This is a request for proposal for the construction of a multi-story housing tower and detached utility building at a U.S. Naval Support Activity facility in Guam. The project includes single-occupancy housing units, common areas, and multipurpose spaces. Offerors must submit price and technical proposals by February 17, 2021 at 2:00 pm Chamorro Standard Time. Site visits will be held on January 12, 2021, with attendance limited to two people per firm. Offerors must submit documentation for base access in advance. The solicitation identifies evaluation criteria and requires that large businesses submit a small business subcontracting plan with proposed goals. It includes various Federal Acquisition Regulation provisions on submissions, negotiations, and contract terms.

View the file

Other files

File Type Posted
Class JA for ECC Elevator Control Systems 20210419 REDACTED.pdf PDF
AMD 0009 21R1334.pdf PDF
21R1334 Note 7 Final.pdf PDF
AMD 0008 21R1334.pdf PDF
21R1334 Note 6 Final.pdf PDF
Amd 07 Rev Dwgs.pdf PDF
AMD 0007 21R1334.pdf PDF
21R1334 Note 5 Final.pdf PDF
Amd 06 rev Dwgs-a.pdf PDF
AMD 0006 21R1334.pdf PDF
Amd 05 Rev DWGS.pdf PDF
AMD 0005 21R1334.pdf PDF
21R1334-Note 4 Final.pdf PDF
Amd 04 revised DWGS.pdf PDF
Amd 03 Civil DWGS reissued.pdf PDF
AMD 0004 21R1334.pdf PDF
Amd 02 Civil DWGS reissued.pdf PDF
21R1334-Note3 Final.pdf PDF
AMD 03 21R1334.pdf PDF
Amd 03 Rev Spec Sections.pdf PDF
Amd 03 Rev DWGS.pdf PDF
Class JA for Dormakaba RFID Locking System_REDACTED.pdf PDF
21R1334-Note2-Final.pdf PDF
Amd 02 BOQ A AMD 02 DWGS_R1 signed.pdf PDF
AMD 02 21R1334.pdf PDF
Amd 02 BOQ A Civil Dwgs - Reissued.pdf PDF
21R1334-Note1-Final.pdf PDF
Amd 01 IMAGE 26 NOV 2020.pdf PDF
Amd 01 1A-5B-1.pdf PDF
Amd 01 6A-8C-1.pdf PDF
AMD 01 21R1334.pdf PDF
Amd 01 J023 site photo key.pdf PDF
J-023 BOQ A Specifications_Signed Off_Volume 2 of 2_.pdf PDF
Class JA - Fed Signal-redacted.pdf PDF
J-023 BOQ A Specifications_Signed Off_Volume 1 of 2_.pdf PDF
Class JA King F Transmitters-Redacted.pdf PDF
J-023 BOQ A Drawings_Signed Off_4 of 4_Electrical Telecommunications.pdf PDF
J-023 BOQ A Drawings_Signed Off_1 of 4_Civil Structural.pdf PDF
MCBG Knox Box Class JA_Redacted.pdf PDF
JA BEQs-BOQs RFID Vingcard-Redacted.pdf PDF
Class JA No 20-016 for AMI Meter (Redacted) w Att A.pdf PDF
J-023 BOQ A Drawings_Signed Off_3 of 4_Fire Protection Mechanical Plumbing.pdf PDF
J-023 BOQ A Drawings_Signed Off_2 of 4_Architectural Interiors.pdf PDF
Class JA for JCI METASYS (20200626)_Redacted.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REQUEST FOR PROPOSAL

N62742-21-R-1334

J-023 BACHELOR OFFICER QUARTERS- A,

US NAVSUPPACT MCB, GUAM

J-023 BACHELOR OFFICER QUARTERS-A WON 972483

RFP N62742-21-R-1334/CONTRACT N62742-21-C-1334

PROJECT TABLE OF CONTENTS

PROJECT TABLE OF CONTENTS

(1) PROPOSAL DOCUMENTS

(A) SOLICITATION, OFFER AND AWARD (SF1442) (Rev. 4-85)

(B) 00100 INSTRUCTIONS TO OFFERORS

(C) 00 01 15 LIST OF DRAWINGS

(D) 00202 EVALUATION FACTORS FOR AWARD

(E) 00600 REPRESENTATIONS AND CERTIFICATIONS

(F) 00700 CONTRACT CLAUSES

(G) 00800 SUPPLEMENTARY CONDITIONS

GUAM GENERAL DECISION NUMBER GU20200002, PUBLICATION DATE

08/07/2020

(H) NAVFAC SPECIFICATION WORK ORDER NO (WON) 972483

(2) CONTRACT FORMS AND CONDITIONS OF THE CONTRACT

(A) SOLICITATION, OFFER AND AWARD (SF1442) (Rev. 4-85)

(B) 00 01 15 LIST OF DRAWINGS

(C) 00700 CONTRACT CLAUSES (FULL TEXT)

(D) 00800 SUPPLEMENTARY CONDITIONS

GUAM GENERAL DECISION NUMBER GU20200002, PUBLICATION DATE AS

UPDATED AT TIME OF AWARD

(E) NAVFAC SPECIFICATION WORK ORDER NO (WON) 972483

SOLICITATION, OFFER, 1. SOLICITATIONINO. 2. lYPEOF SOLICITATION 3. DA TE ISSUED PAGE OF PAGES

AND AWARD □ SEALEDBID (IFB) 17-D3c-2020 (Construction, Alteration, or Repair)

1\627 4221R1334 [j NEGOTIATED

(RFP)

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO. 5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

972483

?. ISSUED BY CODE I N627 42 8. ADDRESS OFFER TO (If Other Than Item 7) CODE I

HAND DELIVER

NAVFAC PACIFIC See Item 7

CONSTRUCTION CONTRACTS BR (ACQ33)

4256 RADFORD DR, BLDG 62

HONOLULU HI 96818-3296

TEL: FAX: TEL: FAX:

9. FOR INFORM/\ TION A. NAME B. TELER-IONE NO. (Include area code) (NO COLLECT CALLS)

CALL: NORINEE HORIKAWA (808) 471-2235

SOLICITATION

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

10. THE GOVERNM8'1T REQUIRES PERFORMANCE OF TIHE WORK DESCRIBED IN THESE DOCU'v18'1TS (Title, identifying no., date):

JFY20 BOOA

RFPN62742-21-R-1334, WORK ORDER NUM3ER 972483, J-023 BACHaOR OFFICER QUARTERS-A, US NAVSUPPACT MCB, GUAM

GENERAL DESCRIPTION: SEE SECT ION 01 11 00, PARA 1.1.1, ffiOJECT DESCRIPTION

THIS ffiOCURBV18'1T IS U�ESTRICTED. North Arrerican Industry Classification System(NAICS) Code 236116 • Average Annual Receipts for the Past 3 Years• S39.5M

MAGNrfUDEOFCONSTRUCTION: BETVVEEN$100M AND $150M

DPAS RA TING: OO-C2

ENFORCEABILITY OF ffiOPOSAL- The proposal rrust set forth full, accurate and complete inforrration as required by this solicitation. The Governrrent will rely on such inforrration in the award of a contract. The aw ardee's proposal w Ill be incorporated into the contract and all iterrs proposed will becorre binding requirerrents of the contract. By subnission of the offer, the offerer agrees that all tirres proposed (e.g., subcontractors with leaning agreements, etc.) will be utilized for the duration of the contract and any substitutions rrust be equal or better and will require prior approval by the Contracting Officer.

A WARD RESUL Tll\k:3 FROM THIS soucrr A TION IS SUBJECT TO RECEIPT OF CONGRESSIONA UFRESIDENTIAL A f=FROVA L OF THE FY 21 NATIONAL DEFENSE AUTHORIZATION ACT AND FY21 MILITARY CONSTRUCTION QUALITY OF LIFE AND VETERANS AFFAIRS AFPROffilA TIONS ACT.

11. The Contractor shall begin perfor11T0nce within 15 calendar days and complete it w ithfn 760 calendar days after receiving

Daw ard, 0 notice to proceed. T his perforrrance period is D rrandatory, D negotiable. (See D:lcument 00700 .)

12 A. THE CONTRACTOR MUST FURNISH Am REQUIRBD !=£RFORMANCE AND PAY MENr BONDS? 12B. CALENDAR DAYS (If "YES,· indicate v.ithin how many calendar days after award in Item 12B.)

