The file's text, extracted by GovTribe without its formatting.
N3220520R6500
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION C - DESCRIPTIONS AND SPECIFICATIONS
The following have been modified:
C – 2 List of Standard WIs included for this solicitation:
USNS MERCY
(T-AH 19)
N3220520R6500
WORK ITEM INDEX REPORT
| Item Number |
| Title |
| Category |
| SECTION 0000 |
| GENERAL SERVICES AND REQUIREMENTS |
| 0001 |
| SCOPE GEN REQUIREMENTS DEFINITIONS REV JUL 18 |
| N |
| 0002 |
| TECHNICAL AND MANUFACTURER REPRESENTATIVES REV MAY |
| N |
| 0003 |
| APPROACH BERTH AND MOORING REQUIREMENTS REV JAN 19 |
| N |
| 0004 |
| TESTING AND QUALITY ASSURANCE REV 08 NOV 17 |
| N |
| 0005 |
| ELECTRICAL SAFETY PROCEDURE REQUIREMENTS REV FEB 1 |
| N |
| 0006 |
| HEAVY WEATHER PLAN REV FEB 14 |
| N |
| 0007 |
| COLD WEATHER PLAN REV FEB 14 |
| N |
| 0010 |
| FURNISH OFFICE FOR OVERHAUL MANAGEMENT TEAM OMT RE |
| A |
| 0011 |
| FURNISH GENERAL SERVICES T AH REV FEB 14 |
| A |
| 0012 |
| INFORMATION TECHNOLOGY SERVICES REV JUL 18 |
| A |
| 0013 |
| PROJECT PLANNING AND PRODUCTION STATUS MONITORING |
| A |
| 0014 |
| WEIGHT AND MOMENT REPORT |
| A |
| 0015 |
| INTEGRATED LOGISITIC AND GFM SUPPORT REQUIREMENTS |
| A |
| 0016 |
| FIRE PROTECTION AND SHIPS SAFETY PROGRAM REV 28 SE |
| A |
| 0017 |
| HANDLING SHIPS STORES REV FEB 14 |
| A |
| 0018 |
| DELIVERY AND REDELIVERY OF THE VESSEL REV MAY 16 |
| A |
| 0019 |
| SHIPBOARD ACCESS AND SECURITY REV AUG 15 |
| A |
| 0020 |
| GAS FREE CERTIFICATES REV FEB 14 |
| A |
| 0021 |
| CLEAN AND GAS FREE TANKS VOIDS AND COFFERDAMS AND |
| A |
| 0022 |
| MACHINERY SPACE TURN-OVER DOCK TRIALS AND SEA TRIA |
| A |
| 0023 |
| HAZARDOUS WASTE DISPOSAL AT A CONTRACTORS FACILITY |
| A |
| 0024 |
| PHYSICAL SECURITY AT PRIVATE CONTRACTOR'S FACILITY |
| N |
| 0025 |
| ENHANCED PHYSICAL SECURITY AT A PRIVATE CONTRACTOR |
| B |
| 0030 |
| CONTINUATION OF SERVICE REV OCT 18 |
| B |
| SECTION 0100 |
| HULL AND STRUCTURAL |
| 0101 |
| MISCELLANEOUS TANK VENT PIPING REPAIRS |
| A |
| 0102 |
| ANTI-ROLL TANK VENT REPAIRS |
| A |
| 0103 |
| 1F BALLAST AND ANTIROLL TANK LADDER RAIL REPAIRS |
| A |
| 0104 |
| 2DB TANK SAND HOLE REPAIRS |
| A |
| 0105 |
| WATERTIGHT CLOSURE RENEWAL |
| A |
| 0106 |
| BOILER DECK REPAIRS |
| A |
| 0107 |
| WATERTIGHT DOUBLE DOOR REPLACEMENT |
| A |
| 0108 |
| RADIO ANNTENA CABLE PENETRATION REPAIR VR19-0162 |
| A |
| 0109 |
| SERVICE AREA 2 STEEL REPAIRS |
| A |
| 0110 |
| SERVICE AREA 3 DECKING REPAIRS (VR18-0127) |
| A |
| 0111 |
| SERVICE AREA 5 STEEL REPAIRS REV A |
| A |
| 0112 |
| AFT OILY WASTE TANK PRESERVATION |
| A |
| 0113 |
| RESERVE FEED TANK PRESERVATION |
| A |
| 0114 |
| SEWAGE AND EFFLUENT TANK PRESERVATION |
| A |
| 0115 |
| ENGINEROOM DOUBLE BOTTOM TANK 7-87-0 PRESERVATION |
| A |
| 0116 |
| MISSION RAMP DECK PRESERVATION STBD FR 33-42 |
| A |
| 0117 |
| JP-5 FUEL TEST LAB AND MISSION RAMP (MTF) |
| A |
| 0151 |
| ULTRASONIC THICKNESS GAUGING (5YR) |
| A |
| 0154 |
| SPECIAL SURVEY-TANK INSPECTIONS (5YR) |
| A |
| 0157 |
| POTABLE WATER TANK PRESERVATION |
| A |
| 0162 |
| WATERTIGHT CLOSURE INSPECTION |
| A |
| 0183 |
| TANK VENTS-OPEN AND INSPECT TAH 5 YR ABS |
| A |
| 0197 |
| LEAD PAINT-TESTING AND ABATEMENT |
| B |
| 0199 |
| MISC STEEL RENEWAL |
| B |
| SECTION 0200 |
| PROPULSION MACHINERY |
| 0201 |
| ESLP-MAIN STEAM PIPING REPAIR |
| A |
| 0202 |
| ESLP-AUXILIARY STEAM PIPING REPAIR |
| A |
| 0203 |
| ENGINE ORDER TELEGRAPH AND SHAFT TACHOMETER REFURB |
| A |
| 0204 |
| MAIN CONDENSER FLEX JOINTS REPLACEMENT |
| A |
| 0205 |
| MAIN CIRCULATING PUMP REPLACEMENT AND MOTOR REFURB |
| A |
| 0206 |
| STEAM VALVE OVERHAUL VR18-148 |
| A |
| 0207 |
| ESLP-BOILER INSPECTIONS |
| A |
| 0252 |
| MAIN REDUCTION GEAR INSPECTION (5YR) |
| A |
| 0254 |
| THRUST AND LINE SHAFT BEARING INSPECTION (5YR) |
| A |
| 0281 |
| BOILER INSPECTION AND HYDRO (2.5YR) |
| A |
| 0282 |
| BOILER MOUNTS OPEN INSPECT AND TEST (2.5YR) |
| A |
| 0283 |
| BOILER SAFETY VALVES OPEN INSPECT AND TEST (2.5YR) |
| A |
| 0284 |
| STEAM PIPE INSPECTION AND HYDROSTATIC TESTING (5YR |
| A |
| 0286 |
| HP AND LP STEAM TURBINE OPEN AND INSPECT (5YR) |
| A |
| 0287 |
| AUTOMATION AND PROPULSION CONTROL INSPECT AND TEST |
| A |
| 0288 |
| MAIN CONDENSER INSPECTION (5YR) |
| A |
| 0290 |
| LUBE OIL FLUSHING OF MAIN ENGINE AND RED GEAR-TAH |
| A |
| 0292 |
| MAIN FEED PUMP OVERHAUL |
| A |
| 0301 |
| ENCON-HEAT BALANCE INSTRUMENTATION INSTALL |
| A |
| 0302 |
| SSDG LOW VOLTAGE ALARM INSTALLATION |
| A |
| 0303 |
| MOTOR CONTROLLER CLEAN AND SERVICE |
| A |
| 0351 |
| SWITCHBOARD CLEANING (2.5 YR) |
| A |
| 0352 |
| MOTOR CONTROL CENTER CLEANING (2.5YR) |
| A |
| 0354 |
| GENERATOR CLEANING AND INSPECTION |
| A |
| 0399 |
| MISCELLANEOUS MOTOR OVERHAULS |
| B |
| SECTION 0400 |
| COMMUNICATION AND NAVIGATION |
| 0401 |
| HF ANTENNA COAX CABLE REPAIRS |
| A |
| 0451 |
| ANNUAL RADAR SERVICE (1YR) |
| A |
| 0452 |
| ANNUAL ECDIS SERVICE (1YR) |
| A |
| 0453 |
| ANNUAL GYRO SERVICE (1YR) |
| A |
| 0455 |
| ANNUAL RADIO COMMUNICATIONS EQUIPMENT RECERT |
| A |
| 0456 |
| MAGNETIC COMPASS SERVICE (2YR) |
| A |
| 0458 |
| WHIP ANTENNA MAINTENANCE |
| A |
| 0459 |
| ECHO SOUNDER SERVICE |
| A |
| 0460 |
| ANNUAL INSPECTION OF ALARMS (1YR) |
| A |
| 0490 |
| SPEED LOG SERVICING (5YR) |
| A |
| 0491 |
| ANNUAL SVDR RECERTIFICATION (1YR) |
| A |
| SECTION 0500 |
| AUXILIARY MACHINERY |
| 0501 |
| ESLP-TLI SENSOR INSTALLATION PHASE 2 |
| A |
| 0502 |
| ESLP-TLI SENSOR INSTALLATION PHASE 3 |
| A |
| 0503 |
| ESLP-PLUMBING SYSTEM PHASE 2 |
| A |
| 0504 |
| ESLP-PLUMBING SYSTEM PHASE 3 |
| A |
| 0505 |
| ESLP-PLUMBING SYSTEM PHASE 4 |
| A |
| 0506 |
| ESLP-SW FLUSHING STATION 1 AND 2 ADDL WORK |
| A |
| 0507 |
| ESLP-SW FLUSHING STATION 3 AND 4 OVERHAUL |
| A |
| 0508 |
| ESLP-SW FLUSHING STATION OVERHAUL 5 6 AND 7 |
| A |
| 0510 |
| MISCELLANEOUS PIPING REPAIRS |
| A |
| 0511 |
| EDG COOLING FAN AND MOTOR REPAIRS |
| A |
| 0512 |
| EDG RADIATOR REPAIRS |
| A |
| 0513 |
| BALLAST AND SEAWATER SYSTEM VALVE REPAIRS |
| A |
| 0514 |
| BALLAST SYSTEM VALVE MOTOR OPERATOR REPAIRS |
| A |
| 0515 |
| FIRE MAIN SYSTEM VALVE REPAIRS |
| A |
| 0516 |
| SEWAGE PUMP AND MOTOR OVERHAUL |
| A |
| 0517 |
| ESLP-SHIPS SERVICE DIESEL GENERATOR ENGINE OVERHAU |
| A |
| 0518 |
| ESLP-SSTG OVERHAUL |
| A |
| 0519 |
| CENTRAL FRESH WATER COOLING HEAT EXCHANGER REFURBI |
| A |
| 0520 |
| WATER MIST FIREFIGHTING SYSTEMS- 1YR TAH |
| A |
| 0552 |
| HOSE REPLACEMENT (5YR) |
| A |
| 0553 |
| PRESSURE VESSEL INSPECTION (5YR) |
| A |
| 0555 |
| INSPECT AND CERTIFY MACHINERY SPACE CRANES AND HOI |
| A |
| 0562 |
| SCBA ANNUAL INSPECTION |
| A |
| 0563 |
| SCBA AIR COMPRESSOR AND FILL STATION INSPECTION |
| A |
| 0565 |
| FIXED GAS FIREFIGHTING SYSTEM INSPECTION AND TEST |
| A |
| 0567 |
| FIXED FOAM FIREFIGHTING SYSTEMS INSPECTION (1YR) |
| A |
| 0569 |
| FIRE AND SMOKE DETECTION SYSTEM (1YR) |
| A |
| 0570 |
| PORTABLE FIRE EXTINGUISHER SERVICE (1YR) |
| A |
| 0571 |
| ANNUAL FIRE AND SMOKE DAMPER SERVICE (1YR) |
| A |
| 0572 |
| DEEP FAT FRYER AND RANGE FIRE EXT SYSTEM (1YR) |
| A |
| 0574 |
| FIRE DOORS AND SHUTTERS (1YR) |
| A |
| 0597 |
| ESLP-PLUMBING DRAIN PIPING REPLACEMENT |
| B |
| 0598 |
| SEWAGE SYSTEM 3-WAY VALVE REFURBISHMENT |
| B |
| 0599 |
| MISCELLANEOUS PIPING RENEWAL |
| B |
| SECTION 0600 |
| HABITABILITY OUTFITTING AND FURNISHINGS |
| 0601 |
| TENDER BOAT DAVIT SERVICE-ANNUAL TAH |
| A |
| 0602 |
| TENDER BOAT SERVICE-ANNUAL TAH |
| A |
| 0603 |
| RESCUE BOAT DAVIT REPAIRS |
| A |
| 0604 |
| DECK CRANE INSPECTION-5YR (NON-ABS) |
| A |
| 0605 |
| LIFE RAFT DAVIT SERVICE-ANNUAL TAH |
| A |
| 0606 |
| ELEVATOR AND DUMBWAITER GROOMING AND INSPECTION |
| A |
| 0650 |
| ESLP-LIFEBOAT REPLACEMENT |
| A |
| 0653 |
| ANNUAL RESCUE BOAT AND DAVIT INSPECTION |
| A |
| 0658 |
| ACCOMMODATION LADDER MAINTENANCE AND TESTING (5YR) |
| A |
| 0659 |
| PILOT BOARDING AND EMBARKATION LADDERS (5YR) |
| A |
| 0662 |
| DEEP FAT FRYER INSPECTION (1YR) |
| A |
| SECTION 0700 |
| SPONSOR RELATED |
| 0701 |
| O2N2 SYSTEM INSPECTION AND GROOM-2 YR |
| A |
| 0702 |
| O2N2 LPAC COMPRESSOR INSPECT AND GROOM-ANNUAL |
| A |
| 0703 |
| MTF BERTHING SHOWER PRESERVATION |
| A |
| 0704 |
| MASTER CLOCK SYSTEM INSTALLATION |
| A |
| 0705 |
| PATIENT LITTER HOIST INSPECTION-2.5 YR TAH |
| A |
| 0706 |
| OR ROOM DECK REFURBISHMENT (VR19-0213) |
| A |
| 0707 |
| OR SURROUNDING AREA DECK REFURBISHMENT (VR19-0214) |
| A |
| 0708 |
| OR COMMON CORE DECK DRAIN REPAIR(VR19-0215) |
| A |
| 0709 |
| DRY PROVISIONS ROOM MODS |
| A |
| 0802 |
| NO1 AC CONDENSER RETUBE |
| A |
| 0803 |
| AC CONDENSER END BELL REFURBISHMENT |
| A |
| 0804 |
| HALON ROOM INSULATION INSTALLATION |
| A |
| 0851 |
| ANNUAL GALLEY VENTILATION AND GAYLORD HOOD CLEANIN |
| A |
| 0852 |
| ANNUAL LAUNDRY VENT CLEANING (1YR) |
| A |
| 0899 |
| INSULATION AND LAGGING REPAIR |
| B |
| 0901 |
| DOCKING AND UNDOCKING |
| A |
| 0902 |
| TAIL SHAFT INSPECTION (ABS-IN PLACE) |
| A |
| 0903 |
| TAILSHAFT INSPECTION ABS 15 YR-REMOVAL |
| B |
| 0904 |
| PROPELLER INSPECTION AND POLISHING-TAH |
| A |
| 0905 |
| ANCHORS AND CHAINS INSPECT AND PRESERVE |
| A |
| 0906 |
| CHAIN LOCKERS INSPECT AND PRESERVE-TAH |
| A |
| 0907 |
| FREEBOARD SPOT PRESERVATION-TAH |
| A |
| 0908 |
| SSDG SEA SUCTION PIPE REPLACEMENT |
| A |
| 0909 |
| CATHODIC PROTECTION SYSTEM INSPECTION TAH |
| A |
| 0910 |
| SEA VALVES TAH 5 YR ABS-USCG |
| A |
| 0911 |
| RUDDER AND STERN FRAME EXAM TAH ABS |
| A |
| 0912 |
| SHAFT SEAL INSPECTION AND REPLACEMENT |
| A |
| 0913 |
| AUXILIARY SEAWATER PIPING CLEANING |
| A |
| 0914 |
| BILGE KEEL INSPECTION AND TESTING |
| A |
| 0915 |
| CHAIN LOCKER AND FOREPEAK EDUCTOR VALVE SERVICE |
| A |
| 0960 |
| CCSI_UNDERWATER HULL CLEANING PAINTING - SPOT BLA |
| A |
| 0966 |
| SHAFT ALIGNEMENT AND BEARING REACTION CHECKS (2.5Y |
| A |
| 0967 |
| SHAFT ALIGNMENT AND BEARING REACTION CHECKS (SETS |
| B |
| 0968 |
| SHAFT ALIGNMENT AND BEARING REACTION CHECKS (POST |
| B |
| 0984 |
| UW HULL ZINC ANODE REPLACEMENT |
| A |
| 0999 |
| EXTENSION ON DRY DOCK |
| B |
| SECTION 1000 |
| UNDERWAY REPLENISHMENT EQUIPMENT |
| 1001 |
| ESLP- V-22 FLIGHT DECK MODIFICATIONS |
| A |
(End of Summary of Changes) image1.wmf