FINAL DESIGN_1667770dwg1of2Sentry.pdf
PDF 7 MB Posted
- Solicitation number
- N4008526R0004
About this file
This is a final design document package for the P-1102 Weapons Magazine & Ordnance Operations Facility (Sentry Building) located at Naval Submarine Base New London in Groton, Connecticut. The document set includes comprehensive architectural, structural, mechanical, plumbing, electrical, and telecommunications drawings dated June 23, 2025, prepared by Jacobs for the Naval Facilities Engineering Systems Command Mid-Atlantic.
The project involves construction of a single-story, approximately 450-square-foot facility designed to support weapons magazine and ordnance operations at the naval base. The structure features concrete foundation and walls, structural steel framing, composite metal deck roof with TPO membrane, architectural CMU exterior with varied finishes, and blast-resistant storefront systems. The design accommodates four operational spaces: a gate/sentry house, toilet facilities, electrical room, and plumbing room. The building is designed for Risk Category II with standard occupancy loads, includes accessible features compliant with ADA requirements, and incorporates fire suppression, security, and environmental control systems. Mechanical systems include ductless split-system air conditioning units, electric unit heaters, and an energy recovery ventilator. Plumbing provisions include water service with backflow prevention, domestic hot water heating, sanitary waste systems, and floor drains. The design reflects naval facility standards including NAVSEA ammunition and explosives safety regulations and UFC building code requirements, with final approval documented from LCDR Elizabeth Olokode, NAVFAC NLON FEAD Director, dated May 27, 2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SITE OF SENTRY BUILDING
VISITOR'S
ENTRANCE
NAVAL SUBMARINE
BASE
NEW LONDON
PROJECT SITE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
4:
:5
PM
\\d c1 vs
\fe dp rj\
FD
ZE
\A
R C
H \B
LD
G
-1
-A -B
IM
_S
EN
TR
Y.
rv t
G-001
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
G
EN
ER
AL
C O
VE
R
SH
EE
T
WS
12894089
PS PS
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
DJD
HPN
M
ID
-A
TL
A N
TI
C
G -0
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
VICINITY / BASE MAP LOCATION MAP
P-1102 WEAPONS MAGAZINE & ORDNANCE OPERATIONS FACILITY
NAVAL SUBMARINE BASE NEW LONDON, GROTON, CONNECTICUT
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND - MID-ATLANTIC
NAVFAC FACILITIES ENGINEERING AND ACQUISITION DIVISION (FEAD)
SENTRY
FINAL DESIGN
6/23/2025
NEK
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
4:
:0
PM
\\d c1 vs
\fe dp rj\
FD
ZE
\A
R C
H \B
LD
G
-1
-A -B
IM
_S
EN
TR
Y.
rv t
G-002
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
G
EN
ER
AL
L
IS
T O
F
SH
EE
TS
WS
12894090
PS PS
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
DJD
HPN
M
ID
-A
TL
A N
TI
C
G -0
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
LIST OF SHEETS
SHEET NO.
NAVFAC DWG. NO. SHEET TITLENO. SHEET
GENERAL
1 G-001 12894089 GENERAL COVER SHEET
2 G-002 12894090 GENERAL LIST OF SHEETS
STRUCTURAL
3 S-001 12894091 GENERAL NOTES, ABBREVIATIONS & LEGEND
4 S-002 12894092 DESIGN CRITERIA & LOADS
5 S-003 12894093 MATERIAL NOTES
6 S-101 12894094 FLOOR & ROOF PLANS
7 S-201 12894095 BUILDING ELEVATIONS
8 S-501 12894096 TYPICAL FOUNDATION & CONCRETE DETAILS
9 S-502 12894097 TYPICAL SLAB-ON-GROUND DETAILS
10 S-503 12894098 TYPICAL CONCRETE WALL DETAILS
11 S-504 12894099 TYPICAL STEEL DETAILS
12 S-510 12894100 SECTIONS & DETAILS
13 S-601 12894101 SCHEDULES
14 S-901 12894102 3D ISOMETRIC VIEWS
ARCHITECTURAL
15 A-001 12894103 ARCHITECTURAL NOTES AND SYMBOLS
16 A-002 12894104 ARCHITECTURAL ACCESSIBILITY STANDARDS & MOUNTING HEIGHTS
17 A-101 12894105 ARCHITECTURAL FLOOR PLANS
18 A-201 12894106 ARCHITECTURAL EXTERIOR ELEVATIONS
19 A-301 12894107 ARCHITECTURAL BUILDING SECTIONS
20 A-302 12894108 ARCHITECTURAL WALL SECTIONS
21 A-501 12894109 ARCHITECTURAL EXTERIOR DETAILS
22 A-502 12894110 ARCHITECTURAL EXTERIOR DETAILS
23 A-503 12894111 OPENING DETAILS
24 A-601 12894112 ARCHITECTURAL SCHEDULES
25 A-602 12894113 ARCHITECTURAL PARTITION TYPES
INTERIORS
26 I-101 12894114 FF&E PLAN & SCHEDULE
27 I-102 12894115 INTERIOR FINISH PLAN & ROOM FINISH SCHEDULE
28 I-103 12894116 SIGNAGE PLAN & SCHEDULE
29 I-401 12894117 INTERIOR ENLARGED PLANS & ELEVATIONS
30 I-501 12894118 INTERIOR DETAILS
PLUMBING
31 P-001 12894119 PLUMBING LEGEND AND GENERAL NOTES
32 P-101 12894120 PLUMBING FLOOR PLANS
33 P-501 12894121 PLUMBING DETAILS
34 P-601 12894122 PLUMBING SCHEDULES
35 P-901 12894123 PLUMBING RISER DIAGRAMS
MECHANICAL
36 M-001 12894124 MECHANICAL LEGEND, ABBREVIATIONS AND NOTES
37 M-101 12894125 MECHANICAL FLOOR PLAN - DUCTWORK
38 MP101 12894126 MECHANICAL FLOOR PLAN - PIPING
39 M-501 12894127 MECHANICAL DETAILS
40 M-601 12894128 MECHANICAL SCHEDULES
41 M-800 12894129 CONTROLS LEGEND
42 M-801 12894130 CONTROLS DIAGRAMS & SEQUENCES
ELECTRICAL
43 E-001 12894131 ELECTRICAL GENERAL NOTES
44 E-002 12894132 ELECTRICAL ABBREVIATIONS
45 E-003 12894133 ELECTRICAL SYMBOLS
46 E-004 12894134 ELECTRICAL SYMBOLS
47 EG101 12894135 ELECTRICAL GROUNDING AND LIGHTNING PROTECTION PLAN
48 EL101 12894136 ELECTRICAL LIGHTING PLAN
49 EP101 12894137 ELECTRICAL POWER AND EQUIPMENT POWER PLAN
50 E-501 12894138 ELECTRICAL DETAILS
51 E-502 12894139 ELECTRICAL DETAILS
52 E-601 12894140 ELECTRICAL POWER SINGLE LINE DIAGRAM
53 E-701 12894141 LIGHTING FIXTURE AND CONTROLS SCHEDULES
54 E-702 12894142 ELECTRICAL PANEL SCHEDULES
55 E-703 12894143 ELECTRICAL FEEDER SCHEDULE
TELECOMMUNICATIONS
56 T-001 12894144 TELECOMMUNICATIONS SYMBOLS, LEGEND, ABBREVIATIONS, AND NOTES
57 T-101 12894145 TELECOMMUNICATIONS FLOOR PLAN
58 T-401 12894146 TELECOMMUNICATIONS ENLARGED PLANS
59 T-501 12894147 TELECOMMUNICATIONS DETAILS
60 T-502 12894148 TELECOMMUNICATIONS DETAILS
61 T-503 12894149 TELECOMMUNICATIONS DETAILS
SECURITY
62 TY001 12894325 SECURITY SYMBOLS, LEGEND, ABBREVIATIONS, AND NOTES
63 TY101 12894150 SECURITY FLOOR PLAN
64 TY501 12894151 SECURITY DETAILS
65 TY502 12894152 SECURITY DETAILS
NEK
SY
M
DE
SC
RI
PT
IO
N
DA
TE
THE FOLLOWING CODES AND STANDARDS, AS MODIFIED BY THE
REFERENCED UFC PUBLICATIONS, APPLY TO THE DESIGN AND
CONSTRUCTION OF THIS PROJECT:
1. UFC 1-200-01, DOD BUILDING CODE, 1 SEPTEMBER 2022
2. UFC 3-301-01, STRUCTURAL ENGINEERING, CHANGE, 04 FEBRUARY
3. ASCE 7-16, MINIMUM DESIGN LOADS AND ASSOCIATED CRITERIA FOR
BUILDINGS AND OTHER STRUCTURES
4. IBC 2021, INTERNATIONAL BUILDING CODE
5. ACI 318-19, BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE
6. AISC 303-16, CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS
AND BRIDGES
7. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
8. RCSC 2020, SPECIFICATION FOR STRUCTURAL JOINTS USING HIGH-
STRENGTH BOLTS
9. AWS D1.1-2020, STRUCTURAL WELDING CODE - STEEL
10. SDI C-2017, STANDARD FOR COMPOSITE STEEL FLOOR DECK - SLABS
11. NAVSEA OP5, AMMUNITION AND EXPLOSIVES ASHORE SAFETY
REGULATIONS FOR HANDLING, STORAGE, PRODUCTION,
RENOVATION, & SHIPPING
CODES AND STANDARDS
GENERAL NOTES
1. ELEVATIONS NOTED ON THE STRUCTURAL DRAWINGS ARE RELATIVE
TO TOP OF THE FIRST/GROUND FLOOR SLAB. SEE CIVIL DRAWINGS
FOR THE ELEVATION OF THE FIRST/GROUND FLOOR RELATIVE TO
MEAN SEA LEVEL.
2. DETAILS LABELED "TYPICAL DETAILS" OR DETAILS ON SHEETS
WHERE THE TITLE INCLUDES "TYPICAL DETAILS" APPLY TO
SITUATIONS THAT ARE THE SAME OR SIMILAR TO THOSE
SPECIFICALLY DETAILED. SUCH DETAILS AND DIMENSIONS APPLY
WHETHER OR NOT DETAILS ARE REFERENCED AT EACH LOCATION.
3. DETAILS NOT LABELED AS "TYPICAL" APPLY AT THE SPECIFIC
LOCATIONS INDICATED AND OTHER SIMILAR CONDITIONS.
4. SLOPING DECK PLANES ARE USUALLY DEFINED BY A WORK POINT
ELEVATION AND A SLOPE OR A HIGH AND LOW POINT ELEVATION.
STEEL MEMBERS SUPPORTING A SLOPING DECK PLANE HAVE THEIR
TOP OF STEEL COINCIDENT WITH THE BOTTOM OF DECK, UON.
5. DO NOT REPRODUCE THE STRUCTURAL DRAWINGS FOR USE AS
SHOP DRAWINGS. SHOP DRAWINGS PREPARED IN SUCH A MANNER
WILL BE REJECTED AND RETURNED WITHOUT REVIEW.
CONSTRUCTION REQUIREMENTS
1. REVIEW AND VERIFY EXISTING CONDITIONS AND DIMENSIONS PRIOR
TO SUBMISSION OF SHOP DRAWINGS AND BEGINNING
CONSTRUCTION.
2. CONFIRM ACTUAL EQUIPMENT DIMENSIONS USING APPROVED
MANUFACTURER/ VENDOR DRAWINGS PRIOR TO SUBMISSION OF
SHOP DRAWINGS.
3. DETERMINE AND COORDINATE THE SIZE & LOCATION OF CHASES,
INSERTS, OPENINGS, SLEEVES, FINISHES, DEPRESSIONS,
HOUSEKEEPING PADS, AND EQUIPMENT SUPPORTS (INCLUDING
FOUNDATIONS) BEFORE SUBMITTING SHOP DRAWINGS.
4. SUBMIT DIMENSIONED SHOP DRAWINGS SHOWING THE LOCATION OF
SLEEVES AND OPENINGS THROUGH MASONRY WALLS, STRUCTURAL
STEEL MEMBERS AND CONCRETE ELEMENTS. OPENINGS THROUGH
A STRUCTURAL MEMBER MUST BE SHOWN ON THE SAME DRAWING.
DRAWINGS ORGANIZED BY DISCIPLINE OR SUB-CONTRACTOR ARE
NOT ACCEPTABLE. OPENINGS NOT SHOWN ON THE SHOP
DRAWINGS REQUIRE THE WRITTEN APPROVAL OF THE COR BEFORE
INSTALLATION.
5. DO NOT FIELD CUT OR DRILL OPENINGS IN STRUCTURAL MEMBERS
UNLESS INDICATED ON THE ACCEPTED SHOP DRAWINGS OR
APPROVED BY THE COR.
6. REFER TO THE ARCHITECTURAL DRAWINGS FOR DETAILED
INFORMATION REGARDING FINISHES, WATERPROOFING,
NON-BEARING MASONRY PARTITIONS, ETC.
7. DO NOT SCALE DRAWINGS FOR THE PURPOSE OF ESTABLISHING
DIMENSIONS.
8. D0 NOT CHANGE THE SIZE, DIMENSION OR POSITION OF STRUCTURAL
ELEMENTS WITHOUT THE WRITTEN APPROVAL OF THE COR.
9. DO NOT STORE OR STACK CONSTRUCTION MATERIALS ON FLOORS
OR ROOFS IN EXCESS OF 80 PERCENT OF INDICATED LIVE LOAD.
10. THE STRUCTURE IS DESIGNED TO BE STABLE IN THE COMPLETED
CONDITION. PROVIDE BRACING AND SHORING TO MAINTAIN THE
STABILITY OF THE STRUCTURE AND TO AVOID OVER-LOADING THE
STRUCTURE DURING CONSTRUCTION. RETAIN A REGISTERED
PROFESSIONAL OR STRUCTURAL ENGINEER TO DESIGN THE
TEMPORARY SUPPORT SYSTEM AND ADVISE ON TEMPORARY
LOADING CONDITIONS.
DELEGATED DESIGN
1. FOUNDATION SUBGRADE IMPROVEMENT SYSTEM
2. EXCAVATION DEWATERING AND EARTH RETENTION SYSTEM
3. SUPPLEMENTARY FRAMING TO SUPPORT PIPES, DUCTS,
MECHANICAL EQUIPMENT, ELECTRICAL EQUIPMENT, ETC.
4. TEMPORARY SHORING AND BRACING
5. STRUCTURAL STEEL CONNECTIONS
6. BLAST RESISTANT STOREFRONT SYSTEM
GRAPHIC LEGEND
CONCRETE
STEEL
ROOF MECHANICAL EQUIPMENT
EXTENT OF SLAB-ON-GROUND
EXTENT OF FRAMED SLAB
FRAMED SLAB SPAN DIRECTION
[-X' - X"] INDICATES THE DIFFERENCE IN ELEVATION
BETWEEN THE TOP OF THE FOUNDATION,
PEDESTAL, SLAB, ROOF DECK OR BEAM AND
THE TOP OF THE FIRST/GROUND FLOOR SLAB
# KEYNOTE
STEEL BEAM & BRACING LEGEND
WALL FOOTING LEGEND
STEP IN FOOTING
[-X
X"
[-X
X"
T/ FTG ELEV
T/FTG ELEV
NOTE: IF THE FTG ELEV IS OMITTED, REFER TO
THE GENERAL SHEET NOTES
V35 V35W12x22 C=1"
FACTORED VERTICAL SHEAR
REACTION (KIPS), REFER TO
SCHEDULE IF OMITTED
BEAM CAMBER, NONE IF OMITTED
BEAM / GIRDER SIZE
ABV ABOVE
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADJ ADJACENT
AE AIR ENTRAINED
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT ALTERNATE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
AR ANCHOR ROD
ARCH ARCHITECT or ARCHITECTURAL
ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS
AWS AMERICAN WELDING SOCIETY
B/ or BOT BOTTOM
BF BOTH FACES
BLDG BUILDING
BM BEAM
BOS BOTTOM OF STEEL
BP BEARING PLATE
BPL BASE PLATE
BRDG BRIDGING
BRG BEARING
BS BOTH SIDES
BTWN BETWEEN
℄ CENTERLINE
C/C CENTER TO CENTER
CANT CANTILEVER
CF CUBIC FEET
CFMF COLD-FORMED METAL FRAMING
CFRP CARBON FIBER REINFORCED POLYMER
CIP CAST-IN-PLACE
CJ CONTRACTION / CONTROL JOINT
CJP COMPLETE JOINT PENETRATION
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
COORD COORDINATE
COR CONTRACTING OFFICER'S REPRESENTATIVE
CY CUBIC YARD
D DEPTH
db REINF BAR DIAMETER
DBA DEFORMED BAR ANCHOR
DEMO DEMOLITION
DIA OR ⌀ DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DL DEAD LOAD
DN DOWN
DWG(S) DRAWING(S)
(E) EXISTING
EA EACH
EE EACH END
EF EACH FACE
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRIC or ELECTRICAL
ELEV ELEVATOR
EMBED EMBEDMENT
EOD EDGE OF DECK
EOR ENGINEER OF RECORD
EOS EDGE OF SLAB
EQ EQUAL
EQUIP EQUIPMENT
ES EACH SIDE
EW EACH WAY
EXIST EXISTING
EXP EXPANSION
EXT EXTERIOR
FA FALL ARREST ANCHOR
FD FLOOR DRAIN
FDN FOUNDATION
FIN FINISH or FINISHED
FLG FLANGE
FLR FLOOR
FOW FACE OF WALL
FP FIRE PROTECTION
FRP FIBER REINFORCED POLYMER
FT FOOT or FEET
FTG FOOTING
GA GAGE or GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
ABBREVIATIONS
H HIGH OR HORIZONTAL
HK HOOK
HORIZ HORIZONTAL
HP HIGH POINT
HS HIGH STRENGTH
HT HEIGHT
ID INSIDE DIAMETER
IF INSIDE FACE
IN INCH
INCL INCLUDED
INFO INFORMATION
INT INTERIOR
IP INFLECTION POINT
JT JOINT
JST JOIST
K KIPS (1000 POUNDS)
KB KNEE BRACE
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
LBS POUND(S)
Ld REINF BAR DEVELOPMENT LENGTH
LE LEFT END
LL LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LP LOW POINT
LTWT LIGHT WEIGHT
MAX MAXIMUM
MC MOMENT CONNECTION
MECH MECHANICAL
MEP MECHANICAL, ELECTRICAL AND PLUMBING
MID MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
MWFRS MAIN WIND FORCE RESISTING SYSTEM
NIC NOT IN CONTRACT
NLWT NORMAL WEIGHT
NOM NOMINAL
No. or # NUMBER
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OF OUTSIDE FACE
OPNG OPENING
OPP OPPOSITE OR OPPOSITE HAND
PCF POUNDS PER CUBIC FOOT
PEN PENETRATION
PJP PARTIAL JOINT PENETRATION
PL PLATE
PLUMB PLUMBING
PROJ PROJECTION
PS PRESTRESSED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
R RISER OR RADIUS
RE RIGHT END
REBAR REINFORCING STEEL BARS
REINF REINFORCEMENT or REINFORCING
RTU ROOF TOP UNIT
SC SLIP CRITICAL
SCHED SCHEDULE
SDI STEEL DECK INSTITUTE
SDL SUPERIMPOSED DEAD LOAD
SHT SHEET
SIM SIMILAR
SJI STEEL JOIST INSTITUTE
SFRS SEISMIC FORCE RESISTING SYSTEM
SOG SLAB-ON-GROUND
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
T TREAD
T/ TOP
TEMP TEMPORARY
THK THICK or THICKNESS
TMS THE MASONRY SOCIETY
TOS TOP OF STEEL
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
V VERTICAL
VERT VERTICAL
VIF VERIFY IN FIELD
W WIDTH
W/ WITH
W/CM WATER-CEMENTITIOUS MATERIAL RATIO
W/O WITHOUT
WD WOOD
WP WORK POINT
WT WEIGHT
WWR WELDED WIRE REINFORCING
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
R
S
T
U
W
V
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:4
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-001
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
G
EN
ER
AL
N O
TE
S, A
BB
RE
VI
AT
IO
NS
L
EG
EN
D
LP
12894091
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -0
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
SY
M
DE
SC
RI
PT
IO
N
DA
TE
3. BUILDING RISK CATEGORY II
4. SNOW
a. SNOW IMPORTANCE FACTOR, Is 1.0
b. GROUND SNOW LOAD, Pg 30 PSF
c. TERRAIN ROUGHNESS C
d. ROOF EXPOSURE FACTOR, Ce 1.0 PARTIALLY
EXPOSED
e. THERMAL FACTOR, Ct 1.0
f. ROOF SLOPE FACTOR, Cs 1.0
g. FLAT-ROOF SNOW LOAD, Pf 21 PSF
h. MINIMUM UNIFORM SNOW LOAD, Pm 20 PSF
i. MAXIMUM DRIFT SURCHARGE 19 PSF
j. TOTAL UNIFORM SNOW W/ DRIFT 39 PSF
5. RAIN
a. INTENSITY, i 2.75 IN/HOUR
6. WIND
a. ULTIMATE DESIGN WIND SPEED, V: 128 MPH
b. ALLOWABLE STRESS WIND SPEED, Vasd: 99 MPH
c. WIND EXPOSURE: C
d. INTERNAL PRESSURE COEF, GCpi ±0.18
e. MAIN WIND-FORCE RESISTING SYSTEM
• 0 FT - ROOF 31 PSF
• PARAPET 70 PSF
f. COMPONENTS & CLADDING REFER TO TABLE 1
7. EARTHQUAKE
a. SEISMIC IMPORTANCE FACTOR 1.0
b. SEISMIC SITE CLASSIFICATION D
c. MAPPED SPECTRAL ACCELERATION
• SHORT PERIOD, SS 0.190g
• 1-SECOND PERIOD, S1 0.052g
d. DESIGN SPECTRAL ACCELERATION
• SHORT PERIOD, SDS 0.203g
• 1-SECOND PERIOD, SD1 0.083g
e. SEISMIC DESIGN CATEGORY B
f. SEISMIC FORCE-RESISTING SYSTEM
ORDINARY REINFORCED CONCRETE SHEAR WALLS
g. RESPONSE MODIFICATION COEF, R 4
h. SYSTEM OVERSTRENGTH COEF, Ω0 2.5
i. DEFLECTION AMPLIFICATION COEF, Cd 4
j. ANALYSIS PROCEDURE EQUIVALENT
LATERAL FORCE
k. SEISMIC RESPONSE COEF, CS 0.051
l. SEISMIC WEIGHT, W 161 KIPS
m. DESIGN BASE SHEAR 8.2 KIPS
8. FOUNDATIONS
a. MINIMUM SOIL BEARING CAPACITY 4,000 PSF
b. FROST DEPTH 38 IN
DESIGN CRITERIA & LOADS
ROOF MEMBRANE & INSULATION
1. TOTAL SUPERIMPOSED DEAD LOAD
CEILING
CONCRETE ALLOWANCE FOR
DECK DEFLECTION
CONCRETE HOUSEKEEPING PAD
(4" MINIMUM)
RO
OF
A
BO
VE
E
LE
CT
RI
C
RO
OM
EL
EC
TR
IC
R
OO
M
FL
OO
R
SE
NT
RY
T
OI
LE
T
RO
OM
F
LO
OR
RO
OF
A
BO
VE
S
EN
TR
Y
TO
ILE
T
RO
OM
S
2. LIVE LOAD
5 -----
5 -----
10MEP
SUPERIMPOSED DEAD & LIVE LOADS
(UNFACTORED - PSF)
125 75
020 20
---------- -----50
20 20
1. FOR MEMBERS, THE EFFECTIVE WIND AREA IS THE SPAN LENGTH MULTIPLIED BY THE WIDTH, WHERE THE WIDTH EQUALS THE GREATER OF THE WIDTH TRIBUTARY TO THE MEMBER OR 1/3 THE SPAN LENGTH.
2. FOR FASTENERS, THE EFFECTIVE WIND AREA MUST NOT BE TAKEN GREATER THAN THE AREA THAT IS
TRIBUTARY TO AN INDIVIDUAL FASTENER.
3. PRESSURES INDICATED ARE THE TOTAL APPLIED WIND PRESSURE AND INCLUDE BOTH THE INTERNAL
AND EXTERNAL PRESSURES.
4. WIND PRESSURES ARE FACTORED LOADS.
5. POSITIVE VALUES INDICATE PRESSURE ACTING TOWARDS THE SURFACE AND NEGATIVE VALUES
INDICATE PRESSURE ACTING AWAY FROM THE SURFACE.
TABLE 1 - COMPONENTS & CLADDING WIND PRESSURE (PSF)
ROOF
WALLS
4w
5w
4p
PARAPET
5p
-57 / +16
ZONE
≤10 20 50 100 200 ≥500
EFFECTIVE WIND AREA (SF)
-36 / +33
-53 / +16 -48 / +16 -45 / +16 -41 / +16 -36 / +16
-34 / +31 -32 / +30 -31 / +28 -29 / +27 -28 / +25
-75 / +16 -70 / +16 -64 / +16 -59 / +16 -54 / +16 -48 / +16
-102 / +16 -93 / +16 -80 / +16 -70 / +16 -61 / +16 -48 / +16
-44 / +33 -41 / +31 -37 / +30 -34 / +28 -31 / +27 -28 / +25
-75 / +33 -70 / +31 -64 / +30 -59 / +28 -54 / +27 -48 / +25
-102 / +33 -93 / +31 -80 / +30 -70 / +28 -61 / +27 -48 / +25
ZONE 4w
ZONE 4p
ZONE 5w
ZONE 5p
FINISHED GRADE
ROOF
T/ PARAPET
7' - 6"
7' - 6"
7' - 6"
7' - 6"
2' - 6" 2' - 6"
ZONE 1
ZONE 2
ZONE 4p ZONE 5p
ZONE 5w
ZONE 5p
ZONE 3
3' - 0"
3' - 0"
3' - 0"
3' - 0"
ZONE 4w
ZONE 4p
ZONE 5w
ZONE 5p
A
1 2
B
41 PSF
P
SF
P
SF
41 PSF
TYP
4' - 5"
21 PSF
FIGURE 1 - DESIGN ROOF SNOW LOAD W/ DRIFT
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:4
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-002
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
DE
SI
GN
C
RI
TE
RI
A
LO
AD
S
LP
12894092
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -0
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
SY
M
DE
SC
RI
PT
IO
N
DA
TE
FOUNDATIONS AND EARTHWORK
CAST-IN-PLACE CONCRETE
POST-INSTALLED ANCHORS
STEEL DECKING
1. COMPOSITE DECK:
a. CONFORM TO THE REQUIREMENTS OF ASTM A653, Fy = 50 KSI
MIN, GALVANIZED G90.
b. STEEL ROOF DECK MUST BE 1 1/2" HIGH, 20 GAUGE. DECK IS
DESIGNED BASED ON UNSHORED CONSTRUCTION FOR A TWO
SPAN CONDITION. INCREASE DECK THICKNESS OR PROVIDE
TEMPORARY SHORING IF LESS THAN TWO SPAN CONDITION OR
CONSTRUCTION LIVE LOAD EXCEEDS 20 PSF.
c. THE STEEL ROOF DECK MUST HAVE THE FOLLOWING MINIMUM
PROPERTIES PER FOOT WIDTH:
Ip = 0.182 IN4 Sp = 0.218 IN3 Sn = 0.226 IN3
2. DECK ENDS MUST BEAR AT LEAST 1 1/2" ON STRUCTURAL SUPPORTS.
END JOINTS MUST BE BUTTED.
3. CONTINUOUS SHEET METAL CLOSURES ARE REQUIRED AT SLAB
OPENINGS AND EDGES.
