAY GALLONS PER DAY GPH GALLONS PER HOUR GALLONS PER HOUR GPM GALLONS PER MINUTE GALLONS PER MINUTE GS GALVANIZED STEEL GALVANIZED STEEL
AutoCAD SHX Text OA OUTSIDE AIR OUTSIDE AIR OAG OUTSIDE AIR GRILLE OUTSIDE AIR GRILLE OAI OUTSIDE AIR INTAKE OUTSIDE AIR INTAKE OD OUTSIDE DIAMETER OUTSIDE DIAMETER OR OPERATING ROOM OPERATING ROOM
AutoCAD SHX Text NA NOT APPLICABLE NOT APPLICABLE NC NOISE CRITERIA NOISE CRITERIA NC NORMALLY CLOSED NORMALLY CLOSED NEBB NATIONAL ENVIRONMENTAL BALANCING BUREAU NEMI NATIONAL ENERGY MANAGEMENT INSTITUTE NO NORMALLY OPEN NORMALLY OPEN NOM NOMINAL NOMINAL NTS NOT TO SCALE NOT TO SCALE
AutoCAD SHX Text M METER, SI UNIT METER, SI UNIT M/s METERS PER SECOND METERS PER SECOND (OR METERS/SECOND) MA MIXED AIR MIXED AIR MAT MIXED AIR TEMPERATURE MIXED AIR TEMPERATURE MAU MAKE-UP AIR UNIT MAKE-UP AIR UNIT MAV MANUAL AIR VENT MANUAL AIR VENT MAX MAXIMUM MAXIMUM MB MIXING BOX MIXING BOX MBH 1000 BTUH 1000 BTUH MCA MINIMUM BRANCH CIRCUIT AMPACITY MINIMUM BRANCH CIRCUIT AMPACITY MER MECHANICAL EQUIPMENT ROOM MECHANICAL EQUIPMENT ROOM MERV MINIMUM EFFICIENCY REPORTING MINIMUM EFFICIENCY REPORTING VALUE MHP MOTOR HORSEPOWER MOTOR HORSEPOWER MIN MINIMUM MINIMUM MM MILLIMETER MILLIMETER MRI MAGNETIC RESONANCE IMAGING MAGNETIC RESONANCE IMAGING MTD MEAN TEMPERATURE DIFFERENCE MEAN TEMPERATURE DIFFERENCE MVD MANUAL VOLUME DAMPER MANUAL VOLUME DAMPER MZ MULTI-ZONE MULTI-ZONE
AutoCAD SHX Text L LITER LITER L/h LITERS PER HOUR (OR LITERS/HOUR) LITERS PER HOUR (OR LITERS/HOUR) L/m LITERS PER MINUTE (OR LITERS/MINUTE) LITERS PER MINUTE (OR LITERS/MINUTE) L/s LITERS PER SECOND (OR LITERS/SECOND) LITERS PER SECOND (OR LITERS/SECOND) LAT LEAVING AIR TEMPERATURE LEAVING AIR TEMPERATURE LBS/HR POUNDS PER HOUR LF LINEAR FOOT (FEET) LINEAR FOOT (FEET) LH LATENT HEAT LATENT HEAT LSD LINEAR SLOT DIFFUSER LINEAR SLOT DIFFUSER LTCP LOCAL TEMPERATURE CONTROL PANEL LOCAL TEMPERATURE CONTROL PANEL LVG LEAVING LVR LOUVER LOUVER LWT LEAVING WATER TEMPERATURE LEAVING WATER TEMPERATURE
AutoCAD SHX Text kg KILOGRAM KILOGRAM kg/HR KILOGRAM PER HOUR kPa KILOPASCAL KILOPASCAL kW KILOWATT KILOWATT kWh KILOWATT HOUR KILOWATT HOUR
AutoCAD SHX Text I/O INPUT/OUTPUT INPUT/OUTPUT IAQ INDOOR AIR QUALITY INDOOR AIR QUALITY ICF IN-LINE CENTRIFUGAL FAN IN-LINE CENTRIFUGAL FAN ICU INTENSIVE CARE UNIT INTENSIVE CARE UNIT ID INSIDE DIAMETER INSIDE DIAMETER IN INCHES IN HG INCHES OF MERCURY IN WC INCH WATER COLUMN IN WG INCH WATER GAUGE IN-LB INCH-POUND
AutoCAD SHX Text R/E RETURN OR EXHAUST RETURN OR EXHAUST RA RETURN AIR RETURN AIR RAT RETURN AIR TEMPERATURE RETURN AIR TEMPERATURE RD R00F DRAIN R00F DRAIN REA RELIEF AIR RELIEF AIR RF RETURN FAN RETURN FAN RG RETURN GRILLE RETURN GRILLE RH RELATIVE HUMIDITY RELATIVE HUMIDITY RHC REHEAT COIL REHEAT COIL RPM REVOLUTIONS PER MINUTE REVOLUTIONS PER MINUTE RR RETURN REGISTER RETURN REGISTER RV RELIEF VALVE RELIEF VALVE
AutoCAD SHX Text
YR YEAR YEAR
AutoCAD SHX Text D DAMPER - AUTOMATIC DAMPER - AUTOMATIC D-1 OUTDOOR AIR DAMPER OUTDOOR AIR DAMPER D-2 RETURN AIR DAMPER RETURN AIR DAMPER D-3 RELIEF AIR DAMPER RELIEF AIR DAMPER DB DECIBELS DECIBELS Db DRY-BULB TEMPERATURE DRY-BULB TEMPERATURE DDC DIRECT DIGITAL CONTROLS DIRECT DIGITAL CONTROLS DEG DEGREE DEGREE DF DIFFUSER DIFFUSER DIA DIAMETER DIAMETER DP DEW POINT TEMPERATURE DEW POINT TEMPERATURE
AutoCAD SHX Text P PUMP PUMP PA PASCAL PASCAL PC PUMPED CONDENSATE PUMPED CONDENSATE PCF POUNDS PER CUBIC FOOT (FEET) POUNDS PER CUBIC FOOT (FEET) PD PRESSURE DROP PRESSURE DROP PEF PROPELLER (TYPE) EXHAUST FAN PROPELLER (TYPE) EXHAUST FAN PF PRE-FILTER PRE-FILTER PG PRESSURE GAGE PRESSURE GAGE PHC PREHEAT COIL PREHEAT COIL PPM PARTS PER MILLION PARTS PER MILLION PRS PRESSURE REGULATING (VALVE) STATION PRESSURE REGULATING (VALVE) STATION PRV PRESSURE REGULATING VALVE PRESSURE REGULATING VALVE PSI POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH PSIA POUNDS PER SQUARE INCH – ABSOLUTE POUNDS PER SQUARE INCH – ABSOLUTE ABSOLUTE PSIG POUNDS PER SQUARE INCH – GAGE POUNDS PER SQUARE INCH – GAGE GAGE PSS PRIMARY SECONDARY SYSTEM PRIMARY SECONDARY SYSTEM PSV PRESSURE SAFETY VALVE PRESSURE SAFETY VALVE PTAC PACKAGED TERMINAL AIR CONDITIONER PACKAGED TERMINAL AIR CONDITIONER
AutoCAD SHX Text UC UNDER CUT UNDER CUT UC UNIT COOLER UNIT COOLER UH UNIT HEATER UNIT HEATER UL UNDERWRITERS LABORATORY UNDERWRITERS LABORATORY
AutoCAD SHX Text
%%UDUCTWORK SYMBOLS
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
SUPPLY DUCT (UP & DOWN)
AutoCAD SHX Text
EXHAUST DUCT (UP & DOWN)
AutoCAD SHX Text
ROUND AND SQUARE 4-WAY CEILING DIFFUSERS
AutoCAD SHX Text
SUPPLY TOP REGISTER OR GRILLE (WALL TYPE)
AutoCAD SHX Text
EXHAUST OR RETURN CEILING REGISTER OR GRILLE
AutoCAD SHX Text
VANED ELBOW & AIR SPLIT TYPE DUCT TAKE-OFF
AutoCAD SHX Text
CONNECT NEW DUCT TO EXISTING DUCT
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
RETURN DUCT (UP & DOWN)
AutoCAD SHX Text
SQUARE 3-WAY CEILING DIFFUSERS
AutoCAD SHX Text
SQUARE 2-WAY CEILING DIFFUSERS
AutoCAD SHX Text
LINEAR SLOT DIFFUSER
AutoCAD SHX Text
SQUARE 1-WAY CEILING DIFFUSERS
AutoCAD SHX Text
LIMIT OF DEMOLITION
AutoCAD SHX Text D
AutoCAD SHX Text
INCLINED RISE, IN DIRECTION OF AIR FLOW
AutoCAD SHX Text
