Statement of Objectives Construct New Security Gatehouse
CZQZ 17-9999
31 AUG2017
1. OBJECTIVE: Demolition of existing Gatehouse. Construct new gatehouse encompassing required ATFP upgrades.
2. WORK LOCATION: Sampleland AFB, NM.
3. PRINCIPAL FEATURES: The work required is to include but is not limited to the furnishing of materials, equipment, facilities, transportation, labor, and supervision required to accomplish the following:
3.1 Demo
3.1.1 Demo and remove existing guardhouse. Electrical/Communication risers are to be relocated from current location to new location, refer to conceptual drawings.
3 .1.2 Demo concrete within the curb footprint of existing island.
3.1.3 Trench from existing sewer and water lines located under backside of the existing pad to new service entrance of building.
3.2 Construct New Guardhouse
3.2.1 Construct footings to support a new 11' l l "'x32'8" Guardhouse. New guardhouse to be constructed with 4" CMU Split-face block. Match existing barrier wall block color.
3 .2.2 CMU shall be core filled with grout throughout. Shall have bond beams and lintels installed as required by prevailing code.
3 .2.3 Guardhouse shall have windows and doors to provide 180 degree visibility towards incoming traffic. Windows shall be specular-reflecting, low transmission glazing. 18 inch Security Mirrors shall be attached to supports to provide 360 degree visibility and shall not detract from forward viewing. Mirrors at rear of building shall be visible in front mirror viewing angle to accomplish this requirement. Windows shall comply to A TFP standards; UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings and UFC 04-022-01, Security Engineering: Entry Control Facilities/ Access Control Points.
3 .2.4 Guardhouse shall have an interior bathroom, a communications closet to house a floor mounted communication cabinet, and a utility closet which will also house a
· 150A electric panel. The main traffic observation room shall be in the front of the structure. Install a microwave shelf located on the wall outside the utility room adjacent to the main exit door, out ofwalkpath. Install a 24 inch deep counter along interior front of building for computer support.
3.2.5 The ceiling in the bathroom shall be hard ceiling; Narrow type suspended ceiling (white) to be installed with 2x2 tegular ceiling tile throughout the remaining areas.
CZQZ 17-9999 Page 1 of 6