C-Fire Protection- Part 2.pdf

PDF 4 MB Posted

Attached to
36C10F24R50018 Balance of Work VAMC Manhattan, NY -- Y1DA
Solicitation number
QSE--36C10F24R50018
Issued by

About this file

This document provides details for a federal contract opportunity to construct balance of work at the Veterans Affairs Medical Center in Manhattan, New York. The solicitation number is 36C10F24R50018 and is being issued by the Department of Veterans Affairs Office of Construction and Facilities Management. The opportunity involves constructing remaining hurricane recovery work at the VAMC Manhattan campus to complete recovery from Hurricane Sandy. Response is due by the date listed on the solicitation. Products and services required include all remaining construction work to finish hurricane recovery efforts at the medical center.

View the file

Other files

File Type Posted
SolicitationCancellation.pdf PDF
SolicitationAmendment0006.pdf PDF
Manhattan VA Asbestos Survey Report 05-2021final (5-24-21).pdf PDF
Manhattan VA Revised Asbestos Survey Report 05-2021Final (Appendix H - First Half).pdf PDF
QA - Balance of Work - 05.08.2024.pdf PDF
Manhattan VA Revised Asbestos Survey Report 05-2021Final (Appendix H - 2nd half).pdf PDF
QA - Balance of Work - 05.02.2024.pdf PDF
SolicitationAmendment0005.pdf PDF
SolicitationAmendment0004.pdf PDF
QA - Balance of Work - 04.16.2024.pdf PDF
C-Mechanical- Part 2.pdf PDF
C-Electrical- Part 5.pdf PDF
B-Mechanical-Part 1.pdf PDF
P03_CDR- Sole Source JA - Access Controls - 11-16-22.pdf PDF
B-Civil.pdf PDF
C-Plumbing- Part 2.pdf PDF
P03_CDR - Sole Source JA - Public Announcement System - 11-16-22.pdf PDF
C-Electrical- Part 4.pdf PDF
A-Architecture-Part 3.pdf PDF
A-ICRA.pdf PDF
C-Architecture- Part 5.pdf PDF
A-Fire Protection-Part 2.pdf PDF
C-Electrical- Part 10.pdf PDF
P03_CDR - Sole Source JA - Triplex Pump 11-16-22.pdf PDF
C-Life Safety.pdf PDF
A-Electrical-Part 1.pdf PDF
VHA Directive 1028_D_2020-02-24.pdf PDF
B-Electrical-Part 2.pdf PDF
B-Architecture-Part 4.pdf PDF
C-Electrical- Part 12.pdf PDF
A-Electrical-Part 3.pdf PDF
C-Electrical- Part 7.pdf PDF
C-Electrical- Part 8.pdf PDF
A-Civil.pdf PDF
A-Structural.pdf PDF
A-General.pdf PDF
QSE 36C10F24R50018.pdf PDF
Amendment 0001 - Missing and Replacement Documents.pdf PDF
B-Electrical-Part 1.pdf PDF
C-Fire Protection- Part 2.pdf PDF
C-Electrical- Part 11.pdf PDF
C-Telecom.pdf PDF
A-Plumbing-Part 2.pdf PDF
C-Architecture- Part 6.pdf PDF
B-Electrical-Part 3.pdf PDF
VAMC CD Refresh IFC Vol 1 Specifications REV 2_ 9-19-23 (Part 3).pdf PDF
C-Mechanical- Part 3.pdf PDF
Shutdown Request Form.pdf PDF
B-Architecture-Part 2.pdf PDF
P03_CD Refresh - Sole Source JA - Fire Alarm System - 11-16-22.pdf PDF
Show 40 more

Latest 50 of 281 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENSET #2

GEN-2

GENSET #3

GEN-3

PARALLELING SWITCHGEAR ROOM

PSR-1

BLDG. #5 MAIN ELECTRIC ROOM

MER-5

20.5

22.8 22.9

20.5

22.8

18.1 22.9

DD.8

EE

20 22 23

EX

EX

EX

EX

EX EX

EX

EX.

13 15

18 20 22 23 24 26

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

PARTIAL FIRST FLOOR PLAN - GENERATOR PLATFORM

F4

PLAN

NORTH

AutoCAD SHX Text

GENERATORS

AutoCAD SHX Text

MASTER

AutoCAD SHX Text

CONTROLS

AutoCAD SHX Text

(GMC)

AutoCAD SHX Text

GEN 1

AutoCAD SHX Text

GEN 2

AutoCAD SHX Text

GEN 3

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

SPACE FOR PANELS

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

FOR BATTERY RACK

AutoCAD SHX Text

DN

AutoCAD SHX Text D

AutoCAD SHX Text C.1

AutoCAD SHX Text C

AutoCAD SHX Text B.4

AutoCAD SHX Text B

AutoCAD SHX Text A.8

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2.8

AutoCAD SHX Text

AutoCAD SHX Text 3.8

AutoCAD SHX Text

AutoCAD SHX Text 3.5

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text 4"

AutoCAD SHX Text 3"

AutoCAD SHX Text 4"

AutoCAD SHX Text D

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 4"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text E

AutoCAD SHX Text 3"

AutoCAD SHX Text E

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER PLANT ENGINEER OFFICE

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

ENGINEER OFFICE

AutoCAD SHX Text

MATCHLINE, FOR CONTINUATION, SEE C-F111

AutoCAD SHX Text M1.3

AutoCAD SHX Text M1.4

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text 3"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 3"

AutoCAD SHX Text M1.5

AutoCAD SHX Text 3"

AutoCAD SHX Text D

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text D1

AutoCAD SHX Text D2

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 LOCATION OF EXISTING 3-INCH DRY PIPE VALVE SERVING EXISTING DRY-PIPE SPRINKLER SYSTEM FOR LOCATION OF EXISTING 3-INCH DRY PIPE VALVE SERVING EXISTING DRY-PIPE SPRINKLER SYSTEM FOR TRANSFORMER VAULT IN BUILDING 5. SHOWN FOR REFERENCE ONLY.

AutoCAD SHX Text 2 EXISTING 4-INCH STANDPIPE CONNECTION TO FIRE HOSE VALVE.EXISTING 4-INCH STANDPIPE CONNECTION TO FIRE HOSE VALVE.

AutoCAD SHX Text 3 PROVIDE PIPING EXPANSION JOINT FOR SEISMIC SEPARATION BETWEEN BUILDINGS. FITTINGS SHALL BE PROVIDE PIPING EXPANSION JOINT FOR SEISMIC SEPARATION BETWEEN BUILDINGS. FITTINGS SHALL BE WATERPROOF SEISMIC WALL-PENETRATION TYPE. EXTERIOR PIPING, FITTINGS, AND HANGERS EXPOSED TO OUTSIDE WEATHER SHALL BE PROTECTED FROM CORROSION IN ACCORDANCE WITH NFPA 13, SECTION CORROSION IN ACCORDANCE WITH NFPA 13, SECTION 16.4.2.

AutoCAD SHX Text 4 NEW 3-INCH DRY PIPE VALVE SERVING NEW DRY-PIPE SPRINKLER SYSTEM FOR SWITCHGEAR VAULT ON NEW 3-INCH DRY PIPE VALVE SERVING NEW DRY-PIPE SPRINKLER SYSTEM FOR SWITCHGEAR VAULT ON GENERATOR PLATFORM. SPRINKLER DRAIN TO BE PIPED ALONG RAISED SLAB AND TO SPILL TO THE NEAREST FLOOR DRAIN.

AutoCAD SHX Text 5 GENERATOR ENCLOSURES ARE NOT EQUIPPED WITH AUTOMATIC SPRINKLER PROTECTION. GENERATOR GENERATOR ENCLOSURES ARE NOT EQUIPPED WITH AUTOMATIC SPRINKLER PROTECTION. GENERATOR ENCLOSURES WILL BE PROTECTED WITH AUTOMATIC HEAT DETECTION MONITORED BY THE FIRE ALARM SYSTEM AS APPROVED IN PREVIOUS DESIGNS PER VA FP DESIGN MANUAL SECTION 7.4.E. SEE FIRE ALARM DRAWINGS FOR FURTHER DETAIL.

AutoCAD SHX Text 6 ALL NEW EXPOSED SPRINKLER PIPING TO BE PAINTED RED.ALL NEW EXPOSED SPRINKLER PIPING TO BE PAINTED RED.

AutoCAD SHX Text 7 EXISTING FLOOR DRAIN TO BE EQUIPPED TO RECEIVE SPRINKLER DRAIN DISCHARGE. PROVIDE HARD EXISTING FLOOR DRAIN TO BE EQUIPPED TO RECEIVE SPRINKLER DRAIN DISCHARGE. PROVIDE HARD PIPE FROM NEW DRY VALVE MAIN DRAIN TO THIS PIPE. ENSURE PIPING IS TUCKED NEXT TO EXISTING CEMENT PADS IN ROOM AND DOES NOT CREATE A TRIPPING HAZARD.

AutoCAD SHX Text 8 RUN SPRINKLER PIPE HIGH ABOVE NEW STAIRWELL ENCLOSURE. SPRINKLER PIPE TO ENTER SWITCHGEAR RUN SPRINKLER PIPE HIGH ABOVE NEW STAIRWELL ENCLOSURE. SPRINKLER PIPE TO ENTER SWITCHGEAR ROOM AT CEILING LEVEL. ADJUST PIPING ELEVATION IN BUILDING 4 CHILLER ROOM TO THE SAME ELEVATION AS THE CEILING LEVEL OF SWITCHGEAR ROOM.

AutoCAD SHX Text

1. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS. 2. PROVIDE NEW HEADS AND SPRINKLER PIPING WITHIN THE PARALLEL SWITCHGEAR PROVIDE NEW HEADS AND SPRINKLER PIPING WITHIN THE PARALLEL SWITCHGEAR ROOM. 3. RECONNECT TO EXISTING SPRINKLERS THAT CROSS BOUNDARY OF AREA OF RECONNECT TO EXISTING SPRINKLERS THAT CROSS BOUNDARY OF AREA OF RENOVATION. 4. PAINT ALL EXPOSED FIRE PROTECTION PIPING RED INCLUDING THREADED PIPE PAINT ALL EXPOSED FIRE PROTECTION PIPING RED INCLUDING THREADED PIPE HANGERS. 5. PROVIDE SPRINKLER GUARDS ON ALL UPRIGHT SPRINKLER HEADS WITHIN AREA PROVIDE SPRINKLER GUARDS ON ALL UPRIGHT SPRINKLER HEADS WITHIN AREA OF RENOVATION. 6. WHERE OBSTRUCTIONS TO SPRINKLER DISCHARGE EXIST, SPRINKLERS SHALL WHERE OBSTRUCTIONS TO SPRINKLER DISCHARGE EXIST, SPRINKLERS SHALL BE LOCATED WITH RESPECT TO THE OBSTRUCTIONS IN ACCORDANCE WITH NFPA 13. REVIEW ALL AREAS IN THE SCOPE OF WORK TO ENSURE ALL OBSTRUCTIONS ARE ACCOUNTED FOR. ADD ADDITIONAL SPRINKLER HEADS WHERE REQUIRED.

AutoCAD SHX Text 9 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW BUILDING 4/5. SEE SHEET C-FX102 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW BUILDING 4/5. SEE SHEET C-FX102 FOR CONTINUATION.

AutoCAD SHX Text 10 DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW PARALLELING SWITCHGEAR ROOM. SEE DRY PIPE SPRINKLER LINE DOWN TO PROTECT CONDUIT BELOW PARALLELING SWITCHGEAR ROOM. SEE SHEET C-FX102 FOR CONTINUATION

AutoCAD SHX Text

KEY NOTES

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FX112

AutoCAD SHX Text

NEW WORK

AutoCAD SHX Text

PARTIAL FIRST FLOOR PLAN -

AutoCAD SHX Text

BUILDINGS 1 AND 6 -

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 16'

NORMAL POWER ROOM

EMERGENCY POWER ROOM

20 22 23

AA

BB

DD

B

C

M FIRE PUMP

A

JP

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

1/2" = 1'-0"C5 ENLARGED FLOOR PLAN - SPRINKLER PUMP ROOM G125W

NTSF4 FIRE PUMP ASSEMBLY RISER DIAGRAM - EXISTING

PLAN

NORTH

1/2" = 1'-0"E1 ENLARGED FLOOR PLAN - EMERGENCY AND NORMAL POWER ROOMS 101 AND 102

PLAN

NORTH

AutoCAD SHX Text

FIRE PUMP

AutoCAD SHX Text G126W

AutoCAD SHX Text G125W

AutoCAD SHX Text V1

AutoCAD SHX Text

FPS

AutoCAD SHX Text

FPD

AutoCAD SHX Text V2

AutoCAD SHX Text M1

AutoCAD SHX Text

SRC

AutoCAD SHX Text V0

AutoCAD SHX Text 6"

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text 4"

AutoCAD SHX Text A

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text 6"

AutoCAD SHX Text

FP

AutoCAD SHX Text

JP

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

EXIST. MECH'L ROOM

AutoCAD SHX Text

EXIST. MECH'L ROOM

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text X

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text N

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text 3"

AutoCAD SHX Text S2.1

AutoCAD SHX Text S2.2

AutoCAD SHX Text S2.3

AutoCAD SHX Text S2.4

AutoCAD SHX Text S2.5

AutoCAD SHX Text S2.6

AutoCAD SHX Text S2.7

AutoCAD SHX Text S2.8

AutoCAD SHX Text S2.9

AutoCAD SHX Text S2.10

AutoCAD SHX Text S2.11

AutoCAD SHX Text S2.12

AutoCAD SHX Text S2.13

AutoCAD SHX Text S2.14

AutoCAD SHX Text S2.16

AutoCAD SHX Text S2.17

AutoCAD SHX Text M2.6

AutoCAD SHX Text M2.5

AutoCAD SHX Text M2.4

AutoCAD SHX Text L2.1

AutoCAD SHX Text M2.3

AutoCAD SHX Text M2.2

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text 1 "12"

AutoCAD SHX Text L2.2

AutoCAD SHX Text L2.3

AutoCAD SHX Text L2.4

AutoCAD SHX Text L2.5

AutoCAD SHX Text L2.6

AutoCAD SHX Text L2.7

AutoCAD SHX Text L2.8

AutoCAD SHX Text L2.9

AutoCAD SHX Text L2.10

AutoCAD SHX Text L2.11

AutoCAD SHX Text L2.12

AutoCAD SHX Text L2.13

AutoCAD SHX Text L2.14

AutoCAD SHX Text L2.15

AutoCAD SHX Text L2.17

AutoCAD SHX Text L2.16

AutoCAD SHX Text S2.15

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text REMOTE AREA #C2 HAZARD: ORDINARY HAZARD GROUP 1 DEMAND AREA: 1,500 SQ FT (ACTUAL = 1,565 SQ FT) DENSITY: 0.15 GPM/SQ FT K-FACTOR: 5.6 SYSTEM DEMAND: 433.3 GPM AT 123.96 PSI AVAILABLE FLOW/PRESSURE: 433.3 GPM AT 155.00 PSI

AutoCAD SHX Text

%%UREMOTE AREA HYDRAULIC CALCULATIONS

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

1. THIS DRAWING IS INTENDED FOR USE AS A REFERENCE ONLY. NO DEMOLITION OR NEW WORK IS THIS DRAWING IS INTENDED FOR USE AS A REFERENCE ONLY. NO DEMOLITION OR NEW WORK IS REQUIRED FOR THE EXISTING FIRE PUMP ASSEMBLY, SYSTEM PIPING, AND CONTROL PANELS.

AutoCAD SHX Text

RISER DIAGRAM NOTES

AutoCAD SHX Text

TO BUILDING 6 FIRE SPRINKLER SYSTEM

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 4"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 4"

AutoCAD SHX Text 4"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 4"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

TO BUILDING 1 FIRE SPRINKLER SYSTEM

AutoCAD SHX Text

TO FIRE DEPARTMENT CONNECTION

AutoCAD SHX Text

EXISTING JOCKEY PUMP CONTROLLER

AutoCAD SHX Text

EXISTING FIRE PUMP CONTROLLER

AutoCAD SHX Text

EXISTING 500 GPM AT 120 PSI FIRE PUMP ON SKID

AutoCAD SHX Text

EXISTING FIRE PUMP TEST HEADER

AutoCAD SHX Text 6"

AutoCAD SHX Text

FROM CITY WATER MAIN

AutoCAD SHX Text E

AutoCAD SHX Text

EXISTING JOCKEY PUMP ON SKID

AutoCAD SHX Text

EXISTING CONCRETE PUMP SKID

AutoCAD SHX Text

EXISTING 4"X6" PIPE INCREASER WITH SIGHT GLASS

AutoCAD SHX Text V1

AutoCAD SHX Text

SRC

AutoCAD SHX Text

FPS

AutoCAD SHX Text

FPD

AutoCAD SHX Text V2

AutoCAD SHX Text M1

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text V0

AutoCAD SHX Text

1. REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FX001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

AutoCAD SHX Text 1 EXISTING 6-INCH INCOMING FIRE SERVICE MAIN.EXISTING 6-INCH INCOMING FIRE SERVICE MAIN.

AutoCAD SHX Text 2 EXISTING 500 GPM FIRE PUMP AND EXISTING JOCKEY PUMP ON CONCRETE SKID.EXISTING 500 GPM FIRE PUMP AND EXISTING JOCKEY PUMP ON CONCRETE SKID.

AutoCAD SHX Text

3 EXISTING FIRE PUMP CONTROLLER.EXISTING FIRE PUMP CONTROLLER.

AutoCAD SHX Text

4 EXISTING JOCKEY PUMP CONTROLLEREXISTING JOCKEY PUMP CONTROLLER

AutoCAD SHX Text 5 EXISTING 6-INCH SUCTION AND 6-INCH DISCHARGE PIPING AND ASSOCIATED EXISTING 6-INCH SUCTION AND 6-INCH DISCHARGE PIPING AND ASSOCIATED VALVES. REFER TO FIRE PUMP RISER DIAGRAM FOR FURTHER DETAIL.

AutoCAD SHX Text

KEY NOTES

AutoCAD SHX Text

AutoCAD SHX Text

GENERAL NOTES

AutoCAD SHX Text 6 EXISTING 4-INCH FIRE PROTECTION PIPING TO FIRE DEPARTMENT CONNECTION.EXISTING 4-INCH FIRE PROTECTION PIPING TO FIRE DEPARTMENT CONNECTION.

AutoCAD SHX Text 7 SOURCE FOR HYDRAULIC CALCULATIONS TAKEN FROM THE TEST HEADER. SOURCE FOR HYDRAULIC CALCULATIONS TAKEN FROM THE TEST HEADER. INFORMATION OF THE FIRE PUMP TEST RESULTS DATED MAY 19, 2020. STATIC PRESSURE: 45 PSI 45 PSI RESIDUAL PRESSURE: 35 PSI 35 PSI AVAILABLE FLOW: 796 GPM796 GPM

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FX401

AutoCAD SHX Text

ENLARGED PLANS

BUILDINGS 1 AND 6 -

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

NTSF8 RISER MOUNTED AIR COMPRESSOR

NTSD8 DRY SYSTEM AUXILIARY DRAIN

NTSD4 SPRINKLER HEAD DROP DETAIL

NTSB4 UPRIGHT HEAD DETAIL

NTSF4 DRY VALVE SYSTEM COMPONENTS

NTSF1 SPRINKLER HEAD PROTECTING CONDUIT

D1 ZONE CONTROL VALVE COMPONENTS

AutoCAD SHX Text

PRESSURE SWITCH

AutoCAD SHX Text

RISER MOUNTING KIT

AutoCAD SHX Text

SYSTEM RISER

AutoCAD SHX Text

AIR INTAKE FILTER(S)

AutoCAD SHX Text

GENERAL RISER MOUNTED AIR COMPRESSOR

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

RELIEF VALVE

AutoCAD SHX Text

TO VALVE AIR TRIM

AutoCAD SHX Text

CONNECT TO AIR MAINTENANCE DEVICE

AutoCAD SHX Text

1-INCH GLOBE VALVE

AutoCAD SHX Text

2 X 1 REDUCING COUPLING

AutoCAD SHX Text

2-INCH X 1-FOOT PIPE NIPPLE

AutoCAD SHX Text

2 X 1 REDUCING COUPLING

AutoCAD SHX Text

1-INCH GLOBE VALVE

AutoCAD SHX Text

1-INCH PLUG

AutoCAD SHX Text

1-INCH PIPE FROM SYSTEM

AutoCAD SHX Text

PROVIDE SUPPORT AS REQUIRED

AutoCAD SHX Text

1-INCH BLACK STEEL SCHEDULE 40 PIPING (TYP.)

AutoCAD SHX Text

NEW SPRINKLER MAIN

AutoCAD SHX Text

1 INCH PIPE REDUCING COUPLING

AutoCAD SHX Text

SUSPENDED CEILING

AutoCAD SHX Text

PROVIDE LENGTH TO SUIT

AutoCAD SHX Text

PROVIDE NEW (QR) FM/UL SEMI-RECESSED PENDENT HEAD, CENTER OF TILE

AutoCAD SHX Text NOTES: 1. ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH ADJUST SPRINKLER DROPS AS NECESSARY TO CLEAR OBSTRUCTIONS SUCH AS CEILING "T" BAR SUSPENSION SYSTEM. LIGHT FIXTURES, ETC. PROVIDE A PIPE HANGER IF THE HORIZONTAL OFFSET LENGTH EXCEEDS 24" 2. ALL NEW PENDENT HEADS SHALL BE FM APPROVED, SEMI-RECESSED, ALL NEW PENDENT HEADS SHALL BE FM APPROVED, SEMI-RECESSED, QUICK RESPONSE TYPE. 3. ALL NEW HEADS SHALL BE CENTER OF TILE.ALL NEW HEADS SHALL BE CENTER OF TILE.

AutoCAD SHX Text 12"

AutoCAD SHX Text

NON COMBUSTIBLE METAL ROOF DECKING

AutoCAD SHX Text

BRANCHLINE WITH SIZE AS SHOWN ON PLAN

AutoCAD SHX Text

1-INCH SPRIG UP

AutoCAD SHX Text

DEFLECTOR DISTANCES TO CONFORM WITH REQUIREMENTS OF NFPA 13 SECTION 10.2.7.2.

AutoCAD SHX Text

UPRIGHT HEAD WITH GUARD

AutoCAD SHX Text

STRUCTURAL WEB JOIST/ BEAM WITH WRAPPED FIREPROOFING

AutoCAD SHX Text

AS NOTED ON SITE

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

PIPE DISCHARGE TO FLOOR DRAIN

AutoCAD SHX Text

PROVIDE SUPPORT AS REQUIRED

AutoCAD SHX Text

DRAIN CUP

AutoCAD SHX Text

FROM SPRINKLER MAIN

AutoCAD SHX Text

INDICATING BUTTERFLY VALVE WITH SUPERVISORY SWITCH

AutoCAD SHX Text

ALARM PRESSURE SWITCH

AutoCAD SHX Text

ACCELERATOR

AutoCAD SHX Text

AIR PRESSURE SUPERVISORY SWITCH

AutoCAD SHX Text

AIR PRESSURE MAINTENANCE DEVICE

AutoCAD SHX Text

PRESSURE GAUGE

AutoCAD SHX Text

TO SPRINKLERS

AutoCAD SHX Text

AIR COMPRESSOR

AutoCAD SHX Text

DRY VALVE

AutoCAD SHX Text

LINES OF ELECTRICAL CONDUITS BEYOND. SEE ELECTRICAL DRAWINGS

AutoCAD SHX Text

3-INCH MAIN LINE RUNNING PARALLEL TO CONDUIT

AutoCAD SHX Text

UPRIGHT SPRINKLER HEAD WITH CAGE OVER CONDUIT

AutoCAD SHX Text

BUTTERFLY VALVE WITH TAMPER SWITCH

AutoCAD SHX Text

CHECK VALVE

AutoCAD SHX Text

FLOW SWITCH

AutoCAD SHX Text

TO SPRINKLER SYSTEM

AutoCAD SHX Text

TEST & DRAIN ASSEMBLY

AutoCAD SHX Text

PIPING TO DRAIN

AutoCAD SHX Text

PRESSURE RELIEF VALVE

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FX501

AutoCAD SHX Text

FIRE SUPPRESSION

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

BLDG 6

MAIN ENTRANCE

Q

R

T

R

S

Q

N

L

11 12

13 15

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

PARTIAL FIRST FLOOR PLAN

D3

PLAN

NORTH

AutoCAD SHX Text

ELEC 1052C-EL

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

DUCT SHAFT

AutoCAD SHX Text

MEN'S TOILET

AutoCAD SHX Text

STAFF FEM.

AutoCAD SHX Text

MAIN LOBBY

AutoCAD SHX Text 1003W

AutoCAD SHX Text

ENTRY

AutoCAD SHX Text 1004W

AutoCAD SHX Text 133.14

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1058S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1059S

AutoCAD SHX Text

COMMNUNICATION

AutoCAD SHX Text 1060S

AutoCAD SHX Text

SECRETARY

AutoCAD SHX Text

1060AS

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1057S

AutoCAD SHX Text

PLANTER

AutoCAD SHX Text

ELIGIBILITY INTERVIEW #1

AutoCAD SHX Text 1501A

AutoCAD SHX Text

ELECTRIC RM

AutoCAD SHX Text

1052C-EL

AutoCAD SHX Text

ELECTRIC RM

AutoCAD SHX Text

1003W-EL

AutoCAD SHX Text

DRESSING ROOM

AutoCAD SHX Text 1067S

AutoCAD SHX Text

FIRE PANEL ROOM

AutoCAD SHX Text 1000W

AutoCAD SHX Text 1001C

AutoCAD SHX Text

MATCHLINE, FOR CONTINUATION, SEE C-FA111

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text

FACP

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.' REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.' 2. THERE IS NO NEW WORK ON THIS SHEET. SHEET PROVIDED FOR REFERENCE ONLY.THERE IS NO NEW WORK ON THIS SHEET. SHEET PROVIDED FOR REFERENCE ONLY.

AutoCAD SHX Text 1 LOCATION OF EXISTING FIRE ALARM PANELS AND EQUIPMENT SHOWN FOR REFERENCE ONLY. LOCATION OF EXISTING FIRE ALARM PANELS AND EQUIPMENT SHOWN FOR REFERENCE ONLY. 2 EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING CONSTRUCTION. MAINTAIN FIRE ALARM CIRCUIT INTEGRITY OF EXISTING FIRE ALARM CIRCUIT.

AutoCAD SHX Text

%%UKEYNOTES

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FA110

AutoCAD SHX Text

NEW WORK

AutoCAD SHX Text

PARTIAL FIRST FLOOR PLAN -

AutoCAD SHX Text

BUILDINGS 1 AND 6 -

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

Z.8

AA.2

NORMAL POWER ROOM

1115AC-EL

EMERGENCY POWER ROOM

ELEC

1056S-EL

ELEC

1064S-EL

ELEC

DD.5

20.5

22.8 22.9

22.8 22.9

18.2 20.5 22.8

18.1

22.9

22.8

18.1 22.9

18.4

DD.8

BB.5

AA.5AA.5

EE

BB

AA

22 23

DD

HH

10 11

W

X

Z

4 5 7 92 31

EX

EX

EX

EX

EX

EX

EX

DD

EX

X

V

W

U

Y

Z

AA

BB

DD

EE

11 12

13 15

9754321

18 20 22 23

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

PARTIAL FIRST FLOOR PLAN

F1

PLAN

NORTH

AutoCAD SHX Text

ELEC 1056S-EL

AutoCAD SHX Text

ELEC 1115AC-EL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

STAIRS #3

AutoCAD SHX Text 1071S

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

SERVICE ELEV.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

DUCT SHAFT

AutoCAD SHX Text

EL. CAB.

AutoCAD SHX Text 1073S

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text 1078S

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text 1077S

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text 1076S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1075S

AutoCAD SHX Text

CHIEF OF VOLUNTEER

AutoCAD SHX Text 1074S

AutoCAD SHX Text

LOUNGE

AutoCAD SHX Text 1072S

AutoCAD SHX Text

BOARD OF ED.

AutoCAD SHX Text 1071S

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1070S

AutoCAD SHX Text

INTERVIEW

AutoCAD SHX Text 1080S

AutoCAD SHX Text

P16 ELEV

AutoCAD SHX Text

CONTROL

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 1082S

AutoCAD SHX Text

W. TOILET

AutoCAD SHX Text 1083S

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text 1085S

AutoCAD SHX Text

WAITING

AutoCAD SHX Text 1079S

AutoCAD SHX Text

VACANT

AutoCAD SHX Text

1089AS

AutoCAD SHX Text

EL. CAB.

AutoCAD SHX Text 1073A-S

AutoCAD SHX Text

SECONDARY MANIFOLD RM

AutoCAD SHX Text 1091S

AutoCAD SHX Text

PATIENT FUNDS

AutoCAD SHX Text 1114C

AutoCAD SHX Text

MEN'S TOILET

AutoCAD SHX Text 1052C

AutoCAD SHX Text

STAFF FEM.

AutoCAD SHX Text 1038C

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 1095S

AutoCAD SHX Text

MED / AIR RM

AutoCAD SHX Text 1092S

AutoCAD SHX Text

BARBER SHOP

AutoCAD SHX Text 1090S

AutoCAD SHX Text

FA ATS

AutoCAD SHX Text 1093S

AutoCAD SHX Text

RETAIL STORE AREA

AutoCAD SHX Text 1064S

AutoCAD SHX Text

ELEC. CLOS.