INCLINED DROP, IN DIRECTION OF AIR FLOW
AutoCAD SHX Text R
AutoCAD SHX Text
BACK DRAFT DAMPER
AutoCAD SHX Text
BDD
AutoCAD SHX Text
FC
AutoCAD SHX Text 10x8
AutoCAD SHX Text
VANED ELBOW (SHORT RADIUS)
AutoCAD SHX Text
STANDARD RADIUS ELBOW (LONG RADIUS)
AutoCAD SHX Text NEW DUCT (INSIDE DIMENSIONS: WIDTH x DEPTH)
AutoCAD SHX Text
EXISTING DUCT TO REMAIN
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
FD
AutoCAD SHX Text
VD
AutoCAD SHX Text
DUCT WITH SOUND LINING
AutoCAD SHX Text
FLEXIBLE DUCTWORK (INSULATED)
AutoCAD SHX Text
MANUAL VOLUME DAMPER
AutoCAD SHX Text
EXISTING DUCT TO BE REMOVED
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text H HUMIDIFER H&CW HOT & COLD WATER HB HOSE BIBB HOSE BIBB HC HEATING COIL HEATING COIL HD HEAD HEAD HOA HAND/OFF/AUTOMATIC HAND/OFF/AUTOMATIC HP HORSEPOWER HORSEPOWER HPDT HIGH PRESSURE DRIP TRAP HIGH PRESSURE DRIP TRAP HPR HIGH PRESSURE RETURN HIGH PRESSURE RETURN (STEAM CONDENSATE) HPS HIGH PRESSURE SUPPLY HIGH PRESSURE SUPPLY (STEAM) HRC HEAT RECOVERY COIL HEAT RECOVERY COIL HRD HEAT RECOVERY DEVICE HEAT RECOVERY DEVICE HRP HYDRONIC RADIANT (CEILING) HYDRONIC RADIANT (CEILING) PANEL HRW HEAT RECOVERY WHEEL HEAT RECOVERY WHEEL HSTAT HUMIDISTAT HTM HUMIDIFIER TERMINAL HUMIDIFIER TERMINAL HUM HUMIDIFIER UNIT MOUNTED HUMIDIFIER UNIT MOUNTED HVU HEATING AND VENTILATING UNIT HEATING AND VENTILATING UNIT HW HOT WATER HOT WATER HWC HOT WATER COIL HOT WATER COIL HWHC HOT WATER HEATING COIL HWP HEATING HOT WATER PUMP HEATING HOT WATER PUMP HWR HEATING HOT WATER RETURN HEATING HOT WATER RETURN HWS HEATING HOT WATER SUPPLY HEATING HOT WATER SUPPLY HWUH HOT WATER UNIT HEATER HX HEAT EXCHANGER HEAT EXCHANGER HZ HERTZ HERTZ
AutoCAD SHX Text SA SUPPLY AIR SUPPLY AIR SAD SOUND ATTENUATING DEVICE SOUND ATTENUATING DEVICE SAT SUPPLY AIR TEMPERATURE SUPPLY AIR TEMPERATURE SC SHADING COEFFICIENT SHADING COEFFICIENT SCFM STANDARD CUBIC FEET PER MINUTE SCI SPINAL CODE INJURY SCR SILICON CONTROLLED RECTIFIER SILICON CONTROLLED RECTIFIER SD SMOKE DETECTOR SMOKE DETECTOR SD SUPPLY AIR DIFFUSER SUPPLY AIR DIFFUSER SDPR SMOKE DAMPER SMOKE DAMPER SDR SMOKE DAMPER (RETURN) SDS SMOKE DAMPER (SUPPLY) SEN SENSIBLE HEAT SENSIBLE HEAT SF SUPPLY FAN SUPPLY FAN SG SUPPLY AIR GRILLE SUPPLY AIR GRILLE SH STEAM HUMIDIFIER STEAM HUMIDIFIER SHC STEAM HEATING COIL SI SQUARE INCHES SQUARE INCHES SP STATIC PRESSURE STATIC PRESSURE SP GR SPECIFIC GRAVITY SPD SUPPLY PROCESS AND DISTRIBUTION SPRV STEAM PRESSURE REDUCING VALVE SPS STATIC PRESSURE SENSOR STATIC PRESSURE SENSOR SQ FT SQUARE FOOT (FEET) SR SUPPLY AIR REGISTER SUPPLY AIR REGISTER SS STAINLESS STEEL STAINLESS STEEL SSHX STEAM TO STEAM HEAT EXCHANGER SSR SOLID SEPARATOR SOLID SEPARATOR ST STEAM TRAP SUH STEAM UNIT HEATER SV STEAM PRESSURE REDUCING VALVE STEAM PRESSURE REDUCING VALVE
AutoCAD SHX Text T & PCV TEMPERATURE AND PRESSURE CONTROL VALVE TAB TESTING, ADJUSTING, BALANCE TESTING, ADJUSTING, BALANCE TD TEMPERATURE DIFFERENCE TEMPERATURE DIFFERENCE TDH TOTAL DYNAMIC HEAD TOTAL DYNAMIC HEAD TDS TOTAL DISSOLVED SOLIDS TOTAL DISSOLVED SOLIDS TG TRANSFER GRILLE TRANSFER GRILLE TP TRAP TRAP TR TOP REGISTER TOP REGISTER TSP TOTAL STATIC PRESSURE TOTAL STATIC PRESSURE TSTAT THERMOSTAT THERMOSTAT TU TERMINAL UNIT TERMINAL UNIT TWU THRU-WALL UNIT THRU-WALL UNIT
AutoCAD SHX Text V VALVE VALVE VAF VANE-AXIAL FAN VANE-AXIAL FAN VAV VARIABLE AIR VOLUME VARIABLE AIR VOLUME VD VOLUME DAMPER (MANUAL OPPOSED BLADE) VOLUME DAMPER (MANUAL OPPOSED BLADE) VFD VARIABLE FREQUENCY DRIVE VARIABLE FREQUENCY DRIVE VHA VETERANS HEALTH ADMINISTRATION VI VIBRATION ISOLATOR VIBRATION ISOLATOR VIV VARIABLE INLET VANES VARIABLE INLET VANES VP VACUUM PUMP VACUUM PUMP VPS VARIABLE PRIMARY SYSTEM VR VACUUM (STEAM CONDENSATE) RETURN VACUUM (STEAM CONDENSATE) RETURN VSD VARIABLE SPEED DRIVE VUH VERTICAL UNIT HEATERVERTICAL UNIT HEATER
AutoCAD SHX Text W WATTS WAG WASTE ANETHESIA GAS WASTE ANETHESIA GAS Wb WET-BULB (TEMPERATURE) WET-BULB (TEMPERATURE) WC WATER COOLED WCCH WATER COOLED CHILLER WCCU WATER COOLED CONDENSING UNIT WCHP WATER COOLED HEAT PUMPS WCPU WATER COOLED PACKAGED UNIT WEF WALL EXHAUST FAN WALL EXHAUST FAN WF WATER FILTER WATER FILTER WFCV WATER FLOW CONTROL VALVE WFM WATER FLOWMETER WFMD WATER FLOW MEASURING DEVICE WG WATER GAGE WATER GAGE WPD WATER SIDE PRESSURE DROP WATER SIDE PRESSURE DROP
AutoCAD SHX Text P
AutoCAD SHX Text M
AutoCAD SHX Text
FD
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
ANGLE VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
PRESSURE REGULATING VALVE
AutoCAD SHX Text
SAFETY RELIEF VALVE
AutoCAD SHX Text
BASKET STRAINER
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
PRESSURE GAUGE WITH COCK
AutoCAD SHX Text
CAP OR PLUG
AutoCAD SHX Text
AIR VENT WITH VALVE
AutoCAD SHX Text
METER
AutoCAD SHX Text
2-WAY MODULATING CONTROL VALVE
AutoCAD SHX Text ALL FLOOR MOUNTED MECHANICAL EQUIPMENT WITHOUT VIBRATION ISOLATION SHALL BE BOLTED TO THE FLOOR OR A CONCRETE PAD. ALL SUSPENDED MECHANICAL EQUIPMENT WEIGHING 31 POUNDS OR MORE SHALL BE INSTALLED TO RESIST FORCES OF 0.5 TIMES THE EQUIPMENT WEIGHT IN ANY DIRECTION AND 1.5 TIMES THE EQUIPMENT WEIGHT IN THE DOWNWARD DIRECTION. DO NOT ANCHOR ATFP BRACING TO POST-TENSIONED BEAMS OR GIRDERS.
