PART 6 ATTACHMENT L-EXAMPLE SCREEN WALL.pdf

PDF 153 KB Posted

Attached to
Repair Nine Paradise Point BOQs
Solicitation number
N6247020R6019
Issued by

View the file

Other files

File Type Posted
20-0046 PART 3-- PPI RESPONSE 5_13AUG2020.pdf PDF
Amnd 0007 20R6019 FINAL.pdf PDF
Amnd 0006 20R6019 FINAL.pdf PDF
Amnd 0005 20R6019 FINAL.pdf PDF
20-0046 PART 3-- PPI RESPONSE 4_07AUG2020.pdf PDF
20-0046 PART 3-- PPI RESPONSE 3_06AUG2020.pdf PDF
Amnd 0004 20R6019 FINAL.pdf PDF
Amnd 0003 20R6019 FINAL.pdf PDF
Roof Louvers 2617.jpeg JPEG file
Amnd 0002 20R6019 FINAL.pdf PDF
PART 6 ATTACHMENT N-MCBCL Base-Wide MNS-FACP Construction Requirements 28 JAN 2015 Typical.pdf PDF
01 31 19.05 20 Post Award Meetings-Revised 20JUL2020.pdf PDF
20-0046 Paradise Point BOQs - REV SP1.pdf PDF
01 31 10.05 20 Design Submittal Procedure-Revised 20JUL2020.pdf PDF
23 73 33 HEATING VENTILATING AND COOLING SYSTEM.pdf PDF
20-0046 Paradise Point BOQs - REV A101.pdf PDF
20-0046 PART 3-- PPI RESPONSE 1_20JUL2020.pdf PDF
11 24 24 ROOF FALL PROTECTION 20 Nov 2019.pdf PDF
Amnd 0001 20R6006 FINAL.pdf PDF
PART 6 ATTACHMENT F-NPDES PERMIT NCS000290.pdf PDF
PART 5 FINAL-28MAY2020.pdf PDF
PART 6 ATTACHMENT M9-M602 MECHANICAL CONTROLS.pdf PDF
PART 6 ATTACHMENT I9-879291-2603-INT_EXT REPAIRS.pdf PDF
PART 6 TOC-20-0046.pdf PDF
PART 6 ATTACHMENT I3-85-6406 BOQ Improvements.pdf PDF
PART 6 ATTACHMENT H-BOQ FURNITURE INVENTORY.pdf PDF
PART 6 ATTACHMENT K- MCBCL Mech Design Guidance 7.17.pdf PDF
PART 6 ATTACHMENT M5-M105 BOQ 2603 THRU 2611 LEVEL 1.pdf PDF
PART 6 ATTACHMENT I5-91-7314 BOQs Sidewalks-2.pdf PDF
PART 3 FINAL-28MAY2020.pdf PDF
PART 6 ATTACHMENT A3-EXISTING BUILDING PICTURES PT2.pdf PDF
PART 6 ATTACHMENT E3-ES101 BOQ SITE PRIMARY O.H. POWER PLAN.pdf PDF
Master PPI Form Template.xls XLS spreadsheet
PART 6 ATTACHMENT M2-M102 BOQ 2617 LEVEL 2.pdf PDF
PART 6 ATTACHMENT A1-BOQ FLOOR PLAN REFERENCES.pdf PDF
PART 6 ATTACHMENT M10-M603 MECHANICAL CONTROLS.pdf PDF
PART 6 ATTACHMENT I6-95-1430 HVAC BOQs.pdf PDF
PART 6 ATTACHMENT M3-M103 BOQ 2602 LEVEL 1.pdf PDF
PART 6 ATTACHMENT D2- Appendix D for DEMO.pdf PDF
RFP N6247020R6019.pdf PDF
PART 6 ATTACHMENT M4-M104 BOQ 2602 LEVEL 2.pdf PDF
PART 6 ATTACHMENT M7-M107 BOQ 2613 LEVEL 1.pdf PDF
PART 6 ATTACHMENT E1-Electrical Policies 2020.pdf PDF
PART 6 ATTACHMENT I10-994214 - 2603_2609_2611_2613-REPL HVAC.pdf PDF
PART 6 ATTACHMENT A2-BOQ FRONT DESK FLOOR PLANS.pdf PDF
PART 6 ATTACHMENT D1-BASE ASBESTOS REPORTS-ALL BUILDINGS.pdf PDF
PART 6 ATTACHMENT E2-TS101 BOQ SITE TELECOMM PLAN.pdf PDF
PART 6 ATTACHMENT E4-ES102 BOQ SITE SECONDARY O.H. POWER PLAN.pdf PDF
PART 6 ATTACHMENT I8-1942 BOQs.pdf PDF
PART 6 ATTACHMENT M8-M601 MECHANICAL CONTROLS.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VENTILATED BRICK WALL

EXISTING

BUILDING WALL

BRICK PILASTER

5" PRECAST CONCRETE

CAP @ PILASTERS -

BEVEL 4 SIDES MECHANICAL UNIT HIDDEN

FOR CLARIFICATION

CONCRETE PAD,

REF: STRUCT.

1' - 0" 6' - 9" 1' - 0" 3' - 6"

8" 8" 6'-8" 6'-8" 8" 8" +/- 8"

8' -4

7"

4" 2" 10

2"

6' -1

2"

7"

CONCRETE MOW

STRIP

LEVEL 1

100'-0"

5" PRECAST CONCRETE

CAP @ PILASTERS -

BEVEL 4 SIDES

8'-4" BRICK PILASTER

ORNAMENTAL STEEL

PICKET FENCING

MECHANICAL UNIT

HIDDEN FOR CLARIFICATION

CONCRETE PAD BEYOND,

REF: STRUCT.

+/- 8" 1'-4" 6'-8" 6'-8" 1'-4"

13'-4"

7" 8'

-4

TYP.

4"

7" 2"

6' -1

2"

2"

CONCRETE FOOTING

BRICK PILASTER

5" PRECAST CONCRETE CAP

@ PILASTERS - BEVEL 4 SIDES

METAL GATE

ORNAMETAL STEEL

PICKET GATE AND POSTS

8' -4

7"

7' -1

0"

1'-4" 11'-5" 1'-4" 5'-7" 5'-7"

TYP.

4"

1'

4"

1' - 4"

GROUT SOLID FULL HEIGHT,

REF: STRUCT.

BRICK PILASTER

ORNAMENTAL STEEL

PICKET FENCING

ARCHITECTURE

P R

O

JE

C T

-0

R E

N O

V A

TI

O

N O

F B

U

IL

D

IN

G

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

C O

M M

A N

D

A

B

C

2 3 4 5

1 2 3 4 5

A

B

C

D

IP

T

M

AR

IN

E C O

RP

S B

AS

E C

AM

P L

EJ

EU

N E

C

AM

P L

EJ

EU

N E, N

C

C

AM

P

LE

JE

U N E

C

AM

P

LE

JE

U N E, N

C

D E P A R

TM

E N T O F

TH

E

N A V Y

N A V A L F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

N O

T

FO

R C

O N

S

TR

U C

TI

O

N

B A

C K

C H

E C

K

5909 NW Expressway, Ste. 600 Oklahoma City, OK 73132

(405) 722-7270 www.lwpb.com

S Y M

D E S C R

IP

TI

O N

D A

TE

A P P R

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

RS CB DW

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

DES DRW CHK

SCALE: AS SHOWN

CONSTR. CONTR. NO.

EPROJECT NO.:

SEAL

D

Poettker Construction

N40085-19-F-4464

ECC

Jacksonville, NC

02/10/2020

CB/RS

/1

0/

0% B

AC

KC

H

EC

K

A-609

S C R E E N

W A

LL

D E

TA

IL

S

1/2" = 1'-0"C3 SCREEN WALL SECTION

1/2" = 1'-0"C1 SCREEN WALL ENCLOSURE - TYPICAL

1/2" = 1'-0"B1 STEEL GATE ELEVATION 1 1/2" = 1'-0"B3 PILASTER DETAIL

0 1'6"3" 1' 6"

2'1' 4'0

2'1' 4'0

2'1' 4'0

File details come from the government source that posted it. Updated .