Attachment 2 to Addendum 3 - Revised Community Center Drawings.pdf
PDF 14 MB Posted
- Attached to
- Community Center and Pioneer Hall Rehabilitation
- Solicitation number
- S-KA0010-00009824
- Issued by
- Jackson County, Amity City, Oregon
About this file
Attachment 2 to Addendum 3 is related to the state and local contracting opportunity for the rehabilitation of the Community Center and Pioneer Hall facilities in Jackson County, Oregon. This project, managed by the City of Ashland on behalf of Jackson County, involves selective demolition, structural upgrades, mechanical/electrical/plumbing work, interior and exterior renovations, ADA improvements, and hazardous material abatement. The project specifications cover a wide range of construction trade work, including concrete, metals, wood and plastic-laminate construction, thermal and moisture protection, windows and doors, finishes, and utilities. The mandatory pre-bid meeting is scheduled for April 9, 2024, and bids are due by 2:00 pm PST on April 30, 2024.
The solicitation documents do not specify any set-aside designations or restrictions on the types of organizations that can respond. The incumbent contractor and current contract value are also not provided. The project budget and funding sources are also not detailed in the available information. Interested parties should thoroughly review the bid and permit drawings, specifications, and other provided documentation to fully understand the scope of work, response requirements, and evaluation criteria for this state and local contracting opportunity.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A101
SIM
A101
A101 1R e f
XX
Name Elevation
N
Room name
150 SF
A101
SIM
View Name A1.1
1/4" = 1'-0"
ROOM NAME
ROOM NUMBER
ROOM AREA
KEYNOTE TAG
REVISION SET TAG
1i
DOOR NUMBER
FINISH TYPE
WINDOW/GLAZING
TAG
LEVEL HEAD
SHEET REFERENCE
ELEVATION REFERENCE
ELEVATION SYMBOL
SHEET REFERENCE
INTERIOR ELEVATION
REFERENCE
INTERIOR
ELEVATION SYMBOL
SHEET REFERENCE
INTERIOR ELEVATION
REFERENCE
BUILDING & WALL
SECTION
SHEET REFERENCE
DRAWING
REFERENCE
DETAIL
REFERENCE
A101
SIM
SHEET REFERENCE
DRAWING
REFERENCE
ENLARGED
PLAN
DESIGNATED AREA
PROJECT NORTH
SHEET REFERENCE
VIEW TITLE
DRAWING SCALE
WALL TYPE TAG
STRUCTURAL
KEYNOTE TAG
CEILING TAG
FLOOR
TRANSITION TAG
CENTER LINE
DELTA w// CURRENT
REVISION NUMBER
PREVIOUS REVISION
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
NOTES
ACT
8'-0"
Remarks
EX#
EX#
ME#
ME#
XX#
XX# FLOOR FINISH
BASE FINISH
ADDITIONAL NOTES
WALL FINISHES
FINISH TAG
TR#
A101
Ref
R e f
R e f
Ref
SHEET REFERENCE
DRAWING
REFERENCE
PHOTO REFERENCE
FINISH TAG
XX
DRAWING NUMBER
1i PLUMBING FIXTURE TAG
1 Ref
R e f
1 Ref
R e f
X
ADDITIONAL KEYNOTE#
PROJECT LOCATION:
74 WINBURN WAY,
ASHLAND, OR 97520
PIONEER HALL
ASHLAND COMMUNITY CENTER - HATCH
INDICATES AREA OF WORK
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESSIONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7, 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/8
/2
:5
:3
A M
A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
G0.00
COVER SHEET
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
ASHLAND COMMUNITY CENTER RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
100% CONSTRUCTION DOCUMENTS | BID & PERMIT
N
SHEET INDEX
A.B. ANCHOR BOLT
A.C. ASPHALT CONCRETE
A.C.B. ACOUSTICAL BOARD
ACI AMERICAN CONCRETE
INSTITUTE
A.C.P. ACOUSTICAL PANEL
A.C.T. ACOUSTICAL CEILING
TILE
ADD'L. ADDITIONAL
A.D. AREA DRAIN
ADJ. ADJUSTABLE
A.F. ACCESS FLOORING
AGGR. AGGREGATE
A.F.F. ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
ARCH. ARCHITECT
ASCE AMERICAN SOCIETY OF
CIVIL ENGINEERS
ASTM AMERICAN SOCIETY FOR
TESTING AND MATERIALS
AWS AMERICAN WELDING
SOCIETY
BD. BOARD
BITUM. BITUMINOUS
BKP. BACKING PLATE
BM. BEAM
BOT./B.O. BOTTOM/BOTTOM OF
C.B. CATCH BASIN
CEM. CEMENT
CER. CERAMIC
C.G. CORNER GUARD
C.I. CAST IRON
C.J. CONTROL JOINT
CJP COMPLETE JOINT
PENETRATION
CL CENTERLINE
CLG. CEILING
CLKG. CAULKING
CLO. CLOSET
CLR. CLEAR
CMU CONCRETE MASONRY
UNIT
C.O. CASED OPENING
CONC. CONCRETE
CONN. CONNECTION
CONST. CONSTRUCTION
CORR. CORRIDOR
CPT. CARPET
CTSK. COUNTERSUNK
C.T. CERAMIC TILE
CTR. CENTER
DBA DEFORMED BAR
ANCHOR
D.F. DRINKING FOUNTAIN
D.L. DEAD LOAD
DET. DETAIL
DIA., ⌀ DIAMETER
DISP. DISPENSER
DR. DOOR
DWG. DRAWING
DWR. DRAWER
D.S. DOWNSPOUT
D.S.P. DRY STANDPIPE
(E) EXISTING
E.J. EXPANSION JOINT
ELEC. ELECTRICAL
EL. ELEVATION
EQ. EQUAL
EXPO. EXPOSED
EXP. EXPANSION
EXT. EXTERIOR
F.A. FIRE ALARM
FB. FLAT BAR
F.D. FLOOR DRAIN
FDN. FOUNDATION
FE FIRE EXTINGUISHER
F.H. FLAT HEAD
FIN. FINISH
FLR. FLOOR
F.O.C FACE OF CONCRETE
F.O.F FACE OF FINISH
F.O.S. FACE OF STUDS
F.S. FULL SIZE
FT. FOOT
FTG. FOOTING
FUT. FUTURE
Ga. GAUGE
GALV. GALVANIZED
GL GRID LINE
GLB GLULAM BEAM
G.B. GRAB BAR
GND. GROUND
GYP. GYPSUM
G.W.B. GYPSUM WALL BOARD
H.B. HOSE BIBB
H.C. HOLLOW CORE
H.M. HOLLOW METAL
HORIZ. HORIZONTAL
HSS HOLLOW STRUCTURAL
STEEL
IBC INTERNATIONAL
BUILDING CODE
I.D. INSIDE DIAMETER
IN. INCH
INT. INTERIOR
J.B. JUNCTION BOX
J.O.H. JAMB OPENING HEIGHT
J.O.W. JAMB WIDTH
JT. JOINT
K KIPS
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
LAM. LAMINATE
LB. POUND
L.L. LIVE LOAD
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LOC. LOCATION
LONG. LONGITUDINAL
L.P. LOW POINT
LVF LOW VELOCITY FASTENER
MAX. MAXIMUM
MBMA METAL BUILDING
MANUFACTURERS
ASSOCIATION
M.C. MEDICINE CABINET
M.D.F. MEDIUM DENSITY
FIBERBOARD
M.D.O. MEDIUM DENSITY
OVERLAY
MECH. MECHANICAL
MEMB. MEMBRANE
MFR. MANUFACTURER
MH. MANHOLE
MIN. MINIMUM
MIR. MIRROR
MISC. MISCELLANEOUS
M.O. MASONRY OPENING
M.P. MIDPOINT
MPH MILES PER HOUR
M.S. MACHINE SCREW
MT MAGNETIC PARTICLE
TESTING
MTD. MOUNTED
MUL. MULLION
(N) NEW
N.I.C. NOT IN CONTRACT
NOM. NOMINAL
N.T.S. NOT TO SCALE
OBS. OBSCURE
o.c. ON CENTER
O.C.D. OVERHEAD COILING
DOOR
O.C.G OVERHEAD COILING
GRILLE
O.D. OUTSIDE DIAMETER
O.F.C.I. OWNER FURNISHED
CONTRACTOR
INSTALLED
O.F.D. OVERFLOW DRAIN
O.F.O.I. OWNER FURNISHED
OWNER INSTALLED
OH. OPPOSITE HAND
OPP. OPPOSITE
OWJ OPEN WEB JOIST
-GENERAL-
G0.00 COVER SHEET
G1.00 CODE PLAN - COMMUNITY CENTER
G2.00 TYPICAL ADA STANDARDS - EXISTING
G2.10 TYPICAL ADA STANDARDS - EXISTING
-ARCHITECTURAL-
A0.00 ASSEMBLIES AND DOOR SCHEDULES
A0.10 FINISH SCHEDULES
A1.00 FLOOR PLAN
A1.10 ROOF PLAN
A2.00 REFLECTED CEILING PLAN
A3.00 FINISH FLOOR PLAN
A4.00 EXTERIOR ELEVATIONS
A4.10 EXTERIOR ELEVATIONS
A5.00 BUILDING SECTIONS
A5.10 WALL SECTIONS
A6.00 STAIRS AND RAMP SECTIONS
A7.00 ENLARGED PLANS & INTERIOR ELEVATIONS
A7.10 ENLARGED PLANS & INTERIOR ELEVATIONS
A7.11 ENLARGED PLANS & INTERIOR ELEVATIONS
A8.00 EXTERIOR DETAILS
A8.10 EXTERIOR DETAILS
A9.00 INTERIOR DETAILS
OWNER:
CONTACT: JASON STRAIGHT PM
CITY OF ASHLAND PUBLIC WORKS
51 WINBURN WAY
ASHLAND, OR 97520
T 541.552.2419
ARCHITECTURE:
STAMPING REGISTRANT: ZACH STOKES, P.E.
CONTACT: JESSI RUSSELL, ARCHITECT
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
STRUCTURAL ENGINEERING:
ENGINEER OF RECORD: MATT SMITH P.E. S.E.
CONTACT: STEPHEN CHASE
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
CIVIL ENGINEERING:
ENGINEER OF RECORD: SYLAS ALLEN, P.E.
CONTACT: LUCAS GOWEY
ZCS ENGINEERING & ARCHITECTURE
127 NW D ST.
GRANTS PASS, OR 97526
T 541.479.3865
SURVEY:
CONTACT: JOHN R. PARIANI PLS
PARIANI LAND SURVEYING
17 S PLATT ST. SUITE C
EAGLE POINT, OR 97524
T 541.890.1131
GENERAL CONTRACTOR:
TBD
1. ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS
SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL
NOTIFY THE PROJECT TEAM OF ANY SIGNIFICANT
DISCREPANCIES FROM CONDITIONS SHOWN ON THE
DRAWINGS.
2. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
ALL CONSTRUCTION MEANS AND METHODS.
RESPONSIBILITY SHALL INCLUDE BUT NOT LIMITED TO
DEMOLITION AND CONSTRUCTION MEANS AND METHODS,
TECHNIQUES, SEQUENCING, AND SAFETY REQUIRED TO
COMPLETE CONSTRUCTION.
3. BEFORE STARTING A SECTION OF WORK THE
CONTRACTOR SHALL CAREFULLY EXAMINE PREPARATORY
WORK THAT HAS BEEN EXECUTED. ENSURE THAT WORK
AND ADJACENT RELATED WORK WILL FINISH TO PROPER
PLANES AND LEVELS.
4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING
ALL MATERIALS AND WORKMANSHIP IN ACCORDANCE
WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL
CODES.
5. CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL
CONTRACT DOCUMENTS, FIELD CONDITIONS, AND
DIMENSIONS FOR ACCURACY AND CONFIRMING THAT
WORK IS BUILDABLE AS SHOWN BEFORE PROCEEDING
WITH THE CONSTRUCTION. IF THERE ARE ANY QUESTIONS,
THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING A
CLARIFICATION FROM THE PROJECT TEAM BEFORE
PROCEEDING WITH THE WORK IN QUESTION OR RELATE
WORK.
6. THE CONTRACTOR SHALL NOT SCALE DRAWINGS. WRITTEN
DIMENSIONS SHALL ALWAYS GOVERN. CONTRACTOR
REQUIRING DIMENSIONS NOT NOTED SHALL ALWAYS
CONTACT THE PROJECT TEAM FOR SUCH INFORMATION
PRIOR TO PRECEDING WITH WORK RELATED TO THOSE
DIMENSIONS
7. THE CONTRACTOR SHALL PROTECT, PATCH, AND REPAIR
TO MATCH ANY WALLS, FLOORS, CEILINGS, AND/OR OTHER
SURFACES WHICH MAY BE DISTURBED DURING THE
INSTALLATION OF MECHANICAL, ELECTRICAL, PLUMBING
OR OTHER OWNER WORK.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING AND PATCHING REQUIRED FOR PROPER
INSTALLATION OF MATERIAL AND EQUIPMENT. PROVIDE
DEMOLITION AND PATCH/REPAIR IN ALL AREAS (WHETHER
SPECIFICALLY SHOWN OR NOT) TO ACCOMMODATE ALL
WORK.
9. IF THE CONTRACTOR ENCOUNTERS A CONDITION NOT
COVERED IN THE CONSTRUCTION DOCUMENTS, THE
CONTRACTOR SHALL NOTIFY AND RESOLVE THE ISSUE
WITH THE PROJECT TEAM BEFORE COMMENCING ANY
WORK.
10. ALL PERMITS ASSOCIATED WITH THE PROJECT SHALL BE
PAID AND OBTAINED BY THE CONTRACTOR.
11. GENERAL CONTRACTOR SHALL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR JOB CONDITIONS OF THE
JOB SITE, INCLUDING SAFETY OF PERSONS AND PROPERTY
AND COMPLIANCE WITH OSHA SAFETY STANDARDS.
12. WHEN PORTIONS OF THE WORK ARE PERFORMED BY THE
CONTRACTOR ON A DESIGN-BUILD BASIS, THE
CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE
DESIGN OF SUCH SYSTEMS AND FOR THE SECURING OF
ALL ASSOCIATED PERMITS. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE COORDINATION OF ALL DESIGN
BUILD SUB CONTRACTORS.
13. CONTRACTOR SHALL AVOID INTERFERENCE AND CONFLICT
WITH THE BUILDING'S NORMAL OPERATION. CONTRACTOR
TO COMPLY WITH THE BUILDING RULES AND REGULATIONS
REGARDING SCHEDULING AND USE OF ELEVATORS AND
LOADING DOCKS FOR DELIVERY AND HANDLING OF
MATERIALS, EQUIPMENT, AND DEBRIS.
14. ALL KEY NOTES INDICATE NEW ITEMS TYPICALLY U.N.O.
15. CONTRACTOR TO REVIEW ABATEMENT REPORT PRIOR TO
START OF CONSTRUCTION.
PAF POWDER ACTUATED
FASTENER
P/C PRECAST (CONCRETE)
PCF POUNDS PER CUBIC
FOOT
PL PLATE
P.LAM. PLASTIC LAMINATE
PLAS. PLASTER
P.C.P. PORTLAND CEMENT
PLASTER
PJP PARTIAL JOINT
PENETRATION
PR. PAIR
PSF POUNDS PER FOOT
PSI POUNDS PER INCH
P/T POST-TENSIONED
P.T. PRESSURE TREATED
PTN. PARTITION
(R) REMOVE
R., RAD. RADIUS
R.C.P. REFLECTED CEILING
PLAN
R.D. ROOF DRAIN
REF. REFERENCE
REINF. REINFORCING
REQ'D. REQUIRED
RL. RELOCATE
R.O. ROUGH OPENING
RWD. REDWOOD
REV. REVERSED
S.C. SOLID CORE or SLIP
CRITICAL
S.C.D. SEE CIVIL DRAWINGS
SCHED. SCHEDULE
SHR. SHOWER
SIM. SIMILAR
S.J. SCORE JOINT
S.L.D. SEE LANDSCAPING
DRAWINGS
SLRS SEISMIC LOAD RESISTING
SYSTEM
S.M. SHEET METAL
S.M.D SEE MECHANICAL
DRAWINGS
S.O.G. SLAB ON GRADE
SPEC. SPECIFICATION
SQ. SQUARE
S.S.D. SEE STRUCTURAL
DRAWINGS
S.S. STAINLESS STEEL
SSMA STEEL STUD
MANUFACTURERS
ASSOCIATION
STD. STANDARD
STRUCT. STRUCTURAL
S.T.S. SELF TAPPING SCREW
SUSP. SUSPENDED
SYM. SYMMETRICAL
THRU THROUGH
TYP. TYPICAL
TRD. TREAD
T.B. TOWEL BAR
T.C. TOP OF CURB
T & G TONGUE AND GROOVE
THK. THICK
TJ TRUSS JOIST
T.P. TOP OF PAVEMENT
TRANS. TRANSVERSE
T.W. TOP OF WALL
U.N.O. UNLESS NOTED
OTHERWISE
U.T. ULTRASONIC TESTING
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
V.T.R. VENT THROUGH ROOF
w/ WITH w/o WITHOUT
W.C. WATER CLOSET
WF WIDE FLANGE
W.O. WINDOW OPENING
W.P. WORK POINT
EXTERIOR PHOTOPROJECT NOTES PROJECT TEAMABBREVIATIONS PROJECT NARRATIVE SHEET INDEX
AERIAL PHOTO
SYMBOLS LEGEND
VICINITY MAP
N
-DEMO-
D1.00 DEMO FLOOR PLAN
D1.10 DEMO ROOF PLAN
D2.00 DEMO REFLECTED CEILING PLAN
D3.00 DEMO EXTERIOR ELEVATIONS
D4.00 DEMO PHOTOS
PROJECT SCOPE:
THE SCOPE OF THIS PROJECT CONSISTS OF VOLUNTARY STRUCTURAL
IMPROVEMENTS TO THE EXISTING ROOF FRAMING, EXISTING FLOOR FRAMING, AND
ADDITIONAL IMPROVEMENTS FOR ACCESSIBILITY AND ADA PURPOSES.
-CIVIL-
C0.00 CIVIL COVER SHEET
C0.01 EROSION AND SEDIMENT CONTROL NOTES
C1.00 EXISTING CONDITIONS AND DEMOLITION PLAN
C2.00 SITE IMPROVEMENT PLAN
C3.00 PRIVATE CIVIL DETAILS
C4.00 AGENCY STANDARD DETAILS
ALTERNATES
A. (N) ADA ACCESSIBLE KITCHEN AND LIGHTING
B. PAINT EXTERIOR SIDING AND TRIM AT FRONT ELEVATION TO MATCH (E)
C. (N) RAMP
D. REFINISH (E) WOOD FLOORS
E. PAINT ALL INTERIOR WALLS AND STAIN ALL DOORS & INTERIOR TRIM
F. INSTALL (N) CARPET TILES
G. (N) CONCRETE SIDEWALK, STORM IMPROVEMENTS, AND DOWNSPOUT BOOT
REPLACEMENT
H. PAINT ENTIRE EXTERIOR SIDING AND TRIM
I. CONSTRUCT (N) CONCRETE STEM WALLS AROUND OTHER PERIMETER
WALLS PER SHEET S1.10 AND DETAILS 2/S5.10, 3/S5.10 AND 4/A8.00.
J. PROVIDE NEW DESIGN BUILD HVAC SYSTEM PER SHEETS M1.00, M2.00, E1.00
AND E2.00.
-STRUCTURAL-
S0.10 STRUCTURAL GENERAL NOTES
S1.10 FOUNDATION PLAN
S2.10 CEILING FRAMING PLAN
S3.10 ROOF FRAMING PLAN
S4.10 TRUSS ELEVATIONS
S4.11 TRUSS DETAILS
S5.10 FOUNDATION DETAILS
S6.10 FRAMING DETAILS
DESIGN BUILD SCOPE
G.C. AND SUBCONTRACTORS TO REVIEW PLANS, VERIFY EXISTING CONDITIONS AND
PROVIDE CODE REQUIRED MEP DESIGN IN COORDINATION WITH THE
ARCHITECTURAL PLANS. FURTHER MODIFICATIONS MAY BE REQUIRED.
MECHANICAL:
1. DEMO (E) EXHAUST FANS AND REPLACE WITH (N)
2. DEMO (E) FLOOR VENTS AND REPLACE WITH (N)
3. DEMO (E) GAS HVAC SYSTEM AND REPLACE WITH (N) ELECTRIC HVAC
SYSTEM. RE-USE (E) DUCTWORK. REMOVE AND REINSTALL (E) DUCTS AS
NECESSARY FOR STRUCTURAL UPGRADES
PLUMBING:
1. DEMO (E) PLUMBING FIXTURES AND REPLACE WITH (N) - RECONFIGURE
WATER AND WASTE LINES AS NECESSARY TO ACCOMMODATE (N) PLUMBING
FIXTURES
2. PROVIDE NEW FLOOR DRAINS IN RESTROOMS
ELECTRICAL:
1. REMOVE (E) ELECTRICAL PANEL AND REINSTALL AS REQUIRED TO COMPLETE
STRUCTURAL SCOPE. PAINT CONDUIT TO MATCH
2. DEMO (E) LIGHT FIXTURES AND REPLACE WITH (N)
3. PROVIDE POWER FOR (N) SUMP PUMP
ZCS SHALL PERFORM GENERAL REVIEW OF ANY DEFERRED
SUBMITTAL DESIGNS PRIOR TO SUBMITTING TO THE AHJ AND
PRIOR TO CONSTRUCTION IMPLEMENTATION FOR GENERAL
CONFORMANCE TO THE DESIGN INTENT. DEFERRED SUBMITTAL
ITEMS SHALL NOT BE SPECIALLY FABRICATED OR INSTALLED UNTIL
APPROVED BY THE AHJ AND ZCS.
REVISION ID: DATE:
1 ADDENDUM 2 04/25/2024
2 ADDENDUM 3 05/08/2024
-MECHANICAL-
M1.00 DESIGN BUILD DEMO MECHANICAL PLAN
M2.00 DESIGN BUILD MECHANICAL PLAN
DEFERRED SUBMITTALS
-ELECTRICAL-
M1.00 DESIGN BUILD DEMO MECHANICAL PLAN
M2.00 DESIGN BUILD MECHANICAL PLAN
WH
A. ALL EXISTING BUILDING COLUMNS, EXTERIOR WALLS AND
STRUCTURAL MEMBERS TO REMAIN, U.N.O.
B. CONTRACTORS SHALL BE RESPONSIBLE FOR DISPOSAL
OF ALL DEBRIS. PATCH AND REPAIR OF INTERIOR SPACE.
C. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS OF
SAME IN CONTRACT PRICE.
D. FURNISH ALL LABOR AND MATERIALS/EQUIPMENT TO
COMPLETE DEMOLITION AND REMOVAL OF ALL ITEMS AS
INDICATED. CONTRACTOR IS RESPONSIBLE FOR DISPOSAL
OF ALL DEBRIS.CONTRACTOR SHALL KEEP
CONSTRUCTION AREA FREE OF DUST AND DEBRIS FOR
THE DURATION OF CONSTRUCTION. IF ANY QUESTIONS
ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY
THE POINT IN QUESTION WITH DESIGNER BEFORE
PROCEEDING.
E. IN PARTITIONS TO BE REMOVED, REMOVE AND CAP ALL
OUTLETS, SWITCHES, WIRES, THERMOSTATS, ETC., TO
THEIR SOURCE.
F. WHERE INTERIOR PARTITIONS, COLUMN FURRING,
FIXTURES, CABINETRY, DOORS AND DOOR FRAMES, ARE
SCHEDULED FOR REMOVAL, DISPOSE OF ALL DEBRIS AND
PATCH FLOOR AND WALLS AS REQUIRED. PREPARE
SURFACES FOR NEW FINISHES U.N.O. TYPICAL
THROUGHOUT ENTIRE SPACE.
G. REMOVE ALL ABANDONED ELECTRICAL CONDUIT, CABLING
BACKBOARD AND EQUIPMENT, TYPICAL THROUGHOUT
ENTIRE SPACE. AT COMPLETION OF DEMOLITION WORK,
THE CONSTRUCTION AREA(S) SHALL BE LEFT IN “BROOM
CLEAN” CONDITION. ALL DEBRIS AND MISCELLANEOUS
MATERIAL SHALL BE REMOVED.
H. IN ADDITION TO SPECIFIC DEMOLITION SCOPE IDENTIFIED,
PERFORM MISCELLANEOUS DEMOLITION AS REQUIRED TO
SUPPORT NEW CONSTRUCTION. PROVIDE TEMPORARY
SHORING AS REQUIRED.
I. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS
SPEAKER, FIRE ALARM BOX OR SIMILAR DEVICE,
INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED
DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION.
J. RELOCATION OF SMOKE DETECTORS, AND FIRE ALARM
EQUIPMENT, NECESSITATED BY NEW CONSTRUCTION,
SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER
THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE
PERMANENTLY COVERED OR OTHERWISE REMOVED OR
USED FOR OTHER THAN ITS INTENDED PURPOSE.
REMOVE TEMPORARY COVERS DAILY.
K. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND
CONDUIT PERTAINING TO DATA/COMMUNICATIONS AND
TELEPHONE SHALL BE VERIFIED WITH OWNER/TENANT
AND THE PROJECT TEAM.
DEMO PLAN GENERAL NOTES
(E) WALL TO REMAIN
(E) WALL TO BE DEMOLISHED
(E) ELEMENT TO BE DEMOLISHED
(E) DOOR TO BE DEMOLISHED
DEMO PLAN LEGEND
1 2 3 4 5
A
B
C
D
E
1 4
C
D3.00 1
D3.00
UP
UP
UP
DN
UP DN
D3.003
A
D3.00
9 99 9
BB
B
B
B
D D
D
F
F
F
A
D4.10 12
OFFICE
MAIN HALL
OFFICE
OFFICE
HALLWAY
WOMEN'S RR
JAN.
105A
MEN'S RR
KITCHEN
STAGE
STORAGE
STORAGE
SIDE STAGE
STORAGE ENTRY
G
13 13
EACH OF THE FOLLOWING ITEMS SHALL BE BID AS
ADDITIVE ALTERNATES:
A. DEMO ALL CASEWORK, REMOVE AND SALVAGE
SINKS, REFRIGERATOR, RANGE AND ALL OTHER
APPLIANCES TO RETURN TO OWNER. DEMO
PORTIONS OF WALL AND CASEWORK IN BUTLER'S
PANTRY. DEMO FLOOR FINISH AND PREP FOR (N)
B. PREP EXTERIOR SIDING AND TRIM FOR (N) PAINT
C. DEMO DOOR AND PORTION OF WALL FOR (N)
RAMP
D. PREP WOOD FLOOR FOR (N) FINISH
E. PREP ALL INTERIOR WALLS FOR PAINT AND PREP
ALL DOORS & INTERIOR TRIM FOR (N) STAIN
F. REMOVE CARPET AND PREP FOR (N) FLOORING
G. DEMO (E) PATHWAY FOR (N) PAVED SIDEWALK
# DEMO ALTERNATE KEYNOTES
1. DEMO (E) WINDOW
2. DEMO ALL (E) PLUMBING FIXTURES, TOILET
PARTITIONS, AND RESTROOM ACCESSORIES
3. DEMO (E) STAIRS, RAILING AND DECK
4. DEMO (E) STAIR
5. DEMO (E) RAMP AND RAILING
6. DEMO (E) CONCRETE PAD
7. DEMO (E) RAILING
8. DEMO PORTION OF (E) WALL FOR (N) OPENING
9. DEMO (E) COLUMN
10. DEMO (E) FLOOR VENT - PATCH FLOOR FRAMING/
SHEATHING AS NECESSARY AND PREP FOR (N)
FLOORING
11. REMOVE (E) DOOR AND PREP FOR REINSTALLATION.
REMOVE HINGES AND STRIKE ON (E) DOOR FRAME
AND PREP FOR REINSTALLATION
12. DEMO (E) WALL FINISH AND PROTECT IN PLACE (E)
WINDOWS
13. DEMO (E) WALL FINISH FOR (N) COLUMNS PER
STRUCT. REMOVE (E) TRIM AND PREP FOR
REINSTALLATION
14. DEMO (E) FLOOR FINISH AND PREP FOR (N)
# BASE BID DEMO PLAN KEYNOTES
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESSIONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7, 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/7
/2
:4
:2
P M
A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
D1.00
DEMO FLOOR
PLAN
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
D1.00 3/16" = 1'-0"
DEMO FLOOR PLAN1
N
REVISION ID: DATE:
1 ADDENDUM 2 04/25/2024
2 ADDENDUM 3 05/08/2024
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESSIONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7, 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/8
/2
:4
:3
A M
A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
A0.10
FINISH
SCHEDULES
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
CPT CARPET TILE ROOMS 102, 103, & 106 BENTLEY MILLS SERVE IT UP, SLICE AND DICE - ALTERNATE F: (N) CARPET TILES
WD WOOD ROOMS 101 & 111 - - - ALTERNATE D: REFINISH WOOD FLOORS
ROOMS 105, 105A, 107, & 108
MANNINGTON
COMMERCIAL
LINO, STONE - -
SV SHEET VINYL ROOM 109
MANNINGTON
COMMERCIAL
LINO, STONE - ALTERNATE A: PROVIDE NEW FLOORING IN KITCHEN
FINISH
CODE
MATERIAL LOCATION MANUFACTURER STYLE / COLOR PRODUCT NOTES INSTALLATION NOTES
FLOOR FINISHES
WB WOOD BASE INTERIOR - COLOR TO MATCH EXISTING BASE 1X8 TRIM -
RB RUBBER BASE RESTROOMS ROPPE BLACK BROWN 4"
PROVIDE PREFORMED INSIDE & JOB FORMED
OUTSIDE CORNERS
FINISH
CODE
MATERIAL LOCATION MANUFACTURER STYLE / COLOR SIZE / THICKNESS INSTALLATION NOTES
WALL BASE FINISHES
CLD ACOUSTIC PANEL MAIN HALL ARMSTRONG DIRECT-ATTACH CEILING PANELS 24"x48"/24"x72" SURFACE-MOUNTED
GYP GYPSUM INTERIOR CERTAINTEED - 5/8" -
FINISH
CODE
MATERIAL LOCATION MANUFACTURER STYLE / COLOR SIZE/NRC RATING INSTALLATION NOTES
CEILING FINISHES
FT2 FRP TRIM RESTROOMS SCHLUTER VINPRO-RO, 3MM ALUMINUM BRUSHED CHROME ANODIZED INSTALL AT OUTSIDE CORNERS
FT1 FRP TRIM RESTROOMS SCHLUTER VINPRO-S, 3MM ALUMINUM BRUSHED CHROME ANODIZED
INSTALL AT TOP EDGES AND INNER CORNERS -
MITER EDGES AT INNER CORNERS
FRP
FIBERGLASS REINFORCED
PANELS
RESTROOMS MARLITE SYMMETRIX, SUBWAY, WHITE - PROVIDE ON ALL WALLS UP TO 4'-0" A.F.F.
EP EPOXY PAINT RESTROOMS SHERWIN WILLIAMS AGREEABLE GRAY SEE FINISH NOTES -
PT3 PAINT DOORS, FRAMES, TRIM SHERWIN WILLIAMS PURE WHITE SEE FINISH NOTES ALTERNATE E: PAINT ALL INTERIOR DOORS AND TRIM
PT2 PAINT EXTERIOR WALLS, U.N.O. SHERWIN WILLIAMS MATCH EXISTING SEE FINISH NOTES
ALTERNATE B: PAINT EXTERIOR WALLS ON WEST
ELEVATION
PT1 PAINT INTERIOR WALLS, U.N.O. SHERWIN WILLIAMS AGREEABLE GRAY SEE FINISH NOTES ALTERNATE E: PAINT ALL INTERIOR WALLS
FINISH
CODE
MATERIAL LOCATION MANUFACTURER STYLE / COLOR FINISH SHEEN INSTALLATION NOTES
PAINT/WALL FINISHES
GENERAL NOTES:
A. PROVIDE TRAP PRIMER CONNECTION AS REQUIRED BY CODE.
B. IF ‘ADA’ IS INDICATED ON THE DRAWINGS, INSTALL ALL COMPONENTS TO MEET ADA REQUIREMENTS.
C. ALL PIPING SHALL BE CONCEALED IN WALLS OR ABOVE CEILING, U.N.O. ON PLANS.
D. SUPPORT PIPES TIGHT TO STRUCTURE WHEREEVER POSSIBLE.
E. ALL HORIZONTAL WASTE LINES TO HAVE MINIMUM OF ¼” PER FOOT SLOPE U.N.O.
F. PROVIDE FULL-WAY COLD WATER AND HOT WATER SUPPLY SHUT-OFF VALVES AT EACH UNIT FIXTURE.
G. PROVIDE ACCESS PANEL TO SHUTOFF VALVES WHERE REQUIRED.
H. PROVIDE MECHANICAL WATER HAMMER ARRESTOR AT QUICK-ACTING VALVES, SIZED AND INSTALLED IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS.
I. PROVIDE CLEANOUTS AT THE BASE OF ALL WASTE STACKS, AT UPPER TERMINALS OF HORIZONTAL DRAINAGE PIPES, IN LOCATIONS REQUIRED BY CODE AND/OR AS SHOWN IN DRAWINGS.
J. HEAT TRACE AND INSULATE ALL WASTE AND WATER PIPING EXPOSED TO FREEZING.
K. ALL FLOOR DRAINS AND FLOOR SINKS AND SIMILAR TRAPS SHALL BE PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEAL. UNLESS TRAP PRIMER
P04 MOP SINK FLORESTONE MSR-2424/MSR-3624 - - - - - - 24" x 24"
P03
WALL MOUNTED
URINAL
AMERICAN STANDARD 6002001.020 - - -
MANUAL FLUSH
VALVE
AMERICAN STANDARD 6045.051.002 -
P02
FLOOR MOUNTED
TOILET
SLOAN ST-2029 - - - TOILET SEAT BEMIS
1955CT/1955SSCT &
2155CT/2155SSCT
INSTALL PER ADA STANDARDS
P01 DROP IN SINK KOHLER K-2699-1-0 - - - FAUCET KOHLER K-28126-4N-BL INSTALL PER ADA STANDARDS
TYPE DESCRIPTION MANUFACTURER MODEL NUMBER W CW HW DESCRIPTION MANUFACTURER MODEL NUMBER NOTES
FIXTURE CONNECTIONS TRIM / ACCESSORIES
PLUMBING SCHEDULE - B.O.D. (DESIGN / BUILD SCOPE) DESIGN / BUILD SCOPE. PLUMBER TO VERIFY BALANCE
OF FIXTURES & ACCESSORIES. INSTALL PER CODE.
LUMINAIRE SCHEDUL NOTES
1. INCLUDES BATTERY BACKUP.
2. EXHUAST FAN SHALL BE ENERGY STAR CERTIFIED AND OPERATIONAL AT
50CFM CONTINUOUS WHILE OCCUPIED OR 70CFM INTERMITTENTLY.
3. PROVIDE OCCUPANCY SENSORS
GENERAL NOTES:
A. DIMMING CONTROL PROTOCOL (0-10VDC, LINE VOLTAGE, DALI, ETC.) COMPARABLE WITH LIGHTING CONTROL SYSTEM AS SPECIFIED AND SHOWN IN DRAWINGS.
B. PROVIDE ± 12” ADJUSTABILITY IN AIRCRAFT CABLE LENGTH WHERE USED.
C. COORIDNATE ALL CEILING TYPES WITH LUMINAIRE LOCATIONS PRIOR TO ORDERING LUMINAIRES. COORIDNATE INSTALLATION WITH REFLECTED CEILING PLANS.
D. SPECIFIED MANUFACTURERS ARE APPROVED TO SUBMIT BID. INCLUSION DOES NOT RELIEVE MANUFACTURER FROM SUPPLYING PRODUCT AS DESCRIBED.
E. PROVIDE SUBMITTALS THAT INCLUDE THE LUMINAIRE, LAMP AND BALLAST INFORMATION OF EACH LUMINAIRE, WITH APPLICABLE OPTIONS CLEARLY CHECKED OR HIGHLIGHTED. PROVIDE SHOP DRAWINGS FOR ARCH. REVIEW.
F. REMOTE BALLAST/DRIVERS: UL LISTED FOR THEIR APPLICATION. BALLASTS/DRIVERS MARKED AS UL RECOGNIZED COMPONENT BUT NOT UL LISTED ARE SUBJECT TO REMOVAL AND REPLACEMENT AT NO COST TO OWNER.
G. PROVIDE COMMISSIONING OF THE LIGHTING AND LIGHTING CONTROLS IN ACCORDANCE WITH OREGON STATE LIGHTING COMMISSIONING REQUIREMENTS.
H. PROVIDE OCCUPANCY SENSORS TO ALL ROOMS AS REQUIRED BY ASHRAE STANDARD 90.1-2019
EF EXHAUST FAN BROAN QTXE 110 18W C BY CONTRACTOR - - - 2, 3
V1 VANITY LIGHT WAC LIGHTING WS-35020-AB 27W 120 BY CONTRACTOR 1439 3000 K OCCUPANCY SENSOR 3
X1 LED EXIT SIGN
LITHONIA
LIGHTING
EXRD EL M6 1W 120 - - - - 1
F4 PENDANT G LIGHTING
GL-2555-BB0-E-PAB-24”
STEM
48W 120 BY CONTRACTOR 4567 3500 K DIMMING TO 10% -
F3 LED ROUND G LIGHTING GL-3560-BB0-E-PAB 48W 120 BY CONTRACTOR 4567 3500 K DIMMING TO 10% 3
F2 PENDANT G LIGHTING
GL-2555-BB0-E-PAB-36”
STEM
48W 120 BY CONTRACTOR 4567 3500 K DIMMING TO 10% -
F1 6" RECESSED CAN
LITHONIA
LIGHTING
LDN6 40/20 LO6WR - 120 BY CONTRACTOR 2000 3500 K OCCUPANCY SENSOR 3
TYPE DESCRIPTION MANUFACTURER MODEL NUMBER / NAME
INPUT
WATTS
VOLTAGE
DRIVER / POWER
SUPPLY
LUMENS
COLOR
TEMPERATURE
LIGHTING CONTROLS NOTES
LUMINAIRE SCHEDULE - B.O.D. (DESIGN / BUILD SCOPE) DESIGN / BUILD SCOPE. ELECTRICTIAN TO VERIFY
BALANCE OF FIXTURES & ACCESSORIES.
NOTE: ALL MATERIALS ARE BASIS OF DESIGN. SEE SPECIFICATION FOR FURTHER INFORMATION. SUBSTITUTIONS REQUIRE SHOP DRAWINGS / CUT SHEETS AND PHYSICAL SAMPLES FOR SELECTION AND APPROVAL BY
ARCHITECT / OWNER. ALLOW 15 BUSINESS DAY'S FOR APPROVAL REVIEW.
PNL TOILET PARTITIONS SEE PLANS SCRANTON TRADITIONAL 2600 72: PANEL HEIGHT
BRONZE, ROTARY
BRUSHED
SND SANITARY NAPKIN DISPOSAL SEE PLANS BOBRICK B-254 10 11/16" W, 15 1/8" H, 4 1/16" D
304-STAINLESS W/
SATIN-FINISH
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
TP
SURFACE MOUNTED TOILET PAPER
DISPENSER
SEE PLANS BOBRICK B-4288 6 1/16" W, 11" H, 5 15/16" D
304-STAINLESS W/
SATIN-FINISH
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
SD SURFACE-MOUNTED SOAP DISPENSER SEE PLANS BOBRICK B-2111 4 3/4" W, 8 1/8" H, 3 1/2" D
304-STAINLESS W/
SATIN-FINISH
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
PD2
SURFACE-MOUNTED CONVERTIBLE PAPER
TOWEL DISPENSER/WASTER RECEPTACLE
SEE PLANS BOBRICK B-3949 17 1/2" W, 56 5/16" H, 4 1/8" D
304-STAINLESS W/
SATIN-FINISH
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
MR WALL MOUNTED MIRROR - TEMPERED SEE PLANS KOHLER K-26052 22" W, 34" H CPL POLISHED CHROME
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
GB ADA COMPLIANT GRAB BARS SEE PLANS BOBRICK B-6806 x 18, x 36, x 42 18" L, 36" L, 42" L
304-STAINLESS W/
SATIN-FINISH
SEE ADA TYPICAL MOUNTING
REQUIREMENT DIAGRAM
ACCESSORY
CODE
ACCESSORY LOCATION MANUFACTURER MANUFACTURER CODE SIZE FINISH INSTALLATION NOTES
RESTROOM ACCESSORIES
PL2 PLASTIC LAMINATE CABINETRY/SHELVING WILSONART BLONDE ECHO - -
PL1 PLASTIC LAMINATE COUNTERTOPS/BACKSPLASH WILSONART BLACK ALICANTE - -
FINISH
CODE
MATERIAL LOCATION MANUFACTURER STYLE / COLOR SIZE NOTES
CASEWORK FINISHES
TR4 ALUMINUM NGP NGP 713 HALF SADDLE THRESHOLD CONCRETE TO WOOD FLOOR
TR3 ALUMINUM NGP NGP 659 OFFSET SADDLE THRESHOLD COMPOSITE DECKING TO SHEET VINYL
TR2 ALUMINUM SCHLUTER VINPRO-T (E) CARPET TILE TO SHEET VINYL
TR1 ALUMINUM SCHLUTER VINPRO-U (E) CARPET TILE TO WOOD FLOOR ALTERNATE: 'C' AND 'F'
FINISH
CODE
MATERIAL MANUFACTURER STYLE / COLOR PRODUCT NOTES INSTALLATION NOTES
FLOORING TRANSITIONS
REVISION ID: DATE:
2 ADDENDUM 3 05/08/2024
A. REFER TO ARCHITECTURAL FLOOR PLAN FOR
ADDITIONAL DIMENSIONS.
B. ALL DIMENSIONS ARE REFERENCED TO FACE OF
FINISH U.N.O.
C. ALL HEIGHT REFERENCES ARE TAKEN FROM
DATUM-T.O.S. FOR AREA INDICATED.
D. PROVIDE WALL BACKING FOR REINFORCEMENT AS
REQUIRED.
E. PROVIDE SOLID BLOCKING FOR ALL 'J' BOXES
SUSPENDED LIGHT AND CEILING FAN FIXTURES,
TELEVISION SUPPORT, ARTIFACT SHELVES AND
ANY OTHER CEILING MOUNTED EQUIPMENT.
F. ALL LIGHT FIXTURE TRIM RINGS, EXPOSED
CONDUITS, 'J' BOXES, HVAC GRILLS, EMERGENCY
LIGHT FIXTURES, DUPLEX OUTLETS AND FACE
PLATES SHALL BE PAINTED TO MATCH THE
ADJACENT FINISH U.N.O.
G. ANY LIGHT NOT DIMENSIONALLY LOCATED TO BE
CENTERED IN THE CEILING TILE, CEILING AREA, OR
ROOM AS APPLICABLE. ALL "CAN" TYPE FIXTURES
TO BE MOUNTED IN THE CENTER OF THE CEILING
TILES U.N.O.
RCP GENERAL NOTES:
CEILING LEGEND :
(N) GYPSUM BOARD CEILING AND INSULATION
(E) GYPSUM BOARD CEILING
CEILING FINISHES
GYP GYPSUM BOARD - PAINT PT1
LIGHTING HVAC
REGISTERS
CEILING HEIGHT
VAR VARIES
M.E. MATCH EXISTING
ADDITIONAL NOTES
1. NOT USED
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTESNOTES
ACT
8'-0"
REFLECTED CEILING LEGEND:
1. (N) TIMBER TRUSS PER STRUCT. - STAIN
2. (E) SKYLIGHT TO REMAIN
3. (N) SURFACE MOUNTED ACOUSTIC PANEL
4. (N) COLUMN PER STRUCT.
5. PATCH PORTION OF CEILING
6. (N) ATTIC HATCH 20"x30"
7. (N) TRIM FOR (E) ATTIC HATCH
8. (N) HEADER PER STRUCT. - PROVIDE (N) WOOD
TRIM
9. PAINT (N) ROOF RAFTERS - MATCH (E)
# REFLECTED CEILING KEYNOTES
1 2 3 4 5
A
B
C
D
E
GYP
10' - 4"
GYP
10' - 4"
GYP
10' - 4"
MEN'S RR
WOMEN'S RR
HALLWAY
F1
F1
F1
F1
F1
X1
EF
EF
V1
A
GYP
VAR
GYP
14' - 9"
GYP
VAR
GYP
VAR
MAIN HALL
F1 F1
F3
F3
44 4 4
GYP
9' - 0"
GYP
VAR
STORAGE
F1
F1
STAGE
EQ. 9' - 0" EQ.
F1
A7.10
2 2
TYP.
V1
E Q
E Q
E Q
E Q
E Q
E Q
E Q
E Q
EQ EQ EQ EQ
C1
C1
C1
C1 C1
C1
C1
F2
F2
F4 F4
E Q
E
Q
F2
F2
EQ EQ
E Q
E Q
E Q
E Q
EQ EQ
EQ. EQ.
C2
GYP
10'-4"
F4
F1 RECESSED CAN
F2 PENDANT
F3 SURFACE MOUNT ROUND CEILING LIGHT
F4 PENDANT
X1 EXIT SIGN
EF EXHAUST FAN
V1 VANITY LIGHT
FIXTURE SCHEDULE
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESSIONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7, 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/7
/2
:4
:4
P M
A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
A2.00
REFLECTED
CEILING PLAN
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
A2.00 3/16" = 1'-0"
REFLECTED CEILING PLAN1
N
REVISION ID: DATE:
1 ADDENDUM 2 04/25/2024
2 ADDENDUM 3 05/08/2024
C
A7.00 3
A7.00
5' - 8"
114 SF
MEN'S RR
98 SF
WOMEN'S RR
105A
P02
P03 P03
P02
P02
P01
P01
P04
C L R
C L R
1'-5" 2'-10" 1'-5"1' - 6"
1' - 6"
9' - 1" 2' - 0 1/2"
8' - 5"
7 1/2"
2' - 0 1/2"
A5.10
RB
EP
PD2
PL1 PL2 FRP
FT1
FT2
EP
RBFRP
FT1
FT1
FT2
RB GB
EP
TPFRP PNL
FT1
RB
EP
FRP
SD PL2PL1
MR
V1
A9.00
SIM.
FT1
RB
EP
GB SND TP
FRP
FT1
TP SND RB
EP
FRP
FT2
FT1
V1
EP
RBPD2 PL1 PL2
FRP
FT1
RB
EP
FRP
PL2 PL1
SD
MR
V1
A9.00
SIM.
FT1
FLOORING
BASE
EX# EXISTING TO REMAIN
RB# RUBBER BASE
WB# WOOD BASE
WALLS
EX# EXISTING TO REMAIN
ME# MATCH EXISTING
PT# PAINT
EP# EPOXY PAINT
FT# FRP TRIM
FRP FIBERGLASS PANELS
RESTROOM ACCESSORIES
TP# TOILET PAPER DISPENSER
MR# MIRROR
GB GRAB BAR
SD# SOAP DISPENSER
PD# PAPER TOWEL DISPENSER
SND SANITARY NAPKIN DISPOSAL
FLOORING TRANSITIONS
TR# TRANS PROFILE #
CASEWORK
EX# EXISTING TO REMAIN
ME# MATCH EXISTING
PL# PLASTIC LAMINATE
WALL PROTECTION
EX# EXISTING TO REMAIN
ME# MATCH EXISTING
CG# CORNER GUARD
EX# EXISTING TO REMAIN
ME# MATCH EXISTING
SV SHEET VINYL
WD WOOD FLOORING
CPT CARPET TILE
ROOM FINISH ABBREVIATIONS:
MISC.
WC# WINDOW COVERINGS
CLD ACOUSTIC PANEL
1. PROVIDE OPAQUE FILM
2. (N) FLOOR VENT
3. (N) STAINLESS STEEL FLOOR DRAIN WITH
SURFACE MEMBRANE CLAMP
# FINISH KEYNOTES
1. (N) FLOOR FINISH SHALL EXTEND UNDER CASEWORK
2. PAINT ALL WALLS BEHIND CASEWORK
A. ALL PRODUCTS ARE TO BE INSTALLED PER
MANUFACTURERS INSTRUCTIONS, USING
MANUFACTURERS ADHESIVES, TOOLS AND METHODS.
B. REFER TO SPECIFICATIONS AND FINISH SCHEDULES
FOR FURTHER FINISH MATERIAL PRODUCT
INFORMATION.
C. SEE ELEVATIONS FOR ADDITIONAL FINISHES
D. FOR CEILING HEIGHTS AND ADDITIONAL FINISHES SEE
RCP'S
E. COORDINATE ALL OWNER FURNISHED EQUIPMENT,
ACCESSORIES, AND FURNITURE WITH OWNER.
F. FIELD VERIFY ALL DIMENSIONS PRIOR TO
FABRICATION.
G. ALL FLOOR TRANSITIONS ARE TO OCCUR DIRECTLY
BENEATH DOOR U.N.O.
H. ALL FLOOR TRANSITIONS ARE TO BE ADA COMPLIANT.
I. PROVIDE STAINLESS STEEL TRANSITION
STRIPS/REDUCERS AT ALL LOCATIONS WHERE
CERAMIC TILE MEETS A DIFFERENT MATERIAL.
PROVIDE APPROPRIATE TRANSITIONS
STRIPS/REDUCERS AT ALL OTHER LOCATIONS
BETWEEN DIFFERING MATERIALS U.N.O. SEE
TRANSITION CALL OUTS. ALL TRANSITIONS TO MEET
ADA REQUIREMENTS.
J. REFER TO FINISH PLAN FOR LOCATION OF CORNER
GUARDS. ALL CORNER GUARDS ARE TO BE
INSTALLED WITH BOTTOM OF CORNER GUARD AT TOP
OF WALL BASE AND EXTEND 48" AFF.
K. ALL GYPSUM CEILING AND SOFFITS TO BE PAINTED
PT1 U.N.O.
L. ALL METAL ACCESS PANELS, COVER PLATES, VENTS
AND GRILLES TO BE PAINTED TO MATCH THE
SURFACE IT IS LOCATED ON, UNLESS PREFINISHED.
M. ALL BASE CABINETS AND UPPER CABINETS ARE TO
RECEIVE PLASTIC ON ALL EXPOSED EXTERIOR
SURFACES AS INDICATED ON INTERIOR ELEVATIONS.
ALL INTERIOR SURFACES TO RECEIVE WHITE
MELAMINE ON ALL CONCEALED SURFACES. RUN
WOOD GRAIN IN VERTICAL DIRECTIONS AND USE
0.020" THICK MATCHING VINYL EDGEBAND ON
CABINET DOORS AND DRAWERS.
N. ALL COUNTERTOPS ARE RECEIVE BACKSLASHES TO
MATCH. PROVIDE PAINTABLE SEALANT AT WALL.
O. PAINT VISIBLE PORTION OF INSIDE OF DUCT WORK
FLAT BLACK.
P. PAINT SHEEN - WALL: SATIN/EGG SHELL, CEILING:
FLAT/MATTE, TRIM & DOOR FRAMES: SEMI-GLOSS
Q. INSTALL (N) 1/4" APA PLYWOOD UNDERLAYMENT
OVER ALL EXISTING WOOD SUBFLOORS TO RECIEVE
(N) FINISHES. INSTALL WITH SCREWS 2" O.C. AT
PERIMITER AND 4" ACCROSS FIELD. OFFSET PANELS
12" MIN.
GENERAL FINISH NOTES:
ADDITIONAL NOTES:
EXPIRES: 06-30-24
R
D
EG
IS
TE
RE
P
L
ROFESSIONA
81129PE
OREGON
E
RNG
I NE E
Z
S
A . S
J
7, 2
Y
A C
H
AR
S
TO
K Ee un 2
45 Hawthorne Street, Medford, Oregon 97504 | 541-500-8588
PROJECT NO.
DATE:
DRAWN:
CHECKED:
O N
E I N
C H
E Q
U A
L S
F U
L L
S C
A L E
/7
/2
:4
:4
P M
A u to d e s k D o c s /M
.A s h la n d
C o m m u n it y C e n te r
P io n e e r
H a ll/
M
A
R C
H
R
.r v t
A7.00
ENLARGED PLANS
& INTERIOR
ELEVATIONS
M-0298-22
ASHLAND
COMMUNITY
CENTER
RENOVATION
CITY OF ASHLAND
74 WINBURN WAY
ASHLAND, OR 97520
03-13-2024
WYH
JRR
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T S
B
ID
P E
R M
IT
A7.00 1/4" = 1'-0"
ENLARGED RESTROOM PLAN - BASE BID1
A7.00 1/4" = 1'-0"
MEN'S RR - WEST2
A7.00 1/4" = 1'-0"
MEN'S RR - NORTH3
A7.00 1/4" = 1'-0"
MEN'S RR - EAST4
A7.00 1/4" = 1'-0"
MEN'S RR - SOUTH5
A7.00 1/4" = 1'-0"
WOMEN'S RR - WEST6
A7.00 1/4" = 1'-0"
WOMEN'S RR - NORTH7
A7.00 1/4" = 1'-0"
WOMEN'S RR - EAST8
A7.00 1/4" = 1'-0"
WOMEN'S RR - SOUTH9
REVISION ID: DATE:
2 ADDENDUM 3 05/08/2024
| Sheets |
| A0.10 - FINISH SCHEDULES |
| A2.00 - REFLECTED CEILING PLAN |
| A7.00 - ENLARGED PLANS & INTERIOR ELEVATIONS |
| D1.00 - DEMO FLOOR PLAN |
| G0.00 - COVER SHEET |
File details come from the government source that posted it. Updated .