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text
ANTI-TERRORISM/FORCE PROTECTION (ATFP) NOTES:
AutoCAD SHX Text
DOMESTIC HOT WATER
AutoCAD SHX Text
DOMESTIC COLD WATER
AutoCAD SHX Text
STORM WATER
AutoCAD SHX Text
SD
AutoCAD SHX Text
OXYGEN
AutoCAD SHX Text O
AutoCAD SHX Text
MEDICAL AIR
AutoCAD SHX Text
MA
AutoCAD SHX Text
SANITARY
AutoCAD SHX Text
SAN
AutoCAD SHX Text
MEDICAL VACUUM
AutoCAD SHX Text
MV
AutoCAD SHX Text
RL
AutoCAD SHX Text
AutoCAD SHX Text
ROOF LEADER
AutoCAD SHX Text
RISER NUMBER
AutoCAD SHX Text
AutoCAD SHX Text
MSD-101
AutoCAD SHX Text
DWG. SHEET WHERE DRAWN
AutoCAD SHX Text
MD-102
AutoCAD SHX Text
REFERNCE DWG. SHEET
AutoCAD SHX Text
PARTIAL PLAN NO.
AutoCAD SHX Text
REFRIGERANT LIQUID
AutoCAD SHX Text
RL
AutoCAD SHX Text
REFRIGERANT SUCTION
AutoCAD SHX Text
RS
AutoCAD SHX Text
CONDENSER WATER RETURN (DRYCOOLER)
AutoCAD SHX Text
CWR
AutoCAD SHX Text
CONDENSER WATER SUPPLY (DRYCOOLER)
AutoCAD SHX Text
CWS
AutoCAD SHX Text
THREE-WAY VALVE
AutoCAD SHX Text
FUEL OIL SUPPLY
AutoCAD SHX Text
FUEL OIL RETURN
AutoCAD SHX Text
FOR
AutoCAD SHX Text
FOS
AutoCAD SHX Text
FUEL OIL POLISHER SUPPLY
AutoCAD SHX Text
FUEL OIL POLISHER RETURN
AutoCAD SHX Text
FOPR
AutoCAD SHX Text
FOPS
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
DUCT SMOKE DETECTOR
AutoCAD SHX Text S
AutoCAD SHX Text
1. ALL MECHANICAL WORK SHALL CLOSELY FOLLOW THE VA DESIGN MANUALS, PHYSICAL SECURITY ALL MECHANICAL WORK SHALL CLOSELY FOLLOW THE VA DESIGN MANUALS, PHYSICAL SECURITY DESIGN MANUAL FOR VA FACILITIES, AND ALL CURRENT APPLICABLE CODES. 2. SUPPORT ALL MECHANICAL DUCTWORK, PIPING, AND MECHANICAL EQUIPMENT WITH SERVICE POINT SUPPORT ALL MECHANICAL DUCTWORK, PIPING, AND MECHANICAL EQUIPMENT WITH SERVICE POINT LOADS IN EXCESS OF (100 POUNDS) FROM ANY ONE HANGER ATTACHMENT POINT BY STRUCTURAL SUB-ASSEMBLIES ATTACHED TO FLANGES OF EXISTING STEEL BEAMS OF BUILDING 1. DO NOT HANG THESE ITEMS FROM THE EXISTING SLAB. MECHANICAL EQUIPMENT WEIGHT NOT TO EXCEED 500 LBS. WHEN ATTACHED TO TWO EXISTING BEAMS, AND 800 LBS. WHEN ATTACHED TO THREE EXISTING BEAMS. 3. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A FURRED ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN A FURRED CHASE OR ABOVE THE HARD OR SUSPENDED CEILING. 4. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. DUCT SIZES ARE NET INSIDE DIMENSIONS. 5. ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS, DAMPERS, ACCESS PANELS IN HARD SUSPENDED CEILINGS ARE REQUIRED FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC. ACCESS PANEL SHALL BE FURNISHED AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATIONS. 6. TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL UNITS, TOTAL STATIC PRESSURE NOTED IN THE SCHEDULES INCLUDES DUCT SYSTEM, TERMINAL UNITS, FILTERS, COILS, ETC. 7. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES. DIFFUSER, REGISTER AND GRILLE SIZES SHOWN ON FLOOR PLANS ARE NECK SIZES. 8. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS OF CEILING DIFFUSERS, REGISTERS, AND GRILLES. 9. INSULATION AND VAPOR BARRIERS ON EXISTING DUCTS AND PIPING WHICH HAS BEEN REMOVED OR INSULATION AND VAPOR BARRIERS ON EXISTING DUCTS AND PIPING WHICH HAS BEEN REMOVED OR DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED IN ACCORDANCE WITH SPECIFICATIONS FOR NEW WORK. 10. EXISTING EQUIPMENT AND MATERIALS SHOWN TO BE REMOVED OR DEMOLISHED SHALL BE REMOVED EXISTING EQUIPMENT AND MATERIALS SHOWN TO BE REMOVED OR DEMOLISHED SHALL BE REMOVED FROM THE SITE BY THE CONTRACTOR AND SHALL BE DISPOSED OFF IN A MANNER THAT MEETS ALL LOCAL AND STATE CODES AND STANDARDS. 11. CAP OR PATCH AS NECESSARY ALL UNUSED DUCT OPENINGS OR CONNECTIONS RESULTING FROM CAP OR PATCH AS NECESSARY ALL UNUSED DUCT OPENINGS OR CONNECTIONS RESULTING FROM DEMOLITION AND RE-INSULATE AND REPAIR VAPOR BARRIERS AS REQUIRED. 12. REPAIR ALL UNUSED MECHANICAL OPENINGS AND PENETRATIONS IN EXISTING WALLS AND/OR REPAIR ALL UNUSED MECHANICAL OPENINGS AND PENETRATIONS IN EXISTING WALLS AND/OR FLOORS RESULTING FROM DEMOLITION WORK. PATCH AND REPAIR OPENINGS TO MATCH EXISTING WALL/FLOOR CONSTRUCTION AND RATING. 13. MECHANICAL EQUIPMENT AND/OR AIR DEVICES NOTED OR INDICATED FOR RELOCATION SHALL BE MECHANICAL EQUIPMENT AND/OR AIR DEVICES NOTED OR INDICATED FOR RELOCATION SHALL BE REMOVED WITH CARE, CLEANED, REFURBISHED AND STORED IN A PROTECTED SECURE LOCATION DURING DEMOLITION AND CONSTRUCTION. 14. COORDINATE ALL BUILDING SYSTEMS SHUT-DOWN REQUIREMENTS WITH THE VA CFM. IT IS THE COORDINATE ALL BUILDING SYSTEMS SHUT-DOWN REQUIREMENTS WITH THE VA CFM. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COORDINATE AND PROVIDE SYSTEM DRAIN DOWN AND FILL OF THE AFFECTED HVAC AND PLUMBING SYSTEMS PER THE OWNER'S/FACILITY ENGINEER'S REQUIREMENTS. 15. ALL AREAS AFFECTED BY THE CONSTRUCTION SHALL BE MAINTAINED AT A NEGATIVE PRESSURE AT ALL AREAS AFFECTED BY THE CONSTRUCTION SHALL BE MAINTAINED AT A NEGATIVE PRESSURE AT ALL TIMES DURING THE CONSTRUCTION IN ACCORDANCE WITH ICRA (HEALTHCARE CONSTRUCTION STANDARDS). CONTRACTOR SHALL PROVIDE EXHAUST FANS AND TEMPORARY DUCTWORK AS NEEDED TO COMPLY WITH THIS REQUIREMENT. 16. THESE PLANS ARE DIAGRAMMATIC IN NATURE, CONTRACTOR SHALL INCLUDE APPROPRIATE THESE PLANS ARE DIAGRAMMATIC IN NATURE, CONTRACTOR SHALL INCLUDE APPROPRIATE ALLOWANCES FOR OFFSETS AS REQUIRED TO ACCOMMODATE VERTICAL AND HORIZONTAL VARIATIONS IN THE LOCATIONS AND ELEVATIONS OF DUCTWORK, PIPING, AND EXISTING CONDITIONS. 17. WHERE CONNECTION IS MADE TO EXISTING SYSTEMS, FIELD VERIFY EXACT LOCATION, SIZE, AND WHERE CONNECTION IS MADE TO EXISTING SYSTEMS, FIELD VERIFY EXACT LOCATION, SIZE, AND CONNECTION REQUIREMENTS AND PROVIDE ACCORDINGLY. PATCH INSULATION AND OVERLAP VAPOR BARRIER AS APPLICABLE. 18. SIZES INDICATED ON THE EXISTING DUCTWORK AND PIPING ARE PER THE ORIGINAL DOCUMENTS SIZES INDICATED ON THE EXISTING DUCTWORK AND PIPING ARE PER THE ORIGINAL DOCUMENTS AND/OR FIELD MEASUREMENTS. FIELD VERIFY EXACT SIZES AND PROVIDE TRANSITIONS AS NECESSARY. 19. EACH TRADE SHALL COORDINATE THE ROUTING AND INSTALLATION OF HIS WORK WITH THAT OF ALL EACH TRADE SHALL COORDINATE THE ROUTING AND INSTALLATION OF HIS WORK WITH THAT OF ALL OTHER TRADES THROUGH THE GENERAL CONTRACTOR. IN ANY INSTANCES OF CONFLICT, SYSTEMS REQUIRING "GRADE" OR "SLOPE" FOR DRAINAGE (SANITARY SEWER, SANITARY VENT, EQUIPMENT/CONDENSATE DRAINS, ETC.) SHALL HAVE PRIORITY. 20. ALL THERMOSTAT/HUMIDISTAT SENSORS SHALL BE MOUNTED 48" ABOVE FINISHED FLOOR UNLESS ALL THERMOSTAT/HUMIDISTAT SENSORS SHALL BE MOUNTED 48" ABOVE FINISHED FLOOR UNLESS OTHERWISE NOTED. 21. ALL NEW DUCTWORK MUST MEET SMACNA REQUIREMENTS FOR EACH PRESSURE CLASSIFICATION. ALL NEW DUCTWORK MUST MEET SMACNA REQUIREMENTS FOR EACH PRESSURE CLASSIFICATION. 22. PROVIDE TURNING VANES IN ALL DUCTWORK ELBOWS(ANLGED 90 DEGREES) WHETHER OR NOT PROVIDE TURNING VANES IN ALL DUCTWORK ELBOWS(ANLGED 90 DEGREES) WHETHER OR NOT SHOWN ON THE DRAWINGS. 23. ALL BRANCH DUCTWORK TAKE-OFFS INCLUDING THOSE WITH 45 DEGREES FITTINGS SHALL BE ALL BRANCH DUCTWORK TAKE-OFFS INCLUDING THOSE WITH 45 DEGREES FITTINGS SHALL BE PROVIDED WITH MANUAL VOLUME DAMPER WHETHER INDICATED ON THE DRAWINGS OR NOT. PROVIDE STANDOFF BRACKETS FOR INSULATED DUCTS. 24. WHEREVER THE DRAWINGS CALL FOR THE CONTRACTOR TO MEASURE EXISTING AIR QUANTITIES, WHEREVER THE DRAWINGS CALL FOR THE CONTRACTOR TO MEASURE EXISTING AIR QUANTITIES, CONTRACTOR SHALL COMPLETE THE WORK AND SHALL FIRST OBTAIN WRITTEN APPROVAL OF MEASURED AIR QUANTITIES FROM VA, PRIOR TO REMOVAL OF ANY CEILING FOR NEW WORK. FAILURE TO COMPLY WITH THIS REQUIREMENT WILL REQUIRE A RETEST BY THE CONTRACTOR AFTER RETURNING THE SPACE TO ORIGINAL CONDITIONS. 25. CONTRACTOR SHALL PROVIDE TEMPORARY COOLING IN ALL ELECTRICAL ROOMS WHERE THE EXISTING CONTRACTOR SHALL PROVIDE TEMPORARY COOLING IN ALL ELECTRICAL ROOMS WHERE THE EXISTING COOLING OR EXHAUST WILL GET DEMOLISHED AS PART OF THE CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE ELECTRICAL ROOMS AT 80 °F UNTIL SUCH A TIME THAT THETEMPORARY COOLING IS NO LONGER NEEDED BY THE ELECTRICAL EQUIPMENT.
AutoCAD SHX Text POINT OF CHANGE IN DUCT CONSTRUCTION BY STATIC PRESSURE CLASS, THE NUMBER ASSIGNS PRESSURE CLASS (IN. OF WATER) WHICH WILL ACCOMMODATE MAXIMUM OPERATING PRESSURE IN THE DUCT SUBSECTION. THE SYMBOL CONTINUES THE ASSIGNMENT UNTIL THE DUCT TERMINATES OR ANOTHER SYMBOL APPEARS. A "N" SUPERSCRIPT INDICATES NEGATIVE PRESSURE.
AutoCAD SHX Text
LOUVER (LOUVER SPECIFIED IN ARCHITECTURAL SECTION)
AutoCAD SHX Text
STANDARD BRANCH SUPPLY OR RETURN, NO SPLITTER (45° TAP)
AutoCAD SHX Text
DUCT MOUNTED COIL (ELECTRIC)
AutoCAD SHX Text
FLEXIBLE CONNECTION, EQUIPMENT, VIBRATION, OR SEISMIC
AutoCAD SHX Text VANED ELBOW (PROVIDE ALL SQUARE OR RECTANGULAR ELBOWS WITH VANES EVEN IF SYMBOL IS MISSING)
AutoCAD SHX Text
EXHAUST OR RETURN BOTTOM REGISTER OR GRILLE (WALL TYPE)
AutoCAD SHX Text
EXHAUST OR RETURN REGISTER OR TOP GRILLE (WALL TYPE)
AutoCAD SHX Text
INVERTED BUCKET TRAP SET INCLUDING PIPING ACCESSORIES, SEE DETAIL
AutoCAD SHX Text
FLOAT & THERMOSTATIC TRAP SET INCLUDING PIPING ACCESSORIES, SEE DETAIL
AutoCAD SHX Text
THERMOSTATIC TRAP SET INCLUDING PIPING ACCESSORIES, SEE DETAIL
AutoCAD SHX Text H
AutoCAD SHX Text
STROBE AND HORN FOR HIGH TEMPERATURE ALARM
AutoCAD SHX Text
UNIT HEATER (HORIZONTAL)
AutoCAD SHX Text
UNIT HEATER (VERTICAL)
AutoCAD SHX Text
PRESSURE DIFFERENTIAL SENSOR
AutoCAD SHX Text
PD
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
(HOT WATER OR STEAM COIL)
AutoCAD SHX Text
(60 PSIG AND ABOVE)
AutoCAD SHX Text
CONDENSATE RETURN
AutoCAD SHX Text
(16 PSIG THRU 59 PSIG)
AutoCAD SHX Text
CONDENSATE RETURN
AutoCAD SHX Text
(15 PSIG AND BELOW)
AutoCAD SHX Text
CONDENSATE RETURN
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
DN
RAMP
RAMP DN
S
S S
S
S
S
SS
S
S
SSSSS
S S S S S
S
SS S
S S
SS
S S
S
S
S
S
S S S S
S
S SS
S S
S
S
S
S
S
S
S
S
S
S
S S
S
S S S
S
S
S S
22 24
2018161412
V
W
X
Z
AA
BB
2 3 4 5 7 91
U
23 32302826
DD
EE
CC
DD
Z
AA
BB
Y
EE
HH
BUILDING No. 2
PARTIAL GROUND FLOOR DEMOLITION
REFERENCE PLAN - MECHANICAL
1/16" = 1'-0"D1 PARTIAL GROUND FLOOR DEMOLITION REFERENCE PLAN - MECHANICAL
BH IR
A-MDH100
0 8'-0" 16'-0" 32'-0"
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
Key Plan
Balance of Work
9/12/2022
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
GATE A
AutoCAD SHX Text
UP
AutoCAD SHX Text
RAMP DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
RAMP UP
AutoCAD SHX Text
MDH101
AutoCAD SHX Text
MDH102
AutoCAD SHX Text
MDH101
AutoCAD SHX Text
MDH103
AutoCAD SHX Text
CSSSD
AutoCAD SHX Text G580
AutoCAD SHX Text
ELEC
AutoCAD SHX Text 0165S
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text 0168S
AutoCAD SHX Text
ELEC
AutoCAD SHX Text 0167S
AutoCAD SHX Text G191S
AutoCAD SHX Text
SECURITY RM.
