This is a business case and solicitation document for the Kenton County Airport Board's Concourse A Ramp Level Office Upgrades project at Cincinnati/Northern Kentucky International Airport. The project encompasses the renovation of approximately 20,000 square feet of semi-occupied space on the ramp level of Concourse A to address four primary needs: establishing a permanent Emergency Operations Center (EOC) to replace a demolished training facility location; creating a new conference room for the SAMS department displaced by the interim EOC; relocating and upgrading Environmental Services offices; and upgrading common areas including entrances, lobbies, restrooms, and newly constructed changing rooms. The scope of work includes casework and partition demolition, wall and door framing, finish upgrades (paint, carpet, ceiling tiles), LED lighting upgrades, mechanical/electrical/plumbing (MEP) upgrades to accommodate occupancy loads, data infrastructure, and security access systems. A mandatory pre-bid meeting and site visit are scheduled for Wednesday, April 1, 2026 at 10:00 am at CVG Airport's Main Terminal Ticketing area. Written questions must be submitted by 11:59 pm on Friday, April 17, 2026, with responses posted by Tuesday, April 21, 2026. Sealed bids must be received electronically no later than 2:00 pm Eastern Time on Thursday, April 30, 2026, with contract award anticipated for May 26, 2026. The contract term is 212 calendar days with a requirement to commence work within 10 days of receiving the Notice to Proceed.
The estimated total project cost is $951,000.00, comprising design fees of $63,000.00, construction and installation costs of $790,000.00, contingency of $79,000.00 (minimum 10 percent), force labor of $15,000.00, and miscellaneous costs of $4,000.00. This is a federally-funded project under the Airport Improvement Program subject to Buy American Act compliance for steel and manufactured goods. Bidders must provide a proposal bond equal to 5 percent of the bid amount and furnish performance and payment bonds each at 100 percent of the contract price upon award. General contractors must demonstrate specific qualifications including airport Security Identification Display Area (SIDA) experience within the past five years with active airfield operations, eligibility for airport badging, and compliance with FAA, TSA, and airport security requirements. All project personnel require airport identification badges at $44.00 per badge, and a $500.00 key deposit is required. Liquidated damages are assessed at $500.00 per day for contract delays. The project requires phased construction to maintain operational continuity while approximately 50 percent of the space remains occupied. Mobilization is capped at 10 percent of total project cost, with payment released in phases based on progress inspections and completion milestones. Bidders must comply with federal civil rights requirements including Title VI of the Civil Rights Act of 1964 and Equal Employment Opportunity provisions, and the procurement encourages disadvantaged business enterprise participation.
View the file
Other files
Show all 29
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Concourse A Ramp Level Upgrade
Current Situation/Background Information
The identified Concourse A, ramp level space, is semi-occupied, and utilized by multiple departments. The goal of this project is to concert the needs into a singular upgrade. The four needs are:
1. EOC
-- The catalyst for upgrading this area was identifying a space for an interim EOC, because the previous location (ARFF Training Facility) was demolished.
2. Concourse A Conference Room (SAMS Area)
-- The original SAMS Area was displaced by a make-shift EOC. Upgrading this space will allow for a new conference space to be utilized by SAMS, C&BD, and other meetings.
3. Relocate Environmental Services
-- In the general vicinity, Housekeeping is returning to their previous location. Additionally, vacant rooms on the perimeter require an upgrade to support the increased occupancy and utilization of staff.
4. Common Areas Finish Upgrades
-- Common spaces in the area (offices, entrances, restrooms, breakroom, etc.) require an upgrade for uniformity and function to support the various uses.
Project Definition
Utilize idle space at Concourse A Ramp Level to address the needs of the following four efforts.
1. EOC Area: Formally upgrade the make-shift EOC and support offices
-- The scope involves casework demo; demising partition walls and doors to accommodate security and egress; finishes upgrades (paint, carpet, ceiling pads, etc.);
LED lighting upgrades; MEP upgrades to accommodate occupancy loads; data upgrades; security access systems.
2. Conference Room (SAMS Area): Modify space to accommodate a new conference room displaced by the EOC.
-- The scope involves casework and partition demo; finish upgrades (paint, carpet, ceiling pads, etc.); LED lighting upgrades; required MEP upgrades to accommodate occupancy loads; and data upgrades.
3. Relocate Environmental Services: Upgrade offices for the return of Environmental Services.
-- The scope involves finish upgrades (paint, carpet, ceiling patch.); LED lighting upgrades; data upgrades.
4. Common Areas Upgrade: Upgrade common space (Entrances, lobby, restrooms, and create new changing rooms).
-- The scope involves new finishes in existing common space. Miscellaneous demo of existing casework; constructing new partitions and openings to provide new changing rooms; finish upgrades (paint, carpet, ceiling pads, etc.); bathroom tile and grout cleaning; miscellaneous toilet partition and bathroom accessories replacements; reinstall new water fountains; existing bathroom fixture cleaning and valve replacements as required; LED lighting upgrades are required.
The business objectives: P&D has contracted with on-call designer (GRW), to provide: bid documents; construction estimate; and permit, for CVG to request GC bidders to commence with the work in Quarter 1, 2025. Upgrades will require construction while occupied, displacing some personnel into perimeter vacant rooms.
A four month construction project is expected.
Project Justification: Efficiently fulfill the needs of multiple departments as a single project utilizing vacant available space.
Project Approach
Step 1: Confirm the scope of the four efforts by sharing on-call designer's finished schedule
Step 2: Develop bid documents, construction estimate and obtain permit
Step 3: Solicit General Contractor (GC) bids to complete the project by Q3 2025
Alternatives
1. Do not upgrade the area and utilize as is with aged finishes and no MEP adjustments for the new use
2. Prioritize the four needs and move forward on one or two of the upgrade projects
3. Identify another location to fulfill the needs of the multiple departments
Recommendation
Advise the on-call to move forward with scope finalization, then create bid documents, obtain a construction estimate and acquire a permit. Finally, solicit bids from
GCs to complete the work by Q3 2025.
Cost
Design: $63,000.00
Construction/Installation: $790,000.00
Contingency (min 10%): $79,000.00
Force Labor: $15,000.00
Miscellaneous: $4,000.00
Total Cost: $951,000.00
Project Funding
CapEx
Project Schedule
Complete construction by Q3 2025
Strategic Plan Fit Sustainability FitMaster Plan Fit
Known Risks & Limitations
Current upgrades ROM pricing established prior to the development of design documents can misrepresent actual costs for development. Repurposing existing vacant space without design risks providing inadequate MEP and life safety requirements per code and occupancy changes. The existing space has varying degrees of improvements. Existing storage and old furnishings will need to be disposed of or relocated. Coordination and displacement of existing occupants will need to be managed during construction. Anticipate Construction Estimate by end of year.
Candace McGraw
Dil Gruffydd
Concurrence Leader, Adam Kressler
Executive Sponsor, Shannon Oldfield
Business Unit Leader, Bill Siemer
Sponsor/Originator, Damian Weller
Visuals
Shannon R. Oldfield (Jan 30, 2025 10:43 EST) Shannon R. Oldfield
Dilwyn Gruffydd (Feb 3, 2025 17:03 EST)
Candace McGraw (Feb 3, 2025 17:16 MST) Candace McGraw https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr https://cvgairport.na2.adobesign.com/verifier?tx=CBJCHBCAABAA361HO0d2i-u37JXhWssUj95ao0qrMSJr
CVG Concourse A Ramp Refresh, Prelim ROM Rev 1 12/18/2024
Units Unit Unit Cost Total
Demo 19752 SF 2 39504
Finishes Updates 19752 SF 18 355536
Fire Suppression relocate heads 5500 SF 3.5 19250
HVAC redistribution 5500 SF 4 22000
HVAC replace diffusers 19752 SF 1.5 29628
Lighting / Power / Data / Comm / Fire Alarm 19752 SF 9 177768
Add Walls 1160 SF 18 20880
Add Doors 9 EA 2500 22500
Subtotal 687066
Contingency 15% 103060
Total $790,126
Cost / SF 19752 SF $40
Proposed AE Fee SD, CD, CA $62,485
Rev 1 removed the following:
3941 SF of space not required for current program but may be needed in future.
3007 SF of space that has already had lighting and finishes updates.
GRW NO. 5035-09
ROOM FINISH SCHEDULE
ROOM IDENTIFICATION FLOOR WALLS CEILING
COMMENTSROOM
NUMBER ROOM NAME AREA (SF) FLOOR FINISH -
EXISTING
BASE
FINISH
BUILDING ORIENTATION INDICATES PLAN NORTH
CEILING
MATERIAL
CEILING
FINISH
CEILING
HEIGHT
(A.F.F.)
NORTH SOUTH EAST WEST
MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH
C100 VESTIBULE 47.65 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C101 RECEIVING 150.38 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C102 ELEVATOR EQUIPMENT 54.64 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C103 CORRIDOR 424.99 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C104 HOUSEKEEPING STORAGE 155.96 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C105 HOUSEKEEPING OFFICE 210.93 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C106 HOUSEKEEPING STORAGE 212.45 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C107 HOUSEKEEPING STORAGE 194.97 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C108 CUSTOMER SERVICE STORAGE 308.41 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C109 HOUSEKEEPING OFFICE 259.29 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C110 HOUSEKEEPING OFFICE 259.29 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C111 HOUSEKEEPING CONFERENCE 259.29 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C112 HOUSEKEEPING STORAGE 259.29 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C113 HOUSEKEEPING STORAGE 258.88 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C114 READY ROOM 90.63 NO WORK
C115 VACANT 860.79 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C116 VACANT 4,087.08 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C117 VACANT 502.04 CPT RB-1 CMU PT-1 GYP. BD PT-1 CMU PT-1 GYP. BD PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C118 VACANT 577.37 NO WORK
C119 PSA STORAGE 194.24 NO WORK
C120 VACANT 105.85 NO WORK
C121 VACANT 153.02 NO WORK
C122 VACANT 152.59 NO WORK
C123 CORRIDOR 612.84 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C124 VACANT 264.94 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C125 VACANT 506.62 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C126 VACANT 117.58 NO WORK
C127 VACANT 118.12 NO WORK
C128 VACANT 118.12 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C129 VACANT 118.12 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C130 CORRIDOR 171.4 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C131 VACANT 140.87 NO WORK
C132 VACANT 140.87 NO WORK
C133 CORRIDOR 542.08 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C134 VACANT 110.03 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C135 VACANT 109.81 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C136 VACANT 109.81 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C137 VACANT 104.31 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C138 VACANT 104.31 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C139 VACANT 107.61 OCCUPIED, NO WORK
C140 CORRIDOR 539.81 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C141 VACANT 334.57 OCCUPIED, NO WORK
C142 VACANT 165.97 OCCUPIED, NO WORK
C143 VACANT 359.32 OCCUPIED, NO WORK
C144 KCAB OPS DEPT. BREAKROOM 359.33 OCCUPIED, NO WORK
C145 KCAB OPS DEPT. 533.87 OCCUPIED, NO WORK
C146 KCAB OPS DEPT. 503.36 OCCUPIED, NO WORK
C147 KCAB EOC CENTER 787.65 CPT RB-1 VARIES PT-1 CMU PT-1 GYP. BD PT-1 GYP. BD PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C148 STORAGE 42.58 NO WORK
C149 CORRIDOR 210.38 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C150 MEN'S LOCKER ROOM 231.74 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C151 MEN'S RESTROOM 287.97 LVT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C152 ELEVATOR EQUIPMENT 52.42 NO WORK
C153 HOUSEKEEPING BREAKROOM 817.09 NO WORK
C154 CORRIDOR 199.95 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C155 WOMEN'S RESTROOM 635.13 LVT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CLEAN TILE, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C156 WOMEN'S LOCKER ROOM 229.52 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C157 HOUSEKEEPING OFFICE 175.75 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C158 HOUSEKEEPING OFFICE 176.09 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C159 READY ROOM 68.93 NO WORK
C160 FIRE PROTECTION 51.83 NO WORK
C161 JANITOR STORGE 196.85 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C162 CORRIDOR 918.58 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C163 ELECTRICAL 39.13 NO WORK
C164 ELEVATOR EQUIPMENT 161.81 NO WORK
C165 HOUSEKEEPING STORAGE 246.88 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C166 HOUSEKEEPING WOMEN'S LOCKER ROOM 283.11 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C167 HOUSEKEEPING MEN'S LOCKER ROOM 287.62 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C168 ELECTRICAL 92.11 NO WORK
D165 MECHANICAL 734.06 NO WORK
D166 CORRIDOR 173.28 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D167 VACANT 257.54 OCCUPIED, NO WORK
D168 VACANT 170.08 OCCUPIED, NO WORK
D169 READY ROOM 90.06 NO WORK
D170 VACANT 107.83 OCCUPIED, NO WORK
D171 VACANT 107.61 OCCUPIED, NO WORK
D172 CORRIDOR 95.43 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D173 VACANT 121.22 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D174 VACANT 120.83 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D175 STORAGE 46.02 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D176 VACANT 141.31 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
D177 VACANT 141.31 CPT RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP CARPET, PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C20 STAIR 202.36 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C21 STAIR 239.05 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C23 STAIR 317.62 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
C24 STAIR 319.8 CONC RB-1 CMU PT-1 CMU PT-1 CMU PT-1 CMU PT-1 SEE RCP PAINT, CEILING TILES, CLEAN GRID & CAULK CMU IF NEEDED
TOTAL AREA 25652.23
AutoCAD SHX Text
D3-IF33
AutoCAD SHX Text D3-1200
AutoCAD SHX Text D3-1010
AutoCAD SHX Text D3-1240
AutoCAD SHX Text D3-1220
AutoCAD SHX Text
D3-IF50A
AutoCAD SHX Text
D3-IF51
AutoCAD SHX Text
D3-IF55
AutoCAD SHX Text D3-1220A
AutoCAD SHX Text D3-1250
AutoCAD SHX Text F-121B
AutoCAD SHX Text
D3-IF36
AutoCAD SHX Text
D3-IF35
AutoCAD SHX Text
D3-IF50
AutoCAD SHX Text
D3-IF34
AutoCAD SHX Text
D3-IF32
AutoCAD SHX Text
D3-IF43
AutoCAD SHX Text
D3-IF42
AutoCAD SHX Text
D3-IF40A
AutoCAD SHX Text
D3-IF39A
AutoCAD SHX Text
D3-IF40C
AutoCAD SHX Text D3-I439B
AutoCAD SHX Text
D3-IF40B
AutoCAD SHX Text
D3-IF44
AutoCAD SHX Text
D3-IF45
AutoCAD SHX Text
D3-IF54
AutoCAD SHX Text
D3-IF49
AutoCAD SHX Text
D3-IF48
AutoCAD SHX Text
D3-IF47
AutoCAD SHX Text
D3-IF53
AutoCAD SHX Text
D3-IF46
AutoCAD SHX Text
D3-IF52
AutoCAD SHX Text
D3-IF63
AutoCAD SHX Text
D3-IF62
AutoCAD SHX Text
D3-IF61
AutoCAD SHX Text
D3-IF70
AutoCAD SHX Text
D3-IF69
AutoCAD SHX Text
D3-IF68
AutoCAD SHX Text
D3-IF67
AutoCAD SHX Text D3-1239
AutoCAD SHX Text
D3-IF66B
AutoCAD SHX Text
D3-IF66A
AutoCAD SHX Text
D3-IF65
AutoCAD SHX Text
D3-IF64
AutoCAD SHX Text D3-64A
AutoCAD SHX Text D3-64B
AutoCAD SHX Text
D3-IF64C
AutoCAD SHX Text F-135
AutoCAD SHX Text D2-1430
AutoCAD SHX Text D2-1420
AutoCAD SHX Text
D2-IF7B
AutoCAD SHX Text
D2-IF7A
AutoCAD SHX Text
D2-IF12
AutoCAD SHX Text
D2-IF13
AutoCAD SHX Text
D2-IF28
AutoCAD SHX Text D2-1300
AutoCAD SHX Text
D2-IF27
AutoCAD SHX Text D2-1454
AutoCAD SHX Text D2-1460
AutoCAD SHX Text D2-1451
AutoCAD SHX Text
D2-IF20
AutoCAD SHX Text
D2-IF19
AutoCAD SHX Text F-133
AutoCAD SHX Text F-101
AutoCAD SHX Text D2-1400
AutoCAD SHX Text D2-1410
AutoCAD SHX Text D2-1390
AutoCAD SHX Text
D2-IF16
AutoCAD SHX Text
IF-104
AutoCAD SHX Text
D2-IF17A
AutoCAD SHX Text
D2-IF17B
AutoCAD SHX Text
D2-IF11
AutoCAD SHX Text
D2-IF10
AutoCAD SHX Text
D2-IF09
AutoCAD SHX Text
D2-IF08
AutoCAD SHX Text
D2-IF06
AutoCAD SHX Text
D2-IF05
AutoCAD SHX Text
D2-IF04
AutoCAD SHX Text
D2-IF03
AutoCAD SHX Text A-34
AutoCAD SHX Text D2-1350
AutoCAD SHX Text D2-1360
AutoCAD SHX Text D2-1370
AutoCAD SHX Text D2-1381
AutoCAD SHX Text F-134A
AutoCAD SHX Text
D2-IF14
AutoCAD SHX Text
D2-IF15
AutoCAD SHX Text
D2-IF16A
AutoCAD SHX Text
D2-IF16B
AutoCAD SHX Text
D2-IF16C
AutoCAD SHX Text
D3-IF56
AutoCAD SHX Text
D3-IF57
AutoCAD SHX Text
D3-IF58
AutoCAD SHX Text
D3-IF59
AutoCAD SHX Text
D3-IF60
AutoCAD SHX Text
ELEVATOR ABOVE NO ACCESS
AutoCAD SHX Text
D2-IF18
AutoCAD SHX Text
RECEIVING
AutoCAD SHX Text C101
AutoCAD SHX Text
150.38 sf
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text C102
AutoCAD SHX Text
54.64 sf
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text C100
AutoCAD SHX Text
47.65 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C103
AutoCAD SHX Text
424.99 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C104
AutoCAD SHX Text
155.96 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C105
AutoCAD SHX Text
210.93 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C106
AutoCAD SHX Text
212.45 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C107
AutoCAD SHX Text
194.97 sf
AutoCAD SHX Text
CUSTOMER SERVICE
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C108
AutoCAD SHX Text
308.41 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C113
AutoCAD SHX Text
258.88 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C112
AutoCAD SHX Text
259.29 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
CONFERENCE
AutoCAD SHX Text C111
AutoCAD SHX Text
259.29 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C110
AutoCAD SHX Text
259.29 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C109
AutoCAD SHX Text
259.29 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C115
AutoCAD SHX Text
860.79 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C116
AutoCAD SHX Text 4,087.08 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C117
AutoCAD SHX Text
502.04 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C118
AutoCAD SHX Text
577.37 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C120
AutoCAD SHX Text
105.85 sf
AutoCAD SHX Text
PSA STORAGE
AutoCAD SHX Text C119
AutoCAD SHX Text
194.24 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C121
AutoCAD SHX Text
153.02 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C122
AutoCAD SHX Text
152.59 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C123
AutoCAD SHX Text
612.84 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C124
AutoCAD SHX Text
264.94 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C125
AutoCAD SHX Text
506.62 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C126
AutoCAD SHX Text
117.58 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C127
AutoCAD SHX Text
118.12 sf
AutoCAD SHX Text
CORR.
AutoCAD SHX Text C130
AutoCAD SHX Text
171.40 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C131
AutoCAD SHX Text
140.87 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C132
AutoCAD SHX Text
140.87 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C129
AutoCAD SHX Text
118.12 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C128
AutoCAD SHX Text
118.26 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C133
AutoCAD SHX Text
542.08 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C134
AutoCAD SHX Text
110.03 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C136
AutoCAD SHX Text
109.81 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C137
AutoCAD SHX Text
104.31 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C138
AutoCAD SHX Text
104.31 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C139
AutoCAD SHX Text
107.61 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C140
AutoCAD SHX Text
539.81 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C141
AutoCAD SHX Text
334.57 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C142
AutoCAD SHX Text
165.97 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C143
AutoCAD SHX Text
359.32 sf
AutoCAD SHX Text
KCAB OPS DEPT.
AutoCAD SHX Text
BREAKROOM
AutoCAD SHX Text C144
AutoCAD SHX Text
359.33 sf
AutoCAD SHX Text
KCAB OPS DEPT.
AutoCAD SHX Text C145
AutoCAD SHX Text
533.87 sf
AutoCAD SHX Text
KCAB OPS DEPT.
AutoCAD SHX Text C146
AutoCAD SHX Text
503.36 sf
AutoCAD SHX Text
KCAB EOC CENTER
AutoCAD SHX Text C147
AutoCAD SHX Text
787.65 sf
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C148
AutoCAD SHX Text
42.58 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C149
AutoCAD SHX Text
210.38 sf
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text C150
AutoCAD SHX Text
231.74 sf
AutoCAD SHX Text
MEN
AutoCAD SHX Text C151
AutoCAD SHX Text
287.97 sf
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text C152
AutoCAD SHX Text
52.42 sf
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text C156
AutoCAD SHX Text
229.52 sf
AutoCAD SHX Text
WOMEN
AutoCAD SHX Text C155
AutoCAD SHX Text
635.13 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C154
AutoCAD SHX Text
199.95 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
BREAKROOM
AutoCAD SHX Text C153
AutoCAD SHX Text
817.09 sf
AutoCAD SHX Text
HOUSEKEEP.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C157
AutoCAD SHX Text
175.75 sf
AutoCAD SHX Text
HOUSEKEEP.
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text C158
AutoCAD SHX Text
176.09 sf
AutoCAD SHX Text
JANITOR
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C161
AutoCAD SHX Text
196.85 sf
AutoCAD SHX Text
READY ROOM
AutoCAD SHX Text C114
AutoCAD SHX Text
90.63 sf
AutoCAD SHX Text
FIRE PROT.
AutoCAD SHX Text C160
AutoCAD SHX Text
51.83 sf
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text C163
AutoCAD SHX Text
39.13 sf
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text C164
AutoCAD SHX Text
161.81 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text C165
AutoCAD SHX Text
246.86 sf
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text C162
AutoCAD SHX Text
918.58 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
WOMEN'S
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text C166
AutoCAD SHX Text
283.11 sf
AutoCAD SHX Text
HOUSEKEEPING
AutoCAD SHX Text
MEN'S
AutoCAD SHX Text
LOCKER ROOM
AutoCAD SHX Text C167
AutoCAD SHX Text
287.62 sf
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text C168
AutoCAD SHX Text
92.11 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D101
AutoCAD SHX Text
402.09 sf
AutoCAD SHX Text
READY ROOM
AutoCAD SHX Text D100
AutoCAD SHX Text
94.05 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D102
AutoCAD SHX Text
130.88 sf
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
EQUIPMENT
AutoCAD SHX Text D104
AutoCAD SHX Text
46.52 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D106
AutoCAD SHX Text
101.55 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D107
AutoCAD SHX Text
120.30 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D108
AutoCAD SHX Text
120.70 sf
AutoCAD SHX Text
CORR.
AutoCAD SHX Text D103
AutoCAD SHX Text
540.91 sf
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text D165
AutoCAD SHX Text
CORRIDOR
AutoCAD SHX Text D166
AutoCAD SHX Text
173.28 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D173
AutoCAD SHX Text
121.22 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D174
AutoCAD SHX Text
120.83 sf
AutoCAD SHX Text
STOR.
AutoCAD SHX Text D175
AutoCAD SHX Text
46.02 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D176
AutoCAD SHX Text
141.31 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D177
AutoCAD SHX Text
141.31 sf
AutoCAD SHX Text
CORR.
AutoCAD SHX Text D172
AutoCAD SHX Text
95.43 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D170
AutoCAD SHX Text
107.83 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D168
AutoCAD SHX Text
170.08 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D167
AutoCAD SHX Text
257.54 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text D171
AutoCAD SHX Text
107.61 sf
AutoCAD SHX Text
VACANT
AutoCAD SHX Text C135
AutoCAD SHX Text
109.81 sf
AutoCAD SHX Text
READY ROOM
AutoCAD SHX Text D169
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
DA-3
AutoCAD SHX Text
55.28 sf
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
CA-2
AutoCAD SHX Text
58.31 sf
AutoCAD SHX Text
ESCALATOR
AutoCAD SHX Text
ELEVATOR
AutoCAD SHX Text
CA-4
AutoCAD SHX Text
68.51 sf
AutoCAD SHX Text
ESCALATOR
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text
FHC
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text
AED
AutoCAD SHX Text L
AutoCAD SHX Text
FE
AutoCAD SHX Text
FE
AutoCAD SHX Text L
AutoCAD SHX Text
CAB. HTR. HWCH-CA-8
AutoCAD SHX Text
HOT WATER PIPING
AutoCAD SHX Text
READY ROOM
AutoCAD SHX Text C159
AutoCAD SHX Text
68.93 sf
AutoCAD SHX Text
FAN COIL UNIT FCU-6
AutoCAD SHX Text
W.H. #A-R-WH1
AutoCAD SHX Text
FEC
AutoCAD SHX Text
SOV
AutoCAD SHX Text
FE
AutoCAD SHX Text
SOV
AutoCAD SHX Text
CAB. HEATER HWCH-CA-5
AutoCAD SHX Text
FE
AutoCAD SHX Text
FHC
AutoCAD SHX Text
PIPE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FEC
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text L
AutoCAD SHX Text
FEC
AutoCAD SHX Text
FAN COIL FCU-CA-3
AutoCAD SHX Text
SOV
AutoCAD SHX Text
FAN COIL FCU-CA-4
AutoCAD SHX Text
FAN COIL FCU-C
AutoCAD SHX Text
AIR HANDLER AHU-4
AutoCAD SHX Text
CONTROL PANEL AHU-CA-4
AutoCAD SHX Text
FEC
AutoCAD SHX Text
CAB. HTR. HWCH-CA-9
AutoCAD SHX Text L
AutoCAD SHX Text
EP #H-AA
AutoCAD SHX Text
EP #L-AA
AutoCAD SHX Text
PUMP P-CA-9
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C21
AutoCAD SHX Text
239.05 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C23
AutoCAD SHX Text
317.62 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C7
AutoCAD SHX Text
129.66 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C6
AutoCAD SHX Text
190.98 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C24
AutoCAD SHX Text
319.80 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text C20
AutoCAD SHX Text
202.36 sf
AutoCAD SHX Text
STAIR
AutoCAD SHX Text D9
AutoCAD SHX Text
217.68 sf
AutoCAD SHX Text
CAB. HTR. HWCH-CA-4
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
UP
AutoCAD SHX Text
MEP/
AutoCAD SHX Text
NO ACCESS
AutoCAD SHX Text
CNA1
AutoCAD SHX Text
14.90 sf
AutoCAD SHX Text
CAGED SMOKING AREA NO DRIVE THRU ACCESS
AutoCAD SHX Text
PIPE
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text A-12
AutoCAD SHX Text
AutoCAD SHX Text A-11
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
| Business Case - Concourse A Ramp Level Upgrade |
| Construction ROM - GRW Rev1 |
| Room Finish Schedule 5035-09-A601-TA |
| Sheets and Views |
| A601 |
| Floor Plan Proposed X-5035-09-Conc.A Level |
| Sheets and Views |
| Layout1 |
| 2025-02-04T04:19:22-0800 | |
| Agreement certified by Adobe Acrobat Sign |
File details come from the government source that posted it. Updated .