Attachment D.11 - 10_618-22-100_MPLS_PT_IFB_ELEC_230404.pdf

PDF 10 MB Posted

Attached to
618-22-100 Renovate for Expanded Polytrauma Phase 1
Solicitation number
36C26323R0058_1
Issued by

About this file

This document summarizes a federal construction solicitation for renovations to expand polytrauma care at the Minneapolis VA Medical Center. The solicitation is for general construction, electrical, plumbing and other trades required to complete Phase 1 renovations to expand and consolidate polytrauma care. The solicitation is set aside for verified Service-Disabled Veteran-Owned Small Businesses, with a magnitude of construction estimated between $10-20 million. All applicable taxes shall be included in pricing. The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23.

View the file

Other files

File Type Posted
36C26323R0058 0001.pdf PDF
See Attached document - Attachment 1 Questions and Answers Request 7.12.2023.doc DOC document
See Attached document - Attachment 5 618-22-100 Prebid Sign-in Roster.pdf PDF
See Attached document - Attachment 2 MPLS Expand Polytrauma Program - Pre Bid Walk Through.pdf PDF
See Attached document - Attachment 7 Polytrauma Structural Coordination.pdf PDF
See Attached document - Attachment 6 618-21-700.MPLS.POLYTRAUMA.PG104i.pdf PDF
See Attached document - Attachment 4 Polytrauma Addendum Summary.docx DOCX document
See Attached document - Attachment 3 Site Visit Agenda Poly Trauma Agenda June 26 2023.docx DOCX document
Attachment D.5 - 4_618-22-100_MPLS_PT_IFB_EQUIP_230404.pdf PDF
Attachment C Specifications Polytrauma 1477 pages.pdf PDF
Attachment D.7-6_618-22-100_MPLS_PT_IFB_PLUMB_230404.pdf PDF
Attachment D.9 - 8_618-22-100_MPLS_PT_IFB_MECH_230404.pdf PDF
Attachment A - Final SOW-618-22-100 - REV4 4.18 (6 pages).pdf PDF
Attachment I VAAR 852.219-75 Limitations on Subcontracting Cert of Compliance (2 Pages).pdf PDF
Attachment F - VA6500 Appendix C and Appendix D.pdf PDF
Attachment H Questions Request Form (1 page).doc DOC document
Attachment K Combined Single Source Justifications_Redacted.pdf PDF
Attachment D.1 - 618-22-100_MPLS_PT_IFB_GENERAL_230404.pdf PDF
Attachment E - 618-22-100_MPLS_PT_TripleC-CA-SubmittalLOG.xlsx XLSX spreadsheet
Attachment D.2 - 2_618-22-100_MPLS_PT_IFB_ARCH_230404.pdf PDF
Attachment J Wage Determination MN20230117 05.19.2023.pdf PDF
Attachment D.3 - 3_618-22-100_MPLS_PT_IFB_INTERIORS_230404.pdf PDF
Attachment D.12 - 11_618-22-100_MPLS_PT_IFB_TELECOM_230404.pdf PDF
Attachment B Price Schedule Breakdown (1 Page).pdf PDF
Attachment F - VA6500 Appendix C 1-2-3a-6a-7a-7d-9 and Appendix D (6 pages).pdf PDF
Attachment D.4 - 4_618-22-100_MPLS_PT_IFB_EQUIP_230404 (2).pdf PDF
Attachment D.1 - 4_618-22-100_MPLS_PT_IFB_EQUIP_230404.pdf PDF
Attachment D.1 - 4_618-22-100_MPLS_PT_IFB_EQUIP_230404 (1).pdf PDF
Attachment D.6 -5_618-22-100_MPLS_PT_IFB_FIRE_230404.pdf PDF
Attachment G - Past Performance Questionnaire (3 Pages).docx DOCX document
36C26323R0058 1.pdf PDF
Attachment F - VA6500 Appendix C 1-2-3a-6a-7a-7d-9 and Appendix D.pdf PDF
Attachment D.10 - 9_618-22-100_MPLS_PT_IFB_MECH_230404.pdf PDF
Attachment D.8 - 7_618-22-100_MPLS_PT_IFB_PLUMB_230404.pdf PDF
Attachment D.4 - 4_618-22-100_MPLS_PT_IFB_EQUIP_230404.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ELECTRICAL ABBREVIATIONS

J J

J

M

V

SP

R

GB

VFD

LCP

LRP

AFB

NCC

MS

1P

2P

E

DS

SS

B

MO

FBX

ET

M

M

C

DTDT

A-1

PH

D

P

K a

L

OS

R

B

CB

MD

MD

SP

VP

TV

XX

DC

C

DM

R/D

DGP

RX

ELM

DO

AC

K

AC

E

K

ATS

TBB

T

TMH

EMH

EHH

X

PSD

EMU

FB

UG

GB

G

PB

SR-X

6-30R

UPS

CT

DOOR CONTACT SWITCH

ACCESS FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED)

FLOOR BOX ("X" DENOTES TYPE AS SPECIFIED)

CONTACTOR

VARIABLE FREQUENCY DRIVE/VARIABLE FREQUENCY MOTOR CONTROLLER

MANUAL MOTOR STARTER WITH PILOT LIGHT AS INDICATED.

PUSHBUTTON STATION

CCTV SURVEILLANCE CAMERA OUTLET - WALL MTD, UON

DOOR MONITOR SWITCH

RECEIVER/DRIVER UNIT

NURSE CALL CONTROL EQUIPMENT PANEL (RECESSED/SURFACE)

NURSE CALL EMERGENCY STATION - PULL CORD TYPE IN

TOILETS & SHOWERS, PUSH-BUTTON TYPE IN ALL OTHER

PLACES

NURSE CALL BEDSIDE STATION, DOUBLE PATIENT

NURSE CALL BEDSIDE STATION, SINGLE PATIENT

NURSE CALL MASTER STATION

GLASS BREAK DETECTOR

NURSE CALL DOME LIGHT

PATIENT MONITORING OUTLET

CODE BLUE CALL STATION

NURSE CALL STAFF STATION

NURSE CALL DUTY STATION

LIGHTING FIXTURE TYPE DESIGNATION - "XX" INDICATES SPECIFIC TYPE

EXIT LIGHT - WALL/CEILING MOUNTED - DIRECTIONAL

ARROWS AS INDICATED SHADING INDICATES ILLUMINATED

FACE

LIGHTING TRACK - "X" DENOTES TYPE

UTILITY LIGHTING FIXTURE - TYPE AS INDICATED

WALL MOUNTED LIGHTING FIXTURE- TYPE AS INDICATED

SITE LIGHTING FIXTURE TYPE AS INDICATED

LIGHTING FIXTURE - TYPE AS INDICATED (SUBSCRIPT INDICATES SWITCH CONTROL)

JUNCTION BOX - CEILING OR WALL MOUNTED - INDICATED IN POWER, LIGHTING & FIRE

ALARM SYSTEMS PLANS.

DIRECT CONNECTION TO EQUIPMENT

SINGLE POLE SWITCH (SUBSCRIPT INDICATES FIXTURES CONTROLLED)

DIMMER SWITCH

SINGLE OR DOUBLE, REMOTE EMERGENCY LIGHTING FIXTURE

THREE-WAY SWITCH (S3P-THREE-WAY SWITCH WITH PILOT LIGHT)

KEY OPERATED SWITCH

SINGLE POLE SWITCH WITH PILOT LIGHT

FOUR - WAY SWITCH

FUSED SWITCH

DELTA CONNECTION

CPT

PASSIVE INFRARED/ULTRASONIC OCCUPANCY SENSOR (WALL/CEILING)

ELECTRIC INTERLOCK SYSTEM

CONTROL POWER TRANSFORMER

CURRENT TRANSFORMER

POTENTIAL TRANSFORMER

PHOTO CELL

KEY INTERLOCKING SYSTEM

WYE CONNECTION - SOLID GROUND

SWITCH - SINGLE THROW

TELECOMMUNICATIONS BACKBOARD

MOTOR CONTROL CENTER

TELEPHONE MANHOLE

ELECTRIC MANHOLE

FUSE

BUS DUCT PLUG-IN UNIT

GROUND

AUTOMATIC TRANSFER SWITCH

DRAWOUT TYPE, CIRCUIT BREAKER

STATIONARY CIRCUIT BREAKER

DISCONNECT SWITCH, FUSED.

PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY,

UON

GROUND ROD

DISCONNECT SWITCH, NON-FUSED

PROVIDE SWITCH AMPACITY EQUAL TO OR GREATER THAN FEEDER AMPACITY, UON

TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, FLOOR MTD SERVICE FITTING,

SURFACE TYPE ("F" DENOTES FLUSH TYPE, "P" DENOTES POKE THRU TYPE)

TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, WALL MTD.

(SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

TRANSFORMER - TYPE AND RATING AS INDICATED

COMBINATION MOTOR STARTER WITH DISCONNECT SWITCH.

PROVIDE SWITCH AND FUSE AMACITY EQUAL TO OR GREATER THAN FEEDER

AMPACITY, UON

PANELBOARD - (FLUSH/SURFACE)

DISTRIBUTION PANELBOARD

ELECTRIC HANDHOLE

LIGHTING CONTROL PANEL, SURFACE MTD. UON.

LOW VOLTAGE LIGHTING RELAY PANEL, SURFACE MTD. UON

UNINTERRUPTIBLE POWER SUPPLY

SHADING INDICATES FIXTURE [CONNECTED TO CRITICAL BRANCH]

[CONNECTED TO GENERATOR CIRCUIT (SWITCHED)]

[W/FLUORESCENT BATTERY/INVERTER UNIT (SWITCHED)]

SHADING INDICATES FIXTURE [CONNECTED TO LIFE SAFETY BRANCH

(UNSWITCHED)] [W/FLUORESCENT BATTERY/INVERTER UNIT (UNSWITCHED)]

a

LOW VOLTAGE SWITCH

JUNCTION BOX - FLOOR MOUNTED

TELECOMMUNICATIONS COMBINATION VOICE/DATA OUTLET, CEILING MTD SERVICE

FITTING,

SURFACE TYPE ("F" DENOTES FLUSH TYPE)

MOTOR AND CONNECTION

EMERGENCY POWER OFF

REQUEST-FOR-EXIT SENSOR

ELECTRIC LOCKING/LATCHING AND MONITORING HARDWARE

ACCESS CONTROL STATION - KEYPAD TYPE

ACCESS CONTROL STATION - CARD TYPE

DOOR OPERATING EQUIPMENT

DATA GATHERING PANEL

NURSE CALL DOME LIGHT CEILING MTD

("Z" SUBSCRIPT DENOTES ZONE DOME LIGHT)

CODE BLUE WITH RED PHONE, WALL MTD, MOUNTED 48" AFF

CODE BLUE WITH BLUE LIGHT, WALL MTD, MOUNTED 48" AFF

MOTION DETECTOR - CEILING MTD

MOTION DETECTOR - WALL MTD

POWER SUPPLY FOR DOOR(S) WITH ELECTRICAL HARDWARE

CEILING MOUNTED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W.

SPECIAL PURPOSE RECEPTACLE. TYPE AS INDICATED ON DRAWINGS.

COORDINATE RECEPTACLE TYPE WITH ACTUAL EQUIPMENT PRIOR TO INSTALLATION.

SWITCHED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W.

EMERGENCY DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W.

FLOOR MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V,

2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON

FACEPLATE.

FLOOR MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX

RECEPTACLES WITH A COMMON FACEPLATE.

FLOOR MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.

FLOOR MOUNTED DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. PROVIDE CORE

DRILL PACKAGE TO MAINTAIN FIRE RATING OF FLOOR. EXTEND CONDUIT

AND WIRING IN CEILING SPACE OF FLOOR BELOW TO ELECTRICAL CLOSET

OR PANELBOARD.

FLOOR MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.

CEILING MOUNTED QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V,

2P, 3W, DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON FACEPLATE.

FLOOR MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W.

CEILING MOUNTED DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.

CEILING MOUNTED SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.

CEILING MOUNTED SINGLE RECEPTACLE, 20A, 125V, 2P, 3W.

SINGLE ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P,

3W. (SLASH INDICATES MOUNTING ABOVE FINISH

COUNTER)

QUADRUPLEX ISOLATED GROUND RECEPTACLE, (2)20A, 125V, 2P, 3W,

DUPLEX ISOLATED GROUND RECEPTACLES WITH A COMMON

FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

DUPLEX ISOLATED GROUND RECEPTACLE, 20A, 125V, 2P, 3W.

(SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

SINGLE RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

RECEPTACLES MOUNTED ABOVE THE CEILING.

QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX RECEPTACLES

WITH A COMMON FACEPLATE. (SLASH INDICATES MOUNTING ABOVE FINISH

COUNTER)

CEILING MOUNTED QUADRUPLEX RECEPTACLE, (2)20A, 125V, 2P, 3W, DUPLEX

RECEPTACLES WITH A COMMON FACEPLATE.

GFI, DUPLEX RECEPTACLE, 20A, 125V, 2P, 3W. (SLASH INDICATES MOUNTING ABOVE FINISH COUNTER)

ELECTRONIC METERING UNIT

GROUND BUS

GROUND CABLE, SIZE AS INDICATED

PLUG-IN BUSWAY

FEEDER BUSWAY

UNDERGROUND CONDUIT/DUCTBANK

CABLE TRAY

CONDUIT TURNED DOWN

CONDUIT TURNED UP

CONDUIT CAST IN CONCRETE OR BELOW SLAB

CONDUIT RUN CONCEALED IN FINISHED AREAS, EXPOSED IN UNFINISHED

AREAS OR BELOW ACCESS FLOORS

HOMERUN TO PANEL WITH CIRCUIT NUMBER(S) AS INDICATED

TELECOMMUNICATIONS DATA OUTLET ABOVE CEILING

COMBINATION TV OUTLET AND DUPLEX RECEPTACLE ON SINGLE

FACEPLATE

SPEAKER - WALL MTD

PA VOLUME CONTROL

MICROPHONE OUTLET - CEILING MTD

MICROPHONE OUTLET - WALL MTD

MICROPHONE OUTLET - FLOOR MTD

SPEAKER - CEILING MTD

RECORDING OUTLET

COMBINATION VIDEO PROJECTOR OUTLET AND DUPLEX RECEPTACLE

CLOCK OUTLET, W/RECPT AND HANGER

CLOCK OUTLET, MASTER CLOCK

CLOCK OUTLET, ELAPSED TIME

GENERATORG

SURFACE RACEWAY ("X" DENOTES TYPE AS SPECIFIED)

WALLWASH LIGHT FIXTURE,

DEMOLITION WORK

OCCUPANCY SENSOR WALL SWITCH

M

HC ADA PUSH BUTTON.

ELECTRICAL LIGHTING SYMBOLS ELECTRICAL POWER SYMBOLS GENERAL NOTES

A INTERCOMMUNICATION SYSTEM ( AI PHONE)

A B C A B C

P P

PD PD

D D

POWER SERVICE FITTING (FLOOR/WALL) MOUNTED FOR CONNECTION TO FURNITURE

SYSTEM AS SPECIFIED.

COMBINATION POWER AND TELECOMMUNICATIONS FLOOR OR WALL MOUNTED BOX FOR

POWER AND DATA CONNECTION - INDICATED IN POWER & SPECIAL SYSTEMS PLANS.

JUNCTION BOX FLOOR OR WALL MOUNTED FOR CONNECTION TO FURNITURE SYSTEM

MOUNTING HEIGHT NOTES:

1. ALL ELEVATIONS ARE TO CENTER LINE OF DEVICE, UNLESS OTHERWISE NOTED.

2. REFER TO EQUIPMENT ELEVATION DRAWINGS FOR COORDINATION WITH

CASEWORK.

3. MOUNT MANUAL MOTOR STARTER ADJACENT TO OR ON UNIT.

4. REFER TO ARCHITECTURAL A0 SERIES FOR ADDITIONAL ELECTRICAL DEVICE

MOUNTING HEIGHTS AND DEVICE ALIGNMENT RULES.

WALL SWITCHES

RECEPTACLES

TELECOMMUNICATIONS OUTLETS

TELECOMMUNICATIONS OUTLETS - WALL PHONE

CLOCK OUTLETS

TV OUTLETS

PUSHBUTTONS

VOLUME CONTROLS

NURSE CALL STATIONS

NURSE CALL DOME LIGHTS

DIMMERS

ACCESS CONTROL DEVICES

VANITY LIGHT IN TOILET

INTERCOM

FIREMAN'S PHONE

FIRE ALARM - PULL STATIONS

FIRE ALARM DEVICES HORN/SPEAKERS/STROBES

(MOUNTING HEIGHT AT THE TOP OF THE FIRE ALARM DEVICE OR

6" BELOW CEILING WHICH IS LOWER)

4'-0" AFF

1'-6" AFF

1'-6" AFF

4'-0" AFF

7'-0" AFF

1'-6" AFF

4'-0" AFF

4'-0" AFF

4'-0" AFF

7'-6" AFF

4'-0" AFF

4'-0" AFF

6" ABOVE THE MIRROR, UON

4'-0" AFF

4'-0" AFF

4'-0" AFF

7'-2" AFF TO TOP

PROVIDE 1#12 + 1#12N + 1#12G FOR 20A BRANCH CIRCUITING, UON; MAXIMUM OF

THREE CIRCUITS PER CONDUIT; MINIMUM CONDUIT SIZE OF 3/4" C, UON.

PROVIDE A DEDICATED NEUTRAL WIRE FOR EACH BRANCH CIRCUIT.

COORDINATE DEVICE LOCATIONS AND MOUNTING HEIGHTS WITH ARCHITECTURAL

DRAWINGS PRIOR TO ROUGH-IN.

PROVIDE FIRE STOPPING FOR CONDUITS AND ELECTRICAL EQUIPMENT FOR FLOOR

SLABS, WALLS AND CEILINGS TO MAINTAIN FIRE RATING.

INSTALL ELECTRICAL WORK IN ACCORDANCE WITH THE NATIONAL ELECTRICAL

CODE AND LOCAL BUILDING AND FIRE CODES, IN A NEAT AND WORKMANLIKE

MANNER.

LIMIT VOLTAGE DROP TO 2% FOR FEEDERS AND 3% FOR BRANCH CIRCUITS. INCLUDE

DERATING FACTOR FOR ROOF-MOUNTED CONDUITS.

REFER TO ARCH. REFLECTED CEILING PLANS FOR EXACT LOCATION OF CEILING

MOUNTED DEVICES AND LIGHT FIXTURES, UNLESS OTHERWISE INDICATED.

WHERE MULTIPLE SWITCHES, RECEPTACLES, AND OTHER OUTLETS (EXCEPT WALL

PHONES) ARE INDICATED PROVIDE MULTI-GANG BACK BOXES WITH GANG BARRIERS

AND A COMMON FACEPLATE.

WHERE DIFFERENT RECESSED ELECTRICAL DEVICES WITH THE SAME MOUNTING

HEIGHTS ARE INDICATED SIDE-BY-SIDE, MOUNT THE DEVICES SO THAT THERE IS

FOUR INCHES BETWEEN ADJACENT VERTICAL EDGES OF THE FACEPLATES, UON.

WHERE UPDATE TO TECHNOLOGY (LOW VOLTAGE/SIGNAL) ARE LOCATED IN THE

SAME AREA ALIGN DEVICES VERTICALLY THROUGH THEIR CENTERLINES, UON.

WHERE EXIT SIGNS ARE INDICATED ABOVE DOOR MOUNT AS FOLLOWS, CENTER THE

EXIT SIGN BETWEEN TOP OF DOOR FRAME AND CEILING IF DISTANCE BETWEEN TOP

OF DOOR FRAME AND CEILING IS 24 INCHES OR LESS; OTHERWISE MOUNT BOTTOM

OF EXIT SIGN 6 INCHES FROM TOP OF DOOR FRAME, MOUNT OTHER WALL MOUNTED

EXIT SIGNS IN THE SAME AREA AT THE SAME HEIGHT. COORDINATE WITH

ARCHITECTURAL DETAILS.

EXIT SIGNS ARE TO BE TYPE "X1", UON.

PROVIDE SEPARATE NEUTRALS FOR DIMMING CIRCUITS.

PROVIDE FEEDERS AND BRANCH CIRCUITS WHICH HAVE AN AMPACITY EQUAL TO OR

GREATER THAN THE CIRCUIT OVERCURRENT PROTECTIVE DEVICE RATING, U.O.N.

FURNITURE LAYOUTS ARE FOR REFERENCE ONLY. COORDINATE THE FINAL

LOCATION OF ELECTRICAL DEVICES AND OUTLETS WITH ARCHITECT, OWNER AND

FINAL FURNITURE PLANS PRIOR TO INSTALLATION.

MOUNT DEVICES FLUSH WITH CONCEALED CONDUIT, EXCEPT AS NOTED ON THE

DRAWINGS AND IN MECHANICAL AND ELECTRICAL EQUIPMENT ROOMS.

THE DRAWINGS REPRESENT ELECTRICAL DESIGN INTENT. THEY ARE DIAGRAMMATIC.

PROVIDE ALL COMPONENTS NECESSARY FOR COMPLETE OPERATING ELECTRICAL

SYSTEMS.

WHEN MORE THAN ONE 20A., 1P., 120 VOLT CIRCUIT FEEDS A SURFACE RACEWAY

CONNECT RECEPTACLES TO ALTERNATE CIRCUITS AS FOLLOWS - U.O.N.

A.

B.

C.

D.

E.

F.

G.

H.

J.

K.

L.

M.

N.

O.

P.

Q.

R.

ELTD EMERGENCY LIGHTING TRANSFER DEVICE

SECURITY SYSTEM SYMBOLS

TELECOMMUNICATION SYMBOLS

NURSE CALL SYSTEM SYMBOLS

MOUNTING HEIGHTS

ELECTRICAL EQUIPMENT SYMBOLS

ELECTRICAL WIRING SYMBOLS

DISTRIBUTION AND DIAGRAM SYMBOLS

REFERENCE SYMBOLS

SECTION NUMBER

DETAIL NUMBER

DRAWING NUMBER WHERE DRAWN

DRAWING NUMBER WHERE DRAWN

E1-1.0

KEY NOTE

1 DEMO KEY NOTE

SPECIAL SYSTEM OUTLET SYMBOLS

CB

E1-1.0

DISCONNECT SWITCHES

MOTOR STARTERS

PANELBOARDS & CABINETS

INDIVIDUAL CIRCUIT BREAKERS

5'-6" AFF

5'-6" AFF

6'-0" AFF TO TOP

5'-6" AFF

x

WAP WIRELESS ACCESS POINT, CEILING MOUNTED

NOTE: NOT ALL ABBREVIATIONS AND

SYMBOLS APPLY TO THIS PROJECT.

SPST

SWBD

SYM

STD

SW

SPEC(S)

SPDT

SPKR

SF

SEC

SINGLE POLE SINGLE THROW

SINGLE POLE DOUBLE THROW

SYMMETRICAL

SWITCHBOARD

STANDARD

SWITCH

SECONDARY

SQUARE FOOT

SPECIFICATION(S)

SPEAKER

PRI

RCLP

RM

SCH, SCHED

RP

REF

RCPT

RSC

RLA

RF

R, RE

QTY

PWR

PT

PVC

PA

PH, ∅

PF

PNL

PE

PB

P

OPP

OHE/T

OH

OFOI

OFCI

NO., NUM, #

OC

NTS

AMERICAN WIRE GAUGE

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AUTOMATIC TRANSFER SWITCH

AMPERE INTERRUPTING CAPACITY

ALTERNATING CURRENT

ABOVE FINISHED COUNTER

AWG

BLDG

BRKR, BKR

BUILDING

BREAKER

AUTO

AUX

ARCH

AT

ATS

ALT

AFG

AIC

AFC

AFF

AC

AF

AUXILIARY

ALTERNATE

ARCHITECT

AUTOMATIC

AMPERES TRIP

AMPERE FRAME (BREAKER RATING)

MTG

NC

NEMA

NO

NIC

NEC

N

MV

MH

MOCP

MTD

MLO

MIN

MISC

MECH

MCC

MFR

MCA

MCB

RIGID STEEL CONDUIT

RATED (RUNNING) LOAD AMPS

RECEPTACLE PANELBOARD

ROOM

SCHEDULE

RADIO FREQUENCY

RECEPTACLE

REFRIGERATOR

RELOCATE AS SHOWN

POTENTIAL TRANSFORMER

POLYVINYL CHLORIDE

REMOTE CONTROL LIGHTING PANEL

QUANTITY

POWER

PUBLIC ADDRESS

PANEL

PRIMARY

PULL BOX

POWER FACTOR

PHOTO ELECTRIC

PHASE

POLE

OPPOSITE

OWNER FURNISHED, CONTRACTOR INSTALLED

OWNER FURNISHED, OWNER INSTALLED

OVERHEAD ELECTRIC/TELEPHONE

OVERHEAD

ON CENTER

NOT TO SCALE

NUMBER

MOUNTING

NATIONAL ELECTRICAL CODE

MEDIUM VOLTAGE (OVER 600V LESS THAN 35KV)

NORMALLY CLOSED

NORMALLY OPEN

NOT IN CONTRACT

NEUTRAL

MINIMUM CIRCUIT AMPACITY

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAXIMUM OVERCURRENT PROTECTION

MOUNTED

MISCELLANEOUS

MAIN LUGS ONLY

MINIMUM

MANHOLE

MANUFACTURER

MECHANICAL

SWGR SWITCHGEAR

AIR HANDLING UNITAHU

MTS MANUAL TRANSFER SWITCH

PDP POWER DISTRIBUTION PANEL

AMPERESAMP

OCPD OVERCURRENT PROTECTION DEVICE

A M

B N

O

P

Q

R

S

T

SPD SURGE PROTECTIVE DEVICE

OD OUTLET DESIGNATOR

LOW VOLTAGE (BELOW 50 VOLTS)

L-L

L-N

LTG

LV

LIGHTING

LINE TO LINE

LINE TO NEUTRAL

1000 CIRCULAR mils

KILOVOLTS (THOUSAND VOLTS)

KILOWATTS (THOUSAND WATTS)

LIGHTNING ARRESTOR

LOCAL AREA NETWORK

KILOVOLTS-AMPERES (THOUSAND VOLT-AMPS)

ISOLATED GROUND

KWH

LAN

LA

KW

KVA

Kcmil

KV

KILOWATT-HOURS

INCAND

KEY INTERLOCK

JUNCTION BOX

INCH/INCHES (")

INCANDESCENT

GROUND FAULT INTERRUPTER

HAND-OFF-AUTOMATIC

HIGH PRESSURE SODIUM

HEATING VENTILATION AND AIR CONDITIONING

HERTZ

HVAC

HZ

HTR

HR

HT

HPS

HOA

HP

HEATER

HEIGHT

HORSEPOWER

HOUR

GFI

G, GND, GRD

GEN

FLUOR

FL, FLR

GROUND

GENERATOR

FOOT/FEET (')

FLUORESCENT

FLOOR

CATV

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

FIRE ALARM ANNUNCIATOR PANEL

ELECTRIC, ELECTRICAL

ELECTRIC METALLIC CONDUIT

EQUIPMENT GROUND

EWC

FAAP

FLA

FDR

EWH

FA

FULL LOAD AMPS

FEEDER

FIRE ALARM

FUSE

ELEC

EQ, EQUIP

EM, EMERG

EMT

ELEV

ENCL

EG

EQUIPMENT

ELEVATOR

EMERGENCY

ENCLOSURE

DISTRIBUTION PANEL

DOUBLE POLE SINGLE THROW

DOUBLE POLE DOUBLE THROW

CONTROL POWER TRANSFORMER

CURRENT TRANSFORMER

DPDT

DWG

DPST

DIST

DISC

DC

DP

DN

DRAWING

DISTRIBUTION

DIRECT CURRENT

DISCONNECT

DOWN

CPT

CU

CT

COM, COMM

CKT

CLG

COPPER

COMMUNICATIONS

CIRCUIT

CEILING

CABLE TELEVISION

CB CIRCUIT BREAKER

CONDUIT

FIRE ALARM CONTROL PANELFACP

FIRE ALARM EXTENDER PANELFAEP

CCTV CLOSED CIRCUIT TELEVISION

CP CONTROL PANEL

FLEX FLEXIBLE

HAND HOLEHH

LIGHTING CONTROL PANELLC, LCP

LIGHTING PANEL

L-G LINE TO GROUND

C

F

EXISTINGE, EX, EXIST

FT

IN

IG

JB, JBOX

K

LP

FOOT CANDLEFC

DIV DIVISION

C

D

E

F

G

H

I

J

K

L

HORIZONTAL MOUNTINGH

COR CONTRACTING OFFICER'S REPRESENTATIVE

X

XFMR

WP

WHM

W/

W/O

W

VFD

VA

V

UPS

UL

UON

UG

UGS

UGT

UGP

TYP

TV

TP

TEL,TELE

TELECOM

TC

TRANSFORMER

REMOVE DEVICE

WATT HOUR METER

WEATHERPROOF

VOLTS

VARIABLE FREQUENCY DRIVE/

VARIABLE FREQUENCY MOTOR

CONTROLLER

WITHOUT

WITH

WIRE

VOLT-AMPERES

UNDERGROUND PRIMARY

UNDERGROUND SECONDARY

UNDERGROUND TELEPHONE

UNDERWRITER'S LABORATORY

UNLESS OTHERWISE NOTED

UNINTERRUPTIBLE POWER SUPPLY

UNDERGROUND

TELECOMMUNICATIONS

TYPICAL

TELEVISION

TAMPERPROOF

TIME CLOCK

TELEPHONE

TB TERMINAL BLOCK

TBB TELEPHONE BACKBOARD

U

V

W

X

Z

TPST TRIPLE POLE SINGLE THROW

FDS FORWARD DEPLOYED SERVICES

JOINT SECURITY ARCHITECTUREJSA

PIV PERSONAL IDENTITY VERIFICATION

EMERGENCY GFI, DUPLEX RECEPTACLE (SLASH INDICATES MOUNTING ABOVE

FINISHED COUNTER).

on e-ei gh th in ch o ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in es ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLAN

A/E:

TRIPLE C - The A/E Group

Mat Perkins

(520) 481-8548

A

B D

EF

G

H

J

K

L

M

C

LINE INDICATES

PHASE 1 SCOPE AREA

B

IM

/6

-2

-1

E x p a n d e d P o ly tr a u m a P ro g ra m P h a s e

/6 -2

-7

.M

P L S

.P O

L Y

T R

A U

M A

.G e n e ra l.

S h e e ts

.r v t

/3

/2

:4

:3

P

M 1 : 1

04/03/2023 K. Luke K.Hutchinson

618-22-100

1390 - E-001

ELECTRICAL ABBREVIATIONS AND SYMBOLS

1 Veterans Drive, Minneapolis, MN 55417

B70

RENOVATE FOR EXPANDED

POLYTRAUMA PROGRAM

ISSUED FOR BIDDING

04/03/2023

O S

OS

F

T

F

T

O S

O S

O S

O S

Z Z

TTUUVVWWXXYY

AREA NOT IN SCOPE OF WORK

ALL ELECTRICAL LIGHTING DEVICES ARE EXISTING TO REMAIN

AREA NOT IN SCOPE OF WORK

ALL ELECTRICAL LIGHTING DEVICES ARE EXISTING TO REMAIN

TYP.

TYP.

TYP.

TYP.

TYP.

/F6 EDL104/F6 EDL104

TTUUVVWWXX

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

/F1 EDL104 /F1 EDL104

4K-102

4K-102A 4K-105

4K-125 4K-123

4K-122

4K-128

4K-1274K-129

C4-135

C4-131

4K-113

4K-112

4K-140

4K-117

4K-119

4K-120

4K-143

4K-141

4K-139

4K-137

4K-135

4J-101

4K-138

4K-136

4K-136A

4K-134A

4K-134

4K-133A

4K-133

4K-132

4K-131A

4K-140A

4K-138A

4K-142A

4K-142

C4-135

SW8

C4-138

4K-114

4K-107

4K-111

4K-130

4K-130A

4K-116

4K-118

4K-121

C4-133

C4-132

C4-134

4K-126

4K-131

C4-127

4K-109

4K-108

4K-106

4K-104

4K-124 4K-124A

4K-124B

SW7

4K-103

4K-101

4H-108

4H-108A

4K-110

4K-115

4G-109B

4G-111

4G-112

4G-114

4S-6 4H-121

4H-122

4H-123

C4-116

4G-116 4G-115 4G-111C 4G-111B 4G-111A

4H-114

4H-115 4H-116 4H-117

4H-118

4H-120

E

C-6

M-8

4L-101

4L-140

C4-126

C4-115

C4-137

4L-102

4L-102A

4K-101

4H-108

SW8

4H-102

4H-103

4H-104

4H-105

4H-106

4H-107

4H-108A

4H-109 4H-110

4H-111

4H-113

4G-117

4H-101A

4H-101B

C4-110

C4-114

C4-138

4H-112

4H-101

4H-101D

4H-101C

4H-101E

WALL SYMBOL LEGEND

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

PROPOSED EXTERIOR WALL.

SEE WALL SECTIONS

1 HR FIRE AND SMOKE

BARRIER

2 HR FIRE AND SMOKE

BARRIER (SHAFT)

SMOKE BARRIER PARTITION

DEMOLISHED WALL,

FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE

OR FURNISHING TO REMAIN

NOT IN CONTRACT - NO

WORK SCHEDULED

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLAN

A/E:

TRIPLE C - The A/E Group

Mat Perkins

(520) 481-8548

A

B D

EF

G

H

J

K

L

M

C

GENERAL NOTES

KEYNOTES

LINE INDICATES

PHASE 1 SCOPE AREA

B

IM

/6

-2

-1

E x p a n d e d P o ly tr a u m a P ro g ra m P h a s e

/6 -2

-7

.M

P L S

.P O

L Y

T R

A U

M A

.M E

P .B

.L

.r v t

/3

/2

:2

:2

P

M As indicated

04/03/2023 K. Luke K.Hutchinson

618-22-100

1390 -

EDL104

ELECTRICAL DEMO LIGHTING RCP - FOURTH

LEVEL - AREA 4H&4K

1 Veterans Drive, Minneapolis, MN 55417

B70

RENOVATE FOR EXPANDED

POLYTRAUMA PROGRAM - PHASE 1

ISSUED FOR BIDDING

1. REMOVE ALL EXISTING LIGHT FIXTURES AND CONTROLS .

2. PROVIDE NEW LIGHT FIXTURE, SEE LUMINAIRE SCHEDULE ON SHEET E-701 FOR

ADDITIONAL INFORMATION.

3. DEMOLISH EXISTING PANELBOARD, REPLACE WITH NEW PANELBOARD, SIZE AS

INDICATED ON ELECTRICAL PANEL SCHEDULES AND ELECTRICAL ONE-LINES.

REPLACE CIRCUIT BREAKER, SOURCE FEEDER AND REPLACE ALL EXISTING

CIRCUITS TO NEW PANELBOARD AS INDICATED. SEE E-600 AND E-700 SERIES

SHEETS FOR ADDITIONAL INFORMATION.

4. UNLESS OTHERWISE NOTED, REMOVE ALL EXISTING ELECTRICAL DEVICES

ASSOCIATED WITH THE AREA OF WORK FROM ENDPOINT DEVICE TO

ASSOCIATED SOURCE PANEL TO PREPARE THE SPACE FOR RENOVATION. ALL

DEVICE/CIRCUITS NOT ASSOCIATED WITH THE LOCAL DEMOLITION SHALL BE

PROTECTED AND ENSURE THAT CIRCUITS REMAIN IN SERVICE PER CONDITIONS

PRIOR TO DEMOLITION. ALL DEMOLITION / PHASING SHALL BE COORDINATED

WITH THE VA COR.

5. EXISTING AREA TO REMAIN, PROTECT IN PLACE

6. EXISTING ELECTRICAL PANEL TO REMAIN, PROTECT IN PLACE.

7. NEW PANELBOARD, SIZE AS INDICATED ON ELECTRICAL PANEL SCHEDULES AND

ELECTRICAL ONE-LINES. SEE E-600 AND E-700 SERIES FOR ADDITIONAL

INFORMATION.

8. EXISTING ELECTRICAL EQUIPMENT TO REMAIN, PROTECT IN PLACE.

9. DEMOLISH EXISTING TRANSFORMER, REPLACE WITH NEW TRANSFORMER, SIZE

AS INDICATED ON ELECTRICAL PANEL SCHEDULES AND ELECTRICAL ONE-LINES.

SEE E-600 AND E-700 SERIES SHEETS FOR ADDITIONAL INFORMATION.

10. DEMOLISH EXISTING DISCONNECT FOR PANELS BEING REPLACED, REPLACE

WITH NEW DISCONNECT, SIZE AS INDICATED ON ELECTRICAL PANEL

SCHEDULES AND ELECTRICAL ONE-LINES. SEE E-600 AND E-700 SERIES SHEETS

FOR ADDITIONAL INFORMATION.

11. EXISTING LIFE SAFETY PANEL TO BE CONNECTED TO SUB-PANEL ON FOURTH

LEVEL.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM

THOSE INDICATED.

C. MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.

D. CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS

WITH VA COR PRIOR TO ROUGH-IN.

E. PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED

OUTDOORS.

F. SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL

SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.

G. COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH

EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.

H. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING

PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.

I. UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.

J. NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE

OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.

K. CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH

EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.

L. CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN

PLENUM SPACES.

M. REFER TO E-901 FOR CUTSHEETS.

N. COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF

PANELBOARDS.

O. LOCATED DISCONNECT SWITCHES TO MAINTAIN WORKING

CLEARANCES PER NEC 110.26.

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET

SCALE: 1/8" = 1'-0"

F1

ELECTRICAL DEMO LIGHTING RCP -

FOURTH LEVEL - AREA 4H

SCALE: 1/8" = 1'-0"

F6

ELECTRICAL DEMO LIGHTING RCP -

FOURTH LEVEL - AREA 4K

J

J

J

J J

J

C R

J

J J

J

J

J

J

J J

J J

J J

JJ

J

J

JJ

JJ

J

J

J

J

J

J

J

J

J

J

CR

CR

F

T

F

T

J

J

C R

ES

D C

R X

J

J J

J J

J

J

J

J

J

J

J

J

TTUUVVWWXX

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

ROTOCHAIR

(E) NT4H1-1

11 11

(E) NL4H1-1B

(E) NL4H1-1A

(E) NH4H1-1

(E

C L4

H 1-

/F2 EDP104/F2 EDP104

TTUUVVWWXXYY

4J-101

AREA NOT IN SCOPE OF WORK

ALL ELECTRICAL POWER DEVICES ARE EXISTING TO REMAIN

AREA NOT IN SCOPE OF WORK

ALL ELECTRICAL POWER DEVICES ARE EXISTING TO REMAIN

TYP.

TYP.

TYP.

(E) NT4F1-1

20 21

(E) NH4F1-1

(E) CL4F1-1

(E) NL4F1-1B

(E) NL4F1-1A

/F6 EDP104 /F6 EDP104

TYP.

4K-142A

4K-142

4K-140

4K-140A

4K-138A

4K-138

4K-136

4K-136A

4K-134

4K-134A

4K-133A

4K-133

4K-132

4K-131A

4K-131

4K-129

4K-126

4K-127

4K-125 4K-123 4K-122 C4-132 4K-120 4K-121

4K-119

C4-133

4K-117

4K-109

4K-108

4K-106

4K-104

4K-103

4K-101

4H-108

4K-102

4K-107

4K-113

4K-112

4K-105

4K-102A

4K-124

4K-124A

4K-124B

SW7

4K-118

4K-128

4K-130

4K-130A

4K-121A

4K-115

4K-110

4K-111

C-7

C4-131

4K-114

4K-135

4K-137

4K-139

4K-141

4K-143

C4-135

C4-134

C4-138

C4-127

SW8

4H-108A

4K-116

4G-109B

4G-111

4G-112

4G-114

4S-6

4H-121

4H-122

4H-123

C4-116

4G-116 4G-115 4G-111C 4G-111B 4G-111A

4H-114

4H-115 4H-116 4H-117

4H-118

4H-120

E

C-6

M-8

4L-101

4L-140

C4-126

C4-115

C4-137

4L-102

4L-102A

4H-102

4H-103

4H-104

4H-105

4H-106

4H-107

4H-109 4H-110

4H-111

4H-113

4G-117

4H-101A

4H-101B

C4-110

C4-114

4H-112

4K-101

4H-108C4-138

4H-108A

WALL SYMBOL LEGEND

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

PROPOSED EXTERIOR WALL.

SEE WALL SECTIONS

1 HR FIRE AND SMOKE

BARRIER

2 HR FIRE AND SMOKE

BARRIER (SHAFT)

SMOKE BARRIER PARTITION

DEMOLISHED WALL,

FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE

OR FURNISHING TO REMAIN

NOT IN CONTRACT - NO

WORK SCHEDULED

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLAN

A/E:

TRIPLE C - The A/E Group

Mat Perkins

(520) 481-8548

A

B D

EF

G

H

J

K

L

M

C

GENERAL NOTES

KEYNOTES

LINE INDICATES

PHASE 1 SCOPE AREA

B

IM

/6

-2

-1

E x p a n d e d P o ly tr a u m a P ro g ra m P h a s e

/6 -2

-7

.M

P L S

.P O

L Y

T R

A U

M A

.M E

P .B

.L

.r v t

/3

/2

:2

:3

P

M As indicated

04/03/2023 K. Luke K.Hutchinson

618-22-100

1390 -

EDP104

ELECTRICAL DEMO POWER PLANS- FOURTH

LEVEL - 4H&4K

1 Veterans Drive, Minneapolis, MN 55417

B70

RENOVATE FOR EXPANDED

POLYTRAUMA PROGRAM - PHASE 1

ISSUED FOR BIDDING

SCALE: 1/8" = 1'-0"

F6

ELECTRICAL DEMO POWER PLAN -

FOURTH LEVEL - AREA 4K

SCALE: 1/8" = 1'-0"

F2

ELECTRICAL DEMO POWER PLAN -

FOURTH LEVEL - AREA 4H

1. REMOVE ALL EXISTING LIGHT FIXTURES AND CONTROLS .

2. REMOVE ALL EXISTING ELECTRICAL OUTLETS AND FEEDERS BACK TO THE

SOURCE PANEL. PROVIDE NEW ELECTRICAL DEVICES FOR THE RENOVATION.

3. PROVIDE NEW LIGHT FIXTURE, SEE LUMINAIRE SCHEDULE ON SHEET E-701 FOR

ADDITIONAL INFORMATION.

4. PROVIDE NEW LIGHT SWITCH, SEE E-900 SERIES FOR ADDITIONAL

INFORMATION.

5. PROVIDE NEW ELECTRICAL OUTLETS.

6. SEE SHEET E-601 FOR ADDITIONAL ONE-LINE INFORMATION.

7. REMOVE FEEDERS SERVING MECHANICAL EQUIPMENT TO BE REPLACED WITH

THIS PROJECT. PROVIDE NEW FEEDERS. AIR HANDLING UNIT, EXHAUST AND

RETURN FANS SHALL BE SERVED FROM AN EMERGENCY POWER SOURCE.

8. PROVIDE A CODE SIZED RECESSED JBOX WITH A 1-1/4" CONDUIT STUBBED

ABOVE CEILING FOR NURSE CALL DEVICE.

9. PROVIDE 120V CIRCUIT TO SERVE ROLLER BLINDS, SEE ARCH PLANS FOR

DETAILS.

10. PROVIDE 120V CIRCUIT TO SERVE NEW PLUMBING FIXTURES. SEE 22 40 00 FOR

DETAILS.

11. DEMOLISH EXISTING PANELBOARD, REPLACE WITH NEW PANELBOARD, SIZE AS

INDICATED ON ELECTRICAL PANEL SCHEDULES AND ELECTRICAL ONE-LINES.

REPLACE CIRCUIT BREAKER, SOURCE FEEDER AND REPLACE ALL EXISTING

CIRCUITS TO NEW PANELBOARD AS INDICATED. SEE E-600 AND E-700 SERIES

SHEETS FOR ADDITIONAL INFORMATION.

12. UNLESS OTHERWISE NOTED, REMOVE ALL EXISTING ELECTRICAL DEVICES

ASSOCIATED WITH THE AREA OF WORK FROM ENDPOINT DEVICE TO

ASSOCIATED SOURCE PANEL TO PREPARE THE SPACE FOR RENOVATION. ALL

DEVICE/CIRCUITS NOT ASSOCIATED WITH THE LOCAL DEMOLITION SHALL BE

PROTECTED AND ENSURE THAT CIRCUITS REMAIN IN SERVICE PER CONDTIONS

PRIOR TO DEMOLITION. ALL DEMOLITION / PHASING SHALL BE COORDINATED

WITH THE VA COR.

13. EXISTING LIGHTING/RECEPTACLES TO REMAIN, PROTECT IN PLACE.

14. PROVIDE 120V CIRCUIT TO SERVE NEW ACCESS CONTROLS. SEE

ARCHITECTURAL DOOR SCHEDULE FOR ADDITIONAL INFORMATION.

15. PROVIDE 120V CONNECTION TO 24V TRANSFORMER FURNISHED WITH

RESPECTIVE MONITORS AND PRESSURE SENSORS. COORDINATE EXACT

LOCATION WITH MECHANICAL CONTRACTOR PRIOR TO ROUGH-IN.

16. EXISTING ELECTRICAL PANEL TO REMAIN, PROTECT IN PLACE.

17. NEW PANELBOARD, SIZE AS INDICATED ON ELECTRICAL PANEL SCHEDULES AND

ELECTRICAL ONE-LINES. SEE E-600 AND E-700 SERIES FOR ADDITIONAL

INFORMATION.

18. EXISTING ELECTRICAL EQUIPMENT TO REMAIN, PROTECT IN PLACE.

19. PROVIDE NEW 30kW TRANSFORMER IN LOCATION INDICATED ON PLAN, COORDINATE WITH NEW AND EXISTING CONDITIONS. SEE E-600 AND E-700

SERIES FOR ADDITIONAL INFORMATION.

20. DEMOLISH EXISTING TRANSFORMER, REPLACE WITH NEW TRANSFORMER, SIZE

AS INDICATED ON ELECTRICAL PANEL SCHEDULES AND ELECTRICAL ONE-LINES.

SEE E-600 AND E-700 SERIES SHEETS FOR ADDITIONAL INFORMATION.

21. DEMOLISH EXISTING DISCONNECT FOR PANELS BEING REPLACED, REPLACE

WITH NEW DISCONNECT, SIZE AS INDICATED ON ELECTRICAL PANEL

SCHEDULES AND ELECTRICAL ONE-LINES. SEE E-600 AND E-700 SERIES SHEETS

FOR ADDITIONAL INFORMATION.

22. PROVIDE NEW ELECTRICAL DISCONNECT FOR PANELBOARD, SIZE AS

INDICATED.

23. PROVIDE NEW CEILING MOUNTED PHOTOCELL, SEE E-900 SERIES SHEETS FOR

ADDITIONAL INFORMATION.

24. PROVIDE 120V CONNECTION TO SERVE PLUMBING FIXTURE POWER SUPPLY.

25. COORDINATE RECEPTACLE WITH FOOTWALL FOR TV.

26. PROVIDE NEW ACCESS CONTROL PER SPECIFICATIONS. HDP12 COMPLIANT,

CARD READER WITH PINPAD CARD, PIV READY. REFERENCE CUTSHEETS ON

SHEET 09E-901.

27. NEW PSX-75-E1 POWER SOLUTIONS BACKUP POWER FOR iSTAR DOOR

CONTROLLERS. PROVIDE A 20 AMP CIRCUIT PER NEC AND MANUFACTURERS

RECOMMENDATIONS.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM

THOSE INDICATED.

C. MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.

D. CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS

WITH VA COR PRIOR TO ROUGH-IN.

E. PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED

OUTDOORS

F. SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL

SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.

G. COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH

EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.

H. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING

PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.

I. UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.

J. NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE

OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.

K. CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH

EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.

L. CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN

PLENUM SPACES.

M. REFER TO E-901 FOR CUTSHEETS.

N. COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF

PANELBOARDS.

O. LOCATED DISCONNECT SWITCHES TO MAINTAIN WORKING

CLEARANCES PER NEC 110.26.

NOTE: NOT ALL KEYNOTES

ARE USED ON EACH SHEET

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J

J J

J

J

J

J

JJ

J

J

J

J

J

J

J

J

J

J

J J

J

J

J

TTUUVVWWXXYY

70-RF-152

NOT IN SCOPE

NOT IN SCOPE

/F6 EDP104i /F6 EDP104i

TTUUVVWWXX

70-RF-145

70-RF-146

70-RF-152

TYP.

TYP.

TYP.

TYP.

/F2 EP104i /F2 EP104i

WALL SYMBOL LEGEND

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

PROPOSED EXTERIOR WALL.

SEE WALL SECTIONS

1 HR FIRE AND SMOKE

BARRIER

2 HR FIRE AND SMOKE

BARRIER (SHAFT)

SMOKE BARRIER PARTITION

DEMOLISHED WALL,

FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE

OR FURNISHING TO REMAIN

NOT IN CONTRACT - NO

WORK SCHEDULED

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLAN

A/E:

TRIPLE C - The A/E Group

Mat Perkins

(520) 481-8548

A

B D

EF

G

H

J

K

L

M

C

GENERAL NOTES

KEYNOTES

LINE INDICATES

PHASE 1 SCOPE AREA

B

IM

/6

-2

-1

E x p a n d e d P o ly tr a u m a P ro g ra m P h a s e

/6 -2

-7

.M

P L S

.P O

L Y

T R

A U

M A

.M E

P .B

.L

.r v t

/3

/2

:2

:3

P

M As indicated

04/03/2023 K. Luke K.Hutchinson

618-22-100

1390 - EDP104i

ELECTRICAL DEMO POWER PLAN - FOURTH

LEVEL INTERSTITIAL - AREA 4H & 4K

1 Veterans Drive, Minneapolis, MN 55417

B70

RENOVATE FOR EXPANDED

POLYTRAUMA PROGRAM - PHASE 1

ISSUED FOR BIDDING

1. WALLS SHOWN ON PLAN ARE FROM THIRD LEVEL BELOW FOR REFERENCE

ONLY.

2. ELECTRICAL JUNCTION BOX TO BE DEMOLISHED. INFILL OR CLOSE

PENETRATION WITH MATERIALS THAT MEET REQUIRED FIRE RATING OF

EXISTING CONCRETE SLAB.

A. CONTRACTOR SHALL COORDINATE ALL EQUIPMENT, DUCTWORK AND PIPING

WITH STRUCTURAL, MECHANICAL, AND ELECTRICAL SYSTEMS AND SHALL

PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN

REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.

B. EXISTING CONDITIONS ARE BASED ON EXISTING PLANS AND FIELD VERIFICATION

WHERE FEASIBLE. CONSTRUCTION AREA CONDITIONS MAY DIFFER FROM

THOSE INDICATED.

C. MINIMUM BRANCH CIRCUIT SIZE SHALL BE 2#12, 1#12G., 3/4"C.

D. CONTRACTOR SHALL COORDINATE FINAL POINT OF CONNECTIONS

WITH VA COR PRIOR TO ROUGH-IN.

E. PROVIDE NEMA 3R ENCLOSURES FOR EQUIPMENT INSTALLED

OUTDOORS

F. SIZE BRANCH CIRCUITS AND FEEDERS TO EQUIPMENT PER PANEL

SCHEDULE AND FEEDER AND BRANCH CIRCUIT SIZING TABLE ON E-701.

G. COORDINATE FINAL EQUIPMENT CONNECTIONS AT EQUIPMENT WITH

EQUIPMENT SUPPLIER, PRIOR TO ROUGH-IN.

H. LABEL DEVICE PLATES WITH A PERMANENT ADHESIVE LABEL LISTING

PANEL AND CIRCUIT FEEDING THE WIRING DEVICE.

I. UPDATE PANEL SCHEDULES AFFECTED BY RENOVATION.

J. NEW CIRCUIT BREAKERS PROVIDED SHALL MATCH THE EXISTING TYPE

OF CIRCUIT BREAKERS IN PANEL BEING RENOVATED.

K. CONTRACTOR SHALL FIELD COORDINATE CABLE TRAY LAYOUT WITH

EXISTING UTILITIES ROUTED THROUGH THE RENOVATED SPACE.

L. CONTRACTOR SHALL COMPLY WITH NEC 300.22 FOR CONDUIT ROUTED IN

PLENUM SPACES.

M. REFER TO E-901 FOR CUTSHEETS.

N. COMPLY WITH NEC 220.87 FOR ALL 30-DAY LOAD MEASUREMENTS OF

PANELBOARDS.

O. LOCATED DISCONNECT SWITCHES TO MAINTAIN WORKING

CLEARANCES PER NEC 110.26.

1/8" = 1'-0" F1

ELECTRICAL DEMO POWER PLAN - FOURTH LEVEL INTERSTITIAL - AREA H

1/8" = 1'-0"

F6

ELECTRICAL DEMO POWER PLAN - FOURTH LEVEL INTERSTITIAL - AREA K

OS

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D3

D

D3

D

D

D3

D3

O S

D

PHD

D D

D

D3 D3

D3D3D

D3 D3

D3D3

D3 D3

D3D3

D3

D3 D3

D3

D3 D3

D3D3

D3D3

D3D3

D3 D3

D3D3

D3D3D3 D3

D

D

D3 D3

D3 D3

D3D3

D3D3

D3D3

D3D3

D3D3

D3D3

D D

D

DD

D

DD

D

DD

DD

D

D

DD

DD

D

DD

D

D D

D

D D

D

DD

D

DD

D

D

D

D

D

D D

D

D

D

D

D

D

D

D

D

D

D

D

D

PH

PH

PH

PH

PH

PH

PH

PH

PH

PH

PH

PH

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D

D D

TTUUVVWWXXYY

AREA NOT IN SCOPE OF WORK

AREA NOT IN SCOPE OF WORK

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

4G-111

4G-112

4G-114

4S-6

4G-116 4G-115 4G-111C 4G-111B 4G-111A

E 4L-101

4L-140

C4-125

4L-102

4L-102A

4J-101

4J-1024J-103

4J-102B 4J-103B

4J-102A4J-103A

C4-142

C4-141

C4-139

4H-110

4H-113

4H-114

4H-115

C4-115

4H-106

4H-111

4H-107

4H-105

4H-102 4H-101

4H-104

4H-104A

4H-107A

4H-109

4H-103

C4-137

C4-114

C4-126

4K-101

4K-127

4H-108A

4H-108

4K-103A

4K-149

4H-100

4K-152

TYP.

NL4H1-1A- 4

NL4H1-1A- 1

CL4F1-1

NH4F1-1NL4F1-1B

NL4F1-1A

NL4F1-1A- 5

NL4F1-1A- 5

NL4F1-1A- 5

NL4F1-1A- 5 NL4F1-1A- 5 NL4F1-1A- 5 NL4F1-1A- 5NL4F1-1A- 5LL4H1-1- 2

NL4F1-1A- 5

NL4F1-1A- 5 NL4F1-1A- 5 NL4F1-1A- 5 NL4F1-1A- 5

NL4F1-1A- 5

NL4F1-1A- 5 NL4F1-1A- 5 LL4H1-1- 2 NL4F1-1A- 5 NL4F1-1A- 5

LL4H1-1- 2

NL4F1-1A- 5

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

NL4F1-1A- 15CL4F1-1- 2NL4F1-1A- 15

NL4F1-1A- 15 NL4F1-1A- 15 NL4F1-1A- 15

NL4F1-1A- 15NL4F1-1A- 15CL4F1-1- 2

NL4F1-1A- 15

CL4F1-1- 2

NL4F1-1A- 16 CL4F1-1- 6

CL4F1-1- 6NL4F1-1A- 16

NL4F1-1A- 16

NL4F1-1A- 16

NL4F1-1A- 16

CL4F1-1- 6 CL4F1-1- 6

CL4F1-1- 6

NL4F1-1A- 4

NL4F1-1A- 4

LL4H1-1- 2 LL4H1-1- 2

CL4H1-1- 1

NL4H1-1A- 5 NL4H1-1A- 5

NL4H1-1A- 5

CL4F1-1- 7NL4F1-1A- 17

LL4H1-1- 6

LL4H1-1- 6

CL4H1-1- 1

CL4H1-1- 1 CL4H1-1- 1

NL4H1-1A- 5

NL4H1-1A- 5

CL4H1-1- 1

NL4F1-1A- 17 NL4F1-1A- 17CL4F1-1- 7

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 9

NL4H1-1A- 7

NL4H1-1A- 7

LL4H1-1- 2

NL4F1-1A- 4

NL4F1-1A- 4

NL4F1-1A- 4

NL4F1-1A- 5

NL4F1-1A- 4 NL4F1-1A- 4

NL4H1-1A- 6 NL4H1-1A- 6NL4H1-1A- 6

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4F1-1A- 4

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

TR4H-118A

TR4H-118B

TR4H-118A- 3

TR4H-118A- 3 TR4H-118A- 3

TR4H-118A- 3

NL4F1-1A- 4

NL4F1-1A- 4NL4F1-1A- 4

CL4F1-1- 1NL4F1-1A- 4NL4F1-1A- 4

CL4F1-1- 1 NL4F1-1A- 4

I

I I I

I

II

I

III

I I I

III

I

I

I

I

I I

I

I

I

I

E

E

E

E

E

E

E E

E E E E E E

E E

E

E E

E

E

E E E

E

E

E

E

E

E

E

E

E E

E

E E

EEE

E

E

E

E

EEEEEEEEE

EEEE

E E E E

E

E

E

E

E E

E

E

E

E

I

I

NL4H1-1A- 7

I I

SW8

A A

C

NL4H1-1A- 7

TR4H-118A- 3

TR4H-118A- 3

LL

4H

-1

LL

4H

-1

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

LL4H1-1- 2

NL4F1-1A- 6

NL4F1-1A- 6NL4F1-1A- 6NL4F1-1A- 6

NL4F1-1A- 6 NL4F1-1A- 6

I I I

I I I

E

E

NL4F1-1A- 5

NL4F1-1A- 5

NL4F1-1A- 4 NL4F1-1A- 4

C C

Z

Z

Z

Z

Z Z

Z

Z

G G G

F

NL4H1-1A- 5

CL4H1-1- 1

E

CL4H1-1- 1CL4H1-1- 1

AA

TYP.

NL4F1-1A- 8NL4F1-1A- 8NL4F1-1A- 8

I

CL4F1-1- 6

NL4F1-1A- 4

E

LL

4H

-1

2Z

LL4H1-1- 2 Z

4H-123

NL4F1-1A- 5

NL4F1-1A- 5

E

E

HAC

4H-112

CORR.

C4-137A

/F6 EL104 /F6 EL104

NL4F1-1A- 17

NL4F1-1A- 17

NL4F1-1A- 17 NL4F1-1A- 17

NL4F1-1A- 17

E

E

E E

E

TTUUVVWWXX

N H

4H 1-

C L4

H 1-

NL4H1-1A

NL4H1-1B

AREA NOT IN SCOPE OF WORK

4K-116B

4K-118

4K-117

4K-116C

4K-116D

4K-116A

4K-116

4K-128

4K-109

4K-126

4K-121

4H-110

4H-113

4K-123

4K-122

4K-120

4K-119A

4K-120A

4K-122A

4K-123A

4K-106

4K-104

4K-102

4H-111

4K-111

C4-135

C4-127

4K-101

4K-127

4K-119

4K-107

4K-103

4K-105

4K-108

4K-110

4K-112

4K-105A

4K-108A

4K-110A

4K-112A

4K-113

4K-114

4K-113A

4K-114A

4K-115

C4-131

4K-115A

4K-103A

4K-151

4K-155

4K-154

4K-153

4K-150

4K-149

SW7

C4-132

4K-152

TYP.

TYP.

TYP.

TYP.

CL4H1-1- 7 CL4H1-1- 7

CL4H1-1- 7CL4H1-1- 7

CL4H1-1- 7

CL4H1-1- 7

CL4H1-1- 7

CL4H1-1- 7

CL4H1-1- 7

CL4H1-1- 7 CL4H1-1- 7

CL4H1-1- 7CL4H1-1- 7

CL4H1-1- 7CL4H1-1- 7

CL4H1-1- 1CL4H1-1- 1

CL4H1-1- 1 CL4H1-1- 1

CL4H1-1- 1CL4H1-1- 1CL4H1-1- 1

CL4H1-1- 1

CL4H1-1- 1

CL4H1-1- 1

CL4H1-1- 1

CL4H1-1- 1CL4H1-1- 1

CL4H1-1- 1

CL4H1-1- 3 CL4H1-1- 3

CL4H1-1- 3 CL4H1-1- 3

CL4H1-1- 3

CL4H1-1- 3CL4H1-1- 3

CL4H1-1- 3

CL4H1-1- 3 CL4H1-1- 3

CL4H1-1- 3

CL4H1-1- 3CL4H1-1- 3CL4H1-1- 3CL4H1-1- 3

CL4H1-1- 4 CL4H1-1- 4

CL4H1-1- 4 CL4H1-1- 4

CL4H1-1- 4CL4H1-1- 4CL4H1-1- 4

CL4H1-1- 4

CL4H1-1- 4 CL4H1-1- 4

CL4H1-1- 4CL4H1-1- 4

CL4H1-1- 4 CL4H1-1- 4CL4H1-1- 4

CL4H1-1- 4

CL4H1-1- 5

CL4H1-1- 5

CL4H1-1- 5CL4H1-1- 5

CL4H1-1- 5

CL4H1-1- 5 CL4H1-1- 5

CL4H1-1- 5

CL4H1-1- 5CL4H1-1- 5CL4H1-1- 5

CL4H1-1- 5 CL4H1-1- 5 CL4H1-1- 5

CL4H1-1- 5

CL4H1-1- 11

CL4H1-1- 11 CL4H1-1- 11CL4H1-1- 11

CL4H1-1- 11CL4H1-1- 11

CL4H1-1- 11

CL4H1-1- 11

CL4H1-1- 11

CL4H1-1- 11

CL4H1-1- 11CL4H1-1- 11

CL4H1-1- 11 CL4H1-1- 11

CL4H1-1- 2NL4H1-1A- 7CL4H1-1- 2

CL4H1-1- 2

CL4H1-1- 2

LL4H1-1- 6

LL4H1-1- 6

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 1

NL4H1-1A- 4

NL4H1-1A- 4

NL4H1-1A- 4

NL4H1-1A- 4

NL4H1-1A- 4

LL4H1-1- 6

LL4H1-1- 6

LL4H1-1- 6

LL4H1-1- 6

LL4H1-1- 6

LL4H1-1- 6

LL4H1-1- 6

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 26

NL4H1-1A- 5

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 7

NL4H1-1A- 7

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 9

CL4H1-1- 1 NL4H1-1A- 5

CL4H1-1- 1

NL4H1-1A- 6 NL4H1-1A- 6 NL4H1-1A- 6

NL4H1-1A- 6NL4H1-1A- 6NL4H1-1A- 6

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 8

NL4H1-1A- 8NL4H1-1A- 8

NL4H1-1A- 8

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

NL4H1-1A- 7

CL4H1-1- 29

NL4H1-1A- 7

CL4H1-1- 29

NL4H1-1A- 7

CL4H1-1- 29

NL4H1-1A- 8 NL4H1-1A- 8CL4H1-1- 31

LL

H 1-

4K-156

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

EE

EEE

E

E

E

E

E E E

EEE

E

EE

E

E

E

E

E E

A

A

I

I I

I

AA

A

A A

II

A A A

AA

A A

A A

A A

AAA

A A

A

A

A

A A A

A A

A A

A A A

AA

AA

I

A A

A

AA

A

A

I

A A A

AA

AA

A A

A A

AAA

A

A

A

AA

AA

A A

A A

AAA

I

A

A

A

A A

I

I

B

B

B

B

B

B

B

BB

B

B

B

B

AIA

I

I

I

I

C

C

C

C

C

C

C

C

C

C

C

C

I

I

TYP.

LL4H1-1- 6

LL4H1-1- 6 LL4H1-1- 6

NL4H1-1A- 7

I

NL4H1-1A- 4 NL4H1-1A- 4

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

F

I

LL4H1-1- 6

NL4H1-1A- 7

NL4H1-1A- 7

C

C 4

ZZ

Z

D

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 6

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 26

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

NL4H1-1A- 5

D

D

D

D

D

D

D

D

D

D

D

I I I

NL4H1-1A- 8 NL4H1-1A- 8 NL4H1-1A- 8

NL4F1-1A- 6NL4F1-1A- 6NL4F1-1A- 6

III

E

E

E

E

E

E

E

NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

CL4H1-1- 31

NL4H1-1A- 29NL4H1-1A- 29NL4H1-1A- 29NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29 NL4H1-1A- 29 NL4H1-1A- 29 NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29NL4H1-1A- 29NL4H1-1A- 29

NL4H1-1A- 29

NL4H1-1A- 29NL4H1-1A- 29NL4H1-1A- 29NL4H1-1A- 29

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

NL4H1-1A- 22

H H

H H H H

H H

J J

JJ

J

JJJ

J

J

JJJJJ

J J J J

J J

J J J

4K-125

NL4H1-1A- 1 NL4H1-1A- 1 NL4H1-1A- 1

E E E

/F2 EP104 /F2 EP104

J

J

NL4H1-1A- 29 NL4H1-1A- 29

J

CL4H1-1- 31

WALL SYMBOL LEGEND

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

PROPOSED EXTERIOR WALL.

SEE WALL SECTIONS

1 HR FIRE AND SMOKE

BARRIER

2 HR FIRE AND SMOKE

BARRIER (SHAFT)

SMOKE BARRIER PARTITION

DEMOLISHED WALL,

FIXTURE OR FURNISHING

EXISTING WALL, FIXTURE

OR FURNISHING TO REMAIN

NOT IN CONTRACT - NO

WORK SCHEDULED

on e-ei gh th ne fo ot on e-qu ar te r ne fo ot th re e-ei gh th s ne fo ot on e-ha lf ne fo ot th re e-qu ar te r ne fo ot in ch on e ne fo ot on e an d on e-ha lf ne fo ot th re e in ne fo ot

REVISIONS DATE

General Notes:

GENERAL CONTRACTOR AND/OR ALL SUBCONTRACTORS SHALL FIELD VERIFY ALL DIMENSIONS SHOWN ON THESE PLANS AND SHALL BE RESPONSIBLE FOR VARIATIONS BETWEEN PLAN DIMENSIONS AND ACTUAL FIELD DIMENSIONS. WHERE VARIATIONS ARE FOUND TO OCCUR, THE CONTRACTOR SHALL NOTIFY THE PROJECT ENGINEER IN WRITING PRIOR TO PROCEEDING WITH CONSTRUCTION; NO ADJUSTMENT TO

THE WORK WILL BE MADE WITHOUT THE PRIOR APPROVAL OF THE PROJECT ENGINEER.

GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERAL DEMOLITION INCLUDING REMOVAL OF WALLS, PARTITIONS, DOORS & CEILING & FLOORS. ANY AND ALL CUTTING OF CONCRETE FLOORS, WALLS OR STRUCTURE SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY. CORE DRILLING THROUGH CONCRETE WALLS, FLOORS OR STRUCTURE FOR PIPING OR CONDUIT SHALL BE THE RESPONSIBILITY OF THE SUBCONTRACTOR BY TRADE; FIRESTOPPING OF THESE OPENINGS SHALL BE DONE BY THE RESPECTIVE SUBCONTRACTOR. REMOVAL OF DEBRIS RESULTING FROM DEMOLITION, CUTTING, AND/OR DRILLING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. PATCHING AND REPAIR OF CONCRETE WALLS, FLOOR, OR STRUCTURE SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR; THIS WILL BE ACCOMPLISHED UPON COMPLETION OF THE INSTALLATION OF ANY AND ALL UTILITIES INSTALLED

BY THE VARIOUS SUBCONTRACTORS.

Approved: Division Chief

Issue Date Checked Drawn

DrawingNumber

Building Number

Project NumberDrawing Title Project Title

Location Drawing Scale

Approved: Service DirectorPlot Scale U.S. Department of Veterans Affairs

Office of Construction and Facilities Management

FULLY SPRINKLERED

Phase

A

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

321 4 5 6 7 8 9 10

TRUE NORTH

PLAN NORTH

KEYPLAN

A/E:

TRIPLE C - The A/E Group

Mat Perkins

(520) 481-8548

A

B D

EF

G

H

J

K

L

M

C

GENERAL NOTES

KEYNOTES

LINE INDICATES

PHASE 1 SCOPE AREA

B

IM

/6

-2

-1

E x p a n d e d P o ly tr a u m a P ro g ra m P h a s e

/6 -2

-7

.M

P L S

.P O

L Y

T R

A U

M A

.M E

P .B

.L

.r v t

/3

/2

:2

:4

P

M As indicated

04/03/2023 K. Luke K.Hutchinson

618-22-100

1390 - EL104

ELECTRICAL LIGHTING RCP - FOURTH LEVEL

- AREA 4H&4K

1 Veterans Drive, Minneapolis, MN 55417

B70

RENOVATE FOR EXPANDED

POLYTRAUMA PROGRAM - PHASE 1

ISSUED FOR BIDDING

1. PROVIDE NEW LIGHT FIXTURE. SEE LUMINAIRE SCHEDULE ON SHEET E-701 FOR

ADDITIONAL INFORMATION.

2. PROVIDE NEW LIGHT SWITCH. SEE E-900 SERIES FOR ADDITIONAL

INFORMATION.

3. NEW PANELBOARD, SIZE AS INDICATED ON ELECTRICAL PANEL SCHEDULES AND

ELECTRICAL ONE-LINES. SEE E-600 AND E-700 SERIES FOR ADDITIONAL

INFORMATION.

4. PROVIDE NEW CEILING MOUNTED PHOTOCELL. SEE E-900 SERIES SHEETS FOR

ADDITIONAL INFORMATION.

5. PROVIDE NEW LUTRON 5-BUTTON LIGHTING CONTROL KEYPAD.

6. MOUNT NIGHT LIGHT (D) AT 22" ON CENTER AFF AND MOUNT VANITY LIGHTS (C)

AT 7'-0" ON CENTER AFF.

7. ALL FIXTURES IN ROOM 4H-118 ARE EXISTING TO REMAIN.

8. LIGHTING FIXTURES ARE EXISTING TO REMAIN.

A. CONTRACTOR SHALL FIELD DEVELOP THE CONDUIT INSTALLATION ALONG

ROUTE SHOWN ON PLANS WITH PULLBOXES AND/OR LB FITTINGS INSTALLED

EVERY 270 DEGREES (MAXIMUM) OF CONDUIT BENDS TO AVOID OBSTRUCTIONS.

PROVIDE FIRE-RATED PENETRATIONS FOR ALL FIRE RATED WALLS AND FLOORS

TO MATCH OR EXCEED THE RATING OF THE WALL OR FLOOR.

B. ALL CONDUITS PENETRATING CONCRETE FLOORS OR WALLS SHALL BE

COORDINATED WITH THE STRUCTURAL ENGINEER OF RECORD (SEOR) PRIOR

TO COMMENCEMENT OF WORK.

C. PROVIDE nLIGHT CONTROLS SYSTEM OR COMPARABLE PRODUCT.

CONTRACTOR IS RESPONSIBLE FOR ALL ENGINEERING FOR SYSTEMS BY OTHER

MANUFACTURERS. REFER TO TYPICAL LIGHTING CONTROL DIAGRAMS ON

SHEETS E600 SERIES FOR EXACT INFORMATION ABOUT PARTS AND MODELS OF

ALL LIGHTING CONTROL SWITCH TYPES AND DEVICES.

D. SHADED LUMINAIRES TO BE ON EMERGENCY POWER.

E. PROVIDE AN UNSWITCHED LEG FOR EMERGENCY LUMINAIRES. ALL EMERGENCY

LUMINAIRES SHALL NOT BE CONNECTED TO nLIGHT CONTROL SYSTEM.

F. REFER TO ARCHITECTURAL RCPs FOR ADDITIONAL NOTES AND

SPECIFICATIONS.

G. COORDINATE WALL MOUNTED LIGHT SWITCHES, DIMMERS AND PRESET

CONTROL STATIONS WITH ARCHITECTURAL INTERIOR ELEVATIONS AND DETAILS

PRIOR TO ROUGH-IN.

H. COORDINATE ALL WALL MOUNTED LIGHT SWITCHES, DIMMERS, AND PRESET

CONTROL STATIONS WITH WALL FINISHES, GLASS PANEL PARTITIONS, FIXED-IN

PLACE FURNITURE, AND MILLWORK PRIOR TO ROUGH-IN.

I. ALL SWITCHES IN OFFICES WITH GLASS PARTITIONS ARE TO BE LOCATED 6"

FROM END OF DOOR WHEN OPENED 90 DEGREES. IF SWITCHES ARE LOCATED

BACK-TO-BACK BETWEEN OFFICES, OFFSET ONE SIDE TO 12" FROM DOOR.

J. ALL ADJACENT SWITCHES AND DIMMING SWITCHED SHALL BE GANGED

TOGETHER TO THE EXTENT PHYSICAL CONDITIONS AND CODE REQUIREMENTS

WILL ALLOW.

K. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING MOUNTING

COMPATIBILITY AND PLENUM CLEARANCE OF ALL LIGHTING FIXTURES AND

SHALL NOTIFY ARCHITECT OF ANY CONFLICT.

L. IN FINISHED INTERIOR AREAS, RUN ALL CONDUITS CONCEALED, UNLESS

OTHERWISE NOTED. PAINT ALL EXPOSED CONDUITS AND ELECTRICAL

EQUIPMENT IN OPEN CEILING AREAS. COORDINATE COLOR SELECTION WITH

ARCHITECT PRIOR TO ROUGH-IN.

SCALE: 1/8" = 1'-0"

F1

ELECTRICAL LIGHTING RCP - FOURTH

LEVEL - AREA 4H

SCALE: 1/8" = 1'-0"

F6

ELECTRICAL LIGHTING RCP - FOURTH

LEVEL - AREA 4K

TTUUVVWWXX

(E

LL

3H

1-

NOT IN SCOPE

E H

3H 1-

NL3H1-2

NL3H1-1B

NL3H1-1A

NH3H1-1 CL3H1-1

NT3H1-1

CL3H1-2

3K-1233K-124A

C3-79

C3-80

3K-122A

3K-121A

3K-120A

3K-119

3K-126

3K-128

3K-125A

3K-127A

3K-129A

3K-128A

3K-114

3K-116

3K-118

C3-81

3K-112 3K-111

3K-113

3K-110

3K-131

3K-106

3K-107

C3-76

C3-75

C3-74

C3-73

3K-101 3K-1023K-138

3K-137A

3K-135A

3K-132A

3K-130A

3K-115A

3K-109A

3K-117A

C3-77

3K-105A

3K-104A

3K-104B

3K-103B

3K-103A

3K-102A

3K-133

10 10

3K-122B

3K-122

3K-124

3K-125

3K-127

3K-121

3K-120

3K-117

3K-115

3K-109

3K-108

3K-129

3K-130

3K-132

3K-113

3K-103

3K-134

3K-135

3K-136

3K-137

WALL SYMBOL LEGEND

CONTRACTOR SHALL CONFIRM ALL FIRE RATED WALL ASSEMBLIES

PROPOSED EXTERIOR WALL.

SEE WALL SECTIONS

1 HR FIRE AND SMOKE

BARRIER

2…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .