C-Fire Protection- Part 2.pdf
PDF 4 MB Posted
- Solicitation number
- QSE--36C10F24R50018
About this file
This document appears to be a set of construction drawings and specifications for the Manhattan Hurricane Sandy Recovery Program Balance of Work at the VAMC Manhattan Campus of the VA NY Healthcare System. The drawings cover the renovation and upgrade of the electrical and fire protection systems, including a new generator platform, sprinkler system, and fire alarm system. Key details include the required demolition and installation of new electrical switchgear, transformers, generator controls, and fire alarm panels and devices. The construction is being managed by the Department of Veterans Affairs Office of Construction and Facilities Management under solicitation number QSE-36C10F24R50018. The drawings indicate this work is part of a larger construction project for the VA NY Healthcare System.
View the file
Other files
Show 40 more
Latest 50 of 281 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENSET #2
GEN-2
GENSET #3
GEN-3
PARALLELING SWITCHGEAR ROOM
PSR-1
BLDG. #5 MAIN ELECTRIC ROOM
MER-5
20.5
22.8 22.9
20.5
22.8
18.1 22.9
DD.8
EE
20 22 23
EX
EX
EX
EX
EX EX
EX
EX.
13 15
18 20 22 23 24 26
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
PARTIAL FIRST FLOOR PLAN - GENERATOR PLATFORM
F4
PLAN
NORTH
AutoCAD SHX Text
GENERATORS
AutoCAD SHX Text
MASTER
AutoCAD SHX Text
CONTROLS
AutoCAD SHX Text
(GMC)
AutoCAD SHX Text
GEN 1
AutoCAD SHX Text
GEN 2
AutoCAD SHX Text
GEN 3
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
SPACE FOR PANELS
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
FOR BATTERY RACK
AutoCAD SHX Text
DN
AutoCAD SHX Text D
AutoCAD SHX Text C.1
AutoCAD SHX Text C
AutoCAD SHX Text B.4
AutoCAD SHX Text B
AutoCAD SHX Text A.8
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2.8
AutoCAD SHX Text
AutoCAD SHX Text 3.8
AutoCAD SHX Text
AutoCAD SHX Text 3.5
AutoCAD SHX Text
AutoCAD SHX Text 3"
AutoCAD SHX Text 4"
AutoCAD SHX Text 3"
AutoCAD SHX Text 4"
AutoCAD SHX Text D
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 4"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text E
AutoCAD SHX Text 3"
AutoCAD SHX Text E
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER PLANT ENGINEER OFFICE
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
ENGINEER OFFICE
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-F111
AutoCAD SHX Text M1.3
AutoCAD SHX Text M1.4
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text 3"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 3"
AutoCAD SHX Text M1.5
AutoCAD SHX Text 3"
AutoCAD SHX Text D
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text D1
AutoCAD SHX Text D2
AutoCAD SHX Text 3"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 LOCATION OF EXISTING 3-INCH DRY PIPE VALVE SERVING EXISTING DRY-PIPE SPRINKLER SYSTEM FOR LOCATION OF EXISTING 3-INCH DRY PIPE VALVE SERVING EXISTING DRY-PIPE SPRINKLER SYSTEM FOR TRANSFORMER VAULT IN BUILDING 5. SHOWN FOR REFERENCE ONLY.
AutoCAD SHX Text 2 EXISTING 4-INCH STANDPIPE CONNECTION TO FIRE HOSE VALVE.EXISTING 4-INCH STANDPIPE CONNECTION TO FIRE HOSE VALVE.
AutoCAD SHX Text 3 PROVIDE PIPING EXPANSION JOINT FOR SEISMIC SEPARATION BETWEEN BUILDINGS. FITTINGS SHALL BE PROVIDE PIPING EXPANSION JOINT FOR SEISMIC SEPARATION BETWEEN BUILDINGS. FITTINGS SHALL BE WATERPROOF SEISMIC WALL-PENETRATION TYPE. EXTERIOR PIPING, FITTINGS, AND HANGERS EXPOSED TO OUTSIDE WEATHER SHALL BE PROTECTED FROM CORROSION IN ACCORDANCE WITH NFPA 13, SECTION CORROSION IN ACCORDANCE WITH NFPA 13, SECTION 16.4.2.
AutoCAD SHX Text 4 NEW 3-INCH DRY PIPE VALVE SERVING NEW DRY-PIPE SPRINKLER SYSTEM FOR SWITCHGEAR VAULT ON NEW 3-INCH DRY PIPE VALVE SERVING NEW DRY-PIPE SPRINKLER SYSTEM FOR SWITCHGEAR VAULT ON GENERATOR PLATFORM. SPRINKLER DRAIN TO BE PIPED ALONG RAISED SLAB AND TO SPILL TO THE NEAREST FLOOR DRAIN.
AutoCAD SHX Text 5 GENERATOR ENCLOSURES ARE NOT EQUIPPED WITH AUTOMATIC SPRINKLER PROTECTION. GENERATOR GENERATOR ENCLOSURES ARE NOT EQUIPPED WITH AUTOMATIC SPRINKLER PROTECTION. GENERATOR ENCLOSURES WILL BE PROTECTED WITH AUTOMATIC HEAT DETECTION MONITORED BY THE FIRE ALARM SYSTEM AS APPROVED IN PREVIOUS DESIGNS PER VA FP DESIGN MANUAL SECTION 7.4.E. SEE FIRE ALARM DRAWINGS FOR FURTHER DETAIL.
AutoCAD SHX Text 6 ALL NEW EXPOSED SPRINKLER PIPING TO BE PAINTED RED.ALL NEW EXPOSED SPRINKLER PIPING TO BE PAINTED RED.
AutoCAD SHX Text 7 EXISTING FLOOR DRAIN TO BE EQUIPPED TO RECEIVE SPRINKLER DRAIN DISCHARGE. PROVIDE HARD EXISTING FLOOR DRAIN TO BE EQUIPPED TO RECEIVE SPRINKLER DRAIN DISCHARGE. PROVIDE HARD PIPE FROM NEW DRY VALVE MAIN DRAIN TO THIS PIPE. ENSURE PIPING IS TUCKED NEXT TO EXISTING CEMENT PADS IN ROOM AND DOES NOT CREATE A TRIPPING HAZARD.
AutoCAD SHX Text 8 RUN SPRINKLER PIPE HIGH ABOVE NEW STAIRWELL ENCLOSURE. SPRINKLER PIPE TO ENTER SWITCHGEAR RUN SPRINKLER PIPE HIGH ABOVE NEW STAIRWELL ENCLOSURE. SPRINKLER PIPE TO ENTER SWITCHGEAR ROOM AT CEILING LEVEL. ADJUST PIPING ELEVATION IN BUILDING 4 CHILLER ROOM TO THE SAME ELEVATION AS THE CEILING LEVEL OF SWITCHGEAR ROOM.
