This file contains final design drawings and specifications for the P1102 Weapons Magazine and Ordnance Operations Facility at Naval Submarine Base New London in Groton, Connecticut. The drawings cover fire protection systems (including sprinkler systems designed per NFPA 13 and 2021 IBC standards, fire alarm/mass notification systems per NFPA 72, and associated controls), plumbing systems (domestic water, sanitary/vent, storm drainage, and radon mitigation), mechanical systems (HVAC including dedicated outside air unit with energy recovery, split-system air conditioning units, electric unit heaters, and associated controls), and electrical systems (power distribution, lighting, grounding, lightning protection, and equipment connections). The facility includes multiple operational support spaces such as bunks, toilets/showers, lockers, offices, training/conference room, mechanical room, electrical room, telecommunications room, arms room, and various support areas totaling approximately 11,100 square feet of roof area with an estimated connected electrical load of 191 kVA.

The design specifications require all systems to comply with applicable codes including the 2021 International Building Code, 2022 NFPA 13, 2021 NFPA 72, 2021 International Plumbing Code, and UFC standards for fire protection and antiterrorism. Building automation systems utilize direct digital control with BACnet MS/TP networking for HVAC equipment monitoring and control. The electrical infrastructure includes a 480Y/277V, 400-ampere main distribution panelboard with automatic transfer switch capability for standby generator operation, multiple 208/120V distribution panels, and comprehensive grounding and lightning protection systems. Fire suppression employs a wet-pipe automatic sprinkler system throughout with light and ordinary hazard classifications, backflow prevention, and fire department connection via 5-inch Storz fitting. Mechanical systems feature variable air volume terminal units, condensate pumps, and scheduled occupancy-based controls for energy efficiency, while plumbing incorporates reduced-pressure zone backflow prevention, thermostatic mixing valves, and radon mitigation collection and exhaust systems routed to roof level with inline fan operation.

View the file

Other files

File Type Posted
N4008526R00040014 SF 30.pdf PDF
N4008526R00040011 SF 30.pdf PDF
APPENDIX_D_Air Leakage Rate by Fan Pressurization.xlsx XLSX spreadsheet
ATTACHMENT H - Price Proposal Form REV4.docx DOCX document
APPENDIX_A_Air Leakage Test Form.docx DOCX document
APPENDIX_B_Air Leakage Test Results Form.docx DOCX document
APPENDIX_C_Test Agency Qualification Sheet.docx DOCX document
Amendment_0010_Drawings.pdf PDF
1667770spc07.28.26_rev.pdf PDF
ATTACHMENT U - NLON Soil Management SOP_JUN25.pdf PDF
N4008526R00040009 SF 30.pdf PDF
N4008526R00040008 SF 30.pdf PDF
P1102_Amend 0007_Drawings3of3.pdf PDF
P-1102_Amend 0007_Drawings2of3.pdf PDF
ATTACHMENT R - Geo Inv Analytical Rep.pdf PDF
ATTACHMENT Q - NRZ_Checklist-POAM_Items.pdf PDF
P-1102_Amend 0007_Drawings1of3.pdf PDF
ATTACHMENT S - UPDATED Wage Determination.pdf PDF
N4008526R00040007 SF 30.pdf PDF
JA ML-26-16 P1102 Interior Finishes_Redacted.pdf PDF
JA ML-26-15 P1102 Stormwater_Redacted.pdf PDF
JA ML-26-13 P1102 Fire Alarm_Redacted.pdf PDF
JA ML-26-12 P1102 ESS_Redacted.pdf PDF
ATTACHMENT N - NDDB Determination Renewal 16JAN2026.pdf PDF
ATTACHMENT L - Explosive Safety-HERO training.pptx PPTX presentation
P-1102_Amend 0006_Drawings_rev.pdf PDF
ATTACHMENT O - MK48 STORAGE FACILITY.pdf PDF
ATTACHMENT M - Permits Record of Decision (PROD).pdf PDF
UPDATED ATTACHMENT H Price Proposal Form REV1.docx DOCX document
P1102_Amend 0006_Specifications_rev.pdf PDF
N4008526R00040006 SF 30.pdf PDF
N4008526R00040005 SF 30.pdf PDF
Amendment 0004 PPIs.pdf PDF
Attachment K - P1102 Site Visit Log.pdf PDF
Amendment 0002 PPIs.pdf PDF
N4008526R00040002 SF 30.pdf PDF
Attachment I - Site Visit Map.pdf PDF
N4008526R00040001 SF 30.pdf PDF
Attachment D - Past Performance Questionnaire.pdf PDF
FINAL DESIGN_1667770dwg2of2Sentry.pdf PDF
FINAL DESIGN_1667770dwg2of4Site.pdf PDF
FINAL DESIGN_1667770dwg3of4Site.pdf PDF
P-1102_1667770spc1of3.pdf.pdf PDF
P-1102_1667770spc3of3.pdf.pdf PDF
Attachment C - Construction Experience Project Data.pdf PDF
Attachment G - Individual Small Business Subcontracting Plan.pdf PDF
FINAL DESIGN_1667770dwg1of3Operations.pdf PDF
FINAL DESIGN_1667770dwg1of4Site.pdf PDF
FINAL DESIGN_1667770dwg4of4Site.pdf PDF
Solicitation - N4008526R0004.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRST FLOOR

0' - 0"

ROOF MEMBRANE LP

16' - 0"

MAIN DRAIN PIPE

CONCRETE

SPLASH

BLOCK

C

FIRST FLOOR

0' - 0"

PIPE STANDS6" WATER LINE

THRUST BLOCKING PER NFPA 13

5" STORZ FDC

BFP TEST

HEADER WITH

(3) 2 1/2"

FIRE PROTECTION

WATER CONNECTION

(REFER TO CIVIL

DRAWINGS FOR

CONTINUATION)

6" BFP

MAIN TO BUILDING

POST

INDICATOR

VALVE

6" = 1'-0"

1" 2" 4" 6"

1/2" = 1'-0"

1' 2' 4' 6'

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 8:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FX501

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

S

UP

PR

ES

SI

O

N

RI

SE

R

AN

D

DE

TA

IL

S

JB

12894002

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FX

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/2" = 1'-0"B4 FIRE SUPPRESSION RISER DETAIL 1

1/2" = 1'-0"B2 FIRE SUPPRESSION RISER DETAIL 2

CHECK VALVE

OS&Y CONTROL VALVE

RISER CHECK

VALVE

WATERFLOW SWITCH

BACKFLOW PREVENTER

TEST CONNECTION

5" STORTZ CONNECTION

DOUBLE CHECK BACKFLOW

PREVENTER WITH OS&Y VALVES

NTSA1 FIRE PROTECTION RISER DIAGRAM

NTSC1 STORZ CONNECTION

6" = 1'-0"B1 PIPE STAND

CONTROL VALVE

REFER TO CIVIL DOCUMENTS BEYOND 5 FT

OUTSIDE OF THE BUILDING LINE

SY

M

DE

SC

RI

PT

IO

N

DA

TE

AP

PR

OPERATIONAL

SUPPORT

AWEPS OFFICE

SEA OFFICE

OFFICE

IDS MONITORING

TRAINING/

CONFERENCE

VESTIBULE

CORRIDOR

ELECTRICAL

TELECOM

MECHANICAL

COFFEE / MESS

SIPR OIS

OIS OFF

STORAGE

E6 BUNKS

E7 BUNKS

LOCKER

TOILETS /

SHOWER

TOILETS /

SHOWER

E7 BUNKS

LOCKER

E6 BUNKS

LACTATION

JAN

ELEC

OH

OH

OH

OH

OH

OH

B2

FX501

B4

FX501

OH

WASHER/ DRYER

WEAPONS

OFFICER

ARMS ROOM

A

B

C

2 3 4 6 7 85

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 8:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FX101

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

S

UP

PR

ES

SI

O

N

FL

O O

R

PL

AN

JB

12894001

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FX

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/8" = 1'-0"B1 FIRST FLOOR PLAN - FIRE SUPPRESSION

A. REFER TO SHEET FX001 FOR GENERAL NOTES, SYMBOLS, AND

ABBREVIATIONS.

B. ALL AREAS LIGHT HAZARD UNLESS OTHERWISE NOTED.

C. SPRINKLER PIPE MUST NOT BE LOCATED ABOVE ELECTRICAL EQUIPMENT

(PANEL BOARDS, SWITCH BOARDS, SWITCH GEAR MOTOR CONTROLLERS,

ETC.)

1. BACKFLOW PREVENTER TEST HEADER.

2. 5" STORTZ FIRE DEPARTMENT CONNECTION.

3. PROVIDE A SINGLE PIPE PENETRATION FOR SPRINKLERS PROTECTING THE

ARMORY.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

GENERAL NOTES AND SYMBOLS

FIRE SPRINKLER SYMBOLS FIRE SPRINKLER NOTES

(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

PROVIDE A COMPLETE AUTOMATIC WET-PIPE FIRE SUPPRESSION

SPRINKLER SYSTEM THROUGHOUT THE FACILITY, DESIGNED AND

PROVIDED IN ACCORDANCE WITH APPLICABLE CODES:

- INTERNATIONAL BUILDING CODE (IBC) (2021 EDITION)

- NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS

(2022 EDITION)

VERIFY LOCATIONS AND MEASUREMENTS AS CONDITIONS MAY VARY

THROUGHOUT CONSTRUCTION. CHANGES FROM THE ORIGINAL DESIGN

MUST BE APPROVED BY THE FPDOR.

PROVIDE TAMPER AND FLOW SWITCHES. CONNECTIONS TO THE FIRE

ALARM SYSTEM'S SIGNALING LINE CIRCUIT MUST BE MADE UNDER

SPECIFICATION DIVISION 28 31 76.

WATER FLOW TEST DATA IS PROVIDED TO SHOW HYDRAULIC

CALCULATIONS AND DETERMINE PIPE SIZING. WATER FLOW TEST TO BE

USED FOR INFORMATION ONLY. CONTRACTOR TO PROVIDE WATER FLOW

TEST.

OBTAIN REQUIRED PERMITS AND APPROVALS FROM THE AHJ PRIOR TO

COMMENCING WORK.

HYDRAULICALLY CALCULATE THE SPRINKLER SYSTEM PER NFPA 13

DENSITY AND SPACING LISTED IN THE SPRINKLER DESIGN CRITERIA TABLE

BELOW. FIELD VERIFY SYSTEM DESIGN AND LAYOUT PRIOR TO

FABRICATION OR INSTALLATION.

PROVIDE PIPE HANGERS ON FIRE SPRINKLER SYSTEM PIPING AND

EQUIPMENT PER NFPA 13.

SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE AND ROOM

USE. SEE ARCHITECTURAL, ELECTRICAL, MECHANICAL, AND

TELECOMMUNICATIONS PLANS FOR THE LOCATION OF CEILING-MOUNTED

DEVICES. FIELD VERIFY AND COORDINATE THE LOCATIONS OF SYSTEM

COMPONENTS INCLUDING PIPING, ALARMS, DRAINS, TEST POINTS, ETC.

WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND ELECTRICAL

EQUIPMENT WITHIN THE BUILDING.

PROVIDE AUXILIARY DRAINAGE WITH A DRAIN VALVE AND PLUG FOR

TRAPPED SECTION OF PIPE, PER NFPA 13.

THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN

LAYOUT AS GUIDANCE FOR THE PLANNING OF THE FIRE SPRINKLER

SYSTEM. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL

FROM THE FIRE PROTECTION DESIGN OF RECORD AND AHJ PRIOR TO

INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS FOR

ADDITIONAL EQUIPMENT NECESSARY TO PROVIDE A COMPLETE

INSTALLATION.

PIPE MAIN DRAIN TO OUTSIDE OF BUILDING. PROVIDE SPLASH BLOCK.

ALL SPRINKLERS INSTALLED IN FINISHED CEILINGS MUST BE CONCEALED

TYPE.

SPRINKLER DESIGN CRITERIA

GENERAL ROOM/AREA

CLASSIFICATION

OCCUPANCY

CLASSIFICATION

DENSITY

REQUIREMENTS

DURATION OF

SUPPLY

MAXIMUM

SPRINKLER PROTECTION

AREA

SPRINKLER

TEMPERATURE

ABBREVIATIONS

TEST DATE: 9/28/2022 BY: JACOBS FPE

STATIC PRESSURE: 99 PSI

RESIDUAL PRESSURE: 93 PSI

1320 GPMDISCHARGE FLOW:

ORDINARY HAZARDOH

GAUGE HYDRANT #:

FLOW HYDRANT #:

WATERFLOW TEST DATA

AFF

AHJ

AVG

BFP

CFM

CO

COTR

ELEV

FD

FDC

FHV

FPDOR

FVC

GALS

GPH

GPM

GV

MIN

NC

NIC

NP

OS&Y

PSIG

QFPE

SOV

SQFT

UH

VLV

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

AVERAGE

DOUBLE CHECK VALVE BACKFLOW PREVENTER

CUBIC FEET PER MINUTE

CONTRACTING OFFICER

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

ELEVATION

FLOOR DRAIN

FIRE DEPARTMENT CONNECTION

FIRE HOSE VALVE

FIRE PROTECTION DESIGNER OF RECORD

FIRE VALVE CABINET

GALLONS

GALLONS PER HOUR

GALLONS PER MINUTE

GATE VALVE

MINIMUM

NONCOMBUSTIBLE

NOT IN CONTRACT

NOT PERMITTED

OUTSIDE SCREW & YOKE

POUNDS PER SQUARE INCH GAUGE

QUALIFIED FIRE PROTECTION ENGINEER

SOLENOID VALVE

SQUARE FEET

UNIT HEATER

VALVE

OFFICES, RESTROOMS,

CORRIDORS, BREAKROOM, BUNK

ROOMS

MECHANICAL ROOM,

TELECOM ROOM, STORAGE,

ARMORY

LIGHT

HAZARD

ORDINARY

HAZARD

0.10 GPM/SQFT

1,500 SQFT

SPRINKLER: K5.6

0.20 GPM/SQFT

2,500 SQFT

SPRINKLER: K8.0

60 MINUTES

60 MINUTES

225 SQFT

130 SQFT

ORDINARY

ORDINARY

HOSE

ALLOWANCE

250 GPM

250 GPM

INSPECTOR'S TEST CONNECTION/AUXILIARY DRAIN

WET SYSTEM RISER

WALL-MOUNTED STORZ FIRE DEPARTMENT CONNECTION

DIRECTION OF SLOPE DOWN

PRESSURE CONTROL VALVE

POINT OF NEW CONNECTION TO EXISTING PIPING

MISCELLANEOUS

TEST PORT

RELIEF VALVE

GATE VALVE

CHECK VALVE

ECCENTRIC REDUCER

TEE OUTLET DOWN

TEE OUTLET UP

CONCENTRIC REDUCER

UNION

ELBOW DOWN

VALVE IN DROP

VALVE IN CENTER DROP

VALVE IN RISE

PIPING SYMBOLS

DIRECTION OF FLOW

ELBOW UP

PRESSURE GAUGE WITH GAUGE COCK

STRAINER WITH BLOWDOWN VALVE

FIRE SPRINKLER ZONE/ FLOOR CONTROL VALVE ASSEMBLY

SPRINKLER SYMBOLS

PENDENT SPRINKLER, STANDARD TEMPERATURE

UPRIGHT SPRINKLER, STANDARD TEMPERATURE

SIDEWALL SPRINKLER, STANDARD TEMPERATURE

DRY PENDENT SPRINKLER, STANDARD TEMPERATURE

PENDENT SPRINKLER, HIGH TEMPERATURE

UPRIGHT SPRINKLER, HIGH TEMPERATURE

PITOT PRESSURE: 62 PSI

NOTE: REFER TO G-103 FOR SITE PLAN SHOWING FIRE HYDRANT LOCATIONS

AND WATER DISTRIBUTION SYSTEM PIPING.

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 8:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FX001

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

S

UP

PR

ES

SI

O

N

SY

M

BO

LS

, L

EG

EN

D, A

BB

RE

VI

AT

IO

NS

A

ND

N O

TE

S

JB

12894000

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FX

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

SY

M

DE

SC

RI

PT

IO

N

DA

TE

FIRE ALARM / MASS NOTIFICATION SYSTEM GENERAL NOTES

1. DESIGN, PROVIDE, AND COMMISSION THE FIRE ALARM/ MASS NOTIFICATION SYSTEM IN ACCORDANCE WITH APPLICABLE CODES:

- NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE (2021 EDITION)

- INTERNATIONAL BUILDING CODE (IBC) (2021 EDITION)

- UFC 3-600-01, FIRE PROTECTION ENGINEERING FOR FACILITIES (CHANGE 6, MAY 2021)

- UFC 4-010-01, DOD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS (CHANGE 2, 30 JULY 2022)

- UFC 4-021-01, DESIGN AND O&M: MASS NOTIFICATION SYSTEMS (CHANGE 1, JANUARY 2010)

2. THESE DOCUMENTS DEPICT A PERFORMANCE LEVEL ENGINEERING DESIGN LAYOUT AS GUIDANCE FOR THE PLANNING OF THE SYSTEM. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE ENGINEER OR RECORD AND THE AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION. INCLUDE IN THE SHOP DRAWINGS AND CALCULATIONS FOR ADDITIONAL EQUIPMENT NECESSARY, INCLUDING INITIATING DEVICES AND NOTIFICATION APPLIANCES, TO PROVIDE A COMPLETE INSTALLATION AND COMPLY WITH LOCAL CODES, AMENDMENTS AND BASE STANDARDS.

3. FOR COMPLETE SYSTEM CONTROL, REFER TO THE MATRIX OF OPERATION WITHIN THIS PACKAGE.

4. PROVIDE AN ADDRESSABLE FIRE ALARM/MASS NOTIFICATION SYSTEM CONTROL PANEL WITH RADIO ALARM TRANSMITTER TO TRANSMIT ALARM, TROUBLE, AND SUPERVISORY SIGNALS TO THE BASE FIRE ALARM REPORTING SYSTEM. PROVIDE ADDITIONAL MASS NOTIFICATION INTERFACE PANEL TO ACCEPT SIGNALS TO BROADCAST VOICE MESSAGES WITHIN THE FACILITY. MASS NOTIFICATION INTERFACE PANEL MUST BE COMPATIBLE

WITH THE EXISTING BASEWIDE MASS NOTIFICATION SYSTEM.

5. FINAL FIRE ALARM/MASS NOTIFICATION SYSTEM TEST AND PRE-TEST MUST BE WITNESSED BY THE QFPE. FILE A "RECORD OF COMPLETION" PREPARED IN ACCORDANCE WITH NFPA 72, AND THE FIRE ALARM TEST REPORT WITH THE FPDOR AND AHJ.

6. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES MUST NOT EXCEED 2 FLASHES PER SECOND, NOR BE LESS THAN 1 FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION MUST BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40%, IN ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES MUST BE SPACED IN ACCORDANCE WITH NFPA 72. STROBES MUST

BE SYNCHRONIZED.

7. AUDIBLE FIRE ALARM SOUND LEVELS MUST BE AT LEAST 15dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. PROVIDE NOTIFICATION APPLIANCES THROUGHOUT THE FACILITY TO MEET THE NFPA 72 REQUIREMENTS.

8. SPRINKLER SYSTEM TAMPER AND FLOW SWITCHES PROVIDED UNDER SPECIFICATION SECTION 21 13 13. CONNECT DEVICES TO THE

FIRE ALARM SIGNALING LINE CIRCUITS.

9. OBTAIN APPROVALS FROM THE FPDOR AND AHJ PRIOR TO COMMENCING WORK.

10. DO NOT LOCATE DETECTORS IN DIRECT AIR FLOW OR CLOSER THAN 3 FEET FROM AN AIR SUPPLY OR RETURN DIFFUSER.

11. MOUNT WALL-MOUNTED VISUAL AND VISUAL/AUDIBLE NOTIFICATION APPLIANCES WITH THE ENTIRE STROBE LENS BETWEEN 80" TO 96"

ABOVE THE FINISHED FLOOR.

12. FIRE ALARM SIGNALING LINE CIRCUITS (SLC) AND NOTIFICATION APPLIANCE CIRCUITS (NAC) ARE CLASS B. T-TAPS AND WIRE NUTS

ARE NOT PERMITTED.

13. THE INTENT OF THE SPEAKER SPACING IS TO PROVIDE A COMMON INTELLIGIBILITY SCALE (CIS) SCORE TO MEET THE MINIMUM INTENT OF UFC 4-021-01. THE INSTALLING CONTRACTOR MUST VERIFY THEIR DESIGN MEETS THIS INTENT EITHER BY PROVIDING SPEECH INTELLIGIBILITY CALCULATION BASED ON THE PROVIDED PRODUCTS' THEORETICAL Q AND DIRECTIVITY INDEX OR BY ADDING SPEAKERS THROUGH TESTING.

MINIMUM CIS VALUE IN EACH AREA WHERE OCCUPANTS ARE LOCATED IS 0.7

14. PROVIDE SURGE SUPPRESSION ON FIRE ALARM AND MASS NOTIFICATION CIRCUITS LEAVING THE BUILDING ENCLOSURE AND ON 120VAC CIRCUITS TO CONTROL PANELS, SUBPANELS, TRANSMITTERS, AMPLIFIER PANELS, AND BOOSTER PANELS IN ACCORDANCE WITH UL 1449 AND

UL 1283. SURGE SUPPRESSION IS NOT REQUIRED FOR EXTERIOR WALL MOUNTED DEVICES.

FIRE ALARM / MASS NOTIFICATION ABBREVIATIONS

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

AUTONOMOUS CONTROL UNIT

AVERAGE

CONTRACTING OFFICER

CONTRACTING OFFICER REPRESENTATIVE

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

DESIGNATED FIRE PROTECTION ENGINEER

ELEVATION

END OF LINE RESISTOR

FIRE PROTECTION DESIGNER OF RECORD

INITIATING DEVICE CIRCUIT

MAXIMUM

MINIMUM

NOTIFICATION APPLIANCE CIRCUIT

NOT IN CONTRACT

NOT PERMITTED

NONCOMBUSTIBLE

QUALIFIED FIRE PROTECTION ENGINEER

SIGNALING LINE CIRCUIT

SQUARE FEET

TYPICAL

WEATHERPROOF

AFF

AHJ

ACU

AVG

CO

COR

COTR

DFPE

ELEV

EOL

FPDOR

IDC

MAX

MIN

NAC

NIC

NP

NC

QFPE

SLC

SQFT

TYP

WP

FIRE ALARM/MASS NOTIFICATION SYMBOLS

VISUAL TEXT DISPLAY

REMOTE ANTENNA

"WP"

ANNUNCIATOR PANEL

RADIO ALARM TRANSMITTER - FIRE ALARM

ANN

RAT

MM

LOCAL OPERATING CONSOLE

PHOTOELECTRIC SMOKE DETECTOR

NOTIFICATION APPLIANCE CONTROL PANELNAC

CONTROL MODULECM

DUCT SMOKE DETECTOR (S - SUPPLY; R - RETURN)

WALL-MOUNTED FIRE ALARM SPEAKER

MONITOR MODULE

DESIGNATES WEATHERPROOF BACKBOX AND DEVICE

KB KNOX BOX

FIRE SUPPRESSION CONTROL VALVE TAMPER SWITCH

FMCU FIRE ALARM / MASS NOTIFICATION PANEL

CARBON MONOXIDE DETECTOR

F MANUAL PULL STATION

TS

C

R

S

LOC

CO

VTD

P

WATER FLOW SWITCH

WF

C

COMBINATION FIRE ALARM / MASS NOTIFICATION SPEAKER STROBE

WITH CLEAR LENS (CEILING MOUNTED)

(XX DENOTES MINIMUM CANDELA RATING)XX

WALL-MOUNTED FIRE ALARM SPEAKER STROBE

SURGE PROTECTIVE DEVICESPD

VTDC VISUAL TEXT DISPLAY CONTROLLER

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 7:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FA001

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

A

LA

RM

A

ND

M

AS

S

NO

TI

FI

CA

TI

O

N

SY

M

BO

LS

, L

EG

EN

D, A

BB

RE

VI

AT

IO

NS

A

ND

NO

TE

S

JB

12894003

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FA

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

SY

M

DE

SC

RI

PT

IO

N

DA

TE

P

P

P

P

177 15

15 F

F F

F F

F

F

F

F

P

ANN

30 75

FMCUNACRAT

P

P

LOC

30 30

P30

TRAINING/

CONFERENCE

VESTIBULE

101CORRIDOR

ELECTRICAL

MECHANICAL

TELECOM

COFFEE / MESS

STORAGE

WEAPONS

OFFICER

SIPR OIS

OIS OFF

IDS MONITORING

OFFICE

SEA OFFICE

AWEPS OFFICE

OPERATIONAL

SUPPORT

JAN

LACTATION

ELEC

LOCKER

E7 BUNKS

E6 BUNKS

TOILETS /

SHOWER

TOILETS /

SHOWER

E7 BUNKS

LOCKER

E6 BUNKS

WF

C

TS

C

VTD

VTD

VTDVTD

VTD

VTD

VTD

VTD VTD

WASHER/ DRYER

ARMS ROOM

15, WP

15, WP

WP WP

WP

WP

WP

S

MM MM

TS

C

TS

C

CM

CM

CM

CM

CMCMCM

CM

CM

CM

CM

CM

CM

CM

MMMM

A

B

C

2 3 4 6 7 85

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 7:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FA101

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

A

LA

RM

A

ND

M

AS

S

NO

TI

FI

CA

TI

O

N

FL

O O

R

PL

AN

JB

12894004

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FA

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/8" = 1'-0"B1 FIRST FLOOR PLAN - FIRE ALARM / MASS NOTIFICATION SYSTEM

1. DESIGNATED SPACE FOR FIRE ALARM EQUIPMENT.

2. RADIO ALARM TRANSMITTER ANTENNA MOUNTED AT

ROOF LEVEL.

3. RECESSED LOC AND REMOTE ANNUNCIATOR MAY BE COMBINED INTO A

SINGLE UNIT PROVIDED THE MICROPHONE IS ACCESSIBLE TO BUILDING

OCCUPANTS WHILE THE FIRE ALARM FUNCTIONS REMAIN INACCESSIBLE.

4. GREY SHADING TO SHOW FIRE PROTECTION BLOCKOUT.

5. CONTROL MODULE FOR PUBLIC ADDRESS SYSTEM. REFER TO T- 201 FOR

LOCATION OF PA SYSTEM CONTROLS

6. CONTROL MODULE FOR LIGHTING CONTROLS.

A. REFER TO FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

FMCU

LOC

ROOF

NOTE: RISER DIAGRAM IS A SCHEMATIC REPRESENTATION OF

THE FIRE ALARM/ MASS NOTIFICATION SYSTEM. REFER TO THE

FIRE ALARM/ MASS NOTIFICATION PLANS FOR LOCATIONS AND

QUANTITIES OF DEVICES AND APPLIANCES.

ELEC. 103 RAT

ELEC. 103 ANN

VESTIBULE 101

ANTENNA

VTD

120V BATTNAC - FA/MNS STROBE

NAC - FA/MNS SPEAKER

CLASS B

CLASS B

EOL

EOL

SLC - INITIATING

CLASS BCMF

P

MMMM

TS

C

WF

C

EOL

WP

120V

A. THE DESIGN SHOWN IS A PERFORMANCE DESIGN ILLUSTRATING GENERAL

DESIGN CRITERIA ONLY. PROVIDE ALL ADDITIONAL EQUIPMENT REQUIRED

TO COMPLETE THE SYSTEM FOR COMPLIANCE WITH ALL APPLICABLE

CODES.

B. ALL CIRCUITS MUST BE IN MINIMUM 3/4" CONDUIT.

SPD

SPD

VTDC

CMEOL CM

PUBLIC ADDRESS

SYSTEM

LIGHTING

CONTROLS

3' (MIN) 4" (MIN)

12" (MAX)

4" (MIN)

MOUNT THE VISUAL LENS WITHIN 6"

OF THE CEILING FOR THE CEILING

HEIGHT IS LESS THAN 96" AFF.

TO EXIT

DOOR

5' (MAX)

44" MAX TO

OPERATING

HANDLE

TWO OR MORE

APPLIANCES IN ANY

FIELD OF VIEW MUST

BE SYNCHRONIZED

90"

WALL MOUNTED

SMOKE DETECTOR

CEILING MOUNTED

SMOKE DETECTOR

SUPPLY OR

RETURN

DIFFUSER

CEILING

FINISHED FLOOR

VISUAL WALL

MOUNTED

APPLIANCE

AUDIBLE

ONLY WALL

MOUNTED

APPLIANCE

MINIMUM 12"

FROM LIGHT

SWITCH

PULL STATIONS MUST NOT BE

LOCATED BEHIND DOOR SWINGS.

FIRE ALARM/

MASS

NOTIFICATION

PANEL

(FMCU)

IN

ST

AL

L F

MC

U

NO

G

RE

AT

ER

T

HA

N

" A

FF

AREA/ ROOM SMOKE DETECTOR

DUCT SMOKE DETECTOR

WATER FLOW SWITCH

MANUAL PULL STATION

MONITOR SWITCH (FIRE SUPPRESSION VALVE TAMPER SWITCH)

BUNK ROOM SMOKE DETECTOR

1.

2.

3.

4.

5.

6.

7.

8.

9.

SYSTEM INPUTS

GE

NE

RA

L E

VA

CU

AT

IO

N

FI

RE

A

LA

RM

MA

SS

N

OT

IF

IC

AT

IO

N

GE

NE

RA

L A

LA

RM

OU

TP

UT

T

O

EM

ER

GE

NC

Y

RE

CI

EV

ER

AU

DI

BL

E

VI

SU

AL

A

LA

RM

S

IG

NA

L A T

FA

CP

AU

DI

BL

E

VI

SU

AL

T

RO

UB

LE

S

IG

NA

L A

T

FA

CP

RE

CO

RD

E

VE

NT

S

IN

M

EM

OR

Y

OU

TP

UT

S

IG

NA

L T O

SH

UT

D

OW

N

AI

R

HA

ND

LIN

G

UN

IT

AU

DI

BL

E

VI

SU

AL

S

UP

ER

VI

SO

RY

S

IG

NA

L A

T

FA

CP

A B C D E F G H I J

A B C D E F G H I J

SYSTEM OUTPUTS

INDICATES ACTION WILL CAUSE A SPECIFIC RESULT

INDICATES ACTION WILL NOT CAUSE A SPECIFIC RESULT

MATRIX OF OPERATIONS

K

K

OV

ER

RI

DE

G

EN

ER

AL

F

IR

E

AL

AR

M

DI

SP

LA

Y

DE

VI

CE

O

N

AN

NU

CI

AT

OR

P

AN

EL

AC

TI

VA

TE

E

XT

ER

IO

R

ST

RO

BE

A

T

FD

R

ES

PO

NS

E

PO

IN

T

MASS NOTIFICATION IN- BUILDING EVENT

MASS NOTIFICATION - AHU SHUTDOWN SWITCH (AT FMCU/ACU

AND LOC)

MASS NOTIFICATION - INPUT SIGNAL FROM BASE SYSTEM

L

L

M

M

OV

ER

RI

DE

P

UB

LIC

A

DD

RE

SS

S

YS

TE

M

AC

TI

VA

TE

E

GR

ES

S

LIG

HT

IN

G

PLAN

NORTH

GENERAL SHEET NOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:3 7:

A

M \\d c1 vs

\fe dp rj\

FD

ZE

\F

PR

O \B

LD

G

-1

-F -B

IM

_v

.rv t

FA501

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

FI

RE

A

LA

RM

A

ND

M

AS

S

NO

TI

FI

CA

TI

O

N

RI

SE

R

DI

AG

RA

M

, M

AT

RI

X, A

ND

D

ET

AI

LS

JB

12894005

JM CL

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

HPN

HPN

M

ID

-A

TL

A N

TI

C

FA

1 NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

NTSC2 FIRE ALARM RISER DIAGRAM

NTSA1 DETAIL - TYPICAL DEVICE MOUNTING DETAIL

NTSB1 FIRE ALARM MATRIX OF OPERATION

SY

M

DE

SC

RI

PT

IO

N

DA

TE

DOMESTIC HOT WATER PIPNG

DOMESTIC COLD WATER PIPING

DOMESTIC HOT WATER RETURN PIPING

SOIL, WASTE OR SANITARY SEWER PIPING

VENT PIPINGV

SS

DHWR

DHW

DCW

THIN LINE WEIGHT INDICATES EXISTING ITEM TO REMAIN

HEAVY LINE WEIGHT INDICATES NEW WORK TO BE PROVIDED

HEAVY DASHED LINE WEIGHT INDICATES EXISTING

ITEM TO REMOVE, REFER TO DEMOLITION NOTES

DOWNWARD SLOPE

FLANGE

AUTOMATIC AIR VENT

ECCENTRIC REDUCER

MANUAL AIR VENT

PIPE CAP

PIPE DOWN

CONCENTRIC REDUCER

PIPE UP

FLOOR CLEAN OUT

FCO

FLOOR DRAIN

FD

PRESSURE GAUGE WITH SHUTOFF COCK

STRAINER WITH BLOWDOWN VALVE

UNION

WALL CLEAN OUT

POINT OF CONNECTION

POINT OF DISCONNECTION

WYE STRAINER

CHECK VALVE

AUTOMATIC BALANCING VALVE

BACKFLOW PREVENTER

3-WAY VALVE

2-WAY VALVE

BUTTERFLY VALVE

DRAIN VALVE

GATE VALVE

GLOBE VALVE

ISOLATION VALVE

MANUAL FLOW CONTROL BALANCING VALVE

PRESSURE REDUCING VALVE

RELIEF VALVE

SOLENOID VALVE

SQAURE HEAD BALANCING VALVE

TEMPERATURE PRESSURE RELIEF VALVE

SECTION, DETAIL OR ELEVATION

IDENTIFICATION MARK

PLATE NUMBER WHERE SECTION,

DETAIL OR ELEVATION IS TAKEN

SECTION, DETAIL OR

ELEVATION TITLE

PLATE NUMBER WHERE

DETAIL IS DRAWN

DETAIL NUMBER

DETAIL CALLOUT SYMBOL SECTION CUT SYMBOL

SECTION LETTER

PLATE NUMBER WHERE

SECTION IS DRAWN

VIEW SECTION

XX

X-XXX XX

X-XXX

XX

X-XXX

DETAIL/SECTION TITLE

W WATER METER

WATER PUMP

M GAS OR WATER METER

COMPRESSED AIR PIPINGCA

RAIN LEADER - PRIMARY STORM DRAINAGESD

RAIN LEADER - OVERFLOW STORM DRAINAGEOFD

RADON MITIGATION PIPINGR

PLUMBING FIXTURES OR EQUIPMENT BY OTHERS

(ICE) (REF)

BALL VALVE

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 2:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-001

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

L

EG

EN

D

AN

D

G

EN

ER

AL

N O

TE

S

MJL

12894006

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -0

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

ABA ARCHITECTURAL BARRIERS ACT

ADA AMERICANS WITH DISABILITIES ACT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AMI ADVANCED METERING INFRASTRUCTURE

BF BELOW FLOOR

BFF BELOW FINISHED FLOOR

BTUH BRITISH THERMAL UNIT PER HOUR

BV BALANCING VALVE

CLG CEILING

CO CLEANOUT

COR CONTRACTING OFFICER'S REPRESENTATIVE

CV CHECK VALVE

DCP DOMESTIC HOT WATER CIRCULATING PUMP

DCW DOMESTIC COLD WATER

DFU DRAINAGE FIXTURE UNITS

DHW DOMESTIC HOT WATER

DHWH DOMESTIC HOT WATER HEATER

DHWR DOMESTIC HOT WATER RECIRCULATION

DIAM. DIAMETER

DN DN

DWV DRAIN, WASTE, VENT

EA EACH

ELEV ELEVATION

ET EXPANSION TANK

EWC ELECTRIC WATER COOLER

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FLA FULL LOAD AMPS

FT FEET

GAL GALLON

GFCI GOVERNMENT FURNISHED, CONTRACTOR INSTALLED

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

H x W HEIGHT AND WIDTH

HB HOSE BIBB

HP HORSEPOWER

I.E. INVERT ELEVATION

IM ICE MAKER

IN. INCHES

IN. WC INCHES OF WATER COLUMN

KS KITCHEN SINK

KW KILOWATTS

LAV OR L LAVATORY

MAX MAXIMUM

MIN MINIMUM

MS MOP SINK

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

NFHB NON-FREEZE HOSE BIBB

PH PHASE

PSI POUNDS PER SQUARE INCH

R RADON MITIGATION PIPING

REF REFRIGERATOR

RF RADON FAN

RL ROOF LEADER

RPM REVOLUTIONS PER MINUTE

RPZ REDUCED PRESSURE ZONE BACKFLOW PREVENTER

SAN OR SS SANITARY

SF SQUARE FEET

SH SHOWER

SK SINK

SOV LINE SIZE, FULL OPEN PORT SHUTOFF VALVE

SS SERVICE SINK

TAB TESTING, ADJUSTING, BALANCING

TMV THERMOSTATIC MIXING VALVE

TP TRAP PRIMER

TYP TYPICAL

U URINAL

U.O.N. UNLESS OTHERWISE NOTED

V VENT

VTR VENTTHROUGH ROOF

W WASTE

W/ WITH

WC WATER CLOSET

WCO WALL CLEANOUT

WHA WATER HAMMER ARRESTOR

WM WATER METER

WSFU WATER SUPPLY FIXTURE UNITS

°C DEGREES CELSIUS

°F DEGREES FAHRENHEIT

Ø DIAMETER

PLUMBING LEGEND

1. THE INTENT OF THESE DRAWINGS IS TO PROVIDE COMPLETE AND PROPERLY FUNCTIONING PLUMBING SYSTEMS. LABOR, MATERIALS, AND EQUIPMENT

REQUIRED TO COMPLETE THIS WORK MUST BE PROVIDED.

2. PLUMBING DRAWINGS ARE IN PART DIAGRAMMATIC AND INTENDED TO SHOW THE SCOPE AND GENERAL ARRANGEMENT OF THE WORK UNDER THIS CONTRACT. FOLLOW THESE DRAWINGS FOR SIZES OF THE EQUIPMENT, PIPING AND GENERAL PIPE ROUTING. DRAWINGS ARE NOT INTENDED TO BE SCALED FOR ROUGH-IN MEASUREMENTS NOR TO SERVE AS SHOP DRAWINGS. WHERE JOB CONDITIONS REQUIRE CHANGES OR ADJUSTMENTS IN THE INDICATED LOCATIONS OR ARRANGEMENT OF THE WORK, SUCH CHANGES MUST BE MADE WITHOUT CHANGE IN THE CONTRACT AMOUNT.

3. PLUMBING WORK ON THIS PROJECT MUST BE PROVIDED IN ACCORDANCE WITH THE 2021 INTERNATIONAL PLUMBING CODES AND APPLICABLE LOCAL

CODES.

4. COORDINATE PLUMBING WORK WITH SITE CONDITIONS AND THE WORK OF OTHER TRADES.

5. VERIFY SLOPES AND INVERT ELEVATIONS PRIOR TO COMMENCEMENT OF WORK.

6. THE WORK REQUIRED MUST INCLUDE PROVIDING MATERIALS, CUTTING, PATCHING, ADAPTING AND OTHER INCIDENTAL WORK, TOGETHER WITH SUCH

TEMPORARY CONNECTIONS AS MAY BE REQUIRED.

7. HORIZONTAL VENT PIPING MUST RUN ABOVE CEILING AND HORIZONTAL SANITARY PIPING MUST RUN BELOW SLAB UNLESS OTHERWISE NOTED.

8. SLOPE ALL HORIZONTAL SANITARY WASTE PIPING 2" AND SMALLER AT 1/4" PER FOOT AND SLOPE ALL HORIZONTAL SANITARY WASTE PIPING 3" AND

LARGER AT 1/8" PER FOOT UNLESS OTHERWISE SPECIFIED ON PLANS.

9. PROVIDE FIRE-STOPPING AT PENETRATIONS THROUGH RATED PARTITIONS. THIS INCLUDE PENETRATIONS THROUGH RATED WALLS, BARRIERS, CEILINGS, ROOFS, AND FLOORS. PROVIDE MANUFACTURER'S STANDARD FIRE-STOPPING SEALANT, WITH ACCESSORY MATERIALS, HAVING A MINIMUM FIRE RESISTANCE RATING EQUAL TO THE FIRE-RATED BARRIER THAT IS PENETRATED. FIRE-STOPPING SYSTEMS MUST BE UL 1479 LISTED AND TESTED

IN ACCORDANCE WITH ASTM E814.

10. PROVIDE ACCESS PANELS FOR VALVES, TRAP PRIMERS AND OTHER PLUMBING SPECIALTIES LOCATED INSIDE CHASES, BEHIND WALLS OR ABOVE

INACCESSIBLE CEILINGS.

11. SHUT OFF VALVES MUST BE PROVIDED AT THE BEGINNING OF BRANCH LINES AND AT EACH INDIVIDUAL WATER LINE SERVING WALL HYDRANTS OR HOSE BIBBS. INDIVIDUAL SHUT OFF VALVES (ANGLE STOP VALVES) MUST BE PROVIDED AT WATER SUPPLY LINES SERVING THE PLUMBING FIXTURES.

REFER TO RISER DIAGRAMS FOR LOCATIONS OF SHUT OFF VALVES.

12. DOMESTIC HOT WATER RECIRCULATION SYSTEM MUST BE PROVIDED WITH BALANCING VALVES AND CHECK VALVES AT EACH RECIRCULATION BRANCH.

13. PAINT VENT THROUGH ROOF (VTR) TO MATCH THE ADJACENT ROOF.

14. SANITARY AND STORM PIPE INVERTS EXITING THE BUILDING MUST BE COORDINATED WITH BUILDING FOOTERS.

15. FLOOR DRAINS AND FLOOR CLEANOUTS MUST HAVE SQUARE STRAINERS/TOPS IN AREAS WITH TILE FLOOR AND ROUND STRAINERS/TOPS IN OTHER

FLOOR TYPES.

GENERAL PLUMBING NOTES

NOTE:

NOT ALL ABBREVIATIONS

& SYMBOLS MAY BE USED.

PLUMBING ABBREVIATIONS

SY

M

DE

SC

RI

PT

IO

N

DA

TE

TRAINING/

CONFERENCE

E6 BUNKS

LOCKER

COFFEE / MESS

106 MECHANICAL

VESTIBULE

CORRIDOR

STORAGE

TOILETS /

SHOWER

TOILETS /

SHOWER

JAN

SIPR OIS

AWEPS OFFICE

SEA OFFICE

IDS MONITORING

OFFICE

LOCKER

E7 BUNKS

E7 BUNKS

E6 BUNKS

LACTATION

TELECOM

ELECTRICAL

ELEC

P-401 C2

P-401 A2

6" SS

4" SS

FCO-2 1

4" SS

3" SS

4" SS

WASHER/ DRYER

FCO-2

OIS OFF

ARMS ROOM

WEAPONS

OFFICER

DOWNSPOUT, TYP.

2 2 2 2 2

4" SD 4" SD 4" SD 4" SD 4" SD

3 3 3

4 4 4

A

B

C

2 3 4 6 7 85

2" SS

FFE = 124.60'

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-101

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

S

AN

IT

AR

Y

VE

NT

F

LO

O R

PL

AN

MJL

12894007

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -1

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. REFER TO ENLARGED PLANS FOR DETAILED PIPE SIZING AND FIXTURE TAG

DESIGNATIONS.

C. PROVIDE UL LISTED FIRE-STOPPING SYSTEMS AT PENETRATIONS THROUGH

RATED PARTITIONS.

1/8" = 1'-0"B1 PLUMBING SANITARY & VENT FLOOR PLAN

1 6" SANITARY TO MAIN SANITARY SEWER, EXTEND 5' FROM EXTERIOR FROM

BUILDING. REFER TO CIVIL FOR CONTINUATION. I.E.: 5'-0" BFF.

2 PROVIDE 1' x 2' CONCRETE SPLASH BLOCK TO SERVE DOWNSPOUT FROM

ABOVE.

3 DOWNSPOUT FROM ABOVE, REFER TO ARCHITECTURE. PROVIDE CAST IRON

DOWNSPOUT BOOT WITH INTEGRAL CLEANOUT PRIOR TO TRANSITION TO

STORM PIPE AND PENTRATING BELOW GRADE. REFER TO CIVIL FOR

DOWNSPOUT CONNECTION DETAIL.

4 4" STORM DRAINAGE, EXTEND 5' FROM EXTERIOR OF BUILDING. SEE CIVIL

FOR CONTINUATION. I.E.: 2'-0" BFF.

5 REFER TO STRUCTURAL FOR PIPING DETAIL BELOW FOUNDATION.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

TRAINING/

CONFERENCE

E6 BUNKS

LOCKER

COFFEE / MESS

MECHANICAL

VESTIBULE

CORRIDOR

STORAGE

TOILETS /

SHOWER

TOILETS /

SHOWER

JAN

117 SIPR OIS

AWEPS OFFICE

SEA OFFICE

IDS MONITORING

OFFICE

LOCKER

E7 BUNKS

E7 BUNKS

E6 BUNKS

LACTATION

TELECOM

ELECTRICAL

ELEC

P-402 C2

P-402 A2

3/4" DCW

2 1/2" DCW

2 1/2" DCW

NFHB-1

NFHB-1

2 1/2" DCW

WASHER/ DRYER

ARMS ROOM

WEAPONS

OFFICER

OIS OFF

S.O.V.

S.O.V.

A

B

C

2 3 4 6 7 85

3/4" DCW

1" DCW

3/4" DCW

FFE = 124.60'

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-102

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

D O

M

ES

TI

C

W

AT

ER

F

LO

O

R

PL

AN

MJL

12894008

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -1

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/8" = 1'-0"B1 PLUMBING DOMESTIC WATER FLOOR PLAN

1 2-1/2" DOMESTIC WATER SERVICE, EXTEND 5' FROM BUILDING. I.E.: 6'-1" BFF.

WATER PIPE SIZES BASED ON A MINIMUM WORKING PRESSURE OF 65 PSI AT

A FLOW RATE OF 84 GPM AT THE LOCATION WHERE THE MAIN WATER

SERVICE ENTERS THE BUILDING. REFER TO CIVIL FOR CONTINUATION.

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. REFER TO ENLARGED PLANS FOR DETAILED PIPE SIZING AND FIXTURE TAG

DESIGNATIONS.

C. PROVIDE UL LISTED FIRE-STOPPING SYSTEMS AT PENETRATIONS THROUGH

RATED PARTITIONS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

1/2

1/2

TOTAL ROOF AREA: 11,100 SF

TOTAL STORM FLOW: 320 GPM

RF-1

RF-2

RF-3

DOWNSPOUT, TYP. OF 10

MINIMUM SIZE: 2"X4"

ROOF AREA: 1,100 SF

STORM FLOW: 32 GPM

SECONDARY SCUPPER,

TYP.OF 10

MINIMUM SIZE (H x W): 4"X10"

ROOF AREA: 1,100 SF

STORM FLOW: 32 GPM

ROOF ACCESS HATCH;

REFER TO ARCHITECTURE

3" VTR

3" VTR

A

B

C

2 3 4 6 7 85

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-103

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

R O

O F

PL

AN

MJL

12894009

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -1

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1 PROVIDE RADON FAN ASSEMBLY AT ROOF. REFER TO RADON FAN

ASSEMBLY DETAIL ON SHEET P-502 FOR DETAILED PIPING AND MOUNTING

ARRANGEMENT.

1/8" = 1'-0"B1 PLUMBING ROOF PLAN

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. ROOF DRAINAGE SIZED FOR MAXIMUM RAINFALL RATE OF 2.75"/HOUR AND

TABLES 1106.2 AND 1106.3 OF THE 2021 IPC.

C. SCUPPER AND DOWNSPOUT SIZES INDICATED ARE THE MINIMUM REQUIRED

SIZES BASED ON TABLES 1106.2 AND 1106.3 OF THE 2021 IPC. REFER TO

ARCHITECTURAL DRAWINGS FOR MORE INFORMATION ON THE SCUPPERS

AND DOWNSPOUTS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

TRAINING/

CONFERENCE

E6 BUNKS

LOCKER

COFFEE / MESS

MECHANICAL

VESTIBULE

CORRIDOR

STORAGE

TOILETS /

SHOWER

TOILETS /

SHOWER

JAN

WEAPONS

OFFICER

SIPR OIS

OIS OFF

AWEPS OFFICE

SEA OFFICE

IDS MONITORING

OFFICE

LOCKER

E7 BUNKS

E7 BUNKS

E6 BUNKS

LACTATION

TELECOM

ELECTRICAL

ELEC

4" R 4" R

4" R 4" R

4" R

4" R

4" R 4" R 4" R

4" R

4" R 4" R

WASHER/ DRYER

4 4RADON

MONITOR 5

ARMS ROOM

A

B

C

2 3 4 6 7 85

4" R

4" R

FFE = 124.60'

PLAN

NORTH

1/8" = 1'-0"

24'4' 8' 16'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-104

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

R

AD

O N

M

IT

IG

AT

IO

N

FL

O

O R

PL

AN

MJL

12894010

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -1

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1 ROUTE RADON PIPING TO AVOID COLUMN FOOTER AT THIS LOCATION;

REFER TO STRUCTURAL.

2 4" RADON UP TO RADON FAN AT ROOF.

3 4" RADON UP FROM BELOW SLAB. REFER TO RADON RISER FROM SLAB

DETAIL ON SHEET P-502.

4 RADON VAPOR MONITORING POINT. REFER TO VAPOR MONITORING POINT

DETAIL ON SHEET P-502.

5 PROVIDE INDOOR RADON MONITOR CAPABLE OF AUTOMATICALLY

DISPLAYING CURRENT AND LONG TERM RADON MEASUREMENTS. MOUNT 60"

ABOVE THE FLOOR.

6 RADON SYSTEM VAPOR EXTRACTION POINT. TRANSITION TO SCHEDULE 40

SOLID WALL PVC FROM THIS POINT TO THE ROOF TERMINATION.

1/8" = 1'-0"B1 PLUMBING RADON MITIGATION FLOOR PLAN

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. BELOW GRADE RADON PIPING MUST BE PERFORATED SCHEDULE 40 PVC.

RADON PIPING FROM THE VAPOR EXTRACTION POINT BELOW GRADE TO THE

DISCHARGE POINT ON THE ROOF MUST BE SOLID SCHEDULE 40 PVC.

C. RADON PIPING INDICATED ON THIS SHEET IS ROUTED BELOW THE SLAB

UNLESS NOTED OTHERWISE.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

0' - 0"

JAN

MS-1

FD-1

DHWH-1

ET-1

DCP-1

TMV-1

TP-1

1/2" DCW

1 1/4" DCW

1 1/2" DCW

1 1/2" DHW

WHA-A

1 1/4" DCW

S.O.V. (TYPICAL,

RESTROOM BRANCHES)

3/4" DHWR

3/4" DHWR

FIRST FLOOR

0' - 0"

ROOF MEMBRANE LP

16' - 0"

MECHANICAL

2 1/2" DCW

3/4" DCW

WATER METER

BYPASS

WM-1

Y-STRAINER

RPZ-1

PRV

RADON

MONITOR TP-2

TMV-2

DHWH-2

FD-2

NFHB-1

3/4" DCW

RADON VAPOR

MONITORING POINT

2 1/2" DCW

HB-1

REMOTE WATER

METER DISPLAY

FIRE SUPPRESSION BACKFLOW PREVENTER AND RISER PIPING

IN THIS AREA; REFER TO FIRE PROTECTION DRAWINGS

ET-2

FD-2

FCO-2

FD-3

1/2" DCW

3/4" DCW

2 1/2" DCW

1/2" DHW

3/4" DCW

3/4" DHW

3/4" DHW

3/4" DCW

PLAN

NORTH

1/2" = 1'-0"

1' 2' 4' 6'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-301

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

S

EC

TI

O

NS

MJL

12894011

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -3

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/2" = 1'-0"C3 JANITOR CLOSET SECTION - WEST

1/2" = 1'-0"A1 MECHANICAL ROOM SECTION - SOUTH

1 REFER TO WATER SERVICE ENTRANCE DETAIL ON SHEET P-501 FOR RPZ

PIPING SUPPORT LOCATIONS AND DETAILED PIPING ARRANGEMENT.

2 REFER TO ELECTRIC WATER HEATER DETAIL (MECH ROOM) ON SHEET P-501

FOR DETAILED PIPING ARRANGEMENT.

3 REFER TO ELECTRIC WATER HEATER DETAIL (JANITOR CLOSET) ON SHEET

P-501 FOR DETAILED PIPING ARRANGEMENT.

4 RADON VAPOR MONITORING POINT. REFER TO VAPOR MONITORING POINT

DETAIL ON SHEET P-502.

5 PROVIDE REMOTE DISPLAY FOR WM-1 MOUNTED 60" ABOVE THE FLOOR.

6 PROVIDE INDOOR RADON MONITOR CAPABLE OF AUTOMATICALLY

DISPLAYING CURRENT AND LONG TERM RADON MEASUREMENTS. MOUNT 60"

ABOVE THE FLOOR.

7 6" HOUSEKEEPING PAD, EXTEND 6" FROM EQUIPMENT FOOTPRINT. REFER TO

STRUCTURAL DRAWINGS FOR DETAILED DIMENSIONS AND SPECIFICATIONS.

COORDINATE EQUIPMENT PAD DIMENSIONS WITH FINAL EQUIPMENT

SELECTIONS.

8 COORDINATE FLOOR DRAIN LOCATIONS WITH FOOTPRINTS OF EQUIPMENT

HOUSEKEEPING PADS. COORDINATE FLOOR DRAIN LOCATIONS ONCE FINAL

EQUIPMENT SUBMITTALS HAVE BEEN APPROVED AND HOUSEKEEPING PAD

DIMENSIONS ARE FINAL.

9 ENCASE DCW PIPING WITHIN ALUMINUM JACKETING TO PROTECT THE PIPING

FROM UNAUTHORIZED CONNECTIONS PRIOR TO BACKFLOW PREVENTER.

PROVIDE LABEL ON PROTECTIVE SLEEVE INDICATING "NO CONNECTIONS

ALLOWED" EVERY 5 FEET.

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. PROVIDE UL LISTED FIRE-STOPPING SYSTEMS AT PENETRATIONS THROUGH

RATED PARTITIONS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

COFFEE / MESS

MECHANICAL

FD-3

EWC-1

FD-2

SK-1

FCO-2

ROOF ACCESS LADDER;

REFER TO ARCHITECTURE

3" VTR

2" SS 1 1/2" V

1 1/2" V

2" V

REMOTE WATER

METER DISPLAY

RADON

MONITOR

FD-2

4" SS

6" SS

6" SS

2" SS

FD-2

4" SS

6" SS

4" SS

6" SS

4" SS

C

7 8

TOILETS /

SHOWER

TOILETS /

SHOWER

LACTATION

FD-1

FD-1

U-1

L-1L-1

L-1L-1 L-1

L-1

SH-1

SH-1 MS-1

FD-1

JAN

SK-2

OB-3 LI-1

FCO-2

(STACKED

WASHER/DRYER)

WASHER/ DRYER

FD-1

SH-2

SH-2

EWC-1

WC-1 WC-2 WC-2

WC-1 WC-2

4" SS

2" SS

3" SS

3" SS

2" SS

WCO 2" SS 1 1/2" V

2" V

1 1/2" V

WCO 2" SS

3" VTR

2" V

2" V

2" V

WCO

3" SS

3" SS

1 1/2" V

2" SS

FD-1

3" SS

4" SS

4" SS

FCO-1

FCO-2

2" SS

TYP.3

TYP.3

1 3

FD-1

3" SS

FCO-2

4" SS

4" SS

4" SS

4" SS

2" SS

B

3" SS

2" SS

WCO

3" SS

3" SS

1 1/2" V

3" SS

PLAN

NORTH

1/4" = 1'-0"

2' 4' 8' 12'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-401

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

E

NL

AR

G

ED

P

LA

NS

SA

NI

TA

RY

V

EN

T

MJL

12894012

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -4

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/4" = 1'-0" (P-101)A2 PLUMBING SANITARY & VENT ENLARGED PLAN - MECHANICAL ROOM

1/4" = 1'-0" (P-101)C2 PLUMBING SANITARY & VENT ENLARGED PLAN - RESTROOMS

1 1-1/2" V UP.

2 2" V UP.

3 2" SS DOWN THROUGH SLAB.

4 2" SS DOWN THROUGH SLAB, 1-1/2" V UP.

5 2" SS DOWN THROUGH SLAB, 2" V UP.

6 6" HOUSEKEEPING PAD, EXTEND 6" FROM EQUIPMENT FOOTPRINT. REFER TO

STRUCTURAL DRAWINGS FOR DETAILED DIMENSIONS AND SPECIFICATIONS.

COORDINATE EQUIPMENT PAD DIMENSIONS WITH FINAL EQUIPMENT

SELECTIONS.

7 COORDINATE FLOOR DRAIN LOCATIONS WITH FOOTPRINTS OF EQUIPMENT

HOUSEKEEPING PADS. COORDINATE FLOOR DRAIN LOCATIONS ONCE FINAL

EQUIPMENT SUBMITTALS HAVE BEEN APPROVED AND HOUSEKEEPING PAD

DIMENSIONS ARE FINAL.

8 2" SS DOWN THROUGH SLAB, 2" V UP (SERVING U-1).

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. PROVIDE UL LISTED FIRE-STOPPING SYSTEMS AT PENETRATIONS THROUGH

RATED PARTITIONS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

COFFEE / MESS

MECHANICAL

FD-3

Y-STRAINER

WM-1

METER BYPASS

PRV SET

TO 65 PSI

NFHB-1

1" DCW

3/4" DCW

2 1/2" DCW

EWC-1

SK-1

1/2" DCW

OB-2

OB-2

OB-1

(COFFEE

MAKER)

(WATER/ICE

MACHINE)

RPZ-1 4

(REF)

2 1/2" DCW

WHA-A

ROOF ACCESS LADDER;

REFER TO ARCHITECTURE

FD-2

ET-2

TP-2TMV-2

DHWH-2

HB-1

1/2" DHW

A1 P-301

REMOTE WATER

METER DISPLAY

RADON

MONITOR 1314

FD-2

FD-2

2 1/2" DCW

3/4" DCW

2 1/2" DCW

C

7 8

LACTATION

TOILETS /

SHOWER

TOILETS /

SHOWER

U-1

FD-1

FD-1

SH-1

SH-1

FD-1

MS-1

DHWH-1

FD-1

L-1L-1 L-1

L-1L-1

HB-1

L-1

HB-1

ET-1

2 1/2" DCW

EWC-1

NFHB-1

1 1/2" DHW

3/4" DHW

3/4" DHWR

3/4" DHW

3/4" DCW

SK-2

OB-3

WASHER/ DRYER

(STACKED

WASHER/DRYER)

SH-2

SH-2

FD-1

WHA-C

TP-1

WHA-A

WC-2 WC-2

WC-2

3/4" DCW

3/4" DCW

3/4" DHW

3/4" DCW

3/4" DHW

1" DCW

2 1/2" DCW

1 1/2" DHW

1" DCW

1" DHW

2" DCW

1" DCW

1/2" DHW

3/4" DCW

1/2" DCW

3/4" DCW

1" DCW

TP-1

TP-1

TMV-1

DCP-1

C3 P-301

WC-1

WC-1

2" DCW

1 1/2" DCW

3/4" DHWR

B

3/4" DCW

1/2" DCW

PLAN

NORTH

1/4" = 1'-0"

2' 4' 8' 12'

GENERAL SHEET NOTES

SHEET KEYNOTES

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-402

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

E

NL

AR

GE

D

PL

AN

S

-D O

M

ES

TI

C

W

AT

ER

MJL

12894013

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -4

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

1/4" = 1'-0" (P-102)A2 PLUMBING DOMESTIC WATER ENLARGED PLAN - MECHANICAL ROOM

1/4" = 1'-0" (P-102)C2 PLUMBING DOMESTIC WATER ENLARGED PLAN - RESTROOMS

1 2-1/2" DCW SERVICE UP THROUGH SLAB; PROVIDE LINE SIZE S.O.V. IN

VERTICAL.

2 REFER TO ELECTRIC WATER HEATER DETAIL (MECH ROOM) ON SHEET P-501

FOR DETAILED PIPING ARRANGEMENT.

3 REFER TO ELECTRIC WATER HEATER DETAIL (JANITOR CLOSET) ON SHEET

P-501 FOR DETAILED PIPING ARRANGEMENT.

4 REFER TO WATER SERVICE ENTRANCE DETAIL ON SHEET P-501 FOR RPZ

PIPING SUPPORT LOCATIONS AND DETAILED PIPING ARRANGEMENT.

5 ENCASE DCW PIPING WITHIN ALUMINUM JACKETING TO PROTECT THE PIPING

FROM UNAUTHORIZED CONNECTIONS PRIOR TO BACKFLOW PREVENTER.

PROVIDE LABEL ON PROTECTIVE SLEEVE INDICATING "NO CONNECTIONS

ALLOWED" EVERY 5 FEET.

6 PROVIDE INDIVIDUAL ASSE 1024 DUAL CHECK VALVE ON SUPPLY TO OB-2

FOR COFFEE MAKER.

7 PROVIDE INDIVIDUAL ASSE 1024 DUAL CHECK VALVE ON SUPPLY TO OB-2

FOR WATER/ICE MACHINE.

8 PROVIDE 8" x 8" METAL ACCESS PANEL FOR TRAP PRIMER VALVE & WATER

HAMMER ARRESTOR ACCESS.

9 PROVIDE BALANCING VALVE AND CHECK VALVE FOR RECIRCULATION

BRANCH. SET BALANCING VALVE TO 0.5 GPM. FINALIZE BALANCING VALVE

FLOW DURING TAB.

10 PROVIDE 18" X 18" WHITE POWDERCOATED ACCESS PANEL IN CEILING AT

BALANCING VALVES.

11 PROVIDE 1/2" DCW FROM TP-1 TO FLOOR DRAIN.

12 PROVIDE 1/2" DCW FROM TP-2 TO FLOOR DRAIN.

13 PROVIDE REMOTE DISPLAY FOR WM-1 MOUNTED 60" ABOVE THE FLOOR.

14 PROVIDE INDOOR RADON MONITOR CAPABLE OF AUTOMATICALLY

DISPLAYING CURRENT AND LONG TERM RADON MEASUREMENTS. MOUNT 60"

ABOVE THE FLOOR.

15 REFER TO STRUCTURAL FOR PIPING DETAIL BELOW FOUNDATION.

16 PROVIDE LINE SIZE ISOLATION VALVES ON BRANCH LINES (TYPICAL).

17 PROVIDE LINE SIZE S.O.V. IN VERTICAL.

18 6" HOUSEKEEPING PAD, EXTEND 6" FROM EQUIPMENT FOOTPRINT. REFER TO

STRUCTURAL DRAWINGS FOR DETAILED DIMENSIONS AND SPECIFICATIONS.

COORDINATE EQUIPMENT PAD DIMENSIONS WITH FINAL EQUIPMENT

SELECTIONS.

A. REFER TO SHEET P-001 FOR LEGEND AND GENERAL NOTES.

B. PROVIDE UL LISTED FIRE-STOPPING SYSTEMS AT PENETRATIONS THROUGH

RATED PARTITIONS.

SY

M

DE

SC

RI

PT

IO

N

DA

TE

N.O.

N.O.

N.O.

P.G.

2-1/2" DOMESTIC

WATER SUPPLY

2-1/2" DCW

P.G.

WATER SUPPLY

DISTRIBUTION

FINISHED FLOOR

REDUCED PRESSURE ZONE BACKFLOW

PREVENTER ASSEMBLY

PIPE RELIEF TO FLOOR

DRAIN IN MECHANICAL

ROOM, PROVIDE AIR GAP 2-1/2" DCW

N.C.

PRESSURE

REGULATOR:

SET TO 65 PSI

P.G.

PRE-MANUFACTURED

PIPE SUPPORT - TYPICAL

WATER METER BYPASS

S.O.V. - BALL

VALVE (TYP)

N.O.

N.O.

3/4" THREADED HOSE

END WITH CAP

Y-STRAINER

ADVANCED METERING

WATER METER WITH

INTEGRAL STRAINER

RPZ ASSEMBLY MUST HAVE AT LEAST 12" CLEAR TO THE WALL BEHIND

THE ASSEMBLY AND 36" CLEAR IN FRONT OF THE ASSEMBLY; MAINTAIN

ALL INSTALLATION CLEARANCES AS REQUIRED BY THE MANUFACTURER

N.O.

WALL MOUNTED REMOTE READOUT DEVICE

2-1/2" DCW

SLEEVE AND SEAL

2" DCW

LOCKABLE BALL VALVE

NORMALLY CLOSED

REFER TO STRUCTURAL FOR PIPING

DETAIL BELOW FOUNDATION

DCP-1

DRAIN VALVE - TYPICAL

T&P RELIEF VALVE -

TYPICAL

FINISHED FLOOR

1-1/2" DHW (131°F) TO

PLUMBING FIXTURES

NOTE: FULL-SIZE

DISCHARGE THROUGH

AN AIR GAP TO THE

FLOOR DRAIN.

DHWH-1

1-1/4" DHW (131°)

1-1/4" DHW (140°)

1-1/4" DCW

1-1/2" DCW

1-1/4" DCW

EXPANSION TANK, ET-1

THERMOSTATIC

MIXING VALVE, TMV-1

THERMOMETER (TYP.)

LOCKABLE ISOLATION

VALVE LOCKED IN

THE OPEN POSITION

DCW SUPPLY LINE

TO DOMESTIC HOT

WATER HEATER

6" CONCRETE

HOUSEKEEPING PAD

P.G. (TYP.)

3/4" DHWR (122°) FROM

PLUMBING FIXTURES

3/4" DHWR

3/4" DHWR

BALANCING VALVE, TYPICAL

CONTROL WIRING

TEMPERATURE PROBE

3/4" DHWR

TIMER & AQUASTAT CONTROL; PROVIDE IMMERSION TYPE AQUASTAT,

ON AT 122°F, OFF AT 128°F (ADJ.), SET ON SO THAT PUMP WILL

ENERGIZE, BASED ON AQUASTAT READING, BETWEEN 0500-1700.

HEAT TRAP

FITTING

LINE SIZE SHUT OFF

VALVE, TYPICAL

3/4" DHWR

1-1/4" DCW

1-1/4" DHW

1-1/4" DCW

VACUUM RELIEF

VALVE

FLOW

CONCRETE SURFACE OR FLOOR

COVERING AS REQUIRED

CLEANOUT COVER

COUNTERSUNK SCREW

CLEANOUT PLUG

FINISHED FLOOR

CAULKING FERRULE

NOTE: TOP OF CLEANOUT

FLUSH WITH FINISHED FLOOR.

CAST-IRON

CLEANOUT TEE

FLOW

WASTE LINE

MAY EXTEND AS

WASTE OR VENT

WASTE LINE 1/8TH BEND

ACCESS COVER

COUNTERSUNK

SCREW

CLEANOUT PLUGNO-HUB COUPLING

SLEEVE THRU SLAB

SEAL WATERTIGHT

FLOOR DRAIN

FLOOR SLAB

1/2" TRAP PRIMER LINE

1/2" TRAP PRIMER SUPPLY

DOMESTIC WATER LINE

BALL VALVE

CONNECT TO TOP OF DOMESTIC

WATER BRANCH LINE

TRAP PRIMER VALVE. PROVIDE WITH

DISTRIBUTION UNIT TO SERVE

MULTIPLE FLOOR DRAINS

PROVIDE TYPE "K" SOFT COPPER PIPING IN 1/2"

ARMAFLEX INSULATION. ENCASE COPPER PIPING

IN PLASTIC SLEEVE BELOW FLOOR SLAB ONLY

ACCESS DOOR

SLEEVE THRU SLAB

SEAL WATERTIGHT

FLOOR DRAIN

FLOOR SLAB

PROVIDE TYPE "K" SOFT COPPER PIPING IN 1/2"

ARMAFLEX INSULATION. ENCASE COPPER PIPING

IN PLASTIC SLEEVE BELOW FLOOR SLAB ONLY

ATMOSPHERIC

VACUUM BREAKER

3/4" DISTRIBUTION

MANIFOLD1/2" TRAP PRIMER

LINE, TYPICAL

3/4" DCW

BRANCH LINE

BALL VALVE

SOLENOID VALVE

120V POWER CONNECTION,

REFER TO ELECTRICAL DRAWINGSMANUAL OVERRIDE

SWITCH/TEST

CONTROL PANEL

DRAIN VALVE - TYPICAL

T&P RELIEF VALVE -

TYPICAL

FINISHED FLOOR

3/4" DHW (131°F) TO

PLUMBING FIXTURES

NOTE: FULL-SIZE

DISCHARGE THROUGH

AN AIR GAP TO THE

MOP SINK

DHWH-2

3/4" DHW (131°)

3/4" DHW (140°)

3/4" DCW

3/4" DCW

3/4" DCW

EXPANSION TANK, ET-2

THERMOSTATIC

MIXING VALVE, TMV-2

THERMOMETER (TYP.)

LOCKABLE ISOLATION

VALVE LOCKED IN

THE OPEN POSITION

DOMESTIC COLD WATER SUPPLY LINE

TO DOMESTIC HOT WATER HEATER

PROVIDE STEEL WATER

HEATER STAND IN MECH

ROOM

P.G. (TYP.)

HEAT TRAP

FITTING

LINE SIZE SHUT OFF

VALVE, TYPICAL

3/4" DCW

3/4" DHW

3/4" DCW

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P

AR

TM

E

N T

O F

TH

E

N A

VY

N

A

VA

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S

YS

TE

M

S C

O M

M A

N D

PM/DM

BRANCH MANAGER

CHIEF ENG/ARCH

FIRE PROTECTION

AS NOTED

1100 NORTH GLEBE ROAD

SUITE 500

ARLINGTON, VIRGINIA 22201

571.218.1000

FAX: 571.218.1600

6/

/2

:1 3:

P

M \\d c1 vs

\F

ED

PR

J\

FD

ZE

\P

LU

M

\B

LD

G -1

-P

-B

IM

_v

.rv t

P-501

P-

W

EA

PO

NS

M

AG

AZ

IN

E

OR

DN

AN

CE

O

PE

RA

TIO

NS

F

AC

ILI

TY

PL

UM

BI

NG

D

ET

AI

LS

MJL

12894014

CWH BPT

05/27/2025

APPROVED BY LCDR ELIZABETH

OLOKODE NAVFAC NLON FEAD

DIRECTOR NEW LONDON, GROTEN, CT

O

PE

RA

TI

O

NS

SMS/CWJ

1667770

GR

OT

ON

, C

ON

NE

CT

IC

UT

NA

VA

L S

UB

MA

RI

NE

B

AS

E

NE

W

LO

ND

ON

JWJ

ALG

HPN

M

ID

-A

TL

A N

TI

C

P -5

NA

VA

L

FA

CI

LI

TI

ES

E

NG

IN

EE

RI

NG

S

YS

TE

M

S

CO

M M

AN

D

-M

ID

-A

TL

AN

TI

C N

A

VA

L S

TA

TI

O N

N

O R

FO

LK

, V A

NTSC3 WATER SERVICE ENTRANCE DETAIL

NTSA4 ELECTRIC WATER HEATER DETAIL (JANITOR CLOSET)

NTSD2 FLOOR CLEANOUT DETAIL

NTSD1 WALL CLEANOUT DETAIL

NTSA1 TRAP PRIMER DETAIL

NTSA2 ELECTRONIC TRAP PRIMER DETAIL

NTSB1 ELECTRIC WATER HEATER DETAIL (MECHANICAL ROOM)

SY

M

DE

SC

RI

PT

IO

N

DA

TE

CAPPED PIPE TERMINATION

SUBGRADE

4" PERFORATED SCHEDULE 40 PVC

VAPOR COLLECTION LAYER

4" MINIMUM

4" MINIMUM

COORDINATE RADON PIPING

INSTALLATION WITH STRUCTURAL

RODENT SCREEN WITH

1/2" OPENINGS

VERTICAL EXHAUST MUST EXTEND 24"

MINIMUM ABOVE FLAT ROOF AND 20' MINIMUM

HORIZONTALLY FROM ALL BUILDING

OPENINGS AND EQUIPMENT AIR INTAKES.

4" PVC WYE FITTING

45 DEGREE ELBOW

RISER SECURED TO UNISTRUT

FRAME OR STRUCTURE 3" BELOW

FLEXIBLE COUPLING4" PVC RISER THROUGH ROOF,

PENETRATION SEALED AND

INSULATED PER ROOFING

SPECIFICATIONS

1" ID TUBING WITH

1/2" INSULATION

INLINE FAN INSTALLED 12"

MINIMUM ABOVE FLAT ROOF

1" ID BARB FITTING

PVC CAP FITTING

RISER WYE SECURED TO

UNISTRUT FRAME OR STRUCTURE

FLEXIBLE RUBBER COUPLING

RADON FAN SECURED

TO UNISTRUT FRAME

FLEXIBLE RUBBER COUPLING

RADON MITIGATION RISER PIPE SLAB

PENETRATION, SOLID 4" SCHEDULE 40 PVC

CABLE TIE

SLAB

REINFORCEMENT FABRIC

VAPOR BARRIER TOP LAYER

VAPOR COLLECTION LAYER

BELOW SLAB RADON COLLECTION PIPE,

PERFORATED 4" SCHEDULE 40 PVC

4" MINIMUM

4" MINIMUM

SUBGRADE

COORDINATE RADON PIPING

INSTALLATION WITH STRUCTURAL

SUBGRADE

SYSTEM LOW POINT

4" PERFORATED SCHEDULE 40 PVC

SOLID RISER PIPE TRANSITION FROM

PERFORATED RADON COLLECTION PIPE

4" SOLID SCHEDULE 40 PVC RISER PIPE TO EXHAUST POINT,

MINIMUM 1/8"/FT SLOPE TOWARDS SYSTEM LOW POINT

VAPOR COLLECTION LAYER

COORDINATE RADON PIPING

INSTALLATION WITH STRUCTURAL

1/4" NPT HOLLOW HEX PLUG

FLOOR CLEANOUT, FLUSH

MOUNT WITH FLOOR

STAINLESS STEEL 1/4" NPT FEMALE CONNECTOR

WITH 1/4" TUBE OD NPT CONNECTION

SELF LEVELING POLYURETHANE SEALANT/CAULK MINIMUM

3/8" THICK, SEAL MONITORING POINT ASSEMBLY AIR TIGHT

STAINLESS STEEL FLAT WASHER

1/2" ID X 1" OD X 1/8" THICK

BETWEEN FEMALE COONECTOR

AND COMPRESSION NUT

STAINLESS STEEL POST

CONNECTOR TUBE FITTING,

1/4" TUBE OD

1/4" ID HDPE PLASTIC TUBING

ON POST CONNECTOR

NON-SHRINK GROUT, 4" DEPTH MINIMUM VAPOR BARRIER

ENLARGED VIEW

FLOOR SLAB

2" MIN.

SUBGRADE

VAPOR COLLECTION LAYER

VAPOR BARRIER

VAPOR MONITORING POINT ASSEMBLY

FLOOR SLAB

24" MINIMUM

NON-SHRINK GROUT,

4" DEPTH MINIMUM

FLOOR CLEANOUT, FLUSH

MOUNT WITH FLOOR

BACKER ROD AND PEA GRAVEL TO

LOOSELY FILL VOID BENEATHE

CLEANOUT TO PERMIT GROUTING,

ENSURE HDPE TUBING REMAINS

OPEN AND PERMITS FREE

FLOWING AIR

2" DIAMETER STAINLESS STEEL

PIPE WITH TEE FITTING, OPEN ON

BOTH ENDS BENEATHE SLAB

1/4" ID HDPE PLASTIC TUBING

CONNECTED TO MONITORING

ASSEMBLY, OPEN TO SUB-SLAB

ENVIRONMENT WITHIN STEEL PIPE

2" MIN.

COORDINATE RADON PIPING INSTALLATION WITH STRUCTURAL

MAGNEHELIC DIFFERENTIAL

PRESSURE GAUGE MOUNTED

ON WALL

4" MINIMUM

4" MINIMUM

BRANCH PIPE FROM

SUB-SLAB MITIGATION

SLAB PENETRATION PER

RADON MITIGATION RISER

PIPE THROUGH SLAB DETAIL

PVC BALL VALVE

RISER TO EXHAUST LOCATION

ON ROOF, 4" SCHEDULE 40 PVC

PIPE MOUNTED

AIRFLOW ALARM

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONS…