AD101.pdf
PDF 449 KB Posted
- Solicitation number
- N4008525R2522
About this file
This document is a demolition plan and photographic documentation for Building 986 at Marine Corps Air Station (MCAS) Beaufort in Norfolk, Virginia, part of the P-502 Replace Fuel Pier project. The detailed plan includes comprehensive demolition instructions for a single-story, pre-engineered metal frame building, specifying complete removal of the existing structure, hoist, concrete curb, and slab. Critical notes highlight hazardous material considerations, including the presence of lead-based paint, cadmium/chromium containing paint, and mercury-containing sources, with specific references to handling and disposal procedures outlined in the project specifications. The demolition plan is part of Naval Facilities Engineering Systems Command (NAVFAC) Mid-Atlantic project, with contract number N40085-18-D-0600, and was approved on 09/05/2024 by project managers from MCAS Beaufort and DLA Energy.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
B
STORAGE
+/- 38' - 4"
AD101
C2
AD101
C3
AD101
B3
AD101
C1
1. DEMOLISH EXISTING BUILDING INCLUDING STRUCTURE AND
COMPONENTS COMPLETELY. DEMOLISH EXISTING HOIST.
2. DEMOLISH CONCRETE CURB AND SLAB AS PART OF PIER DECK
DEMOLITION. REFER TO STRUCTURAL PIER DEMOLITION DRAWINGS.
3. REFER TO SD100 FOR DEMOLITION PHASING.
4. DEMOLISHED MATERIALS MUST BE LEGALLY DISPOSED OF PROMPTLY.
DO NOT ALLOW DEMOLISHED MATERIALS TO ACCUMULATE ON SITE.
NO BURNING IS ALLOWED.
5. DIMENSIONS SHOWN ARE APPROXIMATE.
6. TYPICAL CONSTRUCTION OF B986 CONSISTS OF THE FOLLOWING:
SINGLE STORY, PRE-ENGINEERED METAL FRAME BUILDING; 10" H
CONCRETE CURB AROUND PERIMETER; NON-INSULATED METAL PANEL
WALLS OVER PEMB GIRT FRAMING; NON-INSULATED METAL ROOF
PANELS OVER PEMB PURLIN FRAMING.
7. B986 WAS TESTED FOR HAZARDOUS MATERIALS. LEAD-BASED PAINT,
CADMIUM/CHROMIUM CONTAINING PAINT, AND MERCURY CONTAINING
SOURCES WERE IDENTIFIED. REFER TO DRAWING H-101 AND THE
HAZARDOUS BUILDING MATERIALS ASSESSMENT REPORT IN THE
SPECIFICATIONS. REFER TO DIVISION 2 SPECIFICATIONS FOR
TRANSPORTATION, DISPOSAL, REMEDIATION, AND HANDLING
PROCEDURES FOR HAZARDOUS MATERIALS.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
TE
M
S C
O M
M A
N D
M
ID
-A
TL
A
N T
IC
N
A V
A L
S T
A T
IO
N
N O
R F
O L
K
N O
R F
O L
K V
A
AS NOTED
B E
A U
F O
R T
S
C
M
ID
L A
N T
D C
B L
M C
A S
B E
A U
F O
R T
P -5
R E
P L A
C E
F U
E L P
IE
R
1731481
N40085-18-D-0600
CGM / ELT
EJA
HPN
09/05/2024
APPROVED BY JEREMY B. GATES P.E.,
MCAS BEAUFORT PWO AND BRYAN GRAPPE
P.E., PROJECT MANAGER, DLA ENERGY
AD101
B U
IL
D
IN
G
D
E M
O
LI
TI
O
N P
LA
N
P
H O
TO
S
EV
12901917
LES SF
CGM
1/8" = 1'-0" A1
BUILDING 986 - DEMOLITION - FLOOR PLAN
PLAN
NORTH
NOT TO SCALE
C1
EXTERIOR 1
NOT TO SCALE
C3
INTERIOR 1
NOT TO SCALE
C2
EXTERIOR 2
NOT TO SCALE
B3
INTERIOR 2
1/8" = 1' - 0" 0 5' 10' 15' 30'
SHEET NOTES
GRAPHIC SCALE(S)
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
IS
S U
E D
F O
R C
O N
S T
R U
C T
IO
N
/0
/2
LE
S
SEAL
CGM / ELTCJC / ELT
File details come from the government source that posted it. Updated .