B-Architecture-Part 4.pdf
PDF 6 MB Posted
- Solicitation number
- QSE--36C10F24R50018
About this file
This document appears to be architectural drawings and details related to a federal contract opportunity for the Manhattan VA Medical Center campus. The key details are:
The solicitation is for the Balance of Work construction at the VA NY Healthcare System's Manhattan campus, as part of the Manhattan Hurricane Sandy Recovery Program. The project involves constructing various interior and exterior elements, including doors, frames, partitions, and mechanical systems. The drawings provide details on door and frame types, partition wall construction, mechanical duct penetrations, and other technical specifications. This appears to be part of the Construction Document phase of the project. No specific pricing, set asides, award dates, or other contracting details are provided in this document. The drawings would be used by prospective offerors to understand the technical requirements of this construction project.
View the file
Other files
Show 40 more
Latest 50 of 281 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
100 SQ. IN. MAX
4" X 25" @
RATED DOORS
TA OR FIRE
RESISTANT
AS SCHEDULED
3'- 6"
9"
WM
THIN SET TILE **
GROUT
STANDARD HM
FRAME
ADJUSTABLE
ANCHORS
NO
M
CM
U
1/2
3/4
1/4
CAULK ALL
AROUND
GROUT
STANDARD HM
FRAME
ADJUSTABLE
ANCHORS
NO
M
CM
U
1/2
1/2
FRAMES IN MASONRY PARTITION
*** FRAME WIDTH FOR NOMINAL MASONRY
6 3/4" w/ 6" CMU
MASONRY BLOCK WITH
CERAMIC TILE FINISH
** COORDINATE TILE / SIDE & FINISH WITH
FINISH SCHEDULE
GROUT CELL SOLID
AT ANCHORS
JAMB JAMB
GROUT CELL SOLID AT
ANCHORS
ALIGN SETTING BED
CAULK ALL AROUND
CERAMIC TILE **
1. ALL DOORS SHALL BE FLUSH - 1 3/4" (44mm) THICK UNLESS
NOTED OTHERWISE.
2. EVEN NUMBERS ARE METAL; ODD NUMBERS ARE WOOD.
3. MAXIMUM 1/2" UNDERCUT AT FIRE RATED DOORS. VERIFY
EXISTING SLAB CONDITION.
4. FOR DOOR PERFORMANCE LEVEL REQUIREMENTS, SEE
SPECIFICATION 08 11 13.
5. VERIFY ALL DIMENSIONS BASED UPON FIELD CONDITIONS PRIOR
TO FABRICATIONS OR INSTALLATION. TYPICAL OF ALL OPENINGS.
GENERAL DOOR NOTES:
HM FRAME
16" 115 16"
2" 5/8
4 1/2" (V.I.F.)
EXISTING MASONRY
WALL WITH PLASTER
FINISHED (V.I.F.)
REPAIR ALL DAMAGE
PLASTER AS REQUIRED
TO MATCH AND ALIGN
WITH ADJACENT SURFACE
REPAIR DAMAGED AREAS
AND FILL VOID
WITH CEMENT GROUT
SEALANT / FIRE STOP
ASSEMBLY AT RATED
WALL
(TYPICAL BOTH SIDES)
1/4" 1/4"
PAINT ENTIRE EXPOSED
WALL SURFACES TO
MATCH EXISTING
L4"x3"x1
4" WITH 6" BEARING
ON BOTH SIDES
SAWCUT EXISTING
MASONRY
WALL AS REQUIRED TO
RECEIVE NEW OPENING
FILL VOID SOLID
WITH CEMENT GROUT
115 16
115 16
2" 5/8"
SAWCUT EXISTING
MASONRY
WALL AS REQUIRED TO
RECEIVE NEW OPENING
REPAIR ALL DAMAGE
PLASTER AS REQUIRED
TO MATCH AND ALIGN
WITH ADJACENT SURFACE
HM FRAME
FILL VOID SOLID
WITH CEMENT
GROUT
SEALANT / FIRE STOP ASSEMBLY AT
RATED WALL (TYPICAL BOTH SIDES)
REPAIR DAMAGED AREAS
AND FILL VOID
WITH CEMENT GROUT
1/4"
MASONRY ANCHOR
PER MANUFACTURER
115 16
115 16
2" 5/8"
SAWCUT EXISTING
MASONRY
WALL AS REQUIRED TO
RECEIVE NEW OPENING
REPAIR ALL DAMAGE
PLASTER AS REQUIRED
TO MATCH AND ALIGN
WITH ADJACENT SURFACE
HM FRAME
FILL VOID SOLID WITH
CEMENT GROUT
SEALANT / FIRE STOP ASSEMBLY AT
RATED WALL (TYPICAL BOTH SIDES)
REPAIR DAMAGED
AREAS
AND FILL VOID
WITH CEMENT
GROUT
1/4"
MASONRY ANCHOR
PER
MANUFACTURER
EXISTING MASONRY BLOCK
WITH
CERAMIC TILE FINISH
JAMB
THIN SET TILE1/2
" 1/4
" 3
4" FRAME BACKBEND1/4
1/4
1/4
2" 5/8
16"115
16"
1/2"1/2"
SEALANT ALL
AROUND
SEALANT
ALL
AROUND
NOMINAL CMU
SEE PARTITION TYPES
BOND BEAM
LINTEL
(REINFORCEMENT
PER LINTEL
SCHEDULE)
HM FRAME
1'- 4"
HEAD
(OPENINGS 5'-4" TO MAX 8'-0" WIDE)
GROUT SOLID
2" 5/8
16"115
16"
1/2"1/2"
SEALANT ALL
AROUND
SEALANT ALL
AROUND
NOMINAL CMU
SEE PARTITION TYPES
BOND BEAM
LINTEL
(REINFORCEMENT
PER LINTEL
SCHEDULE)
HM FRAME
HEAD
OPENINGS LESS THAN 5'-4" WIDE)
GROUT SOLID
ADD RETURN
ON FRAME WHERE
DRYWALL FINISH
IS REQUIRED
1/2"*1/2"*
2"
5/8
1 15/16" VARIES 1 15/16"
GAGE AS
SPECIFIED
STANDARD DOOR FRAME
* 2
C
MU
H
EA
DE
R
7'
-2 " D
OO
R
4"
C
MU
H
EA
DE
R
7'
-0 " D
OO
R
* 34" BACKBENDS FOR
TILE TO BUTT AGAINST
WHERE TILE IS
SCHEDULED
SEE DOOR SCHEDULE
SE
E
DO
OR
S
CH
ED
UL
E
SEE DOOR SCHEDULE
F1
F2
2"
SE
E
DO
OR
S
CH
ED
UL
E
*4" @ CMU
HEADER @ 7'-0"
DOOR
F3 - DOUBLE
EGRESS
2" / 4
3/8" X 3" EXPANSION
ANCHOR
NOTE: REFER TO SPECS & SECURITY DWGS
FOR HARDWARE SETS AND LOCATIONS.
COORDINATE WITH ELECTRICAL SECURITY PLANS
CYL
MORTISE LOCK CASE
1 1/2" x 3/4" x 1/8" STEEL FRAMING
CHANNEL (HORIZ. AND VERTICAL)
LEVER ACTUATOR
STAINLESS STEEL
PULL
2" NO. 6 GA.
DIAMOND WIRE
MESH
1 1/2" PAIR OF 3 1/2"
HEAVY DUTY
HINGES - NRP
CORRIDOR G113 SIDE
5"
2- 1/8
1/8"
2" JAMB OPENING WIDTH
FINISHED DOOR WIDTHFINISHED DOOR WIDTH
CAM-LIFT HINGE 1/8"
1/8"
2"
SEMI-MORTISED
ASTRAGAL
SCHEDULED
LOCKSET
HARDWARE
SEALANT ALL
AROUND
GROUT
ADJUSTABLE
ANCHORS
NO
M
CM
U
1/2
1/2
GROUT CELL SOLID
AT ANCHORS
FRAMES IN MASONRY PARTITION
JAMB
SOUND SEAL
JA
MB
O
PE
NI
NG
H
EI
GH
T
FI
NI
SH
ED
D
OO
R
HE
IG
HT
DOOR
BOTTOM
SEAL
3/1 6"
1/8 "2"
SEALANT ALL
AROUND
NOMINAL CMU
SEE PARTITION TYPES
BOND BEAM
LINTEL
(REINFORCEMENT
PER LINTEL
SCHEDULE)
GROUT SOLID
THRESHOLD SET IN BED
OF SEALANT
FINISHED FLOOR
HEAD & THRESHOLD
(OPENINGS 5'-4" TO MAX 8'-0" WIDE)
SEALANT & BACKER ROD
8" BENT HD GALV. STL
PLATE THRESHOLD W/ (3)
4" DIA. F.H. CTSK BOLTS &
EXP ANCHORS (MIN.)
LINE OF WALL BEYOND
CMU W/ CORES GROUTED
SOLID
DRILL AND EPOXY
ANCHOR # 5 DOWEL
AT 16" O.C. @ THE
THRESHOLD
3"
SCHEDULED DOOR /
FRAME / HDW
FLOOR LINE - EXISTING
SLAB
CONT. SHIM SPACERS
WELDED TO THRESHOLD
8" 1/4
1 1
/2"
1/2"
2"
NTSA1 SIDE-HINGED DOOR TYPES
B-AE601
DOOR SCHEDULE & DETAILS
DZ JH / DZ
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh 1, 2 and 6
Key Plan
Balance of Work
9/12/2022
NTSA3 FRAME TYPES
3" = 1'-0"D1 CMU FRAMES
0 3" 6" 9"
E4 HEAD - EXISTING CMU / PLASTERE1 JAMB - EXISTING CMU / PLASTER
1121W 1121W STAIR 3' - 8" 7' - 0" HM HM 90
DOOR AND FRAME / GATE DOOR SCHEDULE
IDENTIFICATION DIMENSIONS PANEL FRAME
FIRE
RATING
HARDWARE
GROUP NOTESDOOR NO ROOM NO ROOM NAME
WIDTH
H TYPE MATERIAL FINISH GLAZING TYPE MATERIAL FINISH
DETAILS
W1 W2
TOTAL
WIDTH HEAD JAMB
714 714 STORAGE 3' - 0" 7' - 0" 6 HM PT - F1 HM PT E4/B-AE601 E1/B-AE601 45 HW-5
715 715 SHAFT 2' - 6" 7' - 0" 6 HM - F1 HM HW-5 REPLACE DOOR AND FRAME IN EXISTING WALL OPENING. VERIFY DIMENSIONS IN
FIELD PRIOR TO FABRICATION AND INSTALLATION OF NEW DOOR AND FRAME.
G383 G383 FEMALE TOILET 3' - 0" 7' - 0" 6 HM - HM HW-1
G605 G605 FEMALE LOCKER
3' - 0"
7' - 0" 6 HM - HM 45 HW-SH-1A
G609 G609 STORAGE 2' - 6" 7' - 0" 6 HM
FR-1
HM HW-5-
G611 G611 TOILET 3' - 0" 7' - 0" 6 HM - HM HW-2D
G607.1 G607 BREAK AREA
G383A G383A LACTATION ROOM 3' - 0" 7' - 0" 6 HM - HM
3' - 0"
G603 G603 MALE LOCKER 7' - 0" 6 HM - HM 45 HW-SH-1A3' - 0"
7' - 0" 2 HM HM 45 HW-SH-1A
HW-2D
HW-6
LEVEL
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
PT
D1/B-AE601 D1/B-AE601
3 FR-12
3" = 1'-0"C1 INTERIOR DOOR FRAMES
0 3" 6" 9"
3" = 1'-0" 0 3" 6" 9"
0 3" 6" 9" 3" = 1'-0"
F1 F1 F1 F1 F1
F1 F1
F1
E4/B-AE601 E1/B-AE601
E4/B-AE601 E1/B-AE601
E4/B-AE601 E1/B-AE601
D1/B-AE601 D1/B-AE601
D1/B-AE601 D1/B-AE601
D1/B-AE601 D1/B-AE601
D1/B-AE601 D1/B-AE601
E4/B-AE601 E1/B-AE601
PROVIDE 34" BACKBENDS AT FRAME FOR TILE FINISH
PROVIDE 34" BACKBENDS AT FRAME FOR TILE FINISH
G956
G954 MECHANICAL ROOM 3' - 0" 7' - 0" HM HM - HW-11APT PT3 -6/6 F2
G632 G632 TEL RM 3' - 0" 7' - 0" 6 HM - HM HW-SH-32 PT PT -F1 D1/B-AE601 D1/B-AE601
F1 JAMBS - WIRE MESH SWING GATE
0 3" 6" 9" 3" = 1'-0"
3' - 0" -G607.2 G607 BREAK AREA 7' - 0" - - HM 45 HW-SH-1A- PT PTF1 D1/B-AE601 D1/B-AE601 RE-INSTALL SALVAGED DOOR INTO NEW HM FRAME. COORDINATE HINGE LOCATIONS.
*NOTE: VERIFY ALL DIMENSIONS BASED UPON FIELD CONDITIONS PRIOR TO FABRICATION OR INSTALLATION, TYPICAL TO ALL DOOR OPENINGS.
G113A G113 CORRIDOR 3' - 0" 6' - 0" WM STL - HW-G1PREFIN PREFIN- -WM - - F1/B-AE601 SEE SPECIFICATION SECTION 10 22 13 FOR REMAINDER OF HARDWARE
D1/B-AE601 D1/B-AE6013' - 0" 6' - 0"
G956 MECHANICAL ROOM 3' - 0" 7' - 0" HM HM - HW-9BPT PT3 -6/6 F2 D6/B-AE601 D6/B-AE6013' - 0" 6' - 0"
G954
ME.01 EXTERIOR MECHANICAL EXTERIOR 3' - 0" 8' - 0" FENCE STL PIPE - HW-E4CPOLYMER
COAT
POLYMER
COAT
- -FENCE - - - SEE SPECIFICATION SECTION 32 31 13 FOR REMAINDER OF HARDWARE.; PROVIDE
POLYMER COAT (BLACK) TO MATCH FENCE FABRIC.
STC
3" = 1'-0"D6 CMU FRAMES - STC RATED
0 3" 6" 9"
G953A
G953 BUILDING SUPPORT 3' - 0" * 7' - 0" * HM HM - HW-9APT PT- - F2 * - -3' - 0" * 6' - 0" *
G953 BUILDING SUPPORT HM HM - HW-9APT PT- - F2 * - -
G953 -
3' - 0" * 7' - 0" *3' - 0" * 6' - 0" *
* EXISTING DOOR & FRAME; SUPPLEMENTAL HARDWARE INSTALLATION ONLY.
REMOVE EXISTING DOOR COORDINATOR; PATCH AND REPAIR HOLES IN DOOR AND
FRAME AND REPAINT ENTIRE DOOR / FRAME. PROVIDE GROUT AT THRESHOLD AS
REQUIRED FOR DIFFERENCE AT SLAB / FINISH FLOOR ELEVATION.
- * EXISTING DOOR & FRAME; SUPPLEMENTAL HARDWARE INSTALLATION ONLY.
REMOVE EXISTING DOOR COORDINATOR; PATCH AND REPAIR HOLES IN DOOR AND
FRAME AND REPAINT ENTIRE DOOR / FRAME. PROVIDE GROUT AT THRESHOLD AS
REQUIRED FOR DIFFERENCE AT SLAB / FINISH FLOOR ELEVATION.
F6 THRESHOLD - CMU
0 3" 6" 9" 3" = 1'-0"
SEE DETAIL F2 / B-AE601 FOR ELEVATED THRESHOLD REQUIREMENTS.
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
AutoCAD SHX Text
BLDG 6
BOND BEAM W/2 # 5 GROUT
SOLID
CEILING LINE (AS SCHEDULED)
HORIZ. JOINT REINF @16"OC
CUT TOP COURSE TO FIT
STRUCTURAL DECK
FLOOR LINE
VERTICAL REINFORCING # 5 @
48 IN OC, GROUT SOLID
B-AE603
C8/D8
LAP VERTICAL REINFORCING
30 IN, TYP.
GROUT FIRST COURSE SOLID
(ENTIRE LENGTH OF WALL)
DRILL AND EPOXY ANCHOR # 5 DOWEL
AT 32" O.C.
B-AE603
F8
HIGHER PRIORITY WALL
LOWER PRIORITY WALL
HIGHER PRIORITY WALL
LOWER PRIORITY WALL
HIGHER PRIORITY WALL
(MAINTAIN CONTINUITY)
NOTES:
WHERE WALLS OF DIFFERENT FUNCTIONS/ RATINGS INTERSECT:
WALLS OF HIGHER PRIORITY SHALL BE CONTINUOUS.
LOWER PRIORITY WALLS SHALL "ABUT" AND BE "SEALED TO"
HIGHER PRIORITY WALLS, BUT SHALL NOT INTERRUPT CONTINUITY
OF THE HIGHER PRIORITY WALL.
WALL PRIORITY LEGEND
WALL FUNCTION PRIORITY
1 HR FIRE & SMOKE
1 HR FIRE
SOUND CONTROL WALLS (NON FR)
SMOKE PARTITIONS (NON FR)
OTHER WALLS
HIGHER
LOWER
4 HR FIRE & SMOKE
3 HR FIRE & SMOKE
2 HR FIRE & SMOKE
2 HR FIRE
HVAC
DUCT
SECTION ELEVATION
HVAC
DUCT
CMU WALL
FOR DUCT LARGER THAN 2'-0"
PROVIDE CMU BOND BEAM
LINTEL (SEE SCHEDULE - BELOW)
18 GA GALV FLANGE @
ALL SIDES ATTACH TO
METAL DUCT
FIRE RETARDANT SEALANT
@ DUCT & WALL FLANGES
1 1 /4"
MINERAL FIBER FIRE SAFEING
AND INTUMESCENT SEALANT
4"-12" CMU WALLS (SEE
FLOOR PLANS FOR PARTITION
TYPES
3" x 3" CONT 18 GA
GALV FLANGE (ALL
SIDES)
*NOTE: SEE FIRESTOP ASSEMBLY DETAILS ON B-AE508 FOR ADDITIONAL REQUIREMENTS
DU
CT
W
OR
K
SEE LINTEL SCHEDULE
ON THIS SHEET
FIRE DAMPER WITH
STL CLOSURE ANGLE
BOTH SIDES OF WALL
CMU PARTITION
(FIRE RATED)
FIRE DAMPER; SEE MECHANICAL
INTUMESCENT SEALANT ALL SIDES
MINERAL FIBER SAFEING AND
INTUMESCENT SEALANT
DETAIL 1A - "FIRE-RATED WALLS"- ADDITIONAL NOTES:
1. CONDITIONS INDICATED TO SHOW DESIGN INTENT. THEY ARE NOT INTENDED TO BE PROPRIETARY. CONTRACTOR MAY EMPLOY SIMILAR A UL-APPROVED TOP-OF-WALL DESIGNS THAT ARE APPROPRIATE FOR CONDITIONS.
2. REFER TO SPECIFICATION SECTION 07 84 00 / "FIRESTOPPING" FOR ADDITIONAL REQUIREMENTS REGARDING HEAD-OF-WALL CONDITION FOR FIRE-RATED WALLS.
SLOTTED TOP TRACK
STUD
DESIGN BASIS: UL-HW-D-0042
METAL DECK
(PERPENDICULAR TO FLUTES)
DESIGN BASIS: UL-HW-D-0264
METAL DECK
(PARALLEL TO FLUTES)
1" 1" 2"x20 GA STRAPS @ 16" O.C.
DESIGN BASIS: UL-HW-D-0259
STEEL BEAM
20 GA Z-BARS TO
ACCOMMODATE
SFRM
SPRAY-APPLIED
FIRE-RESISTIVE
MATERIAL (SFRM)
FIBER BLANKET (SAB)
1 OR 2 LAYERS OF GWB; SEE
WALL TYPE
FIRE STOP JOINT SPRAY
MINERAL WOOL FORMING
MATERIAL
3/4 " 3/4
FIRE STOP JOINT SPRAY
SLOTTED TOP TRACK
STUD
FIBER BLANKET (SAB)
1 OR 2 LAYERS OF GWB; SEE
WALL TYPE
3/4
MINERAL WOOL
FORMING MATERIAL
HVAC
DUCT
SEALANT & BACK-UP FIRESTOP
SEALANT @ RATED WALLS (ALL SIDES)
TYPE 'X' GYP BD ENLOSURE
WHERE OPNG WIDTH EXCEEDS
8'-0"
HVAC
DUCT
#5 REBAR @ JAMBS OF OPENING
SEE TOP OF WALL DETAIL C8 & D8/C-AE603
FINISHED FLOOR
UNDERSIDE OF STRUCTURE
ABOVE OR TOP OF
PARTITION
CORNER / END OF
PARTITION MASONRY
OPENING
SEE LINTEL SCHEDULE
ON THIS SHEET - BELOW
#4 BAR TYP GROUT
CORES SOLID
SEE TOP OF WALL DETAILS
OF CMU PARTITIONS
NOTE:
SEE DETAIL FOR TYPICAL
REINFORCING
MASONRY
OPENING
SECTION ELEVATION
EXISTING
CONCRETE
WALL W/ SAW
CUT OPN'G
EXISTING CONCRETE WALL:
3/8" THICK ANGLE
EACH SIDE W/ 5 - 3/8" DIA
EXPANSION ANCHORS
(EMBEDMENT = 2")
OP
EN
IN
G
HE
IG
HT
4"
A
A
BB
6"
8" 8"
6"
1. SEE FLOOR PLANS FOR EXTENT OF EACH WALL TYPE.
2. WALL TYPES ARE TITLED TO GENERALLY DESCRIBE AN
ASSEMBLY'S FIRE-RESISTIVE "CAPABILITY". IN SOME
CASES, ARCHITECT MAY HAVE EMPLOYED A GIVEN WALL
TYPE FOR ITS SOUND CONTROL OR OTHER PROPERTIES.
THUS IT IS POSSIBLE THAT WALL TYPES CHOSEN MAY
PROVIDE GREATER FR CAPABILITY THAN ACTUALLY
REQUIRED BY BUILDING CODE. UTILIZE WALL TYPES
INDICATED BY FLOOR PLAN CALL-OUTS.
3. CONTACT ARCHITECT WHERE WALLS LACK A WALL TYPE
CALL-OUT.
4. "STC" REFERS TO SOUND TRANSMISSION CLASS; A
RATING SYSTEM THAT DESCRIBES THE ABILITY OF AN
ASSEMBLY TO REDUCE THE TRANSMISSION OF SOUND.
CONFIGURE SOUND-RATED WALL ASSEMBLIES
ACCORDING TO THE MINIMUM REQUIREMENTS
STIPULATED IN THE STC TESTS LISTED.
5. "SAB" REFERS TO SOUND ATTENUATION BATTS
SPECIFIED IN SECTION 07 21 13. WHERE SAB ARE
INDICATED, THEY SHALL EXTEND CONTINUOUSLY FROM
FLOOR TO STRUCTURE ABOVE. SEE CONSTRUCTION / ICRA
BARRIERS WHERE SAB ARE ALSO REQUIRED.
6. HEAD-OF-WALL FIRESTOPPING AND SEALING OF THRU-
WALL PENETRATIONS: REFER TO SECTION 07 84 00 /
FIRESTOPPING.
7. ACOUSTICAL SEALANTS: SPECIFIED IN SECTION 09 29 00.
8. AT CMU INFILL OF OPENINGS AND CONTINUATIONS OF
EXISTING WALLS, CMU SHALL BE TOOTHED INTO EXISTING
ADJACENT MASONRY.
CMU (SASH BLOCK)
PREMOLDED CONTROL JOINT @
NON-RATED CMU ONLY, DELETE
PREMOLDED CONTROL JOINTS &
REFER TO THE UL DIRECTORY FOR
UL LISTED RATED JOINT DESIGNS.
MATCH RATING OF JOINT DESIGN
TO PARTITION RATING.
SEALANT AND BACKER ROD @
NON-RATED PARTITION
FIRE RATED JT ASSEMBLY @ RATED
PARTITION (EACH SIDE)
NOTE: DO NOT BRIDGE CONTROL JOINT
WITH HORIZONTAL REINFORCEMENT
SCHEDULED CMU
GROUT SOLID AROUND
FIRE EXTINGUISHER
CABINET
8" MIN
" M
IN
SCHEDULED CMU
NOTES: 1. FIRE EXTINGUISHER TO BE RECESSED AND SUPPORTED BY CMU WALL AND SEALED
AROUND ALL EDGES.
2. PROVIDE FIRE RATED CABINET IN ALL RATED WALLS
3. NOTIFY ARCHITECT PRIOR TO FABRICATION, WHERE WALL DEPTH IS NOT SUFFICIENT TO
ACCEPT A FULLY RECESSED FIRE EXTINGUISHER CABINET.
GROUT SOLID AROUND
FIRE EXTINGUISHER
CABINET (ALL SIDES)
8" MIN
" M
IN
PLAN SECTION
2 12 GALLON FIRE
EXTINGUISHER
(JSN # A1000)
2 12 GALLON FIRE
EXTINGUISHER
(JSN#A1000)
STRUCTURAL DECK
3" X 4.1# STEEL CAPRAIL WITH
"U" BOLYS AT 2'-4" O.C.
1 14" X 12" X 18" CHANNEL FOR
CENTRAL RAILS (2) REQUIRED
2" NO. 6 GA DIAMOND
WIRE MESH
1 12" X 34" X 18" STEEL FRAMING
CHANNEL
FLAT BAR AS REQUIRED BY
SPECIFICATION
CAST FLOOR SHOE W/
(2) 38" X 1 78" STUD
EXPANSION BOLTS
4" X 2" X 14" THICK STEEL ANGLE CLIP
WITH 38" STUD EXPANSION BOLTS
CONC CURB / FIN FLR
SLAB
BOND BEAM W/2 # 5 GROUT
SOLID
HORIZ. JOINT REINF @16"OC
STRUCTURAL DECK
FLOOR LINE
VERTICAL REINFORCING # 5 @
48 IN OC, GROUT SOLID
LAP VERTICAL REINFORCING
30 IN, TYP.
GROUT FIRST COURSE SOLID
(ENTIRE LENGTH OF WALL)
DRILL AND EPOXY ANCHOR # 5 DOWEL
AT 32" O.C.
B-AE603
F8
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh 1, 2 and 6
Key Plan
Balance of Work
9/12/2022
B-AE603
DZ JH / DZ
0 3" 6" 9" 1" = 1'-0"C1 DUCTS THRU CMU WALLS (TYPICAL)
3"=1'-0" 1" = 1'-0"D4 HEAD OF WALL CONDITIONS - STUD WALLS - GYP BD
0 6" 1'-0" 2'-0"
3/4" = 1'-0"F7 LARGE DUCT OPENING THRU CMU WALL
0 1'-0" 2'-0" 3'-0"
1 1/2" = 1'-0"E5 ELEVATION VIEW - REINFORCING AT TYPICAL OPENINGS AT CMU PARTITION
0 6" 1'-0" 1'-6" 1" = 1'-0"E1 OPENING THRU EXISTING CONCRETE AND CMU WALLS
0 6" 1'-0" 2'-0"
1" = 1'-0"F1
0 6" 1'-0" 2'-0" NTSF2 MASONRY WALL STEEL LINTEL SCHEDULE
0 6" 1'-0" 2'-0"
NTSB1 WALL PRIORITY LEGEND
CMU PARTITION - DETAIL
Y
NTSF4 TYP. BOND BEAM LINTEL SCHEDULE AND DETAILS UNLESS NOTED OTHERWISE
1 1/2" = 1'-0"C8
INTERIOR NON-BEARING MASONRY WALLS REINFORCEMENT - DETAILS
0 6" 1'-0" 1'-6"
1 1/2" = 1'-0"D8
INTERIOR NON-BEARING MASONRY WALLS REINFORCEMENT
WALL PERPENDICULAR TO DECK - DETAILS
0 6" 1'-0" 1'-6"
1 1/2" = 1'-0"F8 0 6" 1'-0" 1'-6"
PARTITION TYPES
INTERIOR NON-BEARING MASONRY WALLS REINFORCEMENT
WALL PARALLEL TO DECK - DETAILS
MARK
CMU
SIZE FIRE RATING
FIRE-RESISTANCE
SOUND
ATTENUATION
CommentsUL NO. STC
Y4 3 5/8" - - 44-47
Y6 5 5/8" - - 46-57
Y8 7 5/8" - - 48-55
Y61 5 5/8" 1 HOUR / SMOKE U906 46-57
Y62 5 5/8" 2 HOUR / SMOKE U906 46-57
Y6A 5 5/8" 51 GROUT FILL SOLID THE ENTIRE WALL; MINERAL WOOL PACK
SEAL ALL VOIDS & PENETRATIONS
PROVIDE MINERAL WOOL PACKING AT ALL WALL VOIDS
PROVIDE MINERAL WOOL PACKING AT ALL WALL VOIDS
PROVIDE MINERAL WOOL PACKING AT ALL WALL VOIDS
PARTITION GENERAL NOTES
1" = 1'-0"E2 CONTROL JOINT @ CMU
0 6" 1'-0" 2'-0"
FE CABINET (2 12 GALLON) DETAILS
W1
WIRE MESH PARTITION
PARTITION TYPES AND DETAILS
MARK
CMU
SIZE FIRE RATING
FIRE-RESISTANCE
SOUND
ATTENUATION
CommentsUL NO. STC
M6 5 5/8" - - - -
M
CMU PARTITION - DETAIL
SCALE: NONE SCALE: NONE
SCALE: NONE
AutoCAD SHX Text ATTACH 4"x4"x "x8" LONG 14"x8" LONG ANGLES TO PLATE @ 4'-0" O.C. W/ WELDING OR EXPANSION BOLTS, 2 PER ANGLE, 560-LB TOTAL SHEAR CAPACITY (TYP.) STAGGER ANGLES
AutoCAD SHX Text 8"x18"x " THICK 18" THICK PLATE, SEE NOTES
AutoCAD SHX Text
SEE NOTE 3
AutoCAD SHX Text #5 @ 32" O.C. (DOWELS) AT NEW CONCRETE SLABS AT EXISTING SLAB PROVIDE #5 DRILLED AND SET W/ EPOXY IN SLAB AT 32" O.C.
AutoCAD SHX Text TWO " DIA. x 3" MIN. 58" DIA. x 3" MIN. EMBEDMENT EXPANSION BOLTS EACH SIDE
AutoCAD SHX Text TWO " DIA. x 3" MIN. 58" DIA. x 3" MIN. EMBEDMENT EXPANSION BOLTS PER ANGLE.
AutoCAD SHX Text L 4x4x "x8" LONG @ 4'-0" O.C. EACH 14"x8" LONG @ 4'-0" O.C. EACH SIDE OF WALL (TYP). STAGGER ANGLES
AutoCAD SHX Text MINERAL WOOL PACKING FOR ALL WALLS. AT FIRE RATED / SMOKE WALLS, PROVIDE CONT. FIRE STOP JOINT SPRAY WITH 2" MIN. OVERLAP (EA SIDE)
AutoCAD SHX Text NOTES: 1. PROVIDE INTERMDIATE PLATE WHEN FLUTES OF METAL DECK ARE PREVENTING ATTACHMENT OF ANGLE DIRECTLY. 2. DO NOT BEND OR HEAT DOWELS.
AutoCAD SHX Text MINERAL WOOL PACKING FOR ALL WALLS. AT FIRE RATED / SMOKE WALLS PROVIDE CONT. FIRE STOP JOINT SPRAY WITH 2" MIN. OVERLAP (EA SIDE)
AutoCAD SHX Text
3. MIN 1 " DISTANCE TO BOLT LOCATION TO THE EDGE OF PLATE 12" DISTANCE TO BOLT LOCATION TO THE EDGE OF PLATE AND/OR DECK IS REQUIRED.
AutoCAD SHX Text
4. BREAK CORE WALLS WHERE INTERFERENCE WITH DOWELS OCCURS. 5. LOCATION OF #4 SLAB BARS TO BE COORDINATED THROUGH THE SHOP DRAWING PROCESS. 6. WALL FINISH IS SHOWN ON ARCH. DWGS. 7. REFER TO FIRESTOPPING DETAILS FOR RATED PARTITIONS.
AutoCAD SHX Text
BASIS OF DESIGN: UL-HW-D-1045
AutoCAD SHX Text CUT TOP COURSE AS REQUIRED TO FIT MAX 3 " GAP FROM B/O DECK / SLAB12" GAP FROM B/O DECK / SLAB
AutoCAD SHX Text
BOND BEAM PER PARTITION SCHEDULE
AutoCAD SHX Text
BOND BEAM PER PARTITION SCHEDULE
AutoCAD SHX Text
SECTION
AutoCAD SHX Text
NOMINAL
AutoCAD SHX Text
SIZE (IN)
AutoCAD SHX Text
LINTEL
AutoCAD SHX Text
REQUIRED REINFORCING FOR CLEAR SPAN
AutoCAD SHX Text 6x8
AutoCAD SHX Text 6x16
AutoCAD SHX Text 8x8
AutoCAD SHX Text 8x16
AutoCAD SHX Text L<=3'-4"
AutoCAD SHX Text 1-#4
AutoCAD SHX Text 1-#4
AutoCAD SHX Text 2-#4
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 1-#4
AutoCAD SHX Text 2-#4
AutoCAD SHX Text 4'-8"
AutoCAD SHX Text 1-#4
AutoCAD SHX Text 2-#4
AutoCAD SHX Text 5'-4"
AutoCAD SHX Text 2-#4
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 6'-8"
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 7'-4"
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text 2-#5
AutoCAD SHX Text 2-#5
AutoCAD SHX Text NOTES: 1. WALL LOAD ASSUMED 300 lbs. PER LINEAR FOOT MAX. WALL LOAD ASSUMED 300 lbs. PER LINEAR FOOT MAX. 2. LINTELS ARE REQUIRED FOR ANY OPENING EXCEEDING 12".LINTELS ARE REQUIRED FOR ANY OPENING EXCEEDING 12".
AutoCAD SHX Text NOTES: 1. PROVIDE BLOCK LINTELS FOR ALL OPENINGS IN INTERIOR BLOCK PARTITIONS PROVIDE BLOCK LINTELS FOR ALL OPENINGS IN INTERIOR BLOCK PARTITIONS AND WALLS FOR WHICH STEEL LINTELS ARE NOT SHOWN. 2. PROVIDE 8" MIN. BEARING AT EACH END. PROVIDE 8" MIN. BEARING AT EACH END. 3. REFER TO ARCH. DWGS. FOR SIZE AND LOCATION OF DOOR, LOUVER AND REFER TO ARCH. DWGS. FOR SIZE AND LOCATION OF DOOR, LOUVER AND WINDOW OPENINGS. COORDINATE WITH HVAC AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF DUCT(S) AND GANGED ELECTRICAL CONDUIT OPENINGS. 4. GROUT FOR BOND BEAMS TO COMPLY WITH ASTM C476, 3000 PSI GROUT, GROUT FOR BOND BEAMS TO COMPLY WITH ASTM C476, 3000 PSI GROUT, FOR REINFORCED MASONRY. 5. EMBED WALL REINFORCEMENT INTO BOND BEAM, SEE "INTERIOR WALL EMBED WALL REINFORCEMENT INTO BOND BEAM, SEE "INTERIOR WALL REINFORCEMENT ELEVATION" FOR REINFORCEMENT.
AutoCAD SHX Text
CMU LINTEL SCHEDULE
AutoCAD SHX Text #3 16"O.C.
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text
SEE NOTE 5
AutoCAD SHX Text
GROUT CELLS SOLID
AutoCAD SHX Text
REBARS, SEE LINTEL SCHEDULE
AutoCAD SHX Text
REBARS SEE SCHEDULE BELOW
AutoCAD SHX Text
GROUT CELLS SOLID
AutoCAD SHX Text
SEE NOTE 5
AutoCAD SHX Text
FOR CLEAR OPENINGS 5'-4" TO MAX. 8'-0" WIDE
AutoCAD SHX Text N.T.S.
AutoCAD SHX Text 8"
AutoCAD SHX Text 8"
AutoCAD SHX Text 6"
AutoCAD SHX Text 8"
AutoCAD SHX Text 1'-4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 8"
AutoCAD SHX Text 1'-4"
AutoCAD SHX Text 1"
AutoCAD SHX Text
%%UFOR CLEAR OPENINGS LESS THAN 5'-4" WIDE
AutoCAD SHX Text
FINISH
AutoCAD SHX Text 6"
AutoCAD SHX Text
(TYP.)
AutoCAD SHX Text LINTEL NOTES: 1. PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENINGS EXCEEDING 12" WIDE IN PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENINGS EXCEEDING 12" WIDE IN ACCORDANCE WITH THE SCHEDULE ABOVE. INSTALL LONG LEG VERTICAL. 2. OPENING WIDTH SHALL BE CLEAR WIDTH TO BLOCK WALL. OPENING WIDTH SHALL BE CLEAR WIDTH TO BLOCK WALL. 3. PROVIDE LINTELS AT ALL MECHANICAL OPENINGS AND GANG ELECTRICAL CONDUIT PROVIDE LINTELS AT ALL MECHANICAL OPENINGS AND GANG ELECTRICAL CONDUIT PENETRATIONS OF MASONRY WALLS. COORDINATE SIZE AND LOCATIONS OF OPENINGS WITH APPROPRIATE TRADES. 4. PROVIDE 6" MINIMUM BEARING AT EACH END, BUT NOT LESS THAN 1" PER FOOT OF SPAN. PROVIDE 6" MINIMUM BEARING AT EACH END, BUT NOT LESS THAN 1" PER FOOT OF SPAN. FILL 2 COURSES OF MASONRY BELOW BEARING POINT WITH GROUT. 5. WHERE MINIMUM BEARING CANNOT BE PROVIDED, ATTACH SECURELY TO ADJACENT WHERE MINIMUM BEARING CANNOT BE PROVIDED, ATTACH SECURELY TO ADJACENT STRUCTURAL MEMBERS OR PROVIDE SEPARATE SUPPORT. 6. WHERE LINTELS OCCUR IN EXTERIOR WALLS, MINIMUM ANGLE THICKNESS SHALL BE " AND WHERE LINTELS OCCUR IN EXTERIOR WALLS, MINIMUM ANGLE THICKNESS SHALL BE " AND 516" AND SHALL BE HOT DIPPED GALVANIZED. 7. WHERE WALL THICKNESS EXCEEDS 12", PROVIDE ONE ADDITIONAL ANGLE FOR EACH ADDITION WHERE WALL THICKNESS EXCEEDS 12", PROVIDE ONE ADDITIONAL ANGLE FOR EACH ADDITION OF 4" OF WALL. 8. THIN FILM INTUMESCENT FIRE-RESISTIVE MATERIAL SHALL BE APPLIED TO ALL SURFACES OF THIN FILM INTUMESCENT FIRE-RESISTIVE MATERIAL SHALL BE APPLIED TO ALL SURFACES OF INTERIOR LINTELS AT OPENINGS EXCEEDING 4'-0"; SEE SPECIFICATION SECTION 07 81 23.
AutoCAD SHX Text
MAX. WALL OPENING
AutoCAD SHX Text 3'-0"
AutoCAD SHX Text L5x3 x 12x 14
AutoCAD SHX Text
MASONRY WALL THICKNESS
AutoCAD SHX Text L3 x3x 12x3x 14
AutoCAD SHX Text L4x3 x 12x 14
AutoCAD SHX Text L4x3 x 12x 14
AutoCAD SHX Text
4" WALL
AutoCAD SHX Text
6" WALL
AutoCAD SHX Text
8" WALL
AutoCAD SHX Text
12" WALL
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 5'-0"
AutoCAD SHX Text 6'-0"
AutoCAD SHX Text 8'-0"
AutoCAD SHX Text L6x3 x 12x 14
AutoCAD SHX Text 2- L3 x2 x 12x2 x 12x 14
AutoCAD SHX Text 2- L3 x2 x 12x2 x 12x 14
AutoCAD SHX Text 2- L3 x2 x 12x2 x 12x 14
AutoCAD SHX Text 2- L3 x2 x 12x2 x 12x 14
AutoCAD SHX Text 2- L3 x2 x 12x2 x 12x 14
AutoCAD SHX Text 2- L3 x3 x 12x3 x 12x 14
AutoCAD SHX Text 2- L4x3 x 12x 14
AutoCAD SHX Text 2- L5x3 x 12x 14
AutoCAD SHX Text 2- L5x3x 14
AutoCAD SHX Text 2- L6x3 x 12x 38
AutoCAD SHX Text 10'-0"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text W 8x28 W/ 12" BEARING EA SIDE
AutoCAD SHX Text W 10x49 W/ 12" BEARING EA SIDE
AutoCAD SHX Text
MASONRY WALL STEEL LINTEL SCHEDULE
AutoCAD SHX Text 2- L5x5x 516
AutoCAD SHX Text 2- L5x5x 516
AutoCAD SHX Text 2- L5x5x 38
AutoCAD SHX Text 2- L5x5x 12
AutoCAD SHX Text 2- L5x5x 58
AutoCAD SHX Text LINTEL NOTES: 1. PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENINGS EXCEEDING 12" WIDE IN PROVIDE AND INSTALL LINTEL ANGLES FOR MASONRY OPENINGS EXCEEDING 12" WIDE IN ACCORDANCE WITH THE SCHEDULE ABOVE. INSTALL LONG LEG VERTICAL. 2. OPENING WIDTH SHALL BE CLEAR WIDTH TO BLOCK WALL. OPENING WIDTH SHALL BE CLEAR WIDTH TO BLOCK WALL. 3. PROVIDE LINTELS AT ALL MECHANICAL OPENINGS AND GANG ELECTRICAL CONDUIT PROVIDE LINTELS AT ALL MECHANICAL OPENINGS AND GANG ELECTRICAL CONDUIT PENETRATIONS OF MASONRY WALLS. COORDINATE SIZE AND LOCATIONS OF OPENINGS WITH APPROPRIATE TRADES. 4. PROVIDE 6" MINIMUM BEARING AT EACH END, BUT NOT LESS THAN 1" PER FOOT OF SPAN. PROVIDE 6" MINIMUM BEARING AT EACH END, BUT NOT LESS THAN 1" PER FOOT OF SPAN. FILL 2 COURSES OF MASONRY BELOW BEARING POINT WITH GROUT. 5. WHERE MINIMUM BEARING CANNOT BE PROVIDED, ATTACH SECURELY TO ADJACENT WHERE MINIMUM BEARING CANNOT BE PROVIDED, ATTACH SECURELY TO ADJACENT STRUCTURAL MEMBERS OR PROVIDE SEPARATE SUPPORT. 6. WHERE LINTELS OCCUR IN EXTERIOR WALLS, MINIMUM ANGLE THICKNESS SHALL BE " AND WHERE LINTELS OCCUR IN EXTERIOR WALLS, MINIMUM ANGLE THICKNESS SHALL BE " AND 516" AND SHALL BE HOT DIPPED GALVANIZED. 7. WHERE WALL THICKNESS EXCEEDS 12", PROVIDE ONE ADDITIONAL ANGLE FOR EACH ADDITION WHERE WALL THICKNESS EXCEEDS 12", PROVIDE ONE ADDITIONAL ANGLE FOR EACH ADDITION OF 4" OF WALL. 8. THIN FILM INTUMESCENT FIRE-RESISTIVE MATERIAL SHALL BE APPLIED TO ALL SURFACES OF THIN FILM INTUMESCENT FIRE-RESISTIVE MATERIAL SHALL BE APPLIED TO ALL SURFACES OF INTERIOR LINTELS AT OPENINGS EXCEEDING 4'-0"; SEE SPECIFICATION SECTION 07 81 23.
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
FEMALE
LOCKER
G605
MALE
LOCKER
G603
FEMALE
TOILET
G383
STORAGE
G609G609
BREAK
AREA
G607
TOILET
G610
CORRIDOR
G245NG245N
LACTATION
ROOM
G383A
VENDING /
KITCHENETTE
G608
CORRIDOR
0241N
PB
PB
TOILET
G611
KS
KS
CLOSET
OSOS
OS
OS
OS
OS
BUILDING 1
S
S S
S S
S
S
S S
S
S
S S
S
S S S S
S
S
S
SS
S
S
S
S S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S
S S
S S
S S
S S
S S
S S
OSOS
OS
OS
OS
OS
OS
OS
OS OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
C8
B-AE502
G607
9'-0"
G608G608
9'-0"
7'-2"
G609
9'-0"
G383G383
9'-0"
EQ
6'-
0" 6'-
0"
EQ
9'-2" 8'-0" EQ EQ
EQ
6'-
0" 6'-
0"
EQ
8'-6" 8'-6" 4'-0"
TYP
B2
B-AE502
B-AE502
C8
B-AE502
C8
6'-4 1/2"
EQ
EQ
EXP
10'-0" 10'-0" 10'-0" 1'-10"
G605
8'-6"
G603
8'-6"
EQ EQ
G610
9'-0"
G611
9'-0"
ALIGN
C8
B-AE502
C8
B-AE502
2'- 6"
6'- 0"
6'- 0"
EQ EQ
EQ
EQ
EQ EQ
G383A
9'-0"
7'-5 12"
7'-5 12"
7'-5 12"
1'-8"
+/-1'-9 1/2"
B2
B-AE502
SIM
B2
B-AE502
SIM
ALIGN
7'-8 12"
7'-10"
E1
B-AE504
4'-0"
6'-3"
1914 21
1312 1615
O
N
Q
J
F
G
L
U
T
U
REFLECTED CEILING NOTES:
1. REVIEW PROJECT GENERAL NOTES ON SHEET B-AE002 PRIOR TO START OF WORK.
2. CENTER GRID IN ROOM, IN BOTH DIRECTIONS, UNLESS OTHERWISE NOTED.
3. REFER TO HVAC, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL CEILING DEVICE INFORMATION. BRING CONFLICTS TO ATTENTION OF THE
A/E FOR FINAL COORDINATION AND RESOLUTION.
4. CENTER ALL CEILING FIXTURES, ACCESSORIES AND SPRINKLER HEADS WITHIN ACOUSTICAL CEILING TILE, UNLESS OTHERWISE NOTED.
5. IN GYPSUM BOARD CEILING CONSTRUCTION, ALIGN ALL CEILING FIXTURES, ACCESSORIES AND SPRINKLER HEADS WITH ADJACENT FIXTURES, UNLESS OTHERWISE NOTED. BRING ALL CONFLICTS TO ATTENTION OF A/E FOR FINAL COORDINATION AND RESOLUTION.
6. WHERE PLANS OR RCP CALLS FOR EXPOSED CEILINGS, CONTRACTOR SHALL CLEAN AND PREPARE THE UNDERSIDE OF THE EXISTING STRUCTURE
FOR NEW FINISHES PER DRAWINGS AND SPECIFICATIONS.
7. SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS BUILDABLE AS SHOWN.REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DRAWINGS AND SPECIFICATIONS FOR THE DESIGN OF EACH SYSTEMS (DUCT SIZE, CIRCUITING, ETC.). DEVICES LOCATIONS SHALL BE AS SHOWN ON THE ARCHITECTURAL RCP's. IN CASES WHERE CONFLICTS ARISE BETWEEN THE LIGHTING AND OTHER CEILING DEVICES, CONTRACTOR SHALL OBTAIN WRITTEN
CLARIFICATION FROM THE A/E PRIOR TO START OF WORK IN QUESTION AND RELATED WORK.
8. LOCATE LIGHT SWITCHES 44 IN. (CL) ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED.
9. CEILING TILE/GRID/HANGERS ARE NOT DESIGNED TO SUPPORT THE WEIGHT OF ADDITIONAL EQUIPMENT OR MATERIALS. SUPPORT CABLE, CONDUIT, FIXTURES, ETC. INDEPENDENTLY FROM THE STRUCTURE.
11. COORDINATE PLACEMENT OF REQUIRED WALL OR CEILING ACCESS PANELS WITH MEP EQUIPMENT REQUIRING ACCESS; A/E TO REVIEW PRIOR TO FRAMING. IMMEDIATELY ALERT A/E TO ACCESS PANELS REQUIRED BUT NOT INDICATED ON THE RCP.
12. LOCATE NEW SPRINKLER HEADS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13, INTERNATIONAL PLUMBING CODE (IPC) AND OTHER
APPLICABLE CODES.
13. SPRINKLER HEADS SHOWN ON THE ARCHITECTURAL RCP INDICATE HEAD LOCATIONS IN AREAS WHERE COORDINATION WITH ARCHITECTURAL DETAILS IS CRITICAL. CODE COMPLIANCE AND SPECIFIED COVERAGE MUST BE MAINTAINED. REFER TO FIRE PROTECTION DRAWINGS FOR REQUIRED SPRINKLER HEAD COVERAGE AND ADDITIONAL INFORMATION. IN LOCATIONS WHERE THE FIRE PROTECTION AND ARCHITECTURAL DRAWINGS ARE IN CONFLICT, CONTRACTOR SHALL OBTAIN WRITTEN CLARIFICATION FROM THE A/E PRIOR TO START OF WORK.
14. SPRINKLER CONTRACTOR SHALL VERIFY ALL COVERAGE OF NEW AND EXISTING (IF ANY) SPRINKLER HEADS. IF CODE CALLS FOR ADDITIONAL HEADS OR RELOCATION OF HEADS, CONTRACTOR TO INCLUDE THE COST FOR THIS WORK IN HIS BASE CONTRACT WORK PROPOSAL. CONTRACTOR SHALL FURNISH A/E WITH STAMPED SPRINKLER DRAWINGS PRIOR TO INSTALLATION OF SPRINKLER SYSTEM.
15. SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY A/E. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF
LIGHTING LAYOUT AND WITH OTHER CEILING COMPONENTS.
10. ACCESS PANELS ARE REQUIRED TO BE PROVIDED AS PART OF THE BASE CONTRACT WORK AT ALL GWB CEILINGS WHERE ACCESS TO NEW AND EXISTING FIRE ALARM ELECTRICAL JUNCTION BOXES / DEVICES AND MEP/ FIRE PROTECTION SYSTEM EQUIPMENT REQUIRING MAINTENANCE AND ACCESS.
COORDINATE FINAL MEP AND FIRE PROTECTION SHOP DRAWINGS WITH ACCESS DOOR LOCATIONS..
16. AT CORRIDORS AND ROOMS WITHOUT CEILINGS, OVERHEAD M,E,P SYSTEMS SHALL BE INSTALLED AT A MINIMUM OF 8'-0" CLEAR
OS
ACOUSTICAL TILE CEILING (24X24)
GYPSUM CEILING
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
CEILING MOUNTED LOW VOLTAGE
OCCUPANCY SENSOR
RECESSED 1' X 4' LIGHT FIXTURE
ACCESS DOORS - COORDINATE EXACT
LOCATIONS WITH DIVISION 23; FIELD
COORDINATE LOCATIONS
SECURITY CAMERA (BY VA)
REFLECTED CEILING SYMBOLS
RECESSED 2' X 4' LIGHT FIXTURE
101101
9'-0"
ROOM NUMBER AND CEILING HEIGHT
PENDANT LINEAR LIGHT FIXTURE
CEILING MOUNTED RECESSED
WALLWASHER LIGHTING FIXTURE
EXIT LIGHT OUTLET WITH FIXTURE - SHADING INDICATES
LOCATION OF FACE(S). ARROWS INDICATE DIRECTIONAL
ARROWS WHERE REQUIRED. WALL MOUNTED SIGNS AT +
90" CENTERED ABOVE DOOR WHERE APPLICABLE
WALL MOUNTED LINEAR LIGHTING FIXTURE
RECESSED LINEAR LIGHTING FIXTURE -
LENGTH AS SHOWN ON THE PLANS
PENDANT INDUSTRIAL LIGHT FIXTURE
CEILING MOUNTED RECESSED DOWNLIGHT
RECESSED 2' X 2' LIGHT FIXTURE
PENDANT SPRINKLER
UPRIGHT SPRINKLER
S
R
AC
U-3
S
M
E
C
H
A
N
I
C
A
L
R
O
O
M G
H
I
F
E
2'-6"
8"
M
E
C
H
A
N
I
C
A
L
R
O
O
M G
I
H
A
D
H
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh 1, 2 and 6
Key Plan
Balance of Work
9/12/2022
B-AE801
PARTIAL GROUND FLOOR
REFLECTED CEILING PLAN
DZ JH / DZ
SCALE: 1/8" = 1'-0"
8'4'0 16'
PARTIAL GROUND REFLECTED CEILING PLAN
F1
PLAN
NORTH
1 EXISTING LIGHT FIXTURE TO BE RE-INSTALLED.
2 REFER B1/B-AE502 FOR CEILING-HUNG TOILET PARTITION DETAIL.
PATCH AND REPAIR / EXTEND EXISTING GWB CEILING AS REQUIRED DUE TO ADJACENT CONSTRUCTION OR DEMOLITION WORK.
PROVIDE ACCESS PANEL SIZED FOR TRAP PRIMER MAINTENANCE / VALVES ABOVE GWB CEILING. COORDINATE FINAL LOCATION WITH PLUMBING.
EXTEND EXISTING ACT ASSEMBLY AS REQUIRED DUE TO ADJACENT CONSTRUCTION OR DEMOLITION WORK. REPLACE CUT GRID ASSEMBLY ASSEMBLIES WITH "NEW".
EXTEND EXISTING GWB CEILING / SUSPENSION ASSEMBLY AT SAME ELEVATION AS EXISTING INTO THE "NEW" CONSTRUCTION / CEILING AREA.6
ELECTRICAL PULL BOX; PAINT ALL EXPOSED SURFACES P-1 SEMI-GLOSS (GLOSS LEVEL 5). SEE ELECTRICAL FOR LABELING REQUIREMENTS.8
CAREFULLY REMOVE / SALVAGE / AND PROTECTIVELY STORE FOR RE-USE THE EXISTING ACOUSTICAL CEILING TILES AND SUSPENSION GRID SYSTEM AS REQUIRED TO INSTALL THE SPRINKLER SYSTEM TIE-IN / MODIFICATIONS. SEE B-FX110 FOR SPRINKLER PIPE ROUTING. REMOVAL OF ACT ASSEMBLY IS REQUIRED TO BE CONDUCTED AFTER-HOURS TO AVOID CONFLICT WITH VAMC OPERATIONS. COORDINATE / SCHEDULE DEMOLITION ACTIVITIES AND ACCESS WITH VA CFM OFFICE TWO WEEKS (MIN.) IN ADVANCE OF WORK. AREA OF WORK SHALL BE CLEANED UP AND READY FOR VAMC OPERATIONS BY THE NEXT BUSINESS DAY. DAMAGED ACT AND SUSPENSION GRID AS A RESULT OF WORK ACTIVITIES SHALL BE REPLACED WITH NEW COMPONENTS TO MATCH EXISTING
NEW LIGHT FIXTURE TO MATCH EXISTING ON INDEPENDENT SUPPORT ASSEMBLIES FROM DECK ABOVE. COORDINATE WITH ELECTRICAL DRAWINGS.10
KEYNOTES#
(SPECIFIC TO THIS
DRAWING ONLY)
SCALE: 1/8" = 1'-0"
8'4'0 16'
PARTIAL GROUND FLOOR REFLECTED CEILING PLAN
D5
SCALE: 1/8" = 1'-0"
8'4'0 16'
PARTIAL GROUND FLOOR REFLECTED CEILING PLAN
F5
PLAN
NORTH
PLAN
NORTH
RE-INSTALL SALVAGED LIGHT FIXTURE ON "NEW" SUPPORT ASSEMBLIES FROM DECK ABOVE. COORDINATE WITH ELECTRICAL DRAWINGS
EXISTING FIXTURE TO BE DEMO'ED. SEE DETAIL F6 / B-AD101 AND ELECTRICAL DRAWINGS FOR REQUIREMENTS.12 PROVIDE ACCESS PANEL SIZED FOR VALVE(S) ACCESS ABOVE GWB CEILING. COORDINATE FINAL LOCATION WITH PLUMBING.13
EXISTING FIXTURE TO BE SALVAGED; SEE DEMOLITION PLAN DETAIL F6 / B-AD101 AND ELECTRICAL DRAWINGS FOR REQUIREMENTS.
AutoCAD SHX Text
ELEC
AutoCAD SHX Text G616
AutoCAD SHX Text
TELEPHONE EQUIPMENT
AutoCAD SHX Text G116W
AutoCAD SHX Text
MECHANICAL RM
AutoCAD SHX Text G500A
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 121W
AutoCAD SHX Text G119W
AutoCAD SHX Text
G122WA
AutoCAD SHX Text G129W
AutoCAD SHX Text
ENGINEERING STORAGE
AutoCAD SHX Text G133W
AutoCAD SHX Text
FD
AutoCAD SHX Text G116
AutoCAD SHX Text
CORR.
AutoCAD SHX Text 143C
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text G130W
AutoCAD SHX Text
LAUNDRY CHUTE
AutoCAD SHX Text G144W
AutoCAD SHX Text
MAIL / COPY
AutoCAD SHX Text G140W
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 1-4
AutoCAD SHX Text
KITCHENETTE
AutoCAD SHX Text 0142C
AutoCAD SHX Text
CLOTHING STORAGE
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
CAB
AutoCAD SHX Text G001W
AutoCAD SHX Text
MALE TOILET
AutoCAD SHX Text G382
AutoCAD SHX Text
SHAFT
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
ELEV LOBBY
AutoCAD SHX Text G001
AutoCAD SHX Text
WASHER DRYER
AutoCAD SHX Text G003
AutoCAD SHX Text
CLOSET
AutoCAD SHX Text G004
AutoCAD SHX Text
FEMALE TOILET
AutoCAD SHX Text G606
AutoCAD SHX Text
MALE TOILET
AutoCAD SHX Text G604
AutoCAD SHX Text
PE #1
AutoCAD SHX Text
PE #2
AutoCAD SHX Text
PE #3
AutoCAD SHX Text
PE #4
AutoCAD SHX Text
PE #5
AutoCAD SHX Text
PE #6
AutoCAD SHX Text
PE #7
AutoCAD SHX Text
PE #8
AutoCAD SHX Text
SE #12
AutoCAD SHX Text
SE #11
AutoCAD SHX Text
SE #10
AutoCAD SHX Text
SE #9
AutoCAD SHX Text
MECHANICAL RM
AutoCAD SHX Text G500A
AutoCAD SHX Text 4"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 6"
AutoCAD SHX Text
FSP
AutoCAD SHX Text
FSP
AutoCAD SHX Text
FSP
AutoCAD SHX Text
FSP
AutoCAD SHX Text
FSP
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text
SPR
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text 6"
AutoCAD SHX Text 2"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text
MATCHLINE, FOR CONTINUATION, SEE C-FX101
AutoCAD SHX Text
SPR
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
FUTURE SIM CENTER
AutoCAD SHX Text G614
AutoCAD SHX Text
UP
AutoCAD SHX Text
PLUMBING EQUIPMENT
AutoCAD SHX Text G955
AutoCAD SHX Text
TEL. RM.
AutoCAD SHX Text G632
AutoCAD SHX Text
ELEC. ROOM
AutoCAD SHX Text G630
AutoCAD SHX Text
IT (TR-C)
AutoCAD SHX Text G922
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 2 "
AutoCAD SHX Text 2"
AutoCAD SHX Text
BD
AutoCAD SHX Text 2"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text
UP
AutoCAD SHX Text
BUILDING SUPPORT
AutoCAD SHX Text G953
AutoCAD SHX Text
STAIR
AutoCAD SHX Text 6-2
AutoCAD SHX Text
AREAWAY (E)
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text E
AutoCAD SHX Text 4"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 2 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text 1"
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text D
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
14B 15B 16B 17B 18B 19B 20B 21B 22B 23B
L1
M1
N1
O1
P1
Q1
OS
OS
OS
OS
OS
OS
OS
G010AG010A
9'-0"
G011G011
9'-0"
G012G012
9'-0"
4'- 0"
2'-
0" EQEQ
4'- 0"
2'-
0"EQEQ
7'-2"
9'-0" 9'-0"
REFLECTED CEILING NOTES:
1. REVIEW PROJECT GENERAL NOTES ON SHEET B-AE002 PRIOR TO START OF WORK.
2. CENTER GRID IN ROOM, IN BOTH DIRECTIONS, UNLESS OTHERWISE NOTED.
3. REFER TO HVAC, ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL CEILING DEVICE INFORMATION. BRING CONFLICTS TO ATTENTION OF THE
A/E FOR FINAL COORDINATION AND RESOLUTION.
4. CENTER ALL CEILING FIXTURES, ACCESSORIES AND SPRINKLER HEADS WITHIN ACOUSTICAL CEILING TILE, UNLESS OTHERWISE NOTED.
5. IN GYPSUM BOARD CEILING CONSTRUCTION, ALIGN ALL CEILING FIXTURES, ACCESSORIES AND SPRINKLER HEADS WITH ADJACENT FIXTURES, UNLESS OTHERWISE NOTED. BRING ALL CONFLICTS TO ATTENTION OF A/E FOR FINAL COORDINATION AND RESOLUTION.
6. WHERE PLANS OR RCP CALLS FOR EXPOSED CEILINGS, CONTRACTOR SHALL CLEAN AND PREPARE THE UNDERSIDE OF THE EXISTING STRUCTURE
FOR NEW FINISHES PER DRAWINGS AND SPECIFICATIONS.
7. SURVEY FIELD CONDITIONS AND VERIFY THAT WORK IS BUILDABLE AS SHOWN.REFER TO MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DRAWINGS AND SPECIFICATIONS FOR THE DESIGN OF EACH SYSTEMS (DUCT SIZE, CIRCUITING, ETC.). DEVICES LOCATIONS SHALL BE AS SHOWN ON THE ARCHITECTURAL RCP's. IN CASES WHERE CONFLICTS ARISE BETWEEN THE LIGHTING AND OTHER CEILING DEVICES, CONTRACTOR SHALL OBTAIN WRITTEN
CLARIFICATION FROM THE A/E PRIOR TO START OF WORK IN QUESTION AND RELATED WORK.
8. LOCATE LIGHT SWITCHES 44 IN. (CL) ABOVE FINISHED FLOOR, UNLESS OTHERWISE NOTED.
9. CEILING TILE/GRID/HANGERS ARE NOT DESIGNED TO SUPPORT THE WEIGHT OF ADDITIONAL EQUIPMENT OR MATERIALS. SUPPORT CABLE, CONDUIT, FIXTURES, ETC. INDEPENDENTLY FROM THE STRUCTURE.
11. COORDINATE PLACEMENT OF REQUIRED WALL OR CEILING ACCESS PANELS WITH MEP EQUIPMENT REQUIRING ACCESS; A/E TO REVIEW PRIOR TO FRAMING. IMMEDIATELY ALERT A/E TO ACCESS PANELS REQUIRED BUT NOT INDICATED ON THE RCP.
12. LOCATE NEW SPRINKLER HEADS IN ACCORDANCE WITH THE REQUIREMENTS OF NFPA 13, INTERNATIONAL PLUMBING CODE (IPC) AND OTHER
APPLICABLE CODES.
13. SPRINKLER HEADS SHOWN ON THE ARCHITECTURAL RCP INDICATE HEAD LOCATIONS IN AREAS WHERE COORDINATION WITH ARCHITECTURAL DETAILS IS CRITICAL. CODE COMPLIANCE AND SPECIFIED COVERAGE MUST BE MAINTAINED. REFER TO FIRE PROTECTION DRAWINGS FOR REQUIRED SPRINKLER HEAD COVERAGE AND ADDITIONAL INFORMATION. IN LOCATIONS WHERE THE FIRE PROTECTION AND ARCHITECTURAL DRAWINGS ARE IN CONFLICT, CONTRACTOR SHALL OBTAIN WRITTEN CLARIFICATION FROM THE A/E PRIOR TO START OF WORK.
14. SPRINKLER CONTRACTOR SHALL VERIFY ALL COVERAGE OF NEW AND EXISTING (IF ANY) SPRINKLER HEADS. IF CODE CALLS FOR ADDITIONAL HEADS OR RELOCATION OF HEADS, CONTRACTOR TO INCLUDE THE COST FOR THIS WORK IN HIS BASE CONTRACT WORK PROPOSAL. CONTRACTOR SHALL FURNISH A/E WITH STAMPED SPRINKLER DRAWINGS PRIOR TO INSTALLATION OF SPRINKLER SYSTEM.
15. SUBMIT FIRE SPRINKLER LAYOUT FOR COORDINATION/APPROVAL BY A/E. PATTERN OF SPRINKLER LAYOUT SHALL COORDINATE WITH PATTERN OF
LIGHTING LAYOUT AND WITH OTHER CEILING COMPONENTS.
10. ACCESS PANELS ARE REQUIRED TO BE PROVIDED AS PART OF THE BASE CONTRACT WORK AT ALL GWB CEILINGS WHERE ACCESS TO NEW AND EXISTING FIRE ALARM ELECTRICAL JUNCTION BOXES / DEVICES AND MEP/ FIRE PROTECTION SYSTEM EQUIPMENT REQUIRING MAINTENANCE AND ACCESS.
COORDINATE FINAL MEP AND FIRE PROTECTION SHOP DRAWINGS WITH ACCESS DOOR LOCATIONS..
16. AT CORRIDORS AND ROOMS WITHOUT CEILINGS, OVERHEAD M,E,P SYSTEMS SHALL BE INSTALLED AT A MINIMUM OF 8'-0" CLEAR
OS
ACOUSTICAL TILE CEILING (24X24)
GYPSUM CEILING
HVAC SUPPLY DIFFUSER
HVAC RETURN DIFFUSER
SEMI-RECESSED SPRINKLER
CEILING MOUNTED LOW VOLTAGE
OCCUPANCY SENSOR
RECESSED 1' X 4' LIGHT FIXTURE
ACCESS DOORS - COORDINATE EXACT
LOCATIONS WITH DIVISION 23; FIELD
COORDINATE LOCATIONS
SECURITY CAMERA (BY VA)
REFLECTED CEILING SYMBOLS
UPRIGHT SPRINKLER
RECESSED 2' X 4' LIGHT FIXTURE
101101
9'-0"
ROOM NUMBER AND CEILING HEIGHT
PENDANT LINEAR LIGHT FIXTURE
CEILING MOUNTED RECESSED
WALLWASHER LIGHTING FIXTURE
EXIT LIGHT OUTLET WITH FIXTURE - SHADING INDICATES
LOCATION OF FACE(S). ARROWS INDICATE DIRECTIONAL
ARROWS WHERE REQUIRED. WALL MOUNTED SIGNS AT +
90" CENTERED ABOVE DOOR WHERE APPLICABLE
WALL MOUNTED LINEAR LIGHTING FIXTURE
RECESSED LINEAR LIGHTING FIXTURE -
LENGTH AS SHOWN ON THE PLANS
PENDANT INDUSTRIAL LIGHT FIXTURE
CEILING MOUNTED RECESSED DOWNLIGHT
RECESSED 2' X 2' LIGHT FIXTURE
VRF CASSETTE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA NY Manhattan Campus
423 E 23RD Street, New York, NY 10010
630-600A
Project Director
Revisions: Date:
A/E:
AECOM
3101 WILSON BLVD, SUITE 900
ARLINGTON, VA. 22201
703-682-4900
WWW.AECOM.COM
Construction Document Refresh 1, 2 and 6
Key Plan
Balance of Work
9/12/2022
B-AE803
BUILDING 2 PARTIAL GROUND
FLOOR REFLECTED CEILING PLAN
DZ JH / DZ
SCALE: 1/8" = 1'-0"
8'4'0 16'
PARTIAL GROUND REFLECTED CEILING PLAN
F1
PLAN
NORTH
KEYNOTES#
(SPECIFIC TO THIS
DRAWING ONLY)
RE-INSTALL EGGCRATE CEILING ASSEMBLY TO LIKE NEW CONDITION AT AREAS REMOVED FOR NEW DUCTWORK / VRF SYSTEM INSTALLATION. DAMAGED CEILING COMPONENTS AS A RESULT OF CONSTRUCTION ACTIVITIES SHALL BE REPLACED TO MATCH EXISTING.
PATCH AND REPAIR / RE-INSTALL MOISTURE RESISTANT GWB CEILING ASSEMBLY, LIGHTS, ACCESS DOORS AS REQUIRED AT AREA REMOVED FOR THE NEW DUCTWORK /
VRF SYSTEM INSTALLATION. PAINT P-1.
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text G015
AutoCAD SHX Text
CARPENTRY SHOP
AutoCAD SHX Text G013A
AutoCAD SHX Text
PLUMBING STORAGE
AutoCAD SHX Text
TRANSPORTATION
AutoCAD SHX Text G008S
AutoCAD SHX Text
OXYGEN
AutoCAD SHX Text
TANK
AutoCAD SHX Text
STAIR #2
AutoCAD SHX Text
LOCKER RM
AutoCAD SHX Text G010A
AutoCAD SHX Text
TOILET
AutoCAD SHX Text G011
AutoCAD SHX Text
TOILET
AutoCAD SHX Text G012
AutoCAD SHX Text
BREAK RM
AutoCAD SHX Text G010
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
MACH
AutoCAD SHX Text
ELEV
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text G013B
AutoCAD SHX Text
SPRINKLER
AutoCAD SHX Text
VALVES
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text G015A
AutoCAD SHX Text
UP
AutoCAD SHX Text
SRC
AutoCAD SHX Text
BF1
AutoCAD SHX Text
BF2
AutoCAD SHX Text M1
AutoCAD SHX Text M2
AutoCAD SHX Text F I R S T A V E N U E
AutoCAD SHX Text A S S E R L E V Y P L A C E
AutoCAD SHX Text E A S T 2 3 r d. S T R E E T
AutoCAD SHX Text
BLDG 3
AutoCAD SHX Text
BLDG 2
AutoCAD SHX Text
BLDG 4 / 5
AutoCAD SHX Text
E A S T 25 TH STREET
AutoCAD SHX Text
BLDG 1
AutoCAD SHX Text N
G605
MALE
LOCKER
G603
FEMALE
TOILET
G383
STORAGE
G609G609
BREAK
AREA
G607
TOILET
G610
CORRIDOR
G245NG245N
LACTATION
ROOM
G383A
S S
S
S S
S S
S
S
S S
S
S
S
S S S S
S
S
S
SS
S
SSS
S
S
S S
S
S
S S
S
S
S
S
S
S S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
VENDING /
KITCHENETTE
G608
CORRIDOR
0241N
S
S
S
S
S S S
S
S
PB
PB
TOILET
G611
KS
KS
S S
S S
S S
S S
S S
S S
S S
S
CLOSET
E6
B-AE501
E6
B-AE501
E6
B-AE501
CT-1
LK-1
LK-1LK-1
P-2
P-5
LK-1
LK-1
P-2
VP
-3
D9
B-AE501
3 CT-1
VP-3
4 54 5
E6
B-AE501
4 5
D9
B-AE501
4 5
E7
B-AE501
CG-2
CG-2
CG-2
CG-2
CG-2
CG-2 CG-2 CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
4 5
CG-2
RES 5-2
RES 5-2
CG-2 CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
CG-2
22 23
BUILDING 1
S S
S
S S
S S
S
S
S S
S
S
S S
S
S S S S
S
S
S
SS
S
SSS
S
S
S S
S
S S
S
S
S
S
S S
S
S
S
S
S
S
S
S
S
S
S
S
S
S S S
S
S
S S
S S
S S
S S
S S
S S
FINISH NOTES:
1. FINISH PLANS ARE TO DENOTE LOCATIONS WHERE CHANGE IN FINISH / MULTIPLE FINISHES OCCUR. REFER TO B-AF602 FOR COMPLETE SCHEDULE ON FINISHES
AND COLORS.
2. REFER TO SHEET AE001 FOR TYPICAL PLAN LEGENDS AND SYMBOLS .
3. REFER TO SHEET B-AE002 FOR GENERAL NOTES.
4. MANUFACTURER’S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS. PRODUCTS OF OTHER MANUFACTURER’S EQUIVALENT TO COLORS, FINISHES, TEXTURES AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS WILL BE ACCEPTABLE UPON APPROVAL IN WRITING BY VA CFM OFFICE / A/E FOR FINISH REQUIREMENTS.
5. DRAWINGS AND SPECIFICATIONS ARE COMPLIMENTARY COMPONENTS OF THE CONTRACT DOCUMENTS, REVIEW ALL DRAWINGS AND SPECIFICATIONS FOR THE COMPLETE SCOPE OF WORK. NOTIFY ARCHITECT IMMEDIATELY FOR CLARIFICATION IF INCONSISTENCIES, CONTRADICTIONS OR OMISSIONS ARE DISCOVERED.
6. ALL MATERIALS AND SYSTEMS SHALL BE INSTALLED AS PER MANUFACTURE’S SPECIFICATIONS AND ALL CONSTRUCTION SHALL BE INDUSTRY STANDARD OR
BETTER.
7. ONLY NEW ITEMS OF RECENT MANUFACTURING AND FREE OF DEFECTS SHALL BE PERMITTED IN THE WORK UNLESS OTHERWISE NOTED. REJECTED ITEMS SHALL BE REMOVED IMMEDIATELY FROM THE WORK AND REPLACED WITH ITEMS OF QUALITY SPECIFIED AT NO COST TO THE GOVERNMENT.
8. WHERE ITEMS OF SURFACES ARE NOT SPECIFICALLY MENTIONED, PAINT THE SAME AS SIMILAR ADJACENT MATERIALS OR AREA. IF COLOR OR FINISH IS NOT
DESIGNATED, ARCHITECT WILL SELECT FROM STANDARD COLORS OR FINISHES AVAILABLE.
9. PAINT ALL WALLS AND GWB CEILINGS P-1, UON. ALL METAL DOORS AND WINDOW FRAMES SHALL PAINTED TO MATCH ADJACENT WALL FINISH, UON. REFER TO
SHEET B-AE602 FOR EXCEPTIONS.
10. DO NOT INCLUDE PAINTING WHEN FACTORY-FINISHING OR INSTALLER FINISHING IS SPECIFIED FOR SUCH ITEMS AS, BUT NOT LIMITED TO, METAL TOILET ENCLOSURES, PRE-FINISHED PARTITION SYSTEMS, ACOUSTICAL MATERIALS, ARCHITECTURAL WOODWORK AND CASEWORK, STAINLESS STEEL ELEVATOR ENTRANCE DOORS AND FRAMES, LIGHT FIXTURES, SWITCHGEAR AND DISTRIBUTION CABINETS. GRILLES, WALL / CEILING DIFFUSERS, ELECTRICAL PANELS, ACCESS PANELS, ETC. WHICH ARE EXPOSED IN FINISH SPACES SHALL BE PAINTED IN SEMI-GLOSS (GLOSS LEVEL 5) PAINT TO MATCH THE SURFACE ON WHICH THEY OCCUR.
11. REFER TO B-AE800 SERIES DRAWINGS FOR CEILING FINISH DISTRIBUTION AND CEILING HEIGHTS.
12. REFER TO B-AF601 AND B-AE 100 SERIES DRAWINGS FOR EXTENT OF WALL PROTECTION.
13. WHERE EXPOSED CEILING IS INDICATED, PAINT OVERHEAD EXPOSED STRUCTURE, PIPING, DUCT WORK, AND OTHER CEILING ELEMENTS NOT PROHIBITED BY CODE, P-2, UON. PROTECT SPRINKLERS PRIOR TO PAINTING. REFER TO SPECIFICATIONS FOR INFORMATION REGARDING PAINTING OF MECHANICAL, ELECTRICAL, AND FIRE PROTECTION EQUIPMENT. REFER TO IDENTITY SCHEDULE IN SPECIFICATION SECTION 09 91 00 "PAINTING" FOR LABELING.
14. FLOORING FINISHES TO RUN UNDER ALL MILLWORK, EQUIPMENT, LOCKERS AND RAISED MECHANICAL / EQUIPMENT PLATFORMS.
15. REFER TO B-AI201 FOR TYPICAL MOUNTING HEIGHTS.
16. ALL NEW AND EXISTING HOUSEKEEPING PADS WITHIN THE PROJECT LIMITS TO BE PAINTED P-7 (FEDERAL SAFETY YELLOW).
FINISH PATTERN LEGEND:
1914 21
1312 1615
O
N
Q
J
F
G
L
S
U
T
U
CT-1
RES 5-2
M
E
C
H
A
N
I
C
A
L
R
O
O
M G
E
Q
E
Q
E
Q
E
Q
E
Q
E
Q
M
E
C
H
A
N
I
C
A
L
R
O
O
M G
E
Q
E
Q
E
Q
E
Q
E
Q
E
Q
I
H
A
F
E
D
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
F i l e
P a t h
P
M
ISSUED FOR
CONSTRUCTION
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
321 4 5 6 7 8 9 10
VA…
This is the start of the file's text. The full file is on GovTribe.