This is a Physical Plant Requirements attachment for a federal detention facility contract that specifies comprehensive infrastructure and office space requirements across multiple operational components.

The document outlines detailed facility requirements for Enforcement and Removal Operations (ERO), the Office of the Principal Legal Advisor (OPLA), and the Executive Office for Immigration Review (EOIR). ERO space must include a total of offices and workstations for leadership positions (Assistant Field Office Director, Officer in Charge, Intelligence Officer, Chief Immigration Enforcement Agent), supervisory and operational staff (Deportation Officers, Immigration Enforcement Agents, Detention & Removal Assistants), support personnel (Mission Support Specialists, Receptionists, Records Technicians, Mail/File Clerks), file rooms, conference rooms, break rooms, and specialized IT support rooms with climate control. OPLA space requires offices for the Deputy Chief Counsel and Assistant Chief Counsel, workstations for Legal Technicians and Mail/File Clerks, and support space. EOIR space must provide courtrooms capable of live and video teleconferencing, hard-walled offices, workstations, visitation space compliant with American Correctional Association standards, a separate secure entrance for judges with parking access and ADA compliance, and dedicated support space. The processing area must accommodate high-frequency alien processing at rates of up to 100 individuals at one time in compliance with ICE Hold Room Standards. All furniture and case goods shall be furnished by the service provider in accordance with ICE Design Standards. The service provider must supply complete IT and communications infrastructure, cabling, and equipment for ICE, OPLA, and IHSC operations as independent systems physically separate from the provider's own systems, with separate billing established for recurring service fees.

View the file

Other files

File Type Posted
Attachment 15 A0001 Turn-key pricing.xlsx XLSX spreadsheet
Attachment 10b A0001- Anticipated Transportation Routes Requirement B (Miami).xlsx XLSX spreadsheet
Attachment 04 A0001- Solicitation Question Template_Responses.xlsx XLSX spreadsheet
Attachment 01 A0001 - Turnkey Facility PWS (Non-IHSC)(Requirements A- Denver_ B -Miami and C- Philadelphia).pdf PDF
Attachment 01b A0001- Facility-Specific Requirements (Requirement B_ Miami).pdf PDF
70CDCR26R00000026 A0003.pdf PDF
Attachment 02 A0001 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle) (1).pdf PDF
Attachment 01a A0001- Facility-Specific Requirements (Requirement A_ Denver).pdf PDF
70CDCR26R00000026 A0002.pdf PDF
Attachment 15 Turn-key pricing.xlsx XLSX spreadsheet
70CDCR26R00000026 A0001.pdf PDF
Attachment 02 A0001 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle).pdf PDF
Attachment 01 A0001 - Turnkey Facility PWS (Non-IHSC) (Requirements A- Denver B -Miami and C- Philadelphia).pdf PDF
Attachment 14b DSCS Handbook 2025 (v. 4.2).pdf PDF
Attachment 10c - Anticipated Transportation Routes Estimate Requirement C (Philadelphia).pdf PDF
Attachment 14a DSCS __ 20JAN2026 (v. 4.2)_Example.xlsx XLSX spreadsheet
Attachment 10d - Anticipated Transportation Routes Requirement D (Seattle).pdf PDF
Attachment 01c - Facility-Specific Requirements (Requirement C Philadelphia).pdf PDF
Attachment 12 - Medical Services for Non-IHSC Facilities 2026_7.16.26.pdf PDF
Attachment 02a - Facility-Specific Requirements (Requirement D - Seattle).pdf PDF
Attachment 13 - Title 29 Labor Standards_2026AUG.pdf PDF
Attachment 06 - Detention-Transportation Template_2026AUG.xlsx XLSX spreadsheet
Attachment 14 DSCS __ 20JAN2026 (v. 4.2).xlsx XLSX spreadsheet
Attachment 10c1 - Enhanced Transport Requirements Requirement C (Philadelphia).pdf PDF
Attachment 01b - Facility-Specific Requirements (Requirement B Miami).pdf PDF
Attachment 01a - Facility-Specific Requirements (Requirement A Denver).pdf PDF
Attachment 02b - Stationary Guards (Requirement D- Seattle).pdf PDF
Attachment 03 - QASP_PRS_NDS 2026_2026AUG.pdf PDF
Attachment 10a - Anticipated Transportation Routes Requirement A (Denver).xlsx XLSX spreadsheet
Attachment 10b - Anticipated Transportation Routes Requirement B (Miami).xlsx XLSX spreadsheet
Attachment 04 - Solicitation Question Template.xlsx XLSX spreadsheet
Attachment 01 - Turnkey Facility PWS (Non-IHSC) (Requirements A- Denver B -Miami and C- Philadelphia).pdf PDF
Attachment 05 - PREA Regulations_2026AUG_.pdf PDF
Attachment 10 - Transportation Requirements_2026AUG.pdf PDF
Attachment 07 - Combating Trafficking in Persons_2026AUG.pdf PDF
70CDCR26R00000026.pdf PDF
Attachment 02 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle).pdf PDF
Attachment 08 - Privacy Rec Mgmt Safeguarding Info_2026AUG.pdf PDF
Attachment 03a - QASP_PRS_PBNDS_2026AUG.pdf PDF
Attachment 16 - Procedural Guidance for Complying with NEPA.pdf PDF
Attachment 03b - Contract Discrepancy Report Template_2026AUG.pdf PDF
Attachment 11 - Virtual Attorney Visitation_2026AUG.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 9 Physical Plant Requirements

(ERO WILL PROVIDE THIS DOCUMENT. TO ASSIST, PROVIDE THIS DOCUMENT TO THE COR TO GAUGE THEIR REQUIREMENT)

A. Enforcement and Removal Operations Office Space

The service provider shall refer to ICE Design Standards for specific office and workstation sizes and specific furnishing requirements for a bed facility. Please note, ICE Design Standards do not apply to existing buildings. The requirement include but are not limited to the following:

1. A total of offices and workstations as outlined below:

a. 1 Office - Assistant Field Office Director

b. 1 Office - Officer in Charge

c. 1 Office - Assistant Officer in Charge

d. 1 Office - Intelligence Officer

e. 1 Office - Chief Immigration Enforcement Agent

f. Offices - Supervisory Detention & Deportation Officers

g. Offices - Deportation Officers

h. Offices - Supervisory Immigration Enforcement Agents

i. Workstations - Immigration Enforcement Agents

j. Offices - Supervisory Deportation Assistant

k. Workstations - Detention & Removal Assistants

l. Office - Mission Support Specialist

m. Offices - Contracting Officer’s Representative

n. Office - Intelligence Research Specialist

o. Office - Training Officer

p. Workstations - Mission Support Assistant

q. Workstation – Receptionist

r. Workstation - OIC Secretary

s. Workstation - Records Tech

t. Workstation - Mail/File Clerk

u. File rooms (see Standards for size and quantity)

v. Conference rooms adjacent to or within ICE area (see Standards for size and quantity)

w. Employee break rooms (see Standards for size and quantity)

x. IT computer support rooms must be provided through out ICE space per the specifications. Including specialized requirements for climate control of IT equipment rooms for Public Health Service, Executive Office of Immigration Review, and ICE office area.

y. Actual location, layout, configuration, and size of rooms will be determined during the final design phase.

B. Office of the Principal Legal Advisor (OPLA) Space

The service provider shall refer to ICE Design Standards for specific office and workstation sizes and specific furnishing requirements for a bed facility. All furniture and case goods shall be furnished by the service provider in accordance with ICE Design Standards. The requirement include but are not limited to the following:

1. Office – Deputy Chief Counsel (see Standards for size)

2. Offices – Assistant Chief Counsel (see Standards for size)

3. Workstations - Legal Technicians (see Standards for size)

4. Workstation - Mail/File Clerk

5. Office support space must be provided per the ICE OPLA Design Standards.

C. Executive Office for Immigration Review (EOIR) Space

The service provider shall refer to ICE/EOIR Design Standards for specific office and workstation sizes and specific furnishing requirements for a bed facility. All furniture and case goods shall be furnished by the service provider in accordance with ICE Design Standards. The requirement include but are not limited to the following:

1. Courtrooms and accompanying office and support space as per the EOIR Design Standards for a bed facility. The office space is per the EOIR Design Standards. Each courtroom should have the capability to hold live court as well as hold video teleconferencing court. All furniture and case goods shall be furnished by the service provider in accordance with ICE Design Standards.

2. Hard walled offices (see Standards for size)

3. Workstations (see Standards for size)

4. Visitation space must be provided to meet the ACA and applicable standard.

5. Separate entrance for judges required with complete security system and access to parking lot. Must be ADA compliant.

6. EOIR Support Space must be provided per the EOIR Design Standards.

D. Health Services Space

Health Services Space: Health services will be provided by the service provider or if applicable, through its sub-service provider. Healthcare Services Design Standards shall be in accordance with applicable ICE requirements when provided by the service provider.

E. Processing Area

The processing area shall be designed to process aliens as required in high frequency rates and varying numbers i.e., a busload up to 100 aliens at one time. The processing area shall be in compliance with the ICE Hold Room Standard and the applicable standard to this agreement.

F. Furniture

All furniture and case goods shall be furnished by the service provider in accordance with ICE Design Guide and specifications, which include ICE support space and all operational components which include EOIR, OPLA and IHSC space as required in accordance with the ICE Design Standards.

G. ICE IT Equipment

ICE will provide and install IT equipment in office spaces for ICE personnel only, to include computer workstations and screens, printers and fax machines. All infrastructure, cabling, and interfacing equipment shall be provided by the service provider at time of construction.

NOTE: ICE IT system must be a complete, independent and physically separate system from the service provider’s IT system. The system shall serve all operational components: ICE, OPLA, and IHSC. EOIR shall have a separate system within EOIR IT space as per the EOIR Design Standards.

For further ICE and OPLA space requirements, please see Contract Detention Facility (CDF) Design Standards for Immigration and Customs Enforcement (ICE), May 14, 2007; addendums: ICE Cabling Standards; Phone Specifications.

H. Communication Equipment

1. The service provider shall purchase, install and maintain a complete and operating communication system, which includes but is not limited to: cabling, fiber optics, patch panels, landing blocks, circuits, PBX and voice mail, phone sets and other supporting infrastructure and supporting system in compliance with ICE specifications. Separate billing to ICE must be established on all reoccurring service fees for communications and IT. Systems shall be installed specifically for ICE use.

2. Service Provider to Insert specifications for communications system here.

NOTE: ICE communication system must be a complete, independent and physically separate system from the service provider communication system and billed separately. The system shall serve all operational components: ICE, OPLA, and IHSC. If applicable, EOIR shall have a separate system within EOIR IT space as per the EOIR Design.