The section includes six attachments that provide essential reference materials and inventory information. Attachment J-1606000-01 defines key acronyms and terminology relevant to water systems, including standards organizations (ANSI, AWWA, NFPA) and regulatory frameworks (NPDWR, NSDWR, USEPA). Attachment J-1606000-02 lists seven technical references governing water conservation, utility distribution, water supply systems, water main disinfection, and Navy overseas drinking water programs. Attachments J-1606000-03 through J-1606000-06 provide operational and inventory data: the water distribution system serves 102 facilities with approximately 3,000 personnel, comprising over 36,000 linear feet of piping across four primary zones, 89 fire hydrants, and over 400 system valves supplied by DC Water through two primary meters near the Visitor Control Center building. The chilled water distribution inventory, fire hydrant inventory, and water meter inventory details are referenced in separate Excel files. The water meters are read monthly and measure water supply consumption for NRL operations. These attachments establish the baseline infrastructure and regulatory requirements that underpin the contract's scope of work for water system operations and maintenance.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION J
DOCUMENTS, EXHIBITS, AND OTHER ATTACHMENTS
TABLE OF CONTENTS
ATTACHMENT
NUMBER
ATTACHMENT TITLE
J-1606000-01 Definitions and Acronyms J-1606000-02 References and Technical Documents J-1606000-03 Water Distribution System Description and Inventory J-1606000-04 Chilled Water Distribution System Inventory J-1606000-05 Fire Hydrant Inventory J-1606000-06 Water Meter Inventory
ATTACHMENT J-1606000-01
DEFINITIONS AND ACRONYMS
Definition/Acronym Description ANSI American National Standards Institute AWWA American Waterworks Association CTO Certificate to Operate DoD FGS Department of Defense Environmental Final Governing Standards NFPA National Fire Protection Association NPDWR National Primary Drinking Water Regulations NSDWR National Secondary Drinking Water Regulations OEBGD Overseas Environmental Baseline Guidance Document OMSI Operation And Maintenance Support Information Potable Water (US and territories)
Water that is satisfactory for drinking and cooking.
UFC Unified Facilities Criteria USEPA US Environmental Protection Agency Water Fit for Human Consumption (Overseas)
Water that meets the primary drinking water standards as defined in FGS, OEBGD and CNICINST 5090.1.
ATTACHMENT J-1606000-02
REFERENCES AND TECHNICAL DOCUMENTS
Reference Title UFC 3-440-02N Water Conservation Operation and Maintenance UFC 3-430-09 Exterior Mechanical Utility Distribution UFC 3-230-02 Water Supply Systems AWWA Standard C651 Disinfecting Water Main CNICINST 5090.1 U.S. Drinking Water Quality Standards for U.S. Navy Installations Overseas CNICINST 5090.2 Overseas Drinking Water Operation and Operator Requirements CNICINST 5090.3 Navy Overseas Drinking Water Program Ashore
ATTACHMENT J-1606000-03
WATER DISTRIBUTION SYSTEM DESCRIPTION AND INVENTORY
The Naval Research Laboratory (NRL) water distribution system provides potable water and fire protection support to 102 facilities, serving a base population of approximately 3,000 personnel. The distribution network consists of over 36,000 linear feet of piping across four primary zones, supported by 89 fire hydrants and over 400 system valves. NRL purchases and receives water from DC Water, with two meters located near the VCC office accounting for over 99% of NRL consumption and an additional water meter for impervious surfaces. The water supply and return lines are below grass, paved parking lots, and roadways.
ATTACHMENT J-1606000-04
Chilled Water Distribution Inventory
See Excel File “ J-1606000-04 Chilled Water Distribution Inventory”.
ATTACHMENT J-1606000-05
Fire Hydrant Inventory
See Excel File “ J-1606000-05 Fire Hydrant Inventory”.
ATTACHMENT J-1605000-06
WATER METER INVENTORY, LOCATION AND SCHEDULE OF READING
Meter Name Location in
Building System Device Function Normal
Reading Main Water Supply
2 Meters Located Near the Visitor Control Center BLDG.
Water Supply Line
Meter Measure Water Supply for NRL
Monthly
File details come from the government source that posted it. Updated .