AutoCAD SHX Text 1087S

AutoCAD SHX Text

QA OFFICE

AutoCAD SHX Text 1086S

AutoCAD SHX Text

SVC. ORGANIZATION

AutoCAD SHX Text 1089S

AutoCAD SHX Text

SECRETARY

AutoCAD SHX Text

1060AS

AutoCAD SHX Text

RECEPTION

AutoCAD SHX Text

1053AS

AutoCAD SHX Text 1057S

AutoCAD SHX Text

TRAINING RM.

AutoCAD SHX Text 1056S

AutoCAD SHX Text

WOMEN'S

AutoCAD SHX Text 1055S

AutoCAD SHX Text

MEN'S LOCKER

AutoCAD SHX Text 1054S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 1053S

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text 1095C

AutoCAD SHX Text

CONSULTATION

AutoCAD SHX Text

1125BN

AutoCAD SHX Text

CONSULTATION

AutoCAD SHX Text

1125AN

AutoCAD SHX Text

CLOSET

AutoCAD SHX Text

1124AN

AutoCAD SHX Text

OUTPATIENT PHARM. SUPR.

AutoCAD SHX Text 1122N

AutoCAD SHX Text

AGENT CASHIER

AutoCAD SHX Text 1161N

AutoCAD SHX Text

SUPPORT SVC.

AutoCAD SHX Text 1093C

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 1097C

AutoCAD SHX Text

POLICE OFFICE

AutoCAD SHX Text

1106AC

AutoCAD SHX Text

SUB CORRIDOR

AutoCAD SHX Text 1101C

AutoCAD SHX Text

MEDICAL DATA

AutoCAD SHX Text 1107C

AutoCAD SHX Text

SUPPORT SERV.

AutoCAD SHX Text

1110CC

AutoCAD SHX Text

MAS. SUP.

AutoCAD SHX Text

1110BC

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text

1115BC

AutoCAD SHX Text

PHARM. OFFICE

AutoCAD SHX Text

1121BN

AutoCAD SHX Text

GAS METERS

AutoCAD SHX Text

1107AC

AutoCAD SHX Text

POLICE OFFICE

AutoCAD SHX Text 1106C

AutoCAD SHX Text

POLICE OFFICE

AutoCAD SHX Text

1106BC

AutoCAD SHX Text

UP

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

UP

AutoCAD SHX Text

VESTIBULE

AutoCAD SHX Text 1107 E

AutoCAD SHX Text

STAIR

AutoCAD SHX Text 1-1

AutoCAD SHX Text

MEDICAL ADMINISTRATION RECORDS

AutoCAD SHX Text 1101C

AutoCAD SHX Text

MATERIAL DIST. ROOM

AutoCAD SHX Text

1101AC

AutoCAD SHX Text

MECHANICAL RM.

AutoCAD SHX Text

1099AC

AutoCAD SHX Text

VACANT

AutoCAD SHX Text

1110AC

AutoCAD SHX Text

LOCKER RM.

AutoCAD SHX Text

1117AC

AutoCAD SHX Text

LOCKER RM.

AutoCAD SHX Text

1117BC

AutoCAD SHX Text

CHIEF HEALTH INFO.

AutoCAD SHX Text

1117CC

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text 1111C

AutoCAD SHX Text

MALE TOILET

AutoCAD SHX Text

1113AC

AutoCAD SHX Text

FEMALE LOCKERS

AutoCAD SHX Text

1119AC

AutoCAD SHX Text

MALE LOCKERS

AutoCAD SHX Text 1113C

AutoCAD SHX Text

EXIST. MECH'L ROOM

AutoCAD SHX Text

EXIST. MECH'L ROOM

AutoCAD SHX Text

EXIST. CORRIDOR

AutoCAD SHX Text

EXIST. CORRIDOR

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text

RD

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text

ELECTRIC RM

AutoCAD SHX Text

1107C-EL

AutoCAD SHX Text

MEDICAL INFORMATION

AutoCAD SHX Text

1115AC

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text

HVAC

AutoCAD SHX Text

AutoCAD SHX Text

WAITING

AutoCAD SHX Text

1115CC

AutoCAD SHX Text

OFFICE

AutoCAD SHX Text

1115DC

AutoCAD SHX Text

SERVICE ELEV.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

SERVICE ELEV.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

SERVICE ELEV.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

SERVICE ELEV.

AutoCAD SHX Text

SHAFT

AutoCAD SHX Text

AutoCAD SHX Text

ELEV. SHAFT

AutoCAD SHX Text

MATCHLINE, FOR CONTINUATION, SEE C-FA112

AutoCAD SHX Text N

AutoCAD SHX Text 110cd

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text 15cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text 75cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text 75cd

AutoCAD SHX Text N

AutoCAD SHX Text 75cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text

MATCHLINE, FOR CONTINUATION, SEE C-FA110

AutoCAD SHX Text P

AutoCAD SHX Text 15cd

AutoCAD SHX Text 15cd

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text 75cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text 75cd

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text

RIL-TS

AutoCAD SHX Text

RM

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text N

AutoCAD SHX Text

NAC

AutoCAD SHX Text E

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text 60cd

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

AutoCAD SHX Text 1 EXISTING MONITOR MODULES FOR SPRINKLER SYSTEM SUPERVISION SHOWN FOR REFERENCE ONLY. EXISTING MONITOR MODULES FOR SPRINKLER SYSTEM SUPERVISION SHOWN FOR REFERENCE ONLY. 2 PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO NEW NAC AND SPEAKER CIRCUIT IN PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO NEW NAC AND SPEAKER CIRCUIT IN NEW PANELS. SEE KEYNOTE 10. 3 PROVIDE NEW STROBE. CONNECT TO CLOSEST NAC WITH SUFFICIENT SPARE POWER SUPPLY CAPACITY. PROVIDE NEW STROBE. CONNECT TO CLOSEST NAC WITH SUFFICIENT SPARE POWER SUPPLY CAPACITY. 4 EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING EXISTING FIRE ALARM DEVICE TO REMAIN. DEVICE TO BE PROTECTED AND REMAIN ACTIVE DURING CONSTRUCTION. MAINTAIN FIRE ALARM CIRCUIT INTEGRITY OF EXISTING FIRE ALARM CIRCUIT. 5 REINSTALL STROBE. CONNECT TO SAME NAC AS REMOVED FROM PRIOR TO DEMOLITION. REINSTALL STROBE. CONNECT TO SAME NAC AS REMOVED FROM PRIOR TO DEMOLITION. 6 PROVIDE NEW MONITOR MODULES FOR NEW ZONE CONTROL VALVE. CONNECT ACCESSIBLE DEVICES TO PROVIDE NEW MONITOR MODULES FOR NEW ZONE CONTROL VALVE. CONNECT ACCESSIBLE DEVICES TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. 7 DUCT DETECTOR PROVIDED ON SUPPLY DUCTWORK FOR RTU-2. CONNECT ADDRESSABLE DEVICE TO DUCT DETECTOR PROVIDED ON SUPPLY DUCTWORK FOR RTU-2. CONNECT ADDRESSABLE DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. COORDINATE AUTOMATIC CONTROL REQUIREMENTS WITH THE MECHANICAL SYSTEM. REFER TO MECHANICAL DRAWINGS FOR FURTHER DETAILS. 8 PROVIDE NEW RELAY MODULE IN CEILING FOR RTU-2 FAN SHUTDOWN AND BMS SIGNAL ON ROOF. MODULE PROVIDE NEW RELAY MODULE IN CEILING FOR RTU-2 FAN SHUTDOWN AND BMS SIGNAL ON ROOF. MODULE SIGNALS SHALL INTERFACE WITH BUILDING CONTROLS. REFER TO MECHANICAL DRAWINGS FOR FURTHER DETAIL. 9 PROVIDE REMOTE INDICATING LAMP AND TEST KEY SWITCH ON WALL. DEVICE SHALL BE LOCATED 7 FEET PROVIDE REMOTE INDICATING LAMP AND TEST KEY SWITCH ON WALL. DEVICE SHALL BE LOCATED 7 FEET ABOVE FINISHED FLOOR TO FACILITATE TESTING OF DUCT SMOKE DETECTOR. 10 PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO ELECTRICAL ROOM FIRE ALARM SYSTEM PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO ELECTRICAL ROOM FIRE ALARM SYSTEM DEVICES. CONNECT FATC TO MAIN HOSPITAL FACP. PROVIDE BATTERY BACKUP FOR SPEAKER/STROBE CIRCUITS PER NFPA 72 WITH ENOUGH CAPACITY REQUIRED BY SPECIFICATION 28 31 00. 11 PROVIDE NEW MANUAL PULL STATION. CONNECT TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. PROVIDE NEW MANUAL PULL STATION. CONNECT TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS. 12 ADD MONITOR MODULE TO MONITOR EXISTING ISOLATION VALVE. CONNECT DEVICE TO CLOSEST SLC. VERIFY ADD MONITOR MODULE TO MONITOR EXISTING ISOLATION VALVE. CONNECT DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS.

AutoCAD SHX Text

%%UKEYNOTES

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FA111

AutoCAD SHX Text

NEW WORK

AutoCAD SHX Text

PARTIAL FIRST FLOOR PLAN -

AutoCAD SHX Text

BUILDINGS 1 AND 6 -

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

GENSET #2

GEN-2

GENSET #3

GEN-3

PARALLELING SWITCHGEAR ROOM

PSR-1

BLDG. #5 MAIN ELECTRIC ROOM

MER-5

20.5

22.8 22.9

20.5

22.8

18.1 22.9

DD.8

DD.8

EE

20 22 23

302826

EX

EX

EX

EX

EX EX

EX

EX.

EE

EX

13 15

18 20 22 23 24 26

28 30

PARTIAL FIRST FLOOR PLAN - GENERATOR PLATFORM

F4

PLAN

NORTH

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

AutoCAD SHX Text

GENERATORS

AutoCAD SHX Text

MASTER

AutoCAD SHX Text

CONTROLS

AutoCAD SHX Text

(GMC)

AutoCAD SHX Text

GEN 1

AutoCAD SHX Text

GEN 2

AutoCAD SHX Text

GEN 3

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

FB

AutoCAD SHX Text

SPACE FOR PANELS

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

DN

AutoCAD SHX Text

SPACE

AutoCAD SHX Text

FOR BATTERY RACK

AutoCAD SHX Text

DN

AutoCAD SHX Text D

AutoCAD SHX Text C.1

AutoCAD SHX Text C

AutoCAD SHX Text B.4

AutoCAD SHX Text B

AutoCAD SHX Text A.8

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 2.8

AutoCAD SHX Text

AutoCAD SHX Text 3.8

AutoCAD SHX Text

AutoCAD SHX Text 3.5

AutoCAD SHX Text

AutoCAD SHX Text

MATCHLINE, FOR CONTINUATION, SEE C-FA111

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text 30cd

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

N,WP

AutoCAD SHX Text 75cd

AutoCAD SHX Text N

AutoCAD SHX Text 75cd

AutoCAD SHX Text N

AutoCAD SHX Text 75cd

AutoCAD SHX Text

FATC

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text P

AutoCAD SHX Text N

AutoCAD SHX Text N

AutoCAD SHX Text

MM

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EXIST. MECH'L ROOM

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text

CHILLER

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text X

AutoCAD SHX Text

CHILLER PLANT ENGINEER OFFICE

AutoCAD SHX Text

CORRIDOR

AutoCAD SHX Text

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

ENGINEER OFFICE

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text

MM

AutoCAD SHX Text E

AutoCAD SHX Text

AutoCAD SHX Text

1. REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.REFER TO C-FA001 FOR GENERAL NOTES, SYMBOLS AND ABBREVIATIONS.

AutoCAD SHX Text 1 EXISTING MONITOR MODULES FOR SUPERVISION OF EXISTING DRY PIPE VALVE ASSEMBLY SERVING EXISTING MONITOR MODULES FOR SUPERVISION OF EXISTING DRY PIPE VALVE ASSEMBLY SERVING TRANSFORMER VAULT WITHIN BUIKLDING 5. REFER TO FIRE PROTECTION DRAWINGS FOR FURTHER DETAIL. 2 EXISTING SPARE MONITOR MODULES SHOWN FOR REFERENCE ONLY. EXISTING SPARE MONITOR MODULES SHOWN FOR REFERENCE ONLY. 3 NEW MONITOR MODULES FOR SUPERVISION OF NEW DRY PIPE VALVE AND MONITORING ABNORMAL NEW MONITOR MODULES FOR SUPERVISION OF NEW DRY PIPE VALVE AND MONITORING ABNORMAL AIR PRESSURE SERVING SWITCHGEAR VAULT ON GENERATOR PLATFORM AND BELOW BUILDINGS 4/5. CONNECT DEVICES TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. REFER TO FIRE PROTECTION DRAWINGS FOR FURTHER DETAIL. 4 TEMPORARY MANUAL PULL STATION SERVING INTERIM EXIT STAIRWAY. CONNECT ADDRESSABLE TEMPORARY MANUAL PULL STATION SERVING INTERIM EXIT STAIRWAY. CONNECT ADDRESSABLE DEVICE TO CLOSEST SLC. VERIFY SUFFICIENT ADDRESS SPARE CAPACITY AT PANEL. MANUAL PULL STATION TO BE REMOVED WHEN INTERIM EXIT STAIRWAY IS NO LONGER IN SERVICE AND REMOVED. 5 PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO GENERATOR PLATFORM FIRE ALARM PROVIDE NEW FIRE ALARM TERMINAL CABINET DEDICATED TO GENERATOR PLATFORM FIRE ALARM SYSTEM DEVICES. CONNECT FATC TO MAIN HOSPITAL FACP. PROVIDE BATTERY BACKUP FOR SPEAKER/STROBE CIRCUITS PER NFPA 72 WITH ENOUGH CAPACITY REQUIRED BY SPECIFICATION 28 31 00. 6 PROVIDE NEW HEAT DETECTOR OF FIXED TEMPERATURE TYPE WITH EXTRA HIGH TEMPERATURE PROVIDE NEW HEAT DETECTOR OF FIXED TEMPERATURE TYPE WITH EXTRA HIGH TEMPERATURE (325 DEG. F) RATING AS ALLOWED IN VA DESIGN MANUAL SECTION 7.4.E. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PLATFORM SLC. 7 PROVIDE NEW WEATHERPROOF SPEAKER/STROBE COMBINATION DEVICE UNDER CANOPY. CONNECT PROVIDE NEW WEATHERPROOF SPEAKER/STROBE COMBINATION DEVICE UNDER CANOPY. CONNECT TO GENERATOR PLATFORM NAC AND SPEAKER CIRCUITS. 8 PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO GENERATOR PLATFORM NAC PROVIDE NEW SPEAKER/STROBE COMBINATION DEVICE. CONNECT TO GENERATOR PLATFORM NAC AND SPEAKER CIRCUITS. 9 PROVIDE NEW MANUAL PULL STATION. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PROVIDE NEW MANUAL PULL STATION. CONNECT ADDRESSABLE DEVICE TO DEDICATED GENERATOR PLATFORM SLC.

AutoCAD SHX Text

%%UKEYNOTES

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FA112

AutoCAD SHX Text

NEW WORK

AutoCAD SHX Text

PARTIAL FIRST FLOOR PLAN -

AutoCAD SHX Text

BUILDINGS 1 AND 6 -

AutoCAD SHX Text

SCALE: 1/8" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 4'

AutoCAD SHX Text

AutoCAD SHX Text 16'

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

BLDG 6

ADDRESSABLE SMOKE

DETECTOR DEVICE

CEILING OR

DECKING

STANDARD JUNCTION BOX

(RECESSED)

CEILING OR

DECKING

STANDARD JUNCTION BOX

(SURFACE MOUNTED)

ADDRESSABLE SMOKE

DETECTOR DEVICE

STANDARD MOUNTING

BOX

MANUAL PULL STATION

BACKPLATE

LOCKING SCREW

MANUAL PULL STATION

HOUSING

PUSH

WIRE IN CONDUIT

STANDARD JUNCTION BOX

(RECESSED)

SEE ARCH. PLANS WALL OR

STRUCTURE SCHEDULE

WALL MOUNTED STROBE OR

SPEAKER/STROBE

FIRE ALARM SYSTEM INPUT/OUTPUT MATRIX

SYSTEM INPUTS SYSTEM OUTPUTS

X X X X X

X X X X X

X X X X X

X X X X X

X X X X X

X

X

X

X

X

WATERFLOW SWITCH

OS&Y VALVE WITH

TAMPER SWITCH

NOTE:

ADJUST WATERFLOW DEVICE (VANE TYPE)

TO SEND SIGNAL WITHIN 45 SECONDS OF

OPENING INSPECTOR TEST CONNECTION.

FIRE ALARM

WIRE/CONDUIT

WATERTIGHT

JUNCTION BOX

WATERTIGHT FIRE

ALARM CONDUIT

WATERTIGHT

JUNCTION BOX

WATERTIGHT FIRE

ALARM CONDUIT

SWITCHPLATE (BLANK)

INTELLIGENT

INTERFACE MODULE

4-INCH SQUARE X 3

1/2-INCH DEEP

ELECTRICAL JUNCTION

BOX

NOTE:

MOUNT INTELLIGENT INTERFACE MODULE

CLOSE TO ITS ASSOCIATED MONITORING

DEVICE OR CONTROL DEVICE (I.E. FIRE

SPRINKLER FLOW SWITCH, HVAC SHUTDOWN

AND DOOR HOLDER OPERATION) AT AN

ACCESSIBLE LOCATION

DUCTWORK

DUCT SMOKE DETECTOR

SAMPLING TUBE

REMOTE LIGHT/

SWITCH FOR DUCT

MOUNTED SMOKE

DETECTOR

NOTE:

1. MOUNT DETECTOR IN ACCORDANCE WITH

MANUFACTURERS RECOMMENDATIONS.

2. COORDINATE EXACT MOUNTING LOCATIONS OF THE

DUCT DETECTOR IN FIELD.

3. PROVIDE ALL INTELLIGENT DUCT SMOKE DETECTORS

WITH AN APPROPRIATELY SIZED DUCT SAMPLING TUBE.

ADDRESSABLE DUCT

MOUNTED SMOKE

DETECTOR

FIRE ALARM

WIRE/CONDUIT

TYPICAL JUNCTION BOX

TO OTHER FIRE ALARM DEVICES

DUCT SMOKE DETECTOR

EXHAUST TUBE

TYPICAL SURFACE MOUNTED SMOKE DETECTOR

NTS

B5

TYPICAL CEILING MOUNTED SMOKE DETECTOR

TYPICAL MANUAL PULL STATION

NTS

D5

TYPICAL WALL MOUNTED SPEAKER/STROBE

NTS

D7

FIRE ALARM OPERATION MATRIX

NTS

D1

TYPICAL DUCT DETECTOR DETAIL

NTS

F8

TYPICAL INTELLIGENT INTERFACE MODULE

NTS

F5

TYPICAL WET PIPE MOUNTED DETAIL

F3

B3

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text

SOUND GENERAL BUILDING ALARM FOR OTHER AND HIGH RISE (NON-HEALTH CARE)

AutoCAD SHX Text NOTIFY NECESSARY STAFF FOR HEALTH CARE AND HIGH RISE BUILDINGS ONLY (ALARM SIGNAL MAY BE DIFFERENT ON DIFFERENT FLOORS)

AutoCAD SHX Text

NOTIFY THE FIRE DEPARTMENT

AutoCAD SHX Text

INITIATE SUPERVISORY SIGNAL TO A 24-HOUR MANNED POINT FOR IMMEDIATE RESPONSE

AutoCAD SHX Text

INITIATE TROUBLE SIGNAL

AutoCAD SHX Text

CLOSE ASSOCIATE SMOKE BARRIER DOORS ON THE FLOOR

AutoCAD SHX Text

CLOSE DAMPERS ON FAN PROXIMATE TO DETECTOR

AutoCAD SHX Text

SHUT DOWN AIR HANDLING UNIT SERVED BY THE DETECTOR

AutoCAD SHX Text

SIGNAL BUILDING MANAGEMENT SYSTEM OF SHUTDOWN EVENT

AutoCAD SHX Text

OPEN LOCKED EGRESS DOORS ON FLOOR OF FIRE ORIGIN

AutoCAD SHX Text

RECALL ELEVATORS TO PRIMARY FLOOR

AutoCAD SHX Text

RECALL ELEVATORS TO SECONDARY FLOOR

AutoCAD SHX Text

DUCT SMOKE DETECTOR

AutoCAD SHX Text

AREA SMOKE DETECTOR

AutoCAD SHX Text

MANUAL PULL STATION

AutoCAD SHX Text

GENERATOR ENCLOSURE HEAT DETECTOR

AutoCAD SHX Text

SPRINKLER WATERFLOW SWITCH

AutoCAD SHX Text

SPRINKLER AND STANDPIPE VALVE TAMPER SWITCH

AutoCAD SHX Text

DRY SPRINKLER HIGH/LOW PRESSURE SWITCH

AutoCAD SHX Text

ELEVATOR RECALL LOBBY SMOKE DETECTOR - PRIMARY FLOOR

AutoCAD SHX Text

ELEVATOR RECALL LOBBY SMOKE DETECTOR - ALTERNATE FLOOR

AutoCAD SHX Text

DRY PIPE SPRINKLER ZONE PRESSURE SWITCH

AutoCAD SHX Text

1. ACTIVATION OF ANY ALARM OR SUPERVISORY INITIATING DEVICE SHALL ACTIVATION OF ANY ALARM OR SUPERVISORY INITIATING DEVICE SHALL INITIATE FUNCTIONS CONSISTENT WITH THE EXISTING FIRE ALARM SYSTEM PROGRAMING. ALARM SIGNALS IN INDIVIDUAL SMOKE COMPARTMENTS SHALL BE COORDINATED WITH THE FIRE/SMOKE BARRIERS AND SPRINKLER ZONES.

AutoCAD SHX Text

FIRE ALARM MATRIX NOTES:

AutoCAD SHX Text

NTS

AutoCAD SHX Text

NTS

AutoCAD SHX Text F I R S T A V E N U E

AutoCAD SHX Text A S S E R L E V Y P L A C E

AutoCAD SHX Text E A S T 2 3 r d. S T R E E T

AutoCAD SHX Text

BLDG 3

AutoCAD SHX Text

BLDG 2

AutoCAD SHX Text

BLDG 4 / 5

AutoCAD SHX Text

E A S T 25 TH STREET

AutoCAD SHX Text

BLDG 1

AutoCAD SHX Text N

AutoCAD SHX Text

BLDG 6

AutoCAD SHX Text

SH

AutoCAD SHX Text

AD

AutoCAD SHX Text

AutoCAD SHX Text

C-FA601

AutoCAD SHX Text

AND OPERATION MATRIX

FIRE ALARM DETAILS

FIRE ALARM RISER DIAGRAM

NTS

F1

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

F i l e

P a t h

P

M

ISSUED FOR

CONSTRUCTION

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

VA NY Manhattan Campus

423 E 23RD Street, New York, NY 10010

630-600A

Project Director

Revisions: Date:

A/E:

AECOM

3101 WILSON BLVD, SUITE 900

ARLINGTON, VA. 22201

703-682-4900

WWW.AECOM.COM

Construction Document Refresh

1 & GEN PLTFRM

Key Plan

Balance of Work

9/12/2022

AutoCAD SHX Text

1. THE FIRE ALARM RISER DIAGRAM ABOVE IS DIAGRAMMATIC AND NOT ALL THE FIRE ALARM RISER DIAGRAM ABOVE IS DIAGRAMMATIC AND NOT ALL COMPONENTS OF THE FIRE ALARM SYSTEM ARE PROVIDED. CONTRACTOR SHALL SUBMIT RISER DIAGRAM WITH ALL NEW DEVICES FROM FLOOR PLANS CONNECTED TO CIRCUITS SHOWN FOR APPROVAL. 2. CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED TO CONTRACTOR SHALL PROVIDE ALL NECESSARY COMPONENTS REQUIRED TO MAKE THE SYSTEM COMPLETE. 3. NOT ALL EXISTING FIRE ALARM DEVICES AND EQUIPMENT ARE SHOWN. NOT ALL EXISTING FIRE ALARM DEVICES AND EQUIPMENT ARE SHOWN. CONTRACTOR IS RESPONSIBLE FOR VERIFYING FIELD CONDITIONS PRIOR TO ANY DEMOLITION OR NEW INSTALLATION WORK ON THE SITE FIRE ALARM SYSTEM. 4. THE EXISTING FIRE ALARM MANUFACTURER IS HONEYWELL-NOTIFIER. THE EXISTING FIRE ALARM MANUFACTURER IS HONEYWELL-NOTIFIER. 5. NEW FIRE ALARM DEVICES INSTALLED IN THE EXISTING BUILDING 1 AND NEW FIRE ALARM DEVICES INSTALLED IN THE EXISTING BUILDING 1 AND BUILDING 6 SHALL BE CONNECTED TO THE EXISTING FIRE ALARM SYSTEM AND TAPPED OFF THE NEAREST EXISTING CIRCUIT WITH SUFFICIENT CAPACITY. 6. COORDINATE DOOR HOLDER INSTALLATION WITH DOOR HARDWARE COORDINATE DOOR HOLDER INSTALLATION WITH DOOR HARDWARE CONTRACTOR, SPECIFICATION SECTION 08 71 00. 7. CLASS AND STYLE OF THE NEW/EXTENDED CIRCUITS SHALL BE SAME AS CLASS AND STYLE OF THE NEW/EXTENDED CIRCUITS SHALL BE SAME AS EXISTING FIRE ALARM CIRCUITS. WIRING FOR THE FIRE ALARM FOR THE BUILDING SHALL BE AS FOLLOWS: SIGNALING LINE CIRCUITS - CLASS B NOTIFICATION APPLIANCE CIRCUITS - CLASS B SPEAKER CIRCUITS - CLASS B COMMUNICATIONS BETWEEN FIRE ALARM CONTROL PANELS - CLASS X 8. THE FIRE ALARM RISER DIAGRAM ABOVE DOES NOT INCLUDE FIRE ALARM THE FIRE ALARM RISER DIAGRAM ABOVE DOES NOT INCLUDE FIRE ALARM SYSTEM INFORMATION FOR LEVEL 2 AND THE ABOVE FLOORS OF THE FACILITY. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF SYSTEM COMPONENTS SUCH THAT WORK ON LEVEL 1 AND THE GROUND LEVEL DO NOT INTERRUPT FIRE ALARM SYSTEM OPERATIONS ON THE REMAINING FLOORS OF THE FACILITY. 9. FIRE ALARM SPEAKERS SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE FIRE ALARM SPEAKERS SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE ALARM SPEAKER CIRCUITS. 10. FIRE ALARM STROBES SHALL BE ALTERNATELY WIRED BETWEEN TWO FIRE ALARM STROBES SHALL BE ALTERNATELY WIRED BETWEEN TWO NOTIFICATION APPLIANCE CIRCUITS. 11. THE FIRE ALARM RISER DIAGRAM ABOVE SHOWS GENERAL INFORMATION THE FIRE ALARM RISER DIAGRAM ABOVE SHOWS GENERAL INFORMATION ON THE QUANTITY AND AREA WHERE FIRE ALARM DEVICES AND EQUIPMENT ARE LOCATED. REFER TO FLOOR PLANS FOR EXACT LOCATION OF FIRE ALARM DEVICES. 12. REFER TO FLOOR PLANS FOR CANDELA RATINGS OF FIRE ALARM STROBE REFER TO FLOOR PLANS FOR CANDELA RATINGS OF FIRE ALARM STROBE DEVICES. 13. ALL NEW FIRE ALARM ZONES AND ALARMS SHALL BE SIGNALED ON ALL NEW FIRE ALARM ZONES AND ALARMS SHALL BE SIGNALED ON EXISTING FIRE ALARM PANELS AND ANNUNCIATORS. 14. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY MODULES, CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY MODULES, COMPONENTS, MODIFICATIONS, AND PROGRAMMING AS REQUIRED TO INTERFACE THE NEW FIRE ALARM DEVICES AND EQUIPMENT TO THE EXISTING SYSTEM. 15. DO NOT RUN FIRE ALARM CABLES IN THE SAME RACEWAY AS NON-FIRE DO NOT RUN FIRE ALARM CABLES IN THE SAME RACEWAY AS NON-FIRE ALARM CABLES.

AutoCAD SHX Text

RISER DIAGRAM NOTES:

AutoCAD SHX Text

FIRST FLOOR

AutoCAD SHX Text

GROUND FLOOR

AutoCAD SHX Text

MAIN

AutoCAD SHX Text

FACP

AutoCAD SHX Text

120 VAC

AutoCAD SHX Text

FA

AutoCAD SHX Text

WKSTN

AutoCAD SHX Text

PRN

AutoCAD SHX Text

FA

AutoCAD SHX Text P

AutoCAD SHX Text

MM

AutoCAD SHX Text

BUILDING 1 SPACES

AutoCAD SHX Text

FATC

AutoCAD SHX Text P

AutoCAD SHX Text

GENERATOR PLATFORM

AutoCAD SHX Text

FIRE COMMAND CENTER

AutoCAD SHX Text

FATC

AutoCAD SHX Text P

AutoCAD SHX Text

MM

AutoCAD SHX Text

BUILDING 6 SPACES

AutoCAD SHX Text

MM

AutoCAD SHX Text

FATC

AutoCAD SHX Text

120 VAC

AutoCAD SHX Text

FA

AutoCAD SHX Text

FA

AutoCAD SHX Text

FATC

AutoCAD SHX Text

FA

AutoCAD SHX Text

FA

AutoCAD SHX Text

FA

AutoCAD SHX Text

FA

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

SPKC

AutoCAD SHX Text

NAC

AutoCAD SHX Text

SPKC

AutoCAD SHX Text

NA…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .