Attachment - 16 CABINET DIMENSIONAL DATA.pdf

PDF 2 MB Posted

Attached to
Z2DA--EHRM Bonham, TX Construction 549A4-21-700 EHRM Construction (VA-23-00092679)
Solicitation number
36C77624B0007_1
Issued by

About this file

This is a solicitation for construction services for an EHRM facility in Bonham, Texas. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin. Key details include that the solicitation is for construction of a 549A4 facility at the VA Medical Center in Bonham to provide EHRM services. The NAICS code for the opportunity is 238210. Proposals are due by February 12, 2021 and the period of performance is 730 calendar days.

View the file

Other files

File Type Posted
Attachment 56 - Abstract of Bids OF 1419 - CONST-Bonham - Signed.pdf PDF
Attachment 57 - Abstract of Bids OF 1419 A - CONST-Bonham.pdf PDF
36C77624B0007 0012.docx DOCX document
Attachment- 54 Sheet GS020 DETAILS.pdf PDF
Attachment- 53 Sheet GS019 EROSION CONTROL DETAILS.pdf PDF
Attachment- 51 TR Matrix Bonham.pdf PDF
Attachment- 55 Solicitation-RFIs-Tech Responses 36C77624B0007.pdf PDF
Attachment- 52 Hydrology Map.pdf PDF
36C77624B0007 0011.pdf PDF
36C77624B0007 0010.pdf PDF
36C77624B0007 0009.pdf PDF
Att 50 CLARIFICATION of Site Visit-Duct banks not available for use.pdf PDF
36C77624B0007 0008.pdf PDF
36C77624B0007 0007.docx DOCX document
Attachment - 49 S04-sign in sheet-pg 1 Site Visit Bonham TX 1.9.24.pdf PDF
36C77624B0007 0006.docx DOCX document
36C77624B0007 0005.pdf PDF
Attachment - 48 S04-sign in sheet Site Visit Bonham TX 1.9.24.pdf PDF
Attachment - 47 Clarifications-Additional Technical Questions.pdf PDF
36C77624B0007 0004.pdf PDF
Attachment - 46 Answers to Solicitation-RFIs-MISSING SECTION-36C77624B0007_1.pdf PDF
36C77624B0007 0003.pdf PDF
Attachment- 29 Bonham VA - Geotech Rpt 3-30-16-For Soil.pdf PDF
Attachment- 35 01 Bonham EHRM- Narrative.pdf PDF
Attachment- 36 01 Environmental Narrative.pdf PDF
Attachment- 44 Station Pictures for electrical.pdf PDF
Attachment- 28 Bonham EHRM- ICRA Form.pdf PDF
Attachment- 41 07 Electrical Narrative.pdf PDF
Attachment- 30 SPCC-PIPP Plan VANTHCS_Bonham.pdf PDF
Attachment- 38 03 Structural Narrative.pdf PDF
Attachment- 27 Answers to Solicitation-RFIs-36C77624B0007_1.pdf PDF
Attachment- 42 08 Telecom Narrative.pdf PDF
Attachment- 43 09 Security Narrative.pdf PDF
36C77624B0007 0002.pdf PDF
Attachment- 37 02 Civil Narrative.pdf PDF
Attachment- 32 V2 549A4-21-700 100 Bid Document Specifications.pdf PDF
Attachment- 45 IT Closet Proposed lay down.pdf PDF
Attachment- 39 05 Fire Protection Narrative.pdf PDF
Attachment- 34 00 General Narrative.pdf PDF
Attachment- 33 AE Physical Security Risk Mitigation Design Guidance.pdf PDF
Attachment- 31 site plan fiber runs Bonham.pdf PDF
Attachment- 40 06 Mechanical Narrative.pdf PDF
36C77624B0007 0001.pdf PDF
36C77624B0007_1-tech questions date updated.pdf PDF
36C77624B0007_1.pdf PDF
Attachment - 13 Asbestos 3_ VA Checklist_Environ.pdf PDF
Attachment - 03 Civil Drawings_100percent Bid Docs.pdf PDF
Attachment - 24 Limitations on Subcontracting - Construction.pdf PDF
Attachment - 05 Architectural Drawings_100percent Bid Docs.pdf PDF
Attachment - 18 EHRM Bonham - Simulation Main Computer Rm 2 - CFD Analysis.pdf PDF
Show 40 more

Latest 50 of 70 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REV : 7

REV DATE : 5/19

DPN003138

Page :1 /1

DS DOWNFLOW AIR COOLED 53-77kW (15-22 TONS)

W/ SCROLL OR DIGITAL SCROLL COMPRESSOR MODELS

F or m N o.

: D

P N

_R

E V

CABINET DIMENSIONAL DATA

LIEBERT DS

Shaded area indicates a recommended minimum clearance be provided for component access.

FRONT VIEW

76" 1930mm

2" 51mm

Minimum required for filter replacement

34" 864mm

5" 127mm

AIR INLET OPENING

Secondary Entrance High Volt Connection(s)

Secondary Refrigerant Piping Entrance

Secondary Entrance Low Volt ConnectionsTOP VIEW

80" 2032mm Opening

35" 889mm

24 3/8" 619mm Opening

33" 838mm

5/16" 8mm Bezel1 3/4"

44mm Handle

Model No. Air Cooled Dual Cool

DS053 1920 (871) 2100 (953)

DS070 1970 (894) 2150 (975)

DS077 2020 (916) 2200 (998)

Dry Weight (approximate)

lb. (kg)

98" 2489mm

97" 2464mm

Notes:

1. Filters are accessible through top of unit only.

2. Downflow electrical connections can be made from top or bottom of unit.

3. Digital Scroll Compressors not available on 77kW models.

4. Add 120lbs (54kg) for 575V transformer.

5. Secondary Refrigerant piping entrance. Not available with 575V.

6. Unit power must be off when performing transformer and THD filter maintenance.

Shaded area indicates a 24" (610mm) minimum clearance for transformer and THD filter maintenance only.

Document generated 03 March 2021 02:29 PM (EST).

REV : 8

REV DATE : 6/19

DPN002182

Page :1 /1

DOWNFLOW AIR COOLED 53-77kW

SCROLL OR DIGITAL SCROLL COMPRESSOR MODELS W/ EC FANS

F or m N o.

: D

P N

_R

E V

PRIMARY CONNECTION LOCATIONS

LIEBERT DS

L1 L2 G1 G2

O X

Y

98" 2489mm

ECS ECR

CD

POINT DESCRIPTION X in. (mm) Y in. (mm)

R DS REFRIGERANT ACCESS 81-3/4 (2076) 14-3/4 (375)

53kW (15 TONS) 70 & 77kW (20 & 22 TONS)

L1 LIQUID LINE SYSTEM 1 94-11/16 (2405)

L2 LIQUID LINE SYSTEM 2 91-7/8 (2334)

G1 HOT GAS DISCHARGE 1 88-3/4 (2254)

G2 HOT GAS DISCHARGE 2 85-9/16 (2173)

CONDENSATE DRAIN

(infrared humidifier or no humidifier)

W/ OPTIONAL PUMP

HUM HUMIDIFIER SUPPLY LINE 76-1/2 (1943) 29 (737)

ECS ECON-O-COIL SUPPLY 78-5/8 (1997) 22-1/4 (565)

ECR ECON-O-COIL RETURN 73-15/16 (1878) 26-9/16 (675)

E1 78-1/2 (1994)

E2 75-3/8 (1915)

LV1 29 (737)

LV2 30-7/8 (784)

LV3 32 (813)

1/2" O.D. Cu

7/8" O.D. Cu

CONNECTION SIZE / OPENING

12-3/16" (310mm) X 4" (102mm)

5/8" O.D. Cu

1-1/8" O.D. Cu

CD 68-3/8 (1737)

2 (51)

16-3/4 (425)

16-3/8 (416)

31-3/8 (797)

31-1/8 (791)

ELECTRICAL CONN. (LOW VOLT)

ELECTRICAL CONN. (HIGH VOLT)

3/4" NPT FEMALE

1/2" O.D. Cu

1/4" O.D. Cu

2-1/8" O.D. Cu

2-1/2"

7/8"

4 3 3

Front of UnitSection A-A

Notes:

1. Drawing not to scale. All dimensions from rear corner of unit including panels, and have a tolerance of ± 1/2" (13mm).

2. Field pitch Condensate Drain line a minimum of 1/8" (3.2 mm) per foot (305 mm). All units contain a factory installed condensate trap. Do not trap external to the unit.

Select appropriate drain system materials. The drain line must comply with all local codes.

3. Supplied on Dual Cooling systems only.

4. When piping out the top of the unit, install traps in the discharge lines in the bottom of the unit before running lines to the top.

5. Digital Scroll compressor not available on DS077 models.

A A

R

35" 889mm

E1 E2 HUM

LV1

LV2

LV3

EC Fan Outlet

EC Fan Outlet

REV : 2

REV DATE : 5/17

DPN003648

Page :1 /1

DOWNFLOW 53-77kW (15-22 TONS) MODELS

F or m N o.

: D

P N

_R

E V

DISASSEMBLY DIMENSIONAL DATA

LIEBERT DS

33" 838mm

76" 1930mm

A

Compressor Section Assembly Semi-Hermetic shown for reference

FILTER & ELECTRIC BOX ASSEMBLY

BLOWER & COIL ASSEMBLY

Unit w/ Semi-Hermetic Compressor Section

39" 991mm

82" 2083mm

B Assembled Length

37" 940mm

59 7/16" 1510mm

76" 1930mm

Assembled Height

Unit w/ Scroll/Digital Scroll Compressor Section

Notes:

1. Drawing Views are simplified with panels removed to show overall dimensions. See disassembly and handling instructions in installation manual.

2. Semi-Hermetic Compressor options only available on 77kW models.

Air Cooled A/C w / Dual Cool Air Cooled A/C w / Dual Cool Water/Gly col GLYCOOL™/Dual Cool Water/Gly col GLYCOOL™/Dual Cool

Compressor Assembly 970 (441) 970 (441) 540 (246) 540 (246) 1270 (578) 1270 (578) 840 (382) 840 (382)

Filter & Electric Box Assembly 250 (114) 250 (114) 250 (114) 250 (114) 250 (114) 250 (114) 250 (114) 250 (114)

Blow er & Coil Assembly 1230 (560) 1410 (641) 1230 (560) 1410 (641) 1230 (560) 1410 (641) 1230 (560) 1410 (641)

Semi-Hermetic Compressor Scroll or Digital Scroll Compressor Semi-Hermetic Compressor Scroll or Digital Scroll Compressor

APPROXIMATE DRY WEIGHT lb (kg) (Includes Panels)

Assembly

Compressor Ty pe Cooling Ty pe A in. (mm) B in. (mm)

Air Cooled

Air Cooled w / Dual Cool

Water/Gly col

GLYCOOL™/Dual Cool

Air Cooled

Air Cooled w / Dual Cool

Water/Gly col

GLYCOOL™/Dual Cool

15 (381) 97 (2464)

26 (660) 108 (2743)

Scroll or Digital Scroll

Semi-Hermetic 2

2 2

REV : 4

REV DATE : 6/20

DPN003730

Page :1 /1

AIR COOLED SCROLL OR DIGITAL SCROLL COMPRESSOR MODELS

F or m N o.

: D

P N

_R

E V

PIPING SCHEMATIC W/ LIEBERT® MC

LIEBERT® DS

Field installed relief valve(s) required for 50Hz EU CE units rated maximum

480 PSIG (33 Bar).

Check Valve Relief Valve Service

Valve

Head Pressure Control Valve

Service Valve

External Equalizer

Trap at base of risers over 5ft. (1.5m)

Check Valve

LEE-TEMP RECEIVER

HOT GAS DISCHARGE

LIQUID RETURN

EVAPORATOR

COIL

LIQUID

SUCTION

COMPRESSOR

Expansion Valve

Solenoid Valve

Sight Glass

Filter Drier LIQUID LINE

CONDENSER COIL

(Includes factory provided inverted trap. No external trap required)

CONDENSER COIL

(Includes factory provided inverted trap. No external trap required)

For rises over 25ft. (7.6m), trap every 20ft. (6m) or evenly divided

HOT GAS DISCHARGE

FIELD PIPING

FACTORY REFRIGERANT PIPING SERVICE/SCHRADER (ACCESS) CONNECTION NO VALVE CORE

SERVICE/SCHRADER (ACCESS) CONNECTION WITH VALVE CORE

Notes:

1. Single refirigeration circuit shown for clarity.

2. Schematic representation shown. Do not use for specific connection locations.

3. Components are not supplied by Vertiv, but are required for proper operation and maintenance.

4. Traps must be installed and horizontal lines pitched to ensure proper oil return and to reduce liquid floodback to compressor. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

5. Do not isolate any refrigerant circuits from over pressurization protection.

Service Valve

Sensing Bulb

35-42kW digital Solenoid Valve

53-70kW digital Solenoid Valve

OPTIONAL FACTORY PIPING

LIEBERT® MC

LIEBERT® MC WITH LEE-TEMP OPTION

Optional Field Installed Fusible Plug

LIEBERT® DS

INTERCONNECTING

PIPING

Pressure Transducer

Pressure Transducer

REV : 1

REV DATE : 6/18

DPN004352

Page :1 /3

UPFLOW AND DOWNFLOW MODELS

F or m N o.

: D

P N

_R

E V

ELECTRICAL FIELD CONNECTION DESCRIPTION

LIEBERT DS

STANDARD ELECTRICAL CONNECTIONS

1) Primary high voltage entrance - 2.50” (64mm); 1.75” (44mm); 1.375” (35mm) diameter concentric knockouts located in bottom of box

2) Secondary high voltage entrance - 2.50” (64mm); 1.75” (44mm); 1.375” (35mm) diameter concentric knockouts located in top of box

3) Primary low voltage entrance - Quantity (3) 1.375” (35mm) diameter knockouts located in bottom of unit

4) Secondary low voltage entrance - Quantity (3) 1. 375” (35mm) diameter knockouts located in top of box

5) Three phase electrical service - Terminals are on main fuse block (disregard if unit has optional disconnect switch). Three phase service not by Liebert.

6) Earth ground - Terminal for field supplied earth grounding wire. Earth grounding required for Liebert units.

7) Remote unit shutdown - Replace existing jumper between terminals 37 & 38 with field supplied normally closed switch having a minimum 75VA, 24VAC rating. Use field supplied Class 1 wiring.

8) Customer alarm inputs - Terminals for field supplied, normally open contacts, having a minimum 75VA, 24VAC rating, between terminals 24 & 50, 51, 55, 56. Use field supplied Class 1 wiring. Terminal availability varies by unit options.

9) Common alarm - On any alarm, normally open dry contact is closed across terminals 75 & 76 for remote indication. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

10) Heat rejection interlock - On any call for compressor operation, normally open dry contact is closed across terminals 70 & 71(circuit 1), 230 (circuit 2) to heat rejection equipment. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring. When DS unit is paired with a Liebert MC series condenser, remove jumper between terminal 71 and terminal 230. Three wires must connect terminals 70, 71 and 230 of the indoor unit to terminals 70, 71 and 230 of the Liebert MC series condenser.

11) Unit factory installed disconnect switch, Fuse Block and Main Fuses – “Locking Type” consists of a non-automatic molded case switch operational from the outside of the unit. Access to the high voltage electric panel compartment can be obtained only with the switch in the “off” position. Units with fused disconnects are provided with a defeater button that allows access to the electrical panel when power is on. The molded case switch disconnect models contain separate main fuses.

CANBUS ELECTRICAL CONNECTIONS

12) CANbus Connector– Terminal block with terminals 49-1 (CAN-H) and 49-3 (CAN-L) + SH (shield connection). The terminals are used to connect the CANbus communication cable (provided by others) from the indoor unit to the Liebert MC Condenser –Optional Econophase Unit.

13) CANbus Cable – CANbus cable provided by others to connect to the outdoor condenser, and optional PRE unit (DA units only). No special considerations are required when the total external cable connection between the indoor unit and outdoor unit(s) is less than 450FT (137M). For total external cable connections greater than 450FT (137M) but less than 800FT (243M) a CANbus isolator is required.

Contact Factory.

Cable must have the following specifications:

Braided shield or foil shield with drain wire

- Shield must be wired to ground at indoor unit

- 22-18AWG stranded tinned copper

- Twisted pair (minimum 4 twists per foot)

- Low Capacitance (15pF/FT or less)

- Must be rated to meet local codes and conditions

- EXAMPLES BELDEN 89207 (PLENUM RATED), OR ALPHA WIRE 6454 CATEGORY 5, 5E, OR HIGHER

14) Do not run in same conduit, raceway, or chase as high voltage wiring.

15) For CANbus network lengths greater than 450FT (137M) call Factory.

DPN004352

Page :2 /3

UPFLOW AND DOWNFLOW MODELS

F or m N o.

: D

P N

_R

E V

ELECTRICAL FIELD CONNECTION DESCRIPTION

LIEBERT DS

OPTIONAL ELECTRICAL CONNECTIONS

16) Smoke sensor alarm - Factory wired dry contacts from smoke sensor are 91-common, 92-NO, and 93-NC. Supervised contacts, 80 & 81, open on sensor trouble indication. This smoke sensor is not intended to function as, or replace, any room smoke detection system that may be required by local or national codes. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

17) Reheat and humidifier lockout - Remote 24VAC required at terminals 82 & 83 for lockout of reheat and humidifier.

18) Condensate alarm (with condensate pump option) - On pump high water indication, normally open dry contact is closed across terminals 88 & 89 for remote indication. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

19) Remote humidifier - On any call for humidification, normally open dry contact is closed across terminals 11 & 12 to signal field supplied remote humidifier. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

20) Auxiliary cool contact - On any call for econ-o-coil operation, normally open dry contact is closed across terminals 72 & 73 on dual cool units only. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

21) Analog Inputs- Terminals 41, 42, 43, 44 are user configurable for 0-10V, 0-5V, or 4-20MA.

OPTIONAL LOW VOLTAGE TERMINAL PACKAGE CONNECTIONS

22) Remote unit shutdown - Two additional contact pairs available for unit shutdown (labeled as 37B & 38B, 37C & 38C). Replace jumpers with field supplied normally closed switch having a minimum 75VA, 24VAC rating. Use field supplied Class 1 wiring.

23) Common alarm - On any alarm, two additional normally open dry contacts are closed across terminals 94 & 95 and 96 & 97 for remote indication. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

24) Main fan auxiliary switch - On closure of main fan contactor, normally open dry contact is closed across terminals 84 & 85 for remote indication. 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

25) Liqui-Tect shutdown and dry contact - On Liqui-Tect activation, normally open dry contact is closed across terminals 58 & 59 for remote indication (Liqui-Tect sensor ordered separately). 1 AMP, 24VAC max load. Use Class 1 field supplied wiring.

OPTIONAL COMMUNICATION CONNECTIONS

26) Unit-To-Unit – Plug 64 is reserved for U2U communication

27) Site and BMS- Plug 74 and terminal block 3 are reserved for Site and BMS connections. Plug 74 is an eight pin RJ45 for a Cat 5 cable.

Terminal block 3 is a two position screw terminal block for use with twisted pair wires.

NOTE: Refer to specification sheet for total unit full load amps, wire size amps, and max overcurrent protective device size.

DPN004352

Page :3 /3

UPFLOW AND DOWNFLOW MODELS

F or m N o.

: D

P N

_R

E V

ELECTRICAL FIELD CONNECTION DESCRIPTION

LIEBERT DS

75 76 94 95 96 97 91 11 1292 93 80 81

7337C38C37B38B 37 38 24 70 71 23050 51 55 56

888382 89

845958 85 72

434241 44

17 18 9 16 19

20108222425

2 4

A B

C D

A B

C D

P64

OVERCURRENT PROTECTION DEVICES

CONTACTORS

CONTACTORS, RELAYS, &

OVERLOAD PROTECTORS

60 Hz

Risk of broken or shorted low volt wiring. Field installed low volt wiring must be routed with loop as shown to allow electric box to swing.

POINT OF HINGED LOW

VOLT ELECTRIC BOX

DOWNFLOW

LOW VOLT SECTION

UPFLOW LOW VOLT SECTION

3UPFLOW

CAUTION:

S H

-1

-3

Item 12 Installation Conditions

1. Follow all local installation codes.

2. Do not run CAN cables in same conduit, raceway, or chase as high voltage wires (120-600V).

3. Separate high volt wires from CAN wires by 12 inches.

Note: Typical orientation of components shown. Component location varies by option and unit size.

E

E

A B

C D

E

F

P67

P74

TB3

F

F

REV DATE : 3/20

DPN004350

Page :1 /3

UNIT MOUNTED DISPLAY

Fo rm

N o.

: D P

N

_R E

V

PRODUCT INFORMATION

LIEBERT® iCOM™

The Liebert® iCOM™ display is a 7-inch capacitive, color-touchscreen display in an ergonomic, aesthetically pleasing housing. The display and housing will be viewable while the unit accent panels are open or closed.

The display can be easily detached to view while the panel is open.

Menu Layout- The menus will be broken out into two main menu screens: User screen and Service screen.

The User screen contains the menus to access parameters required for basic unit control and setup.

The Service screen is designed for service personal and provides access to advanced control setup features and diagnostic information.

Password Protection- The display will contain two unique passwords to protect against unauthorized changes.

An auto hide/show feature allows the user to see applicable information based on the login used. These four-digit passwords may be customized according to User preference.

Unit Backup and Restore- The user shall have the ability to create safety copies of important control parameters.

The display has the ability for the user to automatically backup unit configuration settings to internal memory or USB storage drive. Configuration settings may be transferred to another unit for a more streamlined unit startup.

Parameter Search- The display has search fields for efficient navigation and parameter lookup.

Parameter Download- The Liebert iCOM shall enable the user to download a report that lists parameter names, factory default settings, and the user programmed settings in .csv format for remote reference.

Parameter Directory- The Liebert iCOM shall provide a directory that lists all parameters in the control. The list shall provide Line ID numbers, parameter labels, and current parameter values.

DPN004350

Page :2 /3

UNIT MOUNTED DISPLAY

Fo rm

N o.

: D P

N

_R E

V

PRODUCT INFORMATION

LIEBERT® iCOM™

Context Sensitive Help- The display will have an onboard help database. The database will provide context sensitive help to assist with setup and navigation of the menus.

Display Setup- The user has the ability to configure the display information based on the specific user’s preference.

Language, units of measure, screen contrast, home screen layout, back light timer and the hide/show of certain readouts will be configurable through the display.

Additional Readouts- The display has the ability for the user to configure custom widgets on the main screen.

Widget options will include items such as fan speed, call for cooling, call for free cooling, maintenance status, call for hot water reheat, call for electric reheat, call for dehumidification, call for humidification, airflow, static pressure, fluid flow rate and cooling capacity.

Status LEDs- The display will provide the user with the unit’s operating status using an integrated LED.

The LED will indicate if the unit has an active alarm; if the unit has an active alarm that has been acknowledged;

or if the unit is on, off, or in a standby status.

Unit Alarms – All unit alarms are annunciated through both audio and visual cues, clearly displayed on the screen, automatically recorded in the event log, and communicated to monitoring plug connections.

Event Log – The display will automatically store the last 400 unit-only events (messages, warnings, and alarms).

Service Contact Information – The display has the ability to store the local service or sales contact information.

Upgradeable –Display and Control Board software upgrades are performed through a USB connection.

Unit-to-Unit (U2U) Communication – Communication via private Ethernet network allows for advanced control functionality (Teamwork modes, sharing sensor data, Standby Rotation, Lead-Lag, and Cascade operation).

Temperature Control- Precision temperature control is maintained while maximizing efficiency based on a user entered setpoint and tolerance.

Various Control Types- Proportional, PI (proportional-integral), or Intelligent control types can be selected for supply or return temperature. These control types have been developed to maximize component life and maintain precise environmental control.

Timers/Sleep Mode- The menus shall allow various customer settings for turning the unit On or Off.

Sensor Calibration- The menus shall allow unit sensors to be calibrated with external sensors.

Maintenance/Wellness Settings- The menus shall allow reporting of potential component problems before they occur.

DPN004350

Page :3 /3

UNIT MOUNTED DISPLAY

Fo rm

N o.

: D P

N

_R E

V

PRODUCT INFORMATION

LIEBERT® iCOM™

Options Setup- The menus shall provide operation settings for the installed components.

Auto Restart- The unit will return to its previous operating status after loss of power. Units can be stagger started to minimize system current draw.

Auxiliary Boards- The menus shall allow setup of optional expansion boards.

Various Sensors: The menus shall allow setup and display of optional custom sensors. The control shall include four customer accessible analog inputs for field-supplied sensors. The analog inputs shall accept a 4 to 20mA signal. The user shall be able to change the input to 0 to 5VDC or 0 to 10VDC. The gains for each analog input shall be programmable from the front display. The analog inputs shall be able to be monitored from the front display.

Diagnostics/Service Mode- The Liebert® iCOM™ control shall be provided with self-diagnostics to aid in troubleshooting. The microcontroller board shall be diagnosed and reported as pass/not pass. Control inputs shall be indicated as On or Off at the front display. Control outputs shall be able to be turned On or Off from the front display without using jumpers or a service terminal. Each control output shall be indicated by an LED on a circuit board.

REV DATE : 2/20

DPN004351

Page :1 /2

F or m N o.

: D

P N

_R

E V

UNIT TO UNIT NETWORK CONNECTIONS

LIEBERT

iCOM™

LIEBERT® CW, LIEBERT® CWA, LIEBERT® DS, LIEBERT® DSE,

LIEBERT® PDX, LIEBERT® PCW

TO / FROM OTHER

NETWORKED UNITS

TB3

P71 P72

P74 P64

E5

P

P

P

P

P

P

P

P

P76

P95

P100

P75

RS485

ETHERNET

SITE AND BMS

COMMUNICATION

CONNECTIONS

iCOM™

MICROPROCESSOR

AND I/O BOARD

ETHERNET CABLE

(FIELD SUPPLIED)

TB3

P

DETAIL A

1 2

A

UNIT-TO-UNIT NETWORKING SWITCH

(FIELD SUPPLIED)

P95 DVI-D CABLE CONNECTION

TO 7-INCH ICOM DISPLAY P100 POWER SUPPLY TO

7-INCH ICOM DISPLAY

DPN004351

Page :2 /2

F or m N o.

: D

P N

_R

E V

UNIT TO UNIT NETWORK CONNECTIONS

LIEBERT

iCOM™

LIEBERT® CW, LIEBERT® CWA, LIEBERT® DS, LIEBERT® DSE,

LIEBERT® PDX, LIEBERT® PCW

ETHERNET CABLE

(FIELD SUPPLIED)

TB3

P71 P72

P74 P64

E5

P

P

P

P

P

P

P

P

P76

P95

P100

P75 iCOM™

MICROPROCESSOR

AND I/O BOARD

TB3

P71 P72

P74 P64

E5

P

P

P

P

P

P

P

P

P76

P95

P100

P75 iCOM™

MICROPROCESSOR

AND I/O BOARD

NOTE* For dual-unit network configurations only

P95 DVI-D CABLE CONNECTION

TO 7-INCH ICOM DISPLAY

P100 POWER SUPPLY TO

7-INCH ICOM DISPLAY

P95 DVI-D CABLE CONNECTION

TO 7-INCH ICOM DISPLAY

P100 POWER SUPPLY TO

7-INCH ICOM DISPLAY

590-1352-501B/SL-31052_REV2_6-17

LIEBERT® LIQUI-TECT® 460 KIT

ZONE LEAK-DETECTION SENSOR WITH CABLE

Product Specification/Installation Guide

The Liebert Liqui-tect 460 (LT460) provides zone detection of leaks, protecting equipment by constantly monitoring the area for leaking liquids.

The LT460 is the ideal solution for perimeter sensing or serpentine coverage of areas requiring up to 100 ft of cable.

Selectable modes of operation provide flexible alarming options and protection for the cable. The LT460 constantly monitors a zone for leaks, internal faults, and power failures and warns of any abnormal conditions. Top-cover LEDs provide status indication and also ensure that the cable is properly installed and operational under raised floors.

Two independent outputs provide a signal to a local alarm panel, Liebert environmental unit, remote building-management system, or external equipment, such as motorized water shut-off valves.

LT460 APPLICATIONS

The LT460 is ideally-suited for:

• Glycol and chilled-water cooling,

• Humidification supply water piping,

• Condensate pumps and drains,

• Unit and ceiling auxillary drip pans,

• Overhead piping troughs.

LOCATIONS/PLACEMENT

The LT460 is an excellent choice for:

• Large-scale network control centers,

• Data centers,

• MRI and CAT-scan rooms

• Server rooms and closets,

• Unattended, remote shelters,

• Mechanical equipment rooms,

• Sensitive areas with overhead piping,

• Industrial process-control rooms.

COMPONENTS

Liqui-tect 460 Module The LT460 consists of a metal enclosure with a hinged top door providing access to the internal circuit board for wiring termination and configuration of DIP switches. The LT460 will monitor up to 100 feet of connected LT500Y leak detection cable.

LT500Y Leak Detection Cable The cable material and construction allow the cable to lie flat when used with hold-down clips. The LT500Y is plenum-rated and UL-listed for safe operation.

• If purchased separately, cables are available in lengths of 15, 35 and 50 feet. These cables can be connected incrementally to monitor from 15 feet up to 100 feet. An end terminator and hold-down clips (two clips required for each 6-8 ft. of cable) must be ordered separately.

• If included in a kit, cables are available in lengths of 20, 25, 30, 35 and 45 feet. Cables in kits cannot be lengthened. Hold-down clips are provided.

LIEBERT® LT460 ZONE LEAK-DETECTION SENSOR

Product Specification/Installation Guide

SPECIFICATIONS

Power Requirements 24 VAC 120 mA, 50/60 Hz, 3 VA (max.)

Dimensions, W x D x H 5.35 x 3.23 x 3.5 in. (135.9 mm x 82 mm x 88.9 mm) Mounting-holes require #8 screws.

Weight (assembled) 2.0 lb (0.9 kg)

Leak-detection Cable Compatibility All Liebert LT500 sensing cables

Maximum Leak-detection Cable Length 100 ft (30.5 m)

Metal Enclosure NEMA 1, IP 30

ENVIRONMENTAL CONDITIONS

Operating Temperature 50°F to 104°F (10°C to 40°C)

Operating Humidity 10% to 95% relative humidity (non-condensing)

Operating Altitude 0 to 10,000 ft (0 to 3,048 m)

Output Relay Contact Rating 2 Form-C; 3 A rating at 24 VAC

AGENCY LISTINGS

UL UL916

C-UL C22.2, No. 205-M1983

CE Yes

FCC Compliance 47 CFR, Part 15

TOP VIEW FRONT VIEW SIDE VIEW

4.75” (121 mm)

3.25” (83 mm)

Form-C relay outputs and power wiring

DIMENSIONS -

TOP, FRONT AND SIDE

Leak detection cable connector

4.25” (108 mm)

2.00” (51 mm)

LIEBERT® LT460 ZONE LEAK-DETECTION SENSOR

Product Specification/Installation Guide

CONFIGURATION-SWITCH SETTINGS

A 4-position DIP switch selects two alarm (filter) delays and three mutually-exclusive alarm modes. The switches are located next to the wiring termination blocks.

PLACEMENT ON SUBFLOOR

UNDER COOLING SUPPORT

EQUIPMENT

To a Liebert environmental unit and an optional monitoring

To external power supply or directly from unit

Leak detection zone (directly beneath unit)

Leak detection cable

LT460

To a Liebert environmental unit and an optional monitoring

To a Liebert environmental unit and an optional monitoring

TB3-3

TB3-2

TB3-1

N.C.

N.O.

C

N.C.

N.O.

