The document provided is Exhibit N Ashland Community Center Bid & Permit Drawings (03.13.24).pdf, which contains bid and permit drawings related to the Community Center and Pioneer Hall Rehabilitation project in Jackson County, Oregon. The project involves the rehabilitation of the community center and pioneer hall facilities for Jackson County. The document provides detailed drawings and specifications for the construction work required as part of this project. No additional information is provided regarding response dates, due dates, site visits, bidder's meetings, award dates, contract term, or renewal options.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A101
SIM
A101
A101 1R e f
XX
Name Elevation
N
Room name
150 SF
A101
SIM
View Name A1.1
1/4" = 1'-0"
ROOM NAME
ROOM NUMBER
ROOM AREA
KEYNOTE TAG
REVISION SET TAG
1i
DOOR NUMBER
FINISH TYPE
WINDOW/GLAZING
TAG
LEVEL HEAD
SHEET REFERENCE
ELEVATION REFERENCE
ELEVATION SYMBOL
SHEET REFERENCE
INTERIOR ELEVATION
REFERENCE
INTERIOR
ELEVATION SYMBOL
SHEET REFERENCE
INTERIOR ELEVATION
REFERENCE
BUILDING & WALL
SECTION
SHEET REFERENCE
DRAWING
REFERENCE
DETAIL
REFERENCE
A101
SIM
SHEET REFERENCE
DRAWING
REFERENCE
ENLARGED
PLAN
DESIGNATED AREA
PROJECT NORTH
SHEET REFERENCE
VIEW TITLE
DRAWING SCALE
WALL TYPE TAG
STRUCTURAL
KEYNOTE TAG
CEILING TAG
FLOOR
TRANSITION TAG
CENTER LINE
DELTA w// CURRENT
REVISION NUMBER
PREVIOUS REVISION
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
NOTES
ACT
8'-0"
Remarks
EX#
EX#
ME#
ME#
XX#
XX# FLOOR FINISH
BASE FINISH
ADDITIONAL NOTES
WALL FINISHES
FINISH TAG
TR#
A101
Ref
R e f
R e f
Ref
SHEET REFERENCE
DRAWING
REFERENCE
PHOTO REFERENCE
FINISH TAG
XX
DRAWING NUMBER
1i PLUMBING FIXTURE TAG
1 Ref
R e f
1 Ref
R e f
X
ADDITIONAL KEYNOTE#
PROJECT LOCATION:
74 WINBURN WAY,
ASHLAND, OR 97520
PIONEER HALL
ASHLAND COMMUNITY CENTER - HATCH
INDICATES AREA OF WORK
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESS IONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7 , 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/1
/2
:4 :2
P
M A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
G0.00
COVER SHEET
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
ASHLAND COMMUNITY CENTER RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
100% CONSTRUCTION DOCUMENTS | BID & PERMIT
N
SHEET INDEX
A.B. ANCHOR BOLT
A.C. ASPHALT CONCRETE
A.C.B. ACOUSTICAL BOARD
ACI AMERICAN CONCRETE
INSTITUTE
A.C.P. ACOUSTICAL PANEL
A.C.T. ACOUSTICAL CEILING
TILE
ADD'L. ADDITIONAL
A.D. AREA DRAIN
ADJ. ADJUSTABLE
A.F. ACCESS FLOORING
AGGR. AGGREGATE
A.F.F. ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ARCH. ARCHITECT
ASCE AMERICAN SOCIETY OF
CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AWS AMERICAN WELDING
SOCIETY
BD. BOARD
BITUM. BITUMINOUS
BKP. BACKING PLATE
BM. BEAM
BOT./B.O. BOTTOM/BOTTOM OF
C.B. CATCH BASIN
CEM. CEMENT
CER. CERAMIC
C.G. CORNER GUARD
C.I. CAST IRON
C.J. CONTROL JOINT
CJP COMPLETE JOINT
PENETRATION
CL CENTERLINE
CLG. CEILING
CLKG. CAULKING
CLO. CLOSET
CLR. CLEAR
CMU CONCRETE MASONRY
UNIT
C.O. CASED OPENING
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CORR. CORRIDOR
CPT. CARPET
CTSK. COUNTERSUNK
C.T. CERAMIC TILE
CTR. CENTER
DBA DEFORMED BAR
ANCHOR
D.F. DRINKING FOUNTAIN
D.L. DEAD LOAD
DET. DETAIL
DIA., ⌀ DIAMETER
DISP. DISPENSER
DR. DOOR
DWG. DRAWING
DWR. DRAWER
D.S. DOWNSPOUT
D.S.P. DRY STANDPIPE
(E) EXISTING
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
EL. ELEVATION
EQ. EQUAL
EXPO. EXPOSED
EXP. EXPANSION
EXT. EXTERIOR
F.A. FIRE ALARM
FB. FLAT BAR
F.D. FLOOR DRAIN
FDN. FOUNDATION
FE FIRE EXTINGUISHER
F.H. FLAT HEAD
FIN. FINISH
FLR. FLOOR
F.O.C FACE OF CONCRETE
F.O.F FACE OF FINISH
F.O.S. FACE OF STUDS
F.S. FULL SIZE
FT. FOOT
FTG. FOOTING
FUT. FUTURE
Ga. GAUGE
GALV. GALVANIZED
GL GRID LINE
GLB GLULAM BEAM
G.B. GRAB BAR
GND. GROUND
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
H.B. HOSE BIBB
H.C. HOLLOW CORE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL
STEEL
IBC INTERNATIONAL
BUILDING CODE
I.D. INSIDE DIAMETER
IN. INCH
INT. INTERIOR
J.B. JUNCTION BOX
J.O.H. JAMB OPENING HEIGHT
J.O.W. JAMB WIDTH
JT. JOINT
K KIPS
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
LAM. LAMINATE
LB. POUND
L.L. LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC. LOCATION
LONG. LONGITUDINAL
L.P. LOW POINT
LVF LOW VELOCITY FASTENER
MAX. MAXIMUM
MBMA METAL BUILDING
MANUFACTURERS
ASSOCIATION
M.C. MEDICINE CABINET
M.D.F. MEDIUM DENSITY
FIBERBOARD
M.D.O. MEDIUM DENSITY
OVERLAY
MECH. MECHANICAL
MEMB. MEMBRANE
MFR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
M.P. MIDPOINT
MPH MILES PER HOUR
M.S. MACHINE SCREW
MT MAGNETIC PARTICLE
TESTING
MTD. MOUNTED
MUL. MULLION
(N) NEW
N.I.C. NOT IN CONTRACT
NOM. NOMINAL
N.T.S. NOT TO SCALE
OBS. OBSCURE
o.c. ON CENTER
O.C.D. OVERHEAD COILING
DOOR
O.C.G OVERHEAD COILING
GRILLE
O.D. OUTSIDE DIAMETER
O.F.C.I. OWNER FURNISHED
CONTRACTOR
INSTALLED
O.F.D. OVERFLOW DRAIN
O.F.O.I. OWNER FURNISHED
OWNER INSTALLED
OH. OPPOSITE HAND
OPP. OPPOSITE
OWJ OPEN WEB JOIST
-GENERAL-
G0.00 COVER SHEET
G1.00 CODE PLAN - COMMUNITY CENTER
G2.00 TYPICAL ADA STANDARDS - EXISTING
G2.10 TYPICAL ADA STANDARDS - EXISTING
-ARCHITECTURAL-
A0.00 ASSEMBLIES AND DOOR SCHEDULES
A0.10 FINISH SCHEDULES
A1.00 FLOOR PLAN
A1.10 ROOF PLAN
A2.00 REFLECTED CEILING PLAN
A3.00 FINISH FLOOR PLAN
A4.00 EXTERIOR ELEVATIONS
A4.10 EXTERIOR ELEVATIONS
A5.00 BUILDING SECTIONS
A5.10 WALL SECTIONS
A6.00 STAIRS AND RAMP SECTIONS
A7.00 ENLARGED PLANS & INTERIOR ELEVATIONS
A7.10 ENLARGED PLANS & INTERIOR ELEVATIONS
A7.11 ENLARGED PLANS & INTERIOR ELEVATIONS
A8.00 EXTERIOR DETAILS
A8.10 EXTERIOR DETAILS
A9.00 INTERIOR DETAILS
OWNER:
CONTACT: JASON STRAIGHT PM
CITY OF ASHLAND PUBLIC WORKS
51 WINBURN WAY
ASHLAND, OR 97520
T 541.552.2419
ARCHITECTURE:
STAMPING REGISTRANT: ZACH STOKES, P.E.
CONTACT: JESSI RUSSELL, ARCHITECT
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
STRUCTURAL ENGINEERING:
ENGINEER OF RECORD: MATT SMITH P.E. S.E.
CONTACT: STEPHEN CHASE
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
CIVIL ENGINEERING:
ENGINEER OF RECORD: SYLAS ALLEN, P.E.
CONTACT: LUCAS GOWEY
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
SURVEY:
CONTACT: JOHN R. PARIANI PLS
PARIANI LAND SURVEYING
17 S PLATT ST. SUITE C
EAGLE POINT, OR 97524
T 541.890.1131
GENERAL CONTRACTOR:
TBD
1. ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS
SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL
NOTIFY THE PROJECT TEAM OF ANY SIGNIFICANT
DISCREPANCIES FROM CONDITIONS SHOWN ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
ALL CONSTRUCTION MEANS AND METHODS.
RESPONSIBILITY SHALL INCLUDE BUT NOT LIMITED TO
DEMOLITION AND CONSTRUCTION MEANS AND METHODS,
TECHNIQUES, SEQUENCING, AND SAFETY REQUIRED TO
COMPLETE CONSTRUCTION.
3. BEFORE STARTING A SECTION OF WORK THE
CONTRACTOR SHALL CAREFULLY EXAMINE PREPARATORY
WORK THAT HAS BEEN EXECUTED. ENSURE THAT WORK
AND ADJACENT RELATED WORK WILL FINISH TO PROPER
PLANES AND LEVELS.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
ALL MATERIALS AND WORKMANSHIP IN ACCORDANCE
WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL
CODES.
5. CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL
CONTRACT DOCUMENTS, FIELD CONDITIONS, AND
DIMENSIONS FOR ACCURACY AND CONFIRMING THAT
WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING
WITH THE CONSTRUCTION. IF THERE ARE ANY QUESTIONS,
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A
CLARIFICATION FROM THE PROJECT TEAM BEFORE
PROCEEDING WITH THE WORK IN QUESTION OR RELATE
WORK.
6. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. WRITTEN
DIMENSIONS SHALL ALWAYS GOVERN. CONTRACTOR
REQUIRING DIMENSIONS NOT NOTED SHALL ALWAYS
CONTACT THE PROJECT TEAM FOR SUCH INFORMATION
PRIOR TO PRECEDING WITH WORK RELATED TO THOSE
DIMENSIONS
7. THE CONTRACTOR SHALL PROTECT, PATCH, AND REPAIR
TO MATCH ANY WALLS, FLOORS, CEILINGS, AND/OR OTHER
SURFACES WHICH MAY BE DISTURBED DURING THE
INSTALLATION OF MECHANICAL, ELECTRICAL, PLUMBING
OR OTHER OWNER WORK.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING AND PATCHING REQUIRED FOR PROPER
INSTALLATION OF MATERIAL AND EQUIPMENT. PROVIDE
DEMOLITION AND PATCH/REPAIR IN ALL AREAS (WHETHER
SPECIFICALLY SHOWN OR NOT) TO ACCOMMODATE ALL
WORK.
9. IF THE CONTRACTOR ENCOUNTERS A CONDITION NOT
COVERED IN THE CONSTRUCTION DOCUMENTS, THE
CONTRACTOR SHALL NOTIFY AND RESOLVE THE ISSUE
WITH THE PROJECT TEAM BEFORE COMMENCING ANY
WORK.
10. ALL PERMITS ASSOCIATED WITH THE PROJECT SHALL BE
PAID AND OBTAINED BY THE CONTRACTOR.
11. GENERAL CONTRACTOR SHALL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR JOB CONDITIONS OF THE
JOB SITE, INCLUDING SAFETY OF PERSONS AND PROPERTY
AND COMPLIANCE WITH OSHA SAFETY STANDARDS.
12. WHEN PORTIONS OF THE WORK ARE PERFORMED BY THE
CONTRACTOR ON A DESIGN-BUILD BASIS, THE
CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
DESIGN OF SUCH SYSTEMS AND FOR THE SECURING OF
ALL ASSOCIATED PERMITS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE COORDINATION OF ALL DESIGN
BUILD SUB CONTRACTORS.
13. CONTRACTOR SHALL AVOID INTERFERENCE AND CONFLICT
WITH THE BUILDING'S NORMAL OPERATION. CONTRACTOR
TO COMPLY WITH THE BUILDING RULES AND REGULATIONS
REGARDING SCHEDULING AND USE OF ELEVATORS AND
LOADING DOCKS FOR DELIVERY AND HANDLING OF
MATERIALS, EQUIPMENT, AND DEBRIS.
14. ALL KEY NOTES INDICATE NEW ITEMS TYPICALLY U.N.O.
15. CONTRACTOR TO REVIEW ABATEMENT REPORT PRIOR TO
START OF CONSTRUCTION.
PAF POWDER ACTUATED
FASTENER
P/C PRECAST (CONCRETE)
PCF POUNDS PER CUBIC
FOOT
PL PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
P.C.P. PORTLAND CEMENT
PLASTER
PJP PARTIAL JOINT
PENETRATION
PR. PAIR
PSF POUNDS PER FOOT
PSI POUNDS PER INCH
P/T POST-TENSIONED
P.T. PRESSURE TREATED
PTN. PARTITION
(R) REMOVE
R., RAD. RADIUS
R.C.P. REFLECTED CEILING
PLAN
R.D. ROOF DRAIN
REF. REFERENCE
REINF. REINFORCING
REQ'D. REQUIRED
RL. RELOCATE
R.O. ROUGH OPENING
RWD. REDWOOD
REV. REVERSED
S.C. SOLID CORE or SLIP
CRITICAL
S.C.D. SEE CIVIL DRAWINGS
SCHED. SCHEDULE
SHR. SHOWER
SIM. SIMILAR
S.J. SCORE JOINT
S.L.D. SEE LANDSCAPING
DRAWINGS
SLRS SEISMIC LOAD RESISTING
SYSTEM
S.M. SHEET METAL
S.M.D SEE MECHANICAL
DRAWINGS
S.O.G. SLAB ON GRADE
SPEC. SPECIFICATION
SQ. SQUARE
S.S.D. SEE STRUCTURAL
DRAWINGS
S.S. STAINLESS STEEL
SSMA STEEL STUD
MANUFACTURERS
ASSOCIATION
STD. STANDARD
STRUCT. STRUCTURAL
S.T.S. SELF TAPPING SCREW
SUSP. SUSPENDED
SYM. SYMMETRICAL
THRU THROUGH
TYP. TYPICAL
TRD. TREAD
T.B. TOWEL BAR
T.C. TOP OF CURB
T & G TONGUE AND GROOVE
THK. THICK
TJ TRUSS JOIST
T.P. TOP OF PAVEMENT
TRANS. TRANSVERSE
T.W. TOP OF WALL
U.N.O. UNLESS NOTED
OTHERWISE
U.T. ULTRASONIC TESTING
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
V.T.R. VENT THROUGH ROOF
w/ WITH w/o WITHOUT
W.C. WATER CLOSET
WF WIDE FLANGE
W.O. WINDOW OPENING
W.P. WORK POINT
EXTERIOR PHOTOPROJECT NOTES PROJECT TEAMABBREVIATIONS PROJECT NARRATIVE SHEET INDEX
AERIAL PHOTO
SYMBOLS LEGEND
VICINITY MAP
N
-DEMO-
D1.00 DEMO FLOOR PLAN
D1.10 DEMO ROOF PLAN
D2.00 DEMO REFLECTED CEILING PLAN
D3.00 DEMO EXTERIOR ELEVATIONS
D4.00 DEMO PHOTOS
PROJECT SCOPE:
THE SCOPE OF THIS PROJECT CONSISTS OF VOLUNTARY STRUCTURAL
IMPROVEMENTS TO THE EXISTING ROOF FRAMING, EXISTING FLOOR FRAMING, AND
ADDITIONAL IMPROVEMENTS FOR ACCESSIBILITY AND ADA PURPOSES.
-CIVIL-
C0.00 CIVIL COVER SHEET
C0.01 EROSION AND SEDIMENT CONTROL NOTES
C1.00 EXISTING CONDITIONS AND DEMOLITION PLAN
C2.00 SITE IMPROVEMENT PLAN
C3.00 PRIVATE CIVIL DETAILS
C4.00 AGENCY STANDARD DETAILS
ALTERNATES
A. (N) ADA ACCESSIBLE KITCHEN AND LIGHTING
B. PAINT EXTERIOR SIDING AND TRIM AT FRONT ELEVATION TO MATCH (E)
C. (N) RAMP
D. REFINISH (E) WOOD FLOORS
E. PAINT ALL INTERIOR WALLS, DOORS, AND TRIM
F. INSTALL (N) CARPET TILES
G. (N) CONCRETE SIDEWALK, STORM IMPROVEMENTS, AND DOWNSPOUT BOOT
REPLACEMENT
H. PAINT ENTIRE EXTERIOR SIDING AND TRIM
-STRUCTURAL-
S0.10 STRUCTURAL GENERAL NOTES
S1.10 FOUNDATION PLAN
S2.10 CEILING FRAMING PLAN
S3.10 ROOF FRAMING PLAN
S4.10 TRUSS ELEVATIONS
S4.11 TRUSS DETAILS
S5.10 FOUNDATION DETAILS
S6.10 FRAMING DETAILS
DESIGN BUILD SCOPE
G.C. AND SUBCONTRACTORS TO REVIEW PLANS, VERIFY EXISTING CONDITIONS AND
PROVIDE CODE REQUIRED MEP DESIGN IN COORDINATION WITH THE
ARCHITECTURAL PLANS. FURTHER MODIFICATIONS MAY BE REQUIRED.
MECHANICAL:
1. DEMO (E) EXHAUST FANS AND REPLACE WITH (N)
2. DEMO (E) FLOOR VENTS AND REPLACE WITH (N)
3. DEMO (E) GAS HVAC SYSTEM AND REPLACE WITH (N) ELECTRIC HVAC
SYSTEM. RE-USE (E) DUCTWORK. REMOVE AND REINSTALL (E) DUCTS AS
NECESSARY FOR STRUCTURAL UPGRADES
PLUMBING:
1. DEMO (E) PLUMBING FIXTURES AND REPLACE WITH (N) - RECONFIGURE
WATER AND WASTE LINES AS NECESSARY TO ACCOMMODATE (N) PLUMBING
FIXTURES
ELECTRICAL:
1. REMOVE (E) ELECTRICAL PANEL AND REINSTALL AS REQUIRED TO COMPLETE
STRUCTURAL SCOPE. PAINT CONDUIT TO MATCH
2. DEMO (E) LIGHT FIXTURES AND REPLACE WITH (N)
3. PROVIDE POWER FOR (N) SUMP PUMP
DEFERRED SUBMITTALS
ZCS SHALL PERFORM GENERAL REVIEW OF ANY DEFERRED
SUBMITTAL DESIGNS PRIOR TO SUBMITTING TO THE AHJ AND
PRIOR TO CONSTRUCTION IMPLEMENTATION FOR GENERAL
CONFORMANCE TO THE DESIGN INTENT. DEFERRED SUBMITTAL
ITEMS SHALL NOT BE SPECIALLY FABRICATED OR INSTALLED UNTIL
APPROVED BY THE AHJ AND ZCS.
REVISION ID: DATE:
WH
D W
UP
UP
FIRE LIFE SAFETY LEGEND
EXIT
Room name
OccType
# occs.
150 sf OLF /sf
# Exit(s)
FE
ILLUMINATED EXIT SIGN PER 2022
OREGON FIRE CODE (OFC)
EMERGENCY EXIT ROUTE
ROOM OCCUPANT LOAD
FIRE EXTINGUISHER
OCCUPANCY LOAD VALUE ALONG
EGRESS ROUTE
1 2 3 4 5
A
B
C
D
E
162 SF
STAGE
A-1
11 occs.
15 /sf
1 Exit(s)
163 SF
STORAGE
S-1
1 occs.
300 /sf
1 Exit(s)
112 SF
STORAGE
S-1
1 occs.
300 /sf
1 Exit(s)
181 SF
HALLWAY
92 SF
OFFICE
B
1 occs.
150 /sf
1 Exit(s)
401 SF
OFFICE
B
3 occs.
150 /sf
1 Exit(s)
207 SF
OFFICE
B
2 occs.
150 /sf
1 Exit(s)
172 SF
KITCHEN
A-2
1 occs.
200 /sf
1 Exit(s)
19 SF
PANTRY
S-1
1 occs.
300 /sf
1 Exit(s)
22 SF
SIDE STAGE
21 SF
STORAGE ENTRY
EXIT PATH 'A/B'
EXIT PATH 'A'
EXIT ACCESS
DISTANCE: 77'
/2
EXIT
EXIT
' - 6
/2
1491 SF
MAIN HALL
A-3
213 occs.
7 /sf
2 Exit(s)
1/ 4"
33' - 1 3/4"
EXIT PATH 'B'
EXIT ACCESS
DISTANCE: 98'
11 SF
JAN.
S-1
1 occs.
300 /sf
1 Exit(s)
105A
E X
IT
UP
UP
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESS IONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7 , 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/1
/2
:4 :2
P
M A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
G1.00
CODE PLAN -
COMMUNITY
CENTER
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
SCOPE
THE SCOPE OF THE PROJECT IS TO PERFORM
STRUCTURAL UPGRADES AND ADA IMPROVEMENTS TO
THE EXISTING COMMUNITY CENTER. EXISTING
FINISHES/FIXTURES WILL BE REMOVED AND REPLACED TO
CORRECT STRUCTURAL DEFICIENCIES WITH THE EXISTING
FOUNDATION, FLOOR FRAMING, AND ROOF FRAMING. THE
STRUCTURAL UPGRADES ARE DESIGNED TO MEET
CURRENT CODE LEVELS FOR LOADING. THE FRONT
ENTRY TO THE BUILDING WILL BE RECONSTRUCTED TO
PROVIDE A NEW RAMP, STAIRWAY AND CONCRETE PORCH
WHICH ALL MEET ADA ACCESSIBILITY REQUIREMENTS.
WITHIN THE BUILDING, ADA IMPROVEMENTS INCLUDE NEW
ACCESSIBLE RESTROOMS, AN ACCESSIBLE KITCHEN, A
RAMP WHICH PROVIDES ACCESS TO THE STAGE, AND
WIDENING OF EXISTING DOORWAYS.
THERE WILL BE NO CHANGE IN OCCUPANCY TO THE
BUILDING. OSSC SECTION 1006.3.3 REQUIRES THE
BUILDING TO HAVE TWO EXITS. ONE EXIT IS PROVIDED AT
THE FRONT OF THE BUILDING LEADING DIRECTLY TO THE
RIGHT OF WAY. THE SECOND EXIT IS AT THE BACK SIDE OF
THE BUILDING, LEADING ONTO TO A NEW WOOD DECK
(REBUILT TO MEET ADA’S REQUIREMENTS FOR FLOOR
SURFACES AND STAIRS), AND THROUGH AN EXISTING
NON-CONFORMING EGRESS COURT ALONG THE SOUTH
SIDE OF THE BUILDING. THERE IS AN EXISTING STAIRWAY
ON THE NORTH SIDE OF THE BUILDING WHICH IS
RESTRICTED BY THE NEIGHBORING PARKING LOT AND
UTILITY EQUIPMENT LOCATED ALONG THE PEDESTRIAN
SIDEWALK. PER OSSC SECTION 1028.5, THIS PATH DOES
NOT PROVIDE UNOBSTRUCTED ACCESS TO THE RIGHT OF
WAY, DOES NOT PROVIDE A SAFE DISPERSAL AREA, AND IS
NOT CONSIDERED A VIABLE EXIT. THE STAIRS MUST BE
DEMOLISHED TO CONSTRUCT A NEW STEM WALL ON THE
NORTH SIDE AND WILL NOT BE REBUILT. THE EXISTING
DOORWAY AT THE TOP OF THE STAIRS WILL BE INFILLED
WHICH WILL ALLOW SPACE FOR THE NEW ADA STAGE
RAMP TO BE CONSTRUCTED. ALTHOUGH OSSC SECTION
3403.6.7.2 STATES THAT ACCESSIBLE MEANS OF EGRESS
ARE NOT REQUIRED TO BE ADDED IN EXISTING FACILITIES,
THE NEW ACCESSIBLE FRONT ENTRY/EXIT HAS BEEN
INCORPORATED INTO THE DESIGN FOR THE BENEFIT OF
THE COMMUNITY.
APPLICABLE CODES
BUILDING CODE 2022 OSSC
PLUMBING CODE 2023 OPSC
MECHANICAL CODE 2022 OMSC
ELECTRICAL CODE 2023 OESC
ENERGY SPECIALITY CODE 2021 OEESC
ACCESSIBILITY 2017 ICC A117.1
FIRE CODE 2022 OFC
LOT INFORMATION
74 WINBURN WAY, ASHLAND, OR 97520
BUILDING INFORMATION
CONSTRUCTION TYPE VB
(E) BUILDING AREA 3,642 SF
BUILDING AREA ALLOWED 5,500 SF
(E) NUMBER OF STORIES 1
STORIES ALLOWED 1
(E) BUILDING HEIGHT 23'-10" ±
BUILDING HEIGHT ALLOWED 40'-0"
FIRE SPRINKLER NO
FIRE ALARM NO
OCCUPANCY
A-1 OCC 11 OCCUPANTS
A-2 OCC 1 OCCUPANT
A-3 OCC 213 OCCUPANTS
B OCC 6 OCCUPANTS
S-1 4 OCCUPANTS
TOTAL 235 OCCUPANTS
EGRESS REQUIREMENTS
NUMBER OF EXITS REQUIRED: 2
NUMBER OF EXITS PROVIDED: 2
EXIT ACCESS TRAVEL DISTANCE: 200 FT
(OSSC SECTION 1017.2)
LONGEST DISTANCE PROPOSED: 98 FT
COMMON PATH OF EGRESS TRAVEL 75 FT
(OSSC SECTION 1006.2.1)
LONGEST DISTANCE PROPOSED: 54 FT
EGRESS PATH MIN. WIDTH: 3'-10"
(OCCUPANT LOAD X 0.2")
ACCESSIBLE MEANS OF EGRESS:
PER 3403.6.7.2, ACCESSIBLE MEANS OF EGRESS
REQUIRED BY CHAPTER 10 ARE NOT REQUIRED TO BE
ADDED IN EXISTING FACILITIES
G1.00 3/16" = 1'-0"
CODE PLAN - COMMUNITY CENTER1
N
OCCUPANCY LOAD PER ROOM
# Room Name Area OccType OccLoad Calc
111 STAGE 162 SF A-1 11
109 KITCHEN 172 SF A-2 1
101 MAIN HALL 1491 SF A-3 213
106 OFFICE 92 SF B 1
103 OFFICE 401 SF B 3
102 OFFICE 207 SF B 2
112 STORAGE 163 SF S-1 1
113 STORAGE 112 SF S-1 1
116 PANTRY 19 SF S-1 1
105A JAN. 11 SF S-1 1
LIFE SAFTEY CODE SUMMARY
ENERGY CODE REQUIREMENTS:
CLIMATE ZONE 4 - NON RESIDENTIAL
ROOF: ATTIC R-49
WALL: WOOD FRAMED R-20
DOORS: U-0.370
FENESTRATION: FIXED: U 0.36 MAX, SHGC 0.36 MAX
OPERABLE : U .45 MAX, SHGC 0.33 MAX
TOTAL PROVIDED 2 2
TOTAL REQUIRED 3.2 = 4 1.3 = 2
STORAGE 4 1/100 1/100 .04 .04
BUSINESS 6 1/25 1/40 0.24 0.15
ASSEMBLY 219 1/75 1/200 2.92 1.095
TOTAL TOTAL MALE/FEMALE MALE/FEMALE
TOTAL
W/C LAV W/C LAVGROUP
OCC LOAD FIXTURE RATIOS FIXTURE REQUIREMENTS
PLUMBING COUNT PER TABLE 2902.1
M
A X
M
IN
12" MAX
1"
1-1/2" MIN. CLR.
STAIR HANDRAIL & EXTENSIONS RAMP HANDRAIL & EXTENSIONS
12" MIN.
CONTINUE TO SLOPE FOR
THE DEPTH OF ONE TREAD
BEYOND THE BOTTOM RISER
NOTES:
1. HANDRAILS SHALL BE PROVIDED ON BOTH SIDES OF STAIRS AND RAMPS.
2. HANDRAILS SHALL BE CONTINUOUS WITHIN FULL LENGTH OF EACH
STAIR FLIGHT OR RAMP RUN. INSIDE HANDRAILS ON SWITCHBACK OR
DOGLEG STAIRS OR RAMPS SHALL BE CONTINUOUS BETWEEN FLIGHT
FLIGHTS AND RUNS.
3. HANDRAIL HEIGHT SHALL BE MEASURED VERTICALLY ABOVE NOSINGS,
RAMP SURFACES AND WALKING SURFACES.
4. GRIPPING SURFACES SHALL BE CONTINUOUS, WITHOUT INTERRUPTION
BY NEWEL POSTS, OTHER CONSTRUCTION ELEMENTS, OR
OBSTRUCTTIONS.
5. HANDRAIL CROSS SECTIONS:
A. CIRCULAR: 1 1/14" MIN. - 2" MAX.
B. NONCIRCULAR PERIMETER: 4" MIN. - 6 1/4" MAX.
C. NONCIRCULAR CROSS SECTION: 2 1/4" MAX.
6. HANDRAIL EXTENSIONS SHALL RETURN TO A WALL, GUARD, OR FLOOR,
OR SHALL BE CONTINUOUS TO THE HANDRAIL OF AN ADJACENT RAMP
RUN OR AN ADJACENT STAIR FLIGHT.
12" MIN. 12" MIN.
FIXTURES DIM# MOUNTING HEIGHT
B
C
D
E
F
G
I
J
K
L
M
N
O
Q
R
EXTEND 42" MIN FROM THE SIDE WALL
TOILET 16" MIN - 18" MAX TO CENTER FROM SIDE WALL
URINAL (ADA) 17" TO RIM A.F.F
URINAL 24" TO RIM A.F.F.
SINK (ADA) 34" MAX TO THE HIGHER OF THE RIM OR COUNTER SURFACE
MIRROR 40" MAX TO BOTTOM EDGE OF REFLECTING SURFACE
HORIZONTAL GRAB BAR 33" MIN - 36" MAX HEIGHT A.F.F. TO T.O. GRIPPING SURFACE
VERTICAL GRAB BAR 39" MIN - 41" MAX HEIGHT A.F.F.
18" MIN IN LENGTH
SIDE WALL GRAB BAR 12" MAX FROM REAR WALL
42" MIN IN LENGTH
EXTEND 54" MIN FROM REAR WALL
39" MIN - 41" MAX FROM THE REAR WALL TO CENTERLINE OF BAR
TOILET 17" MIN - 19" MAX TO T.O. SEAT A.F.F.
18" MIN. TO OUTLET OF DISPENSOR A.F.F.
1 1/2" MIN. FROM B.O. GRAB BAR
24" MIN - 36" MAX FROM WALL TO OUTLET OF DISPENSOR
42" MAX FROM WALL TO OUTLET OF DISPENSOR
H
D
J K
N O
G H
E
F
D
A
REAR WALL GRAB BAR A 36" MIN IN LENGTH
6" MAX.
B
C
I
M
L
R
Q
P
REAR WALL GRAB BAR
G
VERTICAL GRAB BAR
SIDE WALL GRAB BAR
SIDE WALL GRAB BAR
VERTICAL GRAB BAR
TOILET PAPER AND
SEAT COVER DISPENSER
TOILET PAPER DISPENSER
TOILET PAPER DISPENSER
S
S
48" MAX A.F.F. TO HIGHEST OPERABLE PARTS OR
44" MAX A.F.F. IF OVER AN OBSTRUCTION W/ A DEPTH OF >20"
ACCESSORY DISPENSERS
P
P
WATER CLOSET CLEARANCE SIZE - SECTION 604.3
AMBULATORY ACCESSIBLE TOILET COMPARTMENT - SECTION 604.10
LAVATORY CLEAR FLOOR SPACE LAVATORY KNEE AND TOE CLEARANCE
M
IN
8" MIN
CLEARANCE
11" MIN KNEE
CLEARANCE
6" MAX TOE
M
IN
M
IN
59" MIN. FLOOR MOUNT
56" MIN. WALL HUNG
NOTE:
THE REQUIRED CLEARANCE AROUND THE
WATER CLOSET SHALL BE PERMITTED TO
OVERLAP THE WATER CLOSET,
ASSOCIATED GRAB BARS, PAPER
DISPENSERS, SANITARY NAPKIN
RECEPTACLES, COAT HOOKS, SHELVES,
ACCESSIBLE ROUTES, CLEAR FLOOR
SPACE AT OTHER FIXTURES AND THE
TURNING SPACE. NO OTHER FIXTURES OR
OBSTRUCTIONS SHALL BE WITHIN THE
REQUIRED WATER CLOSET CLEARANCE
M
IN
48" MIN.
TYPICAL MOUNTING REQUIREMENTS
60" MIN.
DOOR SHALL NOT SWING INTO
THE REQUIRED MINIMUM AREA
OF THE COMPARTMENT
M
IN
4" MAX.
56" MIN.
OR
M A
X
F L O
O R
M O
U N
T E
D
M
IN
W A
L L
H U
N G
M
IN
O R
O R
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT & DOOR OPENING LOCATION - SECTION 604.9
37" MAX.
35" MIN.
17" MIN. - 19" MAX.
M
IN
M
IN
56" MIN. WALL HUNG (ADULT)
59" MIN. FLOOR MOUNTED (ADULT)
59" MIN. WALL & FLOOR MOUNT (CHILDREN)
T
TBABY CHANGING TABLE 28" MIN - 34" MAX HEIGHT A.F.F.
TOILET PAPER AND
SANITARY NAPKIN
DISPENSER
NOTE:
LETTERS AND NUMBERS ON SIGNS SHALL BE
RAISED 1/32" MIN. AND SHALL BE SANS-SERIF
UPPERCASE CHARACTERS ACCOMPANIED BY
CONTRACTED GRADE 2 BRAILLE WITH A
CONTRASTING BACKGROUND.
PICTOGRAMS SHALL HAVE A
NONGLARE FINISH AND
SHALL CONTRAST WITH
THEIR FIELDS
RESTROOM SIGN LOCATION
GENERAL SIGNAGE REQUIREMENTS
WOMENHEIGHT OF
CHARACTERS SHALL BE
5/8" MIN. TO 2" MAX.
BRAILLE SHALL BE
CONTRACTED GRADE II
SIGN SHALL BE PROVIDED
ON LATCH SIDE OF DOOR
RAISED CHARACTERS SHALL
BE 48" MIN. A.F.F. MEASURED
TO BASELINE OF LOWEST
RAISED CHARACTER AND 60"
MAX. A.F.F. TO THE HIGHEST
RAISED CHARACTER
M
IN
F
IE
L
D
STAIR TREADS AND RISERS - SECTION 504
M A
X
M
IN
11" MIN.
TREADS AND RISERS
STAIR NOSINGS - VERTICAL RISER
CURVE OR BEVEL AT LEADING EDGE
1/2" MAX. ROUNDED 1/2" MAX. BEVEL
.0
1 1/2" MAX.
CURVED
CURVED NOSING
BEVELED NOSING
1 1/2" MAX.
BEVELED
30° MAX.
ANGLED RISER
NOTES:
1. ALL STEPS ON A FLIGHT OF STAIRS SHALL HAVE A
UNIFORM RISER HEIGHT AND UNIFORM TREAD DEPTH.
2. OPEN RISERS SHALL NOT BE PERMITTED.
3. NOSINGS WITHIN A STAIRWAY SHALL BE UNIFORM.
4. NOSINGS THAT PROJECT BEYOND RISERS SHALL HAVE
THE UNDERSIDE OF THE LEADING EDGE CURVED OR
BEVELED.
5. VISUAL CONTRAST SHALL COMPLY WITH EITHER A OR B:
A. THE LEADING 1" - 2" OF EVERY TREAD AND
LANDING, MEASURED HORIZONTALLY FROM THE
LEADING EDGE OF THE NOSING, SHALL CONSIST
OF A SOLID COLOR HAVING VISUAL CONTRAST
OF DARK-ON-LIGHT OR LIGHT-ON-DARK FROM
THE REMAINDER OF THE TREAD. THE
CONTRASTING MARKING SHALL BE DURABLE
AND SHALL EXTEND FROM ONE SIDE OF EACH
TREAD TO THE OTHER SIDE OF EACH TREAD.
B. DURABLE DISTINCTIVE WARNING MARKINGS
REQUIRED BY THE ADOPTED BUILDING CODE OR
ANSI SAFETY SANDARD.
HANDRAILS - SECTION 505
HANDRAIL CLEARANCE
52" MIN.
M
IN
C H
IL
D
R E
N
A D
U L T
M
A X
M
A X
S T
A N
D
IN
G U
S E
C
H
IL
D R
E N
M
IN
M
A X
M
IN
M
A X
S T
A N
D
IN
G U
A
D U
L T
DRINKING FOUNTAINS - SECTION 602
CLEAR FLOOR SPACE
& SPOUT LOCATION
WHEELCHAIR DRINKING FOUNTAIN
SPOUT HEIGHT & LOCATION
5" MAX.
ADULT
15" MIN.
STANDING USE DRINKING FOUNTAIN
SPOUT HEIGHT & LOCATION
NOTE:
WHERE BOTTLE FILLING STATIONS ARE
PART OF THE DRINKING FOUNTAIN FOR
PERSONS WHO ARE STANDING, THE
BOTTLE FILLING STATION IS NOT REQUIRED
TO COMPLY WITH THIS SECTION PROVIDED
A BOTTLE FILLING STATION IS LOCATED AT
THE DRINKING FOUNTAIN FOR PERSONS
USING WHEELCHAIRS.
DOOR SWINGING IN ON
FRONT WALL OF PARTITION
DOOR SWINGING IN ON
SIDE WALL OF PARTITION
8"
" 1
M
IN
PARTITION
8"
TOE CLEARANCE - PLAN TOE CLEARANCE - ELEVATION
DOOR SWING INTO THE WHEELCHAIR
TOILET COMPARTMENT
URINALS - SECTION 605
13 1/2" MIN.
M A
X
13 1/2" MIN.
WALL HUNG TYPE STALL TYPE
LAVATORIES - SECTION 606
Back wall
Seat wall
Control wall
TRANSFER-TYPE COMPARTMENT CLEARANCES (EXISTING BUILDINGS) - SECTION 608
48" MIN.
M
IN
M
IN
36" MIN.
SIGNAGE, IDENTIFICATION & INTERNATIONAL SYMBOLS OF ACCESSIBILITY - SECTION 703
EXIT
EXIT
FIRE APPLIANCESEXIT SIGNS, LIGHT SWITCHES & OUTLETS
MISCELLANEOUS MOUNTING HEIGHTS
FIRE EXTINGUISHER
OR FIRE HOSE CAB
FIRE ALARM
PULL
ALARM
STROBE
CLOCK
TACK, CHALK, OR
DRY MARKER
BOARD
HOSE
BIBB
SHELF
AND ROD
COAT
HOOKS
CLOSET
ROD
LOW LEVEL
EXIT SIGN
WHERE
REQUIRED
SURFACE-
MOUNTED
ILLUMINATED
EXIT SIGN
3"
9"
M
A X
M
IN
LIGHT
SWITCH
M
A X
M
IN
OUTLET
M
A X
M
IN
WITHIN 5 FT OF EACH
EXIT DOORWAY ON
EACH FLOOR
M
IN
M
A X
M
A X
M
IN
M
A X
M
A X
M
A X
M
IN
V A
R
IE
M
A X
IC
C
A .1
E
X
IS
T
IN
G B
U
IL
D
IN
G
127 NW D Street, Grants Pass, Oregon 97526 | 541-479-3865
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/1
/2
:4 :2
P
M
G2.00
TYPICAL ADA
STANDARDS -
EXISTING
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
DATE: Description
(C)
M
IN
WIDTH
DOOR
UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH
10" MAX.
M
IN
M
A X
10" MAX.
M
A X
>10" - 24" MAX.
M
A X
M
A X
CIRCULAR T-SHAPED OPTION
TURNING SPACE (EXISTING BUILDINGS) - SECTION 304
60" MIN.
OVERLAP OF KNEE AND TOE
M
IN
M
A X
M
A X
20" MAX. >20" - 25" MAX.
M
A X
UNOBSTRUCTED FWD REACH OBSTRUCTED HIGH FORWARD REACH
60" MIN.
M
IN
M
IN
M
IN
MIN.
12"
36" MIN.
MIN.
12" OVERLAP OF KNEE AND TOE
ARM
PULL SIDE PUSH SIDE
PUSH SIDE - DOOR PROVIDED
WITH BOTH CLOSER AND LATCH
M
IN
18" MIN.
M
IN
X
X
M
IN
12" MIN.
MANEUVERING CLEARANCES AT RECESSED DOORS (EXISTING BUILDINGS) - SECTION 404.2.3.5
FRONT APPROACHPOCKET OR HINGE APPROACHSTOP OR LATCH APPROACH
M
IN
M
IN
22" MIN.
M
IN
24" MIN.
MANEUVERING CLEARANCE AT SLIDING AND FOLDING DOORS (EXISTING BUILDINGS) - SECTION 404.2.3.3
FRONT APPROACH, PUSH SIDEHINGE APPROACH, PULL SIDE
HINGE APPROACH, PULL SIDEHINGE APPROACH, PUSH SIDELATCH APPROACH, PULL SIDE
(A) (B)
FRONT APPROACH, PULL SIDE
TWO DOORS OR GATES IN A SERIES (EXISTING BUILDINGS) - SECTION 404.2.5
MANEUVERING CLEARANCE AT SWINGING DOORS (EXISTING BUILDINGS) - SECTION 404.2.3
WIDTH
DOOR
M
IN
M
IN
18" MIN.
M
IN
*12" MIN.
*IF BOTH CLOSER
AND LATCH ARE
PROVIDED
36" MIN.
M
IN
M
IN
42" MIN.*4
M
IN
22" MIN.
*48" MIN. IF BOTH
CLOSER AND LATCH
ARE PROVIDED
*4
M
IN
24" MIN.
*54" MIN. IF CLOSER
IS PROVIDED
*4
M
IN
24" MIN.
*48" MIN. IF CLOSER
IS PROVIDED
60" MIN. 48" MIN.
WIDTH
DOOR
LATCH APPROACH, PUSH SIDE
FLOOR SURFACES - SECTION 302
NOTE:
CARPET OR CARPET TILE SHALL HAVE A LOOP,
TEXTURED LOOP, LEVEL CUT PILE, OR LEVEL
CUT/UNCUT PILE TEXTURE. THE PILE SHALL BE 1/2" MAX.
IN HEIGHT. EXPOSED EDGES OF CARPET SHALL BE
FASTENED TO THE FLOOR AND SHALL HAVE TRIM
ALONG THE ENTIRE LENGTH OF THE EXPOSED EDGE.
1/2" MAX.
OPENINGS IN FLOOR SURFACES - SECTION 302.3
1/2" MAX.
LONG DIMENSION
PERPENDICULAR
TO DIRECTION
OF TRAVEL
PREDOMINANT
DIRECTION OF TRAVEL
CHANGES IN LEVEL - SECTION 303
/4
M
A X
VERTICAL CHANGE IN LEVEL BEVELED CHANGE IN LEVEL (A)
/4
/2
M
A X
BEVELED CHANGE IN LEVEL (B)
/2
M
A X
NOTE:
CHANGES IN LEVEL GREATER THAN 1/2" IN HEIGHT
SHALL BE BY RAMP COMPLYING WITH SECTION 405 OR
BY A CURB CAMP COMPLYING WITH SECTION 406
PARALLEL
POSITION OF CLEAR FLOOR SPACE (EXISTING BUILDINGS) - SECTION 305.5
M
IN
48" MIN.
FORWARD
M
IN
30" MIN.
FORWARD APPROACHPARALLEL APPROACH
MANEUVERING CLEARANCE IN AN ALCOVE - SECTION 305.7
60" MIN.
X
36" MIN.
X
KNEE AND TOE CLEARANCE - SECTION 306
8" MIN.
M
IN
M
IN
11" MIN.
M
IN
25" MAX.
M
IN
25" MAX.
17" MIN.
6" MAX.
TOE CLEARANCE - ELEVATION
TOE CLEARANCE - PLAN
KNEE CLEARANCE - ELEVATION
KNEE CLEARANCE - PLAN
x
4" MAX.
X
4" MAX. 4" MAX.
POST
SIGN
M
A X
X > 12"
4" MAX. 4" MAX.
X < 12"
X > 12"
UNLIMITED
POST MOUNTED PROTRUDING OBJECTSLIMITS OF PROTRUDING OBJECTS
PROTRUDING OBJECTS - SECTION 307
NOTE:
ROTRUDING OBJECTS SHALL NOT REDUCE THE
CLEAR WIDTH REQUIRED FOR ACCESSIBLE ROUTES
REDUCED VERTICAL CLEARANCE
M
A X
X
24" MAX. 48" MIN. 24" MAX.
M
IN
M
IN
M
IN
M
IN
CLEAR WIDTH OF AN INTERIOR ACCESSIBLE ROUTE (EXISTING BUILDINGS) - SECTION 403.5
CLEAR WIDTH OF AN ACCESSIBLE ROUTE - INTERIOR
CLEAR WIDTH OF AN ACCESSIBLE ROUTE - EXTERIOR
24" MAX. 48" MIN. 24" MAX.
M
IN
M
IN
M
IN
M
IN
42" MIN.
X < 48"
42" MIN.
M
IN
36" MIN.
X < 48"
36" MIN.
CLEAR WIDTH AT 180-DEGREE TURN
OPTION 2
CLEAR WIDTH AT 180-DEGREE TURN
OPTION 1
M
IN
38" MIN.
60" MIN.
M
IN
M
IN
PASSING SPACE - 60"x60" OPTION
M
IN
PASSING SPACE - T-TURN OPTION
M
IN
M
IN
48" MIN. 36" MIN. 48" MIN.
T-TURN COMPLYING
WITH SECTION 304
CLEAR WIDTH AT 90-DEGREE TURN
REACH RANGES - SECTION 308
SLIDING DOOR
HINGED DOOR
32" MIN.
32" MIN.
CLEAR WIDTH OF DOORWAYS - SECTION 404.2
32" MIN.
FOLDING DOOR DOORWAYS WITHIN DOORS
36" MIN.
60" MIN. 60" MIN.
LANDING RAMP RUN LANDING
AT LEAST AS WIDE
AS RAMP RUN
60" MIN.
LANDING
M
IN
RAMP
RUN
RAMP
RUN
RAMPS - SECTION 405 RAMP EDGE PROTECTION - SECTION 405.9
RAMP
LANDING
10"
/2
M
A X
OR
10"
/2
M
A X
EDGE PROTECTION - LIMITED DROP-OFF EXCEPTION
12" MIN. 12" MIN.
EXTENDED FLOOR SURFACE
CURB
M
IN
C
U R
B
BARRIER
BARRIER PREVENTS PASSAGE
OF 4" SPHERE WITH ANY
PORTION WITHIN 4" OF FLOOR
NOTE:
1. RAMPS SHALL HAVE A RUNNING SLOPE
GREATER THAN 1:20 AND NOT STEEPER
THAN 1:12.
2. CROSS SLOPE OF RAMP RUNS SHALL
NOT BE STEEPER THAN 1:48.
3. HANDRAILS AND HANDRAIL SUPPORTS
THAT ARE PROVIDED ON THE RAMP RUN
SHALL NOT PROJECT INTO THE
REQUIRED CLEAR WIDTH OF THE RAMP
RUN.
4. THE RISE FOR ANY RAMP RUN SHALL BE
30" MAX.
5. RAMPS SHALL HAVE LANDINGS AT THE
BOTTOM AND TOP OF EACH RAMP RUN
6. LANDINGS SHALL HAVE A SLOPE NOT
STEEPER THAN 1:48.
7. CLEAR WIDTH OF LANDINGS SHALL BE AT
LEAST AS WIDE AS THE WIDEST RAMP
RUN LEADING TO THE LANDING.
8. RAMP RUNS WITH A RISE GREATER THAN
6" SHALL HAVE HANDRAILS.
NOTE:
EDGE PROTECTION SHALL BE PROVIDED ON
EACH SIDE OF RAMP RUNS AND AT EACH SIDE
OF RAMP LANDINGS
M
A X
B A
S E
M
IN
IC
C
A .1
E
X
IS
T
IN
G B
U
IL
D
IN
G
127 NW D Street, Grants Pass, Oregon 97526 | 541-479-3865
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/1
/2
:4 :2
P
M
G2.10
TYPICAL ADA
STANDARDS -
EXISTING
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
DATE: Description
CIVIL
COVER SHEET
C0.00
TRUE/PROJECT
NORTH
ASHLAND COMMUNITY CENTER
RENOVATION
ASHLAND, OR 97520
PROJECT INFORMATION VICINITY MAP SHEET INDEX
ABBREVIATIONS
APWA AMERICAN PUBLIC WORKS ASSOCIATION
ASTM AMERICAN STANDARD TEST METHOD
AWWA AMERICAN WATER WORKS ASSOCIATION
CONC CONCRETE
DEQ DEPARTMENT OF ENVIRONMENTAL QUALITY
DWG DRAWING
(e) EXISTING
EG EXISTING GRADE
FFE FINISHED FLOOR ELEVATION
FG FINISHED GRADE
GRD GROUND
IE INVERT ELEVATION
(N) NEW
NAVD NORTH AMERICAN VERTICAL DATUM
ROW RIGHT-OF-WAY
TBC TOP BACK OF CURB
BMP BEST MANAGEMENT PRACTICE
EPA ENVIRONMENTAL PROTECTION AGENCY
ESCP EROSION AND SEDIMENT CONTROL PLAN
LF LINEAL FEET
MAX MAXIMUM
MIN MINIMUM
TOS TOP OF STAIR
LOT INFORMATION:
SITE LOCATION: 59 WINBURN WAY
ASHLAND, OREGON 97520
TAX MAP: T39S-R01E-S09BC
TAX LOT: 2500
SITE ACREAGE: ±0.36 ACRES
ZONING: R-1-7.5 ASHLAND-RESIDENTIAL
PROJECT TEAM
OWNER
CITY OF ASHLAND PUBLIC WORKS
CONTACT: JASON STRAIT, PE
51 WINBURN WAY
ASHLAND, OR 97520
(541) 552-2419
ENGINEER OF RECORD
SYLAS E. ALLEN, PE
CONTACT: LUCAS GOWEY
ZCS ENGINEERING & ARCHITECTURE
45 HAWTHORNE STREET
MEDFORD, OR 97504
(541) 479-3865
ARCHITECT
ZACHARY A. STOKES, PE
CONTACT: JESSI RUSSELL
ZCS ENGINEERING & ARCHITECTURE
45 HAWTHORNE STREET
MEDFORD, OR, 97504
(541) 479-3865
SURVEYOR
JOHN PARIANI, PLS
PARIANI LAND SURVEYING
17 S. PLATT STREET, SUITE C
EAGLE POINT, OR 97524
(541) 890-1131
ATTENTION:
OREGON LAW REQUIRES YOU TO FOLLOW
RULES ADOPTED BY THE OREGON UTILITY
NOTIFICATION CENTER. THOSE RULES ARE SET
FORTH IN OAR 952-001-0010 THROUGH
952-001-0090. YOU MAY OBTAIN COPIES OF THE
RULES BY CALLING THE CENTER. (NOTE: THE
TELEPHONE NUMBER FOR THE OREGON UTILITY
NOTIFICATION CENTER IS (503 232-1987).
SITE PLAN
ASHLAND
COMMUNITY
CENTER
WINBURN WAY
C0.00 CIVIL COVER SHEET
C0.01 EROSION AND SEDIMENT CONTROL NOTES
C1.00 EXISTING CONDITIONS AND DEMOLITION PLAN
C2.00 SITE IMPROVEMENT PLAN
C3.00 PRIVATE CIVIL DETAILS
C4.00 AGENCY STANDARD DETAILS
M/E MATCH EXISTING
CIVIL LEGEND
SYMBOLS (EXISTING):
SYMBOLS (NEW):
HATCHES & LINE TYPES:
NEW CONCRETE PAVEMENT
GRADE SPOT ELEVATION
GRADING SLOPE2.0%
ac 1902.1 ac 1902.1
GRADE SPOT ELEVATION(e) ac 1902.1
(e) ac 1902.1
BUILDING COLUMN
IRRIGATION VALVE
WATER METER
HOSE BIB/YARD HYDRANT
SITE LIGHT
EXISTING POWER - BURIEDP
EXISTING NATURAL GASG
EXISTING WATERW
EXISTING SURFACE CONTOUR - MAJOR
EXISTING SURFACE CONTOUR - MINOR
POWER METER
TELEPHONE/COMMUNICATIONS RISER
EXISTING TELEPHONE - BURIEDTEL
SD EXISTING STORM SEWER
CATCH BASIN
POWER TRANSFORMER
CONCRETE RAMP
PROPERTY LINE
UTILITY STATEMENT:
EXISTING UNDERGROUND UTILITIES ILLUSTRATED IN THESE PLANS ARE
APPROXIMATED BASED ON MAPS OBTAINED FROM THE CITY OF ASHLAND
PUBLIC WORKS FILES, OR HAVE BEEN LOCATED BY A UTILITY LOCATE
COMPANY. LAYOUT INDICATED IS NOT TO BE RELIED ON AS BEING EXACT
OR COMPLETE. ALL LINES WITHIN PROJECTED WORK ZONE SHALL BE FIELD
VERIFIED AS REQUIRED PRIOR TO CONSTRUCTION.
EROSION CONTROL NOTE:
THIS EROSION AND SEDIMENT CONTROL PLAN MUST BE IMPLEMENTED
PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES. THE
INFORMATION CONTAINED WITHIN THE REFERENCED DRAWINGS SHALL BE
CONSIDERED A MINIMUM AND SHALL BE MODIFIED AS REQUIRED BY THE
CONTRACTOR AND INSPECTOR, TO CONTAIN ALL SEDIMENT ON SITE.
SPECIAL ATTENTION SHALL BE TAKEN AT ALL EXISTING STORM DRAIN
CATCH BASINS AND STORM DRAIN CHANNELS AS TO ELIMINATE ANY
SEDIMENT TRANSFER INTO THE EXISTING PUBLIC STORM DRAIN SYSTEM.
GENERAL CIVIL NOTES:
1. ALL WORK AND MATERIALS SHALL CONFORM TO THE 2021 OREGON
STANDARD SPECIFICATIONS FOR CONSTRUCTION, CURRENT OREGON
PLUMBING SPECIALTY CODE, AND ALL APPLICABLE STATE, CITY, AND
COUNTY REGULATIONS AND STANDARDS. CONTACT ENGINEER FOR
DIRECTIVE IN THE EVENT OF CONFLICTING STANDARDS.
2. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY SHALL BE COORDINATED
WITH THE CITY OF ASHLAND INSPECTOR AND SHALL CONFORM TO THAT
AGENCY'S CURRENT ENGINEERING STANDARD SPECIFICATIONS AND
DETAILS.
3. THE GENERAL CONTRACTOR AND ALL THEIR AFFILIATES SHALL VERIFY
ALL DIMENSIONS, ELEVATIONS, AND LOCATIONS PRIOR TO
CONSTRUCTION. IMMEDIATELY NOTIFY ENGINEER OF ANY
DISCREPANCIES.
4. ALL CONSTRUCTION STAKING, GRADE SURVEYING, AND HORIZONTAL
LAYOUT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR AND
SHALL BE PERFORMED BY A PROFESSIONAL LAND SURVEYOR LICENSED
IN THE STATE OF OREGON; COORDINATE WITH ENGINEER PRIOR TO
CONSTRUCTION.
5. ALL EXISTING UTILITIES IDENTIFIED IN THIS PLAN SET ARE NOT
INTENDED TO BE EXACT OR COMPLETE. IT SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL UTILITIES AND
PROTECT AS REQUIRED DURING THE COURSE OF CONSTRUCTION.
CALL THE "OREGON UTILITY NOTIFICATION CENTER" AT 1-800-332-2344
TO LOCATE EXISTING UTILITIES, 48 HOURS BEFORE DIGGING.
6. CONTRACTOR SHALL NOTIFY ALL APPLICABLE REGULATORY AGENCIES
AND UTILITY COMPANIES 48 HOURS PRIOR TO BEGINNING WORK.
7. ALL BASE ROCK PLACED IN UTILITY TRENCHES SHALL CONFORM TO THE
2021 OREGON STANDARD SPECIFICATIONS FOR CONSTRUCTION.
8. ALL UTILITY SERVICES SHALL BE INSTALLED PER THE RESPECTIVE
UTILITY CODES AND STANDARDS.
9. ALL UTILITIES SHALL HAVE A MINIMUM COVER AS IDENTIFIED IN THE
PLAN SET OR AS OTHERWISE SPECIFIED BY THE RESPECTIVE UTILITY
COMPANY.
10. ALL SERVICES SHALL BE ADEQUATELY MARKED AS TO IDENTIFY THE
SIZE, TYPE, AND DEPTH OF THE SERVICE. CONTRACTOR TO PROVIDE
LOCATE WIRE/TAPE AS REQUIRED BY THE APPLICABLE AGENCIES.
11. ALL UNDERGROUND UTILITIES AND SERVICE LATERALS SHALL BE
INSTALLED PRIOR TO CONSTRUCTION OF CURBS AND GUTTERS.
CONTRACTOR SHALL STAMP CURBS OR SIDEWALKS (AS APPLICABLE)
TO MARK THE LOCATIONS OF ALL SERVICE LINES (S - SANITARY, W -
WATER, D - STORM DRAIN, G - GAS).
12. ALL SERVICES AND SLEEVES SHALL BE PLUGGED AS REQUIRED TO
ENSURE THAT NO FOREIGN MATERIALS ENTER THE LINE.
13. CONTRACTOR SHALL PROVIDE THE ENGINEER WITH AN AS-BUILT
DRAWING OF ALL UTILITY SERVICE INSTALLATIONS INCLUDING THE
SERVICE SIZE, TYPE, DEPTH OF MAIN, TYPE OF CONNECTION AT MAIN,
INSTALLATION DATE, LOCATION, AND SKETCH (AS APPLICABLE).
14. CONTRACTOR SHALL OBTAIN ALL APPLICABLE PERMITS PRIOR TO
COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES. COORDINATE
WITH THE ENGINEER PRIOR TO CONSTRUCTION TO IDENTIFY PERMIT
REQUIREMENTS.
15. CONTRACTOR SHALL PROVIDE ENGINEER WITH SHOP DRAWING
SUBMITTALS ON ALL PERMANENTLY INSTALLED MANUFACTURED ITEMS.
16. STORM COLLECTION SYSTEM IS DESIGNED FOR WATER TIGHT
COMPONENTS.
17. ALL STORM PIPE IDENTIFIED AS 'PVC' SHALL BE ASTM D 3034 - SDR 35.
ALL STORM PIPE IDENTIFIED AS 'PERF' SHALL BE ASTM D 3034 WITH
3-WAY DIRECTIONAL PERFORATIONS.
18. ALL STORM COLLECTION SYSTEM CONNECTIONS AND COMPONENTS
SHALL CONFORM TO PIPE MANUFACTURER REQUIREMENTS.
CONTRACTOR TO COORDINATE FINAL STORM SYSTEM LAYOUT WITH
ENGINEER AND STORM SYSTEM SUPPLIER PRIOR AT TIME OF
CONSTRUCTION. STORM SYSTEM COMPONENT SHOP DRAWINGS SHALL
BE PROVIDED FOR ENGINEER'S REVIEW PRIOR TO CONSTRUCTION.
19. ALL UNDERGROUND PIPING, CONDUIT AND OTHER UTILITIES SHALL BE
INSTALLED PER ZCS DETAIL 8 ON SHEET C3.00 (OR AS OTHERWISE
SPECIFIED BY PIPE MANUFACTURER). NOTIFY ENGINEER IN EVENT OF
DISCREPANCIES.
20. ALL TEMPORARY PROTECTION AND DIRECTION OF TRAFFIC SHALL BE
BY THE CONTRACTOR AND CONFORM WITH BOTH THE MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES AND THE ODOT MANUAL ON
SHORT TERM TRAFFIC CONTROL (AS APPLICABLE).
21. HOLD SUB-GRADE ELEVATIONS DOWN 6" WITHIN LANDSCAPE AREAS
RECEIVING GROUND COVER AND/OR LAWN. REFER TO LANDSCAPE
PLANS FOR ADDITIONAL INFORMATION PERTAINING TO TOP SOIL
REQUIREMENTS, SEE LANDSCAPE NOTES FOR MORE DETAILS.
22. SEE PLAN SET FOR ADDITIONAL INFORMATION.
RESTORATION STATEMENT:
CONTRACTOR SHALL RESTORE BACK TO ORIGINAL CONDITION, PRIOR TO
CONTRACT COMPLETION, ALL DISTURBED SURFACES IMPACTED DURING
CONSTRUCTION. THIS INCLUDES, BUT IS NOT LIMITED TO, CONSTRUCTION
ACCESS, SIDEWALKS, CURBS, ASPHALT, LAWN AND LANDSCAPE AREAS, ETC.
DISTURBED AREAS TO BE GRADED SMOOTH AND ADEQUATELY SLOPED TO
DRAIN. AREA SHALL BE CLEAN AND FINISH GRADED BEFORE FINAL
DEMOBILIZATION. COORDINATE WITH ENGINEER AND OWNER AT THE TIME
OF PROJECT CONSTRUCTION COMPLETION.
SPECIAL CONCRETE NOTES:
THE FOLLOWING NOTES APPLY TO ALL PROJECT CONCRETE. CERTAIN
NOTES MAY NOT BE APPLICABLE. CONTACT THE ENGINEER OF RECORD
FOR CLARIFICATION AS REQUIRED:
1. ALL FLATWORK CONCRETE TO BE f'c = 3,500 PSI UNLESS NOTED OTHERWISE. ALL RETAINING WALL CONCRETE TO BE f'c = 4,000 PSI
UNLESS NOTED OTHERWISE. PROVIDE STANDARD CONCRETE TESTING
PUCKS FROM CONCRETE SUPPLIER.
2. ALL CONCRETE TO HAVE 6% (±1%) AIR ENTRAINMENT AND 4" SLUMP.
3. PERFORM WORK IN ACCORDANCE WITH ACI 301 AND ACI 318. FOLLOW
RECOMMENDATIONS OF ACI 305R WHEN CONCRETING DURING HOT
WEATHER AND ACI 306R WHEN CONCRETING DURING COLD WEATHER.
PLACE CONCRETE IN ACCORDANCE WITH ACI 304R. ENSURE
REINFORCEMENT, INSERTS, EMBEDDED PARTS, FORMED JOINTS ARE
NOT DISTURBED DURING CONCRETE PLACEMENT. PLACE CONCRETE
CONTINUOUSLY OVER THE FULL WIDTH OF THE PANEL AND BETWEEN
PREDETERMINED CONSTRUCTION JOINTS
4. ALL CONCRETE SHALL BE PLACED OVER 4" MINIMUM LAYER (UNLESS
NOTED OTHERWISE) OF APPROVED 3/4" MINUS ODOT SPEC CRUSHED
ROCK COMPACTED TO 95% AASHTO T-99 OVER APPROVED COMPACTED
(ASTM D698) STRUCTURAL FILL AS REQUIRED FOR GRADE OVER FIRM,
UNDISTURBED, NON-ORGANIC NATIVE MATERIAL. THE EXISTING SITE
SHALL BE CLEARED AND GRUBBED OF ALL ORGANIC AND/OR
EXPANSIVE MATERIAL PRIOR TO STRUCTURAL FILL IMPORT
5. ALL BACKFILL SHALL BE NON-ORGANIC, NON-EXPANSIVE GRANULAR
MATERIAL COMPACTED TO 95% PROCTOR
6. REINFORCING STEEL SHALL CONFORM TO ASTM A 615/A 615M GRADE 60
(420); DEFORMED BILLET STEEL BARS; UNFINISHED FINISH. STEEL
WELDED WIRE REINFORCEMENT SHALL BE PLAIN TYPE, ASTM A 185/A
185M; IN FLAT SHEETS; UNFINISHED. DOWELS SHALL CONFORM TO
ASTM A 615/A 615M GRADE 40 (280); DEFORMED BILLET STEEL BARS;
UNFINISHED FINISH. ALL TIE WIRE SHALL BE A MINIMUM OF #16
ANNEALED STEEL.
7. PLACE AND SECURE FORMS TO CORRECT LOCATION, DIMENSION,
PROFILE, AND GRADIENT. ASSEMBLE FORMWORK TO PERMIT EASY
STRIPPING AND DISMANTLING WITHOUT DAMAGING CONCRETE. PLACE
JOINT FILLER VERTICAL IN POSITION, IN STRAIGHT LINES. SECURE TO
FORMWORK DURING CONCRETE PLACEMENT. HOLD TOP OF
PRE-MOLDED JOINT FILLER DOWN 1/2" AND SEAL UPPER 3/8" WITH
APPROVED JOINT SEAL MATERIAL.
8. RETAINING WALLS TO BE AT MINIMUM 80% DESIGN STRENGTH AND 7
DAYS CURE PRIOR TO ANY BACKFILL PLACEMENT.
9. NO HORIZONTAL CONSTRUCTION JOINTS PERMITTED
10. MAXIMUM VARIATION OF SURFACE FLATNESS SHALL NOT EXCEED 1/4
INCH IN 10 FT AND MAXIMUM VARIATION FROM TRUE POSITION SHALL
NOT EXCEED 1/4 INCH
11. IMMEDIATELY AFTER PLACEMENT, PROTECT PAVEMENT FROM
PREMATURE DRYING, EXCESSIVE HOT OR COLD TEMPERATURES, AND
MECHANICAL INJURY. DO NOT PERMIT PEDESTRIAN TRAFFIC OVER
PAVEMENT FOR 7 DAYS MINIMUM AFTER FINISHING.
12. FINISH AS FOLLOWS:
A. SIDEWALK PAVING: LIGHT BROOM, TEXTURE PERPENDICULAR TO
DIRECTION OF TRAVEL WITH TROWELED AND RADIUSED EDGE 1/2
INCH RADIUS
B. RETAINING WALLS: SMOOTH RUBBED FINISH. WET CONCRETE AND
RUB WITH CARBORUNDUM BRICK OR OTHER ABRASIVE, NOT MORE
THAN 24 HOURS AFTER FORM REMOVAL. REPAIR/PLUG SURFACE
DEFECTS, INCLUDING TIE HOLES, IMMEDIATELY AFTER REMOVING
FORM WORK.
C. PLACE CURING COMPOUND ON EXPOSED CONCRETE SURFACES
IMMEDIATELY AFTER FINISHING. APPLY IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS.
SITE PREPARATION NOTES:
CLEARING AND GRUBBING -
1. ALL AREAS BELOW WALKWAYS SHALL BE CLEARED AND GRUBBED OF
ALL PAVEMENT, FOREIGN MATTER, DEBRIS, ORGANIC AND DISTURBED
MATERIAL, (U.N.O.) STRIPPING DEPTHS WILL VARY DEPENDING ON
LOCATION AND PAVEMENT SECTION REQUIREMENTS. ALL EXPOSED
MATERIAL SHALL BE MOISTURE CONDITIONED TO WITHIN 2% OF
OPTIMUM PRIOR TO PLACEMENT OF FILL MATERIAL DESCRIBED BELOW.
2. ALL CLEARED AND GRUBBED MATERIAL NOT UTILIZED FOR THE
PROJECT SHALL BE REMOVED FROM THE CONSTRUCTION SITE.
CONTRACTOR SHALL COORDINATE APPROVED DISPOSAL LOCATION.
3. ALL AREAS WITH ABANDONED UTILITY LINES, STORM DRAINS,
UNDERGROUND TANKS, ETC. WHICH PROVIDE VOID SPACE BENEATH
THE SURFACE SHALL BE LOCATED AND REMOVED PRIOR TO GRADING
ACTIVITIES.
4. ALL HOLES, DEPRESSIONS, AND UNDISTURBED NATIVE MATERIAL SHALL
BE CLEARED OF ALL LOOSE AND ORGANIC MATERIAL PRIOR TO
BACKFILLING WITH APPROVED STRUCTURAL FILL.
5. AFTER CLEARING THE ABOVE MENTIONED AREAS, ALL EXPOSED
SUB-GRADE SHALL BE PROOF ROLLED WITH A LOADED DUMP TRUCK OR
HEAVY NON-VIBRATORY ROLLER. SOILS SHALL BE REMOVED AND
RECOMPACTED OR REPLACED WITH APPROVED IMPORTED
STRUCTURAL FILL IF THEY DO NOT DEMONSTRATE A FIRM, UNYIELDING
CONDITION. CIVIL ENGINEER OF RECORD SHALL APPROVE SUB-GRADE
SURFACE PRIOR TO STRUCTURAL FILL IMPORT EXPLAINED BELOW.
STRUCTURAL FILL PLACEMENT AND COMPACTION -
6. APPROVED STRUCTURAL FILL SHALL BE IMPORTED AND PLACED
BENEATH AREAS RECEIVING CONCRETE PAVEMENT.
7. STRUCTURAL FILL MATERIALS SHALL BE APPROVED BY THE CIVIL
ENGINEER OF RECORD PRIOR TO IMPORTING. ALL FILL SHALL BE FREE
OF ORGANIC AND EXPANSIVE CLAY MATERIAL. ALL BASE ROCK SHALL
CONFORM TO THE SPECIFICATIONS IDENTIFIED IN THE PLAN SET.
8. STRUCTURAL FILL PLACEMENT LIFTS TO BE DETERMINED BY THE CIVIL
ENGINEER OF RECORD BASED ON MATERIAL PROPERTIES AND TYPE OF
COMPACTION EQUIPMENT USED. BASE ROCK PLACEMENT LIFTS SHALL
NOT EXCEED 8". EACH LIFT SHALL BE NEARLY EQUAL IN THICKNESS AND
COMPACTED TO A MINIMUM OF 95% OF ASTM D698. FILLS SHALL BE
PLACED AT OR SLIGHTLY ABOVE THEIR OPTIMUM MOISTURE CONTENT.
GENERAL CIVIL NOTES
CATCH BASIN
NEW STORM SEWERSD
PIONEER HALL
BUILDING
STORM DRAIN CLEANOUT
TREE - CONIFER
SHRUB
LIMITS OF WORK
EXISTING IRRIGATIONIRR
EXISTING FENCEX
NEW LANDSCAPING
ROOF DRAIN DOWNSPOUT
ROOF DRAIN DOWNSPOUT
BOS BOTTOM OF STAIR
SW SIDEWALK
TOW TOP OF WALL
TYP TYPICAL
CLEANOUT RISER TO GRADE
FLAGPOLE
SS EXISTING SANITARY SEWER
TOC TIME OF CONSTRUCTION
GUT GUTTER
CB CATCH BASIN
EXISTING FENCEX
EA EACH
PROJECT NO:
DRAWN:
CHECKED:
DATE:
CITY OF ASHLAND
59 WINBURN WAY
ASHLAND, OR 97520
ASHLAND
COMMUNITY
CENTER
RENOVATION
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
BI
D
P
ER
M
IT
03-13-24
MKW, LGG
CMW
M-0298-22
REVISION ID: DATE:
O N
E
IN
C H
E Q
U
AL
S
FU
LL
S
C
AL
EROSION AND
SEDIMENT CONTROL
NOTES
C0.01
CONCRETE MANAGEMENT:
CONCRETE TRUCKS AND TRANSFER CHUTES SHALL BE WASHED-OUT ON-SITE
UTILIZING A CONCRETE WASHOUT TO COLLECT ALL WASH WATER AND
CONCRETE WASTE. THE WASHOUT AREA WILL BE LOCATED AWAY FROM STORM
DRAINS, OPEN DITCHES OR WATER BODIES. SIGNS WILL BE POSTED
THROUGHOUT THE JOBSITE, DIRECTING CREWS AND CONCRETE TRUCKS TO
CONCRETE WASHOUTS. UPON COMPLETION OF THE CONCRETE WORK, THE
CONTRACTOR SHALL BREAK UP, REMOVE, AND HAUL AWAY OR REUSE ON SITE
SOLID CONCRETE THAT HAS ACCUMULATED IN THE WASHOUT.
CONSTRUCTION SPECIFICATIONS:
MATERIAL USE:
· INSTALL STORM DRAIN PROTECTION AT ANY DOWN-GRADIENT INLETS THAT
MAY BE IMPACTED BY THE ACTIVITY. SEE THE BMP ON “STORM DRAIN INLET
PROTECTION.”
· DO NOT PLACE CONCRETE DURING RAIN (PRECIPITATION THAT IS
SUFFICIENT TO CAUSE LOCAL RUNOFF) OR WITHIN 18 HOURS OF
FORECASTED RAIN.
· PLACE STOPPERS ON CONCRETE TRUCK CHUTES DURING TRAVEL ONSITE
TO MANAGE POTENTIAL DRIBBLING OF CONCRETE MATERIAL.
· MINIMIZE AMOUNT OF CURING COMPOUND AND FORM OIL USED AND DO
NOT OVERSPRAY ONTO A NON-TARGET SURFACE.
· SANDBLASTING: USE SHROUDS WHERE NECESSARY TO CONTAIN WASTE
FROM SANDBLASTING. CONDUCT WORK IN ACCORDANCE WITH APPLICABLE
AIR QUALITY STANDARDS. COLLECTED DEBRIS FOR PROPER DISPOSAL
ASAP AND PRIOR TO RAIN EVENTS.
· MINIMIZE THE AMOUNT OF WATER USED DURING CORING/DRILLING OR SAW
CUTTING. DURING WET CORING OR SAW CUTTING, USE A SHOVEL OR WET
VACUUM TO LIFT THE COOLING WATER / SLURRY FROM THE PAVEMENT.
ADDITIONALLY, IF WET VACUUMING IS NOT ADEQUATE TO CAPTURE
WASTEWATER FROM THE ACTIVITY, SAND BAG BARRIERS OR OTHER
CONTAINMENT SHALL BE USED.
· IF CONCRETE RESIDUE REMAINS AFTER DRYING, THE AREA SHALL BE
SWEPT UP AND RESIDUE REMOVED TO AVOID CONTACT WITH STORM
WATER OR ENTERING A STORM DRAIN OR WATER BODY VIA THE WIND. �
· THE SWEEPINGS SHALL BE COLLECTED AND RETURNED TO THE
AGGREGATE STOCKPILE OR DISPOSED IN THE TRASH AND NOT WASHED
INTO THE STREET OR STORM DRAIN.
· WASHING OF FRESH CONCRETE SHALL BE AVOIDED, UNLESS RUNOFF CAN
BE DRAINED TO A BERMED OR LEVEL AREA, AWAY FROM STORM DRAIN
INLETS AND CHANNELS.
· ACID WASHING OF CONCRETE SHALL BE MINIMIZED. WHERE REQUIRED,
ACID WASH SHALL BE DIRECTED INTO A COLLECTION AREA LINED WITH
VISQUEEN. RESIDUALS SHALL BE COLLECTED AND PROPERLY DISPOSED OF
AS HAZARDOUS WASTE.
· HANDLING OF WET CONCRETE, SUCH AS MOVING A PUMPER CHUTE OR
TRANSPORTING MATERIAL IN A WHEELBARROW FROM THE DELIVERY
TRUCK, MUST BE PERFORMED IN A CONTROLLED MANNER TO PREVENT
DRIPS AND SPILLS OUTSIDE THE TARGET POUR AREA. MINIMIZE WATER
USE.
· CONCRETE DRIPS, SPILLS, OVER POURS, AND EQUIPMENT RINSE WATER
LANDING ON RAIN-EXPOSED OUTSIDE OF ANY BMP DEVICE MUST BE
COLLECTED AND HAVE THE SURFACE CLEANED AND WASTE DISPOSED OF
PROPERLY PRIOR TO THE END OF THE WORKDAY OR BEFORE THE NEXT
RAIN EVENT. CONCRETE-LADEN EQUIPMENT IMPLEMENTS (E.G., CRANE
BUCKETS) MUST BE STORED ON TOP OF HEAVY MIL PLASTIC UNTIL DRY.
USED FORMS THAT ARE NOT IMMEDIATELY PLACED INTO A HAUL TRUCK
WHEN REMOVED FROM FOUNDATIONS MUST ALSO BE TEMPORARILY
STAGED OVER PLASTIC SHEETING OR AN EQUIVALENT UNTIL RINSED,
WIPED, OR DRIED OR UNTIL HAULED OFFSITE.
WASTE MANAGEMENT:
· DO NOT DISCHARGE CONCRETE RESIDUE OR PARTICULATE MATTER INTO
A STORM DRAIN INLET OR WATERCOURSE.
· EXCESS CONCRETE SHALL NOT BE DUMPED ON-SITE.
THE FOLLOWING OPTIONS SHALL BE USED FOR CONCRETE TRUCK CHUTE
AND/OR PUMP AND HOSE WASHOUT:
CONCRETE WASHOUTS: WASHOUT STATIONS CAN BE A PLASTIC LINED
TEMPORARY PIT OR BERMED AREA DESIGNED WITH SUFFICIENT VOLUME
TO COMPLETELY CONTAIN ALL LIQUID AND WASTE CONCRETE MATERIALS
PLUS ENOUGH CAPACITY FOR RAINWATER. THE DESIGNATED AREA SHALL
BE LOCATED AWAY FROM STORM DRAIN INLETS, OR WATERCOURSES.
NEW WASHOUTS SHALL BE CONSTRUCTED AS NEEDED TO PROVIDE
SUFFICIENT. WASHOUT CAPACITY ON-SITE. WASTES OTHER THAN
CONCRETE (I.E., TRASH, PAINT WASTES ETC.) SHALL NOT BE DISPOSED OF
IN THE WASHOUT.
INSPECTION AND MAINTENANCE:
· RESPONSIBLE PERSONNEL SHALL ENSURE THAT ALL CONCRETE TRUCK
DRIVERS ARE INSTRUCTED ABOUT PROJECT PRACTICES WHEN THE
TRUCKS ARRIVE ON SITE.
· CLEAN OUT DESIGNATED WASHOUT AREAS AS NEEDED OR AT A MINIMUM
WHEN THE WASHOUT IS 75 PERCENT FULL TO MAINTAIN SUFFICIENT
CAPACITY THROUGHOUT THE PROJECT DURATION.
· ANY DESIGNATED ONSITE WASHOUT AREAS SHALL BE CLEANED OUT AND
ALL DEBRIS REMOVED UPON PROJECT COMPLETION. DISPOSE OF
CONCRETE WASTE ACCORDING TO THE BMP ON “SOLID WASTE
MANAGEMENT.”
INSPECT ROUTINELY, WHEN APPLICABLE ACTIVITIES ARE UNDERWAY TO
ENSURE THAT CONCRETE WASHOUT DOES NOT OVERFLOW AND THAT
FREEBOARD IS ADEQUATE TO CONTAIN CONCRETE AND RAIN.
EROSION CONTROL
INSPECTION AND MAINTENANCE:
1. NEWLY SEEDED AREAS SHALL BE INSPECTED FREQUENTLY TO ENSURE
THE GRASS IS GROWING. PROVIDE TEMPORARY IRRIGATION AS REQUIRED
TO GERMINATE AND ESTABLISH SEED. SEE SEEDING REQUIREMENTS FOR
ADDITIONAL INFORMATION TYPICAL.
2. IF SEEDED AREAS ARE DAMAGED DUE TO RUNOFF, ADDITIONAL BMP's MAY
BE NEEDED. RE-SEED DAMAGED AREAS IMMEDIATELY. SEE SEEDING
REQUIREMENTS FOR ADDITIONAL INFORMATION TYPICAL.
3. REFER TO CURRENT OREGON/APWA STANDARD
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
SPILL PREVENTION AND CONTROL PROCEDURES:
CONSTRUCTION SPECIFICATIONS:
· THE CONTRACTOR SHALL PREPARE A SITE/PROJECT SPECIFIC SPILL
RESPONSE PLAN THAT IDENTIFIES THE TYPE AND LOCATION OF PRODUCTS
OR WASTES ON THE SITE WITH SPILL POTENTIAL, THE LOCATION OF SPILL
CLEANUP MATERIALS, STORM DRAINS OR SENSITIVE AREAS THAT REQUIRE
IMMEDIATE RESPONSE, PERSONNEL RESPONSIBLE FOR SPILL RESPONSE
AND NOTIFICATIONS, AND SPILL CLEANUP PROCEDURES.
· AVOIDING SPILLS AND LEAKS IS PREFERABLE TO CLEANING THEM UP
AFTER THEY OCCUR. HEAVY EQUIPMENT (E.G., BULLDOZERS AND OTHER
GRADING EQUIPMENT) AND VEHICLES SHOULD BE INSPECTED DAILY (OR AS
OFTEN AS POSSIBLE) FOR LEAKS AND SHOULD BE REPAIRED AS
NECESSARY. USE SECONDARY CONTAINMENT AND DRIP PANS FOR
VEHICLE FUELING, MAINTENANCE, AND STORAGE (SEE BMP FOR “VEHICLE
AND EQUIPMENT FUELING, MAINTENANCE, AND STORAGE.”
· DESPITE PRECAUTIONS, SPILLS MAY STILL OCCUR AT THE SITE. SPILLS (OF
LIQUID OR DRY MATERIALS) SHOULD NEVER BE CLEANED UP BY HOSING
OFF THE AREA. IN THE EVENT THAT SPILLS OCCUR THEY SHOULD BE
CONTROLLED AS FOLLOWS:
· ANY FUEL PRODUCTS, LUBRICATING FLUIDS, GREASE OR OTHER PRODUCTS
AND/OR WASTE RELEASED FROM VEHICLES, EQUIPMENT, OR OPERATIONS
SHALL BE COLLECTED AND DISPOSED OF IN ACCORDANCE WITH STATE,
FEDERAL AND LOCAL LAWS.
· IF THE SPILL HAS OCCURRED DURING A RAIN EVENT, THE AREA WILL BE
COVERED AS QUICKLY AS POSSIBLE. THE SPILL WILL BE CLEANED UP AS
SOON AS POSSIBLE DURING OR AFTER CESSATION OF RAIN.
· SPILL CLEANUP MATERIALS WILL BE STORED NEAR POTENTIAL SPILL AREAS
(E.G., PAINTING, VEHICLE MAINTENANCE AREAS).
· MINOR SPILLS: MINOR SPILLS TYPICALLY INVOLVE SMALL QUANTITIES OF
OIL, GASOLINE, PAINT, ETC. THAT CAN BE CONTROLLED BY THE FIRST
RESPONDER AT THE DISCOVERY OF THE SPILL. CONTROL OF MINOR SPILLS
INVOLVES:
1. CONTAIN THE SPILL IMMEDIATELY.
2. RECOVER SPILLED MATERIALS (IF POSSIBLE).
3. CLEAN THE CONTAMINATED AREA AND DISPOSE OF CONTAMINATED
MATERIALS.
MEDIUM-SIZED SPILLS:
· MEDIUM-SIZED SPILLS STILL CAN BE CONTROLLED BY THE FIRST
RESPONDER, ALONG WITH THE AID OF OTHER PERSONNEL SUCH AS
LABORERS, FOREMEN, ETC. THIS RESPONSE MAY REQUIRE THE CESSATION
OF OTHER ACTIVITIES. SPILLS SHOULD BE CLEANED UP IMMEDIATELY, AS
FOLLOWS:
1. NOTIFY THE PROJECT FOREMAN IMMEDIATELY. THE
FOREMAN/SUPERINTENDENT IS RESPONSIBLE FOR ANY NECESSARY
NOTIFICATIONS (FIRE DEPARTMENT ETC.).
2. CONTAIN THE SPREAD OF THE SPILL (USING SAND BAGS OR OTHER
BARRIERS) IMMEDIATELY.
3. IF THE SPILL HAS OCCURRED ON A PAVED OR IMPERMEABLE SURFACE,
CLEAN IT UP USING DRY METHODS (ABSORBENT MATERIALS, AT LITTER,
AND/OR RAGS). CONTAIN THE SPILL BY ENCIRCLING IT WITH
ABSORBENT MATERIALS.
4. IF THE SPILL HAS OCCURRED ON AN UNPAVED OR PERMEABLE
SURFACE, IMMEDIATELY CONTAIN THE SPILL BY CONSTRUCTING AN
EARTHEN DIKE. DIG UP AND PROPERLY DISPOSE OF CONTAMINATED
SOIL.
5. IF THE SPILL HAS OCCURRED DURING A RAIN EVENT, COVER/CONTAIN
THE AREA IF POSSIBLE.
SIGNIFICANT/HAZARDOUS SPILLS:
· FOR LARGE SPILLS OR SPILLS…