AutoCAD SHX Text 0202S
AutoCAD SHX Text
SPECIMEN CLOS
AutoCAD SHX Text 0170S
AutoCAD SHX Text
SPECIMEN STORAGE
AutoCAD SHX Text 0171S
AutoCAD SHX Text
AUTOPSY
AutoCAD SHX Text 0169S
AutoCAD SHX Text
REFR. MORTUARY
AutoCAD SHX Text 0166S
AutoCAD SHX Text
EMBALMING
AutoCAD SHX Text 0167S
AutoCAD SHX Text
VEST
AutoCAD SHX Text 0166S
AutoCAD SHX Text
SHR
AutoCAD SHX Text G193S
AutoCAD SHX Text
TOILET
AutoCAD SHX Text G190S
AutoCAD SHX Text
VEST
AutoCAD SHX Text 0199S
AutoCAD SHX Text
CLERGY
AutoCAD SHX Text 0163S
AutoCAD SHX Text
ALTAR
AutoCAD SHX Text 0162S
AutoCAD SHX Text
ELEV.MACH. RM.
AutoCAD SHX Text
0203AS
AutoCAD SHX Text
STAFF TOILET
AutoCAD SHX Text
0202BS
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0202S
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
0202AS
AutoCAD SHX Text
CANTEEN STORAGE
AutoCAD SHX Text
0252EA
AutoCAD SHX Text
IRM STORAGE
AutoCAD SHX Text
0252EB
AutoCAD SHX Text
VAULT 2
AutoCAD SHX Text 0253E
AutoCAD SHX Text
PHARMACY DRUG CACHE
AutoCAD SHX Text 0255E
AutoCAD SHX Text
VAULT 2
AutoCAD SHX Text 0253E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0257E
AutoCAD SHX Text
FORMER GENERATOR RM
AutoCAD SHX Text 0272N
AutoCAD SHX Text
SPS RECEIVING
AutoCAD SHX Text 0263N
AutoCAD SHX Text
SPS
AutoCAD SHX Text 0264N
AutoCAD SHX Text
SUPPLY STORAGE
AutoCAD SHX Text 0253N
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0253E
AutoCAD SHX Text
EQUIPMENT STOR
AutoCAD SHX Text 0252E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0271N
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 0270N
AutoCAD SHX Text
FANS
AutoCAD SHX Text 0269N
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0262N
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-2
AutoCAD SHX Text
EMS SUPER
AutoCAD SHX Text 0255N
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 0244N
AutoCAD SHX Text
ELEC RM
AutoCAD SHX Text 0247N
AutoCAD SHX Text
LINEN CHUTE RM
AutoCAD SHX Text 0253E
AutoCAD SHX Text
MAIN ELECTRIC-BUILDING 1
AutoCAD SHX Text 0242N
AutoCAD SHX Text
ELEC CL
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text 0253F
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text 0233E
AutoCAD SHX Text
FOOD RECEIVING
AutoCAD SHX Text 0218E
AutoCAD SHX Text
INGREDIENT CONTROL
AutoCAD SHX Text 0216E
AutoCAD SHX Text
MATERIAL OFFICE
AutoCAD SHX Text 0215E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0243N
AutoCAD SHX Text
IT ROOM
AutoCAD SHX Text 0211E
AutoCAD SHX Text
EMPTY GAS CYLINDERS
AutoCAD SHX Text 0210E
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0212E
AutoCAD SHX Text
SERVICE ENTRY
AutoCAD SHX Text 0211E
AutoCAD SHX Text
COMP GAS
AutoCAD SHX Text
AutoCAD SHX Text
NON FLAM GAS
AutoCAD SHX Text
AutoCAD SHX Text
EQUIPMENT STORAGE
AutoCAD SHX Text 0203E
AutoCAD SHX Text
S P D WAREHOUSE
AutoCAD SHX Text 0250E
AutoCAD SHX Text
EMS EQUIPMENT RM
AutoCAD SHX Text 0251E
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
GOOD RECEIVING
AutoCAD SHX Text 0214E
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text 0213E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0242N
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0241N
AutoCAD SHX Text
STAIRWELL
AutoCAD SHX Text 0254N
AutoCAD SHX Text
PLUMBING EQUIP RM
AutoCAD SHX Text G583
AutoCAD SHX Text
SECURE STORAGE
AutoCAD SHX Text G586
AutoCAD SHX Text
BREAKDOWN
AutoCAD SHX Text G590
AutoCAD SHX Text
EQUIP HOLDING / DISPATCH
AutoCAD SHX Text G595
AutoCAD SHX Text
SOILED RECEIVING
AutoCAD SHX Text G591
AutoCAD SHX Text
MECH RM
AutoCAD SHX Text G703
AutoCAD SHX Text
JAN.
AutoCAD SHX Text G598
AutoCAD SHX Text
MALE TOILET
AutoCAD SHX Text G382
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
ELEV LOBBY
AutoCAD SHX Text G001
AutoCAD SHX Text
IT
AutoCAD SHX Text
0209SA
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 0209S
AutoCAD SHX Text
RADIOACTIVE RM
AutoCAD SHX Text G206S
AutoCAD SHX Text
RAD WASTE
AutoCAD SHX Text 0253G
AutoCAD SHX Text
STAFF CLOTHING RM
AutoCAD SHX Text G201S
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
G204BS
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text 0184S
AutoCAD SHX Text
REGULATED MEDICAL WASTE
AutoCAD SHX Text G204S
AutoCAD SHX Text
INTERIM STORAGE
AutoCAD SHX Text G205S
AutoCAD SHX Text
RADIOACTIVE GAS METER
AutoCAD SHX Text
G204AS
AutoCAD SHX Text
PAINT SHOP
AutoCAD SHX Text 0203S
AutoCAD SHX Text
PAINT SHOP
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 0203S
AutoCAD SHX Text
PUMPS
AutoCAD SHX Text 0166S
AutoCAD SHX Text
PUMP ROOM
AutoCAD SHX Text 0175S
AutoCAD SHX Text
FIRE COMMAND / ATS SWITCH
AutoCAD SHX Text 0273N
AutoCAD SHX Text
EQUIPMENT HOLDING
AutoCAD SHX Text
0230AE
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text G245N
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-1
AutoCAD SHX Text
PE #5
AutoCAD SHX Text
PE #6
AutoCAD SHX Text
PE #7
AutoCAD SHX Text
PE #8
AutoCAD SHX Text
SE #12
AutoCAD SHX Text
SE #11
AutoCAD SHX Text
SE #10
AutoCAD SHX Text
SE #9
AutoCAD SHX Text
SE #13
AutoCAD SHX Text
STAIRS #3
AutoCAD SHX Text G2189S
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #1
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #2
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #3
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
0264AN
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
KEYED NOTES:#
MA
TC
H
LIN
E
- S
EE
A
-M
DH
3 F
OR
C
ON
T.
Z
U
DN
RAMP
33 35
AA
V
W
X
EX
EX
S
S
SSSSS
S S S S S
S
SS S
S S
SS
S S
S
S
S
S
S S S S
S
S SS
S
S
S
S
S
S
S
AA
EX
S S
MATCH LINE - SEE A-MDH102 FOR CONT.
161412 32302818 20 22 23 24 2611
EX EX EX EX EX EX
GENERAL NOTES:
Y
V
W
X
Z
AA
U
D1 1/8" = 1'-0"
PARTIAL GROUND FLOOR DEMO PLAN - PART A - MECHANICAL
0 4'-0" 8'-0" 16'-0"
PARTIAL GROUND FLOOR DEMO PLAN - PART
A - MECHANICAL
A-MDH101
BH IR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
Key Plan
Balance of Work
9/12/2022
PLAN
NORTH
AutoCAD SHX Text
1. DISCONNECT AND REMOVE EXHAUST FAN LOCATED AT ROOF AND ITS DISCONNECT AND REMOVE EXHAUST FAN LOCATED AT ROOF AND ITS ASSOCIATED, REGISTER, DUCTWORK, AND CONTROLS IN ITS ENTIRETY. ROOF OPENING TO BE ENLARGED AND REUSED FOR NEW ROOF MOUNTED EXHAUST FAN AND DUCTWORK. SEE NEW WORK PLAN FOR ADDITIONAL INFORMATION. 2. DISCONNECT AND REMOVE FLOOR MOUNTED COOLING UNIT, DUCTWORK, DISCONNECT AND REMOVE FLOOR MOUNTED COOLING UNIT, DUCTWORK, HANGERS, AND CONTROLS IN ITS ENTIRETY. SEE PIPING DEMOLITION PLANS FOR EXTENT OF PIPING TO BE REMOVED. 3. DISCONNECT AND REMOVE IN-LINE EXHAUST FAN AND ASSOCIATED HANGERS DISCONNECT AND REMOVE IN-LINE EXHAUST FAN AND ASSOCIATED HANGERS AND CONTROLS IN ITS ENTIRETY. 4. REMOVE DUCTWORK AND ASSOCIATED HANGER SUPPORTS BACK TO LOCATION REMOVE DUCTWORK AND ASSOCIATED HANGER SUPPORTS BACK TO LOCATION INDICATED AND CAP AND INSULATE REMAINING DUCT OPENING. 5. DISCONNECT AND REMOVE WALL MOUNTED PROPELLER FAN AND ASSOCIATED DISCONNECT AND REMOVE WALL MOUNTED PROPELLER FAN AND ASSOCIATED DAMPER, SUPPORTS, AND CONTROLS IN ITS ENTIRETY. REPAIR WALL OPENING TO MATCH EXISTING CONSTRUCTION. 6. REMOVE DUCT TO UNDERSIDE OF CEILING SLAB AND CAP AND INSULATE REMOVE DUCT TO UNDERSIDE OF CEILING SLAB AND CAP AND INSULATE REMAINING DUCT OPENING. 7. DISCONNECT AND REMOVE SPLIT SYSTEM COOLING UNIT AND ASSOCIATED DISCONNECT AND REMOVE SPLIT SYSTEM COOLING UNIT AND ASSOCIATED DUCTWORK, HANGERS, AND DRAIN PAN IN ITS ENTIRETY. 8. MEASURE EXISTING AIR QUANTITY AT AHU FAN SUPPLY, RETURN FAN, AND MEASURE EXISTING AIR QUANTITY AT AHU FAN SUPPLY, RETURN FAN, AND CEILING AIR SUPPLY DIFFUSER/RETURN GRILLE BEFORE REMOVAL OF CEILING AND PROVIDE REPORT TO VA CFM. DISCONNECT AND REMOVE CEILING DIFFUSER/RETURN GRILLE WHEN CEILING IS REMOVED AND TEMPORARILY CAP THE DUCT CONNECTIONS FOR REINSTALLATION. UPON COMPLETION OF NEW CEILING GRID, REINSTALL AND RECONNECT DIFFUSER/RETURN GRILLE AND REBALANCE AIR FLOW QUANTITIES TO CFM AS SHOWN ON NEW WORK PLAN. CONTRACTOR SHALL FIRST OBTAIN WRITTEN APPROVAL OF MEASURED AIR QUANTITIES FROM VA, PRIOR TO REMOVAL OF ANY CEILING FOR NEW WORK. FAILURE TO COMPLY WITH THIS REQUIREMENT WILL REQUIRE A RETEST BY THE CONTRACTOR AFTER RETURNING THE SPACE TO ORIGINAL CONDITIONS. 9. MEASURE AIR SUPPLY/RETURN QUANTITY AT THESE LOCATIONS ALONG WITH MEASURE AIR SUPPLY/RETURN QUANTITY AT THESE LOCATIONS ALONG WITH MEASUREMENTS OF DIFFUSERS/GRILLES IN NOTE 8 ABOVE AND ADD TO AIRFLOW REPORT. CONTRACTOR SHALL FIRST OBTAIN WRITTEN APPROVAL OF MEASURED AIR QUANTITIES FROM VA, PRIOR TO REMOVAL OF ANY CEILING FOR NEW WORK. FAILURE TO COMPLY WITH THIS REQUIREMENT WILL REQUIRE A RETEST BY THE CONTRACTOR AFTER RETURNING THE SPACE TO ORIGINAL CONDITIONS. 10. DISCONNECT AND REMOVE WALL MOUNTED PROPELLER FAN AND DISCONNECT AND REMOVE WALL MOUNTED PROPELLER FAN AND ASSOCIATED CONTROLS. 11. DISCONNECT DUCT PLENUMS FROM LOUVERS AS NECESSARY FOR DISCONNECT DUCT PLENUMS FROM LOUVERS AS NECESSARY FOR REMOVAL AND INSTALLATION OF NEW LOUVERS UNDER DIVISION 8. RECONNECT AND RESEAL DUCT PLENUM CONNECTIONS AFTER INSTALLATION OF NEW LOUVERS. 12. ELECTRICAL DEMOLITION OF EXISTING CONDUITS/RACEWAYS IN THIS ELECTRICAL DEMOLITION OF EXISTING CONDUITS/RACEWAYS IN THIS SPACE MUST OCCUR PRIOR TO INSTALLATION OF NEW DUCTWORK TO PROVIDE NEEDED SPACE REQUIREMENTS. REFER TO ELECTRICAL DRAWINGS AND COORDINATE WITH ELECTRICAL CONTRACTOR. 13. CONTRACTOR SHALL PROVIDE TEMPORARY COOLING. CONTRACTOR IS CONTRACTOR SHALL PROVIDE TEMPORARY COOLING. CONTRACTOR IS RESPONSIBLE FOR MAINTAINING THE ELECTRICAL ROOMS AT 80 °F UNTIL SUCHA TIME THAT THE TEMPORARY COOLING IS NO LONGER NEEDED BY THE ELECTRICAL EQUIPMENT.
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0257E
AutoCAD SHX Text
FORMER GENERATOR RM
AutoCAD SHX Text 0272N
AutoCAD SHX Text
SPS RECEIVING
AutoCAD SHX Text 0263N
AutoCAD SHX Text
SPS
AutoCAD SHX Text 0264N
AutoCAD SHX Text
SUPPLY STORAGE
AutoCAD SHX Text 0253N
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0253E
AutoCAD SHX Text
EQUIPMENT STOR
AutoCAD SHX Text 0252E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0271N
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0271N
AutoCAD SHX Text
FANS
AutoCAD SHX Text 0269N
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0262N
AutoCAD SHX Text
EMS SUPER
AutoCAD SHX Text 0255N
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 0244N
AutoCAD SHX Text
ELEC RM
AutoCAD SHX Text 0247N
AutoCAD SHX Text
LINEN CHUTE RM
AutoCAD SHX Text 0253E
AutoCAD SHX Text
MAJOR ELEC EQUIPMENT
AutoCAD SHX Text 0242N
AutoCAD SHX Text
ELEC CL
AutoCAD SHX Text
INGREDIENT CONTROL
AutoCAD SHX Text 0216E
AutoCAD SHX Text
MATERIAL OFFICE
AutoCAD SHX Text 0215E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0243N
AutoCAD SHX Text
IT ROOM
AutoCAD SHX Text 0211E
AutoCAD SHX Text
EMPTY GAS CYLINDERS
AutoCAD SHX Text 0210E
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 0212E
AutoCAD SHX Text
SERVICE ENTRY
AutoCAD SHX Text 0211E
AutoCAD SHX Text
COMP GAS
AutoCAD SHX Text
AutoCAD SHX Text
NON FLAM GAS
AutoCAD SHX Text
AutoCAD SHX Text
EQUIPMENT STORAGE
AutoCAD SHX Text 0203E
AutoCAD SHX Text
S P D WAREHOUSE
AutoCAD SHX Text 0250E
AutoCAD SHX Text
EMS EQUIPMENT RM
AutoCAD SHX Text 0251E
AutoCAD SHX Text
LOADING DOCK
AutoCAD SHX Text
AutoCAD SHX Text
GOOD RECEIVING
AutoCAD SHX Text 0214E
AutoCAD SHX Text
SUPPLY
AutoCAD SHX Text 0213E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0242N
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0296N
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0241N
AutoCAD SHX Text
STAIRWELL
AutoCAD SHX Text 0254N
AutoCAD SHX Text
EQUIPMENT HOLDING
AutoCAD SHX Text
0230AE
AutoCAD SHX Text G245N
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-2
AutoCAD SHX Text G586
AutoCAD SHX Text
MALE TOILET
AutoCAD SHX Text G382
AutoCAD SHX Text
AutoCAD SHX Text
IT (TR-D)
AutoCAD SHX Text
0209SA
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 0209S
AutoCAD SHX Text
PUMP ROOM
AutoCAD SHX Text 0175S
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SE #12
AutoCAD SHX Text
SE #11
AutoCAD SHX Text
SE #10
AutoCAD SHX Text
SE #9
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #1
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #2
AutoCAD SHX Text 30x30
AutoCAD SHX Text 18x4
AutoCAD SHX Text 20x12
AutoCAD SHX Text 16"
AutoCAD SHX Text 14x8
AutoCAD SHX Text 26x22
AutoCAD SHX Text 24x24
AutoCAD SHX Text 20x12
AutoCAD SHX Text 24x12
AutoCAD SHX Text 12x6
AutoCAD SHX Text 44x12
AutoCAD SHX Text 24x12 DN
AutoCAD SHX Text 24x24 UP
AutoCAD SHX Text
6" UP
AutoCAD SHX Text 26x22 UP
AutoCAD SHX Text 18x16
AutoCAD SHX Text 24x16
AutoCAD SHX Text 26x15 DN
AutoCAD SHX Text 26x12
AutoCAD SHX Text 24x16
AutoCAD SHX Text 6x16
AutoCAD SHX Text
18" UP
AutoCAD SHX Text 12x5
AutoCAD SHX Text 24x12
AutoCAD SHX Text 12x12
AutoCAD SHX Text 44x12
AutoCAD SHX Text 36x18
AutoCAD SHX Text 22x12
AutoCAD SHX Text 12x18
AutoCAD SHX Text 10x12
AutoCAD SHX Text 14x10
AutoCAD SHX Text 14x6
AutoCAD SHX Text 24x8
AutoCAD SHX Text 12x6
AutoCAD SHX Text 14x8
AutoCAD SHX Text 24x20 RA
AutoCAD SHX Text 22x16
AutoCAD SHX Text 24x16 SA
AutoCAD SHX Text 28x20
AutoCAD SHX Text 28x20 RA
AutoCAD SHX Text 16x12 SA
AutoCAD SHX Text 12x10 SA
AutoCAD SHX Text 18x12 SA
AutoCAD SHX Text 12x5 RA
AutoCAD SHX Text 16x8 RA
AutoCAD SHX Text 12x7 RA
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text 8x6
AutoCAD SHX Text 28x20 RA
AutoCAD SHX Text 8x8
AutoCAD SHX Text 12x8
AutoCAD SHX Text 16x6
AutoCAD SHX Text 12x8
AutoCAD SHX Text 16x12
AutoCAD SHX Text 19x12
AutoCAD SHX Text 10x6
AutoCAD SHX Text 22x14
AutoCAD SHX Text 14x12
AutoCAD SHX Text 6"
AutoCAD SHX Text 46x12
AutoCAD SHX Text 24x10
AutoCAD SHX Text 14x6
AutoCAD SHX Text 24x10
AutoCAD SHX Text 18x11
AutoCAD SHX Text 18x11
AutoCAD SHX Text 18x9
AutoCAD SHX Text 18x8
AutoCAD SHX Text 18x8
AutoCAD SHX Text 16x12
AutoCAD SHX Text 14x12
AutoCAD SHX Text 8x8
AutoCAD SHX Text 12x12
AutoCAD SHX Text 14x4
AutoCAD SHX Text 31x13
AutoCAD SHX Text
4" FLEX
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 10"
AutoCAD SHX Text 10"
AutoCAD SHX Text 12"
AutoCAD SHX Text 10"
AutoCAD SHX Text 12x4 SA
AutoCAD SHX Text D
AutoCAD SHX Text 10"
AutoCAD SHX Text 32x18
AutoCAD SHX Text
1. SEE SHEET A-M001 FOR MECHANICAL SYMBOLS AND ABBREVIATIONS SEE SHEET A-M001 FOR MECHANICAL SYMBOLS AND ABBREVIATIONS 2. WHERE APPLICABLE, REFER TO DRAWING A-GI001 FOR FIRE AND SMOKE WHERE APPLICABLE, REFER TO DRAWING A-GI001 FOR FIRE AND SMOKE BARRIER WALL LEGEND.
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
KEYED NOTES:#GENERAL NOTES:
EE
161412
AA
BB
323028
DD
EE
BB
AA
DD
EE
DD
BB
18 20 22 23 24 2611
RAMP DN
EX EX EX EX EX EX
EX
EX
EX
EX
EX
EX
EX
AA
EX
MATCH LINE - SEE A-MDH101 FOR CONT.
D1 1/8" = 1'-0"
PARTIAL GROUND FLOOR DEMO PLAN - PART B - MECHANICAL
PARTIAL GROUND FLOOR DEMO PLAN - PART
B - MECHANICAL
A-MDH102
TM/BH IR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
Key Plan
Balance of Work
9/12/2022
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
AutoCAD SHX Text
1. REMOVE DUCTWORK AND HANGERS UP TO LOUVER CONNECTION. REMOVE DUCTWORK AND HANGERS UP TO LOUVER CONNECTION. 2. DISCONNECT AND REMOVE CEILING HUNG FAN COIL UNIT, ASSOCIATED DISCONNECT AND REMOVE CEILING HUNG FAN COIL UNIT, ASSOCIATED DUCTWORK, DRIP PAN, SUPPORTS, AND CONTROLS IN ITS ENTIRETY. SEE PIPING DEMOLITION PLAN FOR EXTENT OF PIPE REMOVAL. 3. DISCONNECT AND REMOVE IN-LINE EXHAUST FAN, ASSOCIATED HANGERS, AND DISCONNECT AND REMOVE IN-LINE EXHAUST FAN, ASSOCIATED HANGERS, AND CONTROLS IN ITS ENTIRETY. 4. DISCONNECT AND REMOVE WALL MOUNTED FAN, DAMPER, CONTROLS, AND DISCONNECT AND REMOVE WALL MOUNTED FAN, DAMPER, CONTROLS, AND ASSOCIATED DUCTWORK AND HANGERS IN ITS ENTIRETY. 5. DISCONNECT AND REMOVE EXISTING WALL MOUNTED PROPELLER FAN, DISCONNECT AND REMOVE EXISTING WALL MOUNTED PROPELLER FAN, ASSOCIATED SHEET METAL, DAMPER, SUPPORTS, CONTROLS, AND LOUVER OPENING IN ITS ENTIRETY. 6. REMOVE DUCTWORK, HANGERS, AND LOUVER ABOVE DOOR FRAME. REMOVE DUCTWORK, HANGERS, AND LOUVER ABOVE DOOR FRAME. 7. REMOVE EXHAUST HOOD AND ASSOCIATED DUCTWORK IN IT'S ENTIRETY. REMOVE EXHAUST HOOD AND ASSOCIATED DUCTWORK IN IT'S ENTIRETY. 8. REMOVE DUCT UP TO UNDERSIDE OF CEILING SLAB AND CAP AND INSULATE REMOVE DUCT UP TO UNDERSIDE OF CEILING SLAB AND CAP AND INSULATE CEILING SLAB OPENING WATER TIGHT. 9. DISCONNECT AND REMOVE FLOOR MOUNTED CABINET FAN, CONTROLS, AND DISCONNECT AND REMOVE FLOOR MOUNTED CABINET FAN, CONTROLS, AND ASSOCIATED DUCTWORK CONNECTING TO CRAWL SPACE FLOOR OPENING IN ITS ENTIRETY.
AutoCAD SHX Text
1. SEE SHEET A-M001 FOR MECHANICAL SYMBOLS AND ABBREVIATIONS SEE SHEET A-M001 FOR MECHANICAL SYMBOLS AND ABBREVIATIONS 2. WHERE APPLICABLE, REFER TO DRAWING A-GI001 FOR FIRE AND SMOKE WHERE APPLICABLE, REFER TO DRAWING A-GI001 FOR FIRE AND SMOKE BARRIER WALL LEGEND.
AutoCAD SHX Text
CANTEEN STORAGE
AutoCAD SHX Text
0252EA
AutoCAD SHX Text
IRM STORAGE
AutoCAD SHX Text
0252EB
AutoCAD SHX Text
VAULT 2
AutoCAD SHX Text 0253E
AutoCAD SHX Text
PHARMACY DRUG CACHE
AutoCAD SHX Text 0255E
AutoCAD SHX Text
VAULT 2
AutoCAD SHX Text 0253E
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0257E
AutoCAD SHX Text
REFRIGERATOR
AutoCAD SHX Text 0253F
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text 0233E
AutoCAD SHX Text
FOOD RECEIVING
AutoCAD SHX Text 0218E
AutoCAD SHX Text
INGREDIENT CONTROL
AutoCAD SHX Text 0216E
AutoCAD SHX Text 10x14
AutoCAD SHX Text 30x30
AutoCAD SHX Text 20x9
AutoCAD SHX Text 20x12
AutoCAD SHX Text 16"
AutoCAD SHX Text 12x18
AutoCAD SHX Text 46x18
AutoCAD SHX Text 30x30
AutoCAD SHX Text 18x16
AutoCAD SHX Text 20x9
AutoCAD SHX Text 30x30 UP THROUGH CEILING SLAB
AutoCAD SHX Text 60x30
AutoCAD SHX Text 36x32
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-1
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
SE #13
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #2
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
DOCK LEVELER
AutoCAD SHX Text #3
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
RAMP UP
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
U
V
W
2 3 4 5 7 9
U
Y
S
S S
S S
S S
X
MA
TC
H
LIN
E
- S
EE
A
-M
DH
1 F
OR
C
ON
T.
GENERAL NOTES:
PARTIAL GROUND FLOOR DEMO PLAN - PART
C- MECHANICAL
A-MDH103
TM/BH IR
C3 1/8" = 1'-0"
PARTIAL GROUND FLOOR DEMO PLAN - PART C- MECHANICAL
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Fi le
P at h 6/
/2
:3
9:
P M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
Key Plan
Balance of Work
9/12/2022
0 4'-0" 8'-0" 16'-0"
PLAN
NORTH
AutoCAD SHX Text
1. DISCONNECT AND REMOVE CEILING HUNG MAKE UP AIR UNIT AND ASSOCIATED DISCONNECT AND REMOVE CEILING HUNG MAKE UP AIR UNIT AND ASSOCIATED DUCTWORK, LOUVER, DRIP PAN, AND CONTROLS IN THEIR ENTIRETY. 2. REMOVE ABANDONED DUCTWORK AND ASSOCIATED LOUVER. REMOVE ABANDONED DUCTWORK AND ASSOCIATED LOUVER. 3. REMOVE MAKEUP AIR UNIT DUCT BRANCH TO LOCATION SHOWN AND INSULATE REMOVE MAKEUP AIR UNIT DUCT BRANCH TO LOCATION SHOWN AND INSULATE AND CAP DUCT OPENING OF DUCTWORK TO REMAIN. 4. REMOVE PTAC UNIT, ASSOCIATED DUCTWORK AND LOUVER.REMOVE PTAC UNIT, ASSOCIATED DUCTWORK AND LOUVER.
AutoCAD SHX Text
RADIOACTIVE RM
AutoCAD SHX Text G206S
AutoCAD SHX Text
RAD WASTE
AutoCAD SHX Text 0253G
AutoCAD SHX Text
STAFF CLOTHING RM
AutoCAD SHX Text G201S
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text
G204BS
AutoCAD SHX Text
REGULATED MEDICAL WASTE
AutoCAD SHX Text G204S
AutoCAD SHX Text
INTERIM STORAGE
AutoCAD SHX Text G205S
AutoCAD SHX Text
RADIOACTIVE GAS METER
AutoCAD SHX Text
G204AS
AutoCAD SHX Text
PAINT SHOP
AutoCAD SHX Text 0203S
AutoCAD SHX Text
PAINT SHOP STOR
AutoCAD SHX Text 0203S
AutoCAD SHX Text
ELEC
AutoCAD SHX Text 0165S
AutoCAD SHX Text
LOCKERS
AutoCAD SHX Text 0168S
AutoCAD SHX Text
ELEC
AutoCAD SHX Text 0167S
AutoCAD SHX Text G191S
AutoCAD SHX Text
SECURITY RM.
AutoCAD SHX Text 0202S
AutoCAD SHX Text
SPECIMEN STORAGE
AutoCAD SHX Text 0171S
AutoCAD SHX Text 0169S
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text 0166S
AutoCAD SHX Text
SHR
AutoCAD SHX Text G193S
AutoCAD SHX Text
TOILET
AutoCAD SHX Text G190S
AutoCAD SHX Text
VEST
AutoCAD SHX Text 0199S
AutoCAD SHX Text
ELEV.MACH. RM.
AutoCAD SHX Text
0203AS
AutoCAD SHX Text
STAFF TOILET
AutoCAD SHX Text
0202BS
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 0202S
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
0202AS
AutoCAD SHX Text
IT (TR-D)
AutoCAD SHX Text
0209SA
AutoCAD SHX Text
LAUNDRY
AutoCAD SHX Text 0184S
AutoCAD SHX Text
PUMPS
AutoCAD SHX Text 0166S
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
STAIRS #3
AutoCAD SHX Text G2189S
AutoCAD SHX Text Open
AutoCAD SHX Text to Above
AutoCAD SHX Text to Above
AutoCAD SHX Text Open
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
RAMP DN
AutoCAD SHX Text
SECURITY CONTROL
AutoCAD SHX Text
RM. (POST 7)
AutoCAD SHX Text 0200S
AutoCAD SHX Text 46x24
AutoCAD SHX Text 16x20
AutoCAD SHX Text 12x10
AutoCAD SHX Text 16x10
AutoCAD SHX Text 54x12
AutoCAD SHX Text 46x12
AutoCAD SHX Text 24x10
AutoCAD SHX Text 16x10
AutoCAD SHX Text
4" FLEX
AutoCAD SHX Text
1. SEE SHEET A-M001 FOR MECHANICAL SYMBOLS AND…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .