PART 6 ATTACHMENT E4-ES102 BOQ SITE SECONDARY O.H. POWER PLAN.pdf

PDF 242 KB Posted

Attached to
Repair Nine Paradise Point BOQs
Solicitation number
N6247020R6019
Issued by

View the file

Other files

File Type Posted
20-0046 PART 3-- PPI RESPONSE 5_13AUG2020.pdf PDF
Amnd 0007 20R6019 FINAL.pdf PDF
Amnd 0006 20R6019 FINAL.pdf PDF
Amnd 0005 20R6019 FINAL.pdf PDF
20-0046 PART 3-- PPI RESPONSE 4_07AUG2020.pdf PDF
20-0046 PART 3-- PPI RESPONSE 3_06AUG2020.pdf PDF
Amnd 0004 20R6019 FINAL.pdf PDF
Amnd 0003 20R6019 FINAL.pdf PDF
Roof Louvers 2617.jpeg JPEG file
Amnd 0002 20R6019 FINAL.pdf PDF
PART 6 ATTACHMENT N-MCBCL Base-Wide MNS-FACP Construction Requirements 28 JAN 2015 Typical.pdf PDF
01 31 19.05 20 Post Award Meetings-Revised 20JUL2020.pdf PDF
20-0046 Paradise Point BOQs - REV SP1.pdf PDF
01 31 10.05 20 Design Submittal Procedure-Revised 20JUL2020.pdf PDF
23 73 33 HEATING VENTILATING AND COOLING SYSTEM.pdf PDF
20-0046 Paradise Point BOQs - REV A101.pdf PDF
20-0046 PART 3-- PPI RESPONSE 1_20JUL2020.pdf PDF
11 24 24 ROOF FALL PROTECTION 20 Nov 2019.pdf PDF
Amnd 0001 20R6006 FINAL.pdf PDF
PART 6 ATTACHMENT F-NPDES PERMIT NCS000290.pdf PDF
PART 5 FINAL-28MAY2020.pdf PDF
PART 6 ATTACHMENT M9-M602 MECHANICAL CONTROLS.pdf PDF
PART 6 ATTACHMENT I9-879291-2603-INT_EXT REPAIRS.pdf PDF
PART 6 TOC-20-0046.pdf PDF
PART 6 ATTACHMENT I3-85-6406 BOQ Improvements.pdf PDF
PART 6 ATTACHMENT H-BOQ FURNITURE INVENTORY.pdf PDF
PART 6 ATTACHMENT K- MCBCL Mech Design Guidance 7.17.pdf PDF
PART 6 ATTACHMENT M5-M105 BOQ 2603 THRU 2611 LEVEL 1.pdf PDF
PART 6 ATTACHMENT I5-91-7314 BOQs Sidewalks-2.pdf PDF
PART 3 FINAL-28MAY2020.pdf PDF
PART 6 ATTACHMENT A3-EXISTING BUILDING PICTURES PT2.pdf PDF
PART 6 ATTACHMENT E3-ES101 BOQ SITE PRIMARY O.H. POWER PLAN.pdf PDF
Master PPI Form Template.xls XLS spreadsheet
PART 6 ATTACHMENT M2-M102 BOQ 2617 LEVEL 2.pdf PDF
PART 6 ATTACHMENT A1-BOQ FLOOR PLAN REFERENCES.pdf PDF
PART 6 ATTACHMENT M10-M603 MECHANICAL CONTROLS.pdf PDF
PART 6 ATTACHMENT I6-95-1430 HVAC BOQs.pdf PDF
PART 6 ATTACHMENT L-EXAMPLE SCREEN WALL.pdf PDF
PART 6 ATTACHMENT M3-M103 BOQ 2602 LEVEL 1.pdf PDF
PART 6 ATTACHMENT D2- Appendix D for DEMO.pdf PDF
RFP N6247020R6019.pdf PDF
PART 6 ATTACHMENT M4-M104 BOQ 2602 LEVEL 2.pdf PDF
PART 6 ATTACHMENT M7-M107 BOQ 2613 LEVEL 1.pdf PDF
PART 6 ATTACHMENT E1-Electrical Policies 2020.pdf PDF
PART 6 ATTACHMENT I10-994214 - 2603_2609_2611_2613-REPL HVAC.pdf PDF
PART 6 ATTACHMENT A2-BOQ FRONT DESK FLOOR PLANS.pdf PDF
PART 6 ATTACHMENT D1-BASE ASBESTOS REPORTS-ALL BUILDINGS.pdf PDF
PART 6 ATTACHMENT E2-TS101 BOQ SITE TELECOMM PLAN.pdf PDF
PART 6 ATTACHMENT I8-1942 BOQs.pdf PDF
PART 6 ATTACHMENT M8-M601 MECHANICAL CONTROLS.pdf PDF
Show 40 more

Latest 50 of 66 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BLDG

BLDG

BLDG

BLDG

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED AREA

LIGHT

EXISTING MASS

NOTIFICATION

ANTENNA AND

CONTROL PANEL

BLDG

EXISTING

WALKWAY

AREA

LIGHT

EXISTING

WALKWAY

AREA

LIGHT

EXISTING

WALKWAY

AREA

LIGHT

EXISTING

WALKWAY

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE WITH (2) AREA

LIGHTS MUST REMAIN AND BE

OPERATIONAL AFTER

DEMOLITION AND

CONSTRUCTION IS COMPLETE

BLDG

BLDG

S2698

BLDG

BLDG

BLDG

BLDG

S2637

BLDG

S2638

BLDG

BLDG

BLDG

2611A

BLDG

S2643

SETH WILLIAMS BOULEVARD

CH

AR

LE

S

ST

RE

ET

SETH WILLIAMS BOULEVARD

POW

ER H

OUSE R

OAD

SCOUT

HUT

LO

OP

SETH W

ILLIAM

S BO

ULEVARD

PARKING

PARKING

PARKING

EXISTING POLE WITH AREA

LIGHT, OVERHEAD FEED TO

BLDG 2602

EXISTING POLE WITH AREA

LIGHT WITH UNDERGROUND

FEED TO BLDG 2601

EXISTING POLE WITH

AREA LIGHT, WITH

OVERHEAD FEED TO

BLDG 2607

EXISTING POLE

MOUNTED

AREA LIGHTS

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHTS

EXISTING POLE

MOUNTED

AREA LIGHTS

EXISTING POLE

MOUNTED

AREA LIGHTS

EXISTING POLE

MOUNTED

AREA LIGHTS

FENCED

RV/BOAT

STORAGE

EXISTING POLE

MOUNTED

AREA LIGHT

PARKING

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED BREAKER

AND OUTLET FOR

METERING PUMP

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

BLDG

S2696

BLDG

S2697

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE WITH

(3)POLE MOUNTED

TRANSFORMERS

FEEDING BLGD 2607

EXISTING POLE WITH AREA

LIGHT AND OVERHEAD

FEEDING BLDG 2601

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE WITH AREA

LIGHT AND OVERHEAD FEED TO

BLDG 2602

EXISTING POLE WITH AREA

LIGHT AND OVERHEAD

FEED TO BLDG 2603

EXISTING POLE WITH

OVERHEAD FEED TO

BLDG 2605

EXISTING POLE WITH

UNDERGROUND FEED TO

BLDG 2603

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE

MOUNTED

AREA LIGHT

EXISTING POLE WITH AREA

LIGHT, WITH UNDERGROUND

FEED TO EXISTING PAD

MOUNTED TRANSFORMER

EXISTING PAD

MOUNTED

TRANSFORMER

EXISTING POLE WITH AREA

LIGHT, AND UNDERGROUND

FEED TO BLDG 2613

EXISTING POLE WITH AREA

LIGHT, AND OVERHEAD FEED

TO BLDG 2611

EXISTING

POLE

EXISTING POLE WITH OVERHEAD

PRIMARY TO ROD AND GUN CLUB

BUILDING 1933

EXISTING POLE WITH AREA

LIGHT, AND OVERHEAD FEED

TO BLDG 2609

EXISTING POLE

EXISTING POLE

MOUNTED AREA

LIGHT

PROGRESS

DRAWING - DO NOT

USE FOR

CONSTRUCTION

2246 Yaupon Drive

Wilmington, NC 28401

Phone: 910.791.4000

Fax: 910.791.5266 www.cbhfengineers.com

NC# P-0506

c

Copyright 2019 CBHF Engineers, PLLC

Engineers, PLLC

DISCLOSURE OF INFORMATION:

CONTRACTOR SHALL COMPLY AS FOLLOWS:

A. THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G. FILM, TAPE, DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT

OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-

1. THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR

2. THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF THE RELEASE.

B. REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL SUBMIT ITS REQUEST TO THE CONTRACTING

OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.

C. THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER THIS CONTRACT.

SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION TO RELEASE THROUGH THE PRIME CONTRACTOR

TO THE CONTRACTING OFFICER.

THE RFP-DOCUMENTS (RFPD), INCLUDING BUT NOT LIMITED TO: THE DRAWINGS, PLANS, DESIGNS, REPORTS, SURVEYS, CALCULATIONS, COMPUTER PRINT-OUTS, ETC. ARE MADE AVAILABLE TO THE CONTRACTOR'S FOR REFERENCE PURPOSES ONLY IN RELATION TO THIS DESIGN-BID PROJECT. THE RFPD ARE THE PROPERTY OF THE GOVERNMENT.

THE RFPD ARE PROVIDED "AS-IS" WITHOUT ANY GUARANTEE, REPRESENTATION, CONDITION, OR WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED, OR STATUTORY.

THE GOVERNMENT ASSUMES NO LIABILITY WITH RESPECT TO ANY RELIANCE THE CONTRACTOR(S) PLACE ON THESE RFPD. IF THE CONTRACTOR(S) RELY ON THESE RFPD IN ANY WAY, THE CONTRACTOR(S) ASSUME THE ENTIRE RISK AS TO THE TRUTH, ACCURACY, CURRENCY, OR COMPLETENESS OF THE INFORMATION CONTAINED IN THESE RFPD.

1" = 60'-0" 0 60' 120'1 BUILDING 2602, 2603, 2604, 2605, 2607, 2609, 2611, 2613, 2617 SITE PLAN - SECONDARY O.H. POWER

PLAN

NORTH

EXISTING WALKWAY AREA LIGHT

EXISTING POLE MOUNTED AREA LIGHT

HATCHING INDICATES THE APPROXIMATE EXTENT OF OVERHEAD DEMOLITION, CONTRACTOR

MUST FIELD VERIFY EXTENTS OF DEMOLITION.

EXISTING PAD MOUNTED TRANSFORMER

EXISTING POLE MOUNTED TRANSFORMER

EXISTING POWER POLE

EXISTING POLE MOUNTED BREAKER

EXISTING RECEPTACLE

DESCRIPTIONSYMBOL

ELECTRICAL LEGEND

AutoCAD SHX Text

SYM

AutoCAD SHX Text

DATE

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

SATISFACTORY TO: DATE

AutoCAD SHX Text

APPROVED: PWO OR OICC DATE

AutoCAD SHX Text

DESIGN DIR.

AutoCAD SHX Text

SUBMITTED BY:

AutoCAD SHX Text

DR.

AutoCAD SHX Text

CHK.

AutoCAD SHX Text

DES.

AutoCAD SHX Text

CAMP LEJEUNE, NORTH CAROLINA

AutoCAD SHX Text

CONST. CONTR.

AutoCAD SHX Text

MARINE CORPS BASE

AutoCAD SHX Text

DEPARTMENT OF THE NAVY NAVAL FACILITIES ENGINEERING COMMAND

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text E1

AutoCAD SHX Text

SIZE

AutoCAD SHX Text 80091

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

CODE IDENT. NO

AutoCAD SHX Text

NAVFAC DRAWING NO.

AutoCAD SHX Text

SHEET OF

AutoCAD SHX Text 18168

AutoCAD SHX Text BOQs 2602, 2603, 2604, 2605

AutoCAD SHX Text 2607, 2609, 2611, 2613, 2617

AutoCAD SHX Text 20-0046

AutoCAD SHX Text

NA

AutoCAD SHX Text

NOTED

AutoCAD SHX Text

FINAL 21MAY 2020

AutoCAD SHX Text

T H BURTON, PE

AutoCAD SHX Text

ES102

AutoCAD SHX Text

BOQ SITE SECONDARY O.H. POWER PLAN

AutoCAD SHX Text

AutoCAD SHX Text

WAC

AutoCAD SHX Text

HGH

AutoCAD SHX Text

WAC

AutoCAD SHX Text

Sheets and Views
2617 ES102
OLE1

File details come from the government source that posted it. Updated .