AutoCAD SHX Text
1. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS. 2. PROVIDE NEW HEADS AND SPRINKLER PIPING WITHIN THE PARALLEL SWITCHGEAR PROVIDE NEW HEADS AND SPRINKLER PIPING WITHIN THE PARALLEL SWITCHGEAR ROOM. 3. RECONNECT TO EXISTING SPRINKLERS THAT CROSS BOUNDARY OF AREA OF RECONNECT TO EXISTING SPRINKLERS THAT CROSS BOUNDARY OF AREA OF RENOVATION. 4. PAINT ALL EXPOSED FIRE PROTECTION PIPING RED INCLUDING THREADED PIPE PAINT ALL EXPOSED FIRE PROTECTION PIPING RED INCLUDING THREADED PIPE HANGERS. 5. PROVIDE SPRINKLER GUARDS ON ALL UPRIGHT SPRINKLER HEADS WITHIN AREA PROVIDE SPRINKLER GUARDS ON ALL UPRIGHT SPRINKLER HEADS WITHIN AREA OF RENOVATION. 6. WHERE OBSTRUCTIONS TO SPRINKLER DISCHARGE EXIST, SPRINKLERS SHALL WHERE OBSTRUCTIONS TO SPRINKLER DISCHARGE EXIST, SPRINKLERS SHALL BE LOCATED WITH RESPECT TO THE OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. REVIEW ALL AREAS IN THE SCOPE OF WORK TO ENSURE ALL OBSTRUCTIONS ARE ACCOUNTED FOR. ADD ADDITIONAL SPRINKLER HEADS WHERE REQUIRED.
AutoCAD SHX Text 9 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW BUILDING 4/5. SEE SHEET C-FX102 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW BUILDING 4/5. SEE SHEET C-FX102 FOR CONTINUATION.
AutoCAD SHX Text 10 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW PARALLELING SWITCHGEAR ROOM. SEE DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW PARALLELING SWITCHGEAR ROOM. SEE SHEET C-FX102 FOR CONTINUATION
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FX112
AutoCAD SHX Text
NEW WORK
AutoCAD SHX Text
PARTIAL FIRST FLOOR PLAN -
AutoCAD SHX Text
BUILDINGS 1 AND 6 -
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 16'
NORMAL POWER ROOM
EMERGENCY POWER ROOM
20 22 23
AA
BB
DD
B
C
M FIRE PUMP
A
JP
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
1/2" = 1'-0"C5 ENLARGED FLOOR PLAN - SPRINKLER PUMP ROOM G125W
NTSF4 FIRE PUMP ASSEMBLY RISER DIAGRAM - EXISTING
PLAN
NORTH
1/2" = 1'-0"E1 ENLARGED FLOOR PLAN - EMERGENCY AND NORMAL POWER ROOMS 101 AND 102
PLAN
NORTH
AutoCAD SHX Text
FIRE PUMP
AutoCAD SHX Text G126W
AutoCAD SHX Text G125W
AutoCAD SHX Text V1
AutoCAD SHX Text
FPS
AutoCAD SHX Text
FPD
AutoCAD SHX Text V2
AutoCAD SHX Text M1
AutoCAD SHX Text
SRC
AutoCAD SHX Text V0
AutoCAD SHX Text 6"
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 6"
AutoCAD SHX Text
FP
AutoCAD SHX Text
JP
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
EXIST. MECH'L ROOM
AutoCAD SHX Text
EXIST. MECH'L ROOM
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text X
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text N
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text 3"
AutoCAD SHX Text S2.1
AutoCAD SHX Text S2.2
AutoCAD SHX Text S2.3
AutoCAD SHX Text S2.4
AutoCAD SHX Text S2.5
AutoCAD SHX Text S2.6
AutoCAD SHX Text S2.7
AutoCAD SHX Text S2.8
AutoCAD SHX Text S2.9
AutoCAD SHX Text S2.10
AutoCAD SHX Text S2.11
AutoCAD SHX Text S2.12
AutoCAD SHX Text S2.13
AutoCAD SHX Text S2.14
AutoCAD SHX Text S2.16
AutoCAD SHX Text S2.17
AutoCAD SHX Text M2.6
AutoCAD SHX Text M2.5
AutoCAD SHX Text M2.4
AutoCAD SHX Text L2.1
AutoCAD SHX Text M2.3
AutoCAD SHX Text M2.2
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text 1 "12"
AutoCAD SHX Text L2.2
AutoCAD SHX Text L2.3
AutoCAD SHX Text L2.4
AutoCAD SHX Text L2.5
AutoCAD SHX Text L2.6
AutoCAD SHX Text L2.7
AutoCAD SHX Text L2.8
AutoCAD SHX Text L2.9
AutoCAD SHX Text L2.10
AutoCAD SHX Text L2.11
AutoCAD SHX Text L2.12
AutoCAD SHX Text L2.13
AutoCAD SHX Text L2.14
AutoCAD SHX Text L2.15
AutoCAD SHX Text L2.17
AutoCAD SHX Text L2.16
AutoCAD SHX Text S2.15
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text REMOTE AREA #C2 HAZARD: ORDINARY HAZARD GROUP 1 DEMAND AREA: 1,500 SQ FT (ACTUAL = 1,565 SQ FT) DENSITY: 0.15 GPM/SQ FT K-FACTOR: 5.6 SYSTEM DEMAND: 433.3 GPM AT 123.96 PSI AVAILABLE FLOW/PRESSURE: 433.3 GPM AT 155.00 PSI
AutoCAD SHX Text
%%UREMOTE AREA HYDRAULIC CALCULATIONS
AutoCAD SHX Text
GROUND FLOOR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
1. THIS DRAWING IS INTENDED FOR USE AS A REFERENCE ONLY. NO DEMOLITION OR NEW WORK IS THIS DRAWING IS INTENDED FOR USE AS A REFERENCE ONLY. NO DEMOLITION OR NEW WORK IS REQUIRED FOR THE EXISTING FIRE PUMP ASSEMBLY, SYSTEM PIPING, AND CONTROL PANELS.
AutoCAD SHX Text
RISER DIAGRAM NOTES
AutoCAD SHX Text
TO BUILDING 6 FIRE SPRINKLER SYSTEM
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
TO BUILDING 1 FIRE SPRINKLER SYSTEM
AutoCAD SHX Text
TO FIRE DEPARTMENT CONNECTION
AutoCAD SHX Text
EXISTING JOCKEY PUMP CONTROLLER
AutoCAD SHX Text
EXISTING FIRE PUMP CONTROLLER
AutoCAD SHX Text
EXISTING 500 GPM AT 120 PSI FIRE PUMP ON SKID
AutoCAD SHX Text
EXISTING FIRE PUMP TEST HEADER
AutoCAD SHX Text 6"
AutoCAD SHX Text
FROM CITY WATER MAIN
AutoCAD SHX Text E
AutoCAD SHX Text
EXISTING JOCKEY PUMP ON SKID
AutoCAD SHX Text
EXISTING CONCRETE PUMP SKID
AutoCAD SHX Text
EXISTING 4"X6" PIPE INCREASER WITH SIGHT GLASS
AutoCAD SHX Text V1
AutoCAD SHX Text
SRC
AutoCAD SHX Text
FPS
AutoCAD SHX Text
FPD
AutoCAD SHX Text V2
AutoCAD SHX Text M1
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text V0
AutoCAD SHX Text
1. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
AutoCAD SHX Text 1 EXISTING 6-INCH INCOMING FIRE SERVICE MAIN.EXISTING 6-INCH INCOMING FIRE SERVICE MAIN.
AutoCAD SHX Text 2 EXISTING 500 GPM FIRE PUMP AND EXISTING JOCKEY PUMP ON CONCRETE SKID.EXISTING 500 GPM FIRE PUMP AND EXISTING JOCKEY PUMP ON CONCRETE SKID.
AutoCAD SHX Text
3 EXISTING FIRE PUMP CONTROLLER.EXISTING FIRE PUMP CONTROLLER.
AutoCAD SHX Text
4 EXISTING JOCKEY PUMP CONTROLLEREXISTING JOCKEY PUMP CONTROLLER
AutoCAD SHX Text 5 EXISTING 6-INCH SUCTION AND 6-INCH DISCHARGE PIPING AND ASSOCIATED EXISTING 6-INCH SUCTION AND 6-INCH DISCHARGE PIPING AND ASSOCIATED VALVES. REFER TO FIRE PUMP RISER DIAGRAM FOR FURTHER DETAIL.
AutoCAD SHX Text
KEY NOTES
AutoCAD SHX Text
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text 6 EXISTING 4-INCH FIRE PROTECTION PIPING TO FIRE DEPARTMENT CONNECTION.EXISTING 4-INCH FIRE PROTECTION PIPING TO FIRE DEPARTMENT CONNECTION.
AutoCAD SHX Text 7 SOURCE FOR HYDRAULIC CALCULATIONS TAKEN FROM THE TEST HEADER. SOURCE FOR HYDRAULIC CALCULATIONS TAKEN FROM THE TEST HEADER. INFORMATION OF THE FIRE PUMP TEST RESULTS DATED MAY 19, 2020. STATIC PRESSURE: 45 PSI 45 PSI RESIDUAL PRESSURE: 35 PSI 35 PSI AVAILABLE FLOW: 796 GPM796 GPM
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FX401
AutoCAD SHX Text
ENLARGED PLANS
BUILDINGS 1 AND 6 -
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
NTSF8 RISER MOUNTED AIR COMPRESSOR
NTSD8 DRY SYSTEM AUXILIARY DRAIN
NTSD4 SPRINKLER HEAD DROP DETAIL
NTSB4 UPRIGHT HEAD DETAIL
NTSF4 DRY VALVE SYSTEM COMPONENTS
NTSF1 SPRINKLER HEAD PROTECTING CONDUIT
D1 ZONE CONTROL VALVE COMPONENTS
AutoCAD SHX Text
PRESSURE SWITCH
AutoCAD SHX Text
RISER MOUNTING KIT
AutoCAD SHX Text
SYSTEM RISER
AutoCAD SHX Text
AIR INTAKE FILTER(S)
AutoCAD SHX Text
GENERAL RISER MOUNTED AIR COMPRESSOR
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
RELIEF VALVE
AutoCAD SHX Text
TO VALVE AIR TRIM
AutoCAD SHX Text
CONNECT TO AIR MAINTENANCE DEVICE
AutoCAD SHX Text
1-INCH GLOBE VALVE
AutoCAD SHX Text
2 X 1 REDUCING COUPLING
AutoCAD SHX Text
2-INCH X 1-FOOT PIPE NIPPLE
AutoCAD SHX Text
2 X 1 REDUCING COUPLING
AutoCAD SHX Text
1-INCH GLOBE VALVE
AutoCAD SHX Text
1-INCH PLUG
AutoCAD SHX Text
1-INCH PIPE FROM SYSTEM
AutoCAD SHX Text
PROVIDE SUPPORT AS REQUIRED
AutoCAD SHX Text
1-INCH BLACK STEEL SCHEDULE 40 PIPING (TYP.)
AutoCAD SHX Text
NEW SPRINKLER MAIN
AutoCAD SHX Text
1 INCH PIPE REDUCING COUPLING
AutoCAD SHX Text
SUSPENDED CEILING
AutoCAD SHX Text
PROVIDE LENGTH TO SUIT
AutoCAD SHX Text
PROVIDE NEW (QR) FM/UL SEMI-RECESSED PENDENT HEAD, CENTER OF TILE
AutoCAD SHX Text NOTES: 1. ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH AS CEILING "T" BAR SUSPENSION SYSTEM. LIGHT FIXTURES, ETC. PROVIDE A PIPE HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24" 2. ALL NEW PENDENT HEADS SHALL BE FM APPROVED, SEMI-RECESSED, ALL NEW PENDENT HEADS SHALL BE FM APPROVED, SEMI-RECESSED, QUICK RESPONSE TYPE. 3. ALL NEW HEADS SHALL BE CENTER OF TILE.ALL NEW HEADS SHALL BE CENTER OF TILE.
AutoCAD SHX Text 12"
AutoCAD SHX Text
NON COMBUSTIBLE METAL ROOF DECKING
AutoCAD SHX Text
BRANCHLINE WITH SIZE AS SHOWN ON PLAN
AutoCAD SHX Text
1-INCH SPRIG UP
AutoCAD SHX Text
DEFLECTOR DISTANCES TO CONFORM WITH REQUIREMENTS OF NFPA 13 SECTION 10.2.7.2.
AutoCAD SHX Text
UPRIGHT HEAD WITH GUARD
AutoCAD SHX Text
STRUCTURAL WEB JOIST/ BEAM WITH WRAPPED FIREPROOFING
AutoCAD SHX Text
AS NOTED ON SITE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
PIPE DISCHARGE TO FLOOR DRAIN
AutoCAD SHX Text
PROVIDE SUPPORT AS REQUIRED
AutoCAD SHX Text
DRAIN CUP
AutoCAD SHX Text
FROM SPRINKLER MAIN
AutoCAD SHX Text
INDICATING BUTTERFLY VALVE WITH SUPERVISORY SWITCH
AutoCAD SHX Text
ALARM PRESSURE SWITCH
AutoCAD SHX Text
ACCELERATOR
AutoCAD SHX Text
AIR PRESSURE SUPERVISORY SWITCH
AutoCAD SHX Text
AIR PRESSURE MAINTENANCE DEVICE
AutoCAD SHX Text
PRESSURE GAUGE
AutoCAD SHX Text
TO SPRINKLERS
AutoCAD SHX Text
AIR COMPRESSOR
AutoCAD SHX Text
DRY VALVE
AutoCAD SHX Text
LINES OF ELECTRICAL CONDUITS BEYOND. SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
3-INCH MAIN LINE RUNNING PARALLEL TO CONDUIT
AutoCAD SHX Text
UPRIGHT SPRINKLER HEAD WITH CAGE OVER CONDUIT
AutoCAD SHX Text
BUTTERFLY VALVE WITH TAMPER SWITCH
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
TO SPRINKLER SYSTEM
AutoCAD SHX Text
TEST & DRAIN ASSEMBLY
AutoCAD SHX Text
PIPING TO DRAIN
AutoCAD SHX Text
PRESSURE RELIEF VALVE
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FX501
AutoCAD SHX Text
FIRE SUPPRESSION
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
BLDG 6
MAIN ENTRANCE
Q
R
T
R
S
Q
N
L
11 12
13 15
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
PARTIAL FIRST FLOOR PLAN
D3
PLAN
NORTH
AutoCAD SHX Text
ELEC 1052C-EL
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
DUCT SHAFT
AutoCAD SHX Text
MEN'S TOILET
AutoCAD SHX Text
STAFF FEM.
AutoCAD SHX Text
MAIN LOBBY
AutoCAD SHX Text 1003W
AutoCAD SHX Text
ENTRY
AutoCAD SHX Text 1004W
AutoCAD SHX Text 133.14
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1058S
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1059S
AutoCAD SHX Text
COMMNUNICATION
AutoCAD SHX Text 1060S
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text
1060AS
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1057S
AutoCAD SHX Text
PLANTER
AutoCAD SHX Text
ELIGIBILITY INTERVIEW #1
AutoCAD SHX Text 1501A
AutoCAD SHX Text
ELECTRIC RM
AutoCAD SHX Text
1052C-EL
AutoCAD SHX Text
ELECTRIC RM
AutoCAD SHX Text
1003W-EL
AutoCAD SHX Text
DRESSING ROOM
AutoCAD SHX Text 1067S
AutoCAD SHX Text
FIRE PANEL ROOM
AutoCAD SHX Text 1000W
AutoCAD SHX Text 1001C
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-FA111
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text
FACP
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.' REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.' 2. THERE IS NO NEW WORK ON THIS SHEET. SHEET PROVIDED FOR REFERENCE ONLY.THERE IS NO NEW WORK ON THIS SHEET. SHEET PROVIDED FOR REFERENCE ONLY.
AutoCAD SHX Text 1 LOCATION OF EXISTING FIRE ALARM PANELS AND EQUIPMENT SHOWN FOR REFERENCE ONLY. LOCATION OF EXISTING FIRE ALARM PANELS AND EQUIPMENT SHOWN FOR REFERENCE ONLY. 2 EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING CONSTRUCTION. MAINTAIN FIRE ALARM CIRCUIT INTEGRITY OF EXISTING FIRE ALARM CIRCUIT.
AutoCAD SHX Text
%%UKEYNOTES
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FA110
AutoCAD SHX Text
NEW WORK
AutoCAD SHX Text
PARTIAL FIRST FLOOR PLAN -
AutoCAD SHX Text
BUILDINGS 1 AND 6 -
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
Z.8
AA.2
NORMAL POWER ROOM
1115AC-EL
EMERGENCY POWER ROOM
ELEC
1056S-EL
ELEC
1064S-EL
ELEC
DD.5
20.5
22.8 22.9
22.8 22.9
18.2 20.5 22.8
18.1
22.9
22.8
18.1 22.9
18.4
DD.8
BB.5
AA.5AA.5
EE
BB
AA
22 23
DD
HH
10 11
W
X
Z
4 5 7 92 31
EX
EX
EX
EX
EX
EX
EX
DD
EX
X
V
W
U
Y
Z
AA
BB
DD
EE
11 12
13 15
9754321
18 20 22 23
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
PARTIAL FIRST FLOOR PLAN
F1
PLAN
NORTH
AutoCAD SHX Text
ELEC 1056S-EL
AutoCAD SHX Text
ELEC 1115AC-EL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
STAIRS #3
AutoCAD SHX Text 1071S
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
SERVICE ELEV.
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
DUCT SHAFT
AutoCAD SHX Text
EL. CAB.
AutoCAD SHX Text 1073S
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text 1078S
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text 1077S
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text 1076S
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1075S
AutoCAD SHX Text
CHIEF OF VOLUNTEER
AutoCAD SHX Text 1074S
AutoCAD SHX Text
LOUNGE
AutoCAD SHX Text 1072S
AutoCAD SHX Text
BOARD OF ED.
AutoCAD SHX Text 1071S
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1070S
AutoCAD SHX Text
INTERVIEW
AutoCAD SHX Text 1080S
AutoCAD SHX Text
P16 ELEV
AutoCAD SHX Text
CONTROL
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text 1082S
AutoCAD SHX Text
W. TOILET
AutoCAD SHX Text 1083S
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text 1085S
AutoCAD SHX Text
WAITING
AutoCAD SHX Text 1079S
AutoCAD SHX Text
VACANT
AutoCAD SHX Text
1089AS
AutoCAD SHX Text
EL. CAB.
AutoCAD SHX Text 1073A-S
AutoCAD SHX Text
SECONDARY MANIFOLD RM
AutoCAD SHX Text 1091S
AutoCAD SHX Text
PATIENT FUNDS
AutoCAD SHX Text 1114C
AutoCAD SHX Text
MEN'S TOILET
AutoCAD SHX Text 1052C
AutoCAD SHX Text
STAFF FEM.
AutoCAD SHX Text 1038C
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 1095S
AutoCAD SHX Text
MED / AIR RM
AutoCAD SHX Text 1092S
AutoCAD SHX Text
BARBER SHOP
AutoCAD SHX Text 1090S
AutoCAD SHX Text
FA ATS
AutoCAD SHX Text 1093S
AutoCAD SHX Text
RETAIL STORE AREA
AutoCAD SHX Text 1064S
AutoCAD SHX Text
ELEC. CLOS.
AutoCAD SHX Text 1087S
AutoCAD SHX Text
QA OFFICE
AutoCAD SHX Text 1086S
AutoCAD SHX Text
SVC. ORGANIZATION
AutoCAD SHX Text 1089S
AutoCAD SHX Text
SECRETARY
AutoCAD SHX Text
1060AS
AutoCAD SHX Text
RECEPTION
AutoCAD SHX Text
1053AS
AutoCAD SHX Text 1057S
AutoCAD SHX Text
TRAINING RM.
AutoCAD SHX Text 1056S
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text 1055S
AutoCAD SHX Text
MEN'S LOCKER
AutoCAD SHX Text 1054S
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 1053S
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text 1095C
AutoCAD SHX Text
CONSULTATION
AutoCAD SHX Text
1125BN
AutoCAD SHX Text
CONSULTATION
AutoCAD SHX Text
1125AN
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text
1124AN
AutoCAD SHX Text
OUTPATIENT PHARM. SUPR.
AutoCAD SHX Text 1122N
AutoCAD SHX Text
AGENT CASHIER
AutoCAD SHX Text 1161N
AutoCAD SHX Text
SUPPORT SVC.
AutoCAD SHX Text 1093C
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text 1097C
AutoCAD SHX Text
POLICE OFFICE
AutoCAD SHX Text
1106AC
AutoCAD SHX Text
SUB CORRIDOR
AutoCAD SHX Text 1101C
AutoCAD SHX Text
MEDICAL DATA
AutoCAD SHX Text 1107C
AutoCAD SHX Text
SUPPORT SERV.
AutoCAD SHX Text
1110CC
AutoCAD SHX Text
MAS. SUP.
AutoCAD SHX Text
1110BC
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
1115BC
AutoCAD SHX Text
PHARM. OFFICE
AutoCAD SHX Text
1121BN
AutoCAD SHX Text
GAS METERS
AutoCAD SHX Text
1107AC
AutoCAD SHX Text
POLICE OFFICE
AutoCAD SHX Text 1106C
AutoCAD SHX Text
POLICE OFFICE
AutoCAD SHX Text
1106BC
AutoCAD SHX Text
UP
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
UP
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text 1107 E
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-1
AutoCAD SHX Text
MEDICAL ADMINISTRATION RECORDS
AutoCAD SHX Text 1101C
AutoCAD SHX Text
MATERIAL DIST. ROOM
AutoCAD SHX Text
1101AC
AutoCAD SHX Text
MECHANICAL RM.
AutoCAD SHX Text
1099AC
AutoCAD SHX Text
VACANT
AutoCAD SHX Text
1110AC
AutoCAD SHX Text
LOCKER RM.
AutoCAD SHX Text
1117AC
AutoCAD SHX Text
LOCKER RM.
AutoCAD SHX Text
1117BC
AutoCAD SHX Text
CHIEF HEALTH INFO.
AutoCAD SHX Text
1117CC
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text 1111C
AutoCAD SHX Text
MALE TOILET
AutoCAD SHX Text
1113AC
AutoCAD SHX Text
FEMALE LOCKERS
AutoCAD SHX Text
1119AC
AutoCAD SHX Text
MALE LOCKERS
AutoCAD SHX Text 1113C
AutoCAD SHX Text
EXIST. MECH'L ROOM
AutoCAD SHX Text
EXIST. MECH'L ROOM
AutoCAD SHX Text
EXIST. CORRIDOR
AutoCAD SHX Text
EXIST. CORRIDOR
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text
RD
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
ELECTRIC RM
AutoCAD SHX Text
1107C-EL
AutoCAD SHX Text
MEDICAL INFORMATION
AutoCAD SHX Text
1115AC
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
AutoCAD SHX Text
WAITING
AutoCAD SHX Text
1115CC
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
1115DC
AutoCAD SHX Text
SERVICE ELEV.
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE ELEV.
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE ELEV.
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
SERVICE ELEV.
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
ELEV. SHAFT
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-FA112
AutoCAD SHX Text N
AutoCAD SHX Text 110cd
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text 15cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text 75cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text 75cd
AutoCAD SHX Text N
AutoCAD SHX Text 75cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-FA110
AutoCAD SHX Text P
AutoCAD SHX Text 15cd
AutoCAD SHX Text 15cd
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text 75cd
AutoCAD SHX Text 30cd
AutoCAD SHX Text 75cd
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text
RIL-TS
AutoCAD SHX Text
RM
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text N
AutoCAD SHX Text
NAC
AutoCAD SHX Text E
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text 60cd
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
AutoCAD SHX Text 1 EXISTING MONITOR MODULES FOR SPRINKLER SYSTEM SUPERVISION SHOWN FOR REFERENCE ONLY. EXISTING MONITOR MODULES FOR SPRINKLER SYSTEM SUPERVISION SHOWN FOR REFERENCE ONLY. 2 PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO NEW NAC AND SPEAKER CIRCUIT IN PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO NEW NAC AND SPEAKER CIRCUIT IN NEW PANELS. SEE KEYNOTE 10. 3 PROVIDE NEW STROBE. CONNECT TO CLOSEST NAC WITH SUFFICIENT SPARE POWER SUPPLY CAPACITY. PROVIDE NEW STROBE. CONNECT TO CLOSEST NAC WITH SUFFICIENT SPARE POWER SUPPLY CAPACITY. 4 EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING CONSTRUCTION. MAINTAIN FIRE ALARM CIRCUIT INTEGRITY OF EXISTING FIRE ALARM CIRCUIT. 5 REINSTALL STROBE. CONNECT TO SAME NAC AS REMOVED FROM PRIOR TO DEMOLITION. REINSTALL STROBE. CONNECT TO SAME NAC AS REMOVED FROM PRIOR TO DEMOLITION. 6 PROVIDE NEW MONITOR MODULES FOR NEW ZONE CONTROL VALVE. CONNECT ACCESSIBLE DEVICES TO PROVIDE NEW MONITOR MODULES FOR NEW ZONE CONTROL VALVE. CONNECT ACCESSIBLE DEVICES TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. 7 DUCT DETECTOR PROVIDED ON SUPPLY DUCTWORK FOR RTU-2. CONNECT ADDRESSABLE DEVICE TO DUCT DETECTOR PROVIDED ON SUPPLY DUCTWORK FOR RTU-2. CONNECT ADDRESSABLE DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. COORDINATE AUTOMATIC CONTROL REQUIREMENTS WITH THE MECHANICAL SYSTEM. REFER TO MECHANICAL DRAWINGS FOR FURTHER DETAILS. 8 PROVIDE NEW RELAY MODULE IN CEILING FOR RTU-2 FAN SHUTDOWN AND BMS SIGNAL ON ROOF. MODULE PROVIDE NEW RELAY MODULE IN CEILING FOR RTU-2 FAN SHUTDOWN AND BMS SIGNAL ON ROOF. MODULE SIGNALS SHALL INTERFACE WITH BUILDING CONTROLS. REFER TO MECHANICAL DRAWINGS FOR FURTHER DETAIL. 9 PROVIDE REMOTE INDICATING LAMP AND TEST KEY SWITCH ON WALL. DEVICE SHALL BE LOCATED 7 FEET PROVIDE REMOTE INDICATING LAMP AND TEST KEY SWITCH ON WALL. DEVICE SHALL BE LOCATED 7 FEET ABOVE FINISHED FLOOR TO FACILITATE TESTING OF DUCT SMOKE DETECTOR. 10 PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO ELECTRICAL ROOM FIRE ALARM SYSTEM PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO ELECTRICAL ROOM FIRE ALARM SYSTEM DEVICES. CONNECT FATC TO MAIN HOSPITAL FACP. PROVIDE BATTERY BACKUP FOR SPEAKER/STROBE CIRCUITS PER NFPA 72 WITH ENOUGH CAPACITY REQUIRED BY SPECIFICATION 28 31 00. 11 PROVIDE NEW MANUAL PULL STATION. CONNECT TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. PROVIDE NEW MANUAL PULL STATION. CONNECT TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. 12 ADD MONITOR MODULE TO MONITOR EXISTING ISOLATION VALVE. CONNECT DEVICE TO CLOSEST SLC. VERIFY ADD MONITOR MODULE TO MONITOR EXISTING ISOLATION VALVE. CONNECT DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS.
AutoCAD SHX Text
%%UKEYNOTES
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FA111
AutoCAD SHX Text
NEW WORK
AutoCAD SHX Text
PARTIAL FIRST FLOOR PLAN -
AutoCAD SHX Text
BUILDINGS 1 AND 6 -
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
GENSET #2
GEN-2
GENSET #3
GEN-3
PARALLELING SWITCHGEAR ROOM
PSR-1
BLDG. #5 MAIN ELECTRIC ROOM
MER-5
20.5
22.8 22.9
20.5
22.8
18.1 22.9
DD.8
DD.8
EE
20 22 23
302826
EX
EX
EX
EX
EX EX
EX
EX.
EE
EX
13 15
18 20 22 23 24 26
28 30
PARTIAL FIRST FLOOR PLAN - GENERATOR PLATFORM
F4
PLAN
NORTH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
AutoCAD SHX Text
GENERATORS
AutoCAD SHX Text
MASTER
AutoCAD SHX Text
CONTROLS
AutoCAD SHX Text
(GMC)
AutoCAD SHX Text
GEN 1
AutoCAD SHX Text
GEN 2
AutoCAD SHX Text
GEN 3
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
FB
AutoCAD SHX Text
SPACE FOR PANELS
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
DN
AutoCAD SHX Text
SPACE
AutoCAD SHX Text
FOR BATTERY RACK
AutoCAD SHX Text
DN
AutoCAD SHX Text D
AutoCAD SHX Text C.1
AutoCAD SHX Text C
AutoCAD SHX Text B.4
AutoCAD SHX Text B
AutoCAD SHX Text A.8
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2.8
AutoCAD SHX Text
AutoCAD SHX Text 3.8
AutoCAD SHX Text
AutoCAD SHX Text 3.5
AutoCAD SHX Text
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-FA111
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text 30cd
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
N,WP
AutoCAD SHX Text 75cd
AutoCAD SHX Text N
AutoCAD SHX Text 75cd
AutoCAD SHX Text N
AutoCAD SHX Text 75cd
AutoCAD SHX Text
FATC
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
MM
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EXIST. MECH'L ROOM
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text
CHILLER
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
CHILLER PLANT ENGINEER OFFICE
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
ENGINEER OFFICE
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text
MM
AutoCAD SHX Text E
AutoCAD SHX Text
AutoCAD SHX Text
1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.
AutoCAD SHX Text 1 EXISTING MONITOR MODULES FOR SUPERVISION OF EXISTING DRY PIPE VALVE ASSEMBLY SERVING EXISTING MONITOR MODULES FOR SUPERVISION OF EXISTING DRY PIPE VALVE ASSEMBLY SERVING TRANSFORMER VAULT WITHIN BUIKLDING 5. REFER TO FIRE PROTECTION DRAWINGS FOR FURTHER DETAIL. 2 EXISTING SPARE MONITOR MODULES SHOWN FOR REFERENCE ONLY. EXISTING SPARE MONITOR MODULES SHOWN FOR REFERENCE ONLY. 3 NEW MONITOR MODULES FOR SUPERVISION OF NEW DRY PIPE VALVE AND MONITORING ABNORMAL NEW MONITOR MODULES FOR SUPERVISION OF NEW DRY PIPE VALVE AND MONITORING ABNORMAL AIR PRESSURE SERVING SWITCHGEAR VAULT ON GENERATOR PLATFORM AND BELOW BUILDINGS 4/5. CONNECT DEVICES TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. REFER TO FIRE PROTECTION DRAWINGS FOR FURTHER DETAIL. 4 TEMPORARY MANUAL PULL STATION SERVING INTERIM EXIT STAIRWAY. CONNECT ADDRESSABLE TEMPORARY MANUAL PULL STATION SERVING INTERIM EXIT STAIRWAY. CONNECT ADDRESSABLE DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. MANUAL PULL STATION TO BE REMOVED WHEN INTERIM EXIT STAIRWAY IS NO LONGER IN SERVICE AND REMOVED. 5 PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO GENERATOR PLATFORM FIRE ALARM PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO GENERATOR PLATFORM FIRE ALARM SYSTEM DEVICES. CONNECT FATC TO MAIN HOSPITAL FACP. PROVIDE BATTERY BACKUP FOR SPEAKER/STROBE CIRCUITS PER NFPA 72 WITH ENOUGH CAPACITY REQUIRED BY SPECIFICATION 28 31 00. 6 PROVIDE NEW HEAT DETECTOR OF FIXED TEMPERATURE TYPE WITH EXTRA HIGH TEMPERATURE PROVIDE NEW HEAT DETECTOR OF FIXED TEMPERATURE TYPE WITH EXTRA HIGH TEMPERATURE (325 DEG. F) RATING AS ALLOWED IN VA DESIGN MANUAL SECTION 7.4.E. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PLATFORM SLC. 7 PROVIDE NEW WEATHERPROOF SPEAKER/STROBE COMBINATION DEVICE UNDER CANOPY. CONNECT PROVIDE NEW WEATHERPROOF SPEAKER/STROBE COMBINATION DEVICE UNDER CANOPY. CONNECT TO GENERATOR PLATFORM NAC AND SPEAKER CIRCUITS. 8 PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO GENERATOR PLATFORM NAC PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO GENERATOR PLATFORM NAC AND SPEAKER CIRCUITS. 9 PROVIDE NEW MANUAL PULL STATION. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PROVIDE NEW MANUAL PULL STATION. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PLATFORM SLC.
AutoCAD SHX Text
%%UKEYNOTES
AutoCAD SHX Text
%%UGENERAL NOTES
AutoCAD SHX Text
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FA112
AutoCAD SHX Text
NEW WORK
AutoCAD SHX Text
PARTIAL FIRST FLOOR PLAN -
AutoCAD SHX Text
BUILDINGS 1 AND 6 -
AutoCAD SHX Text
SCALE: 1/8" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 4'
AutoCAD SHX Text
AutoCAD SHX Text 16'
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
BLDG 6
ADDRESSABLE SMOKE
DETECTOR DEVICE
CEILING OR
DECKING
STANDARD JUNCTION BOX
(RECESSED)
CEILING OR
DECKING
STANDARD JUNCTION BOX
(SURFACE MOUNTED)
ADDRESSABLE SMOKE
DETECTOR DEVICE
STANDARD MOUNTING
BOX
MANUAL PULL STATION
BACKPLATE
LOCKING SCREW
MANUAL PULL STATION
HOUSING
PUSH
WIRE IN CONDUIT
STANDARD JUNCTION BOX
(RECESSED)
SEE ARCH. PLANS WALL OR
STRUCTURE SCHEDULE
WALL MOUNTED STROBE OR
SPEAKER/STROBE
FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX
SYSTEM INPUTS SYSTEM OUTPUTS
X X X X X
X X X X X
X X X X X
X X X X X
X X X X X
X
X
X
X
X
WATERFLOW SWITCH
OS&Y VALVE WITH
TAMPER SWITCH
NOTE:
ADJUST WATERFLOW DEVICE (VANE TYPE)
TO SEND SIGNAL WITHIN 45 SECONDS OF
OPENING INSPECTOR TEST CONNECTION.
FIRE ALARM
WIRE/CONDUIT
WATERTIGHT
JUNCTION BOX
WATERTIGHT FIRE
ALARM CONDUIT
WATERTIGHT
JUNCTION BOX
WATERTIGHT FIRE
ALARM CONDUIT
SWITCHPLATE (BLANK)
INTELLIGENT
INTERFACE MODULE
4-INCH SQUARE X 3
1/2-INCH DEEP
ELECTRICAL JUNCTION
BOX
NOTE:
MOUNT INTELLIGENT INTERFACE MODULE
CLOSE TO ITS ASSOCIATED MONITORING
DEVICE OR CONTROL DEVICE (I.E. FIRE
SPRINKLER FLOW SWITCH, HVAC SHUTDOWN
AND DOOR HOLDER OPERATION) AT AN
ACCESSIBLE LOCATION
DUCTWORK
DUCT SMOKE DETECTOR
SAMPLING TUBE
REMOTE LIGHT/
SWITCH FOR DUCT
MOUNTED SMOKE
DETECTOR
NOTE:
1. MOUNT DETECTOR IN ACCORDANCE WITH
MANUFACTURERS RECOMMENDATIONS.
2. COORDINATE EXACT MOUNTING LOCATIONS OF THE
DUCT DETECTOR IN FIELD.
3. PROVIDE ALL INTELLIGENT DUCT SMOKE DETECTORS
WITH AN APPROPRIATELY SIZED DUCT SAMPLING TUBE.
ADDRESSABLE DUCT
MOUNTED SMOKE
DETECTOR
FIRE ALARM
WIRE/CONDUIT
TYPICAL JUNCTION BOX
TO OTHER FIRE ALARM DEVICES
DUCT SMOKE DETECTOR
EXHAUST TUBE
TYPICAL SURFACE MOUNTED SMOKE DETECTOR
NTS
B5
TYPICAL CEILING MOUNTED SMOKE DETECTOR
TYPICAL MANUAL PULL STATION
NTS
D5
TYPICAL WALL MOUNTED SPEAKER/STROBE
NTS
D7
FIRE ALARM OPERATION MATRIX
NTS
D1
TYPICAL DUCT DETECTOR DETAIL
NTS
F8
TYPICAL INTELLIGENT INTERFACE MODULE
NTS
F5
TYPICAL WET PIPE MOUNTED DETAIL
F3
B3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text
SOUND GENERAL BUILDING ALARM FOR OTHER AND HIGH RISE (NON-HEALTH CARE)
AutoCAD SHX Text NOTIFY NECESSARY STAFF FOR HEALTH CARE AND HIGH RISE BUILDINGS ONLY (ALARM SIGNAL MAY BE DIFFERENT ON DIFFERENT FLOORS)
AutoCAD SHX Text
NOTIFY THE FIRE DEPARTMENT
AutoCAD SHX Text
INITIATE SUPERVISORY SIGNAL TO A 24-HOUR MANNED POINT FOR IMMEDIATE RESPONSE
AutoCAD SHX Text
INITIATE TROUBLE SIGNAL
AutoCAD SHX Text
CLOSE ASSOCIATE SMOKE BARRIER DOORS ON THE FLOOR
AutoCAD SHX Text
CLOSE DAMPERS ON FAN PROXIMATE TO DETECTOR
AutoCAD SHX Text
SHUT DOWN AIR HANDLING UNIT SERVED BY THE DETECTOR
AutoCAD SHX Text
SIGNAL BUILDING MANAGEMENT SYSTEM OF SHUTDOWN EVENT
AutoCAD SHX Text
OPEN LOCKED EGRESS DOORS ON FLOOR OF FIRE ORIGIN
AutoCAD SHX Text
RECALL ELEVATORS TO PRIMARY FLOOR
AutoCAD SHX Text
RECALL ELEVATORS TO SECONDARY FLOOR
AutoCAD SHX Text
DUCT SMOKE DETECTOR
AutoCAD SHX Text
AREA SMOKE DETECTOR
AutoCAD SHX Text
MANUAL PULL STATION
AutoCAD SHX Text
GENERATOR ENCLOSURE HEAT DETECTOR
AutoCAD SHX Text
SPRINKLER WATERFLOW SWITCH
AutoCAD SHX Text
SPRINKLER AND STANDPIPE VALVE TAMPER SWITCH
AutoCAD SHX Text
DRY SPRINKLER HIGH/LOW PRESSURE SWITCH
AutoCAD SHX Text
ELEVATOR RECALL LOBBY SMOKE DETECTOR - PRIMARY FLOOR
AutoCAD SHX Text
ELEVATOR RECALL LOBBY SMOKE DETECTOR - ALTERNATE FLOOR
AutoCAD SHX Text
DRY PIPE SPRINKLER ZONE PRESSURE SWITCH
AutoCAD SHX Text
1. ACTIVATION OF ANY ALARM OR SUPERVISORY INITIATING DEVICE SHALL ACTIVATION OF ANY ALARM OR SUPERVISORY INITIATING DEVICE SHALL INITIATE FUNCTIONS CONSISTENT WITH THE EXISTING FIRE ALARM SYSTEM PROGRAMING. ALARM SIGNALS IN INDIVIDUAL SMOKE COMPARTMENTS SHALL BE COORDINATED WITH THE FIRE/SMOKE BARRIERS AND SPRINKLER ZONES.
