1914_GSA-DoED_Issue for Bid - Architectural_210423_Vol 3.pdf

PDF 47 MB Posted

Attached to
Solicitation Notice - LBJ Consolidation & Switchgear Federal contract opportunity
Solicitation number
47PM0121R0013
Issued by
General Services Administration Public Buildings Service

About this file

This solicitation notice is for repair, alteration, and construction services for the LBJ Consolidation Construction & Switchgear project. The General Services Administration seeks a firm fixed-price contract to renovate approximately 198,369 square feet of office space and 10,000 square feet of bathrooms in an existing building to reconstruct as open office space and meet increased workspace requirements for the Department of Education. Scope of work includes interior alterations, open workspace construction, HVAC and electrical upgrades including significant renovations to switchgear systems servicing the building. The NAICS code is 236220 and small business size standard is $39.5 million in average annual receipts. The solicitation closing date is June 4, 2021. A virtual pre-proposal conference will be held on May 5, 2021 and interested firms must register to receive the meeting invitation. All information and amendments will be posted on SAM.gov and firms must register in SAM to submit proposals.

View the file

Other files for this federal contract opportunity

Other files attached to Solicitation Notice - LBJ Consolidation & Switchgear, newest first.
File Type Posted
SF30 47PM0121R0013_0004.pdf PDF
SF30 47PM0121R0013_0003.pdf PDF
AS-50-06 - Sign Types Detail Sheet.pdf PDF
Solicitation 47PM0121R0013 revised 20210604.pdf PDF
AS-50-03 - Sign Types Detail Sheet.pdf PDF
SF30 47PM0121R0013_0002.pdf PDF
RFI and Response_5.24.21.pdf PDF
WageDet DC20210002 20210507.pdf PDF
GSA-DoED_Addendum-02_5.24.21.pdf PDF
014000 Quality Assurance and Control_5.24.21 Revision.pdf PDF
GSA-DoED_Addendum-02_MEP_5.24.21.pdf PDF
Bid Spreadsheet_Rev 1_5.24.21.xlsx XLSX spreadsheet
012400 Options_5.24.21 Revision.pdf PDF
26 32 13 - ENGINE GENERATOR(S) AND ACCESSORIES.pdf PDF
1914_GSA-DoED_Issue for Bid - Architectural_210423_Vol 2.pdf PDF
LBJ 1959 Full Set Vol 1.pdf PDF
SF30 47PM0121R0013_0001.pdf PDF
PreProposal Minutes Attendee List.pdf PDF
1914_GSA-DoED_Issue for Bid - Architectural_210423_Vol 1 SMALL.pdf PDF
GSA LBJ DoED IFB SPEC Vol 1rev.pdf PDF
LBJ 1959 Full Set Vol 2.pdf PDF
GSA527.pdf PDF
Drawing - HVAC.pdf PDF
Drawing - FA.pdf PDF
Drawing - ELEC.pdf PDF
Drawing - AV.pdf PDF
1914_GSA-DoED_L2 L5 - Combined_210423.pdf PDF
Contractor Site Office.pdf PDF
Narrative Modernization Issue for Bid LBJ 2021April23.pdf PDF
SOW LBJ Consolidation Construction Services.pdf PDF
Instructions LBJ Virtual Site Walk READ ME.pdf PDF
Drawings - ARCH Vol 1.pdf PDF
Drawing - Signage.pdf PDF
Drawing - TELE.pdf PDF
1914_GSA-DoED_Switchgear - Electrical_210423.pdf PDF
Layout for staging - switchgear.pdf PDF
2019.07.12_LBJ_BPP 100% Submission.pdf PDF
SF1442 47PM0121R0013.pdf PDF
Agreement (draft) RFP 47PM0121R0013.pdf PDF
Bid Spreadsheet.xlsx XLSX spreadsheet
Drawings - ARCH Vol 2.pdf PDF
Drawing - FP.pdf PDF
LBJ_5thFl_bathrooms-Staging.pdf PDF
SFLLL.pdf PDF
Solicitation 47PM0121R0013.pdf PDF
Reps and Certs 47PM0121R0013.pdf PDF
Drawing - PLUM.pdf PDF
SPEC Vol 1 GSA LBJ DoED.pdf PDF
SPEC Vol 2 GSA LBJ DoED.pdf PDF
LBJ_2ndFl_bathrooms-Staging.pdf PDF
Show all 50

Solicitation Notice - LBJ Consolidation & Switchgear has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

GL-06

MTL-01

MTL-01

GL-06

MTL-01

WALL BASE

WINDOW SHADE

GL-02 GL-02

WALL BASE

WALLCOVERING

Executive Suite

1'-8"

/8

SIGNAGE

Executive Suite

MTL-02

GL-04

MTL-02

MTL-02

GL-04

MTL-02

WALL BASE 3 EQ PANELS

MTL-02

GL-04

MTL-02

WALLCOVERING

WINDOW SHADE

WALL BASE

GL-06

MTL-01

MTL-01MTL-01

GL-06

Office of the Secretary Executive Suite1

3'-6 5/32"

/3

SIGNAGE

PTD. GWB

GL-02

MTL-02

MTL-02 MTL-02

GL-04GL-04

MTL-02

3 EQ PANELS

MTL-02 MTL-02

GL-04

WALL BASE

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WALLCOVERING

FWP

1 1/2"6 EQ. PANELS1 1/2"

1 1/2"1 1/2"

ST-02

WALLCOVERING

CONCEALED SUPPORTS TO IN WALL

STRUCTURE. "DELEGATED DESIGN"

MTL-01

A L

IG

N

A L

IG

N

WALL BASE

EQ. EQ.EQ. EQ. FWP

15'-3 1/4" V.I.F.

A-50-01

B P

A N

E L

/4

FWP

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WALLCOVERING

WALLCOVERING BEYONDWALLCOVERING BEYOND

EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

WINDOW SHADE

G3G3

WALL BASE WALL BASE

GL-02

PTD. GWB

WV

WALL BASEWALL BASE

GL-02

WV

WV WV

G1

WALL BASE

WV

WALL BASE

WV

WALL BASE

GL-06

MTL-01

MTL-01

MTL-01

GL-06

MTL-01MTL-01

GL-06

MTL-01

GL-06

WALL BASERECESSED INTO FIRE RATED WALL RECESSED INTO FIRE RATED WALL

WALLCOVERING

FEC FEC

WV

WALL BASE WALL BASEWALL BASE

WALLCOVERING

GL-02

G9 G3 G3 G9

WALL BASE

GL-02 PTD. GWB PTD. GWB PTD. GWB

WALL BASE

PTD. GWB

WALL BASE

WV WV

WALL BASE WALL BASE

WV

WALL BASEWALL BASE

GL-02

GL-06

MTL-01MTL-02

MTL-01

GL-06

MTL-02

G5 G3

GL-06

MTL-02

WALL BASE

GL-06

MTL-01

GL-02 GL-02

WALL BASE

PTD. GWB

WV

WALL BASE WALL BASE

GL-02

PENDANT LIGHT FIXTUREPENDANT LIGHT FIXTURE

WALL BASE

PTD. GWB

PENDANT LIGHT FIXTURE

WALL BASE

PTD. GWB

WALL BASE

PENDANT LIGHT FIXTUREPENDANT LIGHT FIXTURE

MONITOR, SEE PLAN, ELECTRICAL,

AND AV DRAWINGS.

PTD. GWBPENDANT LIGHT FIXTURE

WALL BASE

PTD. GWB

EQ-10

A-50-01

A-50-01

A-50-01

A-50-01

3/4" RVL.

7 EQ. PANELS3/4" RVL.

EQ-15

3/4" RVL.

2'-2"

3/4" RVL.

A L

IG

N

PULPUL

PUL

WV-01

WV-01

ST-02ST-02

FULL HEIGHT

BACKSPLASH

MTL-01

T Y

P

/4

R

V L

CUTOUT ON

FULL HEIGHT

BACKSPLAS

H FOR

POWER

OUTLET

A-50-01

2'-9 1/2"

PTD-1

TYP.TYP.

PTD. GWB

P1

A-50-01

A-50-01

A-50-01

A-50-01

PTD. GWBPTD. GWBPTD. GWB

EQ-2

EQ-10

A-50-01

A-50-01

PTD. GWB

WALL BASE

EQ-2

WV-1

ST-02ST-02

MTL-01

TYP.

3/4" RVL.

V.I.F.

2'-4 3/4"

TYP.

3/4" RVL.

WV-1

TYP.

3/4" RVL.

T Y

P

/4

R

V L

A-50-01

A-50-01

PTD. GWB

WALL BASE

"3/4" TYP.

A-50-01

A-50-01

@ SIDES &

TOP/ CABINET

@ SIDES &

TOP/ CABINET

PL-02

PL-02

ST-02

3/4" TYP.

PTD. GWB

P1

FULL HEIGHT

BACKSPLASH

EXISTING HISTORIC MARBLE

VINYL FILM

0 4' 8' 1/4"=1'-0"

KEY NOTES

GENERAL NOTES

LEGEND

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:3

P

M

A-20-10

ELEVATIONS - SECRETARY SUITE

RT + VW + SK

AC + SP

1/4" = 1'-0"1

SEC SUITE RECEPTION - WEST

1/4" = 1'-0"2

SEC SUITE RECEPTION - SOUTH

1/4" = 1'-0"3

SEC SUITE RECEPTION - EAST

1/4" = 1'-0"8

SEC SUITE CONFERENCE - NORTH

S E

N S

IT

IV

E B

U T

U N

C L

A S

S

IF

IE

D

S

B U

P

R O

P E

R T

Y O

F T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

N M

E N

T F

O R

O F

F

IC

E U

S E

O N

L Y

D o n o t re m o ve t h is n o ti ce

P ro p er ly d es tr o y o r re tu rn d o cu m en ts w h en n o lo n g er n ee d ed

1/4" = 1'-0"5

SEC SUITE CONFERENCE - WEST

1/4" = 1'-0"6

SEC SUITE CONFERENCE - SOUTH

1/4" = 1'-0"7

SEC SUITE CONFERENCE - EAST

1/4" = 1'-0"4

SEC SUITE RECEPTION - NORTH

1/4" = 1'-0"10

SEC SUITE CORRIDOR (NORTH) - NORTH

1/4" = 1'-0"11

SEC SUITE CORRIDOR (NORTH) - SOUTH

1/4" = 1'-0"9

SEC SUITE CORRIDOR (SERVICE) - EAST

1/4" = 1'-0"12

SEC SUITE CORRIDOR (SERVICE) - WEST

1/4" = 1'-0"25

SEC SUITE CORRIDOR (SOUTH) - NORTH

1/4" = 1'-0"26

SEC SUITE CORRIDOR (SOUTH) - SOUTH

1/4" = 1'-0"15

SEC SUITE CORRIDOR (MAIN) - WEST

1/4" = 1'-0"14

SEC SUITE CORRIDOR (MAIN) - SOUTH

1/4" = 1'-0"20

SEC SUITE CORRIDOR (MAIN) - EAST

1/4" = 1'-0"13

SEC SUITE CORRIDOR (MAIN) - NORTH

1/4" = 1'-0"16

ELEV - SAFE ROOM

1/4" = 1'-0"17

ELEV - SAFE ROOM

1/4" = 1'-0"18

ELEV - SAFE ROOM

1/4" = 1'-0"19

ELEV - SAFE ROOM

1/4" = 1'-0"22

ELEV - SUPPORT

1/4" = 1'-0"21

ELEV - SUPPORT

1/4" = 1'-0"23

ELEV - SUPPORT

1/4" = 1'-0"24

ELEV - SUPPORT

1/4" = 1'-0"27

ELEV - LOWER AND UPPER

G1 G1 / A-20-06

G3 G3 / A-20-06

G5 G5 / A-20-06

G9 G9 / A-20-06

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYONDOPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

OPEN

TO

BEYOND

G5

WALL BASE

PENDANT LIGHT FIXTURE

WINDOW SHADE

PTD. GWB

WINDOW SHADE EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WALL BASE

PENDANT LIGHT FIXTURE WINDOW SHADE

REFER TO PLANS

PTD. GWBPTD. GWBPTD. GWB

G3

PENDANT LIGHT FIXTURE

WINDOW SHADE

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WALL BASE

REFER TO PLANS

PTD. GWBPTD. GWBPTD. GWB

WINDOW SHADE EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

WALL BASE

PENDANT LIGHT FIXTURE

WINDOW SHADE

PTD. GWB

WINDOW SHADE

WALL BASE

WALLCOVERING

WINDOW SHADE

WALL GRAZER LIGHT FIXTURE

GL-02 GL-02GL-02GL-03

EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

WINDOW SHADE

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WINDOW SHADE

WALL BASE

WALL GRAZER LIGHT FIXTURE

REFER TO PLANS

GL-02 WALLCOVERING

WALL BASE

EXISTING EXTERIOR CURTAIN WALLWINDOW SHADE

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

WINDOW SHADE

GL-03 GL-02

WINDOW SHADE

WALL BASE

WINDOW SHADE

WALLCOVERING

A-50-01

WCV-02

PT-03B

ST-02

WALL GRAZER LIGHT FIXTURE

GT-02

WCV-02

PT-03B4

5'-0"2'-0"

HK-2

HK-2

WCV-02

WALL GRAZER LIGHT FIXTURE

PT-03B

WCV-02

WV-01

ST-02

GL-07

/4

R

V L

3/4" RVL.

GT-02

A-50-01

WC-1

GT-02

WVWCV-02

GL-07

PUL

GT-02

PT-03B WV-01WV-01WV-01WV-01

PROVIDE

BLOCKING

FOR FUTURE

GRAB BAR

ADDITION

A-50-01

A-50-01

A-50-01

A87

A87A87

WCV-01

PT-03B

WALL GRAZER LIGHT FIXTURE

WCV-01

PT-03B

PROVIDE

BLOCKING FOR

GRAB BARS, TYP.

WC-1

8"TP-1

WALL GRAZER LIGHT FIXTURE

GB-3

GB-3

WALL BASE

WALLCOVERING

WINDOW SHADE

MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

WALL BASE

A-50-01

CREDENZA

REFER TO PLANS

WALLCOVERING

GL-02

WINDOW SHADE

WALL BASE

WALLCOVERING

WINDOW SHADE

GL-02 GL-02GL-02GL-03

EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

WINDOW SHADE EXISTING EXTERIOR CURTAIN WALL

PAINT EXISTING FIN TUBE RADIATORS

WITH ELECTROSTATIC PAINT, COLOR

TO MATCH ADJACENT WALL.

FWP

GL-06

MTL-02

MTL-02

WV-01

ST-02

GL-02

FWP

3/4" RVL.

3/4" RVL.

GL-02

A-50-01

3 EQ PANELS

GL-06

MTL-02

REVEALS

DOORS AND SIDELIGHTS

PTD. GWBREVEALSREVEALS

WALL BASE

CREDENZA

GL-02 GL-02

A-50-01

CREDENZA

WINDOW SHADE

GL-03 GL-02

GL-02 WALL BASE

EXISTING HISTORIC MARBLE

VINYL FILM

0 1' 2' 1 1/2"=1'-0"

KEY NOTES

GENERAL NOTES

LEGEND

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:4

P

M

A-20-11

ELEVATIONS - SECRETARY SUITE

RT + VW + SK

Checker

S E

N S

IT

IV

E B

U T

U N

C L

A S

S

IF

IE

D

S

B U

P

R O

P E

R T

Y O

F T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

N M

E N

T F

O R

O F

F

IC

E U

S E

O N

L Y

D o n o t re m o ve t h is n o ti ce

P ro p er ly d es tr o y o r re tu rn d o cu m en ts w h en n o lo n g er n ee d ed

1/4" = 1'-0"1

ELEVATION - OFFICE A

1/4" = 1'-0"2

ELEVATION - OFFICE A

1/4" = 1'-0"3

ELEVATION - OFFICE A

1/4" = 1'-0"4

ELEVATION - OFFICE A

1/4" = 1'-0"5

ELEVATION - OFFICE B (LVL 7)

1/4" = 1'-0"6

ELEVATION - OFFICE B (LVL 7)

1/4" = 1'-0"7

ELEVATION - OFFICE B (LVL 7)

1/4" = 1'-0"8

ELEVATION - OFFICE B (LVL 7)

1/4" = 1'-0"18

DEPUTY SEC CONF - WEST

1/4" = 1'-0"19

DEPUTY SEC CONF - SOUTH

1/4" = 1'-0"20

DEPUTY SEC CONF - EAST

1/4" = 1'-0"21

DEPUTY SEC CONF - NORTH

1/4" = 1'-0"22

DEPUTY SEC OFFICE - SOUTH

1/4" = 1'-0"23

DEPUTY SEC OFFICE - NORTH

1/4" = 1'-0"9

ELEV - RESTROOM

1/4" = 1'-0"10

ELEV - RESTROOM

1/4" = 1'-0"12

ELEV - RESTROOM

1/4" = 1'-0"13

ELEV - RESTROOM

1/4" = 1'-0"14

ELEV - RESTROOM

1/4" = 1'-0"15

ELEV - RESTROOM

1/4" = 1'-0"16

ELEV - RESTROOM

1/4" = 1'-0"17

ELEV - RESTROOM

1/4" = 1'-0"11

ELEV - RESTROOM

1/4" = 1'-0"27

SEC OFFICE CONF - SOUTH

1/4" = 1'-0"26

SEC OFFICE - WEST

1/4" = 1'-0"24

SEC OFFICE - SOUTH

1/4" = 1'-0"28

SEC OFFICE - EAST

1/4" = 1'-0"25

SEC OFFICE - NORTH

1/4" = 1'-0"30

SEC OFFICE CONF - WEST

1/4" = 1'-0"29

SEC OFFICE CONF - NORTH

G3 G3 / A-20-06

G5 G5 / A-20-06

A87 ALIGN WALL, WALL BASE AND FLOOR PORCELAIN

TILE GROUT JOINTS, TYP. REFER TO FINISH

FLOOR PLANS FOR WORKING POINTS

A102 PTD. GWB

A104 WALL GRAZER LIGHT FIXTURE

A105 WALL BASE

A106 PENDANT LIGHT FIXTURE

A109 MONITOR PROVIDED BY GC. SEE AV &

ELECTRICAL DRAWING.

A123 WALLCOVERING

A125 WINDOW SHADE

A126 REVEALS

A128 EXISTING EXTERIOR CURTAIN WALL

A129 PAINT EXISTING FIN TUBE RADIATORS WITH

ELECTROSTATIC PAINT, COLOR TO MATCH

ADJACENT WALL.

A130 DOORS AND SIDELIGHTS

A138 CREDENZA

LEVEL 3

48'-8 1/2"

LEVEL 4

60'-2 1/2"

LEVEL 5

71'-8 1/2"

PENTHOUSE FLOOR

107'-0 1/4"

LEVEL 6

83'-2 1/2"

LEVEL 7

94'-8 1/2"

NOT IN SCOPE

NOT IN SCOPE

A-30-01

V

IF

V

IF

V

IF

V

IF

FEDCBA

LEVEL FFE

EL=11'-6"

LEVEL FFE

EL=0'-0"

SECTIONS

1. REFER TO STRUCTURAL DRAWINGS FOR FRAMING AND FOUNDATION

DETAILS.

