1/8" = 1'-0" 0 8' 16'4'1 2602 FLOOR PLAN LEVEL 1 - RENO
PLAN
NORTH
PROGRESS
DRAWING - DO NOT
USE FOR
CONSTRUCTION
2246 Yaupon Drive
Wilmington, NC 28401
Phone: 910.791.4000
Fax: 910.791.5266 www.cbhfengineers.com
NC# P-0506
c
Copyright 2019 CBHF Engineers, PLLC
Engineers, PLLC
DISCLOSURE OF INFORMATION:
CONTRACTOR SHALL COMPLY AS FOLLOWS:
A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G. FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT
OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
1. THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR
2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF THE RELEASE.
B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING
OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.
C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT.
SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR
TO THE CONTRACTING OFFICER.
THE RFP-DOCUMENTS (RFPD), INCLUDING BUT NOT LIMITED TO: THE DRAWINGS, PLANS, DESIGNS, REPORTS, SURVEYS, CALCULATIONS, COMPUTER PRINT-OUTS, ETC. ARE MADE AVAILABLE TO THE CONTRACTOR'S FOR REFERENCE PURPOSES ONLY IN RELATION TO THIS DESIGN-BID PROJECT. THE RFPD ARE THE PROPERTY OF THE GOVERNMENT.
THE RFPD ARE PROVIDED "AS-IS" WITHOUT ANY GUARANTEE, REPRESENTATION, CONDITION, OR WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, OR STATUTORY.
THE GOVERNMENT ASSUMES NO LIABILITY WITH RESPECT TO ANY RELIANCE THE CONTRACTOR(S) PLACE ON THESE RFPD. IF THE CONTRACTOR(S) RELY ON THESE RFPD IN ANY WAY, THE CONTRACTOR(S) ASSUME THE ENTIRE RISK AS TO THE TRUTH, ACCURACY, CURRENCY, OR COMPLETENESS OF THE INFORMATION CONTAINED IN THESE RFPD.
KEYED NOTES
NOTE: SELECT KEYED NOTES MAY NOT BE USED THIS DRAWING
REMOVE AND DISPOSE OF ENTIRE EXISTING HVAC SYSTEM INCLUDING, BUT NOT LIMITED
TO, PTACS, UNIT HEATERS, EXHAUST FANS, DUCTWORK, DUCT INSULATION, HANGERS
AND SUPPORTS. REMOVE AND DISPOSE OF ENTIRE EXISTING PLUMBING SYSTEM
INCLUDING, BUT NOT LIMITED TO, DOMESTIC HEATING WATER EQUIPMENT, PLUMBING
FIXTURES/TRIM, PUMPS, DOMESTIC WATER PIPING, INSULATION, SANITARY/VENT PIPING,
HANGERS AND SUPPORTS.
PROVIDE AIR-COOLED CHILLER ON CONCRETE HOUSEKEEPING PAD (TOP OF
PAD 10” ABOVE ADJACENT GRADE). PROVIDE INSULATED AND JACKETED CHILLED
WATER PIPING FROM CHILLER TO MECHANICAL ROOM FOR DISTRIBUTION THROUGHOUT
THE FACILITY. ALL PARTS OF THE EXTERIOR CHILLED WATER SYSTEM SUBJECT TO
FREEZING MUST BE HEAT TRACED TO PREVENT FREEZING DOWN TO 0 DEGREES F.
PROVIDE EXTERIOR PIPING WITH EMERGENCY CHILLER CONNECTIONS. A SET OF
EMERGENCY TEES MUST BE INSTALLED BEFORE ENTERING THE CHILLER ON SUPPLY
AND RETURN LINES. THE TEES MUST MATCH THE DIAMETER OF THE PIPE. A BUTTERFLY
VALVE AND A BOLTED COVER PLATE MUST BE INSTALLED.
PROVIDE BOILERS ON 6” HOUSEKEEPING PADS. PROVIDE IN-LINE CLOSE-COUPLED
CONSTANT VOLUME SOURCE SIDE PUMPS (ONE PER BOILER) AND LEAD-STANDBY
VARIABLE VOLUME LOAD SIDE HEATING WATER SYSTEM PUMPS DISTRIBUTING HEATING
WATER THROUGHOUT THE FACILITY.
PROVIDE IN-LINE CLOSE-COUPLED LEAD-STANDBY CONSTANT VOLUME SOURCE SIDE
PUMPS AND LEAD-STANDBY VARIABLE VOLUME LOAD SIDE CHILLED WATER SYSTEM
PUMPS DISTRIBUTING CHILLED WATER THROUGHOUT THE FACILITY.
PROVIDE A FOUR-PIPE DEDICATED OUTSIDE AIR SYSTEM (DOAS) WITH TOTAL ENERGY
CORE TO DISTRIBUTE FULLY CONDITIONED AIR THROUGHOUT THE FACILITY. ALL
FACILITY EXHAUST AIR MUST BE ROUTED BACK THROUGH THIS UNIT FOR ENERGY
RECOVERY. OFF COOLING COIL AIR MUST NOT EXCEED 50F. NEUTRAL AIR MUST BE
DELIVERED TO EACH AREA DECOUPLED FROM TERMINAL SYSTEMS. BUILDING
PRESSURE MUST BE POSITIVE.
PROVIDE DUCTLESS SPLIT SYSTEM HEAT PUMP FOR DATA/TEL ROOM. ONE SYSTEM PER
ROOM.
PROVIDE VERTICAL HIGH-RISE FOUR-PIPE FAN-COIL UNIT FURRED IN WALL FOR
TEMPERATURE AND HUMIDITY CONTROL IN EACH SUITE. POSITION THE FAN-COIL SUCH
THAT SIDEWALL SUPPLY DIFFUSERS CAN SERVE THE LIVING AREA AND THE SLEEPING
AREA FROM ONE UNIT. PROTOCOL SUITES MAY HAVE ONE FAN-COIL EACH FOR LIVING
AREA AND SLEEPING AREA. PROVIDE EXHAUST GRILLE IN HEAD AND VENTILATION
REGISTER IN BOTH THE LIVING AND SLEEPING AREAS FROM THE DOAS.
PROVIDE SEMI-CUSTOM FOUR-PIPE AIR HANDLING UNIT IN CLOSET FOR TEMPERATURE
AND HUMIDITY CONTROL IN COMMON AREA. PROVIDE EXHAUST GRILLE IN HEAD/
CUSTODIAL ROOM AND VENTILATION REGISTERS IN COMMON AREAS FROM THE DOAS.
PROVIDE GAS-FIRED WATER HEATER(S) AND DOMESTIC HOT WATER RECIRCULATION
PUMP TO DISTRIBUTE DOMESTIC HOT WATER THROUGHOUT THE FACILITY. PROVIDE
DOMESTIC COLD WATER BACKFLOW PREVENTER. DISTRIBUTE DOMESTIC COLD WATER
THROUGHOUT THE FACILITY. PROVIDE DOMESTIC WATER AND SANITARY/VENT UTILITIES
FOR EACH FIXTURE AND EQUIPMENT REQUIRING THESE UTILITIES THROUGHOUT THE
FACILITY.
3 4
5 9
AutoCAD SHX Text
SYM
AutoCAD SHX Text
DATE
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
SATISFACTORY TO: DATE
AutoCAD SHX Text
APPROVED: PWO OR OICC DATE
AutoCAD SHX Text
DESIGN DIR.
AutoCAD SHX Text
SUBMITTED BY:
AutoCAD SHX Text
DR.
AutoCAD SHX Text
CHK.
AutoCAD SHX Text
DES.
AutoCAD SHX Text
CAMP LEJEUNE, NORTH CAROLINA
AutoCAD SHX Text
CONST. CONTR.
AutoCAD SHX Text
MARINE CORPS BASE
AutoCAD SHX Text
DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text E1
AutoCAD SHX Text
SIZE
AutoCAD SHX Text 80091
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
CODE IDENT. NO
AutoCAD SHX Text
NAVFAC DRAWING NO.
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text 18168
AutoCAD SHX Text BOQs 2602, 2603, 2604, 2605
AutoCAD SHX Text 2607, 2609, 2611, 2613, 2617
AutoCAD SHX Text 20-0046
AutoCAD SHX Text
NA
AutoCAD SHX Text
NOTED
AutoCAD SHX Text
FINAL 21MAY 2020
AutoCAD SHX Text
T H BURTON, PE
AutoCAD SHX Text M-103
AutoCAD SHX Text
BOQ 2602 LEVEL 1 FLOOR PLAN
AutoCAD SHX Text
AutoCAD SHX Text
DMH
AutoCAD SHX Text
GRM
AutoCAD SHX Text
DMH
AutoCAD SHX Text
| Sheets and Views |
| M103 |
| OLE1 |