GYES □NO

13. ADDITIONAL SOLICITATION REQUIREM8'1TS:

A. Sealed offers in original and 3 copies to perform the w ork required are due at the place specified in Item 8 by 02:00 PIV1 (hour) local time See Doc 00100 (date). If this is a sealed bid solicitation, offers rrust be publicly opened at that tirre. Sealed envelopes containing offers shall be rrarked to show the offeror's narre and address, the solicitation number, and the date and tirre offers are due.

B. An offer guarantee Gis, 0 is not required.

C. All offers are subject to the (1) work requirerrents, and (2) other provisions and clauses incorporated in the solic�ation in full text or by reference.

D. Offers providing less than 150

NSN 7540-01-155-3212

calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.

1442-101 STANDARD FORM 1442 (Rel. 4-85) Prescribed byGSo\

F A

R (48CFR) 53.zl6.1(e)

SOLICITATION, OFFER AND AWARD (SF 1442), CONTINUED

PRICE PROPOSAL SCHEDULE

FOR

RFP NO. N62742-21-R-1334

J-023 BACHELOR OFFICER QUARTERS-A

SF1442 (continued)

ITEM

NO. DESCRIPTION

QTY

UNIT OF

ISSUE

UNIT

PRICE

AMOUNT

0001AA BASE ITEM: The basis for CLIN 0001AA is the price for all labor, material, and equipment for the entire work for WON 972483 complete and in accordance with the drawings and specifications, but not including any other CLIN/SLIN.

Lump Sum

0001AB MEC CLEARANCE

The basis for CLIN 0001AB is the price to perform full clearance ahead of construction for Munitions and Explosives of Concern (MEC)/Material Potentially Presenting an Explosive Hazard (MPPEH) for areas as shown on the attached maps, but not including any other CLIN/SLIN

0.2

Acres of

MEC/MPPEH

Clearance

$_________/acre

TOTAL CLIN 0001 $__________________

0002 PLANNED MODIFICATION:

FURNITURE, FIXTURES AND

EQUIPMENT (FF&E)

000201 Planned Modification: FF&E

Govt Est Amt

$7,038,500.00

000202 Handling and Administrative Rate (HAR)

NTE 5%

TOTAL CLIN 0002 $___________________

TOTAL EVALUATED PRICE (CLINS

0001 – 0002)

NOTES:

1. The Offeror SHALL include a price for all CLINs/SLINs. ALL OR NONE OFFERS - Offers are solicited on an

“all or none” basis and FAR 52.215-1, INSTRUCTIONS TO OFFERORS-COMPETITIVE ACQUISITION in Document 00100, is hereby modified. Failure to submit offers for all line items listed shall be cause for rejection of the offer.

2. Multiple awards will not be made.

3. The total of CLINs 0001 and 0002, total evaluated price, will form the basis for the price evaluation.

4. The Government intends to award CLIN 0001 only. CLIN 0002 will be awarded as noted in paragraph 7 below.

5. For SLIN 0001AB: In the event there is a difference between a unit price and the extended total, the unit price will be held to be the intended offer and the total will be recomputed accordingly. In an offer provides a total but fails to enter a unit price, the total divided by the specified quantity will be held to be the intended unit price.

SOLICITATION, OFFER AND AWARD (SF 1442), CONTINUED

PRICE PROPOSAL SCHEDULE

FOR

RFP NO. N62742-21-R-1334

J-023 BACHELOR OFFICER QUARTERS-A

SF1442 (continued)

6. For SLIN 000202: For evaluation purposes only, in the event of a discrepancy between the extended price for the HAR and the actual calculation of the HAR percentage proposed multiplied by the Government Estimated Amount, the Government will use the percentage proposed and will adjust your proposal accordingly.

7. The following notes apply to CLIN 0002 for Furniture, Fixtures and Equipment (FF&E):

a. Government Estimated Amount for FF&E. The Government Estimated Amount for FF&E, as shown above (CLIN 000201), includes the material cost, freight and installation charges. The Government Estimated Amount has been identified to provide Offerors with the projected magnitude of effort for FF&E. The total CLIN 0002 amount shall include all costs to procure, install and store the Furniture Fixtures and Equipment and includes the Prime Contractor’s proposed Handling and Administrative Rate (HAR).

b. Prime Contractor Handling and Administration Rate (HAR). Offerors may propose a HAR fee in CLIN 000202, up to but not to exceed 5%, for the handling and administration of the FF&E. This fee will account for all administrative costs;

overhead; bonding fees, if any; administration of subcontractors; profit; and any other costs associated with and related to the coordination and processing of the procurement and installation of the FF&E. The prime contractor’s proposed HAR mark-up will be applied to the Government Estimated Amount to derive a total proposed price for CLIN 0002.

c. The prime contractor’s HAR percentage rate will be incorporated into the contract as proposed and will not be adjusted regardless of fluctuations in the Government Estimated Amount. The HAR is a fixed percentage rate that will be utilized in calculating the final price for the planned modification. When the final FF&E package is priced, the contractor’s proposed HAR percentage rate, as incorporated into the contract, will be applied to the selected supplier/vendor’s quote to arrive at a total proposed price for final negotiation of the planned modification.

d. It is anticipated that a planned modification will be awarded at least six months prior to the completion of the work. The planned modification will be issued after receipt of appropriate funding. A minimum of six months is required for the contractor to purchase, deliver and install the FF&E without impacting the overall completion date of the project. No schedule extensions will be granted if the planned modification is awarded at least six months prior to the contract completion date. If the Government decides to negotiate and award the planned modification less than six months prior to the contract completion date, the contractor may be entitled to a contract extension.

8. DFARS 252.247-7023, TRANSPORTATION OF SUPPLIES BY SEA. Within 30 days of each shipment, the Contractor is required to provide an electronic copy of the carrier’s bill of lading to the Contracting Officer and to MARAD via email. MARAD email: mark.e.williams@dot.gov. In addition, the Contractor shall notify the Contracting Officer when oceanic shipments have been initiated within 3 working days of shipment.

CU101

BOQ A BLDG

UTILITY BLDG

SCALE:

J-023 UTILITY SITE PLAN 11:500

PAVILION

TRASH ENCLOSURE

AND RECYCLING

NOTES:

1. EXISTING SITE FEATURES ARE CONCEPTUAL. THE EXISTING SITE

FEATURES ARE BASED UPON THE FINAL DESIGN FOR PROJECT

J-001B.

2. VERIFY LOCATION AND INVERT OF EXISTING UTILITIES PRIOR TO

CONSTRUCTION.

3. UNLESS FEATURES ARE IDENTIFIED FOR REMOVAL, THE

FEATURES MUST REMAIN. PROTECT EXISTING FEATURES TO

REMAIN.

4. REFER TO PLUMBING, MECHICAL, AND FIRE PROTECTION

DRAWINGS FOR CONTINUATION.

5. REFER TO CU201 - CU202 FOR WATER PROFILES. ALL WATER

MAINS MUST HAVE A MINIMUM OF 750mm DEPTH OF COVER.

6. REFER TO CU203 FOR SANITARY SEWER PROFILES.

7. FOR UTILITIES NOT PROFILED, REFER TO CROSSING UTILITY

PROFILES FOR FOR SEPARATION AT CROSSING.

8. PROVIDE THRUST BLOCK AT VERTICAL AND HORIZONTAL BENDS

OF WATER LINES. REFER TO DETAIL 1/CU502.

9. REFER TO CU504 FOR PIPE BEDDING SECTION.

10. REFER TO CU603 FOR WATER APPURTENANCE SCHEDULE.

11. REFER TO CU604 FOR SANITARY SEWER STRUCTURE SCHEDULE.

12. REFER TO ES101 FOR ELECTRICAL SITE PLANS.

13. REFER TO T-100 FOR TELECOMMUNICATIONS SITE PLAN.

14. ALL PIPE SLOPES 0.004mm EXCEPT SERVICE LATERAL IS 0.01mm.

ALL DIMENSIONS AND/OR DIMENSIONS SHOWN

IN CALLOUT/NOTES ARE IN METERS UNLESS

OTHERWISE NOTED.

SEE NOTE 12

SEE NOTE 13

PLAN

NORTH

PLAN

NORTH

SEE NOTE 4

SSWR

MH16

SSWR MH14

SSWR MH12

SSWR MH11

SSWR MH12

KEYNOTES:

1 PROVIDE 300mm FUSIBLE PVC C-900 DR 18 DOMESTIC WATER SERVICE LINE

2 PROVIDE 250mm FUSIBLE PVC C-900 DR 18 DOMESTIC WATER SERVICE LINE

3 PROVIDE 400mm FUSIBLE PVC C-900 DR 18 DOMESTIC WATER SERVICE LINE

4 PROVIDE 250mm X 200mm REDUCER

5 HOSE BIB

6 PROVIDE 40mm FUSIBLE PVC ASTM D-1785 SCH 40 DOMESTIC WATER

SERVICE LINE WITH WATER METER, SEE DETAIL C/CU502

7 PROVIDE 150mm FIRE WATER SERVICE LINE

8 PROVIDE FIRE HYDRANT ASSEMBLY, SEE DETAIL 4/CU504

9 PROVIDE POST INDICATOR VALVE, SEE DETAIL 5/CU503

10 FIRE DEPARTMENT CONNECTION, SEE DETAIL 1/CU504

11 PROVIDE 200mm PVC SDR 35 SANITARY SEWER SERVICE LINE

12 PROVIDE 150mm PVC SDR 35 SANITARY SEWER SERVICE LINE

13 PROVIDE SANITARY SEWER MANHOLE, SEE DETAIL 2/CU503

14 PROVIDE SANITARY SEWER CLEANOUT, SEE DETAIL 1/CU503

15 PROVIDE DOUBLE SANITARY SEWER CLEANOUT

16 PCC ENCASEMENT, SEE DETAIL 3/CU502

17 WATER LINE 3 (200mm PVC)

18 MH2B-3

19 WATER LINE 2 (300mm PVC)

20 WATER LINE 2 (300mm PVC)

21 UTILITY CORRIDOR, SEE DETAIL 6/CU503

22 UTILITY CORRIDOR, SEE DETAIL 4/CU502

23 PROVIDE 100mm PVC SDR 35 SANITARY SEWER SERVICE LINE

24 PROVIDE SANITARY SEWER MANHOLE DROP CONNECTION, SEE DETAIL

3/CU503

25 PROVIDE GATE VALVE SEE DETAIL 6/CU501

26 PROVIDE COMBINATION AIR VALVE SEE DETAIL 1/CU505

WTR LTRL (200mm PVC)

STA 1+290.500

INV =139.950

STA 1+108.250

RIM 139.619

200mm INV IN: 137.839

SLOPE IN 0.514%

250mm INV OUT: 137.789

SLOPE OUT 2.833%

WTR LTRL (200mm PVC)

STA 1+986.000

INV =137.900

WTR LTRL (200mm PVC)

STA 1+916.000

INV = 139.139

4 17

SSWR MH09 13

SSWR MH14

SSWR MH01

SSWR MH02

13SSWR

MH18

13SSWR MH17

SEE

NOTE 4

J-023 SSWR LINE C

5 68

SSWR MH03

BIKE PAVILLION

J-023 SSWR LINE A

J-023 WATR LINE B

J-023 MECH LINE TO VALVE PIT

13 SSWR MH04

SSWR MH05

13 SSWR MH08

BBQ PAVILION

5 6

PAVILION

J-023 SSWR LINE B

J-023 WATR LINE C

J-023 SSWR LINE A

J-023 MECH LINE

J-023 FIRE WATER LINE A

SEE NOTE 1216

J-023 WATR LINE A

J-023 WATR LINE A

13 SSWR MH13

J-023 WATR LINE A

J-023 VALVE PIT FOR

DISTRICT PLANT

J-023 FIRE WATER LINE B

SEE NOTE 13

SSWR MH06

5 6

13 SSWR MH13

Polygonal Line

Polygonal Line

Polygonal Line

Polygonal Line

Polygonal Line

Polygonal Line

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

2+990 3+000 3+020 3+040 3+060 3+080 3+100

EG FG

3+000

3.

3.

3+020

2.

3.

3+040

2.

3.

3+060

1.

3.

3+080

150mm FIRE PIPE 03 L=11m S=4.29%

WATR PIPE 25

CHWS PIPE 02

CHWR PIPE 02

HWS PIPE 02

HWR PIPE 02

PROPOSED GRADE

EXISTING GRADE

150mm FIRE PIPE 01 L=1m S=4.24%

150mm FIRE PIPE 02

L=22m S=4.29%

150mm FIRE PIPE 04 L=21m S=0.34%

150mm FIRE PIPE 05 L=19m S=0.34%

0.

0.

CW PIPE 02

HWR PIPE 05

HWS PIPE 05

CHWR PIPE 05

CHWS PIPE 05

0.

FA 2

FA 1

FA 3

PIV

FA 4 FA 5 FA 6 HHWR PIPE 02

HHWS PIPE 02

WATR PIPE 28

WATR PIPE 30

0.

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

2+490 2+500 2+520 2+540 2+560 2+580

EG FG

2+500

1.

3.

2+520

1.

2.

2+540

2.

2.

2+560

PROPOSED GRADE

EXISTING GRADE

250mm WATR PIPE 19

L=15m S=6.97%

250mm WATR PIPE 20

L=29m S=3.18%

WA 19

WA 20

WA 21

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

3+190 3+200 3+220 3+240 3+250

EG FG

3+200

3.

3.

3+220

3.

3.

3+240

PROPOSED GRADE

EXISTING GRADE

150mm FIRE PIPE 08 L=29m S=4.84%

150mm FIRE PIPE 07 L=2m S=22.78%

150mm FIRE PIPE 06 L=5m S=13.32%FA 7

FA 8

FA 9

FA 10

HWR PIPE 06

HWS PIPE 06

CHWR PIPE 06

CHWS PIPE 06

0.

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

1+990 2+000 2+020 2+040 2+060 2+080 2+100 2+120 2+130

EG FG

2+000

8.

0.

2+020

9.

1.

2+040

9.

1.

2+060

0.

1.

2+080

0.

2.

2+100

0.

2.

2+120

300mm WATR PIPE 02 L=22m S=0.65%

PROPOSED GRADE

EXISTING GRADE

1.

300mm WATR PIPE 43 L=18m S=0.22%

300mm WATR PIPE 47

L=69m S=4.42%

SSWR PIPE 01

WA 43

WA 45

WA 2

WA 6

WA 47 GATE VALVE

WA 44 GATE VALVE

300mm WATR PIPE 46 L=1m S=4.42%

300mm WATR PIPE 44 L=1m S=0.22%

SDP-02E

1.

300mm WATR PIPE 03 L=8m S=0.66%

WA 3

CU201

VERTICAL

ALL DIMENSIONS AND/OR DIMENSIONS SHOWN

IN CALLOUT/NOTES ARE IN METERS UNLESS

OTHERWISE NOTED.

HORIZONTAL

SCALE:

J-023 FIRE WATER LINE A PROFILE 1H 1:500, V 1:50

NOTES:

1. SEE SHEETS CU605 - CU606 FOR PIPE AND APPURTENANCE

SCHEDULES.

SCALE:

J-023 FIRE WATER LINE B PROFILE 2H 1:500, V 1:50

SCALE:

J-023 WATER LINE A PROFILE 3H 1:500, V 1:50 SCALE:

J-023 WATER LINE B PROFILE 3H 1:500, V 1:50

Distance Measurement

4.73 in

Distance Measurement

1.55 m

Distance Measurement

2.19 m

Distance Measurement

1.31 m

Distance Measurement

1.29 m

Distance Measurement

1.24 m

Distance Measurement

1.46 m

Distance Measurement

1.08 m

Distance Measurement

1.04 m

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

3+990 4+000 4+020 4+040 4+060 4+080 4+100

EG FG

4+000

1.

3.

4+020

1.

3.

4+040

1.

2.

4+060

2.

2.

4+080

PROPOSED GRADE

EXISTING GRADE

200mm CHWR PIPE 03 L=27m S=2.60%

WATR PIPE 22

0.

200mm CHWR PIPE 01 L=2m S=2.50%

200mm CHWR PIPE 02 L=13m S=2.59%

0.

200mm CHWR PIPE 04 L=26m S=3.67%

FIRE PIPE 05

UCA 04

UCA 11

UCA 18

UCA 25

UCA 32

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

PROFILE VIEW OF J-023 WATR LINE C

2+190 2+200 2+220 2+240 2+260 2+280 2+300 2+320 2+340 2+360 2+380 2+400 2+420 2+440 2+460 2+480 2+500 2+520 2+540

EG FG

0.

2+200

1.

2.

2+220

1.

2.

2+240

2.

2.

2+260

2.

2.

2+280

3.

2.

2+300

3.

3.

2+320

3.

3.

2+340

3.

3.

2+360

2.

2.

2+380

2.

2.

2+400

1.

3.

2+420

1.

3.

2+440

0.

2.

2+460

0.

2.

2+480

9.

2.

2+500

9.

1.

2+520

9.

0.

300mm WATR PIPE 42 L=20m S=0.34% 300mm WATR PIPE 37

L=27m S=0.58%

300mm WATR PIPE 36 L=9m S=0.58%

300mm WATR PIPE 31 L=36m S=1.38%

300mm WATR PIPE 26 L=10m S=0.15% 300mm WATR PIPE 24

L=6m S=3.53%

300mm WATR PIPE 25 L=10m S=2.80%

300mm WATR PIPE 12

L=22m S=4.60%

300mm WATR PIPE 09 L=4m S=2.64%

300mm WATR PIPE 07 L=8m S=2.64%

300mm WATR PIPE 06 L=40m S=2.48%

300mm WATR PIPE 22 L=7m S=2.48%

CHWS PIPE 03 CHWR PIPE 03

HWS PIPE 03

HWR PIPE 03

SSWR PIPE 09

PROPOSED GRADE

EXISTING GRADE

0.

CW PIPE 03

300mm WATR PIPE 32 L=3m S=0.01%

WA 43

WA 41

WA 36

WA 37

WA 30

WA 32

WA 19

WA 23

WA 25

WA 26

WA 7

WA 8

WA 10

WA 6

HHWR PIPE 03

HHWS PIPE 03

WA 22 GATE VALVE

WA 24

COMBINATION AIR RELEASE VALVE

WA 18 GATE VALVE

300mm WATR PIPE 23 L=1m S=2.48%

300mm WATR PIPE 21 L=1m S=2.47%

300mm WATR PIPE 18 L=1m S=4.75%

300mm WATR PIPE 17

L=31m S=4.80%

WA 13

WA 27

300mm WATR PIPE 29 L=9m S=0.19%

WA 33

300mm WATR PIPE 35 L=27m S=0.62%

300mm WATR PIPE 40 L=53m S=0.58%

WA 38

SDP-02E

1.

FIRE PIPE 06

0.

FIRE PIPE 05

0.

PROPOSED GRADE

EXISTING GRADE

SSWR PIPE 32WA 48

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

4+190 4+200 4+220 4+240 4+260 4+270

EG FG

4+200

2.

3.

4+220

3.

3.

4+240

3.

3.

4+260

200mm CHWR PIPE 07 L=39m S=2.78%

200mm CHWR PIPE 06 L=12m S=2.25%

200mm CHWR PIPE 05 L=2m S=2.15%

FIRE PIPE 06

FIRE PIPE 02

0.

0.

UCA 37

UCA 41

UCA 45

UCA 49

PROPOSED GRADE

EXISTING GRADE

WATR PIPE 33

0.

0.

WATR PIPE 48

CU202

VERTICAL

ALL DIMENSIONS AND/OR DIMENSIONS SHOWN

IN CALLOUT/NOTES ARE IN METERS UNLESS

OTHERWISE NOTED.

HORIZONTAL

SCALE:

J-023 WATER LINE C PROFILE 1H 1:500, V 1:50

NOTES:

1. SEE SHEETS CU603 - CU606 FOR PIPE, STRUCTURE, AND

APPURTENANCE SCHEDULES

SCALE:

J-023 MECH LINE PROFILE 2H 1:500, V 1:50 SCALE:

J-023 MECH LINE TO VALVE PIT PROFILE 3H 1:500, V 1:50

Distance Measurement

2.15 m

Distance Measurement

2.57 m

Distance Measurement

1.12 in

1.19 in�

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

1+680 1+700 1+720 1+740 1+760 1+780 1+800 1+820 1+840 1+860 1+880 1+900 1+920 1+940 1+960

EG FG

1+700

0.

2.

1+720

0.

2.

1+740

0.

2.

1+760

1.

2.

1+780

1.

2.

1+800

2.

2.

1+820

2.

2.

1+840

3.

3.

1+860

3.

3.

1+880

3.

3.

1+900

2.

2.

1+920

2.

2.

1+940

200mm SSWR PIPE 14

L=28m S=1.00%

SS

W

R M

H

ST

A:

1+

8.

R

IM

:1

.1

N

IN

V.

IN

:1

.2

E

IN

V.

IN

:1

.7

S

IN

V.

O

U T:

9.

D

R O

P C

O N

N

EC

TI

O

N

SS

W

R M

H

ST

A:

1+

5.

R

IM

:1

.3

E

IN

V.

IN

:1

.5

S

IN

V.

O

U T:

9.

SSWR MH12

STA: 1+809.359

RIM: 142.934

E INV. IN: 140.130

S INV. IN: 141.576

W INV. OUT: 140.104

1 DROP CONNECTION

SSWR MH13

STA: 1+849.933

RIM: 143.072

SE INV. IN: 140.562

W INV. OUT: 140.536

SSWR MH14

STA: 1+855.566

RIM: 143.421

S INV. IN: 140.644

NW INV. OUT: 140.618

SSWR MH15

STA: 1+864.926

RIM: 143.303

S INV. IN: 140.764

W INV. IN: 141.926

N INV. OUT: 140.738

1 DROP CONNECTION

SSWR MH16

STA: 1+878.931

RIM: 143.098

W INV. IN: 140.930

N INV. OUT: 140.904

200mm SSWR PIPE 26 L=45m S=1.00%

SS

W

R M

H

ST

A:

1+

3.

R

IM

:1

.9

N

IN

V.

IN

:1

.5

E

IN

V.

O

U T:

1.

SS

W

R M

H

ST

A:

1+

6.

R

IM

:1

.4

S

IN

V.

IN

:1

.1

N

IN

V.

IN

:1

.9

E

IN

V.

IN

:1

.2

W

IN

V.

O

U T:

8.

EXISTING GRADE

PROPOSED GRADE

200mm SSWR PIPE 16 L=14m S=1.00%

200mm SSWR PIPE 18 L=13m S=1.00%

200mm SSWR PIPE 19 L=54m S=1.00%

200mm SSWR PIPE 22 L=6m S=1.00%

200mm SSWR PIPE 21

L=41m S=1.00%

200mm SSWR PIPE 23 L=9m S=1.00%

200mm SSWR PIPE 25 L=14m S=1.00%

SSWR MH10

STA: 1+742.483

RIM: 142.889

N INV. IN: 139.410

E INV. IN: 141.602

S INV. OUT: 139.384

1 DROP CONNECTION

EXISTING GRADE

PROPOSED GRADE

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

1+780 1+800 1+820 1+840 1+860 1+880

EG FG

1+800

0.

2.

1+820

1.

2.

1+840

1.

2.

1+860

PROPOSED GRADE

EXISTING GRADE

SS

W

R M

H

ST

A:

1+

5.

R

IM

:1

.9

E

IN

V.

IN

:1

.3

W

IN

V.

IN

:1

.3

S

IN

V.

O

U T:

1.

100mm SSWR PIPE 09 L=52m S=1.00%

0.

SS

W

R C

O

ST

A:

1+

1.

R

IM

:1

.1

W

IN

V.

O

U T:

1.

WATR PIPE 17

EL

EV

AT

IO

N

EL

EV

AT

IO

N

STATION

STATION

0+980 1+000 1+020 1+040 1+060 1+080 1+100 1+120 1+140 1+160 1+180

EG FG

1+000

9.

9.

1+020

0.

2.

1+040

9.

2.

1+060

9.

2.

1+080

9.

2.

1+100

9.

2.

1+120

0.

2.

1+140

0.

3.

1+160

PROPOSED GRADE

EXISTING GRADE

200mm SSWR PIPE 01 L=17m S=0.80%

SSWR MH02

STA: 1+073.209

RIM: 141.218

E INV. IN: 138.592

N INV. OUT: 138.566

SSWR MH03

STA: 1+085.788

RIM: 142.543

E INV. IN: 140.521

N INV. IN: 141.609

W INV. OUT: 139.410

2 DROP CONNECTIONS

SS

W

R M

H

ST

A:

1+

7.

R

IM

:1

.2

N E

IN

V.

IN

:1

.6

W

IN

V.

O

U T:

0.

200mm SSWR PIPE 07 L=22m S=0.48%

SS

W

R M

H

ST

A:

1+

5.

R

IM

:1

.9

E

IN

V.

IN

:1

.3

W

IN

V.

IN

:1

.3

S

IN

V.

O

U T:

1.

200mm SSWR PIPE 03

L=57m S=0.80%

200mm SSWR PIPE 04 L=13m S=6.50%

200mm SSWR PIPE 06 L=12m S=1.00%

200mm SSWR PIPE 30 L=7m S=1.00%

SSWR MH05

STA: 1+104.217

RIM: 142.786

N INV. IN: 140.757

SW INV. OUT: 140.731

WATR PIPE 47

SS

W

R M

H

ST

A:

1+

6.

R

IM

:1

.4

S

IN

V.

IN

:1

.1

N

IN

V.

IN

:1

.9

E

IN

V.

IN

:1

.2

W

IN

V.

O

U T:

8.

D

R O

P C

O N

N

EC

TI

O

N S

1.

INV. 137.954

SSWR MH06

STA: 1+126.257

RIM: 142.978

N INV. IN: 140.888

S INV. OUT: 140.862

200mm SSWR PIPE 31 L=29m S=1.39%

CU203

VERTICAL

ALL DIMENSIONS AND/OR DIMENSIONS SHOWN

IN CALLOUT/NOTES ARE IN METERS UNLESS

OTHERWISE NOTED.

HORIZONTAL

SCALE:

J-023 SSWR LINE B PROFILE 3H 1:500, V 1:50

SCALE:

J-023 SSWR LINE C PROFILE 2H 1:500, V 1:50

NOTES:

1. SEE SHEET CU603 FOR PIPE AND APPURTENANCE SCHEDULES.

SCALE:

J-023 SSWR LINE A PROFILE 1H 1:500, V 1:50

Distance Measurement

2.15 m

Distance Measurement

3.35 m

Distance Measurement

1.20 in

Distance Measurement

1.13 in

1.22 m

SDSDSD

W

W

SAN

W

W W

W

WWWWWW

W

W

W W

W W

W W

W W

WWWWW

W W

W W

W W

W W

W W

W W

W

W W W W W W W W W W W

S A

N S

A N

S A

N

SAN

S A

N S

A N

S A

N S

A N

S A

N S

A N

S A

N

SAN SAN SAN SAN SAN SAN

S A

N

SANSAN

W W W W

W

W

W

W

SAN SAN SAN

W W

W W W W W

W W

W W W W W

W W

W W W W W

W

W W W W W W

W

W W W W W W

W

W W W W W W

W

W W W W W W

F

F F F

W W

W W

W

W W

W W

W

W W

W W

W

W W

W W

W

W

WW

SANSAN

W

R O

A D

R O

A D

MH-579-10B

BOQ A BUILDING

SHH-2

SHH-1

E

S

E

E

ES

E S

ES

E

S

E S

ES

UTILITY BUILDING

PAVILION

PAVILION

E

S

E S

E

S

E

S

E S

ES

ES

E

S

E S

ES ES

10 10

SHH-1

E

S

E

S

E

S

E S

ES

ES

ES

ES

E

S

E

S

E

S

E

S

E

S

ES

E

S

E S

E

S

E

S

E

S

E

S

E

S

E

S

E S

E

S

E

S

E

S

ES

E

S

E S

E

S

E

S

E

S

E

S

E

S

E

S

E S

E

S

E

S

E S

E

S

E

S

E S

SDSDSD

R O

AD

ROAD 3

(E) ST P574A-18

(E) ST P579-10

(E) MH P574A-18

(E) MH P579-10

MH P579-10A

(E) MH P574-17

(E) MH P579-10A

SWITCHBOARD "4MDS-BB"

PAD MOUNTED TRANSFORMER "UA"

PAD MOUNTED TRANSFORMER "BA"

E-404

FOR ENLARGED PLAN, SEE & .

E-404

E-404

FOR ENLARGED PLAN, SEE & .

E-404

TYPICAL

BOQ A - ELECTRICAL SITE PLAN

ALL DIMENSIONS AND/OR DIMENSIONS SHOWN IN

CALLOUT/ NOTES ARE IN MILLIMETERS UNLESS

OTHERWISE NOTED.

PLAN

NORTH

KEY PLAN

NOT TO SCALE

ES101

TO SWITCHBOARD "4MDS-UB"

L

TYPICAL

M

TO ECB-EMB AND ECB-GBB

TO GENERATOR WIRE GUTTER

BOQ A BUILDING AMI METER

CT CABINET

P P

SP SP

P P SP

E-404

FOR ENLARGED PLAN, SEE & .

E-404

4L1L-8

VIA LC "LC-EL"

4L1L-10

VIA LC "LC-EL"

4L1L-11

VIA LC "LC-EL"

BBQ PAVILION

E-104

FOR ENLARGED PLAN, SEE & .

E-124

P P SP

P

P P

SP SP

TO ATS-GUB

S

S

S S S

S

GENERAL NOTES:

SEE ONE LINE DIAGRAM E-601 AND E-602 FOR CONDUIT AND WIRE SIZES AND

QUANTITIES.

LIGHT LINES INDICATE INFRASTRUCTURE CONSTRUCTED UNDER J-001B

FINEGAYAN UTILITIES AND SITE IMPROVEMENTS PHASE 1 PROJECT. DARK

LINES INDICATE NEW.

B O

Q A

E

LE

C

TR

IC

A L

S

IT

E P

LA

N

ES101

4L1L-12

VIA LC "LC-EL"

4L1L-9

VIA LC "LC-EL"

S

S S S

S

SP SP

S

27mmC, FOR AMI METER POWER

SP SP

S S S

S S S

TO PANEL "2L1P"

S S S

S

SP SP

S S

S S

S S S

S S

S S S

S

SP

S

SP

S SS

S S

S S S

S

SP

S

SP

S SS

S S S

S S S

D E P A R

TM

E N T O F

TH

E

N A V Y

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

NAVFAC DRAWING NO.

N A V F A C

F A C

IL

IT

IE

S

E N G

IN

E E R

IN

G

C O M M A N D

P A C

IF

IC

DES DRW

S Y M

D E S C R I P T I O N

D A T E

A P P R

DRAWFORM REVISION: 30 APRIL 2015

REV

SATISFACTORY TO

APPROVED

ACTIVITY

DATE

FOR COMMANDER NAVFAC

A/E INFO

EPROJECT NO.:

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

N A

VF

A

C P

A C

IF

IC

M A K A L A P A

H A W A I I

FIRE PROTECTION

AS SHOWN

UNCLASSIFIED - FOR OFFICIAL USE ONLY

UNCLASSIFIED - FOR OFFICIAL USE ONLY

R E V D A T E

P L O T T E D

U N C L A S S I F I E D

F O R

O F F I C I A L

U S E

O N L Y

P R

E L

IM

IN

A

R Y

N O

T

FO

R C

O N

ST

RU

C

TI

O N

N A V F A C

P A C I F I C

XX/XX/XXXX

SEAL

GU

AM

US

N

AV

SU

PP

AC

T M

CB

G

UA

M

JF

Y

J

-0

B A

C H

E

LO

R O

FF

IC

E R

Q U

A R

TE

R

S -A

THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK

AMONG THE VARIOUS TRADES AS NECESSARY TO AVOID CONFLICTS AND TO

INSURE THE INSTALLATION OF ALL WORK WITHIN THE AVAILABLE SPACE.

DATE

IF SHEET IS LESS THAN 559 X 864

REDUCED PRINT. USE GRAPHIC

SCALES

JC

P. NISHIZAKI

MN/KO

972483

XXX

RANDALL TORIGOE

MARFORPAC DPRI MILCON LEAD

JJ/JF RS/NP AM

JS

SP SP

S S

VIA CT CABINET, SEE ONE LINE DIAGRAM FOR INFORMATION.

NOTES:

TO PAVILION LIGHTING.2

TO PAVILION RECEPTACLE.3

4L1L-132L1P-27

AutoCAD SHX Text

SCALE: 1:500

AutoCAD SHX Text

AutoCAD SHX Text 1:500

AutoCAD SHX Text 10m

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text A

AutoCAD SHX Text N

AutoCAD SHX Text O

AutoCAD SHX Text A

AutoCAD SHX Text B

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text

(ELECTRICAL)

AutoCAD SHX Text No. 1259

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text I

AutoCAD SHX Text F

AutoCAD SHX Text I

AutoCAD SHX Text T

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text C

AutoCAD SHX Text M

AutoCAD SHX Text A

AutoCAD SHX Text U

AutoCAD SHX Text G

AutoCAD SHX Text

EXP.

AutoCAD SHX Text V.

AutoCAD SHX Text April 30, 2021

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Rectangle

EMCE

Polygon

N62742-21-R-1334

DOCUMENT 00100 TABLE OF CONTENTS

DOCUMENT 00100

INSTRUCTIONS TO PROPOSERS

9/20

1.1 NUMBER OF COPIES/TIME OF RECEIPT

1.2 INSTRUCTION FOR OBTAINING THE REQUEST FOR PROPOSAL

1.3 INSTRUCTIONS FOR SUBMITTING QUESTIONS REGARDING SOLICITATION

1.4 AMENDMENTS

1.5 PREAWARD SURVEY/RESPONSIBILITY DETERMINATION

1.6 PARTNERSHIPS, JOINT VENTURES (JV), LIMITED LIABILITY COMPANIES (LLC), LIMITED

PARTNERSHIPS (LP), ETC.

1.7 SUBCONTRACTING PLAN

1.8 FAR 52.204-7, SYSTEM FOR AWARD MANAGEMENT (OCT 2018)

1.9 FAR 52.204-16, COMMERCIAL AND GOVERNMENT ENTITY REPORTING (AUG 2020)

1.10 FAR 52.211-6, BRAND NAME OR EQUAL (AUG 1999)

1.11 FAR 52.211-14, NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY

PREPAREDNESS, AND ENERGY PROGRAM USE (APR 2008)

1.12 FAR 52.214-34, SUBMISSION OF OFFERS IN THE ENGLISH LANGUAGE (APR 1991)

1.13 FAR 52.214-35, SUBMISSION OF OFFERS IN U.S. CURRENCY (APR 1991)

1.14 FAR 52.215-1, INSTRUCTIONS TO OFFERORS--COMPETITIVE ACQUISITION (JAN 2017)

1.15 FAR 52.216-1, TYPE OF CONTRACT (APR 1984)

1.16 FAR 52.217-5, EVALUATION OF OPTIONS (JUL 1990)

1.17 FAR 52.222-5, CONSTRUCTION WAGE RATE REQUIREMENTS—SECONDARY SITE OF THE

WORK (MAY 2014)

1.18 FAR 52.222-23, NOTICE OF REQUIREMENT FOR AFFIRMATIVE ACTION TO ENSURE EQUAL

EMPLOYMENT OPPORTUNITY FOR CONSTRUCTION (FEB 1999)

1.19 FAR 52.225-12, NOTICE OF BUY AMERICAN REQUIREMENT--CONSTRUCTION MATERIALS

UNDER TRADE AGREEMENTS (MAY 2014) ALTERNATE I (MAY 2014), ALTERNATE II (JUN 2009)

1.20 FAR 52.233-2, SERVICE OF PROTEST (SEP 2006)

1.21 FAR 52.236-27, SITE VISIT (CONSTRUCTION) (FEB 1995)

1.22 FAR 52.236-28, PREPARATION OF PROPOSALS--CONSTRUCTION (OCT 1997)

1.23 DFARS 252.204-7008, COMPLIANCE WITH SAFEGUARDING COVERED DEFENSE INFORMATION

CONTROLS (OCT 2016)

1.24 DFARS 252.215-7008, ONLY ONE OFFER (JUL 2019)

1.25 DFARS 252.215-7010, REQUIREMENTS FOR CERTIFIED COST OR PRICING DATA AND DATA

OTHER THAN CERTIFIED COST OR PRICING DATA – BASIC (JUL 2019)

1.26 TERRITORY OF GUAM NOTICE CONCERNING TAXES, LICENSES, WITHHOLDINGS

1.27 GOVERNMENT OF JAPAN OBSERVERS

1.28 ALTERNATIVE MATERIALS

--End Document Table of Contents--

N62742-21-R-1334

DOCUMENT 00100

INSTRUCTIONS TO PROPOSERS

9/20

1.1 NUMBER OF COPIES/TIME OF RECEIPT

a. PRICE PROPOSAL (PAPER): An original paper and one (1) paper copy of the price proposal shall be submitted on 17 February 2021, 2:00 p.m., H.S.T. in a sealed envelope and marked in the bottom right corner "PRICE PROPOSAL SUBMITTED UNDER RFP N62742-21-R-1334 - DO NOT OPEN IN MAILROOM." The PRICE PROPOSAL shall include the following:

(1) Manually (wet signature) signed and completed SF 1442 (Solicitation, Offer and Award)(NOTE: SF1442

Block 14 shall include the offeror’s name and physical address exactly as shown in the System for Award Management registration. If mailing address is different from physical address, both addresses may be shown in Block 14, however both addresses shall be EXACTLY as shown in SAM)

(2) Signed and completed Bid Guarantee

(3) Representations and Certifications (See Document 00600)(COMPLETE ALL PROVISIONS)

(4) Information required by paragraph 1.5, Pre-Award Survey/Responsibility Determination

(5) Information required by paragraph 1.6, Partnerships, Joint Ventures (JV), Limited Liability Companies (LLC), Limited Partnerships (LP), Etc.

b. TECHNICAL: (FACTORS 1, 2, AND 3)(PAPER): An original paper and three (3) paper copies of the technical proposals shall be submitted on 17 February 2021, 2:00 p.m., H.S.T. in a sealed envelope/package/box and marked in the bottom right corner "TECHNICAL PROPOSAL SUBMITTED UNDER RFP N62742-21-R-1334

- DO NOT OPEN IN MAILROOM." Identify the original proposal as "Original" on the cover of the proposal. The TECHNICAL PROPOSAL shall be submitted in a three-ring binder with table of contents and tabbed. The TECHNICAL PROPOSAL shall include the following:

(1) All information required by Factor 1, Experience

(2) All information required by Factor 2, Past Performance

(3) All information required by Factor 3, Safety

c. SUBCONTRACTING PLAN (PAPER): An original paper and one (1) paper copy of the subcontracting plan shall be submitted by 18 February 2021, 2:00 p.m., H.S.T. in a sealed envelope/package/box and marked in the bottom right corner "SUBCONTRACTING PLAN SUBMITTED UNDER RFP N62742-21-R-1334 - DO NOT OPEN IN MAILROOM." Identify the original proposal as "Original" on the cover of the proposal.

(1) All information required by paragraph 1.7, Small Business Subcontracting Plan

d. PRICE AND TECHNICAL PROPOSALS (ELECTRONIC): An electronic copy of the price and technical proposals shall be submitted in .pdf format on a CD-ROM with the paper copy of the Small Business Subcontracting Plan. The offeror is responsible for ensuring that all original paper and electronic copies are identical. Should there be a discrepancy between the paper and electronic versions, the paper copy shall govern.

e. Proposals shall be submitted as follows:

(1) If sent via U. S. Postal Mail/Express Courier:

NAVAL FACILITIES ENGINEERING COMMAND, PACIFIC

N62742-21-R-1334

DOCUMENT 00100

Construction Contracts Branch (ACQ33) 258 Makalapa Drive, Suite 100 Pearl Harbor, HI 96860-3134

(2) If hand-carried (Delivery hours between 7:00 AM and 2:00 PM, Monday Through Friday except Federal Holidays)

NAVAL FACILITIES ENGINEERING COMMAND, PACIFIC

Construction Contracts Branch (ACQ33)

4256 Radford Drive, Building 62 (if facing the building office is on the right. DO NOT drop off at the Navy Federal Credit Union) Honolulu, HI 96818-3296

1.2 INSTRUCTION FOR OBTAINING THE REQUEST FOR PROPOSAL

The RFP can be accessed at https://beta.sam.gov. Printed copies of the RFP will not be issued. Contractors must register at the BETA System for Award Management (SAM) website https://beta.sam.gov to obtain access to the RFP documents. Registration instructions can be found on the BETA SAM website. Approved contractors may view and/or download the RFP documents. For proposal preparation purposes only, the Contracting Officer approves the release of the RFP drawings and specifications to subcontractors and suppliers who have the need-to-know.

1.3 INSTRUCTIONS FOR SUBMITTING QUESTIONS REGARDING SOLICITATION

Questions regarding the solicitation shall be submitted in writing in WORD format via electronic mail to Norine E.

Horikawa, norine.horikawa@navy.mil. Questions shall reference the drawing/detail and/or the specification section including paragraph number. Verbal queries will not be entertained. Responses to the questions will be provided in the form of a Notice and will be posted to the web site https://beta.sam.gov. The Government may not respond to questions submitted less than 10 days before the proposal receipt due date.

1.4 AMENDMENTS

Amendments will be posted to https://beta.sam.gov. It is highly recommended that firms register on the BETA SAM website as an interested vendor as this will be the only planholder’s list available. It is the offeror's responsibility to check the website periodically for any amendments to the solicitation.

1.5 PREAWARD SURVEY/RESPONSIBILITY DETERMINATION

FAR §9.104 requires prospective contractors to demonstrate, among other things, that they have adequate financial resources to perform the contract or the ability to obtain them, capability to comply with the required performance schedule, a satisfactory performance record, and be otherwise eligible to receive an award under applicable laws and regulations. The pre-award survey is not a part of the technical evaluation. The following information shall be submitted:

a. The offeror shall submit a document that appoints, in writing, one or more individuals, by name, each of whom will have full and independent authority to bind the offeror with respect to any act connected with this solicitation, including but not limited to: the submission and revisions of a proposal or proposals by the company, the conduct of discussion or negotiations, the submission of a Final Proposal Revision (FPR), and the execution of a contract and associated documents including bonds. Documents of appointment by a supporting resolution of the board of directors in the case of a corporation and by an instrument of similarly binding character in the case of an unincorporated entity. If bonds are not signed manually (wet signature), documents of appointment must include specific authorization and corporate approval for the use of electronic and facsimile signatures by the appointed individual(s).

b. Company financial statements (balance sheets and income statements) for past three years.

N62742-21-R-1334

c. Financial resources available to perform the contract. Submit evidence of availability of working/operating capital that will be used for the performance of the contract. If the offeror plans to rely on financial support from other sources, identify the maximum lines of credit that will be available to include documentation to support the amounts. The maximum lines of credit should be based upon the inclusion of this contract effort. For joint ventures discuss the financial responsibilities for each partner.

d. Newly-formed entities (e.g. limited liability companies (“LLC’s”), limited partnerships (“LTD’s”) and newly-created corporate subsidiaries) that is the entity liable for the contract ordinarily have no financial capability to support a responsibility determination. In such cases, the offeror may rely on the resources of the LLC member, parent, limited partner, or other entities related to the offeror for responsibility purposes where the offer submits a guaranty from the entity providing the resources. The offeror shall provide a guaranty agreement (See Form DCMA Form 1620 attached) for the contract price.

e. A list of existing commercial and government business commitments to include contract numbers, names of Contracting Officers, telephone numbers, value of contract, completion date and percent complete. If the list of existing commitments is extensive, provide the required information on at least five projects of similar dollar value and a summary of the existing commitments to include number of contracts, total dollar value of all contracts, and total dollar value of work remaining.

f. Copy of the email confirmation of receipt notification of successful submission of the VETS-4212.

The information submitted for the pre-award survey will not be considered in the technical evaluation unless separately submitted pursuant to the technical evaluation factor submission requirements.

1.6 PARTNERSHIPS, JOINT VENTURES (JV), LIMITED LIABILITY COMPANIES (LLC), LIMITED

PARTNERSHIPS (LP), ETC.

Partnerships, Joint Ventures, Limited Liability Companies, Limited Partnerships and Mentor-Protégé arrangements shall submit the following documentation regarding their business entities:

a. A copy of the Partnership Agreement, JV Agreement(s), LLC Operating Agreement(s), LP Agreement(s), and/or Mentor-Protégé Agreement(s). Contractor shall provide an updated copy whenever any change is made to the agreement.

b. The proposal and each bond or other document submitted by or on behalf of the joint venture shall be executed by each joint venture partner and shall be accompanied by evidence of the authority of the signer. That authority shall be evidenced by a document satisfactory to the Contracting Officer, which would ordinarily be, in the case of a corporate joint venture partner, a certified copy of a resolution of the board of directors, and in the case of an unincorporated joint venture partner, an instrument of similarly binding character duly executed by that entity. If one individual signs for more than one partner, the individual must sign separately for each partner which he or she represents, and must state under each signature the capacity in which he or she is signing (See FAR 4.102).

c. Identify (by name and title) the personnel having the authority to legally bind the Offeror (including authority to execute the contract documents and bonds).

d. Procedures in the event the entity is dissolved.

e. A detailed statement outlining the following in terms of percentages where appropriate:

(1) The relationship of the partners/parties in terms of business ownership, capital contribution, profit distribution or loss sharing.

(2) The management approach in terms of who will conduct, direct, supervise, control, and the controlling partner’s authority to obligate the entity.

N62742-21-R-1334

DOCUMENT 00100

(3) The structure and decision-making responsibilities of the partners/parties in terms of who will control the manner and method of performance of work.

f. Joint Ventures shall submit the following additional documentation regarding their business entities:

(1) Together with its proposal, each corporate joint venture partner shall submit evidence satisfactory to the Contracting Officer that its board of directors has approved its participation in the joint venture. Such evidence shall be in the form of a copy of a resolution of the board of directors, certified by the Secretary of the Corporation.

(2) Together with its proposal, each joint venture partner which is an unincorporated entity shall submit evidence satisfactory to the Contracting Officer that all persons or entities which must approve decisions affecting the joint venture partner have approved the participation of the joint venture partner in the joint venture.

1.7 SUBCONTRACTING PLAN

a. As stated in Document 00202, paragraph 2.1, EVALUATION CRITERIA AND BASIS OF AWARD, this is a lowest priced technically acceptable source selection. Accordingly, small business subcontracting is not included as a technical evaluation factor. However, large business concerns must submit a Small Business Subcontracting Plan that addresses the following:

1. Identify in terms of dollar value and percentage of the total acquisition, the extent of work you will perform as the prime contractor. If submitting an offer as a Joint-Venture, identify the percentage of work each member will be responsible for and indicate the size status of each member, e.g., LB, SB, SDB, WOSB, HUBZone SB, etc.

2. In accordance with FAR 52.219-9, submit a Small Business Subcontracting Plan utilizing the template at the end of this section for this project. To demonstrate commitment in using small business concerns, the Small Business Subcontracting Plan may list all subcontractors by name. If the proposed Small Business Subcontracting goals do not meet the minimum NAVFAC Small Business Subcontracting Targets, include a detailed explanation describing the actions taken to arrive at that determination, along with an explanation for the goals that actually were proposed.

In accordance with FAR 52.219-9, Alternate II, “failure to submit and negotiate a subcontracting plan shall make the offeror ineligible for award of a contract.”

b. NAVFAC's command-wide small business subcontracting targets are shown below. These may be higher or lower than percentages that would represent realistic, challenging small business subcontracting goals for this acquisition. Offerors shall document in their subcontracting plans the basis for all proposed goals. Plans shall be submitted with initial offers.

SB 33%

SDB 5%

HUBZone SB 3%

WOSB 9%

SDVOSB 3%

c. See the Small Business Subcontracting Plan (Template) at the end of Document 00100 for format.

1.8 FAR 52.204-7, SYSTEM FOR AWARD MANAGEMENT (OCT 2018)

(a) Definitions. As used in this provision—

“Electronic Funds Transfer (EFT) indicator” means a four-character suffix to the unique entity identifier. The suffix is assigned at the discretion of the commercial, nonprofit, or Government entity to establish additional System for Award Management records for identifying alternative EFT accounts (see subpart 32.11) for the same entity.

“Registered in the System for Award Management (SAM)” means that–

N62742-21-R-1334

(1) The Offeror has entered all mandatory information, including the unique entity identifier and the EFT indicator, if applicable, the Commercial and Government Entity (CAGE) code, as well as data required by the Federal Funding Accountability and Transparency Act of 2006 (see subpart 4.14) into the SAM;

(2) The offeror has completed the Core, Assertions, and Representations and Certifications, and Points of Contact sections of the registration in the SAM;

(3) The Government has validated all mandatory data fields, to include validation of the Taxpayer Identification Number (TIN) with the Internal Revenue Service (IRS). The offeror will be required to provide consent for TIN validation to the Government as a part of the SAM registration process; and

(4) The Government has marked the record “Active”.

“Unique entity identifier” means a number or other identifier used to identify a specific commercial, nonprofit, or Government entity. See www.sam.gov for the designated entity for establishing unique entity identifiers.

(b) (1) An Offeror is required to be registered in SAM when submitting an offer or quotation, and shall continue to be registered until time of award, during performance, and through final payment of any contract, basic agreement, basic ordering agreement, or blanket purchasing agreement resulting from this solicitation.

(2) The Offeror shall enter, in the block with its name and address on the cover page of its offer, the annotation “Unique Entity Identifier” followed by the unique entity identifier that identifies the Offeror's name and address exactly as stated in the offer. The Offeror also shall enter its EFT indicator, if applicable. The unique entity identifier will be used by the Contracting Officer to verify that the Offeror is registered in the SAM.

(c) If the Offeror does not have a unique entity identifier, it should contact the entity designated at www.sam.gov for establishment of the unique entity identifier directly to obtain one. The Offeror should be prepared to provide the following information:

(1) Company legal business name.

(2) Tradestyle, doing business, or other name by which your entity is commonly recognized.

(3) Company physical street address, city, state, and Zip Code.

(4) Company mailing address, city, state and Zip Code (if separate from physical).

(5) Company telephone number.

(6) Date the company was started.

(7) Number of employees at your location.

(8) Chief executive officer/key manager.

(9) Line of business (industry).

(10) Company headquarters name and address (reporting relationship within your entity).

(d) Processing time should be taken into consideration when registering. Offerors who are not registered in SAM should consider applying for registration immediately upon receipt of this solicitation. See https://www.sam.gov for information on registration.

1.9 FAR 52.204-16, COMMERCIAL AND GOVERNMENT ENTITY CODE REPORTING (AUG 2020)

(a) Definition. As used in this provision –

Commercial and Government Entity (CAGE) code means–

(1) An identifier assigned to entities located in the United States or its outlying areas by the Defense Logistics Agency (DLA) Commercial and Government Entity (CAGE) Branch to identify a commercial or government entity by unique location; or

N62742-21-R-1334

DOCUMENT 00100

(2) An identifier assigned by a member of the North Atlantic Treaty Organization (NATO) or by the NATO Support and Procurement Agency (NSPA) to entities located outside the United States and its outlying areas that the DLA Commercial and Government Entity (CAGE) Branch records and maintains in the CAGE master file. This type of code is known as a NATO CAGE (NCAGE) code.

(b) The Offeror shall provide its CAGE code with its offer with its name and location address or otherwise include it prominently in its proposal. The CAGE code must be for that name and location address. Insert the word “CAGE” before the number. The CAGE code is required prior to award.

(c) CAGE codes may be obtained via–

(1) Registration in the System for Award Management (SAM) at www.sam.gov. If the Offeror is located in the United States or its outlying areas and does not already have a CAGE code assigned, the DLA Commercial and Government Entity (CAGE) Branch will assign a CAGE code as a part of the SAM registration process. SAM registrants located outside the United States and its outlying areas shall obtain a NCAGE code prior to registration in SAM (see paragraph (c)(3) of this provision).

(2) The DLA Contractor and Government Entity (CAGE) Branch. If registration in SAM is not required for the subject procurement, and the Offeror does not otherwise register in SAM, an Offeror located in the United States or its outlying areas may request that a CAGE code be assigned by submitting a request at https://cage.dla.mil.

(3) The appropriate country codification bureau. Entities located outside the United States and its outlying areas may obtain an NCAGE code by contacting the Codification Bureau in the foreign entity's country if that country is a member of NATO or a sponsored nation. NCAGE codes may be obtained from the NSPA at https://eportal.nspa.nato.int/AC135Public/scage/CageList.aspx if the foreign entity’s country is not a member of NATO or a sponsored nation. Points of contact for codification bureaus, as well as additional information on obtaining NCAGE codes, are available at http://www.nato.int/structur/AC/135/main/links/contacts.htm.

(d) Additional guidance for establishing and maintaining CAGE codes is available at https://cage.dla.mil.

(e) When a CAGE code is required for the immediate owner and/or the highest-level owner by Federal Acquisition Regulation (FAR) 52.204-17 or 52.212-3(p), the Offeror shall obtain the respective CAGE code from that entity to supply the CAGE code to the Government.

(f) Do not delay submission of the offer pending receipt of a CAGE code.

(g) If the solicitation includes FAR clause 52.204-2, Security Requirements, a subcontractor requiring access to classified information under a contract shall be identified with a CAGE code on the DD Form 254. The Contractor shall require a subcontractor requiring access to classified information to provide its CAGE code with its name and location address or otherwise include it prominently in the proposal. Each location of subcontractor performance listed on the DD Form 254 is required to reflect a corresponding unique CAGE code for each listed location unless the work is being performed at a Government facility, in which case the agency location code shall be used. The CAGE code must be for that name and location address. Insert the word “CAGE” before the number. The CAGE code is required prior to award.

1.10 FAR 52.211-6, BRAND NAME OR EQUAL (AUG 1999)

(a) If an item in this solicitation is identified as “brand name or equal,” the purchase description reflects the characteristics and level of quality that will satisfy the Government’s needs. The salient physical, functional, or performance characteristics that “equal” products must meet are specified in the solicitation.

(b) To be considered for award, offers of “equal” products, including “equal” products of the brand name manufacturer, must—

(1) Meet the salient physical, functional, or performance characteristic specified in this solicitation;

N62742-21-R-1334

DOCUMENT 00100

(2) Clearly identify the item by—

(i) Brand name, if any; and

(ii) Make or model number;

(3) Include descriptive literature such as illustrations, drawings, or a clear reference to previously furnished descriptive data or information available to the Contracting Officer; and

(4) Clearly describe any modification the offeror plans to make in a product to make it conform to the solicitation requirements. Mark any descriptive material to clearly show the modification.

(c) The Contracting Officer will evaluate “equal” products on the basis of information furnished by the offeror or identified in the offer and reasonably available to the Contracting Officer. The Contracting Officer is not responsible for locating or obtaining any information not identified in the offer.

(d) Unless the offeror clearly indicates in its offer that the product being offered is an “equal” product, the offeror shall provide the brand name product referenced in the solicitation.

1.11 FAR 52.211-14, NOTICE OF PRIORITY RATING FOR NATIONAL DEFENSE, EMERGENCY

PREPAREDNESS, AND ENERGY PROGRAM USE (APR 2008)

Any contract awarded as a result of this solicitation will be _ DX rated order; X DO-C2 rated order certified for national defense, emergency preparedness, and energy program use under the Defense Priorities and Allocations System (DPAS) (15 CFR 700), and the Contractor will be required to follow all of the requirements of this regulation.

1.12 FAR 52.214-34, SUBMISSION OF OFFERS IN THE ENGLISH LANGUAGE (APR 1991)

Offers submitted in response to this solicitation shall be in the English language. Offers received in other than English shall be rejected.

1.13 FAR 52.214-35, SUBMISSION OF OFFERS IN U.S. CURRENCY (APR 1991)

Offers submitted in response to this solicitation shall be in terms of U.S. dollars. Offers received in other than U.S.

dollars shall be rejected.

1.14 FAR 52.215-1, INSTRUCTIONS TO OFFERORS--COMPETITIVE ACQUISITION (JAN 2017)

(a) Definitions. As used in this provision—

“Discussions” are negotiations that occur after establishment of the competitive range that may, at the Contracting Officer’s discretion, result…