AutoCAD SHX Text
FIRE ALARM MATRIX NOTES:
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NTS
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
AutoCAD SHX Text
SH
AutoCAD SHX Text
AD
AutoCAD SHX Text
AutoCAD SHX Text
C-FA601
AutoCAD SHX Text
AND OPERATION MATRIX
FIRE ALARM DETAILS
FIRE ALARM RISER DIAGRAM
NTS
F1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh
1 & GEN PLTFRM
Key Plan
Balance of Work
9/12/2022
AutoCAD SHX Text
1. THE FIRE ALARM RISER DIAGRAM ABOVE IS DIAGRAMMATIC AND NOT ALL THE FIRE ALARM RISER DIAGRAM ABOVE IS DIAGRAMMATIC AND NOT ALL COMPONENTS OF THE FIRE ALARM SYSTEM ARE PROVIDED. CONTRACTOR SHALL SUBMIT RISER DIAGRAM WITH ALL NEW DEVICES FROM FLOOR PLANS CONNECTED TO CIRCUITS SHOWN FOR APPROVAL. 2. CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED TO CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED TO MAKE THE SYSTEM COMPLETE. 3. NOT ALL EXISTING FIRE ALARM DEVICES AND EQUIPMENT ARE SHOWN. NOT ALL EXISTING FIRE ALARM DEVICES AND EQUIPMENT ARE SHOWN. CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO ANY DEMOLITION OR NEW INSTALLATION WORK ON THE SITE FIRE ALARM SYSTEM. 4. THE EXISTING FIRE ALARM MANUFACTURER IS HONEYWELL-NOTIFIER. THE EXISTING FIRE ALARM MANUFACTURER IS HONEYWELL-NOTIFIER. 5. NEW FIRE ALARM DEVICES INSTALLED IN THE EXISTING BUILDING 1 AND NEW FIRE ALARM DEVICES INSTALLED IN THE EXISTING BUILDING 1 AND BUILDING 6 SHALL BE CONNECTED TO THE EXISTING FIRE ALARM SYSTEM AND TAPPED OFF THE NEAREST EXISTING CIRCUIT WITH SUFFICIENT CAPACITY. 6. COORDINATE DOOR HOLDER INSTALLATION WITH DOOR HARDWARE COORDINATE DOOR HOLDER INSTALLATION WITH DOOR HARDWARE CONTRACTOR, SPECIFICATION SECTION 08 71 00. 7. CLASS AND STYLE OF THE NEW/EXTENDED CIRCUITS SHALL BE SAME AS CLASS AND STYLE OF THE NEW/EXTENDED CIRCUITS SHALL BE SAME AS EXISTING FIRE ALARM CIRCUITS. WIRING FOR THE FIRE ALARM FOR THE BUILDING SHALL BE AS FOLLOWS: SIGNALING LINE CIRCUITS - CLASS B NOTIFICATION APPLIANCE CIRCUITS - CLASS B SPEAKER CIRCUITS - CLASS B COMMUNICATIONS BETWEEN FIRE ALARM CONTROL PANELS - CLASS X 8. THE FIRE ALARM RISER DIAGRAM ABOVE DOES NOT INCLUDE FIRE ALARM THE FIRE ALARM RISER DIAGRAM ABOVE DOES NOT INCLUDE FIRE ALARM SYSTEM INFORMATION FOR LEVEL 2 AND THE ABOVE FLOORS OF THE FACILITY. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF SYSTEM COMPONENTS SUCH THAT WORK ON LEVEL 1 AND THE GROUND LEVEL DO NOT INTERRUPT FIRE ALARM SYSTEM OPERATIONS ON THE REMAINING FLOORS OF THE FACILITY. 9. FIRE ALARM SPEAKERS SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE FIRE ALARM SPEAKERS SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE ALARM SPEAKER CIRCUITS. 10. FIRE ALARM STROBES SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE ALARM STROBES SHALL BE ALTERNATELY WIRED BETWEEN TWO NOTIFICATION APPLIANCE CIRCUITS. 11. THE FIRE ALARM RISER DIAGRAM ABOVE SHOWS GENERAL INFORMATION THE FIRE ALARM RISER DIAGRAM ABOVE SHOWS GENERAL INFORMATION ON THE QUANTITY AND AREA WHERE FIRE ALARM DEVICES AND EQUIPMENT ARE LOCATED. REFER TO FLOOR PLANS FOR EXACT LOCATION OF FIRE ALARM DEVICES. 12. REFER TO FLOOR PLANS FOR CANDELA RATINGS OF FIRE ALARM STROBE REFER TO FLOOR PLANS FOR CANDELA RATINGS OF FIRE ALARM STROBE DEVICES. 13. ALL NEW FIRE ALARM ZONES AND ALARMS SHALL BE SIGNALED ON ALL NEW FIRE ALARM ZONES AND ALARMS SHALL BE SIGNALED ON EXISTING FIRE ALARM PANELS AND ANNUNCIATORS. 14. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY MODULES, CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY MODULES, COMPONENTS, MODIFICATIONS, AND PROGRAMMING AS REQUIRED TO INTERFACE THE NEW FIRE ALARM DEVICES AND EQUIPMENT TO THE EXISTING SYSTEM. 15. DO NOT RUN FIRE ALARM CABLES IN THE SAME RACEWAY AS NON-FIRE DO NOT RUN FIRE ALARM CABLES IN THE SAME RACEWAY AS NON-FIRE ALARM CABLES.
AutoCAD SHX Text
RISER DIAGRAM NOTES:
AutoCAD SHX Text
FIRST FLOOR
AutoCAD SHX Text
GROUND FLOOR
AutoCAD SHX Text
MAIN
AutoCAD SHX Text
FACP
AutoCAD SHX Text
120 VAC
AutoCAD SHX Text
FA
AutoCAD SHX Text
WKSTN
AutoCAD SHX Text
PRN
AutoCAD SHX Text
FA
AutoCAD SHX Text P
AutoCAD SHX Text
MM
AutoCAD SHX Text
BUILDING 1 SPACES
AutoCAD SHX Text
FATC
AutoCAD SHX Text P
AutoCAD SHX Text
GENERATOR PLATFORM
AutoCAD SHX Text
FIRE COMMAND CENTER
AutoCAD SHX Text
FATC
AutoCAD SHX Text P
AutoCAD SHX Text
MM
AutoCAD SHX Text
BUILDING 6 SPACES
AutoCAD SHX Text
MM
AutoCAD SHX Text
FATC
AutoCAD SHX Text
120 VAC
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
FATC
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text
FA
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
SPKC
AutoCAD SHX Text
NAC
AutoCAD SHX Text
SPKC
AutoCAD SHX Text
NA…
This is the start of the file's text. The full file is on GovTribe.