4. COMPOSITE DECK FASTENING:
a. FASTEN DECK TO EACH SUPPORT WITH 5/8" DIAMETER PUDDLE
WELDS. WELD EDGE RIBS OF PANELS AND PROVIDE ADDITIONAL
WELDS AT MAXIMUM 12" ON CENTER.
b. FASTEN SIDE LAPS WITH #10 SELF DRILLING SCREWS AT THE
LESSER OF 1/2 OF THE SPAN OR 36" ON CENTER, UON.
c. FASTEN PERIMETER EDGES TO SIDE SUPPORTS WITH #10 SELF
DRILLING SCREWS AT THE LESSER OF 1/2 OF THE SPAN OR 24"
ON CENTER, UON.
d. SECURE POUR STOPS, BEAM FILLERS & DECK CLOSURES IN
ACCORDANCE WITH SDI STANDARD PRACTICE REQUIREMENTS.
5. LOADS HUNG FROM CEILING DECKING MUST NOT EXCEED 50 POUNDS.
DUCTS & PIPES LESS THAN 12 INCHES DIAMETER MAY BE HUNG
DIRECTLY FROM ANCHORS CAST OR POST-INSTALLED IN THE
CONCRETE SLAB OF COMPOSITE DECKS. PIPES, DUCTS AND
EQUIPMENT BENEATH ROOF DECKS AND PIPES AND DUCTS LARGER
THAN 12" BENEATH COMPOSITE CONCRETE AND STEEL DECK SLABS
MUST BE SUPPORTED BY THE STRUCTURAL STEEL FRAME OR
SUPPLEMENTARY MEMBERS THAT ARE DIRECTLY SUPPORTED BY THE
STRUCTURAL STEEL FRAMING. DESIGN AND PROVIDE
SUPPLEMENTARY MEMBERS AT NO ADDITIONAL COST.
1. FOUNDATION DESIGN IS IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE GEOTECHNICAL ENGINEERING REPORT
PREPARED BY JACOBS, DATED 07 FEBRUARY 2025.
2. PLACE FOUNDATIONS ON REINFORCED AND COMPACTED
ENGINEERED FILL OVER CEMENTITIOUS RIGID INCLUSIONS (GROUND
IMPROVEMENT SYSTEM), REFER TO CIVIL PLANS SHEET B-101,
GROUND IMPROVEMENT PLANS FOR ADDITIONAL REQUIREMENTS.
GROUND IMPROVEMENT SYSTEM MUST CREATE A FOUNDATION
SUBGRADE WITH THE MINIMUM BEARING CAPACITY AS NOTED ON
S-002 AND A MAXIMUM ALLOWABLE SETTLEMENT OF 3/4 INCH.
3. PROVIDE MEASURES TO PREVENT WATER, FROST OR ICE FROM
PENETRATING FOOTING OR SLAB SUBGRADE BEFORE PLACING
CONCRETE. FOOTINGS, MUD SLABS, OR BUILDING SLABS MUST NOT
BE PLACED INTO OR AGAINST SUBGRADE CONTAINING FREE WATER,
FROST, OR ICE.
4. CONCRETE FOUNDATIONS OR A 3" THICK CONCRETE MUD MAT (LEAN
CONCRETE) MUST BE PLACED THE SAME DAY THE SUBGRADE IS
INSPECTED. IF THE GROUND SURFACE IS DISTURBED BEFORE
CONCRETE IS PLACED, THE SUBGRADE MUST BE RE-INSPECTED BY
THE CONTRACTOR'S GEOTECHNICAL ENGINEER AT NO ADDITIONAL
COST.
5. DESIGN, PROVIDE AND MAINTAIN DEWATERING SYSTEMS, EARTH
RETENTION SYSTEMS, BRACING. PROTECT EXISTING STRUCTURES
AND UTILITIES DURING CONSTRUCTION.
6. WHEN FILLING AGAINST OPPOSITE SIDES OF A WALL OR STRUCTURE,
BACKFILL IN LIFTS THAT MAINTAIN LEVEL ELEVATIONS WITHIN 12" ON
BOTH SIDES TO BALANCE THE LATERAL PRESSURE.
7. EARTHWORK, INCLUDING FOUNDATION SUBGRADE, FILL AND
BACKFILL MUST BE INSPECTED AND APPROVED BY THE
CONTRACTOR'S GEOTECHNICAL ENGINEER.
8. WHERE EXCAVATION WOULD BE BELOW A LINE EXTENDING UPWARD
AT A 1.0 H TO 1.0 V SLOPE FROM THE BOTTOM OF A FOUNDATION OR
UTILITY, PROVIDE SHEETING, SHORING, AND BRACING. DO NOT
UNDERMINE EXISTING CONSTRUCTION.
1. PROVIDE CAST-IN-PLACE CONCRETE FOR EACH CLASS OF CONCRETE
SHOWN IN TABLE 2 - CONCRETE MATERIAL SCHEDULE.
2. CONCRETE REINFORCING:
a. TYPICAL DEFORMED BARS - ASTM A615, GRADE 60
b. WELDED DEFORMED BAR ANCHORS - ASTM A706, GRADE 70
c. PLAIN WELDED WIRE - ASTM A1064, GRADE 65, SUPPLIED IN FLAT
SHEETS
3. CONCRETE COVER OVER STEEL REINFORCING, UON:
a. REINFORCING IN CONCRETE CAST AGAINST & PERMANENTLY IN
CONTACT WITH GROUND - 3"
b. REINFORCING IN CONCRETE EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND AFTER CONCRETE PLACEMENT,
INCLUDING ELEMENTS COVERED BY WATERPROOFING OR
DAMPPROOFING
• PRIMARY REINFORCING - 2"
• STIRRUPS AND TIES - 1 1/2"
c. REINFORCING IN CONCRETE SLABS AND WALLS NOT EXPOSED
TO WEATHER OR IN CONTACT WITH GROUND - 3/4"
d. REINFORCING IN CONCRETE BEAMS, GIRDERS, COLUMNS AND
PEDESTALS NOT EXPOSED TO WEATHER OR IN CONTACT WITH
GROUND, COVER TO - 1 1/2"
4. REFER TO TABLE 3 - CONCRETE REINFORCEMENT TENSION
DEVELOPMENT LENGTHS FOR Ld.
5. SPLICE REINFORCING BARS PER ACI 318 WITH CLASS B TENSION LAP
SPLICES (1.3 TIMES THE DEVELOPMENT LENGTH)
6. LAP SPLICE WWR SHEETS AT LEAST 8" AND TIE SECURELY.
7. DOWELS MUST MATCH SIZE AND SPACING AND BE CLASS B TENSION
LAP SPLICED WITH THE MAIN REINFORCEMENT, UON.
8. FIELD BENDING OF REINFORCEMENT IS NOT PERMITTED UNLESS
INDICATED ON THE DRAWINGS OR APPROVED IN WRITING BY THE
COR. DO NOT HEAT REBAR WITH A TORCH IN THE FIELD.
9. EXCEPT FOR WELDED DEFORMED BAR ANCHORS, DO NOT WELD
REINFORCING.
10. WIRE BRUSH, CLEAN, AND COAT CONSTRUCTION JOINTS WITH A
BONDING AGENT OR MOISTEN WITH A CEMENT SLURRY SCRUBBED
INTO THE JOINT IMMEDIATELY PRIOR TO PLACING FRESH CONCRETE.
11. CHAMFER EXPOSED CORNERS 3/4", UON.
STRUCTURAL & MISCELLANEOUS STEEL
1. STRUCTURAL STEEL MUST CONFORM TO THE FOLLOWING, UON:
a. W & WT SHAPES ASTM A992
b. ANGLES & CHANNELS ASTM 572, GR 50
c. PLATES & BARS ASTM 572. GR 50
d. HSS ASTM A500, GRADE C
e. ANCHOR RODS ASTM F1554, GRADE 36
f. HIGH STRENGTH BOLTS ASTM F3125, GRADE A325
g. TENSION-CONTROL HS BOLTS ASTM F3125, GRADE F1852, TYPE 1
h. DIRECT TENSION INDICATORS ASTM F959, TYPE 325-1
i. COMMON GRADE BOLTS ASTM A307, GRADE A
j. WELDING ELECTRODES E70xx
2. GROUT UNDER STEEL BEARING PLATES MUST HAVE A MINIMUM 28
DAY COMPRESSIVE STRENGTH OF 7,000 PSI.
3. FILLET WELDS MUST HAVE A MINIMUM SIZE OF 1/4", UON. INCREASE
THE EFFECTIVE THROAT OF THE WELD TO MAINTAIN THE WELD SIZE
WHEN PARTS JOINED BY FILLET WELDS ARE SEPARATED. THE ROOT
OPENING MUST NOT EXCEED 3/16".
4. BOLTED CONNECTIONS MUST HAVE A MINIMUM OF (2) 3/4" DIAMETER
HIGH STRENGTH BOLTS.
5. MEMBERS EXPOSED TO WEATHER MUST BE HOT DIPPED
GALVANIZED.
6. PROVIDE ZINC COATED (GALVANIZED) BOLTS, NUTS, AND WASHERS
TO CONNECT GALVANIZED STEEL MEMBERS.
7. HIGH STRENGTH BOLTED CONNECTIONS MUST BE PRETENSIONED.
CONNECTIONS THAT USE OVERSIZE HOLES OR SLOTTED HOLES IN
THE DIRECTION OF THE LOAD MUST BE SLIP CRITICAL.
8. PROVIDE STEEL TO STEEL CONNECTIONS IN ACCORDANCE WITH AISC
360-16. CONNECTIONS NOT SPECIFICALLY DETAILED ON THE
DRAWINGS MUST BE DESIGNED BASED ON A BEAM END REACTION
OBTAINED FROM THE MAXIMUM UNIFORM LOAD TABLES IN PART 3
(DESIGN OF FLEXURAL MEMBERS). THE END REACTION IS EQUAL TO
1/2 THE TOTAL ALLOWABLE LOAD FOR THE GIVEN BEAM, SPAN AND
GRADE OF STEEL SPECIFIED. DETAILED CONNECTIONS ON THE
DRAWINGS SUPERCEDE THIS NOTE.
9. DO NOT FIELD CUT STRUCTURAL STEEL MEMBERS WITHOUT THE
WRITTEN APPROVAL OF THE COR.
10. DO NOT SPLICE STEEL MEMBERS EXCEPT WHERE SPECIFICALLY
DETAILED ON THE DRAWINGS.
11. PROVIDE TEMPORARY SHORING AND BRACING UNTIL THE
STRUCTURE IS ALIGNED AND PERMANENT CONNECTIONS HAVE BEEN
COMPLETED.
1. ANCHORS AND INSERTS EXPOSED TO EARTH OR WEATHER MUST BE
STAINLESS STEEL, UON. AT OTHER LOCATIONS PROVIDE
GALVANIZED ANCHORS IN ACCORDANCE WITH ASTM A153.
EMBEDDED DEFORMED REINFORCING BARS MUST BE UNCOATED
STEEL.
2. PROVIDE TYPE & SIZE AS INDICATED & EMBED INTO THE EXISTING
CONCRETE AS SHOWN IN TABLE 4 - POST-INSTALLED ANCHOR
SCHEDULE. VERIFY MINIMUM EFFECTIVE EMBEDDMENT DEPTH WITH
THE ANCHOR MANUFACTURER.
3. EXPANSION ANCHORS MUST BE WEDGE TYPE, TORQUE
CONTROLLED.
4. ADHESIVE ANCHORS MUST CONSIST OF AN INSERT AND CARTRIDGE
TYPE, TWO COMPONENT, EPOXY OR HYBRID ADHESIVE DISPENSED
AND MIXED THROUGH A STATIC MIXING NOZZLE PROVIDED BY THE
ADHESIVE MANUFACTURER.
5. ANCHORING TO CONCRETE:
a. MECHANICAL ANCHORS USED IN CONCRETE MUST HAVE BEEN
TESTED AND QUALIFIED FOR PERFORMANCE IN CRACKED AND
UNCRACKED CONCRETE IN ACCORDANCE WITH ACI 355.2.
b. ADHESIVE ANCHORS MUST HAVE BEEN TESTED AND QUALIFIED
FOR PERFORMANCE IN CRACKED AND UNCRACKED CONCRETE,
INCLUDING HORIZONTAL AND OVERHEAD INSTALLATIONS, AND
LONG TERM CREEP IN ACCORDANCE WITH ACI 355.4.
6. IDENTIFY POSITION OF REINFORCING STEEL AND OTHER EMBEDDED
ITEMS PRIOR TO DRILLING HOLES FOR ANCHORS. EXERCISE CARE IN
DRILLING TO AVOID DAMAGING EXISTING REINFORCING OR
EMBEDDED ITEMS. NOTIFY THE COR IF REINFORCING STEEL OR
OTHER EMBEDDED ITEMS ARE ENCOUNTERED DURING DRILLING.
7. PROVIDE ANCHORS IN DRY HAMMER DRILLED HOLES IN ACCORDANCE
WITH MANUFACTURER’S PRINTED INSTRUCTIONS.
1. MAXIMUM SLUMP OF CONCRETE AT POINT OF PLACEMENT - WITHOUT / WITH HIGH-RANGE WATER-REDUCING ADMIXTURE
2. REFER TO CIVIL FOR CONCRETE SITE WALLS
TABLE 2 - CONCRETE MATERIAL SCHEDULE (NORMAL WEIGHT)
ELEMENT ASTM C33
AGGREGATE
CLASS
MAXIMUM
CHLORIDE
CONTENT
DRY UNIT
WEIGHT
MAX
AGGREGATE
SIZE
SLUMP
(NOTE 1)
AIR
CONTENT
FOUNDATIONS 145 PCF 3/4" 4"/8" 0.15%
MAX W/CM
RATIO
4,500 PSI 0.45 4S
0.55INTERIOR SOG 4,000 PSI 1 1/2" 4S 3% MAX 4"/8" 0.15%
1. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCING WHERE MORE THAN 12" OF FRESH CONCRETE IS
CAST BENEATH THE BAR.
2. Ld = THE STRAIGHT BAR DEVELOPMENT LENGTH
3. Ldh = THE HOOKED BAR DEVELOPMENT LENGTH
4. CASE 1: CLEAR SPACING OF BARS DEVELOPED OR SPLICED NOT LESS THAN db, CLEAR COVER NOT LESS
THAN db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM OR CLEAR SPACING OF BARS BEING DEVELOPED OR SPLICED NOT LESS THAN 2*db AND CLEAR COVER NOT LESS THAN db
5. CASE 2: REINFORCING BARS THAT DO NOT MEET THE REQUIREMENTS OF CASE 1
6. DEVELOPMENT LENGTHS ONLY APPLY TO THE OPPERATIONS AND SENTRY CONSTRUCTION.
TABLE 3 - CONCRETE REINF TENSION DEVELOPMENT LENGTHS (INCHES)
BAR
SIZE
#3
#4
#5
#6
TOP BARS OTHER BARS
UNCOATED BARS
4,000 PSI
f'c
145 PCF
Ld Ldh
HOOKED
BARS
LEAN CONCRETE FILL --------1,000 PSI 3/4" 4S -------- -------- 0.15%145 PCF
0.55CONCRETE ON STEEL DECK 4,000 PSI 3/4" 4S 6% 4"/8" 0.15%145 PCF
CASE 1 CASE 2 CASE 1 CASE 2
CRITICAL SECTION
Ld
Ldh
5%
TABLE 4 - POST-INSTALLED ANCHOR SCHEDULE
ANCHORING TO NORMAL WEIGHT CONCRETE
ANCHOR TYPE ANCHOR DIAMETER/
REBAR SIZE
MINIMUM EFFECTIVE
EMBEDMENT, UON
MECHANICAL 5/8" 4"
1/2" 3 1/4"
3/4" 4 3/4"
2 3/4"
3/4"
1/2"
4"
ADHESIVE
ULTIMATE DESIGN
SHEAR CAPACITY (KIP)
ULTIMATE DESIGN
TENSILE CAPACITY (KIP)
8.4 4.4
13.1 6.6
19 8.9
8.6 3.5
20.4 8.3
4,000 PSIWALLS 0.45 145 PCF 3/4" 4S 5% 4"/8" 0.15%
UNCOATED BARS
4,500 PSI
14 7
TOP BARS OTHER BARS
Ld Ldh
HOOKED
BARSCASE 1 CASE 2 CASE 1 CASE 2
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:5
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-003
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
M
AT
ER
IA
L
NO
TE
S
LP
12894093
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -0
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
SY
M
DE
SC
RI
PT
IO
N
DA
TE
A. TOP OF FIRST FLOOR SLAB, REFERENCE DATUM, IS ELEVATION 0' - 0".
REFER TO CIVIL FOR THE ACTUAL FLOOR ELEVATION.
B. T/FTG EL = [-2'-4"] UON.
C. TOP OF STRUCTURAL STEEL IS 5-INCHES BELOW THE TOP OF THE
CONCRETE ELEVATION INDICATED ON THE PLAN, UON.
D. REFER TO S-000 SERIES DRAWINGS FOR GENERAL NOTES, DESIGN LOADS
AND ABBREVIATIONS.
E. REFER TO S-500 SERIES DRAWINGS FOR TYPICAL DETAILS.
F. "WFx" CONTINUOUS TYPE WALL FOUNDATIONS. REFER TO S-601
GEOMETRY AND REINFORCEMENT INFORMATION. CENTER WALL
FOUNDATIONS ON WALL UNLESS NOTED OTHERWISE.
A
1 2
B
S-201 A1
S-201 C1
S-201 A3
S-201 C3
8"
20' - 0"
11' - 8" 3' - 5"
3'
- 1
0 1 /4"
8'
- 8
6' - 11" 3' - 4"
C1 S-501
TYP
TYP
S-510 C2
WF-1
W F-
WF-1
W F-
T/
FT
G -2
'-4
4' - 0"T/
FT
G -5
'-0
T/FTG -4'-0"
4'
- 0
T/FTG -5'-0"
T/FTG -2'-4"
T/FTG -4'-0"
4'
- 0
C1 S-510
A
1 2
B
S-201 A1
S-201 C1
S-201 A3
S-201 C3
W14X22
W14X22
W14X22
T/
CO
NC
LP
E
L 1 2'-
9"
SLOPE UP
8"
20' - 0"
C3 S-510
C3 S-510
SIM
B/
DE
CK
LP
E
L 1 2'-
4"
EQ
EQ
EQ
EQ
T/
CO
NC
H P
EL
'-7
B/
DE
CK
H P
EL
'-2
1 6" THICK SLAB-ON-GROUND W/ #4 @ 10" EW OVER VAPOR RETARDER OVER 6"
POROUS FILL
2 SLAB-ON-GROUND CONTRACTION JOINT
3 3 1/2" NLWT CONCRETE W/ 6X6 - W2.1XW2.1 WWR ON 1 1/2", 20 GAUGE
(0.0358"), COMPOSITE METAL DECK (5" TOTAL THICKNESS)
4 8" CAST-IN-PLACE CONCRETE WALL W/ #5@10" EACH WAY CENTERED IN
WALL
5 5 1/2" CAST-IN-PLACE CONCRETE STEM WALL AT PERIMETER OF STRUCTURE,
RE: C1/S-501
6 12"x12"CONCRETE PILASTER REINFORCED WITH 4-#7 (2 EF) W/ #3 TIES TOP 2
TIES SPACED @ 1 1/2", REMAINING SPACED @ 9", RE: C2/S-510
PLAN
NORTH
1/4" = 1'-0"
2' 4' 8' 12'
GENERAL SHEET NOTES
SHEET KEYNOTES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:5
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-101
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
FL
O
O R
RO
O F
PL
AN
S
LP
12894094
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -1
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
1/4" = 1'-0"A1 FOUNDATION & SLAB PLAN
1/4" = 1'-0"C1 ROOF FRAMING PLAN
SY
M
DE
SC
RI
PT
IO
N
DA
TE
FIRST FLOOR
0"
1 2
T/WALL
15' - 4"
7'
- 4
1/ 2"
8"
6' - 11" 3' - 4"
8" 20' - 0" 8"
C.
