Drawing - PLUM.pdf
PDF 5 MB Posted
- Attached to
- Solicitation Notice - LBJ Consolidation & Switchgear Federal contract opportunity
- Solicitation number
- 47PM0121R0013
About this file
This solicitation notice seeks proposals for a firm fixed-price construction contract to renovate floors 3, 4, 6, and 7 of the Lyndon B. Johnson Federal Building in Washington, D.C. The work includes interior alterations, open workspace construction, HVAC and electrical upgrades including significant renovations to the building's switchgear systems. Proposals are due June 4, 2021. The contract is set aside for small businesses with average annual receipts less than $39.5 million over the past three years. A virtual pre-proposal conference will be held on May 5, 2021. The General Services Administration and Department of Education will award the contract to reconstruct approximately 198,369 square feet of existing space as open office and meeting areas to accommodate adding around 600 employees from leased spaces.
View the file
Other files for this federal contract opportunity
Show all 50
Solicitation Notice - LBJ Consolidation & Switchgear has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BPA
FIXTURE UNIT RATING PIPE SIZE J.R. SMITH PPP, INC JOSAM REMARKS
1-11
12-32
33-60
61-113
114-154
155-330
3/4"
1"
1"
1"
1"
1"
SC-125
SC-375
SC-500
SC-750
SC-1000
SC-1250
75001
75002
75003
75004
75005
75006
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
STAINLESS STEEL
NOTE: REFER TO MANUFACTURER'S INSTALLATION GUIDELINES
TYPE APPROVED MANUFACTURERS/MODEL NO. REMARKS
POINT OF USE
WATTS LFUSG-B, CHICAGO 131-FMAB, LAWLER
570, BRADLEY S59-4000A, POWERS LFE480
LEAD FREE, ASSE 1070 CERTIFIED, WITH
INTEGRAL CHECKS AND LOCK FEATURE
FIXTURE TYPE AREAS DESCRIPTION MANUFACTURER MODEL FINISH/COLOR
DRINKING FOUNTAIN
TYPE COMMENTS
FAUCET
LAVATORY
SINK
SINK
URINAL
URINAL
WATER CLOSET
WATER CLOSET
Corridor
Public Restrooms
Private Restroom and Mother's
Room
Pantry
Public Restrooms
Private Restrooms
Mother's Room
Pantry
Public Restrooms
Public Restrooms
Public Restrooms and Private
Restrooms
Public Restrooms and Private
Restrooms
Water Cooler - dual height w/ bottle filter (Refrigerated)
Undermount lavatory at Public
Restrooms
Undermount Sink at Mother's Room
Drop-In pantry sink at Pantry
Urinal and Flushometer
Urinal and Flushometer - Barrier
Free Height
Water Closet anf Flushometer Combo -
Barrier Free Height
Water Closet and Flushometer
Combo
Undermount lavatory at Private
Restrooms
Elkay
Bradley Corporation
Kallista
Kohler
Kohler
Kohler
Elkay
Just Manuf. Co
Sloan
Sloan
Sloan
Sloan
LZWS-LRPBM28K
Metro Vegas Verge S53-3300
(0.35GPM), 6-3300
P-24409 (1.2gpm) and P23180
Purist - Pull Out (1.5 GPM)
Vetricyl Rectangle K-2882
Bachata K-2609-SU
Lustertone ELUHAD211555
SL_ADA_2133_A_GR_3_6
WEUS-1000.1201 (0.125 gpf)
WETS-2451.1201 Alternate ADA installation (1.1 gpf)
WETS-2451.1201 (1.1 gpf)
Stainless Steel
White
White
Satin Stainless
Steel
Stainless Steel
Satin
Stainless Steel
White
Satin
Stainless Steel
Stainless Steel
Satin
Stainless Steel
White
White
Coordinate and verify in field the chase clearance to meet manfu. requirements
Provide insulation p trap cover, b. o. d. Lav-Guard 2
Standard Height
Barrier Free Height
Barrier Free Height. Provide commercial elongated toilet seat: Kholer K-467 0-SC
Standard Height. Provide Commercial Elongated Toilet
Seat: K-4670-SC
FAUCET
FAUCET
LAVATORY
Provide insulation p trap cover, Handi Lav-Guard 27692
WEUS-1000.1201 (0.125 gpf)
Provide insulation p trap cover, b. o. d. Lav-Guard 2
Provide insulation p trap cover, b. o. d. Lav-Guard 2
P RISER DESIGNATION
(SOIL, VENT, WASTE, COLD WATER)
EXISTING PIPING TO BE REMOVED
PRESSURE REDUCING VALVE
EXISTING PIPING TO REMAIN
DOMESTIC HOT WATER RETURN PIPING
SANITARY DRAIN PIPING
SANITARY VENT PIPING
IW INDIRECT WASTE PIPING
DOMESTIC COLD WATER PIPING
DOMESTIC HOT WATER PIPING
SLOPED CHANGE IN PIPE ELEVATION
ARROW INDICATES DIRECTION OF FLOW
PITCH PIPE DOWN IN DIRECTION OF ARROW
SHOCK ABSORBER
HOSE BIBB WITH VACUUM BREAKER
WALL HYDRANT
CLEANOUT / PLUGGED OUTLET
CLEAN-OUT DECK PLATE
"P" TRAP
VACUUM BREAKER
BOTTOM PIPE CONNECTION
TOP PIPE CONNECTION
ELBOW TURNED DOWN
ELBOW TURNED UP / CONN. TO VERTICAL LINE
SHUTOFF VALVE IN VERTICAL
SHUTOFF VALVE
CHECK VALVE
BACKFLOW PREVENTER ASSEMBLY
ANGLE RELIEF VALVE
UNION
SLEEVE
FLOOR DRAIN
LEGEND
BALL VALVE
OS&Y (OUTSIDE SCREW & YOKE) VALVE
PLUMBING
DWG. DRAWING
L
SK SINK
HOT WATER RETURNHWR
AUTOMATIC BALL DRIPA.B.D.
PITCH PER FOOTPPF
INVERT ELEVATIONINV. EL.
CENTER LINEC
ABBREVIATIONS
WALL HYDRANTWH
WATER CLOSETWC
WASTEW
VACUUM BREAKERVB
VENTV
URINALUR
UP (PENETRATES FLOOR SLAB)UP
UNLESS OTHERWISE NOTEDUON
TYPICALTYP.
SANITARYSAN
SHOCK ABSORBERSA
SOILS
POUNDS PER SQUARE INCHPSI
OUTSIDE SCREW & YOKE GATE VALVEOS&Y
OUTSIDE DIAMETEROD
NOT TO SCALENTS
NORMALLY OPENNO
NOT IN THIS CONTRACTN.I.C.
NORMALLY CLOSEDNC
MINIMUMMIN.
MAXIMUMMAX.
MOP RECEPTORMR
LAVATORYLAV
INCHIN
INDIRECT WASTEIW
INSIDE DIAMETERID
HOT WATERHW
HUNG CEILINGHC
HOSE BIBBHB
GALLONSGAL.
GALLONS PER MINUTEGPM
GENERAL CONTRACTORGC
FEETFT.
FLOORFLR.
FIXTURE UNITFU
FLOOR DRAINFD
ELECTRIC WATER COOLEREWC
ELEVATIONEL.
DISH WASHERDW
DRAINDR
DOWN (PENETRATES FLOOR SLAB)DN.
DIAMETERDIA
CONTINUATIONCONT.
CONNECTCONN
CEILINGCLG.
COLD WATERCW
CHECK VALVECV
CLEANOUT DECK PLATECOPD
CLEANOUTCO
BOTTOM OF PIPEBOP
BUILDINGBLDG.
ABOVE FINISHED FLOORA.F.F.
DOMESTIC WATER HEATERDWH
THERMOSTATIC MIXING VALVETMV
PLUMBING WATER HAMMER ARRESTOR SCHEDULE
THERMOSTATIC MIXING VALVE SCHEDULE
PLUMBING FIXTURES SCHEDULE
P-00-01
DRAWING NO.
PLUMBING DRAWING INDEX
# DESCRIPTION SCALE
PD-13-01
PLUMBING NOTES, SYMBOLS, AND ABBREVIATIONS NTS
NTS
1/8" = 1' 0"
PD-14-01
PD-16-01
PD-17-01
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 3 -EAST & WEST
P-13-00
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
1/8" = 1' 0"
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 4 -EAST & WEST
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 6 -EAST & WEST
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 7 -EAST & WEST
P-13-01
P-14-01
P-16-01
P-17-01
P-14-00
P-16-00
P-17-00
PLUMBING FLOOR PLAN - LEVEL 3 -EAST & WEST
PLUMBING FLOOR PLAN - LEVEL 4 -EAST & WEST
PLUMBING FLOOR PLAN - LEVEL 6 -EAST & WEST
PLUMBING FLOOR PLAN - LEVEL 7 -EAST & WEST
PLUMBING FLOOR PLAN - LEVEL 3 -OVERALL
PLUMBING FLOOR PLAN - LEVEL 4- OVERALL
PLUMBING FLOOR PLAN - LEVEL 6 - OVERALL
PLUMBING FLOOR PLAN - LEVEL 7 - OVERALL
P-14-03
P-16-03
P-17-03
PLUMBING FLOOR PLAN - LEVEL 4 - EAST ENLARGED
PLUMBING FLOOR PLAN - LEVEL 6 - EAST ENLARGED
PLUMBING FLOOR PLAN - LEVEL 7 - EAST ENLARGED
NTSP-50-01
P-50-02
P-50-03
PLUMBING SANITARY RISER DIAGRAM
PLUMBING DOMESTIC WATER RISER DIAGRAM
PLUMBING STORM RISER DIAGRAM
19 NTS
0 - -
N.T.S.
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:0 P
M
P-00-01
NOTES, SYMBOLS, & ABBREVIATIONS
Author
Checker
D D
C C
C C
D D
RESTROOM (W)
3CWMN
COPY
3B102
FOCUS ROOM
3C257
RESTROOM (M)
3CMEN
JANITOR
3CJA
DISCONNECT AND REMOVE ONE (1) LAVATORY. CUT
AND CAP ROUGH-INS
DISCONNECT AND REMOVE ONE (1) SINK. CUT
AND CAP ROUGH-INS
D D
C C
C C
D D
RESTROOM (W)
3AWMN
WEST PANTRY
3APN
COPY
3A203
CONFERENCE
3A150
HUDDLE ROOM
3A251
RESTROOM (M)
3AMEN
JANITOR
3AJA1
DISCONNECT AND REMOVE ONE (1)
LAVATORY. CUT AND CAP ROUGH-INS
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:1 A
M
PD-13-01
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 3 - EAST &
WEST
Author
Checker
3/8" = 1'-0"
PLUMBING_LEVEL 3_FLOOR
PLAN_DEMO EAST
3/8" = 1'-0"
PLUMBING_LEVEL 3_FLOOR
PLAN_DEMO WEST
D D
C C
C C
D D
RESTROOM (W)
4CWMN
EAST PANTRY
4BPN
COPY
4B102
FOCUS ROOM
4C257
RESTROOM (M)
4CMEN
JANITOR
4CJA
DISCONNECT AND REMOVE ONE (1) LAVATORY. CUT
AND CAP ROUGH-INS
DISCONNECT AND REMOVE ONE (1) SINK. CUT
AND CAP ROUGH-INS
D D
C C
C C
D D
RESTROOM (W)
4AWMN
RESTROOM (M)
4AMEN
JANITOR
4AJA1
MOTHER'S ROOM
4AMRM
DISCONNECT AND REMOVE ONE (1)
LAVATORY. CUT AND CAP ROUGH-INS
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:1 A
M
PD-14-01
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 4 - EAST &
WEST
Author
Checker
3/8" = 1'-0"
PLUMBING_LEVEL 4_FLOOR
PLAN_DEMO EAST
3/8" = 1'-0"
PLUMBING_LEVEL 4_FLOOR
D D
C C
C C
D D
RESTROOM (W)
6CWMN
EAST PANTRY
6BPN
COPY
6B102
FOCUS ROOM
6C257
RESTROOM (M)
6CMEN
JANITOR
6CJA
DISCONNECT AND REMOVE ONE (1) LAVATORY. CUT
AND CAP ROUGH-INS
DISCONNECT AND REMOVE ONE (1) SINK. CUT
AND CAP ROUGH-INS
D D
C C
C C
D D
RESTROOM (W)
6AWMN
RESTROOM (M)
6AMEN
JANITOR
6AJA1
MOTHER'S ROOM
6AMRM
DISCONNECT AND REMOVE ONE (1)
LAVATORY. CUT AND CAP ROUGH-INS
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:1
:0 A
M
PD-16-01
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 6 - EAST &
WEST
Author
Checker3/8" = 1'-0"
PLUMBING_LEVEL 6_FLOOR
PLAN_DEMO EAST
3/8" = 1'-0"
PLUMBING_LEVEL 6_FLOOR
D D
C C
C C
D D
RESTROOM (W)
7CWMN
EAST PANTRY
7CPN
COPY
7B102
FOCUS ROOM
7C255
RESTROOM (M)
7CMEN
JANITOR
7CJA
DISCONNECT AND REMOVE ONE (1) LAVATORY. CUT
AND CAP ROUGH-INS
DISCONNECT AND REMOVE ONE (1) SINK. CUT
AND CAP ROUGH-INS
D D
C C
C C
D D
RESTROOM (W)
7AWMN
RESTROOM (M)
7AMEN
JANITOR
7AJA1
MOTHER'S ROOM
7AMRM
DISCONNECT AND REMOVE ONE (1)
LAVATORY. CUT AND CAP ROUGH-INS
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:1
:0 A
M
PD-17-01
PLUMBING DEMOLITION FLOOR PLAN - LEVEL 7 - EAST &
WEST
Author
Checker
3/8" = 1'-0"
PLUMBING_LEVEL 7_FLOOR
PLAN_DEMO EAST
3/8" = 1'-0"
PLUMBING_LEVEL 7_FLOOR
FEC
F E
C
FEC
F E
C
FEC
F E
C
FEC
F E
C
F E
C
F E
C F
E C
F E
C
FEC
F E
C
FECFEC
F E
C
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO ENLARGED PLAN
P-13-01 FOR PLUMBING SCOPE
IN THIS AREA
REFER TO ENLARGED PLAN
P-13-02 FOR PLUMBING
SCOPE IN THIS AREA
0 16' 32'
1/16"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:3
:5 A
M
P-13-00
PLUMBING FLOOR PLAN - LEVEL 3 - OVERALL
Author
Checker
1/16" = 1'-0"
PLAN_OVERALL
FECFEC
FEC
D D
C C
C C
D D
RESTROOM (W)
3CWMN
FOCUS ROOM
3C257
RESTROOM (M)
3CMEN
JANITOR
3CJA
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS, AND
ALL RELATED ITEMS FOR A COMPLETE INSTALLATION
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS,
CHAIR CARRIERS, AND ALL RELATED ITEMS FOR A
COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS FOR
A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND CW PIPING IN
CHASE
NEW 2" FUNNEL DRAIN BELOW SINK
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V, 1 PHASE.
SPILL T&P RELIEF TO FUNNEL DRAIN BELOW SINK.
PROVIDE LEAK DETECTION ON COLD WATER SUPPLY
TO HEATER
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-OFF
VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK VALVE
FD
HB
FD
HB
COWP
COWP
COWP
COWP
COWP
COWP
COWP
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
PROVIDE CLEANOUT WALL PLATES AT END OF SANITARY
PIPING RUNS (TYPICAL)
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
DF DF
DF DF
LAV
LAV
LAV
LAV
LAV
LAV
LAV
UR
UR
UR
EXISTING FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR
EXISTING FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR
SK
D D
C C
C C
D D
RESTROOM (W)
3AWMN
WEST PANTRY
3APN
COPY
3A203
RESTROOM (M)
3AMEN
JANITOR
3AJA1
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO
NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS
FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH
NEW. CONNECT TO EXISTING ROUGH-INS AND EXTEND
TO NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED
TO ACCOMMODATE NEW FIXTURES. PROVIDE AND
INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS,
AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR
CARRIERS, AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
NEW LAVATORY
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT AND CW PIPING IN
CHASE. EXTEND HW PIPING AT CEILING TOWARDS
RESTROOM LAVATORIES 3AWMN AND CONNECT TO
EXISTING HW PIPING
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND
CW PIPING IN CHASE
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V,
1 PHASE. SPILL T&P RELIEF TO FUNNEL
DRAIN BELOW SINK. PROVIDE LEAK
DETECTION ON COLD WATER SUPPLY TO
HEATER
NEW 2" FUNNEL DRAIN BELOW SINK
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-
OFF VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK
VALVE
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
HB
FD
HB
FD
COWP
COWP
COWP
COWP
COWP
COWP
PROVIDE CLEANOUT WALL PLATES AT END OF
SANITARY PIPING RUNS (TYPICAL)
COWP
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
SK
LAV
DF DF
DF DF
UR
UR
UR
LAV
LAV
LAV
LAV
LAV
LAV
EXISTING FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR
EXISTING FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:3
:0 A
M
P-13-01
PLUMBING FLOOR PLAN - LEVEL 3 - EAST WEST
Author
Checker
3/8" = 1'-0"
PLUMBING_LEVEL 3_FLOOR
PLAN__EAST
3/8" = 1'-0"
PLAN__WEST
F E
C
FEC
F E
C
FEC
F E
C
FEC
F E
C
F E
C
F E
C F
E C
F E
C
FEC
F E
C
FECFEC
F E
C
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO ENLARGED PLAN
P-14-01 FOR PLUMBING SCOPE
IN THIS AREA
REFER TO ENLARGED PLAN
P-14-02 FOR PLUMBING
SCOPE IN THIS AREA
0 1' 2'
1 1/2"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:4
:0 A
M
P-14-00
PLUMBING FLOOR PLAN - LEVEL 4 - OVERALL
Author
Checker
1/16" = 1'-0"
FEC
FEC
D D
C C
C C
D D
RESTROOM (W)
4CWMN
EAST PANTRY
4BPN
COPY
4B102
FOCUS ROOM
4C257
RESTROOM (M)
4CMEN
JANITOR
4CJA
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS, AND
ALL RELATED ITEMS FOR A COMPLETE INSTALLATION
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS,
CHAIR CARRIERS, AND ALL RELATED ITEMS FOR A
COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS FOR
A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND CW PIPING IN
CHASE
NEW 2" FUNNEL DRAIN BELOW SINK
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V, 1 PHASE.
SPILL T&P RELIEF TO FUNNEL DRAIN BELOW SINK.
PROVIDE LEAK DETECTION ON COLD WATER SUPPLY
TO HEATER
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-OFF
VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK VALVE
FD
HB
FD
HB
COWP
COWP
COWP
COWP
COWP
COWP
COWP
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
PROVIDE CLEANOUT WALL PLATES AT END OF SANITARY
PIPING RUNS (TYPICAL)
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
LAV
LAV
LAV
LAV
LAV
LAV
LAV
DF DF
DF DF
UR
UR
UR
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
SK
D D
C C
C C
D D
RESTROOM (W)
4AWMN
WEST PANTRY
4APN
COPY
4A203
RESTROOM (M)
4AMEN
JANITOR
4AJA1
MOTHER'S ROOM
4AMRM
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO
NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS
FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH
NEW. CONNECT TO EXISTING ROUGH-INS AND EXTEND
TO NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED
TO ACCOMMODATE NEW FIXTURES. PROVIDE AND
INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS,
AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR
CARRIERS, AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
NEW LAVATORY
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT AND CW PIPING IN
CHASE. EXTEND HW PIPING AT CEILING TOWARDS
RESTROOM LAVATORIES 4AWMN AND CONNECT TO
EXISTING HW PIPING
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND
CW PIPING IN CHASE
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V,
1 PHASE. SPILL T&P RELIEF TO FUNNEL
DRAIN BELOW SINK. PROVIDE LEAK
DETECTION ON COLD WATER SUPPLY TO
HEATER
NEW 2" FUNNEL DRAIN BELOW SINK
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-
OFF VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK
VALVE
VESTIBULE
4A2VES
VESTIBULE
4A1VES
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
HB
FD
HB
FD
COWP
COWP
COWP
COWP
COWP
COWP
PROVIDE CLEANOUT WALL PLATES AT END OF
SANITARY PIPING RUNS (TYPICAL)
COWP
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
LAV
DF DF
DF DF
LAV
LAV
LAV
LAV
LAV
LAV
LAV
UR
UR
UR
EXISTIN FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR.
EXISTIN FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR.
SK
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:4
:0 A
M
P-14-01
PLUMBING FLOOR PLAN - LEVEL 4 - EAST & WEST
Author
Checker
3/8" = 1'-0"
PLUMBING_LEVEL 4_FLOOR
PLAN__EAST
3/8" = 1'-0"
F E
C
F E
C
F E
C F
E C
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
20a
20a
A A
B B
C C
D D
E E
F F
20a
20a
RESTROOM (W)
4CWMN
STAIR 4
4CST
Room
EAST PANTRY
4BPN
COPY
4B102
OFFICE
4C111
OFFICE
4C112
OFFICE
4C110
OFFICE
4C114
OFFICE
4C113
OFFICE
4C115
OFFICE
4C211
OFFICE
4C212
OFFICE
4C214
OFFICE
4C213
OFFICE
4C215
CONFERENCE
4C156
CONFERENCE
4C150
HUDDLE ROOM
4C251
HUDDLE ROOM
4C151
FOCUS
4C153
FOCUS
4C152
FOCUS
4C253
FOCUS
4C252
FOCUS
4C255
FOCUS
4C155
FOCUS
4C154
FOCUS
4C254
CONFERENCE
4C256
FOCUS ROOM
4C257
RESTROOM (M)
4CMEN
JANITOR
4CJA
ELECTRICAL
4CEL2
Room
TELECOM
4CTL2
Room
TELECOM
4CTL1
ELECTRICAL
4CEL1
OFFICE
4C192
OFFICE
4C191
OFFICE
4C190
OFFICE
4C292
OFFICE
4C291
OFFICE
4C2904" S UP
4"
CONNECT NEW SANITARY
PIPING TO EXISTING STACK IN
RESTROOM
4"
0 8' 16'
1/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:4
:4 A
M
P-14-02
PLUMBING FLOOR PLAN - LEVEL 4 - ENLARGED EAST
Author
Checker
1/8" = 1'-0"
PLAN_ENLARGED EAST
F E
C
FEC
F E
C F
E C
FEC
FEC
F E
C
FEC
FEC
F E
C
F E
C
FEC
F E
C F
E C
F E
C
F E
C
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO ENLARGED PLAN
P-16-01 FOR PLUMBING SCOPE
IN THIS AREA
REFER TO ENLARGED PLAN
P-16-02 FOR PLUMBING
SCOPE IN THIS AREA
0 16' 32'
1/16"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:5
:0 A
M
P-16-00
PLUMBING FLOOR PLAN - LEVEL 6 - OVERALL
Author
Checker
1/16" = 1'-0"
FEC
FEC
D D
C C
C C
D D
RESTROOM (W)
6CWMN
EAST PANTRY
6BPN
COPY
6B102
FOCUS ROOM
6C257
RESTROOM (M)
6CMEN
JANITOR
6CJA
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS, AND
ALL RELATED ITEMS FOR A COMPLETE INSTALLATION
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS,
CHAIR CARRIERS, AND ALL RELATED ITEMS FOR A
COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS FOR
A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND CW PIPING IN
CHASE
NEW 2" FUNNEL DRAIN BELOW SINK
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V, 1 PHASE.
SPILL T&P RELIEF TO FUNNEL DRAIN BELOW SINK.
PROVIDE LEAK DETECTION ON COLD WATER SUPPLY
TO HEATER
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-OFF
VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK VALVE
FD
HB
FD
HB
COWP
COWP
COWP
COWP
COWP
COWP
COWP
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
PROVIDE CLEANOUT WALL PLATES AT END OF SANITARY
PIPING RUNS (TYPICAL)
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
DF DF
DF DF
LAV
LAV
LAV
LAV
LAV
LAV
LAV
UR
UR
UR
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
SK
D D
C C
C C
D D
RESTROOM (W)
6AWMN
WEST PANTRY
6APN
COPY
6A203
RESTROOM (M)
6AMEN
JANITOR
6AJA1
MOTHER'S ROOM
6AMRM
VESTIBULE
6A2VES
VESTIBULE
6A1VES
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO
NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS
FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH
NEW. CONNECT TO EXISTING ROUGH-INS AND EXTEND
TO NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED
TO ACCOMMODATE NEW FIXTURES. PROVIDE AND
INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS,
AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR
CARRIERS, AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES. PROVIDE
AND INSTALL NEW TRIM, TRAP, FITTINGS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
NEW LAVATORY
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT AND CW PIPING IN
CHASE. EXTEND HW PIPING AT CEILING TOWARDS
RESTROOM LAVATORIES 3AWMN AND CONNECT TO
EXISTING HW PIPING
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND
CW PIPING IN CHASE
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V,
1 PHASE. SPILL T&P RELIEF TO FUNNEL
DRAIN BELOW SINK. PROVIDE LEAK
DETECTION ON COLD WATER SUPPLY TO
HEATER
NEW 2" FUNNEL DRAIN BELOW SINK
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-
OFF VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK
VALVE
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
HB
FD
HB
FD
COWP
COWP
COWP
COWP
COWP
COWP
PROVIDE CLEANOUT WALL PLATES AT END OF
SANITARY PIPING RUNS (TYPICAL)
COWP
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
LAV
DF DF
LAV
LAV
LAV
LAV
LAV
LAV
LAV
UR
UR
UR
DF DF
EXISTIN FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR.
EXISTIN FLOOR DRAIN LOCATION TO
REMAIN. PROVIDE NEW DRAIN BODY AND
GRATE TO ACCOMMODATE NEW FLOOR.
SK
0 4' 8'
3/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:0 A
M
P-16-01
PLUMBING FLOOR PLAN - LEVEL 6 - EAST & WEST
Author
Checker 3/8" = 1'-0"
PLUMBING_LEVEL 6_FLOOR
PLAN__EAST
3/8" = 1'-0"
F E
C F
E C
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
20a
20a
A A
B B
C C
D D
E E
F F
20a
20a
STAIR 4
6CST
OFFICE
6C115
OFFICE
6C215
ELECTRICAL
6CEL2
TELECOM
6CTL2
TELECOM
6CTL1
ELECTRICAL
6CEL1
OFFICE
6C192
OFFICE
6C191
OFFICE
6C292
OFFICE
6C291
OFFICE
6C290
OFFICE
6C294
4"
4"
4"
4"
4" S UP TO BATHROOM
4" S UP TO BATHROOM
4" S DN. 4" PIPING PASSES THROUGH
5TH FLOOR WITHIN SHAFT AND
OFFSETS ON 4TH FLOOR. REFER TO
DRAWING P-14-03 FOR CONTINUATION
2"
2" S UP TO PANTRY
OFFICE
6C293
CONFERENCE
6C160
ASSISTANT SECRETARY'S
SUITE
6C181
CORRIDOR
6C102
OFFICE
6C193
OFFICE
6C194
OFFICE
6C295
Room
3C177
Room
3C182
Room
3C183
3" S UP TO FD
3" S UP TO FD
0 8' 16'
1/8"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:1 A
M
P-16-02
PLUMBING FLOOR PLAN - LEVEL 6 - ENLARGED EAST
Author
Checker
1/8" = 1'-0"
PLAN_ENLARGED EAST
C
F E
C F
E C
FEC
FEC
F E
C
FEC
FEC
F E
C F
E C
FEC
FEC
F E
C
FEC
FEC
F E
C
F E
C
F E
C
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO ENLARGED PLAN
P-17-01 FOR PLUMBING SCOPE
IN THIS AREA
REFER TO ENLARGED PLAN
P-17-02 FOR PLUMBING
SCOPE IN THIS AREA
0 16' 32'
1/16"=1'-0"
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
F
IC
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
T
IO
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
PLUMBING/FIRE PROTECTION
VARIES, SEE DRAWINGS
01 04/23/2020 ISSUED FOR BID
04/23/2021
2020-2021
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
/2
/2
:0
:2 A
M
P-17-00
PLUMBING FLOOR PLAN - LEVEL 7 - OVERALL
Author
Checker
1/16" = 1'-0"
FEC
FEC
D D
C C
C C
D D
REMOVE AND REPLACE EXISTING DRINKING FOUNTAIN
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS, AND
ALL RELATED ITEMS FOR A COMPLETE INSTALLATION
IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW. CONNECT TO EXISTING ROUGH-INS AND
EXTEND TO NEW FIXTURE. MODIFY ROUGH-INS AS
REQUIRED TO ACCOMMODATE NEW FIXTURES.
PROVIDE AND INSTALL NEW TRIM, TRAP, FITTINGS,
CHAIR CARRIERS, AND ALL RELATED ITEMS FOR A
COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS, AND ALL
RELATED ITEMS FOR A COMPLETE INSTALLATION IN
ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO NEW
FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS FOR
A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
NEW PANTRY SINK
2" S
2" V
1/2" CW&HW
CONNECT TO EXISTING SAN, VENT, AND CW PIPING IN
CHASE
NEW 2" FUNNEL DRAIN BELOW SINK
NEW ELECTRIC WATER HEATER AT CEILING
AO SMITH DEL-10-3, 10 GALLON, 3KW, 208V, 1 PHASE.
SPILL T&P RELIEF TO FUNNEL DRAIN BELOW SINK.
PROVIDE LEAK DETECTION ON COLD WATER SUPPLY
TO HEATER
NEW REFRIGERATOR WITH ICE MAKER
1/2" FILTERED CW CONNECTION WITH SHUT-OFF
VALVE AND DUAL CHECK VALVE
NEW CONNECTION FOR FUTURE COFFEE
MAKER
1/2" FILTERED CW WITH SHUT-OFF VALVE,
VACUUM BREAKER, AND DUAL CHECK VALVE
FD
HB
FD
HB
COWP
COWP
COWP
COWP
COWP
COWP
COWP
NEW 3/4" HOSE BIBB BELOW LAVATORIES (TYPICAL)
PROVIDE CLEANOUT WALL PLATES AT END OF SANITARY
PIPING RUNS (TYPICAL)
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
WC
LAV
LAV
LAV
LAV
LAV
LAV
LAV
UR
UR
UR
SK
DF DF
DF DF
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
EXISTIN FLOOR DRAIN LOCATION TO REMAIN.
PROVIDE NEW DRAIN BODY AND GRATE TO
ACCOMMODATE NEW FLOOR.
D D
C C
C C
D D
REMOVE AND REPLACE EXISTING URINALS WITH NEW.
CONNECT TO EXISTING ROUGH-INS AND EXTEND TO
NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED TO
ACCOMMODATE NEW FIXTURES. PROVIDE AND INSTALL
NEW TRIM, TRAP, FITTINGS, AND ALL RELATED ITEMS
FOR A COMPLETE INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING LAVATORIES WITH
NEW. CONNECT TO EXISTING ROUGH-INS AND EXTEND
TO NEW FIXTURE. MODIFY ROUGH-INS AS REQUIRED
TO ACCOMMODATE NEW FIXTURES. PROVIDE AND
INSTALL NEW TRIM, TRAP, FITTINGS, CHAIR CARRIERS,
AND ALL RELATED ITEMS FOR A COMPLETE
INSTALLATION IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS. (TYPICAL)
REMOVE AND REPLACE EXISTING WATER CLOSETS
WITH NEW.
This is the start of the file's text. The full file is on GovTribe.