C

TB2-3

TB2-2

TB2-1

TB1-2

TB1-1

Contacts Rating:

24V, 3A

Contacts Rating:

24V, 3A

24V~ 50/60Hz 0.12A

SWITCH SETTINGS

1. Leak Detect Filter

2. Alarm Latch

3. Alarm Retest Delay

4. Not Used

0FF ON

10 sec 2 min No Yes No 1 hr

ALL CIRCUITS: CLASS 2

Contacts shown in POWERED, NON-ALARM state

CONNECT ENCLOSURE TO EARTH GROUND

VertivCo.com | Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA © 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.

590-1352-501B/SL-31052_REV2_6-17

LIEBERT® LT460 ZONE LEAK-DETECTION SENSOR

Product Specification/Installation Guide

POWER WIRING

The LT460 is rated for 24 VAC, 50/60 Hz, and 0.12 A.

Liebert DS, DSE, CW, PDX, or Mini-Mate2 (8 ton) LT460

TB1 TB1

T5 (24V) Red

G5 (Ground) Red

Location of T5 (24V) connection on main controller board of Liebert unit.

Liebert Mini-Mate2 LT460 (1 to 5 ton)

TB1

From 24V Transformer Red

Red

* Requires external transformer (there are no designated terminal connections on the unit)

Liebert CRV LT460

Medium Control Board TB1

6 Red

4 Red

Transformer LT460

TB1

From 24V Transformer Red

Red

WIRING TO AUXILIARY ALARM PANELS

The LT460 has two Form-C dry-contact alarm-output contacts (TB2 and TB3). Each contact is rated for 24 VAC at 3 amp..

Liebert DS, DSE, LT460 CW, PDX or Mini-Mate2 (8 ton) Orange Wires Environmental

TB2-3 (N.C)

Unit

TB2-2 (C) 24 (24V)

TB2-1 (N.O.) 50, 51, 55 or 56

Note: Terminal 50 not available on Mini-Mate2 (8-ton)

Liebert Mini-Mate2, LT460 (1 to 5 ton) Orange Wires Environmental

TB2-3 (N.C)

Unit

TB2 (C) TB1-1 (24V)

TB2-1 (N.O.) TB1-2 or TB1-3

LT460 Liebert CRV Orange Wires Environmental

Unit

TB2-2 (C) 60

TB2-1 (N.O.) 61

NOTE: In iCOM, use the Service Options menu to add that the Liqui-tect is installed.

LT460 Liebert contact monitor panel TB2 Alarm

Panel

TB2-2 (C)

TB2-1 (N.O.)

TB1

Input contact (N.O.)

REV DATE : 8/19

DPN002155

Page :1 /1

STANDARD & OPTIONAL FEATURES

F or m N o.

: D

P N

_R

E V

PREMIUM EFFICIENCY CONTROL

LIEBERT MC CONDENSER

STANDARD FEATURES

COIL Liebert microchannel coils are all‐aluminum construction. Tubes are created by extruding small parallel refrigerant flow paths into aluminum.

Full‐depth louvered aluminum fins fill spaces between the tubes. Tubes, fins and aluminum headers are oven‐brazed to form a complete refrigerant‐to‐air heat exchange coil. Baffles are used in the headers to separate one coil slab into multiple passes as needed. Coils are factory leak tested at a minimum of 300 PSIG and dehydrated. Copper stub pipes are electric resistance welded to aluminum coils and joints are protected with polyolefin to seal joint from environmental corrosive elements. Hot gas and liquid lines are brazed to the stub pipes with spun closed ends for customer piping connections. Coil pipe assembles are filled and sealed with a nitrogen holding charge for shipment. One coil is used per fan assembly.

FAN/MOTOR ASSEMBLY The fan/motor assembly is complete with external rotor motor, fan blades and fan/finger guard. Fan blades are constructed of stamped aluminum or steel extrusion coated with PP plastic. Fan guards are heavy gauge, close meshed, steel wire, coated with a black corrosion resistant finish. Fan terminal blocks located on the top of the fan guard with IP54 protection class. Fans are factory balanced and tested before shipment.

FAN MOTORS Fan motors are specifically designed for variable speed and have ball bearings. The EC fans provide internal overload protection through the built‐in electronics. Each EC fan motor has built‐in controller and communication module, linked via RS485 communication wire to each fan and the Premium Control Board. This allows each fan to receive and respond to precise fan speed inputs from the Premium control board.

PREMIUM EFFICIENCY FAN CONTROL The Liebert premium efficiency condenser control system is complete with control board, EC fan motor(s),refrigerant‐pressure transducer(s), refrigerant‐temperature thermistor(s), ambient‐temperature thermistor, and motor overload protection in the factory wired control panel. The control board maintains EC fans on the same circuit to the same speed in order to maintain refrigerant head pressure. The control board receives a run signal from the compressor of the indoor unit via field‐supplied low voltage interlock wires and field‐supplied CANbus communication wires from the indoor unit iCOM. The control system provides refrigerant head pressure and system starting for outdoor ambient temperature as low as -30°F (‐35 °C), provided the total temperature design range (from minimum to maximum) is 125°F (70°C) or less.

HOUSING The condenser housing is constructed of bright aluminum sheet and divided into individual fan sections by full width baffles. Internal structural support members, including coil support frame, are galvanized steel for strength and corrosion resistance. Panel doors are provided on two sides of each coil/fan section to provide for coil cleaning. Aluminum legs are provided with rigging holes for hoisting the unit into position.

COMMUNICATION The Premium Efficiency Control communicates with the iCOM control of the indoor Liebert unit using field supplied CANbus wires. The communication link allows for condenser alarm condition communication to iCOM, communication of other measurable items on the condenser, and fan control features to improve efficiency, sound and wintertime operation based on iCOM programming.

UNIT DISCONNECT SWITCH Locking unit disconnect switch is factory installed and wired in attached condenser control section.

OPTIONAL FEATURES

LIEBERT LEE‐TEMP LOW AMBIENT CONTROL Lee‐Temp receiver kits can be added to achieve head pressure control down to minimum ambient temperatures of ‐30 °F (‐34 °C). The premium efficiency fan control when used with the Liebert Lee‐Temp receiver kits runs the fan(s) at lower speeds during cold temperatures saving fan energy.

575V POWER SUPPLY The factory installed condenser option will include a secondary enclosure, a 575V-to-480V, 3 phase, step down transformer, secondary fuses for the transformer, and all wiring between the main and secondary electrical enclosures. Site power connections will be made in the main electrical enclosure and the secondary enclosure will be located on the condenser end opposite of the main electrical enclosure.

E-COAT COIL PROTECTION The aluminum microchannel coil is epoxy-coated for extended coil life in corrosive environments, such as coastal areas.

Factory-applied E-coat using immersion and baking process provides a flexible epoxy-coating to all coil surfaces and ensures complete coil encapsulation. Coil color is black and a factory-applied UV topcoat protects the E-coat from solar UV ray degradation.

REV DATE : 12/16

DPN003437

Page :1 /1

2 FAN (MCS056, MCM080, MCL110) DUAL CIRCUIT

F or m N o.

: D

P N

_R

E V

CABINET & ANCHOR DIMENSIONAL DATA

LIEBERT MC CONDENSER

Lee-Temp or DSE Receiver

A A* F

Typical All Legs

DIM "G" 31-5/8 (803) 49-5/8 (1260) 61-5/8 (1565) 73-5/8 (1870)

DIM "H" 39-5/8 (1006) 57-5/8 (1464) 69-5/8 (1768) 81-5/8 (2073)

MCL110

DIM "G" 35-7/8 (911) 53-7/8 (1368) 65-7/8 (1673) 77-7/8 (1978)

DIM "H" 43-5/8 (1108) 61-5/8 (1565) 73-5/8 (1870) 85-5/8 (2175)

LIEBERT

MODEL

NUMBER

MCS056

MCM080

F

(LEG HEIGHT DIMENSIONS)

18 (457) 36 (914) 48 (1219) 60 (1524)

Note:

1. Liebert recommends a clearance of 36” (915mm) on each side for proper operation and component access.

Cross bracing required for legs longer than 18" (457mm). Quantity varies per model & options selected.

For DSE models only, 6-1/2" (165mm) dimension is 9-1/4" (235mm) and 15-1/4 (387mm) dimension is not applicable.

G

H

TOP OF

FAN GUARD

Left Side of Unit

C D

J Lee-Temp or DSE Only

K L M

Anchor Plan

Front View (Lee-Temp Shown)

K Dual Circuit Only

A

DETAIL A

1 7/8" 48mm Typ.

3 5/8" 93mm Typ.13/16"

21mm Typ.

7" 178mm

Typ.

575V Option

Entering Hot Gas and Leaving Liquid Piping

Full height leg supplied for each Lee-Temp or

DSE Receiver required

MCS056 94-7/8 (2411) 103-1/8 (2619) 88-3/8 (2245) 86-3/4 (2203) 42-1/2 (1079) 42-1/2 (1080) 40-7/8 (1038) 35-7/8 (910)

MCM080 105-1/4 (2674) 113-7/16 (2882) 96-1/16 (2440) 94-7/16 (2398) 46-5/16 (1177) 46 (1168) 44-3/8 (1127) 39-5/16 (999)

MCL110 124-1/8 (3152) 133-1/8 (3381) 112-1/8 (2848) 110-1/2 (2806) 54-3/8 (1381) 55-1/2 (1410) 53-7/8 (1368) 48-3/4 (1238)

J

Lee-Temp or

DSE Receivers

Only

K L MDC

LIEBERT

MODEL

NUMBER

A A*

(575V ONLY)

Main Electric

Box End

6 1/2" 165mm Ref.

6 1/2" 165mm Ref.

All primary dimensions in tables are in inches (Secondary are in mm) except where specified

575V Option

15 1/4" 387mm

15 1/4" 387mm

Dual Circuit Only

1/2" (13mm) X 1" (25mm) Obround Typ.

REV DATE : 4/18

DPN003034

Page :1 /1

F or m N o.

: D

P N

_R

E V

CONDENSER AND OPTION WEIGHT DATA, lb(kg)

LIEBERT MC CONDENSER

Total weight is the sum of 'Condenser' + ('PDX-EEV Receiver' or 'Lee-Temp' or 'DSE Receiver 050/080/085' or 'DSE Receiver

125/150/165')'+'Coated Coil' + '575V Transformer'.+ 'Seismic/Wind Bracing'

MCS028 MCS056 MCM040 MCM160

1 2 1 1 2 2

18" Leg 154 ( 70) 270 ( 122) 231 ( 105) 441 ( 200) 441 ( 200) 860 ( 390)

36" Leg 286 ( 130) 419 ( 190) 363 ( 165) 590 ( 268) 590 ( 268) 1066 ( 484)

48" Leg 318 ( 144) 451 ( 205) 395 ( 179) 622 ( 282) 622 ( 282) 1114 ( 505)

60" Leg 349 ( 158) 482 ( 219) 426 ( 193) 653 ( 296) 653 ( 296) 1160 ( 526)

45 ( 20) 45 ( 20) 45 ( 20)

55 ( 25) 110 ( 50) 55 ( 25) 100 ( 45) 110 ( 50) 220 ( 100)

45 (20) 90 (41)

92 (42) 184 ( 83)

55 ( 25) 65 ( 29) 60 ( 27) 70 ( 32) 70 ( 32) 80 ( 36)

4 ( 2) 8 ( 4) 5 ( 2) 10 ( 5) 10 ( 5) 20 ( 9)

40 ( 18) 40 ( 18) 40 ( 18) 40 ( 18) 40 ( 18) 57 ( 26)

Additional Weight for Options

Refrigerant Circuits

Size Small (MCS) Medium (MCM)

MCM080Condenser Model

PDX-EEV Receiver

Condenser Dry

Weight

Lee-Temp

DSE Receiver DA050/080/085

DSE Receiver DA125/150/165

Seismic/Wind Bracing 18" legs

Coated Coil

575V Transformer

MCL055 MCL165

1 1 2 1 1 2

18" Leg 344 ( 156) 602 ( 273) 602 ( 273) 891 ( 404) 1186 ( 538) 1186 ( 538)

36" Leg 486 ( 220) 766 ( 347) 766 ( 347) 1136 ( 515) 1453 ( 659) 1453 ( 659)

48" Leg 518 ( 235) 798 ( 362) 798 ( 362) 1184 ( 537) 1501 ( 681) 1501 ( 681)

60" Leg 549 ( 249) 829 ( 376) 829 ( 376) 1230 ( 558) 1547 ( 702) 1547 ( 702)

45 ( 20)

60 ( 27) 115 ( 52) 120 ( 54) 175 ( 79) 215 ( 98) 240 ( 109)

45 ( 20) 90 ( 41) 45 (20) 45 ( 20) 90 ( 41)

94 ( 43) 94 ( 43) 94 ( 43) 188 ( 85)

67 ( 30) 77 ( 35) 77 ( 35) 118 ( 54) 118 ( 54) 118 ( 54)

8 ( 4) 16 ( 7) 16 ( 7) 24 ( 11) 32 ( 15) 32 ( 15)

40 ( 18) 40 ( 18) 41 ( 19) 57 ( 26) 57 ( 26) 57 ( 26)

575V Transformer

Coated Coil

Seismic/Wind Bracing 18" legs

Size Large (MCL)

Condenser Model MCL110 MCL220

Refrigerant Circuits

Condenser Dry weight

PDX-EEV Receiver

Lee-Temp

DSE Receiver DA050/080/085

DSE Receiver DA125/150/165

Additional Weight for Options

REV : 6

REV DATE : 12/16

DPN002425

Page :1 /1

DUAL CIRCUIT 2 FAN & 4 FAN UNITS

Fo rm

N o.

: D P

N

_R E

V

PIPING DIMENSIONAL DATA

LIEBERT MC CONDENSER

(VERTICAL POSITION IS PREFERRED,

HORIZONTAL POSITION IS OPTIONAL.)

FOR TWO CIRCUIT SYSTEMS, ONE

FUSIBLE PLUG KIT WILL NEED TO

BE INSTALLED IN EACH CIRCUIT. A

DETAIL A

VERTICAL

HORIZONTAL

LEAVING LIQUID

LINE

FIELD PIPING

ENTERING HOT

GAS LINE

CIRCUIT #1 CIRCUIT #2

COVER *

* SHIPPING COVER IS NOT NECESSARY FOR PROPER CONDENSER OPERATION AND

MAY BE RECYCLED IF FIELD PIPING INTERFERES WITH PROPER REATTACHMENT.

HOT GAS LINE LIQUID LINE

MCS 056 2 2 7/8 5/8

MCM 080 2 2 7/8 5/8

MCL 110 2 2 1-1/8 7/8

MCM 160 4 2 1-1/8 7/8

MCL 220 4 2 1-3/8 1-1/8

CONDENSER

CIRCUITS

CONNECTION SIZES ,OD,IN

MODEL NO.

NUMBER

OF FANS

INVERTED TRAPS

ARE FACTORY PROVIDED

INSIDE CONDENSER

OPTIONAL FUSIBLE PLUG SERVICE KIT TO

BE BRAZED INTO THE LIQUID LINE(S) IN

EITHER THE VERTICAL OR HORIZONTAL

POSITION (WHERE REQUIRED).

REV : 14

DPN000788

Page :1 /2

F or m N o.

: D

P N

_R

E V

RECOMMENDED REFRIGERANT LINE SIZES CU, OD

LIEBERT AIR COOLED SYSTEMS

Indoor Model Equivalent Length 50 ft (15m) 100 ft (30m) 150 ft (45m) 300 ft (91m) 450ft (137m)

Hot Gas Line, in. 3/4 3/4 3/4 7/8

Liquid Line, in. 5/8 5/8 5/8 3/4

Hot Gas Line, in. 7/8 7/8 7/8 1-1/8

Liquid Line, in. 3/4 3/4 3/4 7/8

Hot Gas Line, in. 1/2 5/8 5/8 5/8

Liquid Line, in. 3/8 1/2 1/2 1/2

Hot Gas Line, in. 5/8 5/8 5/8 3/4

Liquid Line, in. 1/2 1/2 1/2 5/8

Hot Gas Line, in. 3/4 3/4 3/4 7/8

Liquid Line, in. 5/8 5/8 5/8 5/8

Hot Gas Line, in. 7/8 7/8 7/8 1-1/8

Liquid Line, in. 5/8 5/8 5/8 3/4

Hot Gas Line, in. 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

Liquid Line, in. 7/8 7/8 7/8 7/8 7/8

Hot Gas Line, in. 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8

Liquid Line, in. 7/8 7/8 7/8 7/8 7/8

Hot Gas Line, in. 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8

Liquid Line, in. 7/8 1-1/8 1-1/8 1-1/8 1-1/8

Hot Gas Line, in. 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8

Liquid Line, in. 7/8 1-1/8 1-1/8 1-1/8 1-1/8

Hot Gas Line, in. 1-5/8 1-5/8 1-5/8 1-5/8

Liquid Line, in. 1-3/8 1-3/8 1-3/8 1-3/8

DA165

System Fluid : R-410A

CR035RA

PX018

PX023

PX029

DA050 / DA080/

DA085

Any Compressor Type

CR019RA/ CR020RA

DA125

DA150

PX011

DA250 / DA265

LIEBERT AIR-COOLED SYSTEMS USING R-410A

Notes:

1. Consult factory for proper line sizing for runs longer than maximum equivalent length shown in table.

2. Must downsize vertical riser one trade size (1-1/8” to 7/8” or 7/8” to 3/4” or 3/4" to 5/8" or 5/8" to 1/2").

3. Consult factory when actual pipe length between condenser/Liebert EconoPhase and Liebert DSE unit will exceed 300 ft (91 m).

4. Liebert DA250-265 unit can be extended to max 200ft (61m) linear or 300ft. (91m) equivalent.

Indoor Model Equivalent Length 50 ft (15m) 75 ft (23m) 100 ft (30m) 125 ft (38m) 150 ft (45m)

Suction Line, in. 7/8 7/8 7/8 7/8 7/8

Liquid Line, in. 1/2 1/2 1/2 1/2 1/2

Suction Line, in. 7/8 1-1/8 1-1/8 1-1/8 1-1/8

Liquid Line, in. 1/2 1/2 5/8 5/8 5/8

Suction Line, in. 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

Liquid Line, in. 1/2 5/8 5/8 5/8 5/8

System Fluid: R-410A Digital Scroll Models

MT060

MT048

MT036

2 2 2

2 2 2 2

REV : 14

DPN000788

Page :2 /2

F or m N o.

: D

P N

_R

E V

RECOMMENDED REFRIGERANT LINE SIZES CU, OD

LIEBERT AIR COOLED SYSTEMS

Indoor Model Equivalent Length 50 ft (15m) 100 ft (30m) 150 ft (45m) 200 ft (60m) 50 ft (15m) 100 ft (30m) 150 ft (45 m)

Hot Gas Line, in. 7/8 7/8 7/8 3/4 7/8 7/8

Liquid Line, in. 1/2 5/8 5/8 1/2 5/8 5/8

Hot Gas Line, in. 7/8 7/8 7/8 7/8 7/8 1-1/8

Liquid Line, in. 1/2 5/8 5/8 5/8 5/8 5/8

Hot Gas Line, in. 7/8 1-1/8 1-1/8 7/8 1-1/8

1-1/8

Liquid Line, in. 5/8 7/8 7/8 5/8 7/8 7/8

Hot Gas Line, in. 1-1/8 1-1/8 1-1/8 1-1/8

1-1/8

1-1/8

Liquid Line, in. 7/8 7/8 7/8 7/8 7/8 7/8

Hot Gas Line, in. 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8 1-1/8

Liquid Line, in. 7/8 7/8 7/8 7/8 7/8 7/8

Hot Gas Line, in. 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8

Liquid Line, in. 7/8 7/8 1-1/8 7/8 7/8 1-1/8

Hot Gas Line, in. 1-1/8

1-1/8

1-3/8

1-3/8

Liquid Line, in. 7/8 1-1/8 1-1/8 1-1/8

XDC160

DS070

DS077

DS053

DS105

DS042

System Fluid : R-407C Standard Scroll Models (Non-Digital Scroll) 4-Step Semi-Hermetic or Digital Scroll Models

DS035

Indoor Model Equivalent Length 50 ft (15m) 75 (23m) 100 ft (30m) 125 (38m) 150 ft (45m)

Suction Line, in. 5/8 5/8 7/8 7/8 7/8

Liquid Line, in. 3/8 3/8 3/8 3/8 3/8

Suction Line, in. 5/8 7/8 7/8 7/8 7/8

Liquid Line, in. 3/8 3/8 3/8 1/2 1/2

Suction Line, in. 7/8 7/8 7/8 7/8 7/8

Liquid Line, in. 3/8 3/8 1/2 1/2 1/2

Suction Line, in. 7/8 7/8 1-1/8

1-1/8

1-1/8

Liquid Line, in. 1/2 1/2 1/2 1/2 1/2

Suction Line, in. 1-1/8 1-1/8 1-1/8 1-3/8 1-3/8

Liquid Line, in. 1/2 5/8 5/8 5/8 5/8

MMD36/ MMD35 / DME037 /

MMD96-3T / MMD95-3T

MMD60/ MMD59 / MMD96-5T

/MMD95-5T

System Fluid : R-407C Standard Scroll Models (Non-Digital Scroll)

MMD12

MMD18 / DME020

MMD24 / DME027

LIEBERT AIR-COOLED SYSTEMS USING R-407C

Note:

1. Consult factory for proper line sizing for runs longer than maximum equivalent length shown in tables above.

2. Downsize vertical riser one trade size (1-1/8" to 7/8").

3. Digital scroll not available on 077 and 105 models.

4. Double risers are required when hot gas vertical rise is 15 ft (4.6m) or more. Refer to Liebert XDC user manual®

REV : 7

REV DATE : 12/17

DPN002188

Page :1 /1

F or m N o.

: D

P N

_R

E V

TYPICAL PIPING SCHEMATIC FOR AIR-COOLED DX SYSTEMS

LIEBERT MC CONDENSER

Field installed relief valve(s) required for 50Hz EU CE units.

Check Valve Relief Valve Service

Valve Head Pressure Control Valve

Service Valve

External Equalizer

Trap at base of risers over 5ft. (1.5m)

Check Valve

LEE-TEMP RECEIVER

HOT GAS DISCHARGE

LIQUID RETURN

EVAPORATOR

COIL

LIQUID

SUCTION

COMPRESSOR

Expansion Valve

Solenoid Valve

Sight Glass

Filter Drier LIQUID LINE

Check Valve

CONDENSER COIL

(Includes factory provided inverted trap. No external trap required)

CONDENSER COIL

(Includes factory provided inverted trap. No external trap required)

For rises over 25ft. (7.6m), trap every 20ft. (6m) or evenly divided

HOT GAS DISCHARGE

FIELD PIPING

FACTORY REFRIGERANT PIPING SERVICE/SCHRADER (ACCESS) CONNECTION NO VALVE CORE

SERVICE/SCHRADER (ACCESS) CONNECTION WITH VALVE CORE

Notes:

1. Single refrigeration circuit shown for clarity.

2. Schematic representation shown. Do not use for specific connection locations.

3. Components are not supplied by Liebert, but are required for proper operation and maintenance.

4. Traps must be installed and horizontal lines pitched to ensure proper oil return and to reduce liquid floodback to compressor. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

5. Do not islolate any refrigeration circuits from over pressurization protection.

Service Valve

Sensing Bulb

LIEBERT MC CONDENSER

LIEBERT MC CONDENSER WITH LEE-TEMP OPTION

Pressure Transducer

Pressure Transducer

INTERCONNECTING

PIPING

Optional Field Installed Fusible Plug

REV DATE : 9/19

DPN003954

Page :1/4

LIEBERT MC CONDENSER

F or m N o.

: D

P N

_R

E V

AIR COOLED PIPING SCHEMATIC

Indoor Unit

Notes:

1. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

2. Single circuit condenser shown.

3. Unit piping entrance varies by unit and may be through the top of the unit.

4. Indoor unit may be Liebert DS, PDX, or CRV and is shown for reference only while demonstrating proper pipe and unit/condenser height differences.

5. The bottom of the condenser coil or bottom of the receiver (if equipped) must be higher than the elevation of the TXV inside the indoor unit. The vertical height must not exceed 60 feet (18.3m).

6. Trapping must be practiced at bottom of riser with any rise over 5 feet high. If rise exceeds 25 feet (7.5m), then a trap is required in 20 foot (6 m) increments or evenly divided

Field piping

Gas

Gas

Liquid

Liquid

Gas

MC Condenser without Receiver

Liquid

Gas

CONDENSER ABOVE INDOOR UNIT

Liquid

MC Condenser with Receiver

H

60' 18.3m

Maximum Vertical Rise

7.6" 194mm

Internal TXV Height H in. (mm)

PDX Downflow 44 (1118)

PDX Upflow 20 (508)

DS035-105 Downflow/Upflow 43 (1092)

CRV - CR019 45 (1143)

CRV - CR020/CR035 27 (686)

TXV location

(Piping to Condenser & Receiver not shown for clarity)

(Piping to Condenser not shown for clarity)

DPN003954

Page :2/4

LIEBERT MC CONDENSER

F or m N o.

: D

P N

_R

E V

AIR COOLED PIPING SCHEMATIC

Indoor Unit

Notes:

1. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

2. Single circuit condenser shown.

3. Unit piping entrance varies by unit and may be through the top of the unit.

4. Indoor unit may be Liebert DS, PDX, or CRV and is shown for reference only.

5. The bottom of the receiver must be higher than the elevation of the TXV inside the indoor unit, otherwise extended legs or a field piped subcooler needs to be utilized. Contact your Vertiv sales representative for additional information.

Gas

CONDENSER AND INDOOR UNIT AT SAME LEVEL

3MC Condenser with Receiver (complete piping not shown for clarity)

H

TXV location

Internal TXV Height H in. (mm)

PDX Downflow 44 (1118)

PDX Upflow 20 (508)

DS035-105 Downflow/Upflow 43 (1092)

CRV - CR019 45 (1143)

CRV - CR020/CR035 27 (686)

DPN003954

Page :3/4

LIEBERT MC CONDENSER

F or m N o.

: D

P N

_R

E V

AIR COOLED PIPING SCHEMATIC

Indoor Unit

H

TXV location

Liquid

Gas

CONDENSER AND INDOOR UNIT AT SAME LEVEL

Notes:

1. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

2. Single circuit condenser shown.

3. Unit piping entrance varies by unit and may be through the top of the unit.

4. Indoor unit may be Liebert DS, PDX, or CRV and is shown for reference only.

5. The bottom of the coil must be less than 15' (4.6m) below the elevation of the TXV inside the indoor unit.

Contact your Vertiv sales representative for additional information.

PDX Downflow 44 (1118)

PDX Upflow 20 (508)

DS035-105 Downflow/Upflow 43 (1092)

CRV - CR019 45 (1143)

CRV - CR020/CR035 27 (686)

MC Condenser without Receiver

DPN003954

Page :4/4

LIEBERT MC CONDENSER

F or m N o.

: D

P N

_R

E V

AIR COOLED PIPING SCHEMATIC

Notes:

1. Pitch horizontal hot gas piping at a minimum of 1/2" per 10 feet (42mm per 10m) so that gravity will aid in moving oil in the direction of the refrigeration flow.

2. Single circuit condenser shown.

3. Unit piping entrance varies by unit and may be through the top of the unit.

4. Indoor unit may be Liebert DS, PDX, or CRV and is shown for reference only while demonstrating proper pipe and unit/condenser height differences.

5. The bottom of the condenser coil must be less than 15 feet (4.6m) below the location of the TXV in the indoor unit, otherwise extended legs or a field piped subcooler needs to be utilized.

Contact your Vertiv sales representative for additional information.

6. This Configuration is not valid for Liebert MC with Lee-Temp or unheated receiver.

Indoor Unit

Field piping

Gas

Liquid

MC Condenser without receiver

CONDENSER BELOW INDOOR UNIT

Gas

Gas

MC Condenser with Receiver 6

H

15' 4.6m

Maximum Vertical Drop

TXV location5

PDX Downflow 44 (1118)

PDX Upflow 20 (508)

DS035-105 Downflow/Upflow 43 (1092)

CRV - CR019 45 (1143)

CRV - CR020/CR035 27 (686)

REV : 10

REV DATE : 2/17

DPN002169

Page :1 /3

PREMIUM EFFICIENCY CONTROL

F or m N o.

: D

P N

_R

E V

ELECTRICAL FIELD CONNECTIONS

LIEBERT MC CONDENSER

FAN 2

FAN 1

SH

NOTICE !

THIS HOLE FOR FIELD

SUPPLIED EXTRA LOW

VOLTAGE CONTROL WIRING

KEY ELECTRICAL DETAILS:

1) Three phase electrical service – Terminals are on top of disconnect switch for one and two fan units. Terminals are on bottom of disconnect switch for three and four fan units. Three phase service not by Liebert. See note 5.

2) Earth ground – Field lug terminal for earth ground connection. Ground terminal strip for fan motor ground connection.

3) Primary high voltage entrance – Two 7/8” (22.2mm) diameter knockouts located at the bottom of the enclosure.

4) SPD field connection terminals – High voltage surge protective device (SPD) terminals. SPD is an optional device.

DPN002169

Page :2 /3

PREMIUM EFFICIENCY CONTROL

F or m N o.

: D

P N

_R

E V

ELECTRICAL FIELD CONNECTIONS

LIEBERT MC CONDENSER

5) CANbus terminal connections – Field terminals for CANbus cable connection.

• 5A is the CANbus connectors.

o TB49-1 is the input terminal for CANbus high.

o TB49-3 is the input terminal for CANbus low.

o TB50-1 is output terminal for CANbus high.

o TB50-3 is the output terminal for CANbus low.

o Each CANbus cable shield is connected to terminal “SH”, item 9.

• 5B is the “END OF LINE” jumper.

• 5C is the CANbus “DEVICE ADDRESS DIP SWITCH”. CANbus cable not by Liebert. See Note 2. (below)

6) Remote unit shutdown – Replace existing jumper between terminals TB38-1 and TB38-2 with field supplied normally closed switch having a minimum 75VA 24VAC rating. Use field supplied Class 1 wiring. (This is an optional feature that may be owner specified.)

7) Alarm terminal connections –

a. Common Alarm Relay indicates when any type of alarm occurs. TB74-1 is common, TB74-2 is normally open, and TB74-3 is normally closed. 1 Amp 24VAC is the maximum load. Use Class 1 field supplied wiring.

b. Shutdown Alarm Relay indicates when condenser loses power, or when a critical alarm has occurred that shuts down the condenser unit. TB74-4 is common, TB74-5 is normally open, and TB74-6 is normally closed. 1 Amp 24VAC is the maximum load.

Use Class 1 field supplied wiring.

8) Indoor unit interlock and SPD alarm terminals –

a. On any call for compressor operation, normally open contact is closed across terminals 70 and 71 for Circuit 1, and normally open contact is closed across terminals 70 and 230 for Circuit 2 from indoor room unit.

b. During SPD alarm, normally open contact is closed across terminals 12 & 13. SPD is an optional device.

9) CANbus shield terminal – Terminal for field shield connection of the CANbus field supplied cables. The shield of CANbus field supplied cables must not be connected to ground at the condenser.

10) Primary low voltage entrance – One 7/8” (22.2mm) diameter knockout that is free for customer low voltage wiring.

11) SPD entrance – One 7/8” (22.2mm) diameter knockout hole located at the bottom of the enclosure. High voltage surge protective device

(SPD) is optional.

NOTES:

1. Refer to specification sheet for unit voltage rating, full load amp, and wire size amp ratings.

2. The CANbus wiring is field supplied and must be:

- Braided shield or foil shield with drain wire

- Shield must be wired to ground at indoor unit

- 22-18AWG stranded tinned copper

- Twisted pair (minimum 4 twists per foot)

- Low Capacitance (15pF/FT or less)

- Must be rated to meet local codes and conditions

- EXAMPLES BELDEN 89207 (PLENUM RATED), OR ALPHA…

This is the start of the file's text. The full file is on GovTribe.