Drawing - FA.pdf
PDF 20 MB Posted
- Attached to
- Solicitation Notice - LBJ Consolidation & Switchgear Federal contract opportunity
- Solicitation number
- 47PM0121R0013
About this file
This document provides details of a solicitation notice for construction services related to the LBJ Consolidation Construction & Switchgear project. The General Services Administration Public Buildings Service is seeking a single firm fixed price contract to perform repair, alteration, and construction services including interior alterations and open workspace construction as well as significant renovations to the major switchgear and electrical systems servicing the building. Services will renovate floors 3, 4, 6, & 7 totaling approximately 198,369 square feet of existing office space and 10,000 square feet of bathrooms to reconstructed open office and meeting spaces. The project aims to improve utilization of the LBJ Building and allow the Department of Education to add approximately 600 employees from leased spaces into the building. The solicitation number is 47PM0121R0013 and the North American Industry Classification System code is 236220. The small business size standard is $39.5 million in average annual receipts. The pre-proposal conference will be held virtually on May 5, 2021 and proposals are due by June 4, 2021. The solicitation and any amendments will be posted at SAM.gov.
View the file
Other files for this federal contract opportunity
Show all 50
Solicitation Notice - LBJ Consolidation & Switchgear has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNTED
SMOKE DETECTOR, DUCT MOUNTED
SMOKE DETECTOR, PHOTOELECTRIC, ELEVATOR LOBBY,
CEILING MOUNTED
HEAT DETECTOR, RATE OF RISE
MANUAL PULL STATION
WATERFLOW SWITCH
TAMPER SWITCH
VISUAL ALARM SIGNAL, WALL MOUNTED
# INDICATES CANDELA RATING (15cd UON)
VISUAL ALARM SIGNAL, CEILING MOUNTED
# INDICATES CANDELA RATING (15cd UON)
CONDUIT
MONITORING MODULE
FIRE ALARM CONTROL PANEL
REMOTE FIRE ALARM CONTROL PANEL
FIRE ALARM TERMINAL CABINET
FIRE ALARM REMOTE ANNUNCIATOR
DATA GATHERING PANEL
NOTIFICATION APPLIANCE CIRCUIT POWER SUPPLY
ELECTRIC MOTOR
RELAY - FIRE ALARM
BUILDING MANAGEMENT SYSTEM
AIR HANDLING UNIT
VARIABLE FREQUENCY DRIVE
DISCONNECT SWITCH
FIRE ALARM LEGEND
- UNLESS OTHERWISE NOTED
- SECONDS
- POLYVINYL CHLORIDE
- SYMMETRICAL
- TELEPHONE TERMINAL BOARD
- WEATHER PROOF
- RIGID GALVANIZED STEEL
- RECEPTACLE
- TRANSFORMER
- VOLT AMPERES
LTG - LIGHTING
- CIRCUITCKT
- VOLTAGEV
- PHASE
- NOT TO SCALE
- NOT IN CONTRACT
- NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
- NON-FUSED SAFETY SWITCH
- MOUNTING HEIGHT
- MAIN LUGS ONLY
- MANHOLE
- MECHANICAL
- MAIN DISTRIBUTION PANEL
- MOTOR CIRCUIT PROTECTOR
- MAIN CIRCUIT BREAKER
- NATIONAL ELECTRICAL CODE
- FULL LOAD AMPERES
- FUSED OR FUSIBLE
- EXISTING TO REMAIN
- ELECTRICAL METALLIC TUBING
- CURRENT TRANSFORMER
- ELECTRIC/ ELECTRICAL
- FIRE ALARM CONTROL PANEL
- ELECTRIC WATER COOLER
ETR
FACP
FO
FLA
EX, EXIST
EWC
F
- FIBER OPTIC
- EXISTING
EF
EQUIP
ELEC
EMT
DWG
CT
CLG
- EXHAUST FAN
- EQUIPMENT
- DRAWING
- CEILING
NEC
NTS
PH
NFSS
NIC
NEMA
MECH
MLO
MT HT
MH
MCP
MDP
MCB
XFMR
W
WP
VA
- WIRE
- THOUSAND CIRCULAR MILS
- JUNCTION BOX
- HAND-OFF-AUTOMATIC
- GROUND FAULT CIRCUIT INTERRUPTER
- GROUND WIRE
- KILOVAR HOUR
- GROUND
- KILOVOLT-AMPERES
- HERTZ
- HORSE POWER
- GOVERNMENT FURNISHED EQUIPMENT
ABBREVIATIONS
- CIRCUIT BREAKER
- AMPERE INTERRUPTING CAPACITY
- ABOVE FINISHED GRADE
- AIR HANDLING UNIT
- AMERICAN WIRE GAUGE
- AUTOMATIC TRANSFER SWITCH
- ABOVE FINISHED FLOOR
AHU
AWG
BLDG
C
CB
ASYM
ATS
AIC
- BUILDING
- CONDUIT
- ASYMMETRICAL
A
AFF
AFG
ACT
- AMPERES
- ACOUSTICS TILE
GW
JB
KVA
KVARH
KCMIL
HP
HZ
HOA
GFE
GND
GFCI
RGS
TEL
UON
TTB
TYP
SEC
RM
SYM
- TELEPHONE
- TYPICAL
- ROOM
P
PNL
PVC
RECPT
- POLE
- PANEL
MTS - MANUAL TRANSFER SWITCH
- POTENTIAL TRANSFORMERPT
CR - CONTROL RELAY
- KILOWATTKW
- KILOWATT HOURKWH
- POWER FACTORPF
- COPPERCU
- HANDHOLEHH
- KILOVOLT AMP REACTIVEKVAR
- FUSED SAFETY SWITCHFSS
- WITHW/
- SHUNT CLOSESC
- SHUNT TRIPST
- MINUTESMIN
TR - TELEPHONE ROOM
GFGI - GOVERNMENT FURNISHED GOVERNMENT INSTALLED
CFCI - CONTRACTOR FURNISHED
CONTRACTOR INSTALLED
- CONTRACTOR FURNISHED
GOVERNMENT INSTALLED
CFGI
OR GOVERNMENT FURNISHED CONTRACTOR INSTALLED
MOV - METAL OXIDE VARISTOR
- UNITED STATES GOVERNMENTUSG
MM
M
W
FIRE ALARM GENERAL NOTES
E
P
NAC
DGP
FATC
FARA
RFCP
FACP
BMS
AHU
VFD
R
T
COMBINATION SPEAKER / STROBE, WALL MOUNTED
# INDICATES CANDELA RATING (15cd UON)
COMBINATION SPEAKER / STROBE, CEILING MOUNTED
# INDICATES CANDELA RATING (15cd UON)
S
S
FIRE FIGHTER'S PHONEFP
1. INSTALLATION OF NEW FIRE ALARM SYSTEM SHALL BE COMPLETED IN ACCORDANCE WITH THE IBC, GSA P-100, NFPA, NEC, ASHRAE 90.1 AND THE AUTHORITY HAVING JURISDICTION (AHJ). REFER TO CONTRACT DOCUMENTS
FOR VERSIONS APPROPRIATE FOR THIS PROJECT.
2. FIRE ALARM PLANS ARE DIAGRAMMATIC ONLY. CONTRACTOR SHALL COORDINATE LOCATION OF DEVICES IN THE
FIELD WITH EXISTING CONDITIONS.
3. SOME SYMBOLS SHOWN ON THIS SHEET MAY NOT BE USED ON THIS PROJECT. SYMBOLS SHOWN ON THIS SHEET
IS A STANDARD COMPANY PRACTICE.
4. ALL NEW WORK SHALL BE CONCEALED IN CEILINGS, WALLS, ETC. U.O.N. REFER TO ARCHITECTURAL PLANS FOR
CEILING AND WALL TYPES.
5. COORDINATE ALL FIRE ALARM EQUIPMENT WITH ALL OTHER TRADES TO AVOID CONFLICTS. PROVIDE ALL NECESSARY FITTINGS, EQUIPMENT, HANGERS, OFFSETS, ROUTING, ETC. TO AVOID CONFLICTS.
6. MAINTAIN CONTINUITY OF SLC AND NAC CIRCUITS TO REMAIN SERVING AREAS OUTSIDE OF CONSTRUCTION AREA. REPLACE FIRE ALARM WIRING AND RACEWAY TO MATCH EXISTING. DO NOT SPLICE CONDUCTORS.
7. FIRE ALARM SYSTEM OPERATION SHALL MATCH THE EXISTING BUILDING SYSTEM.
8. MAINTAIN SYNCHRONIZATION OF ALL STROBES WHEN SYSTEM IS REPLACED.
9. THE AHJ IS THE GSA REGIONAL FIRE PROTECTION ENGINEER.
10. TEST ALL EXISTING DEVICES WITHIN THE BUILDING AND REPORT ANY DEFICIENCIES TO THE AHJ. DEVICES WHICH ARE NOT FUNCTIONING PROPERLY SHALL BE ADDRESSED AT THE DISCRETION OF THE AHJ AND GSA.
11. ALL NEW CIRCUITS OR PATHWAYS MUST BE SIMILAR IN CLASS AND STYLE TO THE EXISTING CIRCUITS OR
PATHWAYS. PERFORMANCE FEATURES MUST BE MAINTAINED.
12. SHOP DRAWING DESIGN SHALL BE PROVIDED BY A NICET LEVEL III OR IV FIRE ALARM TECHNICIAN OR A REGISTERED FIRE PROTECTION ENGINEER. INSTALLATION SHALL BE ACCOMPLISHED BY AN ELECTRICAL
CONTRACTOR WITH A MINIMUM OF FIVE YEARS EXPERIENCE IN THE INSTALLATION OF FIRE ALARM SYSTEMS.
13. CONDUCTORS MUST MATCH EXISTING IN GAUGE, TYPE AND COLOR CODING. ALL CONDUCTORS WHICH ARE TERMINATED, SPLICED, OR OTHERWISE INTERRUPTED IN ANY ENCLOSURE, CABINET, MOUNTING OR JUNCTION
BOX SHALL BE CONNECTED TO TERMINAL BLOCKS. USE OF WIRE NUTS IS PROHIBITED.
14. INSTALL ALL CONDUCTORS IN RIGID METAL CONDUIT OR ELECTRICAL-METALLIC TUBING, WITH A MINIMUM
;DIAMETER OF 3/4". RUN CONDUIT OR TUBING CONCEALED UNLESS SPECIFICALLY SHOWN OTHERWISE ON THE DRAWINGS. ALL WIRING FOR THE FIRE ALARM SYSTEM MUST BE INSTALLED IN SEPARATE CONDUIT. NO OTHER
BUILDING WIRING IS PERMITTED IN CONDUIT THAT CONTAINS FIRE ALARM WIRING.
15. THE GSA FIRE ALARM SHOP (FAS), (301)-636-1744, MUST BE CONTACTED TO SCHEDULE AND OUTAGE BEFORE
ANY WORK WHICH COULD AFFECT THE FIRE ALARM SYSTEM, IS PERMITTED.
16. NO FIRE ALARM CIRCUIT TIE-IN IS PERMITTED WITHOUT GSA FIRE ALARM SHOP PRESENCE.
17. WHEN THE CONTACTOR WORKS ON THE FIRE ALARM CIRCUITS, THE SYSTEM MUST BE TAKEN OUT-OF-SERVICE
BY THE GSA FAS, AND THE SYSTEM MUST BE RETURNED TO "NORMAL" BEFORE THE
ELECTRICIANS/CONTRACTORS LEAVE FOR THE DAY.
18. FIRE ALARM PROGRAMMING CHANGES ARE PERMITTED ONLY WHEN CONFIRMED ACCEPTANCE TESTING IS SCHEDULED WITH THE AHJ. A FIRE ALARM PROGRAM CHANGE MUST BE ACCEPTANCE TESTED WITHIN 24 HOURS
OF THE CHANGE.
19. SUBMIT SHOP DRAWINGS (NOT SMALLER THAN 36" x 48") AND, AS A MINIMUM, SHALL INCLUDE THE FOLLOWING:
a. POINT-TO-POINT WIRING DIAGRAMS SHOWING THE POINTS OF CONNECTION AND TERMINALS USED FOR ALL
ELECTRICAL FIELD CONNECTIONS IN THE SYSTEM, INCLUDING ALL INTERCONNECTIONS BETWEEN THE
EQUIPMENT OR SYSTEMS WHICH ARE SUPERVISED OR CONTROLLED BY THE SYSTEM.
b. INCLUDE ANNOTATED CATALOG DATA SHOWING MANUFACTURER'S NAME, MODEL, VOLTAGE, AND CATALOG
NUMBERS FOR ALL EQUIPMENT AND COMPONENTS.
c. PROVIDE CALCULATIONS SHOWING THAT NO INDIVIDUAL NOTIFICATION CIRCUIT IS LOADED BEYOND 80% OF
ITS FULL LOAD CAPACITY.
d. INCLUDE BATTERY CALCULATIONS FOR BOTH THE ALARM AND SUPERVISORY POWER REQUIREMENTS.
AMPERE-HOUR REQUIREMENTS FOR EACH SYSTEM COMPONENT SHALL BE SUBMITTED WITH THE
CALCULATIONS.
d.a. CAPACITY: PROVIDE THE BATTERIES WITH SUFFICIENT CAPACITY TO OPERATE ALL SIGNALING LINE
CIRCUITS, INITIATING DEVICES CIRCUITS, AND NOTIFICATION APPLIANCE CIRCUITS IN NORMAL OR SUPERVISORY (NON-ALARM) MODE FOR A PERIOD OF 24 HOURS. FOLLOWING THIS PERIOD OF OPERATION
ON BATTERY POWER, THE BATTERIES SHALL HAVE SUFFICIENT CAPACITY TO OPERATE ALL
COMPONENTS OF THE SYSTEM IN ALARM MODE FOR A PERIOD OF FIFTEEN (15) MINUTES. BATTERY CAPACITY CALCULATIONS SHALL BE BASED ON EQUIPMENT CURRENT DRAW AT A MINIMUM OPERATING
VOLTAGE OF 24 VDC. PROVIDE BATTERIES SIZED AT 150% OF FIRE ALARM MANUFACTURER'S
CALCULATION.
e. PROVIDE A COLOR CODE SCHEDULE FOR THE WIRING AND FLOOR PLANS SHOWING LOCATION OF ALL
DEVICES AND EQUIPMENT.
f. THE SIGNATURE AND SEAL OF A REGISTERED PROFESSIONAL FIRE PROTECTION ENGINEER, REGISTERED
PROFESSIONAL ENGINEER WITH A MINIMUM OF TWO YEARS FIRE PROTECTION DESIGN EXPERIENCE, OR A
NICET LEVEL III OR IV TECHNICIAN.
20. PRELIMINARY TESTING: CONDUCT PRELIMINARY TESTS TO ENSURE THAT ALL DEVICES AND CIRCUITS ARE
FUNCTIONING PROPERLY. AFTER PRELIMINARY TESTING IS COMPLETE, PROVIDE A LETTER CERTIFYING THAT THE INSTALLATION IS COMPLETE AND FULLY OPERABLE. THE LETTER SHALL STATE THAT EACH INITIATING AND
INDICATING DEVICE WAS TESTED IN PLACE AND FUNCTIONED PROPERLY. THE LETTER SHALL INCLUDE THE NAMES AND TITLES OF THE WITNESSES TO THE PRELIMINARY TESTS. THE CONTRACTOR AND AN AUTHORIZED REPRESENTATIVE FROM EACH SUPPLIER OF EQUIPMENT SHALL BE IN ATTENDANCE AT THE PRELIMINARY
TESTING TO MAKE NECESSARY ADJUSTMENTS. A MEMBER OF THE GSA FIRE ALARM SHOP MUST BE INVITED TO
THE PRELIMINARY TEST.
21. FINAL TESTING: NOTIFY THE CONTRACTING OFFICER IN WRITING WHEN THE SYSTEM IS READY FOR FINAL ACCEPTANCE TESTING. SUBMIT THE REQUEST FOR TESTING AT LEAST 15 CALENDAR DAYS PRIOR TO TEST DATE. THE FINAL TESTS SHALL BE WITNESSED BY A MEMBER OF THE GSA SAFETY ENVIRONMENT AND FIRE
PROTECTION BRANCH AND THE GSA FIRE ALARM SHOP. AT THIS TIME, ANY AND ALL REQUIRED TESTS SHALL BE
REPEATED AT THE DISCRETION OF THE GOVERNMENT.
22. SUBMIT AS-BUILT DRAWINGS TO THE CONTRACTING OFFICER UPON COMPLETION OF THE PROJECT. THESE
DRAWINGS SHALL INDICATE CHANGES FROM THE ORIGINAL LAYOUT, MARKED IN RED.
23. ALL PENETRATIONS THROUGH THE RATED PARTITIONS IN THE BUILDING CORE AND FLOOR SLABS SHALL BE PROVIDED WITH FIRESTOPPING AT PENETRATIONS IN ACCORDANCE WITH THE UL LISTED DETAILS IN THIS
PROJECT.
TRANSPONDER/AMPLIFIER CABINETAMP
REMOTE LAMPRL
SCOPE OF WORK NOTES:
FIRE ALARM – THE FIRE ALARM SYSTEM IS AN EXISTING
FUNCTIONAL SYSTEM AND MODIFICATIONS IS BEING DONE TO 4
FLOORS AS PART OF THIS PROJECT. AS PART OF DEMOLITION,
ALL EXISTING FIRE ALARM FLOOR DEVICES, INCLUDING DUCT
DETECTORS, TAMPER AND FLOW SWITCHES RELAY
MONITORING, ALL EXISTING CONDUIT AND WIRING ETC. SHALL
BE DEMOLISHED BACK TO THE FLOOR PANELS LOCATED IN THE
RESPECTIVE FLOORS ELECTRICAL CLOSETS.
PRIOR TO DOING ANY WORK IN THE BUILDING, THE CONTRACTOR
SHALL TEST AND DOCUMENT THE BUILDINGS FIRE ALARM
SYSTEM SEQUENCE OF OPERATION AND FUNCTIONALITY. HE
SHALL PAY STRICT ATTENTION TO FLOORS 3, 4, 6 AND 7. ALL
TESTING SHALL BE DONE IN THE PRESENCE OF THE GSA
ENGINEER/REPRESENTATIVE. ALL TESTING SHALL BE
CONDUCTED BY THE MANUFACTURER’S REPRESENTATIVE WITH
THE BUILDINGS MANAGER/FIRE SAFETY DIRECTOR. THE
CONTRACTOR SHALL SUBMIT TO GSA TESTING PROTOCOLS AND
A PROPOSED METHODS OF PROCEDURES (MOP) FOR REVIEW
AND APPROVALS. ONCE ACCEPTED, THE CONTRACTOR SHALL
TEST THE SYSTEM DURING NON-WORKING HOURS. TESTING
SHALL BE SCHEDULED AT LEAST 10 BUSINESS DAY IN ADVANCE.
ONCE TESTED, THE CONTRACTOR SHALL PRODUCE A RECORD
OF THE TEST FOR FUTURE REFERENCE. THIS DOCUMENT SHALL
BE SUBMITTED FOR RECORD AND USED DURING THE
COMMISSIONING OF THE NEW SYSTEM COMPONENTS/DEVICES.
ALL NEW DEVICES SHALL BE OF THE SAME MANUFACTURER AS
THE EXISTING BASE BUILDINGS FIRE ALARM SYSTEM. NEW
DEVICES SHALL BE PROVIDED AS SHOWN ON THE CONTRACT
DRAWINGS.
AFTER EACH FLOOR HAS BEEN COMPLETED, THE SYSTEM SHALL
BE RETESTED ON A FLOOR BY FLOOR BASIS. ALL WORK SHALL
BE COORDINATED WITH GSA. THE CONTRACTOR SHALL NOTE
THAT THE 7TH FLOOR IS BEING DONE IN 2 PHASES.
THE CONTRACTOR SHALL REPROGRAM THE OPERATION AND
FUNCTIONALITY OF ALL THE NEW DEVICES AS PER THE FIRE
ALARM MATRIX AND AS REQUIRED BY THE EXISTING BUILDING
FIRE ALARM SEQUENCE OF OPERATION. THIS INCLUDES
SHUTTING DOWN EXISTING MECHANICAL UNITS, REPROGRAMING
TAMPER AND FLOW SWITCHES, ETC.
0 - - N.T.S.
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:3
:2
P M
FA-00-01
FIRE ALARM LEGENDS & ABBREVIATIONS
04/23/2021
04/23/21NJA
RO
1 23
FIRE ALARM DRAWING LIST
DRAWING NO. DESCRIPTION
FA-00-01 FIRE ALARM LEGENDS & ABBREVIATIONS
FAD-13-00 FIRE ALARM DEMOLITION PLAN - LEVEL 3 - OVERALL
FAD-14-00 FIRE ALARM DEMOLITION PLAN - LEVEL 4 - OVERALL
FAD-16-00 FIRE ALARM DEMOLITION PLAN - LEVEL 6 - OVERALL
FAD-17-00 FIRE ALARM DEMOLITION PLAN - LEVEL 7 - OVERALL
FA-11-00 FIRE ALARM PLAN - LEVEL 1 - OVERALL
FA-13-00 FIRE ALARM PLAN - LEVEL 3 - OVERALL
FA-13-01 FIRE ALARM PLAN - LEVEL 3 - WEST
FA-13-02 FIRE ALARM PLAN - LEVEL 3 - EAST
FA-14-00 FIRE ALARM PLAN - LEVEL 4 - OVERALL
FA-14-01 FIRE ALARM PLAN - LEVEL 4 - WEST
FA-14-02 FIRE ALARM PLAN - LEVEL 4 - EAST
FA-16-00 FIRE ALARM PLAN - LEVEL 6 - OVERALL
FA-16-01 FIRE ALARM PLAN - LEVEL 6 - WEST
FA-16-02 FIRE ALARM PLAN - LEVEL 6 - EAST
FA-17-00 FIRE ALARM PLAN - LEVEL 7 - OVERALL
FA-17-01 FIRE ALARM PLAN - LEVEL 7 - WEST
FA-17-02 FIRE ALARM PLAN - LEVEL 7 - EAST
FA-50-00 FIRE ALARM RISER - INITIAL CONDITIONS
FA-50-01 FIRE ALARM RISER - NEW
FA-60-00 FIRE ALARM MATRIX - EXISTING
FA-70-00 FIRE ALARM DETAILS
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
DEMOLISH ALL FIRE ALARM FIXTURES AND DEVICES AS WELL AS ASSOCIATED CONDUCTORS BACK TO SOURCE. FIRE ALARM PANELS IN ELECTRICAL CLOSETS SHALL BE EXISTING TO REMAIN. STAIRCASES ON THIS FLOOR ARE NOT IN SCOPE.
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:0
:5
P M
FAD-13-00
FIRE ALARM DEMOLITION PLAN - LEVEL 3 - OVERALL
04/23/2021
04/23/21NJA
RO
2 23
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
DEMOLISH ALL FIRE ALARM FIXTURES AND DEVICES AS WELL AS ASSOCIATED CONDUCTORS BACK TO SOURCE. FIRE ALARM PANELS IN ELECTRICAL CLOSETS SHALL BE EXISTING TO REMAIN. STAIRCASES ON THIS FLOOR ARE NOT IN SCOPE.
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:0
:0
P M
FAD-14-00
FIRE ALARM DEMOLITION PLAN - LEVEL 4 - OVERALL
04/23/2021
04/23/21NJA
3 23
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
DEMOLISH ALL FIRE ALARM FIXTURES AND DEVICES AS WELL AS ASSOCIATED CONDUCTORS BACK TO SOURCE. FIRE ALARM PANELS IN ELECTRICAL CLOSETS SHALL BE EXISTING TO REMAIN. STAIRCASES ON THIS FLOOR ARE NOT IN SCOPE.
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:0
:1
P M
FAD-16-00
FIRE ALARM DEMOLITION PLAN - LEVEL 6 - OVERALL
04/23/2021
04/23/21NJA
4 23
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
DEMOLISH ALL FIRE ALARM FIXTURES AND DEVICES AS WELL AS ASSOCIATED CONDUCTORS BACK TO SOURCE. FIRE ALARM PANELS IN ELECTRICAL CLOSETS SHALL BE EXISTING TO REMAIN. STAIRCASES ON THIS FLOOR ARE NOT IN SCOPE.
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:0
:1
P M
FAD-17-00
FIRE ALARM DEMOLITION PLAN - LEVEL 7 - OVERALL
04/23/2021
04/23/21NJA
5 23
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO
SHEET
FA-13-01
REFER TO
SHEET
FA-13-02
REFER TO
SHEET
FA-13-01
REFER TO
SHEET
FA-13-02
RESTROOM (W)
3AWMN
RESTROOM (W)
3CWMN
TELECOM
3BTL1
ELECTRICAL
3BEL2
TELECOM
3BTL4
ELECTRICAL
3BEL3
OFFICE
3B114
OFFICE
3B113
OFFICE
3B112
OFFICE
3B111
OFFICE
3B115
OFFICE
3B116
OFFICE
3B110
STORAGE
3BS03
Room
ELECTRICAL
3AEL2
FREIGHT ELEV. LOBBY
3BFLV
STAIR 1
3AST
STAIR 2
3BST1
STAIR 4
3CST
STAIR 3
3BST2
WEST PANTRY
3APN
COPY
3A203
EAST PANTRY
3BPN
COPY
3B102
OFFICE
3B214
OFFICE
3B213
OFFICE
3B212
OFFICE
3B211
OFFICE
3B215
OFFICE
3B216
OFFICE
3B210
OFFICE
3C111
OFFICE
3C112
OFFICE
3C110
OFFICE
3C114
OFFICE
3C113
OFFICE
3C115
OFFICE
3C211
OFFICE
3C212
OFFICE
3C210
OFFICE
3C214
OFFICE
3C213
OFFICE
3C215
CORRIDOR
3C180
OFFICE
3A111
OFFICE
3A112
OFFICE
3A110
OFFICE
3A114
OFFICE
3A113
OFFICE
3A115
OFFICE
3A211
OFFICE
3A212
OFFICE
3A210
OFFICE
3A214
OFFICE
3A213
OFFICE
3A215
CONFERENCE
3A156 CONFERENCE
3A150
HUDDLE ROOM
3A251
HUDDLE ROOM
3A151
FOCUS
3A153
FOCUS
3A152
FOCUS
3A253
FOCUS
3A252
FOCUS
3A255
FOCUS
3A155
FOCUS
3A154
FOCUS
3A254
CONFERENCE
3C156
CONFERENCE
3C150
HUDDLE ROOM
3C251
HUDDLE ROOM
3C151
FOCUS
3C153
FOCUS
3C152
FOCUS
3C253
FOCUS
3C252
FOCUS
3C255
FOCUS
3C155
FOCUS
3C154
FOCUS
3C254
CONFERENCE
3C256
CONFERENCE
3B150
CONFERENCE
3B151
CONFERENCE
3B152
CONFERENCE
3B153
CONFERENCE
3B155
CONFERENCE
3B154
CONFERENCE
3B251
CONFERENCE
3B252
CONFERENCE
3B253
CONFERENCE
3B255
CONFERENCE
3B254
CORRIDOR
3B101
CONFERENCE
3B250
WEST ELEVATOR LOBBY
3BLV1
ELECTRICAL
3BEL1
TELECOM
3BTL2
ELECTRICAL
3BEL4
TELECOM
3BTL3 FOCUS ROOM
3C257
RESTROOM (M)
3CMEN
JANITOR
3CJA
ELECTRICAL
3CEL2
Room
TELECOM
3CTL2
TELECOM
3CTL1
ELECTRICAL
3CEL1
RESTROOM (M)
3AMEN
JANITOR
3AJA1
VESTIBULE
3A2VES
Room
ELECTRICAL
3AEL1
TELECOM
3ATL1Room
Room
FUTURE CLOSET
3ATL2
EAST ELEVATOR LOBBY
3BLV2
CORRIDOR
3A201
CORRIDOR
3A101
CORRIDOR
3A180
MOTHER'S ROOM
3AMRM
VESTIBULE
3C2VES
CORRIDOR
3C201
CORRIDOR
3C101
CORRIDOR
3A103
CORRIDOR
3C102
CORRIDOR
3B100
OPEN OFFICE
3B245
CORRIDOR
3A202
OPEN OFFICE
3A245
CORRIDOR
3A102
OPEN OFFICE
3A145
OPEN OFFICE
3C145
OPEN OFFICE
3C245
CORRIDOR
3C200
OPEN OFFICE
3B145
CORRIDOR
3B200
VESTIBULE
3A1VES
VESTIBULE
3C1VES
Room
7C535
Room
7C536
Room
7C537
Room
7C538
Room
7C539
Room
7C541
Room
7C542
Room
7C543
Room
7C544
Room
7C545
Room
7C546
Room
7C547
Room
7C548
Room
7C549
Room
7C550
Room
7C551
Room
7C552
Room
7C553
Room
7C554
Room
7C555
AV CLOSET
3A104
CORRIDOR
3C100
OFFICE
3A192
OFFICE
3A191
OFFICE
3A190
OFFICE
3A292
OFFICE
3A291
OFFICE
3A290
OFFICE
3A294
OFFICE
3C193
OFFICE
3C192
OFFICE
3C191
OFFICE
3C190
OFFICE
3C194
OFFICE
3C293
OFFICE
3C292
OFFICE
3C291
OFFICE
3C290
OFFICE
3C294
OFFICE
3C295
CONFERENCE
3A160
ASSISTANT SECRETARY'S
SUITE
3C181
CONFERENCE
3C160
OFFICE
3C284
OFFICE
3C240
OFFICE
3C285
OFFICE
3C243
OFFICE
3B230
OFFICE
3B232
OFFICE
3B231
OFFICE
3B233
OFFICE
3C288
OFFICE
3C286
OFFICE
3C287
OFFICE
3C289
OFFICE
3A130
OFFICE
3A132
OFFICE
3A133
OFFICE
3A131
OFFICE
3A230
OFFICE
3A232
OFFICE
3A233
OFFICE
3A231
OFFICE
3A293
OFFICE
3C238
OFFICE
3C239
OFFICE
3C241
OFFICE
3C242
OFFICE
3B237
OFFICE
3B236
OFFICE
3B241
OFFICE
3B240
OFFICE
3B234
OFFICE
3B235
OFFICE
3B238
OFFICE
3B239
OFFICE
3C184
OFFICE
3C140
OFFICE
3C185
OFFICE
3C143
OFFICE
3C138
OFFICE
3C139
OFFICE
3C141
OFFICE
3C142
OFFICE
3C188
OFFICE
3C186
OFFICE
3C187
OFFICE
3C189
OFFICE
3B130
OFFICE
3B132
OFFICE
3B131
OFFICE
3B133
OFFICE
3B137
OFFICE
3B136
OFFICE
3B141
OFFICE
3B140
OFFICE
3B134
OFFICE
3B135
OFFICE
3B138
OFFICE
3B139
OFFICE
3A295
OFFICE
3A194
OFFICE
3A193
OFFICE
3C195
OFFICE
3C196
COLLABORATION
3C271
COLLABORATION
3B270
COLLABORATION
3B271
COLLABORATION
3B170
COLLABORATION
3B171
COLLABORATION
3C171
OFFICE
3C136
OFFICE
3C134
OFFICE
3C137
OFFICE
3C135
OFFICE
3C131
OFFICE
3C130
OFFICE
3C133
OFFICE
3C132 COLLABORATION
3C170
OFFICE
3C236
OFFICE
3C234
OFFICE
3C237
OFFICE
3C235
OFFICE
3C231
OFFICE
3C230
OFFICE
3C233
OFFICE
3C232
COLLABORATION
3C270
ASSISTANT SECRETARY'S
SUITE
3A181
FOCUS
3C161
FOCUS
3C261
CORRIDOR
3A200
CORRIDOR
3A100
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:5
A M
FA-13-00
FIRE ALARM PLAN - LEVEL 3 - OVERALL
04/23/2021
04/23/21NJA
RO
7 23
1/16" = 1'-0"
FIRE ALARM REFLECTED CEILING PLANS - LEVEL 3 - OVERALL
FATC
S
P
S
NAC
S
S
S
S
S S
S
S
S
P
FP
S
S
S
S
FP
FP
WT
MM MM
W
TMM
MM
S
S
S
S S S S S SS
FATC NAC
S
S S SS S S S S S
S
S
S
S
S
S
S
S
S
S
S S S
S S
S
S
3a
3a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
FED FROM 'A' CLOSET
E 30cd
30cd
75cd
30cd
30cd
ETR
75cd
ETR
ETR
ETR ETR
ETR
ETR
30cd
30cd
75cd
30cd
75cd75cd75cd75cd 75cd 75cd
A M
P
30cd
30cd
75cd
75cd75cd75cd75cd75cd75cd75cd75cd 75cd
FIRE ALARM ZONE WEST
FED FROM 'A' CLOSET
FIRE ALARM ZONE WEST
30cd 30cd
30cd
30cd
RL
75cd
R
RRL
RL
R
RL
R
RL
R
RL
R
RL
R
RL
R
RESTROOM (W)
3AWMN
TELECOM
3BTL1
TELECOM
3BTL4
OFFICE
3B113
OFFICE
3B112
OFFICE
3B111
OFFICE
3B110
STORAGE
3BS03
ELECTRICAL
3AEL2
STAIR 1
3AST
STAIR 2
3BST1
WEST PANTRY
3APN
COPY
3A203
OFFICE
3B213
OFFICE
3B212
OFFICE
3B211
OFFICE
3B210
OFFICE
3A111
OFFICE
3A112
OFFICE
3A110
OFFICE
3A114
OFFICE
3A113
OFFICE
3A115
OFFICE
3A211
OFFICE
3A212
OFFICE
3A210
OFFICE
3A214
OFFICE
3A213
OFFICE
3A215
CONFERENCE
3A156
CONFERENCE
3A150
HUDDLE ROOM
3A251
HUDDLE ROOM
3A151
FOCUS
3A153
FOCUS
3A152
FOCUS
3A253
FOCUS
3A252
FOCUS
3A255
FOCUS
3A155
FOCUS
3A154
FOCUS
3A254
CONFERENCE
3B150
CONFERENCE
3B151
CONFERENCE
3B152
CONFERENCE
3B153
CONFERENCE
3B251
CONFERENCE
3B252
CONFERENCE
3B253
CONFERENCE
3B250
WEST ELEVATOR LOBBY
3BLV1
ELECTRICAL
3BEL1
ELECTRICAL
3BEL4
RESTROOM (M)
3AMEN
JANITOR
3AJA1
VESTIBULE
3A2VES
Room
ELECTRICAL
3AEL1
TELECOM
3ATL1
Room
Room
FUTURE CLOSET
3ATL2
CORRIDOR
3A201
CORRIDOR
3A101
CORRIDOR
3A180
MOTHER'S ROOM
3AMRM
CORRIDOR
3A103
OPEN OFFICE
3B245
CORRIDOR
3A202
OPEN OFFICE
3A245
CORRIDOR
3A102
OPEN OFFICE
3A145
OPEN OFFICE
3B145
CORRIDOR
3B200
VESTIBULE
3A1VES
Room
7C536
Room
7C537
Room
7C538
Room
7C539
Room
7C541
Room
7C542
Room
7C543
Room
7C544
Room
7C545
AV CLOSET
3A104
OFFICE
3A192
OFFICE
3A191
OFFICE
3A190
OFFICE
3A292
OFFICE
3A291
OFFICE
3A290
OFFICE
3A294
CONFERENCE
3A160
OFFICE
3A130
OFFICE
3A132
OFFICE
3A133
OFFICE
3A131
OFFICE
3A230
OFFICE
3A232
OFFICE
3A233
OFFICE
3A231
OFFICE
3A293
OFFICE
3A295
OFFICE
3A194
OFFICE
3A193
ASSISTANT SECRETARY'S
SUITE
3A181
CORRIDOR
3A200
CORRIDOR
3A100
0 8' 16' 1/8"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:0
A M
FA-13-01
FIRE ALARM PLAN - LEVEL 3 - WEST
04/23/2021
04/23/21NJA
RO
8 23
1/8" = 1'-0"
FIRE ALARM REFLECTED CEILING PLAN - LEVEL 3 - WEST
F A
T C
S
N A
C
S
P
S
S
FP
S
S
P
S
S
S
S S S
S
S S
FP
FPW T
MMMM
W
T MM
MM
S
S
S
S
S S S S
F A
T C
N A
C
S
S
S
S
S
S S S
S
S S
S
S S S S
S
S
S
S
S
S S
S
S S
S S S
S S S
S
S
S S S S
S S S S S
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
20a
20a
E
30cd
30cd
ETR
30cd
E
ETR
ETR
ETRETR
ETR
ETR
30cd
75cd 75cd
30cd
30cd
AMP
30cd
30cd
30cd
75cd
75cd
FED FROM 'H' CLOSET
FIRE ALARM ZONE EAST
FED FROM 'H' CLOSET
FIRE ALARM ZONE EAST
30cd
30cd
30cd
30cd
RL
R
RLR
RL
R
RL
R
RL
R
R RL
RL
R
R
RL
RESTROOM (W)
3CWMN
ELECTRICAL
3BEL2
ELECTRICAL
3BEL3
OFFICE
3B114
OFFICE
3B113
OFFICE
3B115
OFFICE
3B116
Room
FREIGHT ELEV. LOBBY
3BFLV
STAIR 4
3CST
STAIR 3
3BST2
EAST PANTRY
3BPN
COPY
3B102
OFFICE
3B214
OFFICE
3B213
OFFICE
3B215
OFFICE
3B216
OFFICE
3C111
OFFICE
3C112
OFFICE
3C110
OFFICE
3C114
OFFICE
3C113
OFFICE
3C115
OFFICE
3C211
OFFICE
3C212
OFFICE
3C210
OFFICE
3C214
OFFICE
3C213
OFFICE
3C215
CORRIDOR
3C180
CONFERENCE
3C156
CONFERENCE
3C150
HUDDLE ROOM
3C251
HUDDLE ROOM
3C151
FOCUS
3C153
FOCUS
3C152
FOCUS
3C253
FOCUS
3C252
FOCUS
3C255
FOCUS
3C155
FOCUS
3C154
FOCUS
3C254
CONFERENCE
3C256
CONFERENCE
3B152
CONFERENCE
3B153 CONFERENCE
3B155
CONFERENCE
3B154
CONFERENCE
3B252
CONFERENCE
3B253
CONFERENCE
3B255
CONFERENCE
3B254
CORRIDOR
3B101
TELECOM
3BTL2
TELECOM
3BTL3
FOCUS ROOM
3C257
RESTROOM (M)
3CMEN
JANITOR
3CJA
ELECTRICAL
3CEL2
Room
TELECOM
3CTL2
TELECOM
3CTL1
ELECTRICAL
3CEL1
EAST ELEVATOR LOBBY
3BLV2
VESTIBULE
3C2VES
CORRIDOR
3C201
CORRIDOR
3C101
CORRIDOR
3C102
CORRIDOR
3B100
OPEN OFFICE
3B245
OPEN OFFICE
3C145
OPEN OFFICE
3C245
CORRIDOR
3C200
OPEN OFFICE
3B145
CORRIDOR
3B200
VESTIBULE
3C1VES
Room
7C535 Room
7C546
Room
7C547
Room
7C548
Room
7C549
Room
7C550
Room
7C551
Room
7C552
Room
7C553 Room
7C554
Room
7C555
CORRIDOR
3C100
OFFICE
3C193
OFFICE
3C192
OFFICE
3C191
OFFICE
3C190
OFFICE
3C194
OFFICE
3C293
OFFICE
3C292
OFFICE
3C291
OFFICE
3C290
OFFICE
3C294
OFFICE
3C295
ASSISTANT SECRETARY'S
SUITE
3C181
CONFERENCE
3C160
OFFICE
3C284
OFFICE
3C240
OFFICE
3C285
OFFICE
3C243
OFFICE
3B230
OFFICE
3B232
OFFICE
3B231
OFFICE
3B233
OFFICE
3C288
OFFICE
3C286
OFFICE
3C287
OFFICE
3C289
OFFICE
3C238
OFFICE
3C239
OFFICE
3C241
OFFICE
3C242
OFFICE
3B237
OFFICE
3B236
OFFICE
3B241
OFFICE
3B240
OFFICE
3B234
OFFICE
3B235
OFFICE
3B238
OFFICE
3B239
OFFICE
3C184
OFFICE
3C140
OFFICE
3C185
OFFICE
3C143
OFFICE
3C138
OFFICE
3C139
OFFICE
3C141
OFFICE
3C142
OFFICE
3C188
OFFICE
3C186
OFFICE
3C187
OFFICE
3C189
OFFICE
3B130
OFFICE
3B132
OFFICE
3B131
OFFICE
3B133
OFFICE
3B137
OFFICE
3B136
OFFICE
3B141
OFFICE
3B140
OFFICE
3B134
OFFICE
3B135
OFFICE
3B138
OFFICE
3B139
OFFICE
3C195
OFFICE
3C196
COLLABORATION
3C271
COLLABORATION
3B270
COLLABORATION
3B271
COLLABORATION
3B170
COLLABORATION
3B171
COLLABORATION
3C171
OFFICE
3C136
OFFICE
3C134
OFFICE
3C137
OFFICE
3C135
OFFICE
3C131
OFFICE
3C130
OFFICE
3C133
OFFICE
3C132
COLLABORATION
3C170
OFFICE
3C236
OFFICE
3C234
OFFICE
3C237
OFFICE
3C235
OFFICE
3C231
OFFICE
3C230
OFFICE
3C233
OFFICE
3C232
COLLABORATION
3C270
FOCUS
3C161
FOCUS
3C261
0 8' 16' 1/8"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:1
A M
FA-13-02
FIRE ALARM PLAN - LEVEL 3 - EAST
04/23/2021
04/23/21NJA
RO
9 23
1/8" = 1'-0"
FIRE ALARM REFLECTED CEILING PLAN - LEVEL 3 - EAST
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO
SHEET
FA-14-01
REFER TO
SHEET
FA-14-02
REFER TO
SHEET
FA-14-01
REFER TO
SHEET
FA-14-02
RESTROOM (W)
4AWMN
RESTROOM (W)
4CWMN
TELECOM
4BTL1
ELECTRICAL
4BEL2
TELECOM
4BTL4
ELECTRICAL
4BEL3
OFFICE
4B114
OFFICE
4B113
OFFICE
4B112
OFFICE
4B111
OFFICE
4B115
OFFICE
4B116
OFFICE
4B110
STAIR 4
4CST
Room
STORAGE
4BS03
Room
Room
ELECTRICAL
4AEL2
FREIGHT ELEV. LOBBY
4BFLV
STAIR 1
4AST
STAIR 2
4BST1
STAIR 3
4BST2
Room
WEST PANTRY
4APN
COPY
4A203
EAST PANTRY
4BPN
COPY
4B102
OFFICE
4B214
OFFICE
4B213
OFFICE
4B212
OFFICE
4B211
OFFICE
4B215
OFFICE
4B216
OFFICE
4B210
OFFICE
4C111
OFFICE
4C112
OFFICE
4C110
OFFICE
4C114
OFFICE
4C113
OFFICE
4C115
OFFICE
4C211
OFFICE
4C212
OFFICE
4C210
OFFICE
4C214
OFFICE
4C213
OFFICE
4C215
OFFICE
4A111
OFFICE
4A112
OFFICE
4A110
OFFICE
4A114
OFFICE
4A113
OFFICE
4A115
OFFICE
4A211
OFFICE
4A212
OFFICE
4A210
OFFICE
4A214
OFFICE
4A213
OFFICE
4A215
CONFERENCE
4A156
CONFERENCE
4A150
HUDDLE ROOM
4A251
HUDDLE ROOM
4A151
FOCUS
4A153
FOCUS
4A152
FOCUS
4A253
FOCUS
4A252
FOCUS
4A255
FOCUS
4A155
FOCUS
4A154
FOCUS
4A254
CONFERENCE
4C156
CONFERENCE
4C150
HUDDLE ROOM
4C251
HUDDLE ROOM
4C151
FOCUS
4C153
FOCUS
4C152
FOCUS
4C253
FOCUS
4C252
FOCUS
4C255
FOCUS
4C155
FOCUS
4C154
FOCUS
4C254
CONFERENCE
4C256
CONFERENCE
4B150
CONFERENCE
4B151
CONFERENCE
4B152
CONFERENCE
4B153
CONFERENCE
4B155
CONFERENCE
4B154
CONFERENCE
4B251
CONFERENCE
4B252
CONFERENCE
4B253
CONFERENCE
4B255
CONFERENCE
4B254
CORRIDOR
4B101
CONFERENCE
4B250
ELECTRICAL
4BEL1
TELECOM
4BTL2
ELECTRICAL
4BEL4
TELECOM
4BTL3
Room
4BS01
Room
Room
4BS02
Room
Room
Room
Room
Room
FOCUS ROOM
4C257
RESTROOM (M)
4CMEN
JANITOR
4CJA
ELECTRICAL
4CEL2
Room
TELECOM
4CTL2
Room
TELECOM
4CTL1
ELECTRICAL
4CEL1
RESTROOM (M)
4AMEN
JANITOR
4AJA1
MOTHER'S ROOM
4AMRM
Room
ELECTRICAL
4AEL1
TELECOM
4ATL1Room
Room
Room
FUTURE CLOSET
4ATL2
OFFICE
4A133
OFFICE
4A132
OFFICE
4A131
OFFICE
4A130
OFFICE
4B133
OFFICE
4B132
OFFICE
4B131
OFFICE
4B130
OFFICE
4B233
OFFICE
4B232
OFFICE
4B231
OFFICE
4B230
OFFICE
4A233
OFFICE
4A232
OFFICE
4A231
OFFICE
4A230
OFFICE
4C192
OFFICE
4C191
OFFICE
4C190
OFFICE
4C292
OFFICE
4C291
OFFICE
4C290
OFFICE
4A192
OFFICE
4A191
OFFICE
4A190
OFFICE
4A292
OFFICE
4A291
OFFICE
4A290
OFFICE
4A293
OFFICE
4A294
WEST ELEVATOR LOBBY
4BLV1
EAST ELEVATOR LOBBY
4BLV2
CORRIDOR
4B200
COLLABORATION
4A170
COLLABORATION
4B170
COLLABORATION
4A270
COLLABORATION
4B270
OFFICE
4A237
OFFICE
4A236
OFFICE
4A235
OFFICE
4A234
COLLABORATION
4A271
OFFICE
4A137
OFFICE
4A136
OFFICE
4A135
OFFICE
4A134
COLLABORATION
4A171
ASSISTANT SECRETARY'S
SUITE
4A181
CONFERENCE
4A160
ASSISTANT SECRETARY'S
SUITE
4C181
CONFERENCE
4C160
CORRIDOR
4A101
CORRIDOR
4C101
CORRIDOR
4C201
CORRIDOR
4C180
OPEN OFFICE
4A245
OPEN OFFICE
4B245
OPEN OFFICE
4C245
OPEN OFFICE
4A246
OPEN OFFICE
4B145
OPEN OFFICE
4C145
OPEN OFFICE
4A145OPEN OFFICE
4A146
CORRIDOR
4C100
CORRIDOR
4C200
CORRIDOR
4C102
CORRIDOR
4A102
CORRIDOR
4A103
CORRIDOR
4A202
VESTIBULE
4C2VES
VESTIBULE
4A2VES
CORRIDOR
4B100
CORRIDOR
4A200
OFFICE
4A295
OFFICE
4A194
OFFICE
4A193
CORRIDOR
4A180
CORRIDOR
4A201
AV CLOSET
4A104
FOCUS
4C261
FOCUS
4C262
OFFICE
4C294
OFFICE
4C194
OFFICE
4C293
OFFICE
4C193
VESTIBULE
4C1VES
VESTIBULE
4A1VES
CORRIDOR
4A100
0 16' 32' 1/16"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:5
A M
FA-14-00
FIRE ALARM PLAN - LEVEL 4 - OVERALL
04/23/2021
04/23/21NJA
RO
10 23
1/16" = 1'-0"
FIRE ALARM REFLECTED CEILING PLANS - LEVEL 4 - OVERALL
FATC NAC
P
S
S
S
S
S
S
S
P
FP
S
S
S
FP
FP
WT
MM MM
W
TMM
MM
S S SS S S S SS
S S
S
S
S
S
S
S S S
S
S S S S SS
S S
FATC NAC
S
S
S
S
S
S
S
S
S
S S S
S S S
SS
3a
3a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
E 30cd
30cd
30cd
30cd
ETR
ETR
ETR
ETR ETR
ETR
ETR
FED FROM 'A' CLOSET
FIRE ALARM ZONE WEST
FED FROM 'A' CLOSET
FIRE ALARM ZONE WEST
30cd
30cd
30cd
30cd
30cd
75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd
A M
P
30cd
RESTROOM (W)
4AWMN
TELECOM
4BTL1
TELECOM
4BTL4
OFFICE
4B113
OFFICE
4B112
OFFICE
4B111
OFFICE
4B110Room
STORAGE
4BS03
ELECTRICAL
4AEL2
STAIR 1
4AST
STAIR 2
4BST1
WEST PANTRY
4APN
COPY
4A203
OFFICE
4B213
OFFICE
4B212
OFFICE
4B211
OFFICE
4B210
OFFICE
4A111
OFFICE
4A112
OFFICE
4A110
OFFICE
4A114
OFFICE
4A113
OFFICE
4A115
OFFICE
4A211
OFFICE
4A212
OFFICE
4A210
OFFICE
4A214
OFFICE
4A213
OFFICE
4A215
CONFERENCE
4A156
CONFERENCE
4A150
HUDDLE ROOM
4A251
HUDDLE ROOM
4A151
FOCUS
4A153
FOCUS
4A152
FOCUS
4A253
FOCUS
4A252
FOCUS
4A255
FOCUS
4A155
FOCUS
4A154
FOCUS
4A254
CONFERENCE
4B150
CONFERENCE
4B151
CONFERENCE
4B152
CONFERENCE
4B153
CONFERENCE
4B251
CONFERENCE
4B252
CONFERENCE
4B253
CONFERENCE
4B250
ELECTRICAL
4BEL1
ELECTRICAL
4BEL4
Room
4BS01
Room
Room
4BS02
RESTROOM (M)
4AMEN
JANITOR
4AJA1
MOTHER'S ROOM
4AMRM
Room
ELECTRICAL
4AEL1
TELECOM
4ATL1
Room
Room
Room
FUTURE CLOSET
4ATL2
OFFICE
4A133
OFFICE
4A132
OFFICE
4A131
OFFICE
4A130
OFFICE
4A233
OFFICE
4A232
OFFICE
4A231
OFFICE
4A230
OFFICE
4A192
OFFICE
4A191
OFFICE
4A190
OFFICE
4A292
OFFICE
4A291
OFFICE
4A290
OFFICE
4A293
OFFICE
4A294
WEST ELEVATOR LOBBY
4BLV1
CORRIDOR
4B200
COLLABORATION
4A170
COLLABORATION
4A270
OFFICE
4A237
OFFICE
4A236
OFFICE
4A235
OFFICE
4A234
COLLABORATION
4A271
OFFICE
4A137
OFFICE
4A136
OFFICE
4A135
OFFICE
4A134
COLLABORATION
4A171
ASSISTANT SECRETARY'S
SUITE
4A181
CONFERENCE
4A160
CORRIDOR
4A101
OPEN OFFICE
4A245
OPEN OFFICE
4B245
OPEN OFFICE
4A246
OPEN OFFICE
4B145
OPEN OFFICE
4A145
OPEN OFFICE
4A146
CORRIDOR
4A102
CORRIDOR
4A103
CORRIDOR
4A202
VESTIBULE
4A2VES
CORRIDOR
4B100
CORRIDOR
4A200
OFFICE
4A295
OFFICE
4A194
OFFICE
4A193
CORRIDOR
4A180
CORRIDOR
4A201
AV CLOSET
4A104
VESTIBULE
4A1VES
CORRIDOR
4A100
75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd
30cd
30cd
30cd
RL
R
RL
R
RL
R
RL
R
RL
R
RRL
RL
R
RL
R
0 8' 16' 1/8"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:0
A M
FA-14-01
FIRE ALARM PLAN - LEVEL 4 - WEST
04/23/2021
04/23/21NJA
RO
11 23
1/8" = 1'-0"
FIRE ALARM REFLECTED CEILING PLAN - LEVEL 4 - WEST
F A
T C
N A
C
S
S
P S
S
FP
S
S
P
S
S
S
FP
FPW T
MMMM
W
T MM
MM
S
S
S
S S S
S
S S S S SSS
S
S
S
S
S
S S S
S
S S S S SSS
F A
T C
N A
C
S
S
S
S
S
S
S S S
S S S
S S
S
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
20a
20a
E
30cd
30cd
ETR
30cd
E
ETR
ETR
ETRETR
ETR
ETR
30cd
FED FROM 'H' CLOSET
FIRE ALARM ZONE EAST
FED FROM 'H' CLOSET
FIRE ALARM ZONE EAST
75cd 75cd 75cd 75cd 75cd 75cd 75cd
30cd
30cd
30cd
30cd
30cd
75cd 75cd 75cd
AMP
RESTROOM (W)
4CWMN
ELECTRICAL
4BEL2
ELECTRICAL
4BEL3
OFFICE
4B114
OFFICE
4B113
OFFICE
4B115
OFFICE
4B116
STAIR 4
4CST
Room
Room
FREIGHT ELEV. LOBBY
4BFLV
STAIR 3
4BST2
Room
EAST PANTRY
4BPN
COPY
4B102
OFFICE
4B214
OFFICE
4B213
OFFICE
4B215
OFFICE
4B216
OFFICE
4C111
OFFICE
4C112
OFFICE
4C110
OFFICE
4C114
OFFICE
4C113
OFFICE
4C115
OFFICE
4C211
OFFICE
4C212
OFFICE
4C210
OFFICE
4C214
OFFICE
4C213
OFFICE
4C215
CONFERENCE
4C156
CONFERENCE
4C150
HUDDLE ROOM
4C251
HUDDLE ROOM
4C151
FOCUS
4C153
FOCUS
4C152
FOCUS
4C253
FOCUS
4C252
FOCUS
4C255
FOCUS
4C155
FOCUS
4C154
FOCUS
4C254
CONFERENCE
4C256
CONFERENCE
4B152
CONFERENCE
4B153 CONFERENCE
4B155
CONFERENCE
4B154
CONFERENCE
4B252
CONFERENCE
4B253
CONFERENCE
4B255
CONFERENCE
4B254
CORRIDOR
4B101
TELECOM
4BTL2
TELECOM
4BTL3
Room
Room
Room
Room
Room
FOCUS ROOM
4C257
RESTROOM (M)
4CMEN
JANITOR
4CJA
ELECTRICAL
4CEL2
Room
TELECOM
4CTL2
Room
TELECOM
4CTL1
ELECTRICAL
4CEL1
OFFICE
4B133
OFFICE
4B132
OFFICE
4B131
OFFICE
4B130
OFFICE
4B233
OFFICE
4B232
OFFICE
4B231
OFFICE
4B230
OFFICE
4C192
OFFICE
4C191
OFFICE
4C190
OFFICE
4C292
OFFICE
4C291
OFFICE
4C290
EAST ELEVATOR LOBBY
4BLV2
COLLABORATION
4B170
COLLABORATION
4B270
ASSISTANT SECRETARY'S
SUITE
4C181
CONFERENCE
4C160
CORRIDOR
4C101
CORRIDOR
4C201
CORRIDOR
4C180
OPEN OFFICE
4B245 OPEN OFFICE
4C245
OPEN OFFICE
4B145
OPEN OFFICE
4C145
CORRIDOR
4C100
CORRIDOR
4C200
CORRIDOR
4C102
VESTIBULE
4C2VES
CORRIDOR
4B100
FOCUS
4C261
FOCUS
4C262
OFFICE
4C294
OFFICE
4C194
OFFICE
4C293
OFFICE
4C193
VESTIBULE
4C1VES
75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd 75cd
30cd
30cd
30cd
30cd
RL
R
R RL
RL
R
R
RL
RL
R
RL
R
RL
R
RL
R
0 8' 16' 1/8"=1'-0"
SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.
Do not remove this notice. Properly destroy or return documents when no longer needed.
TRUE NORTH
PLAN NORTH
CHECKED BY
DRAWN BY
FLOOR NUMBER
DRAWING TITLE
SHEET
NUMBER
SUBMISSION DATE
SUBMISSION STAGE
GSA PM
GSA PROJECT NO.
PROJECT
DESCRIPTION
PROJECT TITLE
BUILDING NAME
ADDRESS
BUILDING NUMBER
PRIME CONTR. NO.
PRIME ORDER NO.
CONST. CONTR.
A/E
SUB A/E
CONST. CONTR. NO.
SHEET SIZE:
DATE DRAWN:
36 X 48
S H
E E
T
ID
E N
TI
FI
C A
TI
O
N
DISCIPLINE
P R
O
JE
C T
ID
E
N
TI
FI
C
A
TI
O N
B U
IL
D
IN
G
BIM FILE NAME
C O
N
TR
A C
TO
R
S R
E V
IS
IO
N B
LO
C
K G
R A
P H
IC
S
C A
LE
K
E Y
P
LA
N S
TA
M
P O
R S
E A
L D
E S
IG
N
E R
ID
E
N
TI
FI
C
A
TI
O N
O W
N E
R
ID
E N
TI
FI
C A
TI
O
N
SHEET OF SHEETS
KRUECK & SEXTON ARCHITECTS, P.C.
400 MARYLAND AVENUE, SW
WASHINGTON, DC 20024
LYNDON B. JOHNSON FEDERAL BUILDING
DC0010ZZ
DC0010_E_3-4-6-7_r2020.rvt
WSP ENGINEERING
DEPARTMENT OF EDUCATION
CONSOLIDATION PROJECT
ISSUED FOR BID
HALLIE FUTTERMAN
RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING
BUILDING TO MEET THE DEPARTMENT OF
EDUCATION’S PROGRAMMATIC REQUIREMENTS.
GS-07-P-16-UC-D-7000
47PM0520F0002
47PM0520F0002
KRUECK & SEXTON ARCHITECTS
221 W ERIE ST
CHICAGO, IL 60654 (312) 787-0056
ARCHITECT
WSP ENGINEERING
ONE PENNSYLVANIA PLAZA, SECOND FLOOR
NEW YORK, NY 10119 (212) 465-5000
MEP ENGINEER
ATELIER TEN
45 E 20TH ST, 4TH FLOOR
NEW YORK, NY 10003 (312) 386-1400
SUSTAINABILITY CONSULTANT
THRESHOLD ACOUSTICS
141 W JACKSON BLVD, SUITE 2080
CHICAGO, IL 60604 (312) 386-1400
ACOUSTIC CONSULTANT
WEST EAST
M A
TC
H
LI
N
E
GENERAL NOTESLEGEND KEY NOTES
GENERAL SERVICES ADMINISTRATION
NATIONAL CAPITAL REGION
PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.
7TH & D STREET, S.W.
WASHINGTON, D.C. 20407
ISSUE
NO. DATE ISSUE
FIRE ALARM
VARIES, SEE DRAWINGS
01 04/23/2021 ISSUED FOR BID
FORCADE DESIGN
1626 PAYNE STREET
EVANSTON, IL 60201 (847) 448-4270
ENVIRONMENTAL GRAPHICS CONSULTANT
/2
/2
:5
:0
A M
FA-14-02
FIRE ALARM PLAN - LEVEL 4 - EAST
04/23/2021
04/23/21NJA
RO
12 23
1/8" = 1'-0"
FIRE ALARM REFLECTED CEILING PLAN - LEVEL 4 - EAST
3a
3a
20a
20a
F F
E E
D D
C C
B B
A A
A A
B B
C C
D D
E E
F F
3a
3a
20a
20a
REFER TO
SHEET
FA-16-01
REFER TO
SHEET
FA-16-02
REFER TO
SHEET
FA-16-01
REFER TO
SHEET
FA-16-02
RESTROOM (W)
6AWMN
RESTROOM (W)
6CWMN
TELECOM
6BTL1
ELECTRICAL
6BEL2
TELECOM
6BTL4
ELECTRICAL
6BEL3
OFFICE
6B114
OFFICE
6B113
OFFICE
6B112
OFFICE
6B111
OFFICE
6B115
OFFICE
6B116
OFFICE
6B110
STAIR 4
6CST
STORAGE
6BS03
Room
ELECTRICAL
6AEL2
FREIGHT ELEV. LOBBY
6BFLV
STAIR 1
6AST
STAIR 2
6BST1
STAIR 3
6BST2
Room
WEST PANTRY
6APN
COPY
6A203
EAST PANTRY
6BPN
COPY
6B102
OFFICE
6B214
OFFICE
6B213
OFFICE
6B212
OFFICE
6B211
OFFICE
6B215
OFFICE
6B216
OFFICE
6B210
OFFICE
6C111
OFFICE
6C112
OFFICE
6C110
OFFICE
6C114
OFFICE
6C113
OFFICE
6C115
OFFICE
6C211
OFFICE
6C212
OFFICE
6C210
OFFICE
6C214
OFFICE
6C213
OFFICE
6C215
CORRIDOR
6C180
OFFICE
6A111
OFFICE
6A112
OFFICE
6A110
OFFICE
6A114
OFFICE
6A113
OFFICE
6A115
OFFICE
6A211
OFFICE
6A212
OFFICE
6A210
OFFICE
6A214
OFFICE
6A213
OFFICE
6A215
CORRIDOR
6A180
CONFERENCE
6A156 CONFERENCE
6A150
HUDDLE ROOM
6A…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .