This document contains a price list and technical exhibit for a federal contract solicitation to provide protective coatings services. The solicitation is for a broad range of maintenance, repair and minor protective coatings construction work at Joint Base Lewis-McChord in Washington state and supported satellites. The contractor will be required to furnish all materials, equipment, and personnel necessary to manage and complete individual task orders which will vary in size and may include incidental disciplines required for various protective coatings applications. The price list contains over 130 contract line items describing estimated quantities and unit prices for a wide variety of protective coatings and surface preparation services for exterior and interior surfaces of various materials. Services include abrasive blasting, pressure washing, application of various paint and coating systems, flooring, repairs, containment and environmental work.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BASE
| Section B | ||||||
| Price List | ||||||
| PROTECTIVE COATING SERVICES | ||||||
| W911S8-20-B-0002 | ||||||
| CLIN 0001 | SUB CLIN | DESCRIPTION | ESTIMATED QUANTITY | UNIT | UNIT PRICE | ESTIMATED AMOUNT |
| Exterior Surfaces: | ||||||
| 0001 | 0001 | PC (Protective Coatings) for Exterior Wood Siding: | 250,000 | SF | ||
| 0001 | 0002 | PC for Exterior Wood Trim Surfaces: Doors, Door Trim, Window Trim, Fascia Boards, Rakes, Stair Railings: | 50,000 | SF | ||
| 0001 | 0003 | PC for Exterior Wood Soffits, Canopies, and Overhangs: | 27,000 | SF | ||
| 0001 | 0004 | PC for Exterior Cementitious Composition Board, Asbestos Hardboard Surfaces: | 95,000 | SF | ||
| 0001 | 0005 | PC for Exterior Concrete, Concrete Masonry, Brick Surfaces, Stucco, EIFS to receive paint finish: | 225,000 | SF | ||
| 0001 | 0006 | PC for Exterior Concrete, Concrete Masonry, Stucco, EIFS to receive High-Build Elastomeric Coating System: | 50,000 | SF | ||
| 0001 | 0007 | PC for Exterior Concrete Masonry, Brick Surfaces to receive clear sealant finish: | 300,000 | SF | ||
| 0001 | 0008 | PC for Exterior Metal Siding: | 70,000 | SF | ||
| 0001 | 0009 | PC for Exterior Metal Roofing: | 75,000 | SF | ||
| 0001 | 0010 | PC for Exterior Metal Trim: Doors, Door Trim, Window Trim, Stairs, Railing, Platforms, Pipe, Ducts, Vents, Stacks: | 150,000 | SF | ||
| 0001 | 0011 | PC for Exterior Metal Soffits, Canopies, and Overhangs: | 15,000 | SF | ||
| 0001 | 0012 | Apply Non-Skid Coating Surfaces: Porches, Decks, Docks, Steps, and Ramps: | 5,000 | SF | ||
| 0001 | 0013 | PC for Chain Link Fence: | 2,000 | SF | ||
| 0001 | 0014 | PC for Wood Fence: | 2,000 | SF | ||
| 0001 | 0015 | PC for Water tanks; POL Tanks Including Fuel Storage Tanks within 35 foot reach: (Surface Preparation and Prime Coat): Lift not included | 50,000 | SF | ||
| 0001 | 0016 | PC for Water tanks; POL Tanks Including Fuel Storage Tanks within 35 foot reach: (Single Finish Coat): Lift not included | 100,000 | SF | ||
| 0001 | 0017 | Elevated Surfaces (Hangars, Water Tower/Tanks) with reach requirements above 35 feet in height (Surface Preparation and Prime Coat): Lift not included | 125,000 | SF | ||
| 0001 | 0018 | Elevated Surfaces (Hangars, Water Tower/Tanks) with reach requirements above 35 feet in height (Single Finish Coat): Lift not included | 250,000 | SF | ||
| 0001 | 0019 | Application of Stenciled Graphic on Elevated Surfaces (Hangars, Water Tower/Tanks) Any reach requirements: Lift not included | 5,000 | SF | ||
| 0001 | 0020 | Structural Sealant/Caulking (Exterior) | 30,000 | LF | ||
| 0001 | 0021 | PC for Fire Hydrants (Prep, Prime, & Paint): | 50 | EA | ||
| 0001 | 0022 | High Temp Paint; Exhaust Stacks; Jet Blast Deflectors; Incinerators: | 500 | SF | ||
| 0001 | 0023 | Ground Protection (drop cloth, plastic sheeting, etc) | 250,000 | SF | ||
| 0001 | 0024 | Surface Protection (drop cloth, plastic sheeting, etc) | 100,000 | SF | ||
| 0001 | 0025 | Surface Prep- Caulking | 50,000 | LF | ||
| 0001 | 0026 | Pressure Wash/Rinse- Water Only | 200,000 | SF | ||
| 0001 | 0027 | Re-Pointing & Masonry Repairs | 4,000 | SF | ||
| 0001 | 0028 | Toothing Masonry | 1,000 | VLF | ||
| 0001 | 0029 | Chemical & Brush Cleaning-Mold | 20,000 | SF | ||
| 0001 | 0030 | Misc Surface Repairs for Wood Surfaces (Ex: Sub CLINs 0001-0003) | 5,000 | SF | ||
| 0001 | 0031 | Misc Surface Repairs for Concrete Surfaces/Cementitous board (Ex: Sub CLINs 0004-0007) | 5,000 | SF | ||
| 0001 | 0032 | Misc Surface Repairs Metal Surfaces (Ex: Sub CLINs 0008-0011) | 5,000 | SF | ||
| Interior Surfaces: | ||||||
| 0001 | 33 | PC for Interior Walls: Gypsum Wallboard, Hardboard, Plywood, Wood Panel, Plaster, Concrete, Concrete Masonry, Brick, Acoustical Wall Panels, or Metal Wall Panels | 115,000 | SF | ||
| 0001 | 34 | PC for Interior Ceilings: Concrete, Gypsum Wallboard, Plaster, Acoustical, Wood, or Metal: (to 15') | 45,000 | SF | ||
| 0001 | 35 | PC for Interior Metal Surfaces: Doors, Door Trim, Window Trim, Pipe, Radiators, Heaters/Grills, Cabinets, Structural Steel, Sheet Metal, Except Metal Wall Panels: | 18,000 | SF | ||
| 0001 | 36 | PC for Interior Wood Trim Surfaces: Doors, Door Trim, Window Trim, Cabinets, Baseboards, Etc.: (Full coverage including putty & prep) | 5,000 | SF | ||
| 0001 | 37 | Wood Stain | 250 | SF | ||
| 0001 | 38 | Wood Varnish | 2,600 | SF | ||
| 0001 | 39 | Exposed to View Paper Facing of Vapor Barrier Jackets of Presized or Adhesive Finished Glass Cloth over Insulation on Pipes, Ducts and Equipment: | 1,000 | SF | ||
| 0001 | 40 | Primer Coat/Seal Coat for Interior and/or Exterior Surfaces not Previously Finished or to be Finished with a distinctive different color | 300,000 | SF | ||
| 0001 | 41 | Special Interior/Exterior Epoxy Paint for Symbols/Graphics on Asphalt or Uncoated Concrete Floor Surfaces; DV Arrival Walkway: | 500 | SF | ||
| 0001 | 42 | Special Multi-Color Durable Wall Coating (MPI #112)(Large Scale Application): | 10,000 | SF | ||
| 0001 | 43 | Special Spot Repair of Multi-Color Durable Wall Coating (MPI #112)(Under 75 Square Feet per Location): | 10 | EACH | ||
| 0001 | 44 | Surface Preparation:Remove Existing Athletic Floor Coating to Bare Wood and Prepare For New Finish: | 10,000 | SF | ||
| 0001 | 45 | Full coverage application of MFMA SSCLFMGF Athletic Floor Finish (Group-III): | 10,000 | SF | ||
| 0001 | 46 | Application of Gymnasium/ Sports Court Graphics or Lines: | 2,500 | LF | ||
| 0001 | 47 | Repair and/or Replace Damaged Gypsum Wallboard, Hardboard, Plywood, Wood Panel, Plaster, Acoustical Wall Panels, or Metal Wall Panels | 6,000 | SF | ||
| 0001 | 48 | Repairs and/or Replace Damaged Interior Masonry and Brick work: | 500 | SF | ||
| 0001 | 49 | Painting walls, complete, on drywall or plaster. Full coverage with roller, including surface preparation and spot repairs | 150,000 | SF | ||
| 0001 | 50 | Interior Coatings Adder: (wall sections and ceilings over 15') | 10,000 | SF | ||
| 0001 | 51 | Surface Preparation including all cosmetic cracks, pinholes, and dents. (Dents to 4" indiameter) Note: Measured per wall section (base x height) | 150,000 | SF | ||
| 0001 | 52 | Miscellaneous Item Painting (Trim 6" or less, 2 Coats) | 12,000 | LF | ||
| 0001 | 53 | Surface Preservative / Sealant (Clear, 3 Coats) | 50,000 | SF | ||
| 0001 | 54 | Relocate Funishing - up to 100 lbs - (Removal/Protect/Reset is one action, not one each per removal & protection & reset) | 300 | EACH | ||
| 0001 | 55 | Floor Protection | 100,000 | SF | ||
| 0001 | 56 | Surface Protection (furnishings, equipment, etc) | 150,000 | SF | ||
| 0001 | 57 | Caulking | 25,000 | LF | ||
| 0001 | 58 | Surface Cleaning | 40,000 | SF | ||
| 0001 | 59 | Surface Texturing (Medium Knockdown) | 10,000 | SF | ||
| Industrial Floor Coatings: (Spec 03 00 00) | ||||||
| 0001 | 60 | Industrial Flooring: Surface Preparation in accordance with Spec para 3.1.3.1 (General Cleaning), 3.1.3.2 (Shot-Blasting), and 3.1.3.4 (Perimeter Edge Prep): | 15,000 | SF | ||
| 0001 | 61 | Industrial Flooring: Supplemental Surface Preparation in accordance with Spec para 3.1.3.3 (Mechanized Sanding) to Remove Existing Top-Coat: | 15,000 | SF | ||
| 0001 | 62 | Industrial Flooring: Crack & Joint Repair (per Spec para 3.1.3.5) including mechanically cleaning and filling all cracks, gouges, and small spalls along joint edges with epoxy crack filler: | 1,500 | LF | ||
| 0001 | 63 | Industrial Flooring: Treatment of Existing Sealant Joints per Spec Para 3.1.2.1 (Over-Cutting Existing Sealant Joints): | 1,500 | LF | ||
| 0001 | 64 | Industrial Flooring: Treatment of Existing Sealant Joints per Spec Para 3.1.2.2 (Complete Sealant Joint Replacement): | 1,500 | LF | ||
| 0001 | 65 | Industrial Flooring: Application of Chemical-Resistant Urethane (includes Primer, Build-Coat, and/or Top Coat: 4-mil application): | 12,500 | SF | ||
| 0001 | 66 | Industrial Flooring: Application of 100% Solids (Two-Component) Epoxy (includes Primer). 6.6-mil application | 12,500 | SF | ||
| 0001 | 67 | Industrial Flooring: Application of 100% Solids High-Build Epoxy Coating (Build OR Top-Coat Application). 10-mil application | 12,500 | SF | ||
| 0001 | 68 | Industrial Flooring: Application of Non-Slip Traction Grit (30 Mesh Quartz or Aluminum Oxide): Adder | 12,500 | SF | ||
| 0001 | 69 | Industrial Flooring: Application of two-component, moisture-cured, high-traffic Urethane for Graphics and Floor Striping (no greater than 6-inch width): | 10,000 | LF | ||
| Miscellaneous Repair, Environmental Testing, Work Site Containment: | ||||||
| 0001 | 70 | Gypsum Wall Board Joint and Fastener Concealment (Taping) | 2,000 | LF | ||
| 0001 | 71 | Wall and Ceiling Texturing | 6,500 | SF | ||
| 0001 | 72 | Small Area Painting Minimum (less than 10 SF per job order): Includes Repairs & Prep | 25 | Each Order | ||
| 0001 | 73 | Paint Hazard Test (TCLP Metals Test for all surfaces): | 25 | EA | ||
| 0001 | 74 | Hazardous Waste Collection and Disposal (55-Gal Barrels): | 25 | EA | ||
| 0001 | 75 | Surface Prep/Handling Procedures for Lead Painted Wood Trim Surfaces (Average 6-inch Wide Trim Surface): | 1,000 | LF | ||
| 0001 | 76 | Re-Grout Tile (grind out & epoxy grout) | 1,000 | LF | ||
| 0001 | 77 | Acoustic Ceiling Tile | 10,000 | SF | ||
| 0001 | 78 | Historic Surface Repairs (Repair/Replacing Wood to Match Existing) | 1,000 | SF | ||
| 0001 | 79 | Historic Surface Repairs (Repair/Replacing Masonry to Match Existing) | 1,000 | SF | ||
| 0001 | 80 | Critical Barrier Installation to Isolate Occupants form Work Site | 200,000 | SF | ||
| Personnel Lifts and Other Support Equipment: | ||||||
| 0001 | 81 | Swing Stage with Generator Set | 2 | WEEK | ||
| 0001 | 82 | Aeiral lift, up to 30' high - rental per day | 45 | DAY | ||
| 0001 | 83 | Aeiral lift, up to 30' high - rental per week | 20 | WEEK | ||
| 0001 | 84 | Aeiral lift, up to 60' high - rental per day | 30 | DAY | ||
| 0001 | 85 | Aeiral lift, up to 60' high - rental per week | 10 | WEEK | ||
| 0001 | 86 | 3000 Watt Portable Generator | 15 | DAY | ||
| 0001 | 87 | 3000 Watt Portable Generator | 2 | WEEK | ||
| 0001 | 88 | Portable Water Storage Trailer (up to 2,000 gal) | 15 | DAY | ||
| 0001 | 89 | Portable Water Storage Trailer (up to 2,000 gal) | 2 | WEEK | ||
| 0001 | 90 | Scaffolding (5' Wide-Complete) | 5,000 | CSF/MONTH | ||
| 0001 | 91 | Site Fencing | 10,000 | LF/MONTH | ||
| 0001 | 92 | Protective Tenting (Shrink Wrap) | 30,000 | SF | ||
| 0001 | 93 | Fire Alarm Securing and Restoration | 150 | EA | ||
| 0001 | 94 | Move and Reset Equipment and/or Furnishings (over 100 lbs) | 400 | EA | ||
| Abrasive Blasting - Paint Removal - Pressure Washing: | ||||||
| 0001 | 95 | Abrasive Blasting of Painted Surfaces Incorporating Special Environmental Handling Procedures: | 2,000 | SF | ||
| 0001 | 96 | Abrasive Blasting Utilizing Isolated "Wet Spray" Dust Containment - (No Enclosure): | 2,000 | SF | ||
| 0001 | 97 | Sand Blast Wet | 20,000 | SF | ||
| 0001 | 98 | Sand Blast Dry | 15,000 | SF | ||
| 0001 | 99 | Cleaning- Water Blast | 300,000 | SF | ||
| 0001 | 100 | Cleaning- Brush and Blast | 300,000 | SF | ||
| 0001 | 101 | Pressure / Chemical Cleaning | 300,000 | SF | ||
| 0001 | 102 | Water Collection, Testing, and Storm Sewer disposal | 50,000 | Gal | ||
| 0001 | 103 | Water Collection, Filtration, and Sanitary Sewer Disposal. The average rate of water used is .1 Gal/SF (Total SF x 10%)/ Rinse. | 40,000 | GAL | ||
| 0001 | 104 | Water Containment & Collection System/Linear Foot | 130,000 | LF | ||
| 0001 | 105 | Surface Protection (Other) | 250,000 | SF | ||
| Abatement: | ||||||
| 0001 | 106 | Lead Paint Sampling | 250 | EA | ||
| 0001 | 107 | Lead Contamination Testing Soils | 10 | EA | ||
| 0001 | 108 | Lead Paint Containment and Disposal | 50,000 | SF | ||
| 0001 | 109 | Lead Paint Encapsulation | 10,000 | SF | ||
| 0001 | 110 | Asbestos Sampling | 250 | EA | ||
| 0001 | 111 | Asbestos Abatement Window Putty | 10,000 | SF | ||
| 0001 | 112 | Asbestos Siding Paint/Coating Removal | 1,200 | SF | ||
| 0001 | 113 | Asbestos Encapsulation Sheathing | 2,000 | SF | ||
| 0001 | 114 | Asbestos Removal - Calking and Sealants | 5,000 | LF | ||
| 0001 | 115 | Asbestos/ Mold Containment and Disposal | 100,000 | SF | ||
| 0001 | 116 | TCLP Sampling | 50 | EA | ||
| 0001 | 117 | Toxicity Characteristic Leaching Procedure Review Existing Documents, Surveys and reports. Conduct a good faith survey of, the project. | 25 | EA | ||
| 0001 | 118 | Lead & Asbestos/Mold Work Plan Certified Industrial Hygienist, (CIP) prepare and review of work plan for compliance and worker safety | 50 | EA | ||
| 0001 | 119 | Exposure Assessment Sample and provide reports of worker hazardous exposure for compliance and worker safety | 50 | EA | ||
| 0001 | 120 | Mold remediation air test | 200 | EA | ||
| 0001 | 121 | Pre-cleaning mold contaminated, flat surfaces, HEPA vacuum & wet wipe | 200,000 | SF | ||
| 0001 | 122 | Mold containment with negative air machine | 100 | EA | ||
| 0001 | 123 | Containment area, doff, bag and seal protective sheeting | 150,000 | SF | ||
| Miscellaneous Door & Window Repair: | ||||||
| 0001 | 124 | Remove/Replace Interior Door & Hardware (Labor Only) | 50 | EACH | ||
| 0001 | 125 | Provide Interior Wood Solid Core Door to 3/0x7/0 (Prepped to match existing) Paint Grade | 35 | LEAF | ||
| 0001 | 126 | Provide Interior Wood Hollow Core Door to 3/0x7/0 (Prepped to match existing) Paint Grade | 15 | LEAF | ||
| 0001 | 127 | Remove/Replace Exterior Door & Hardware (Labor Only) | 20 | EACH | ||
| 0001 | 128 | Provide Exterior Wood Solid Core Door to 3/0x7/0 (Prepped to match existing) Paint Grade | 15 | LEAF | ||
| 0001 | 129 | Provide Exterior Insulated Metal Door to 3/0x7/0 (Prepped to match existing) Paint Grade | 5 | LEAF | ||
| 0001 | 130 | Replace window glazing (single pane) | 300 | SF | ||
| 0001 | 131 | Replace window glazing (Insulated Unit) | 100 | SF | ||
| 0001 | 132 | Reputty Window | 1,500 | LF | ||