The checklist comprises 23 items covering critical safety and operational requirements that contractors must verify before and during crane lifting operations. Key operational requirements include: operator knowledge of load weight and crane rated capacity; crane positioning on level, firm ground with proper outrigger deployment and blocking; clearance of the swing radius from personnel and obstructions; proper load securing, balancing, and hook centering to prevent deflection and side loading; maintenance of clear lift swing paths; use of tag lines for hazardous load rotation; prevention of personnel from standing under or entering load fall zones; adherence to proper signaling procedures; isolated radio communication frequencies for the crane team; prohibition of side and tip loading; smooth acceleration and deceleration; compliance with electrical safety guidelines per NAVFAC P-307; and completion of critical lift regulations with interactive briefings for designated critical lifts. The checklist requires contractor name (printed and signed), location, and date documentation, and must be current, completely filled out, and posted in the crane. The document serves as a standardized safety verification tool to ensure compliance with federal contracting safety requirements for all crane lifting operations.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT "A"
CONTRACTOR CRANE OPERATING CHECKLIST FOR CRITICAL LIFTS YES NO
1 Does the operator know the weight of the load to be lifted?
2 Is the load to be lifted within the crane manufacturer's rated capacity in its present configuration?
3 Is the crane level and on firm ground?
4 Are outriggers required?
5 If so, are outriggers fully extended and down, and the load off the wheels.
6 If blocking is required, is the entire surface of the outrigger pad supported, and is the blocking material of sufficient strength to safely support the loaded outrigger pad?
7 If outriggers are not used, is the crane rated for on-rubber lifts by the manufacturer's load chart?
Is the swing radius of the crane counterweight clear of people, obstructions, and accessible areas within the swing area barricaded to prevent injury, damage and unplanned encroachment?
9 Has the hook been centered over the load in such a manner to prevent swing (deflection, side loading, load-moment)?
10 Is the load well secured and balanced in the sling or lifting device before it is lifted (free and clear) more than a few inches?
11 Is the lift swing path clear of obstructions?
12 If rotation of the load being lifted is hazardous, is tag line or restraint line being used?
13 Are personnel prevented from standing or passing under a suspended load?
14 Are personnel prevented from entering the load fall zone?
15 Is the crane operator's attention diverted?
16 Are proper signals being used at all times?
17 If radio communications are used, is the frequency isolated to the crane team.
18 Do the operations ensure that side and tip loading is prohibited?
19 Are start and stop motions in a smooth fluid motion (no sudden acceleration or deceleration)?
20 If operating near electric power lines, are the rules and guidelines understood and adhered to as specified in NAVFAC P-307?
21 Is the lift a critical lift?
22 If so, are critical lift regulations understood, check-off sheets initialed and signed off, and was there an interactive brief conducted with associated personnel?
23 Is Attachment "A" current, filled out completely, and posted in the crane?