Q and A for B-41660 JPMC Dump Trucks - Bid Amendment 2~1.pdf

PDF 217 KB Posted

Attached to
JPMC Dump Trucks
Solicitation number
24-416CMS-BOSS4-B-41660
Issued by
Illinois

About this file

This document contains questions and answers related to Bid Amendment 2 for the Illinois Department of Central Management Services (DCMS) and Illinois Tollway (Tollway) procurement of JPMC Dump Trucks, solicitation #23-416CMS-BOSS4-B-41660. The bid opening has been extended to August 15, 2024. The procurement includes specifications for single axle dump trucks with 240-gallon pre-wet systems, tandem axle dump trucks with 390-gallon pre-wet systems, and tandem axle 6x6 dump trucks with 540-gallon pre-wet systems. Respondents are allowed to propose alternative designs that meet or exceed the stated specifications. The Tollway will review and approve alternative designs as appropriate.

Pricing terms, set-asides, incumbents, funding sources, and other salient details are not provided in this document. The focus is on responding to technical questions about the specifications and allowing for alternative approaches that meet or exceed the requirements. The document indicates the intent is to procure equipment that meets the agencies' operational and safety needs.

View the file

Other files

File Type Posted
251-60-05 One Way Plow 12' No hitch adapter.docx DOCX document
251-60-05 One Way Plow 12' w 6x6 hitch.docx DOCX document
252-60-25 Plow 36In Moldboard Poly.docx DOCX document
254-60-01 Mid Mt Wng R L.docx DOCX document
254-60-26 Mid Rear Wing Scrpr Combo.docx DOCX document
260-60-01 Roller Mill Prewt.docx DOCX document
5012-850-1003 Tollway Single Axle Dump Truck With 240-Gal Pre-wet System~1.docx DOCX document
B-41660 IFB JPMC Dump Trucks_2.docx DOCX document
Blank Vendor Disclosures - Formerly Forms A - v.24.1~2.docx DOCX document
T65-60-01 Crew Cab Singl Dmp~1.docx DOCX document
T68-60-01 Tand 15Ft Dump~2.docx DOCX document
T68-60-01AS Tand 13Ft AS~2.docx DOCX document
252-60-27 Plow Single Ext Discharge.docx DOCX document
254-60-02 HD Bench Wing~1.docx DOCX document
255-60-01 Under Body Scraper.docx DOCX document
261-60-18 Contract SS Fixed Dual Spr chutes.docx DOCX document
264-60-01 RDS Front Convey Direct Place Sprdr.docx DOCX document
269-60-10 Contract Salt Brine App Tand.docx DOCX document
5012-850-1014A - 20' Snow Plow Wing.docx DOCX document
B-41660 JPMC Dump Trucks Certified Vendor List 061124.xlsx XLSX spreadsheet
B-41660 Pre-Bid Conference WebEx Information.docx DOCX document
T70-60-01 6x6 Dr 15Ft RDS~1.docx DOCX document
221-60-04 Trk Broom 10Ft.docx DOCX document
257-60-01 Plow L & R High Discharge.docx DOCX document
257-60-05 Plow High Mold Rev Ext Ears 6x6.docx DOCX document
257-60-05 Plow High Mold Rev Ext Ears.docx DOCX document
261-60-16 Contract SS Dual Spr~2.docx DOCX document
269-60-05 Contract Salt Brine App Sing.docx DOCX document
5012-850-1003A Tollway Combination 11FT Flat Sided and Flat Floor Dump-Spreader~1.docx DOCX document
5012-850-1008 Tollway Tandem Axle Dump Truck With 390-Gallon Pre-wet System.docx DOCX document
5012-850-1013 Tollway Tandem Axle 6X6 Dump Truck With 540 Gallon Pre-wet System~1.docx DOCX document
5012-850-1014 Tollway Super Tandem Axle Dump Truck With 540 Gallon Pre-wet System~1.docx DOCX document
Q and A for B-41660 JPMC Dump Trucks.pdf PDF
T57-60-01 Singl Dmp 4x4 Non CDL~1.docx DOCX document
IPG Active Registered Vendor Disclosure-formerly-forms-b~8.docx DOCX document
252-60-26 Plow 41-44in Moldboard Poly.docx DOCX document
253-60-01 V Plow Super Tandem.docx DOCX document
261-60-14 Contract Spec SS Spr~2.docx DOCX document
5012-850-1014B - 8' Mid-Mount Junior Wing.docx DOCX document
T64-60-01 Singl Dmp~1.docx DOCX document
T66-60-01 Tandem 13 ft~2.docx DOCX document
T68-60-02AS Tand 15FT AS~2.docx DOCX document
Utilization Plan V.24.1~3.pdf PDF
Vendor Instructions Export Upload Items v23 (1)~1.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Illinois Department of Central Management Services JPMC Dump Trucks

23-416CMS-BOSS4-B-41660

Questions and Answers #2

07/31/2024

Below are responses to questions received prior to publication of Q & A #1.

Bid Opening is extended to 08/15/2024

Specification Questions:

Q1 Would the state please consider alternate joystick configurations since the system as specified is proprietary to a singular body builder?

A1 Tollway - The joystick design was to meet the Tollway requirements for proper operation and safety, we are not looking for an off the shelf standard model. The Tollway will review and approve a joystick design that can be built to equal or exceed those features that are called for in the specification.

IDOT - The “control system” is made up of several components. The joystick design was to meet IDOT requirements with safety features included that were not an off the shelf standard model; to IDOT’s knowledge a joystick design can be built to equal or exceed those features called for in the specification, company examples below. The controller or CPU is a Force America and is available off the shelf to any entity. Multiple DOT’s use Force America products. See Specification requirement.

Q2 Would the state please consider other hydraulic control systems if they meet similar function as the Force controllers specified.

A2 The “control system” is made up of several components. The joystick design was to meet IDOT requirements with safety features included that were not an off the shelf standard model; to IDOT’s knowledge a joystick design can be built to equal or exceed those features called for in the specification, company examples below. The controller or CPU is a Force America and is available off the shelf to any entity. Multiple DOT’s use Force America products. See Specification requirement.

Q3 5012-850-1003 Tollway Single Axle Dump Truck With 240-Gal Pre-wet System:

Q3.1 Can more detailed specifications of Monroe for Model MH100ILTW or Wausau Model 4A-03453 be provided to allow other manufacturers to bid?

A3.1 No additional details are available. Tollway will approve alternative designs equal to or greater than the specification.

Q3.2 Can the state provide more detailed specifications on the combination body? It appears this portion of the specification is missing.

A3.2 See specification 5012-850-1003A for the specification details. This specification is complete in detail.

Q4 5012-850-1008 Tollway Tandem Axle Dump Truck With 390-Gallon Pre-wet System:

Q4.1 Can the state provide more detailed specifications on Monroe Model MP 45R12 or Wausau R4512 to allow other manufacturers to bid on this equipment?

A4.1 No additional details are available. Tollway will approve alternative designs equal to or greater than the specification.

Q4.2 Can the state provide more detailed specifications on Monroe for Model MH100ILTW or Wausau Model 4A-03453 to allow other manufacturers to bid on this equipment?

A4.2 No additional details are available. Tollway will approve alternative designs equal to or greater than the specification.

Q4.3 Can the state provide more detailed specifications on Monroe Model MJW-8 to allow other manufacturers to bid on this equipment?

A4.3 No additional details are available. Tollway will approve alternative designs equal to or greater than the specification.

Q4.4 65.K Would a Henderson 35° Sloped side Muni Body be acceptable instead of a 43” radius? It would have the following spec changes:

• 86” inside width to the toprails, with an 85” width to the side sheets.

• Toprail sloped to inside (due to internal toprail)

• Conveyor width of 28.5” and pintle chain width of 25.125” center to center. Each link would be 1.25” x .375”

A4.4 Yes, Tollway will review alternative designs equal to or greater than the specification.

Q4.5 62. GG-QQ. The hoist specifications describe a discontinued cylder that has since been revised from this specification. Would the state consider revising this section with:

• Cylinder shall be bleederless and capable of operating at 2500 PSI.

• The cylinder shall be a trunion mounted telescopic. It shall be installed with the largest stage at the bottom for stability. An inverted telescopic hoist will not be accepted.

• All components of this cylinder except for the seal kit shall be processed through a liquid salt bath nitriding treatment to enhance the surface hardness and corrosion resistance. Hardness achieved will be Rockwell C scale 55 – 60, and corrosion resistance will be roughly three times that of hard chrome plating.

• The cylinder shall be a rod seal design, with seals and wipers installed at the top of each section. Tubes will be surrounded by oil when retracted.

• There will be an oscillating collar on the outer cover of the cylinder to allow the body to be offset 5º to 7º without transferring that side load to either the truck frame or the cylinder tubes, and therefore enhancing stability, and longevity.

• The cylinder shall be assembled from the bottom and have no threaded gland nuts.

There shall be no wear bands in this cylinder as the hardened steel tubes are designed to run adjacent to one another on a thin film of oil."

A4.5 Yes, Tollway will review alternative designs equal to or greater than the specification.

Q5 5012-850-1013 Tollway Tandem Axle 6X6 Dump Truck With 540 Gallon Pre-wet System:

Q5.1 65.B Body shall have ability to be used as a dump body or spreader without the installation of any device allowing the material to discharge through the tailgate onto a spinner assembly by way of an integral center conveyor chain assembly. Is using the body as a dump body be acceptable without covering the chain? Often times a removable floor cover is inserted to protect the chain when hauling items like rock or rip-rap.

A5.1 Yes

Q5.2 65.K Would a Henderson 35° Sloped side Muni Body be acceptable instead of a 43” radius? It would have the following spec changes:

• 86” inside with to the toprails, with an 85” width to the side sheets.

• Toprail sloped to inside (due to internal toprail)

• Conveyor width of 28.5” and pintle chain witdth of 25.125” center to center. Each link would be 1.25” x .375”

• Would 460 gal of prewet be acceptable ILO 540?

A5.2 Tollway will review alternative designs equal to or greater than the specification. A 460 gal pre-wet system would not be allowed. The systems are being used to pretreat road surfaces with brine.

Q5.3 65. GG-QQ. The hoist specifications describe a discontinued cylder that has since been revised from this specification. Would the state consider revising this section with:

• Cylinder shall be bleederless and capable of operating at 2500 PSI.

• The cylinder shall be a trunion mounted telescopic. It shall be installed with the largest stage at the bottom for stability. An inverted telescopic hoist will not be accepted.

• All components of this cylinder except for the seal kit shall be processed through a liquid salt bath nitriding treatment to enhance the surface hardness and corrosion resistance. Hardness achieved will be Rockwell C scale 55 – 60, and corrosion resistance will be roughly three times that of hard chrome plating.

• The cylinder shall be a rod seal design, with seals and wipers installed at the top of each section. Tubes will be surrounded by oil when retracted.

• There will be an oscillating collar on the outer cover of the cylinder to allow the body to be offset 5º to 7º without transferring that side load to either the truck frame or the cylinder tubes, and therefore enhancing stability, and longevity.

• The cylinder shall be assembled from the bottom and have no threaded gland nuts.

There shall be no wear bands in this cylinder as the hardened steel tubes are designed to run adjacent to one another on a thin film of oil.

A5.3 Yes, Tollway will review alternative designs equal to or greater than the specification

Q6. 251-60-05 One Way Plow 12' No hitch adapter: Would 10ga ASTM A572 be acceptable in lieu of 10ga A569 for the moldboard sheet?

A6 Yes, alternative materials shall meet or exceed specification requirements.

Q7 251-60-05 One Way Plow 12' w 6x6 hitch: Would 10ga ASTM A572 be acceptable in lieu of 10ga A569 for the moldboard sheet?

A7 Yes, alternative materials shall meet or exceed specification requirements.

Q8 252-60-27 Plow Single Ext Discharge: Is it acceptable to use one row of 4” x 4" x 3/8" formed plate?

A8 Vendor shall meet or exceed specification requirements.

Q9 253-60-01 V Plow Super Tandem: Would 10ga ASTM A572 be acceptable in lieu of 10ga A569 for the moldboard sheet?

A9 Yes, alternative materials shall meet or exceed specification requirements.

Q10 254-60-01 Mid Mt Wng R L:

Q10.1 Would 10ga ASTM A572 be acceptable in lieu of 10ga A569 for the moldboard sheet?

A10.1 Yes, alternative materials shall meet or exceed specification requirements.

Q10.2 Front Post: Would a Nitrided front lift cylinder be acceptable ILO a Socatri 1000 corrosion resistant rod?

A10.2 Yes, Nitride coating shall meet Socatri 1000 certified corrosion resistance rating of 10. Neutral salt spray Duration >1000 hours / Acetic acid salt spray >350 hours (No Corrosion)

Q10.3 Wing Heel Hydraulic Cylinders: Would a 3’’ x 11’’ cylinder with a nitrided rod be acceptable in lieu of a 3 x 10 with a Socatri 1000 corrosion resistant rods?

A10.3 Yes, Nitride coating shall meet Socatri 1000 certified corrosion resistance rating of 10. Neutral salt spray Duration >1000 hours / Acetic acid salt spray >350 hours (No Corrosion)

Q11 254-60-26 Mid Rear Wing Scrpr Combo: Would a Nitrided cylinder be acceptable ILO a 4" x 8" Socatri 1000 corrosion resistant rod?

A11 Yes, Nitride coating shall meet Socatri 1000 certified corrosion resistance rating of 10.

Neutral salt spray Duration >1000 hours / Acetic acid salt spray >350 hours (No Corrosion)

Q12 255-60-01 Under Body Scraper: Would a 4" x 12.5" Nitrided cylinder be acceptable ILO a 4" x 8" Socatri 1000 corrosion resistant rod?

A12 Yes, Nitride coating shall meet Socatri 1000 certified corrosion resistance rating of 10.

Neutral salt spray Duration >1000 hours / Acetic acid salt spray >350 hours (No Corrosion)

Q13 257-60-01 Plow L & R High Discharge:

Q13.1 Would a Height at left and right discharge of 56” and taper to a center height of 40” be acceptable?

A13.1 Yes, See specification Note:

Note: The intake and discharge taper measurement will depend on the length of moldboard called for in the proposal. IDOT is aware measurements may vary per manufacturer.

Q13.2 Is it acceptable to use one row of 4” x 4" x 3/8" formed plate?

A13.2 Vendor shall meet or exceed specification requirements.

Q14 257-60-05 Plow High Mold Rev Ext Ears 6x6: Is it acceptable to use one row of 4” x 4" x 3/8" formed plate?

A14 Vendor shall meet or exceed specification requirements.

Q15 257-60-05 Plow High Mold Rev Ext Ears: Is it acceptable to use one row of 4” x 4" x 3/8" formed plate?

A15 Vendor shall meet or exceed specification requirements.

Q16 261-60-14 Contract Spec SS Spr2: Page 6 - Pulse Generator:

Q16.1 Would an external speed sensor that provides 512 pulses per auger revolution with a Brad Harrison connector be acceptable in place of a sensor that is integral to the motor?

A16.1 Per Specification: Yes, on pulses. Please see intent below on Sensor.

The Auger Drive Hydraulic Motor shall have an integral built in speed sensor. The speed sensor shall supply a minimum of 100 pulses per revolution. The speed sensor shall include a Brad Harrison type of connector to the unit.

The sensor when fastened in or on the hydraulic motor shall provide a sealed environment for the “pickup” end of sensor. Open shaft sensors that expose “pickup” to the elements are not acceptable.

Sensor below is sealed once electrical connection is made.

Q16.2 The spec calls for the spinner to be a high visibility color, would the color black be acceptable?

A16.2 No, black is not a high visibility color; yellow, orange, and red have been accepted in the past.

Q17 261-60-16 Contract SS Dual Spr2:

Q17.1 Page 6 – Auger Drive: Is the purpose of the reversing valve to change the rotation of the auger to direct material to the passenger (far right) side of the unit instead of the far-left side?

A17.1 Yes

Q17.2 Is the intent to have a 2-way hydraulic valve on the return line of the spinner on the driver side (left side) of the unit?

A17.2 No

Therefore, when the auger reversing valve is activated the 2-way hydraulic valve would also be activated and divert oil to the second spinner instead of back to tank. Please confirm if that is the intent.

A17.2 Not required

Q17.3 The spec calls for the spinner to be a high visibility color, would the color black be acceptable?

A17.3 No, black is not a high visibility color; yellow, orange, and red have been accepted in the past.

Q17.4 Pulse Generator: Would an external speed sensor that provides 512 pulses per auger revolution with a Brad Harrison connector be acceptable in place of a sensor that is integral to the motor?

A17.4 Per Specification: Yes, on pulses. Please see intent below on Sensor.

The Auger Drive Hydraulic Motor shall have an integral built in speed sensor. The speed sensor shall supply a minimum of 100 pulses per revolution. The speed sensor shall include a Brad Harrison type of connector to the unit.

The sensor when fastened in or on the hydraulic motor shall provide a sealed environment for the “pickup” end of sensor. Open shaft sensors that expose “pickup” to the elements are not acceptable.

Sensor below is sealed once electrical connection is made.

Q18 269-60-05 Contract Salt Brine App Sing:

Q18.1 Would a 5 psi poly check valve be acceptable in place of a stainless steel check valve?

A18.1 No, please build per specification.

Q18.2 Would a 1-½" schedule 10 center boom be acceptable in place on a 2” center boom?

A.18.2 No, please build per specification.

Q19 269-60-10 Contract Salt Brine App Tand:

Q19.1 Would a 5 psi poly check valve be acceptable in place of a stainless steel check valve?

A19.1 No, please build per specification

Q19.2 Would a 1-½" schedule 10 center boom be acceptable in place on a 2” center boom?

A19.2 No, please build per specification

Q20 5012-850-1003 TOLLWAY: Would LED ilo TFT LCD monitor be acceptable for camera system?

A20 Yes, Tollway will review alternative designs equal to or greater than the specification.

File details come from the government source that posted it. Updated .