This is a laboratory report documenting bulk sample asbestos evaluation analysis conducted by TEM Environmental, Inc. for Fermi Lab. The analysis was performed using the Polarized Light Microscopy (PLM) method following USEPA Method 600/R-93/116 (July 1993). The samples were analyzed on 5/9/2023 by Lori Boersma, with results submitted under TEM Project 69570 and NVLAP Lab Code 101130-0.

Ten roof samples were collected from various locations at Fermi Lab's Kirk & Wilson Road facility in Batavia, Illinois, including roofing materials from multiple laboratory buildings and related structures (Lab F, MINOS, F38FC, and NWA). Of the ten samples analyzed, one sample (Lab ID 481574 from Fan Hatch Roofing - Lab F) tested positive for asbestos, specifically containing 5-10% Chrysotile fibers with 90-95% filler binder composition. The remaining nine samples showed no detected asbestos. Non-asbestos materials identified across samples included glass fibers (ranging 3-30%), cellulose (15-25%), and synthetic materials (5-10%). The report notes that samples containing less than 10% asbestos may warrant additional point count method analysis to confirm regulatory classification, and samples potentially containing very small fibers may require transmission electron microscopy (TEM) testing for conclusive results. The Chain of Custody form indicates all samples were received on 5/4/2023 with a turnaround time of 6 hours, and analysis was completed with full documentation and approvals.

View the file

Other files

File Type Posted
6-7-126_MINOS_G-02 GENERAL NOTES_REV01.pdf PDF
QandA-Minos Roof and Masonry Wall1_Response_Final.pdf PDF
SECTION 075419 - POLYVINYL-CHLORIDE (PVC) ROOFING_Amendment2.pdf PDF
Amend 02 to RFP ISD_384202_DA.pdf PDF
6-7-126_MINOS_G-01 COVER SHEET_REV01.pdf PDF
2.0 Price Proposal Form_Final_R1_fill-ins.pdf PDF
Pre-Proposal Sign In Sheet_Minos roof-wall_2nd Site Visit.pdf PDF
6-7-126_MINOS_A-01 PLAN - REV01.pdf PDF
Amend 01 to RFP ISD_384202_DA.pdf PDF
Second Site Visit-Business Visitor Registration Instructions and Directions.pdf PDF
Pre-Proposal Meeting-Sign in Sheet.pdf PDF
Exhibit C FFDG General Terms and Conditions for Construction (08.2025).pdf PDF
Exhibit D 2025 Construction Insurance Requirements.pdf PDF
Exhibit J PUR-466_Proposal Certifications_r5_10.14.25.pdf PDF
Exhibit Q Business Visitor Registration Instructions and Directions-MinosRoof_MasonryWall.pdf PDF
Attach A 6-7-126_SOW_Minos Roof_High Bay_wall repair_v5.pdf PDF
Exhibit L General Decision No IL20260008 Mod2_2026_0518.pdf PDF
Exhibit O 6-7-126 MINOS HIGH BAY ROOF_MASONRY WALL REPAIR_drawing set.pdf PDF
Exhibit F Payment Bond FL-42_FFDG.pdf PDF
2.0 Price Proposal Form_Final_fill-ins.pdf PDF
1.0 Request for Proposal_ISD_384202_DA.pdf PDF
Exhibit H Fermilab Subcontractor Safety Information Questionnaire.pdf PDF
Exhibit G Performance Bond FL-40_FFDG.pdf PDF
Exhibit K SARC_Subcontractor Annual RepsCerts Rev 8.pdf PDF
Exhibit E Bid Bond FL-41.pdf PDF
Exhibit N FL-61 (Rev. 1-07).pdf PDF
Exhibit R Fermilab Site Map-MINOS.pdf PDF
Exhibit M Sample FFP Subcontract.pdf PDF
Exhibit I SF1413_fill-ins.pdf PDF
Attach B 6-7-126_MINOS HB ROOF REPLACEMENT_PROJECT MANUAL_260803.pdf PDF
Exhibit P Summary of Required Solicitation Documents.pdf PDF
Show all 31

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BULK SAMPLE ASBESTOS EVALUATION BY

POLARIZED LIGHT MICROSCOPY METHOD

Client: Fermi Lab

Contact Jonny Staffa

TEM Project: 69570

Project Reference: Roof Samples

Analyzed by: Lori Boersma

Date Analyzed: 5/9/2023

Lab ID Color Filler

Binder

Comments

Fibrous Materials

Asbestos Fibers

Type Percent

Non-Asbestos Fibers

Type Percent

Client Sample ID

Sample Information

Address: Kirk & Wison Rds.

Batavia IL 60510-

Non-Fibrous Materials

Description

Project Location:

LABORATORY REPORT

Asbestos Present

481572 Black None Detected 70-80230504JS001

Transfer Berm NW Roof - Lab F

20-30Glass:

481573 Tan/Black None Detected 70-80230504JS002

White Patch SW Corner - Lab F

20-30Glass:

481574 Black Yes 90-95230504JS003

Fan Hatch Roofing - Lab F

5-10Chrysotile: --

481575 Black None Detected 95-97230504JS004

Transfer Berm NE Roof - Lab F

3-5Glass:

481576 Black None Detected 70-80230505JS001

Roof Flashing - MINOS

20-30Glass:

481577 Black None Detected 70-80230505JS002

Roof Flashing - MINOS

20-30Glass:

481578 Brown/Black None Detected 70-80230505JS003

Roof Center - F38FC

- - 15-20Cellulose:

5-10Glass:

481579 Brown/Black None Detected 70-80230505JS004

Roof Patch - F38FC

- - 15-20Cellulose:

5-10Glass:

Page 1 of 2TEM Project: 69570 NVLAP Lab Code: 101130-0

630-790-0880 INFO@TEM-INC.COM 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139

BULK SAMPLE ASBESTOS EVALUATION BY

POLARIZED LIGHT MICROSCOPY METHOD

Client: Fermi Lab

Contact Jonny Staffa

TEM Project: 69570

Project Reference: Roof Samples

Analyzed by: Lori Boersma

Date Analyzed: 5/9/2023

Lab ID Color Filler

Binder

Comments

Fibrous Materials

Asbestos Fibers

Type Percent

Non-Asbestos Fibers

Type Percent

Client Sample ID

Sample Information

Address: Kirk & Wison Rds.

Batavia IL 60510-

Non-Fibrous Materials

Description

Project Location:

LABORATORY REPORT

Asbestos Present

481580 Brown/Black None Detected 60-70230505JS005

Roof Flashing - F38FC

- - 20-25Cellulose:

10-15Glass:

481581 White None Detected 90-95230505JS006

Roof Membrane - NWA

5-10Synthettic

Report Approved by:

Samples are analyzed following the procedures contained in the USEPA Method 600/R-93/116 July 1993. This report applies only to samples analyzed. This report may not be reproduced except in full and with the approval of TEM Environmental, Inc. This report may not be used by the client to claim product endorsement by NVLAP or any agency of the US government. An estimate of the laboratory uncertainty is available upon request.

SLM: Certain samples may warrant additional analysis beyond the standard USEPA Polarized Light Microscopy method. 1) Further testing using the point count method is recommend for friable samples found to contain less than 10% asbestos by PLM to confirm that the samples are in fact regulated asbestos containing materials (RACM) as defined by the USEPA NESHAP Regulation.

2) The optical resolution of a polarized light microscope limits the size of fibers that are visible. In cases where very small fibers may be present, such as in samples of floor tiles, vermiculite or certain construction adhesives, the result of the PLM analysis is not conclusive when the sample is reported as "None Detected" or “Trace”. Further testing using transmission electron microscopy is recommended in those cases where samples may contain very small fibers which may be smaller than the resolution limit of a polarized light microscope. All such services are available for an additional fee.

Analytical services provided are subject to the Terms and Conditions listed on our website.

Page 2 of 2TEM Project: 69570 NVLAP Lab Code: 101130-0

630-790-0880 INFO@TEM-INC.COM 174 N BRANDON DRIVE GLENDALE HEIGHTS, ILLINOIS 60139