2. SEE ELEVATIONS & PLANS FOR MATERIAL FINISH AND LOCATIONS.

3. SEE FINISH SCHEDULE FOR FINISH REQUIREMENTS.

4. SEE PLANS FOR ASSEMBLY LOCATIONS AND LIFE SAFETY REQUIREMENTS.

5. DO NOT SCALE DRAWINGS.

0 8' 16' 1/8"=1'-0"

KEY NOTES

GENERAL NOTES

LEGEND

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:5

P

M

A-30-01

BUILDING SECTION

RT + VW + SK

AC + SP

S E

N S

IT

IV

E B

U T

U N

C L

A S

S

IF

IE

D

S

B U

P

R O

P E

R T

Y O

F T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

N M

E N

T F

O R

O F

F

IC

E U

S E

O N

L Y

D o n o t re m o ve t h is n o ti ce

P ro p er ly d es tr o y o r re tu rn d o cu m en ts w h en n o lo n g er n ee d ed

1/8" = 1'-0"1

BUILDING SECTION

1/2" = 1'-0"2

TYPICAL OPEN OFFICE SECTION

0 4' 8' 3/8"=1'-0"

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:3

P

M

A-40-01

TYPICAL OFFICE LAYOUTS

RT + VW + SK

AC + SP

FURNITURE LAYOUT - OFFICE C

FURNITURE LAYOUT - OFFICE B

FURNITURE LAYOUT - CONFERENCE (16 PERSON)

FURNITURE LAYOUT - CONFERENCE (12 PERSON)

FURNITURE LAYOUT -CONFERENCE (8 PERSON)

FURNITURE LAYOUT -CONFERENCE (4 PERSON)

FURNITURE LAYOUT -CONFERENCE (1 PERSON)

TYPICAL WORKSTATION LAYOUT

FURNITURE LAYOUT - OFFICE A

FURNITURE LAYOUT -CONFERENCE (10 PERSON)

FEC

X

D D

C C

A-40-02

A-40-02

A-40-02

A-40-02

SIM.

OPP.

SIM.

OPP.

SIM.

OPP.

DOOR NUMBERS

NOT IN SCOPE

NOT IN SCOPE

NOT IN SCOPE

NOT IN SCOPE

DOOR NUMBERS

DOOR NUMBERS

DOOR NUMBERS

3a

3a

20a

20a

F F

E E

D D

C C

B B

A A

A-40-02

1'-6 1/4" ± 7'-0" DOOR 1'-6 1/4" ±

10'-0 1/2" ±

1'-0 1/4" 7 3/4" 6'-8" GWB CLEARANCE 7 3/4" 1'-0 1/4"

/4

EQ. (5'-0"±) EQ. (5'-0"±)

/4

9'-9 1/2" ±

INSTALL MANUAL MAGNETIC

HOLDER FOR BOTH BOOR

LEAVES (NO ELECTRONIC

CONNECTION NEEDED)

INSTALL MANUAL MAGNETIC HOLDER FOR BOTH DOOR

LEAVES (NO ELECTRONIC CONNECTION NEEDED)

1B

1B

1B

1B 1B

1B

1B

NOT IN SCOPE OF WORK

EXISTING WALL, PARTITION,

OR COLUMN TO REMAIN

NEW WALL OR PARTITION

EXISTING DOOR TO BE REMAIN

NEW DOOR

RECESSED, SEMI RECESSED

AND FIRE RATED FIRE

EXTINGUISHERS. REFER TO

FEC SCHEDULE 5/A-51-01.

CONSTRUCTION PLAN

1. VERIFY ALL DIMENSIONS IN FIELD.

2. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BEGINNING WORK. NOTIFY

ARCHITECT IMMEDIATELY IF FIELD CONDITIONS DO NOT MATCH CONDITIONS

SHOWN ON DRAWINGS.

3. PROVIDE BLOCKING AT WALL MOUNTED ELEMENTS & FURNITURE, TYP.

4. REFER TO PARTITION TYPES FOR THICKNESSES OF PARTITIONS.

5. PARTITION DIMENSIONS ARE SHOWN TO FINISH FACE OF MATERIAL, TYP., U.N.O.

6. FURNITURE AND EQUIPMENT IS PROVIDED BY OWNER AND IS SHOWN FOR

COORDINATION PURPOSES ONLY, U.N.O.

7. ALL PENETRATIONS THROUGH FULL HEIGHT WALLS TO BE ACOUTICALLY SEALED.

8. ALL NEW WALLS TO BE FINISHED AND PREPPED FOR NOTED FINISH.

9. ANY BLOCKING TO BE FIRE RETARDANT, TYP.

10. ALL DOORS AT GYP. BD. PARTITIONS TO BE LOCATED 4" FROM EDGE OF JAMB TO

CORNER, UNLESS NOTED OTHERWISE.

11. TYPICAL PLANS (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS AND

DIMENSIONS. VERIFY ALL PARTITIONS, DOORS, EQUIPMENT, DEVICES, AND SPECIAL

CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

12. POWER & DATA DEVICES TO BE CENTERED ON WALL FACE / COLUMN FACE U.N.O.

13. PROVIDE SHALLOW BACK BOXES AT ALL LOCATIONS WITH LIMITED CAVITY SPACE.

14. COORDINATE DEVICES WITH AV, TELECOMMUNICATIONS, AND ELECTRICAL

DRAWINGS. COORDINATE WITH FURNITURE PROVIDED BY OWNER, TYP.

15. PRESERVE FIRE RATING AND STC RATING OF ALL EXT'G TO REMAIN PARTITIONS,

WALLS, PENETRATIONS, DOORS, ETC.

16. PROVIDE FLOOR TRANSITION THRESHOLD AT ALL EXISTING DOOR LOCATIONS.

THRESHOLD TO BE CENTERED UNDERNEATH DOOR LEAF, TYP. BOD: TARKETT CRS-

XX-A.

0 - - N.T.S.

TRUE NORTH

PLAN NORTH

KEY NOTES

GENERAL NOTES

LEGEND

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:3

P

M

A-40-02

ALTERNATE #5 - SHELTER-IN-PLACE DOORS

Author

Checker

S E

N S

IT

IV

E B

U T

U N

C L

A S

S

IF

IE

D

S

B U

P

R O

P E

R T

Y O

F T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

N M

E N

T F

O R

O F

F

IC

E U

S E

O N

L Y

D o n o t re m o ve t h is n o ti ce

P ro p er ly d es tr o y o r re tu rn d o cu m en ts w h en n o lo n g er n ee d ed

1/8" = 1'-0"2

ALTERNATE #5 - TYPICAL ENLARGED PLAN - LEVELS 3, 4, 6, & 7

1/16" = 1'-0"1

ALTERNATE #5 - PLAN

3/4" = 1'-0"3

ALTERNATE #5 - TYPICAL DETAIL PLAN

LEVEL 3 3BLV1-A

LEVEL 4 4BLV1-A

LEVEL 6 6BLV1-A

LEVEL 7 7BLV1-A

LEVEL 3 3BLV1-B

LEVEL 4 4BLV1-B

LEVEL 6 6BLV1-B

LEVEL 7 7BLV1-B

LEVEL 3 3BLV2-B

LEVEL 4 4BLV2-B

LEVEL 6 6BLV2-B

LEVEL 7 7BLV2-B

LEVEL 3 3BLV2-A

LEVEL 4 4BLV2-A

LEVEL 6 6BLV2-A

LEVEL 7 7BLV2-A

L V T

L V T L

VT

L

VT

L V T L V

L

VT

L V T L V

L V

L V

L

VT

RS

RS

RS

RS

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

T V

T V

T V

T V

FEC

SR

FEC

SR

F E

CR

F E

C R

FEC

SR

FEC

SR

T V

T V

T V

T V

TT

T T

C D

C D

C D

C D

F A

F A

FWP-02

F W

P -0

FWP-02

F W

P -0

F W

P -0

FWP-02

F W

P -0

FWP-02

FWP-02

F W

P -0

F W

P -0

FWP-02

F W

P -0

F W

P -0

F W

P -0

F W

P -0

F W

P -0

F W

P -0

FWP-02

FWP-02 FWP-02 FWP-02 FWP-02

FWP-02

S T

-0

P-3/RB-03P-3/RB-03 P-3/RB-03 P-3/RB-03 P-3/RB-03 P-3/RB-03 P-3/RB-03

P-3/RB-03 P-3/RB-03P-3/RB-03P-3/RB-03P-3/RB-03P-3/RB-03P-3/RB-03

S T

-0

S T

-0

S T

-0

P-3/RB-03

P-3/RB-03 P-3/RB-03

P-3/RB-03

P -3

R

B -0

P -3

R

B -0

P -3

R

B -0

P -3

R

B -0

S

S

S

S S S

S S

S S

S S

S

S

S

S

M M

MM

OS

OS

OS OS

OS

OSOSOSOS

OS OS OSOS

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

OS

FA

FAFA

FA FA

FA

FA

FA

F A

F A

OS

OSOS

OS

F A

F A

F A

F A

F A

F A

F A

F A

FEC

X

S

M

OS

SD

FA

SM

DS

US

FA

C

T

LV

RS

ABA

VS

CR

TV

H

J

A-20-03

A-20-04

9 6

CONFERENCE

CONFERENCE

CONFERENCE CONFERENCECONFERENCE

OFFICE OFFICEOFFICE OFFICE OFFICEOFFICEOFFICE

CONFERENCE

CONFERENCE

CONFERENCE CONFERENCE CONFERENCE CONFERENCE

OFFICEOFFICEOFFICE OFFICE

EAST ELEVATOR

LOBBY

CORRIDOR

WEST ELEVATOR

LOBBY

10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2"

10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2"

A-20-03

19 17

A-20-03

17 19

A-20-03

19 17

A-20-03

17 19

A-20-03

19 17

A-20-03

19 17

A-20-03

17 19

A-20-03

17 19

A-20-03

9 11

A-20-03

11 9

A-20-03

11 9

A-20-05

25 23

A-20-05

25 23

A-20-05

25 23

A-20-05

25 23

A-20-05

25 23

A-20-05

25 23

A-20-05

25 23

A-20-05

23 25

A-20-05

23 25

A-20-05

23 25

A-20-05

23 25

A-20-05

23 25

A-20-05

23 25

A-20-05

23 25

A-20-02

9 9

A-20-04

TELECOM ELECTRICAL

TELECOM ELECTRICAL

ELECTRICAL TELECOM

TELECOMELECTRICAL

NOT IN SCOPE NOT IN SCOPE

NOT IN SCOPE NOT IN SCOPE

OFFICEOFFICEOFFICE

3C

1B1B1B1B1B 1B

2B

2B 2B

2B

2B

2B

2B

2B

2B

1B1B1B1B1B 1B

2B

2B

2B

2B

2B

2B

2B

2B

11A

11B

3A

3A

11A

11A

11A

11A

3C 3C

3C 3C

2B

12 12 12 1212 12 12

12121212121212

ALIGN

ALIGN

ALIGN

ALIGN

11B 11B11B11B

A57

A57

A57

A57

11A

11A

11B11B

11B

11B 11A

11B 11B 11B

EQ EQ

EQ EQ

CONFERENCE

EQ EQ EQ EQ

A-51-02

A-51-02

A-51-02

A-51-02

A-51-02

OPP

OPP

A-51-02

A-51-02

A-51-0214

A-51-02

OPP

A-51-03

TYP.

A-51-03

TYP.

A-51-02

TYP.

A-51-03

TYP.

A-42-02

A-42-02

OPP.

10 11 12 13 14

D D

C C

9'-10 1/4" V.I.F. 25'-10" V.I.F. 25'-10" V.I.F. 9'-7 3/4" V.I.F.

35'-8 1/4" V.I.F. 25'-10" V.I.F. 9'-7 3/4" V.I.F.

TYP.

A-51-02

OPP.

OPP.

/4

V

IF

V

IF

/4

V

IF

V

IF

H

O L

D

/4

/4

/4

H

O L

D

5 5

5 5

"7

3C3C

3C

A101 A101A101 A101

A101 A101 A101

A101

A101

A101 A101A101

A101A101 A101A101

A57

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114 A114

A114

J6 A-62-03

J6 A-62-03

J6 A-62-03

J6 A-62-03

A-51-03

TYP.

EQ 5'-0" EQ

E Q

E Q

EQ 5'-0" EQ

E Q

E Q

EQ 5'-0" EQ

E Q

E Q

EQ 5'-0" EQ

E Q

E Q

A116

A119

A119A119

A119

EQ-3EQ-3EQ-3EQ-3

EQ-3EQ-3

EQ-3

EQ-3

A109

A109

A109A109

A109

A149

A149

A149

A149

OFFICEOFFICEOFFICE OFFICE OFFICE OFFICE OFFICE

CONFERENCECONFERENCECONFERENCECONFERENCE

CONFERENCE CONFERENCE CONFERENCE CONFERENCE

CONFERENCE

CORRIDOR

CONFERENCE

EAST ELEVATOR

LOBBY

WEST ELEVATOR

LOBBY

ACT-03

[10'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

OFFICE

OFFICE

OFFICEOFFICEOFFICEOFFICEOFFICE

CONFERENCE

CONFERENCE

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

B2

B2

A1A1 A1 A1

A1A1 A1 A1 A3

A3 A3

A3

B2

E2E2

E2

E2 E2

E2

D1

D1

D1

D1

D1

D1

D1

TELECOM ELECTRICAL

TELECOM ELECTRICAL

ELECTRICAL TELECOM

ELECTRICAL TELECOM

NOT IN SCOPE

NOT IN SCOPE

NOT IN SCOPE

NOT IN SCOPE

B2 B2 B2 B2 B2

B2 B2 B2 B2 B2 B2

A02

A02

A02

A02

A02

A02

A02

D1

GWB-01

[9'-0" AFF]

GWB-01

[9'-0" AFF]

A-50-02

A-50-02

E2 E2 E2 E2

F1F1F1F1 F1 F1 F1

F1F1F1F1F1F1F1F1

F1

EQ EQ

E Q

E Q

EQ EQ

E Q

E Q

E Q

E Q

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

A-50-02

E2E2

TYP.

TYP.

A65 A65

A65A65 A65A65A65A65A65

ACT-01

[9'-0" AFF]

ACT-01

[9'-0" AFF]

A-42-02

A-42-02

OPP.

11 12 13 14

D D

C C

EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ

D1

D1D1

D1

EQ EQ

E Q

E Q

EQ EQ

EQ EQ

E Q

E Q

EQ EQ

EQ EQEQ EQ

E Q

E Q

E Q

E Q

E Q

E Q

EQ EQEQ EQ

E Q

E Q

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

EQ 52'-0" EQ

EQ 52'-0" EQ

E Q

E Q

E Q

E Q

EQ EQ EQ EQEQ EQ

E Q

E Q

EQ EQEQ EQ

E Q

E Q

E Q

E Q

EQ EQ

EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ

E Q

E

Q

EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ EQ 6'-0" EQ

E Q

E

Q

E Q

E Q

EQ EQEQ EQE

Q

E Q

EQ EQE

Q

E Q

EQ EQ

E Q

E Q

EQ EQE

Q

E Q

EQ EQE

Q

E Q

3'-0" 3'-0"

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

E Q

E

Q E

Q

E

Q

E Q

E Q

EQ EQ

E Q

E Q

EQ EQ

E Q

E Q

EQ EQ

A65A65A65A65 A65

1'-0" EQ 5'-0" EQ 1'-0"

1'-0" EQ 5'-0" EQ 1'-0"

1'-0" EQ 5'-0" EQ 1'-0"

1'-0" EQ 5'-0" EQ 1'-0"

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E Q

E

Q

E

Q

E

Q

E

Q

E

Q

ACT-03

[10'-0" AFF]

A-50-02

A-50-02

TYP.

TYP.

A02

A02

EQ EQ

EQ EQ EQEQ EQ EQ

EQ EQ

A02

A02

A02

E Q

E

Q E

Q

E

Q

EQ 22'-0" EQ

EQ 22'-0" EQEQ 22'-0" EQE

Q

E

Q E

Q

E

Q

EQ 22'-0" EQ

A02

A02

ACCOUSTICAL

CEILING TILE

SUSPENDED GYPSUM

BOARD CEILING

ACCENT MATERIAL:

TBD

[X'-X" AFF] CEILING HEIGHT OR

SOFFIT HEIGHT A.F.F.

PAINT ALL EXPOSED

STRUCTURE, CONDUITS,

DUCTWORK, PIPING,

ETC. U.N.O.

EXP - EXPOSED CEILING

[EXP]

NOT IN SCOPE OF WORK

EXISTING WALL, PARTITION,

OR COLUMN TO REMAIN

NEW WALL OR PARTITION

EXISTING DOOR TO BE REMAIN

NEW DOOR

RECESSED, SEMI RECESSED

AND FIRE RATED FIRE

EXTINGUISHERS. REFER TO

FEC SCHEDULE 5/A-51-01.

MICROPHONE

SPEAKER

OCCUPANCY SENSOR

SMOKE DETECTOR

FIRE ALARM DEVICE

SOUND MASKING SYSTEM

SPRINKLER

EXIT SIGN

DAYLIGHT SENSOR

ULTRASONIC SENSOR

FIRE ALARM DEVICE -

WALL MOUNTED

SECURITY CAMERA

CPT-01

CPT-02

PL-01

WF-01

PT-01

CPT-03

RECESSED LED FIXTURE

SUSPENDED FIXTURE

AIR DIFFUSER

(SUPPLY, RETURN)

ACCESS PANEL. SEE MEP

DRAWINGS FOR ADDITIONAL

INFORMATION.

RECESSED LED

(DOWNLIGHT, WALL WASHER)

RECESSED LINEAR

(DOWNLIGHT, WALL WASHER)

OUTLET - DUPLEX

OUTLET - QUAD

DATA

SWITCH - SINGLE

THERMOSTAT -

WALL MOUNTED

LOW VOLTAGE DIMMER -

WALL MOUNTED

ROOM SCHEDULER -

WALL MOUNTED

ABA DOOR ACTUATOR

VACANCY SENSOR -

WALL MOUNTED

CARD READER

TELEVISION

POKE-THRU (QUAD

RECEPTACLE, HDMI, AND

2 DATA CONNECTIONS)

HDMI CONNECTION

POWER/ DATA WHIP TO

FURNITURE SYSTEM

CONSTRUCTION PLAN

1. VERIFY ALL DIMENSIONS IN FIELD.

2. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BEGINNING WORK. NOTIFY

ARCHITECT IMMEDIATELY IF FIELD CONDITIONS DO NOT MATCH CONDITIONS

SHOWN ON DRAWINGS.

3. PROVIDE BLOCKING AT WALL MOUNTED ELEMENTS & FURNITURE, TYP.

4. REFER TO PARTITION TYPES FOR THICKNESSES OF PARTITIONS.

5. PARTITION DIMENSIONS ARE SHOWN TO FINISH FACE OF MATERIAL, TYP., U.N.O.

6. FURNITURE AND EQUIPMENT IS PROVIDED BY OWNER AND IS SHOWN FOR

COORDINATION PURPOSES ONLY, U.N.O.

7. ALL PENETRATIONS THROUGH FULL HEIGHT WALLS TO BE ACOUTICALLY SEALED.

8. ALL NEW WALLS TO BE FINISHED AND PREPPED FOR NOTED FINISH.

9. ANY BLOCKING TO BE FIRE RETARDANT, TYP.

10. ALL DOORS AT GYP. BD. PARTITIONS TO BE LOCATED 4" FROM EDGE OF JAMB TO

CORNER, UNLESS NOTED OTHERWISE.

11. TYPICAL PLANS (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS AND

DIMENSIONS. VERIFY ALL PARTITIONS, DOORS, EQUIPMENT, DEVICES, AND SPECIAL

CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

12. POWER & DATA DEVICES TO BE CENTERED ON WALL FACE / COLUMN FACE U.N.O.

13. PROVIDE SHALLOW BACK BOXES AT ALL LOCATIONS WITH LIMITED CAVITY SPACE.

14. COORDINATE DEVICES WITH AV, TELECOMMUNICATIONS, AND ELECTRICAL

DRAWINGS. COORDINATE WITH FURNITURE PROVIDED BY OWNER, TYP.

15. PRESERVE FIRE RATING AND STC RATING OF ALL EXT'G TO REMAIN PARTITIONS,

WALLS, PENETRATIONS, DOORS, ETC.

16. PROVIDE FLOOR TRANSITION THRESHOLD AT ALL EXISTING DOOR LOCATIONS.

THRESHOLD TO BE CENTERED UNDERNEATH DOOR LEAF, TYP. BOD: TARKETT CRS-

XX-A.

REFLECTED CEILING PLAN

1. SEE FLOOR PLANS FOR DIMENSIONS.

2. COORDINATE ARCHITECTURAL REFLECTED CEILING PLAN WITH AV, MECHANICAL,

ELECTRICAL, FIRE ALARM, AND FIRE PROTECTION DRAWINGS. PROVIDE

COORDINATED DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTION.

3. CONTRACTOR SHALL LOCATE MECHANICAL ITEMS AROUND LIGHTING LAYOUT AND

IN THE APPROXIMATE LOCATION OF THE MECHANICAL DRAWINGS.

4. SUPPORT CONDUIT, BOXES AND OTHER EQUIPMENT WITH UNISTRUT HANGERS

ATTACHED TO STRUCTURAL ELEMENTS.

5. START POINT FOR CEILING GRIDS TO BE CENTER OF ROOM UNLESS NOTED BY A

START POINT.

6. PROVIDE NON-SAG TYPE GYPSUM BOARD PANELS AT CEILING OF ALL WET AREAS

SUCH AS TOILET ROOMS, UNLESS NOTED OTHERWISE.

7. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION REGARDING

SOFFIT HEIGHTS AND LOCATIONS.

8. COORDINATE LOCATION OF EXIT SIGNS WITH CODE COMPLIANCE PLANS,

ARCHITECTURAL DRAWINGS, AND ELECTRICAL DRAWINGS.

9. ROUTE ALL CONDUITS ON EXPOSED CEILINGS SQUARE TO BUILDING WALLS AND

GROUP TOGETHER.

10. ALL PARTITION AND SOFFIT FRAMING SHALL EXTEND TO UNDERSIDE OF

STRUCTURE, UNLESS NOTED OTHERWISE.

11. PROVIDE RADIUS FITTED CEILING TRACK ACCESSORY AT ALL BULLNOSED WALL

CORNERS.

12. LOCATE DEVICES AT CENTER LINE OF CEILING TILES, U.N.O.

13. TYPICAL RCPs (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS. VERIFY ALL

EQUIPMENT, DEVICES, AND SPECIAL CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

14. CONFIRM LOCATION OF SECURITION EQUIPMENT (I.E. CARD READERS, SECURITY

CAMERAS, ETC.) WITH OWNER & ARCHITECT PRIOR TO INSTALLATION.

CONTRACTOR TO PROVIDE CONDUIT IF REQUIRED.

FINISH PLAN

1. FOR FINISH MATERIAL WHEN MORE THAN ONE MATERIAL OCCURS THE FINISH IS

INDICATED THUS "/".

2. SEE INTERIOR ELEVATIONS AND PARTITION TYPES FOR ADDITIONAL FINISH

INFORMATION.

3. PAINT ALL INTERIOR AND EXTERIOR HOLLOW METAL DOORS, BORROWED LITES,

AND FRAMES.

4. PROVIDE TRANSITION STRIP AT ALL LOCATIONS WHERE FLOORING MATERIAL

CHANGES.

5. EXTEND SCHEDULED PAINT ON WALLS UP TO 1'-0" ABOVE THE FINISHED CEILING.

IN ROOMS NOT SCHEDULED TO RECEIVE A CEILING, EXTEND SCHEDULED PAINT

UP THE ENTIRE HEIGHT OF THE PARTITION, UNLESS NOTED OTHERWISE.

6. AT ALL EXPOSED AREAS, PAINT ALL WALLS, STRUCTURE, INCLUDING, BUT NOT

LIMITED TO, CONCRETE, COLUMNS, PIPING, CONDUIT, DUCTWORK AND OTHER

EQUIPMENT ETC.

7. DO NOT PAINT DOOR AND FRAME FIRE RATING LABELS.

8. PROVIDE LEVEL 4 DRYWALL FINISH AT ALL LOCATIONS SCHEDULED TO RECEIVE

PAINT UNLESS NOTED OTHERWISE.

9. EXCEPT FOR FACTORY FINISHED ITEMS, ALL EXPOSED MECHANICAL AND

ELECTRICAL EQUIPMENT, LOUVERS, PIPING, CONDUITS, ETC. SHALL BE PAINTED

UNLESS OTHERWISE NOTED. REFER TO SPECIFICATIONS FOR PAINTING SYSTEMS.

10. SEE REFLECTED CEILING PLANS FOR CEILING FINISHES.

11. TYPICAL FINISHES PER FLOOR U.N.O.

REFER TO MATERIAL SCHEDULE FOR VARIABLE FINISHES PER LEVEL: FLOOR:

CPT-01; BASE: RB-02; WALL PAINT: P-02; CEILING: P-01A; COVES & FASCIA: P-01A

12. TYPICAL FINISHES FOR EXISTING DOORS TO REMAIN:

EXISTING DOORS AND HOLLOW METAL FRAMES AT CORES TO MATCH ADJACENT

WALLS (P-3), U.N.O.

13. COVERPLATES FOR DEVICES / LIGHTSWITCHES ON FWP, ACCENT PAINT WALLS,

GLASS TILE, CV,WV OR GL PANELS TO BE MTL-02 STAINLESS STEEL.

0 4' 8' 1/4"=1'-0"

TRUE NORTH

PLAN NORTH

KEY NOTES

GENERAL NOTES

LEGEND

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:4

P

M

A-42-01

TYPICAL PLANS - CENTRAL CONFERENCE AREA

RT + VW + SK

AC + SP

1/4" = 1'-0"1

TYPICAL PLAN - CENTRAL CONFERENCE AREA

S E

N S

IT

IV

E B

U T

U N

C L

A S

S

IF

IE

D

S

B U

P

R O

P E

R T

Y O

F T

H E

U N

IT

E

D S

T A

T E

S G

O V

E R

N M

E N

T F

O R

O F

F

IC

E U

S E

O N

L Y

D o n o t re m o ve t h is n o ti ce

P ro p er ly d es tr o y o r re tu rn d o cu m en ts w h en n o lo n g er n ee d ed

1/4" = 1'-0"2

TYPICAL RCP - CENTRAL CONFERENCE AREA

A02 COVE LIGHT ABOVE CEILING, SEE LIGHTING SCHEDULE, DETAILS, AND ELECTRICAL

DRAWINGS.

A65 AIR RETURN SLOT TO RUN FULL LENGTH OF WALL, SEE DETAIL AS INDICATED &

MECHANICAL DRAWINGS.

A101 CENTER ELECTRICAL DEVICE IN WALL PANEL. SEE INTERIOR ELEVATION.

A109 MONITOR PROVIDED BY GC. SEE AV & ELECTRICAL DRAWING.

A114 CLEAN, PATCH, REPAIR, AND RE-FINISH EXT'G PARTITION.

A116 POLYMER-MODIFIED, SELF-LEVELING, HYDRAULIC CEMENT UNDERLAYMENT FOR

APPLICATION BELOW INTERIOR FLOOR COVERINGS. PREP, PRIME, & SEAL

CONCRETE SURFACE AS REQ'D. TYP. AT ALL FLOOR LOCATIONS IN SCOPE OF

WORK.

A119 EXISTING HISTORIC MARBLE (COVERED AND EXPOSED), PROTECT AS REQUIRED

DURING ALL PHASES OF WORK. DO NOT ALTER HISTORIC FINISHES. REMOVE

SURFACE APPLIED PRODUCTS INCLUDING INFORMATIONAL SIGNS, DISPENSING

DEVICES, ETC U.N.O. CLEAN, PATCH, AND REPAIR AS REQUIRED.

A149 MONITOR - OWNER PROVIDE, OWNER INSTALLED. SEE ELECTRICAL & AV DRAWINGS.

T

F A

G T

-0

S T

-0

ST-01

S T

-0

S T

-0

ST-01

S T

-0

P -3

/R B

-0

P -2

A T

S O

F F

IT

P -3

/R B

-0

OS

SD

SM

SM

SM

SM

SM

SM

OS

FA

FA

SD

SD

F A

FA

OS

OS

FEC

X

S

M

OS

SD

FA

SM

DS

US

FA

C

T

LV

RS

ABA

VS

CR

TV

H

J

A-20-04

ELEVATOR LOBBY

PANTRY

COPY

STAIR 3

FREIGHT ELEV.

LOBBY

NOT IN SCOPE

NOT IN SCOPE

/2

/4

/4

/2

1B1B

1A

1A

1A

1A

11D11D11D11D

11D 11D 11D 11D

14'-7 3/4" VIF 14'-9 1/4" VIF 5'-0" CLR. ± 1'-7 1/2"

14'-7 3/4" VIF 14'-9 1/4" VIF 5'-0" CLR.

CPT-01

A L

IG

N A

L

IG

N

14'-8" VIF 8'-6" 6'-4"

RF-01

RF-01

RF-01

DF-1

EQ-12

EQ-12

EQ-14

EQ-14

EQ-1

EQ-11

ALL LEVELS:

PL-01 FASCIA

PANELS

ABOVE EQ.

FULL HEIGHT

BACKSPLASHES:

LEVEL 3: GT-01A

LEVEL 4: GT-01B

LEVEL 6: GT-01C

LEVEL 7: GT-01D

ALL LEVELS:

COUNTER TOP -

SS-01

WDWK - PL-01

ALL LEVELS:

PL-01 FASCIA

PANELS

ABOVE EQ.

ALL LEVELS:

PL-01 FASCIA

PANEL ABOVE

VENDING

MACHINES TO

UNDERSIDE OF

SOFFIT

A-42-01

A-42-05A

D

C x x

EQ EQ EQ EQ

GL-08 GL-08GL-08GL-08GL-08

11D

EQ EQ EQ EQ

/4

/2

V

IF

/4

V

IF

/4

V

IF

/2

V

IF

/4

V

IF

/2

GL-08GL-08GL-08GL-08GL-08

3A

3A

3A

3A

11D

11B

DF-1

A-42-05A

A114

A114

A116

A-20-01

A-20-01

A-20-01

A-20-01 A-20-01A-20-01 54 6

A-20-04

9 6

A119

A119

A119

A119

A119

A119

A119

A119

A120

A120

A120

A-51-03

TYP.

E Q

M A

T E

R

IA

L W

ID

T

H E

Q

MATERIAL JOINT

MATERIAL JOINT

A-51-02

TYP.

A-51-02

TYP.

TYP.

OPP.

A145 A145

A145A145

A149

ELEVATOR LOBBY

PANTRY

COPY

F2

G W

B -0

[7

A F

F

GWB-01

[7'-6" AFF]

GWB-01

[7'-6" AFF]

STAIR 3

FREIGHT ELEV.

LOBBY

F1

F1

F1

F1

F1

F1

F1

F1

F1

F2 F2

F2 F2 ACT-01

[8'-6" AFF]

GWB-01

[9'-0" AFF]

ACT-01

[9'-0" AFF]

F2F2 F2 F2

F2 F2F2F2

F2

E1

E Q

E Q

2'-0" 2'-0"

2'-0" 2'-0"

2'-0"

EQ EQ

EQ EQ

2'-0"

NOT IN SCOPE

NOT IN SCOPE

P-02

P-02

P-02

P-02

A-42-01

A-42-05B

F1

D

C x x

E Q

E

Q

18'-0"

E Q

E

Q

F2F2F2F2

EQ EQ EQ EQ EQ EQ EQ EQ

EQ EQ EQ EQ EQ EQ EQ EQ

E Q

E Q

EQ EQ

GWB-01

[8'-6" AFF]

GWB-01

[8'-6" AFF]

F2 F2 F2 F2

G W

B -0

[7

A F

F

F1F1F1F1F1

A-42-05B

A L

IG

N

E Q

E

Q

F2

F2

F2

F2

F2

F2

GWB-01

[7'-6" AFF]

6"

A L

IG

N T

Y P

A

L

IG

N

T Y

P

CONSTRUCTION PLAN

1. VERIFY ALL DIMENSIONS IN FIELD.

2. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BEGINNING WORK. NOTIFY

ARCHITECT IMMEDIATELY IF FIELD CONDITIONS DO NOT MATCH CONDITIONS

SHOWN ON DRAWINGS.

3. PROVIDE BLOCKING AT WALL MOUNTED ELEMENTS & FURNITURE, TYP.

4. REFER TO PARTITION TYPES FOR THICKNESSES OF PARTITIONS.

5. PARTITION DIMENSIONS ARE SHOWN TO FINISH FACE OF MATERIAL, TYP., U.N.O.

6. FURNITURE AND EQUIPMENT IS PROVIDED BY OWNER AND IS SHOWN FOR

COORDINATION PURPOSES ONLY, U.N.O.

7. ALL PENETRATIONS THROUGH FULL HEIGHT WALLS TO BE ACOUTICALLY SEALED.

8. ALL NEW WALLS TO BE FINISHED AND PREPPED FOR NOTED FINISH.

9. ANY BLOCKING TO BE FIRE RETARDANT, TYP.

10. ALL DOORS AT GYP. BD. PARTITIONS TO BE LOCATED 4" FROM EDGE OF JAMB TO

CORNER, UNLESS NOTED OTHERWISE.

11. TYPICAL PLANS (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS AND

DIMENSIONS. VERIFY ALL PARTITIONS, DOORS, EQUIPMENT, DEVICES, AND SPECIAL

CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

12. POWER & DATA DEVICES TO BE CENTERED ON WALL FACE / COLUMN FACE U.N.O.

13. PROVIDE SHALLOW BACK BOXES AT ALL LOCATIONS WITH LIMITED CAVITY SPACE.

14. COORDINATE DEVICES WITH AV, TELECOMMUNICATIONS, AND ELECTRICAL

DRAWINGS. COORDINATE WITH FURNITURE PROVIDED BY OWNER, TYP.

15. PRESERVE FIRE RATING AND STC RATING OF ALL EXT'G TO REMAIN PARTITIONS,

WALLS, PENETRATIONS, DOORS, ETC.

16. PROVIDE FLOOR TRANSITION THRESHOLD AT ALL EXISTING DOOR LOCATIONS.

THRESHOLD TO BE CENTERED UNDERNEATH DOOR LEAF, TYP. BOD: TARKETT CRS-

XX-A.

REFLECTED CEILING PLAN

1. SEE FLOOR PLANS FOR DIMENSIONS.

2. COORDINATE ARCHITECTURAL REFLECTED CEILING PLAN WITH AV, MECHANICAL,

ELECTRICAL, FIRE ALARM, AND FIRE PROTECTION DRAWINGS. PROVIDE

COORDINATED DRAWINGS FOR REVIEW PRIOR TO CONSTRUCTION.

3. CONTRACTOR SHALL LOCATE MECHANICAL ITEMS AROUND LIGHTING LAYOUT AND

IN THE APPROXIMATE LOCATION OF THE MECHANICAL DRAWINGS.

4. SUPPORT CONDUIT, BOXES AND OTHER EQUIPMENT WITH UNISTRUT HANGERS

ATTACHED TO STRUCTURAL ELEMENTS.

5. START POINT FOR CEILING GRIDS TO BE CENTER OF ROOM UNLESS NOTED BY A

START POINT.

6. PROVIDE NON-SAG TYPE GYPSUM BOARD PANELS AT CEILING OF ALL WET AREAS

SUCH AS TOILET ROOMS, UNLESS NOTED OTHERWISE.

7. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION REGARDING

SOFFIT HEIGHTS AND LOCATIONS.

8. COORDINATE LOCATION OF EXIT SIGNS WITH CODE COMPLIANCE PLANS,

ARCHITECTURAL DRAWINGS, AND ELECTRICAL DRAWINGS.

9. ROUTE ALL CONDUITS ON EXPOSED CEILINGS SQUARE TO BUILDING WALLS AND

GROUP TOGETHER.

10. ALL PARTITION AND SOFFIT FRAMING SHALL EXTEND TO UNDERSIDE OF

STRUCTURE, UNLESS NOTED OTHERWISE.

11. PROVIDE RADIUS FITTED CEILING TRACK ACCESSORY AT ALL BULLNOSED WALL

CORNERS.

12. LOCATE DEVICES AT CENTER LINE OF CEILING TILES, U.N.O.

13. TYPICAL RCPs (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS. VERIFY ALL

EQUIPMENT, DEVICES, AND SPECIAL CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

14. CONFIRM LOCATION OF SECURITION EQUIPMENT (I.E. CARD READERS, SECURITY

CAMERAS, ETC.) WITH OWNER & ARCHITECT PRIOR TO INSTALLATION.

CONTRACTOR TO PROVIDE CONDUIT IF REQUIRED.

ACCOUSTICAL

CEILING TILE

SUSPENDED GYPSUM

BOARD CEILING

ACCENT MATERIAL:

TBD

[X'-X" AFF] CEILING HEIGHT OR

SOFFIT HEIGHT A.F.F.

PAINT ALL EXPOSED

STRUCTURE, CONDUITS,

DUCTWORK, PIPING,

ETC. U.N.O.

EXP - EXPOSED CEILING

[EXP]

CPT-01

CPT-02

PL-01

WF-01

PT-01

CPT-03

NOT IN SCOPE OF WORK

EXISTING WALL, PARTITION,

OR COLUMN TO REMAIN

NEW WALL OR PARTITION

EXISTING DOOR TO BE REMAIN

NEW DOOR

RECESSED, SEMI RECESSED

AND FIRE RATED FIRE

EXTINGUISHERS. REFER TO

FEC SCHEDULE 5/A-51-01.

RECESSED LED FIXTURE

SUSPENDED FIXTURE

AIR DIFFUSER

(SUPPLY, RETURN)

ACCESS PANEL. SEE MEP

DRAWINGS FOR ADDITIONAL

INFORMATION.

RECESSED LED

(DOWNLIGHT, WALL WASHER)

RECESSED LINEAR

(DOWNLIGHT, WALL WASHER)

FINISH PLAN

1. FOR FINISH MATERIAL WHEN MORE THAN ONE MATERIAL OCCURS THE FINISH IS

INDICATED THUS "/".

2. SEE INTERIOR ELEVATIONS AND PARTITION TYPES FOR ADDITIONAL FINISH

INFORMATION.

3. PAINT ALL INTERIOR AND EXTERIOR HOLLOW METAL DOORS, BORROWED LITES,

AND FRAMES.

4. PROVIDE TRANSITION STRIP AT ALL LOCATIONS WHERE FLOORING MATERIAL

CHANGES.

5. EXTEND SCHEDULED PAINT ON WALLS UP TO 1'-0" ABOVE THE FINISHED CEILING.

IN ROOMS NOT SCHEDULED TO RECEIVE A CEILING, EXTEND SCHEDULED PAINT

UP THE ENTIRE HEIGHT OF THE PARTITION, UNLESS NOTED OTHERWISE.

6. AT ALL EXPOSED AREAS, PAINT ALL WALLS, STRUCTURE, INCLUDING, BUT NOT

LIMITED TO, CONCRETE, COLUMNS, PIPING, CONDUIT, DUCTWORK AND OTHER

EQUIPMENT ETC.

7. DO NOT PAINT DOOR AND FRAME FIRE RATING LABELS.

8. PROVIDE LEVEL 4 DRYWALL FINISH AT ALL LOCATIONS SCHEDULED TO RECEIVE

PAINT UNLESS NOTED OTHERWISE.

9. EXCEPT FOR FACTORY FINISHED ITEMS, ALL EXPOSED MECHANICAL AND

ELECTRICAL EQUIPMENT, LOUVERS, PIPING, CONDUITS, ETC. SHALL BE PAINTED

UNLESS OTHERWISE NOTED. REFER TO SPECIFICATIONS FOR PAINTING SYSTEMS.

10. SEE REFLECTED CEILING PLANS FOR CEILING FINISHES.

11. TYPICAL FINISHES PER FLOOR U.N.O.

REFER TO MATERIAL SCHEDULE FOR VARIABLE FINISHES PER LEVEL: FLOOR:

CPT-01; BASE: RB-02; WALL PAINT: P-02; CEILING: P-01A; COVES & FASCIA: P-01A

12. TYPICAL FINISHES FOR EXISTING DOORS TO REMAIN:

EXISTING DOORS AND HOLLOW METAL FRAMES AT CORES TO MATCH ADJACENT

WALLS (P-3), U.N.O.

13. COVERPLATES FOR DEVICES / LIGHTSWITCHES ON FWP, ACCENT PAINT WALLS,

GLASS TILE, CV,WV OR GL PANELS TO BE MTL-02 STAINLESS STEEL.

MICROPHONE

SPEAKER

OCCUPANCY SENSOR

SMOKE DETECTOR

FIRE ALARM DEVICE

SOUND MASKING SYSTEM

SPRINKLER

EXIT SIGN

DAYLIGHT SENSOR

ULTRASONIC SENSOR

FIRE ALARM DEVICE -

WALL MOUNTED

SECURITY CAMERA

OUTLET - DUPLEX

OUTLET - QUAD

DATA

SWITCH - SINGLE

THERMOSTAT -

WALL MOUNTED

LOW VOLTAGE DIMMER -

WALL MOUNTED

ROOM SCHEDULER -

WALL MOUNTED

ABA DOOR ACTUATOR

VACANCY SENSOR -

WALL MOUNTED

CARD READER

TELEVISION

POKE-THRU (QUAD

RECEPTACLE, HDMI, AND

2 DATA CONNECTIONS)

HDMI CONNECTION

POWER/ DATA WHIP TO

FURNITURE SYSTEM

0 4' 8' 1/4"=1'-0"

SENSITIVE BUT UNCLASSIFIED (SBU) PROPERTY OF THE UNITED STATES GOVERNMENT COPYING, DISSEMINATION, OR DISTRIBUTION OF THIS DOCUMENT TO UNAUTHORIZED RECIPIENTS IS PROHIBITED.

Do not remove this notice. Properly destroy or return documents when no longer needed.

TRUE NORTH

PLAN NORTH

CHECKED BY

DRAWN BY

FLOOR NUMBER

DRAWING TITLE

SHEET

NUMBER

SUBMISSION DATE

SUBMISSION STAGE

GSA PM

GSA PROJECT NO.

PROJECT

DESCRIPTION

PROJECT TITLE

BUILDING NAME

ADDRESS

BUILDING NUMBER

PRIME CONTR. NO.

PRIME ORDER NO.

CONST. CONTR.

A/E

SUB A/E

CONST. CONTR. NO.

SHEET SIZE:

DATE DRAWN:

36 X 48

S H

E E

T

ID

E N

TI

FI

C A

TI

O

N

DISCIPLINE

P R

O

JE

C T

ID

E

N

TI

FI

C

A

TI

O N

B U

IL

D

IN

G

BIM FILE NAME

C O

N

TR

A C

TO

R

S R

E V

IS

IO

N B

LO

C

K G

R A

P H

IC

S

C A

LE

K

E Y

P

LA

N S

TA

M

P O

R S

E A

L D

E S

IG

N

E R

ID

E

N

TI

FI

C

A

TI

O N

O W

N E

R

ID

E N

TI

FI

C A

TI

O

N

SHEET OF SHEETS

KRUECK & SEXTON ARCHITECTS, P.C.

400 MARYLAND AVENUE, SW

WASHINGTON, DC 20024

LYNDON B. JOHNSON FEDERAL BUILDING

DC0010ZZ

DC0010_A_3-4-6-7_r2020.rvt

WSP ENGINEERING

DEPARTMENT OF EDUCATION

CONSOLIDATION PROJECT

ISSUED FOR BID

HALLIE FUTTERMAN

RENOVATION OF FLOORS 3, 4, 6, & 7 OF THE EXISTING

BUILDING TO MEET THE DEPARTMENT OF

EDUCATION’S PROGRAMMATIC REQUIREMENTS.

GS-07-P-16-UC-D-7000

47PM0520F0002

47PM0520F0002

KRUECK & SEXTON ARCHITECTS

221 W ERIE ST

CHICAGO, IL 60654 (312) 787-0056

ARCHITECT

WSP ENGINEERING

ONE PENNSYLVANIA PLAZA, SECOND FLOOR

NEW YORK, NY 10119 (212) 465-5000

MEP ENGINEER

ATELIER TEN

45 E 20TH ST, 4TH FLOOR

NEW YORK, NY 10003 (312) 386-1400

SUSTAINABILITY CONSULTANT

THRESHOLD ACOUSTICS

141 W JACKSON BLVD, SUITE 2080

CHICAGO, IL 60604 (312) 386-1400

ACOUSTIC CONSULTANT

WEST EAST

M A

TC

H

LI

N

E

GENERAL NOTESLEGEND KEY NOTES

GENERAL SERVICES ADMINISTRATION

NATIONAL CAPITAL REGION

PUBLIC BUILDING SERVICE, D.C. SERVICES DIV.

7TH & D STREET, S.W.

WASHINGTON, D.C. 20407

ISSUE

NO. DATE ISSUE

ARCHITECTURAL

VARIES, SEE DRAWINGS

01 04/23/2021 ISSUED FOR BID

04/23/2021

2020 - 2021

FORCADE DESIGN

1626 PAYNE STREET

EVANSTON, IL 60201 (847) 448-4270

ENVIRONMENTAL GRAPHICS CONSULTANT

/2

/2

:2

:5

P

M

A-42-02

TYPICAL PLANS - ELEVATOR LOBBY & PANTRY

RT + VW + SK

AC + SP

1/4" = 1'-0"1

TYPICAL PLAN - ELEVATOR LOBBY & PANTRY

1/4" = 1'-0"2

TYPICAL RCP - ELEVATOR LOBBY & PANTRY

A114 CLEAN, PATCH, REPAIR, AND RE-FINISH EXT'G PARTITION.

A116 POLYMER-MODIFIED, SELF-LEVELING, HYDRAULIC CEMENT UNDERLAYMENT FOR

APPLICATION BELOW INTERIOR FLOOR COVERINGS. PREP, PRIME, & SEAL

CONCRETE SURFACE AS REQ'D. TYP. AT ALL FLOOR LOCATIONS IN SCOPE OF

WORK.

A119 EXISTING HISTORIC MARBLE (COVERED AND EXPOSED), PROTECT AS REQUIRED

DURING ALL PHASES OF WORK. DO NOT ALTER HISTORIC FINISHES. REMOVE

SURFACE APPLIED PRODUCTS INCLUDING INFORMATIONAL SIGNS, DISPENSING

DEVICES, ETC U.N.O. CLEAN, PATCH, AND REPAIR AS REQUIRED.

A120 FLOOR TRANSITION, SEE DETAIL.

A121 MATERIAL JOINT

A145 PAINT EXISTING ELEVATOR DOORS & FRAMES WITH ELECTROSTATIC PAINT, COLOR:

TBD. ; MAINTAIN ELEVATOR NUMBERING (RAISED & TOP FRAME)

A149 MONITOR - OWNER PROVIDE, OWNER INSTALLED. SEE ELECTRICAL & AV DRAWINGS.

RS

RS

L

VT

LV

L V

C D

L V

C D

LV

T

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

V S

TV

TV

F E

C R

F E

CR

T V

T V

T

VS VS VS VS

VS VS VS VS

T T

TT

F W

P -0

F W

P -0

F

W P

-0

F W

P -0

FWP-05FWP-06

F W

P -0

FWP-06

F W

P -0

FWP-06

F W

P -0

F W

P -0

FWP-06

F W

P -0

F W

P -0

FWP-06 FWP-06

F W

P -0

F W

P -0

FWP-06 FWP-06

P-3/RB-03 P-3/RB-03 P-3/RB-03

P-3/RB-03 P-3/RB-03 P-3/RB-03

P-3/RB-03P-3/RB-03P-3/RB-03

P-3/RB-03P-3/RB-03P-3/RB-03

P -3

/R B

-0

FWP-05

FWP-05

FWP-05

S S

S S

M

M

S S

OS

OS

OS

OS

OS

OS

OS

OS

FA FA

FA

FA

FA

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

SM

FA

FA

FA

OS

OS

M

S S

S

S

S

S

S

S

M

OS

FA

FA

FAFA

FA FAOS

FA

FA

FA

F A

FEC

X

S

M

OS

SD

FA

SM

DS

US

FA

C

T

LV

RS

ABA

VS

CR

TV

H

J

A-20-03

A-20-03

A-20-03

13 15

A-20-01

A-20-01

A-20-02

CORRIDOR

CORRIDOR

OFFICEOFFICEOFFICE

AV CLOSET

FOCUS FOCUS

CONFERENCE

FOCUS

FOCUS FOCUS FOCUS

HUDDLE ROOM

CONFERENCE

HUDDLE ROOM

FOCUSFOCUS

OFFICE OFFICE OFFICE

OFFICEOFFICEOFFICE

2A2A

2A2A

2B

2B

2C

2C

1B 1B

1B

1B

1B

1B

1B

1B

1B

1B

1B

1B

1C 2C

1C

2C

1C

1C1B

2B 2B

2B 2B

A-20-03

31 29

A-20-03

29 31

A-20-03

31 29

A-20-03

29 31

A-20-03

31 29

32 A-20-03

31 29

A-20-03

29 31

A-20-05

A-20-05

A-20-05

A-20-05

A-20-05

A-20-05

A-20-05

A-20-05

22A-20-05

A-20-05

A-20-05

A-20-05

OFFICEOFFICEOFFICE

A-20-03

A-20-03

12 12 121212 12

12 12 12 12 12 12

10'-2" 10'-2" 10'-2" 10'-2" 10'-2" 10'-2"

10'-2" 10'-2" 10'-2"

H

O L

D

/2

/4

H

O L

D

ALIGN

18'-4 1/4" 6'-0 3/4" 6'-1" 11'-2 1/2" 8'-6 1/2" 7'-5 1/2" 14'-6"

CPT-01

CPT-01

A-51-02

OPP

SIM

A-51-02

OPP

SIM

A-51-02

OPP

SIM 33

A-51-02

OPP

SIM

A-51-03

TYP.

A-51-02

TYP.

A-51-03

TYP.

A-51-03

TYP.

A-42-05A

A-42-09

A-42-08

10'-2" 10'-2" 10'-2"

3a 4 5 6

D D

C C

/4

V .I .F

V

.I .F

V .I .F

24'-5" V.I.F. 25'-10" V.I.F. 21'-11 1/2" V.I.F.

/4

V .I .F

V

.I .F

V .I .F

H

O L

D

/2

/4

H

O L

D

11B

11B 11B

11B 11B

11B 11B

11B

11B

2A

2A 2A

11B 11B

LEVEL 3, 4

LEVEL 6

6'-1" 11'-2 1/2" 8'-6 1/2"

A101 A101 A101

E Q

E Q

"7

E Q

E Q

"7

1C1C

A101A101 A101

OPP.1

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

A114

EQ EQ

E Q

E

Q

7'-5 1/2"

A101

A101

A101

A101

A116

A-51-02

SIM.

A-51-02

SIM.

EQ EQ EQ EQ

EQ EQ EQ EQ

EQ-4

EQ-4

EQ-4

EQ-4

A109

A101

A101

A109

A149

A149

4'-0"

OFFICEOFFICE OFFICEOFFICE OFFICEOFFICE

OFFICE

OFFICE OFFICEOFFICE OFFICEOFFICE

CONFERENCE

CONFERENCE

HUDDLE ROOM

HUDDLE ROOM

FOCUS FOCUS

FOCUS FOCUS

FOCUS

FOCUS FOCUS

FOCUS

CORRIDOR

CORRIDOR

CORRIDOR

AV CLOSET

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

ACT-01

[9'-0" AFF]

ACT-01

[9'-0" AFF]

ACT-03

[10'-0" AFF]

ACT-02

[8'-6" AFF]

ACT-02

[8'-6" AFF]

B2

A1

A1

F1

F1

F1F1

D1D1

F1

F1 F1

F1 F1

F1F1

F1 F1

F1 F1

F1F1

F1

F1 F1

B2 B2 B2 B2 B2 B2

B2 B2B2B2B2

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

A5

E2E2

E2

E2 E2

A02 A02

E2

E2

ACT-02

[9'-0" AFF]

ACT-02

[9'-0" AFF]

A-50-02

TYP.

A-50-02

TYP.

A65 A65A65 A65A65 A65

A65A65A65A65A65A65

A-42-05B

A-42-09

A-42-08

GWB-01

[9'-0" AFF]

GWB-01

[9'-0" AFF]

3a 4 5 6

D D

C C

EQ EQ

E Q

E Q

2'-0" 5 1/2"

ALIGN

ALIGN

ALIGN

EQ EQ

E Q

E Q

EQ 10'-0" EQ

ALIGN

F1 F1 E2

F1

E2

F1 F1

EQ1 6'-0" EQ1EQ1 6'-0" EQ1EQ1 6'-0" EQ1EQ2 EQ2 EQ2 EQ2EQ1 6'-0" EQ1EQ1 6'-0" EQ1EQ1 6'-0" EQ1

E Q

E Q

E Q

E Q

EQ2 EQ2 EQ2 EQ2EQ1 6'-0" EQ1EQ1 6'-0" EQ1EQ1 6'-0" EQ1 EQ1 6'-0" EQ1 EQ1 6'-0" EQ1 EQ1 6'-0" EQ1

E Q

E

Q

EQ 14'-0" EQ

E Q

E Q

EQ EQEQ EQ

E Q

E Q

E Q

E Q

EQ EQEQ EQ

E Q

E Q

EQ EQ

E Q

E Q

EQ EQ

E Q

E Q

F1 F1

E2 E2 EQ EQ

E Q

E Q

EQ EQ

E Q

E Q

D1

D1

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

A L

IG

N

1'-0" EQ 5'-0" EQ 1'-0"

1'-0" EQ 5'-0" EQ 1'-0"

E Q

E Q

EQ EQ

E Q

E

Q EQ EQ

E Q

E

Q EQ EQ

E Q

E

Q

E Q

E

Q

E Q

E Q

E Q

E

Q EQ EQEQ EQEQ EQ

E Q

E Q

E Q

E

Q

E Q

E

Q

E Q

E

Q

E Q

E

Q

LEVEL 3, 4

LEVEL 6

E Q

E

Q

E Q

E

Q

2'-0" 2'-0"

ALIGNALIGN

A02

A02 A02

A02

A2 E2

E Q

E

Q

E Q

E

Q

A-50-02

A-50-02

TYP.

TYP.

A148 A148

A154 A154

ACCOUSTICAL

CEILING TILE

SUSPENDED GYPSUM

BOARD CEILING

ACCENT MATERIAL:

TBD

[X'-X" AFF] CEILING HEIGHT OR

SOFFIT HEIGHT A.F.F.

PAINT ALL EXPOSED

STRUCTURE, CONDUITS,

DUCTWORK, PIPING,

ETC. U.N.O.

EXP - EXPOSED CEILING

[EXP]

NOT IN SCOPE OF WORK

EXISTING WALL, PARTITION,

OR COLUMN TO REMAIN

NEW WALL OR PARTITION

EXISTING DOOR TO BE REMAIN

NEW DOOR

RECESSED, SEMI RECESSED

AND FIRE RATED FIRE

EXTINGUISHERS. REFER TO

FEC SCHEDULE 5/A-51-01.

MICROPHONE

SPEAKER

OCCUPANCY SENSOR

SMOKE DETECTOR

FIRE ALARM DEVICE

SOUND MASKING SYSTEM

SPRINKLER

EXIT SIGN

DAYLIGHT SENSOR

ULTRASONIC SENSOR

FIRE ALARM DEVICE -

WALL MOUNTED

SECURITY CAMERA

CPT-01

CPT-02

PL-01

WF-01

PT-01

CPT-03

RECESSED LED FIXTURE

SUSPENDED FIXTURE

AIR DIFFUSER

(SUPPLY, RETURN)

ACCESS PANEL. SEE MEP

DRAWINGS FOR ADDITIONAL

INFORMATION.

RECESSED LED

(DOWNLIGHT, WALL WASHER)

RECESSED LINEAR

(DOWNLIGHT, WALL WASHER)

CONSTRUCTION PLAN

1. VERIFY ALL DIMENSIONS IN FIELD.

2. VERIFY EXISTING CONDITIONS IN THE FIELD PRIOR TO BEGINNING WORK. NOTIFY

ARCHITECT IMMEDIATELY IF FIELD CONDITIONS DO NOT MATCH CONDITIONS

SHOWN ON DRAWINGS.

3. PROVIDE BLOCKING AT WALL MOUNTED ELEMENTS & FURNITURE, TYP.

4. REFER TO PARTITION TYPES FOR THICKNESSES OF PARTITIONS.

5. PARTITION DIMENSIONS ARE SHOWN TO FINISH FACE OF MATERIAL, TYP., U.N.O.

6. FURNITURE AND EQUIPMENT IS PROVIDED BY OWNER AND IS SHOWN FOR

COORDINATION PURPOSES ONLY, U.N.O.

7. ALL PENETRATIONS THROUGH FULL HEIGHT WALLS TO BE ACOUTICALLY SEALED.

8. ALL NEW WALLS TO BE FINISHED AND PREPPED FOR NOTED FINISH.

9. ANY BLOCKING TO BE FIRE RETARDANT, TYP.

10. ALL DOORS AT GYP. BD. PARTITIONS TO BE LOCATED 4" FROM EDGE OF JAMB TO

CORNER, UNLESS NOTED OTHERWISE.

11. TYPICAL PLANS (1/4" = 1'-0" DRAWINGS) SHOW TYPICAL CONDITIONS AND

DIMENSIONS. VERIFY ALL PARTITIONS, DOORS, EQUIPMENT, DEVICES, AND SPECIAL

CONDITIONS IN 1/8" = 1'-0" DRAWINGS.

12. POWER & DATA DEVICES TO BE CENTERED ON WALL FACE / COLUMN FACE U.N.O.

13. PROVIDE SHALLOW BACK BOXES AT ALL LOCATIONS WITH LIMITED CAVITY SPACE.

14. COORDINATE DEVICES WITH AV, TELECOMMUNICATIONS, AND ELECTRICAL

DRAWINGS. COORDINATE WITH FURNITURE PROVIDED BY OWNER, TYP.

15. PRESERVE FIRE RATING AND STC RATING OF ALL EXT'G TO REMAIN PARTITIONS,

WALLS, PENETRATIONS, DOORS, ETC.

16. PROVIDE FLOOR TRANSITION THRESHOLD AT ALL EXISTING DOOR LOCATIONS.

THRESHOLD TO BE CENTERED UNDERNEATH DOOR LEAF, TYP. BOD: TARKETT CRS-

XX-A.

REFLECTED CEILING PLAN

1. SEE FLOOR PLANS FOR DIMENSIONS.

2. COORDINATE ARCHITECTURAL REFLECTED CEILING PLAN WITH AV, MECHANICAL,

ELECTRICAL, FIRE ALARM, AND FIRE PROTECTION DRAWINGS. PROVIDE

COORDINATED DRAWINGS FOR…