This is a Continuation Sheet for a federal construction work order issued by NAVFAC Mid-Atlantic for a Marine Corps facility repair and replacement project.
The document modifies specifications for the FY 26 Marine Corps Barracks – Repair by Replacement project at MCB Camp Lejeune in Jacksonville, North Carolina (eProjects Work Order Number 1894552, dated 22 July 2026). Under Part 3A – Project Program, three specification sections are revised: Windows (B202001) must be changed from operable aluminum windows with insect screens and locks to fixed aluminum windows; Waste Pipe & Fittings (D203001) removes the allowance for PVC piping in above-ground installations; and Chilled Water Distribution Systems (D304006) removes coordination requirements with Site Civil/Mechanical Utilities, removes specifications for insulated type 'K' copper piping, and adds a requirement to follow MCBCL Mechanical Design Guidance for material selections. Under Part 3B – Project Program, Exterior Furnishings (G204003) is revised to add a requirement for exterior drinking fountains at recreation shelters in accordance with Camp Lejeune BEAP requirements specified in Part 6 of the contract documents.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Continuation Sheet eProjects Work Order Number: 1894552
Construction Contract Number: --
Building: --
Project Title: FY 26 Marine Corps Barracks – Repair by Replacement MCB Camp Lejeune – French Creek, Jacksonville, NC
Date: 22 July 2026
PART 3A – PROJECT PROGRAM:
REVISE the following:
B202001 Windows
Replace the statement, “Provide operable aluminum windows with integral insect screens and locks,” with the following: “Provide fixed aluminum windows.”
D203001 Waste Pipe & Fittings
Remove the following: “Unless specified otherwise in base design standards, PVC piping allowed for above ground installations when provided with effective noise reduction.”
D304006 Chilled Water Distribution Systems
Remove First paragraph: “For exterior buried chilled water distribution systems, coordinate with Section G30, Site Civil/Mechanical Utilities.”
Remove First sentence of the third paragraph indicating: “Provide insulated type 'K' copper chilled water supply and return piping to serve the HVAC equipment.”
Add “Follow MCBCL Mechanical Design Guidance for material selections”
PART 3B – PROJECT PROGRAM:
REVISE the following:
G204003 Exterior Furnishings
Add “Provide exterior drinking fountains at recreation shelters, in accordance with the Camp Lejeune