J.
NOTES:
1. C.J. INDICATES CONTROL JOINT LOCATIONS. AT CONTRACTOR'S OPTION, CONSTRUCTION JOINT MAY BE USED IN
LIEU OF CONTROL JOINT AT INDICATED LOCATIONS. REFER TO S-503 FOR CONTROL JOINT INFORMATION.
2. ALL REINFORCEMENT SHOWN IN ELEVATION IS SUPPLEMENTAL TO SCHEDULED REINFORCEMENT. REFER TO
S-101 FOR TYPICAL WALL REINFORCEMENT REQUIREMENTS.
1-#4x4'-0"
EF, TYP
0' -
ADDITIONAL 2-#5 @ 4"
OC ES OF OPENING
3"3"
3"
ADDITIONAL 2-#5 @ 4"
OC ABOVE OPENING
FIRST FLOOR
0"
A B
T/WALL
15' - 4"
8"20' - 8"8"
1' - 10" 1' - 0"
1' - 2" 8"
1 1
8" 1' - 4" 1' - 0" 1' - 8"
4" 2"
8" T
YP
0' -
NOTES:
1. C.J. INDICATES CONTROL JOINT LOCATIONS. AT CONTRACTOR'S OPTION, CONSTRUCTION JOINT MAY BE USED IN
LIEU OF CONTROL JOINT AT INDICATED LOCATIONS. REFER TO S-503 FOR CONTROL JOINT INFORMATION.
2. ALL REINFORCEMENT SHOWN IN ELEVATION IS SUPPLEMENTAL TO SCHEDULED REINFORCEMENT. REFER TO
S-101 FOR TYPICAL WALL REINFORCEMENT REQUIREMENTS.
TY
P8"
4"
RO
OF
M
EM
BR
AN
E
LO
W
P
OI
NT
(S
EE
A
RC
H)
2"
RO
OF
M
EM
BR
AN
E
LO
W P
OI
NT
(S
EE
A
RC
H)
FIRST FLOOR
0"
3'
- 6
T/WALL
15' - 4"
8"20' - 0"8"
8" 9'
- 4
3'
- 6
11' - 8"3' - 5"4' - 11"
C.J.
1-#4x4'-0"
EF, TYP
1' - 0"6' - 11"
1'
- 0
" 3'
- 8
T/PILASTER 13'-2"
0' -
4-#5 @ 4" OC
3-#5 @ 4" OC
3" 3"
3-#5 @ 4" OC
NOTES:
1. C.J. INDICATES CONTROL JOINT LOCATIONS. AT CONTRACTOR'S OPTION, CONSTRUCTION JOINT MAY BE USED IN
LIEU OF CONTROL JOINT AT INDICATED LOCATIONS. REFER TO S-503 FOR CONTROL JOINT INFORMATION.
2. ALL REINFORCEMENT SHOWN IN ELEVATION IS SUPPLEMENTAL TO SCHEDULED REINFORCEMENT. REFER TO
S-101 FOR TYPICAL WALL REINFORCEMENT REQUIREMENTS.
C4 S-510
FIRST FLOOR
0"
AB
3'
- 6
T/WALL
15' - 4"
8" 9'
- 4
3'
- 6
8" 20' - 8" 8"
8' - 8" 3' - 10 1/4" 8' - 1 3/4"
C.
J.
1-#4x4'-0"
EF, TYP
1' - 0" 2' - 4"
3'
- 8
1'
- 0 " 1
T/PILASTER 13'-2"
0' -
4-#5 @ 4" OC
3-#5 @ 4" OC
3-#5 @ 4" OC
NOTES:
1. C.J. INDICATES CONTROL JOINT LOCATIONS. AT CONTRACTOR'S OPTION, CONSTRUCTION JOINT MAY BE USED IN
LIEU OF CONTROL JOINT AT INDICATED LOCATIONS. REFER TO S-503 FOR CONTROL JOINT INFORMATION.
2. ALL REINFORCEMENT SHOWN IN ELEVATION IS SUPPLEMENTAL TO SCHEDULED REINFORCEMENT. REFER TO
S-101 FOR TYPICAL WALL REINFORCEMENT REQUIREMENTS.
4 C4 S-510
A. TOP OF FIRST FLOOR SLAB, REFERENCE DATUM, IS ELEVATION 0' - 0".
REFER TO CIVIL FOR THE ACTUAL FLOOR ELEVATION.
B. REFER TO S-000 SERIES DRAWINGS FOR GENERAL NOTES, DESIGN LOADS
AND ABBREVIATIONS.
C. REFER TO S-500 SERIES DRAWINGS FOR TYPICAL DETAILS.
1/4" = 1'-0"
2' 4' 8' 12'
GENERAL SHEET NOTES
SHEET KEYNOTES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:5
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-201
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
BU
IL
DI
NG
E
LE
VA
TI
O
NS
LP
12894095
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -2
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
1 REFER TO B3/S-503 FOR ADDITIONAL REINF AT WALL PENETRATIONS
2 DOOR OPENING, COORDINATE ROUGH OPENING REQUIREMENTS WITH
ARCHITECTURAL DRAWINGS
3 OPENING FOR ELECTRICAL DUCT BANK. COORDINATE SIZE AND LOCATION
WITH ELECTRICAL. REFER TO B3/S-503 FOR ADDITIONAL REINF AT WALL
PENETRATIONS
4 EMBEDDED C8x13.75 WITH A706 #5x2'-0" LONG ANCHOR CENTERED ON
CHANNEL @ 10", RE:C3/S-510
1/4" = 1'-0"C1 SOUTH ELEVATION
1/4" = 1'-0"C3 WEST ELEVATION
1/4" = 1'-0"A1 NORTH ELEVATION
1/4" = 1'-0"A3 EAST ELEVATION
SY
M
DE
SC
RI
PT
IO
N
DA
TE
3/4" CHAMFER,TYP
COMPACTED ASTM 12" GRADED
CRUSHED AGGREGATE BASE
COURSE, GRADATION NO.2 (PER UFGS
32 11 23)
NOTES:
1. COORDINATE PAD WITH CIVIL, ARCH, MECH, ELECT, PLUMB, & FIRE
PROTECT DRAWINGS AND EQUIPMENT MANUFACTURER'S
REQUIREMENTS
2. DO NOT FABRICATE REINFORCING, EXCAVATE, OR POUR CONCRETE
UNTIL EQUIPMENT SHOP DRAWINGS HAVE BEEN APPROVED.
3. AT CONTRACTOR'S OPTION, PAD MAY BE POURED SOLID 3'-2" BELOW
FINISHED GRADE, PROVIDE TOP AND BOTTOM LAYER OF #6@12" EACH
WAY IN LIEU OF #4@12" EW FOR THIS OPTION.
4" M
IN
6" 8"
FINISHED GRADE, SEE CIVIL
5" MIN
EQUIPMENT NOTE 1
#4 @ 12" EW T&B
COMPACT SUBGRADE BENEATH
PAD TO 95% PER ASTM D1557
#4 @ 12"
#4@12" CONT, 4 SIDES
NON-WOVEN FILTER FABRIC
3' -2
TYP
3" CLEAR,
8"
2" C
LE
AR NOTE 3
POST-INSTALLED ANCHORS, REFER
TO EQUIP SHOP DRAWINGS FOR
TYPE, SIZE, PROJECTION &
LOCATION. MIN 3" EMBED INTO SLAB
ROUGHEN SURFACE TO 1/4" AMPLITUDE
& APPLY BONDING AGENT
1 1 /2"
C
LR
M
IN4"
NOTES:
1. COORDINATE PAD WITH ARCH, MECH, ELECT, PLUMB & FIRE PROTECT
DRAWINGS AND EQUIP MANUFACTURER'S REQUIREMENTS.
2. SLAB REINF NOT SHOWN
3. DO NOT FABRICATE REINFORCING, EXCAVATE, OR POUR CONCRETE
UNTIL EQUIPMENT SHOP DRAWINGS HAVE BEEN APPROVED
3/4" CHAMFER, TYP
EQUIPMENT
6" MIN
#4 @ 12" EW
FIRST FLOOR
0"
T/ FTG EL
SEE PLAN
CL CONCRETE WALL, SEE PLAN
SP
LIC
E
CL
AS
S
B
LA
P
RE: SCHEDULE FOR
REINFORCEMENT
SOG, SEE PLAN
1/2" JT FILLER
INSULATION, SEE ARCH
VAPOR RETARDER
FACADE, SEE ARCH
RE
: S
CH
ED
UL
E
MI
N
1'
- 0
RE: SCHEDULE
TYP
1' - 0" MIN
GRADED CRUSHED AGGREGATE
BASE COURSE, GRADATION NO. 2
LOAD TRANSFER MAT AND RIGID
INCLUSIONS GROUND
IMPROVEMENT SYSTEM
CL WALL
INSULATION
4" AIRGAP W/
CONCRETE CURB REINFORCED
WITH #5@12" O.C. EACH WAY
8"
5 1/2"
NOTE: SEE SHEET B-101 FOR GROUND IMPROVEMENTS AT THE SENTRY BUILDING
3 MIN
WALL FOOTING
MATCH LONG FTG REINF
TH
IC
K
FT
G
2 x A
3'- 0"
M
AX
A
TH
IC
K
FT
G
1' - 6"
FOOTING REINF
APPROVED SUBGRADE
2 #5 IN CENTER OF WALL
2"TYP
1' - 6"
CONCRETE FORM, ID MIN 2" LARGER
THAN PIPE
UTILITY BENEATH THE WALL FOOTING
FILL PIPE TRENCH W/ LEAN CONC FILL UP
TO BOTTOM OF FOOTING
FOUNDATION WALL &
FOOTING, SEE PLAN
SECTION A-A
MI
N6"
1' - 0"
MIN
9"
A
A
NTSC3 EXTERIOR EQUIPMENT PAD
NTSC2 INTERIOR EQUIPMENT PAD DETAIL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:5
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-501
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
TY
PI
CA
L
FO
UN
DA
TI
O N
CO
NC
RE
TE
D
ET
AI
LS
LP
12894096
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -5
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
NTSC1 TYPICAL PERIMETER WALL FOOTING & SOG
NTSB1 STEPPED WALL FOOTING
NTSB2 PIPE BENEATH WALL FOOTING
SY
M
DE
SC
RI
PT
IO
N
DA
TE
SE
E
PL
AN
SL
AB
T
SEE PLAN FOR REINF
VAPOR RETARDER
6" MINIMUM CAPILLARY WATER
BREAK , COMPACTED #67 ASTM
C33 COURSE AGGREGATE
APPROVED SUBGRADE
T/SLAB
SEE PLAN
1 1 /4"
C
LR
SE
E
PL
AN
SL
AB
T
SEE PLAN FOR REINF
CUT REINF EACH SIDE OF JOINT
1 1/2" DEEP SAWCUT JOINT,
FILL WITH TRAFFIC GRADE SEALANT
T/SLAB
SEE PLAN
2" 2"
REFER TO C1/S-502 FOR
SLAB SUBGRADE
INFORMATION
FLOOR DRAIN
NOTE: SEE ARCH, MECH AND PLUMB FOR
DRAIN SIZE, TYPE, AND LOCATION
RADIUS = 2' - 0"
SLOPE DN SLOPE DN
REFER TO C1/S-502 FOR
SLAB SUBGRADE
INFORMATION
1/2” JOINT FILLER SEALANT &
BACKER ROD
CONC WALL
CONC SLAB-ON-GROUND
REFER TO C1/S-502 FOR
SLAB SUBGRADE
INFORMATION
3' - 0"
WALL REINF, MIN 2
CONT. BARS
CONTINUOUS WALL
FOOTING
45°
(1) #4
#4 @ RE-ENTRANT CORNERS
1'
- 6
1/2" JOINT FILLER
#4 @ 12"
REFER TO ARCH FOR
EXTERIOR WALL FINISHES
T/FTG
SEE PLAN
T/SLAB
SEE PLAN
SIDEWALK
SEE CIVIL
RE: PLAN FOR EXTENT
OF STEM WALLS AT
DOOR OPENINGS
REFER TO C1/S-502 FOR
SLAB SUBGRADE INFORMATION
VERTICAL WALL
REINF, RE: PLAN
THRESHOLD, SEE ARCH
JOINT SEALANT
1/2" PRE-FORMED
JOINT FILLER
PROTECTION BOARD,
SEE ARCH
AIR/VAPOR BARRIER,
SEE ARCH
#4 @ RE-ENTRANT CORNERS
NTSC1 SLAB-ON-GROUND
NTSC2 SLAB-ON-GROUND CONTRACTION JOINT
NTSB1 SLAB-ON-GROUND FLOOR DRAIN
NTSB2 ISOLATION JOINT @ WALLS
NTSB4 SOG @ EXTERIOR DOOR OPENINGS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:5
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-502
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
TY
PI
CA
L
SL
AB
-O N-
G
RO
UN
D
DE
TA
IL
S
LP
12894097
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -5
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
SY
M
DE
SC
RI
PT
IO
N
DA
TE
SPLICE BAR TO MATCH
SIZE AND SPACING OF
WALL REINFORCEMENT
TY
PI
CA
L
CL
AS
S B
LA
P
WALL
CENTERLINE
W
AL
L
CE
NT
ER
LIN
E
TY
P
2" C
OV
ER
PROVIDE ADDITIONAL BAR
MATCH SIZE OF WALL REINF 4"
1 -ADDITIONAL VERTICAL BAR AT
EACH SIDE OF CONTROL JOINT
INTERRUPT 1/2 OF HORIZONTAL
REINFORCEMENT AT CONTROL JOINT
1" DEEP FORMED JOINT
WALL
CENTERLINE
CONCRETE WALL
SEE PLAN
ROOF DECK
SEE PLAN
FASTEN DECK TO
ANGLE PER GENERAL
NOTES
CONT L6X4X5/16 (LLV)
DECK SPAN PERPENDICULAR TO WALL
EMBED PL 1/2"x12x1'-0" W/(4) - 1/2"⌀x4" HEADED
ANCHORS @ 3'-0" MAX,
CENTERED ON ANGLE 3/16
EMBED PLATE
2" 8" 2"
2" 8"
2"
TERMINATE HORIZONTAL
REINFORCEMENT AT WALL ENDS
USING 180° HOOK ORIENTED
VERTICALLY
WALL
CENTERLINE
2" COVER
ADDITIONAL BAR
AT ENDS
1 -ADDITIONAL VERTICAL BAR AT
EACH SIDE OF CONSTRUCTION JOINT
1" DEEP FORMED JOINT
WALL
CENTERLINE
CLASS B LAP SPLICE
NOTES:
1. PROVIDE 2 #4 DIAGONAL BARS AT CORNERS OF OPENINGS AND
EXTEND BAR Ld BEYOND BAR INTERSECTION.
2. PROVIDE REINFORCING EQUAL TO ONE HALF OF THE BARS CUT IN THE
SAME DIRECTION ON EACH SIDE OF OPENING BUT NOT LESS THAN 2 #4
BARS. EXTEND BARS 2'-0" PAST THE EDGE OF OPENING. OMIT THESE
BARS IF FRAMING IS PROVIDED TO SUPPORT THE OPENING.
3. DETAIL IS ONLY APPLICABLE WHERE SUPPLEMENTAL REINFORCEMENT
IS NOT SPECIFIED AT OPENINGS. REFER TO S-201 FOR ADDITIONAL
INFORMATION.
PIPE, DUCT, ETC OR INSULATION
OD SEE MEP DWGS FOR
SIZE AND LOCATION
ROUND, SQUARE, OR
RECTANGULAR OPENING
NOTE 2
NOTE 1
BRICK FACADE
SEE ARCH
CONCRETE WALL
SEE PLAN
L7x4x1/2 (LLH) EXTEND 1'-0"
BEYOND OPENING WITH
1/2"Ø SS EXPANSION
ANCHORS AT 8" SPACING
(NOTE 1)
2 1 /2"
NOTES:
1. COORDINATE PLACEMENT OF POST-INSTALLED ANCHORS SUCH THAT
NO WALL REINFORCEMENT IS DAMAGED DURING INSTALLATION. PLACE
FIRST ANCHORS 2-1/2" FROM EDGE OF SUPPORT ANGLE.
3/16
EMBED PL 1/2"x12x1'-0" W/(4) - 1/2"⌀x4" HEADED
ANCHORS @ 3'-0" MAX,
CENTERED ON ANGLE
(NOTE 1)
CONT L6X4X5/16 (LLV) W/
1/2"⌀x4" HEADED ANCHOR
@ 2'-0", CENTERED ON
ANGLE
EMBED PLATE
2" 8" 2"
2" 8"
2"
DECK SPAN PARALLEL TO WALL
NOTES:
1. ADJUST LAYOUT OF DECK SUPPORT EMBEDS WITHOUT EXCEEDING
MAXIMUM INDICATED SPACING TO PROVIDED CLEARANCE WITH BEAM
SUPPORT EMBED PER C2/S-504.
NTSC1 CONCRETE WALL AT CORNER
NTSC3 CONCRETE WALL CONTROL JOINT
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:0
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-503
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
TY
PI
CA
L
CO
NC
RE
TE
W
AL
L
DE
TA
IL
S
LP
12894098
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -5
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
NTSB2 DECK END BEARING ON CONCRETE WALL
NTSC2 CONCRETE WALL AT ENDS/JAMBS
NTSC4 CONCRETE WALL CONSTRUCTION JOINT
NTSB3 CONCRETE WALL OPENING
NTSB1 FACADE SUPPORT ANGLE AT OPENING
NTSB4 DECK END AT CONCRETE WALL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
NOTE: PROVIDE SECONDARY STEEL FRAMING AROUND OPENINGS & GROUPS OF OPENINGS GREATER THAN 12" (LEAST DIMENSION).
SECONDARY STEEL
FRAMING, C8x11.5 UON
SECTION A-A
2"
SHEET METAL POUR STOP
& DECK CLOSURE, TYP
CONC SLAB ON COMPOSITE
STEEL DECK 2'
- 6 " T
YP
1 #5 EACH SIDE
1 #5 x 2'-6" EACH CORNER
STRUCTURAL STEEL BEAM,
SEE PLAN
DECK SPAN
C8 x 11.5, UON
OPEN
PROVIDE STD HOOK WHEN
THE DISTANCE BETWEEN THE
OPENING AND THE EDGE OF
CONCRETE IS LESS THAN 2'-8"
A
A
SUPPORTCL SUPPORT CL
2"
1/2"x4-1/2x0'-9" SHEAR TAB WITH (3)-3/4"
BOLTS IN SHORT SLOTTED HOLES AT 3"
GAGE SPACING (NOTE 1)
1/2"x12x1'-0" EMBEDDED WITH (4)-3/4"Øx5" LONG HEADED
STUDS
1/4
1/2" SETBACK
NOTES:
1. PROVIDE SC-A BOLTS AT CONNECTIONS ALONG GRIDLINE 2.
1 1/2"
EMBED PLATE
2" 8" 2"
2" 8"
2"
1/4
2"
RE: B4/S-503
NTSC3 OPENINGS IN CONCRETE ON STEEL DECK SLABS
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:0
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-504
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
TY
PI
CA
L
ST
EE
L
DE
TA
IL
S
LP
12894099
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -5
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
NTSC2 SLOPING STEEL BEAM AT CONCRETE WALL
SY
M
DE
SC
RI
PT
IO
N
DA
TE
A
FORMSAVERS AT
CONTRACTOR'S OPTION RE: PLAN FOR
PILASTER INFORMATION
TYPICAL
CLASS B LAP
CONSTRUCTION JOINT AT
CONTRACTOR'S OPTION
T/WALL
15' - 4"
9'-4"
FACADE
SEE ARCH
CONCRETE WALL
SEE PLAN
L7x4x1/2 (LLH) EXTEND 1'-0" BEYOND
OPENING WITH 1/2"Ø SS EXPANSION
ANCHORS AT 8" SPACING (NOTE 1)
TERMINATE VERTICAL REINFORCEMENT
USING 180° AT EACH END AT OPENING,
HOOK ORIENTED PARALLEL TO WALL
SEE S-201 FOR ADDITIONAL REINF
REQUIREMENTS
2 3 /4"
NOTES:
1. COORDINATE PLACEMENT OF POST-INSTALLED ANCHORS SUCH THAT
NO WALL REINFORCEMENT IS DAMAGED DURING INSTALLATION. PLACE
FIRST ANCHORS 2-1/2" FROM EDGE OF SUPPORT ANGLE.
5/16
TYP
RE: S-201 FOR EMBEDDED CHANNEL
TOP AND BOTTOM
T/ FTG EL
SEE PLAN
CONCRETE PILASTER,
REFER TO PLAN
ISOLATION JOINT
SOG
SEE PLAN
T/ SLAB EL
SEE PLAN
FACADE, SEE ARCH
REFER TO PLAN, TYPICAL DETAILS,
AND SCHEDULE FOR ADDITIONAL
INFORMATION
CONCRETE CURB REINFORCED
WITH #5@12" O.C. EACH WAY
5 1/2"
INSULATION
4" AIRGAP W/
8"
CONCRETE WALL BELOW,
RE: PLAN
RE: PLAN FOR
PILASTER INFORMATION
3/8"x8" CONTINUOUS PLATE
FOR FULL HEIGHT OF
OPENING WITH 1/2"Øx5"
LONG HEADED STUDS AT 8"
AT EACH SIDE OF COLUMN
A
0 2'
3/4" = 1'-0"
6" 1' 4'
1/2" = 1'-0"
1' 2' 4' 6'
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:0
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-510
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
SE
CT
IO
NS
D
ET
AI
LS
LP
12894100
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -5
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
3/4" = 1'-0"C2 CONCRETE PILASTER ABOVE OPENING
1/2" = 1'-0"C3 SILL AND HEAD SECTION CUT
3/4" = 1'-0"C1 FOUNDATION AT PILASTER
3/4" = 1'-0"C4 CONCRETE PILASTER AT OPENING
SY
M
DE
SC
RI
PT
IO
N
DA
TE
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:0
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-601
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
SC
HE
DU
LE
S
LP
12894101
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -6
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
CONCRETE WALL FOOTING SCHEDULE
MARK
SIZE (UON) BOTTOM
REINFORCEMENT
TOP
REINFORCEMENT REMARKS
WIDTH THICKNESS LONG
BARS
SHORT
BARS
LONG
BARS
SHORT
BARS
WF-1 3' - 0" 1' - 4" 5 - #4 #5@6" 5 - #4 #5@6" TERMINATE SHORT REINFORCEMENT USING STANDARD HOOK, LAP CORNER
BARS USING L-BAR WITH TENSION LAP SPLICE AT EACH END OF BAR
SY
M
DE
SC
RI
PT
IO
N
DA
TE
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
8:
:1
AM
\\d c1 vs
\fe dp rj\
FD
ZE
\S
TR
U
\B
LD
G -1
-S
-B
IM
_v
_S
EN
TR
Y.
rv t
S-901
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
3D
IS
O M
ET
RI
C
VI
EW
S
LP
12894102
JH JT
05/27/2025
APPROVED BY LCDR ELIZABETH
OLOKODE NAVFAC NLON FEAD
DIRECTOR NEW LONDON, GROTEN, CT
SE
NT
RY
SMS/CWJ
1667770
GR
OT
ON
, C
ON
NE
CT
IC
UT
NA
VA
L S
UB
MA
RI
NE
B
AS
E
NE
W
LO
ND
ON
JWJ
NEK
HPN
M
ID
-A
TL
A N
TI
C
S -9
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
-M
ID
-A
TL
AN
TI
C N
A
VA
L S
TA
TI
O N
N
O R
FO
LK
, V A
C1 NORTHEAST ISOMETRIC C3 SOUTHWEST ISOMETRIC
NOTE: ISOMETRICS ARE PROVIDED FOR REFERENCE ONLY. DO NOT SCALE
FOR DIMENSIONS OR USE FOR CONSTRUCTION.
SY
M
DE
SC
RI
PT
IO
N
DA
TE
DOOR NUMBER
(REFER TO DOOR SCHEDULE)
DOOR TAG
ARCHITECTURAL SYMBOLS
WINDOW TYPE LETTER
WINDOW TYPE TAG
SPECIALITY ITEM NUMBER
SPECIALITY ITEM TAG
PARTITION TYPE DESIGNATION
(REFER TO PARTITION SCHEDULE)
PARTITION TYPE TAG
PARTITION IN PLAN
ROOM
A1 A-301
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
A-401 INTERIOR ELEVATION
TAG
INTERIOR ELEVATION NUMBER
SHEET WHERE DRAWN
EXTERIOR ELEVATION
TAG
ELEVATION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
A1 A-301
WALL / PARTIAL
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
A1 A-301
BUILDING SECTION
TAG
SECTION NUMBER
SHEET WHERE DRAWN
A1 A-301
BUILDING
NEW WORK
KEYNOTE TAG
KEYNOTE NUMBER
DEMO
KEYNOTE TAG
KEYNOTE NUMBER
A-901 PHOTOGRAPH TAG
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
A1
A-501
A1
A1
A1
B
A1
MATERIALS LEGEND
CONCRETE MASONRY UNIT
CAST-IN-PLACE CONCRETE
STEEL
BATT/LOOSE FILL INSULATION
RIGID INSULATION
WOOD - ROUGH
WOOD BLOCKING
EIFS - PAINTED
ARCHITECTURAL MASONRY
SECTION ELEVATION
CMU - PAINTED
GLAZED BLOCK
GLAZING
SPANDREL GLAZING / STEEL PANEL
CONCRETE FOUNDATION
EARTH / COMPACT FILL
POROUS FILL / GRAVEL
ARCHITECTURAL MASONRY UNIT
BRICK
GYPSUM BOARD
PLYWOOD
SAND / MORTAR / PLASTER
ACOUSTICAL TILE CEILING
CERAMIC TILE
FINISHED WOOD
PROTECTION BOARD
GENERAL SHEET NOTES
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P
AR
TM
E
N T
O F
TH
E
N A
VY
N
A
VA
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S
YS
TE
M
S C
O M
M A
N D
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
AS NOTED
1100 NORTH GLEBE ROAD
SUITE 500
ARLINGTON, VIRGINIA 22201
571.218.1000
FAX: 571.218.1600
6/
/2
4:
:2
PM
\\d c1 vs
\fe dp rj\
FD
ZE
\A
R C
H \B
LD
G
-1
-A -B
IM
_S
EN
TR
Y.
rv t
A-001
P-
W
EA
PO
NS
M
AG
AZ
IN
E
OR
DN
AN
CE
O
PE
RA
TIO
NS
F
AC
ILI
TY
AR
CH
IT
EC
TU
RA
L
NO
TE
S
AN
D
SY
M
BO
LS
WS
12894103
PS PS
05/27/2025
APPR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .