Attachment 02a - Facility-Specific Requirements (Requirement D - Seattle).pdf

PDF 237 KB Posted

Attached to
Turn-key Detention Facilities
Solicitation number
70CDCR26R00000026
Issued by

About this file

This is an addendum to a federal contract solicitation that specifies facility-specific requirements for Requirement D within the Seattle Area of Responsibility (AOR).

Requirement D involves establishing an immigration detention facility located within 50 miles of the Seattle Field Office (12500 Tukwila International Blvd, Seattle, WA 98168), no more than 30 driving miles from a major hospital and emergency services, with access to public and commercial transportation and within 50 driving miles of Seattle-Tacoma International Airport. The facility must comply with National Detention Standards 2026 and accommodate approximately 1,400 male detainees, 200 female detainees, and 80 beds in a special management unit for administrative and disciplinary segregation, serving detainees at risk levels 1 through 3. The contractor must provide comprehensive administrative space for approximately 65 ICE/ERO staff (35 offices, 30 cubicles, 3 VTC rooms, 7 VAV rooms), plus additional support amenities including break rooms, gym, secure file rooms, and staff facilities. ICE/Processing/Holding Space requires secure holding capacity for at least 20 detainees (2 male, 1 female, 1 segregation) with processing stations, interview rooms, and vehicular sally port access. Health Services requires medical space for approximately 90 IHSC staff with administrative offices, intake screening rooms, ambulatory care units, dental offices, and an infirmary with 8 minimum beds for short-stay patients. Administrative support is required for approximately 25 OPLA staff and USCIS staff, along with EOIR courtroom space accommodating one judge per 60 detainees. The contractor must furnish all new furniture per ICE Design Standards, provide minimum electronic requirements including 175 phone lines, 10 fax lines, 5 VTC lines, and 10 copiers, secure on-site parking for 150 vehicles, and ground transportation services (historically 494,072 miles annually with 20,000 guard hours supporting 5,742 missions). Transportation routes span Washington and Oregon locations with guaranteed minimum mileage of 145,000 miles in Washington and 33,300 miles in Oregon. The staffing structure includes 135 total Case Processing Specialists distributed across multiple locations from Tacoma to Anchorage, Alaska.

View the file

Other files

File Type Posted
Attachment 02 A0001 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle) (1).pdf PDF
Attachment 01b A0001- Facility-Specific Requirements (Requirement B_ Miami).pdf PDF
70CDCR26R00000026 A0003.pdf PDF
Attachment 15 A0001 Turn-key pricing.xlsx XLSX spreadsheet
Attachment 10b A0001- Anticipated Transportation Routes Requirement B (Miami).xlsx XLSX spreadsheet
Attachment 04 A0001- Solicitation Question Template_Responses.xlsx XLSX spreadsheet
Attachment 01 A0001 - Turnkey Facility PWS (Non-IHSC)(Requirements A- Denver_ B -Miami and C- Philadelphia).pdf PDF
Attachment 01a A0001- Facility-Specific Requirements (Requirement A_ Denver).pdf PDF
70CDCR26R00000026 A0002.pdf PDF
Attachment 15 Turn-key pricing.xlsx XLSX spreadsheet
70CDCR26R00000026 A0001.pdf PDF
Attachment 02 A0001 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle).pdf PDF
Attachment 01 A0001 - Turnkey Facility PWS (Non-IHSC) (Requirements A- Denver B -Miami and C- Philadelphia).pdf PDF
Attachment 10a - Anticipated Transportation Routes Requirement A (Denver).xlsx XLSX spreadsheet
Attachment 10b - Anticipated Transportation Routes Requirement B (Miami).xlsx XLSX spreadsheet
Attachment 04 - Solicitation Question Template.xlsx XLSX spreadsheet
Attachment 01 - Turnkey Facility PWS (Non-IHSC) (Requirements A- Denver B -Miami and C- Philadelphia).pdf PDF
Attachment 05 - PREA Regulations_2026AUG_.pdf PDF
Attachment 10 - Transportation Requirements_2026AUG.pdf PDF
Attachment 07 - Combating Trafficking in Persons_2026AUG.pdf PDF
Attachment 06 - Detention-Transportation Template_2026AUG.xlsx XLSX spreadsheet
Attachment 14 DSCS __ 20JAN2026 (v. 4.2).xlsx XLSX spreadsheet
Attachment 10c1 - Enhanced Transport Requirements Requirement C (Philadelphia).pdf PDF
Attachment 09 - Physical Plant Requirements_2026AUG.docx DOCX document
Attachment 01b - Facility-Specific Requirements (Requirement B Miami).pdf PDF
Attachment 01a - Facility-Specific Requirements (Requirement A Denver).pdf PDF
Attachment 02b - Stationary Guards (Requirement D- Seattle).pdf PDF
Attachment 03 - QASP_PRS_NDS 2026_2026AUG.pdf PDF
Attachment 14b DSCS Handbook 2025 (v. 4.2).pdf PDF
Attachment 10c - Anticipated Transportation Routes Estimate Requirement C (Philadelphia).pdf PDF
Attachment 14a DSCS __ 20JAN2026 (v. 4.2)_Example.xlsx XLSX spreadsheet
Attachment 10d - Anticipated Transportation Routes Requirement D (Seattle).pdf PDF
Attachment 01c - Facility-Specific Requirements (Requirement C Philadelphia).pdf PDF
Attachment 12 - Medical Services for Non-IHSC Facilities 2026_7.16.26.pdf PDF
Attachment 13 - Title 29 Labor Standards_2026AUG.pdf PDF
70CDCR26R00000026.pdf PDF
Attachment 02 - Turnkey Facility PWS (IHSC) (Requirement D-Seattle).pdf PDF
Attachment 08 - Privacy Rec Mgmt Safeguarding Info_2026AUG.pdf PDF
Attachment 03a - QASP_PRS_PBNDS_2026AUG.pdf PDF
Attachment 16 - Procedural Guidance for Complying with NEPA.pdf PDF
Attachment 03b - Contract Discrepancy Report Template_2026AUG.pdf PDF
Attachment 11 - Virtual Attorney Visitation_2026AUG.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Addendum – Seattle AOR

Requirement D– Facility-Specific Requirements

Location Requirements Requirement D shall be located within 50 miles from the Seattle Field Office located at 12500 Tukwila International Blvd, Seattle, WA 98168, to maximize transportation and manpower efficiencies, and no more than 30 driving miles from a major hospital and emergency services. The facility shall have access to public and commercial transportation routes and services and must be located 50 driving miles or less from Seattle Tacoma International Airport SEA-TAC.

Applicable Detention Standard

National Detention Standards 2026

Estimated Population Size

Male Approximately 1,400

Female Approximately 200

Juvenile 0

Family 0

Special Management unit for administrative and discipline segregation

Yes, approximately 80 beds

Expected Risk Detainees

Level 1 (Low) Yes

Level 1.5 (Medium Low) Yes

Level 2 (Medium High) Yes

Level 3 (High) Yes

Facility, Detention and Administrative Space Approximate Requirements

ICE/ERO Administrative and support space for ICE staff of approximately 65 employees including:

35 Offices

30 Cubicles

3 VTC rooms

7 VAV rooms

Space requirements are in accordance with ICE CDF Design Standards.

Additional Administrative/Common Area Requirements

Break room with kitchenette/Conference Room

Gym

Secure File Room

Supply Room

2 Storage Rooms

3 Copier/Printer/Fax/Shredder Areas

Male Restroom

Female Restroom

ADMINISTRATIVE AND OFFICE SUPPORT SPACE FOR

ICE STAFF SERVICES (SUPPORT AREA FOR ALL ICE

EMPLOYEES):

Staff Break room

Vending area

Male Staff Lockers

Male Staff Toilet

Male Staff Showers

Male Staff Dressing Area

Female Staff Lockers

Female Staff Toilet

Female Staff Shower

Female Staff Dressing Area

Equipment Storage Room

Loading dock and staging

ICE COMMON SUPPORT SPACE

ICE Main Distribution Frame (MDF) Room

ICE Intermediate Distribution Frame (IDF) Room

ICE/Processing/Holding Space The Contractor shall provide a secure holding space with a capacity of at least 20 detainees, separate from the facility’s hold room area. This holding capacity must be broken down into, male (2), female (1) and segregation rooms (1).

The contractor will need to man and operate these hold rooms in accordance with the attached ICE policy 11087.2 Operations of ERO Holding Facilities.

Sufficient space to accommodate at least 3 processing stations

At least 3 interview rooms USCIS, ICE, OPR, JTTF, DOD, FBI, HSI, DPS, CBP

Security, control, and monitoring services for the holding cell.

Direct access to a vehicular sally port with search room.

Male/Female staff toilet

ICE/Health Services The Contractor shall provide medical space, as well as all furniture and case goods in accordance with IHSC Design Standards.

The Contractor shall provide administrative and support space for Health Services (IHSC) staff of approximately 90 employees.

ADMINISTRATION and COMMON SUPPORT UNIT

(Approximate Requirements):

Health Services Administrator (HSA) Office

Clinical Director (CD) Office

2 Assistant HSA Offices

Nurse Manager Office

Program Manager Office

Administrative Assistant Workstation

Work Area Multipurpose Room/Break Room/Conference Room

Training Room with 0 computer workstations

Equipment Storage for Training

HR Records Storage

14 x 16 Central Supply Room with mobile shelving / General Medical Storage for large boxes/shipping with receiving desk/workstation (shipping/receiving area)

COMMON SUPPORT SPACES (Approximate Requirements):

Medical Records Technician (MRT) Workstation

Medical Records Room (capacity of 3)

Records Retention Room / Storage

LAN Room

Pharmacy

Pharmacy Supply Room

Ambulatory Medical Supply Room

Medical Laboratory

Janitor Closet

1 Female Staff Toilet / Locker Room

1 Male Staff Toilet / Locker Room

Biohazard Waste / Storage Room

MEDICAL INTAKE and PROCESSING UNIT (Approximate Requirements):

4 Intake Screening Rooms with 4 workstations each

Tele-radiology Room (X-ray)

Eyewash / hand washing station

Unisex Staff Toilet

3 Medical workstations with desk area

Storage Room

AMBULATORY CARE UNIT (Approximate Requirements):

7 Exam Rooms

3 Detainee Holding Areas (Waiting - capacity of 5 each)

Medical lab

2 Dental Offices with 1 workstation(s) each

2 Dental Exam Room (Operatory)

Dental Lab

Dental Mechanical Room

Dental Supply Room

Nurse Coordinator Room

Urgent Care Room Treatment Room

1 Supply Room

1 Equipment Room

Telemedicine Machine Room

Guard Station

Staff Toilet

Detainee Toilet

Provider Office area with 7 workstations for documenting (charting, etc.)

SHORT STAY UNIT (Infirmary) – all rooms must comply with ADA (Approximate Requirements):

4 single Mental Health Rooms

Suicide Observation Room

1 Safety Cell

4 Respiratory Isolation Rooms w/ Vestibule

1 – Two-bed rooms for General Medical

Nurse Managers Office

Nurse Station w/ Security Officer

Detainee Shower

Medication Prep Room

Kitchenette

Infirmary Supply Room

Janitors Closet

Staff Toilet

1 Equipment Room(s)

1 Biohazard / Dirty Utility Room

1 Supply Room

Located in the designated medical housing unit, a minimum of 8 beds shall be provided for a short stay; this shall be separate from the total overall beds required for detainees.

ICE/ OPLA The Contractor shall provide administrative office/workstations space for approximately 25 employees including:

18 Attorneys Offices

5 Legal Assistants Workstations

1 Office Assistant Workstation

1 Mail Clerk Workstation

ADDITIONAL ADMINISTRATIVE AREAS FOR ICE

OPLA

STAFF (Approximate Requirements):

Break room with kitchenette

Secure File Room

Supply Room

Law Library/Conference Room

Classified File Room

Copier/Storage Room

Mail/File Clerk Office

Support workstation with scanner, printer, fax

U.S. Citizenship and Immigration Services (USCIS)

Approximately the following:

4 Offices

2 Cubicles

There shall be a separate USCIS holding room for detainees awaiting interview with an asylum officer. This holding area will accommodate a total of approximately 20 detainees at a time.

Each holding area (male and female) shall have its own restroom.

Executive Office for Immigration Review (EOIR) Space

The Contractor shall provide administrative and support space for EOIR to accommodate one judge per courtroom for each 60 detainees, for in person hearings, equipped with video/telephone conference capabilities. The Executive Office of Immigration Review (EOIR) requires space for employees as indicated using the June 2011 EOIR CDF Design guide, specifically the Space Requirements Summary chart within Section 4 Functional Requirements outlines the specific square footage required for each of the following:

PRIVATE OFFICES

Immigration Judges

Court Administrators

Law Clerks

Supervisors

OPEN SUPPORT SPACE / CUBES / LOW WALLS

Administrative staff

ADDITIONAL ADMINISTRATIVE AREAS FOR EOIR

STAFF:

Pro Bono Room

Copier/Mail Room

Secure File Room

Computer (ADP) Room

Female Staff toilet

Male Staff toilet

Janitor Closet

Printer Workstation

Supply Room

1 Visitation space (pro-bono room) must be provided to meet the ACA and detention standards.

EOIR space shall be contiguous.

A separate, Americans with Disabilities Act (ADA) compliant, entrance for judges and staff is required with complete security system and access to a parking lot.

The Contractor shall comply with the 2011 EOIR CDF Design Guide. The offices and support spaces shall be fully furnished with furniture (EOIR provides agency VOIP telephones), provide supplemental HVAC units in the Courtrooms and ADP rooms (typically 1 ½ tons each), Duress Alarms at the Reception window, Court Administrator office, conference room and mounted under the Judge’s benches in all Courtrooms.

Furniture Requirements All furniture and case goods shall be new and furnished by the Contractor in accordance with ICE Design Guide and specifications, which include all ICE Administrative office space and support space, EOIR, OPLA, and IHSC space as required in accordance with the ICE Design Standards.

Additional Electronic Requirements At a minimum:

175 phone numbers/lines/extensions

10 separate fax numbers/lines/extensions

5 VTC lines (PRI/T1) for 5 VTC systems

10 copiers (fax/scan capable) and supplies (such as paper and ink) – Contractor is responsible for maintenance and/or replacement of copiers in the event of failure.

Parking The Contractor shall provide secured and separate surface parking on-site for approximately 150 spaces at the facility exclusively for Government and ICE visitors use as follows:

Approximately 130 for employees

Approximately 20 for visitors

Transportation Requirements

In FY25, the vendor for this requirement drove approximately 494,072 miles and used 20,000 guard hours to support ground transportation activities. The vendor also provided 5,742 missions in FY25. This historical data does not constitute a guaranteed minimum number of miles and should be used only for planning purposes. The Offeror may be required to perform additional movements as directed by the

COR.

This “Transportation Requirements” information is provided only for reference for Offerors. This information shall not constitute a guaranteed minimum number of beds, detainees nor miles, nor shall it constitute a maximum number of miles required under any forthcoming contract.

Transportation Routes

To Spokane, WA/from Yakima, WA facility for Requirement A–

To Richland, WA/from Yakima, WA facility for Requirement A–

To Wenatchee, WA/from Yakima, WA facility for Requirement A-

To Yakima, WA/from NWIPC facility for Requirement A-

To Seattle, WA, Tukwila, WA, SeaTac Airport, anything approved by the COR/from NWIPC facility for Requirement A-

To Ferndale, WA/from NWIPC facility for Requirement A-

To Portland, OR/from NWIPC facility for Requirement A-

To Eugene, OR/from Portland, OR facility for Requirement A-

To Seattle, WA local runs*/from NWIPC facility for Requirements A- *medical appointments, jails, anywhere approved by the COR

To Portland, OR local runs/from Portland, OR facility for Requirement A-

To ICE Air location (Seattle, WA or Yakima, WA)/from NWIPC for Requirement A-

To Pendleton, OR (for Boise, ID)/from Yakima, WA facility for Requirement A-

Ad hoc runs as needed

Transportation Guaranteed Minimum mileage

Washington 145,000/Oregon 33,300

Guard Services

Minimum Hours None- NTE 6,000/mo.

Required postings/patrols Surveillance may be provided via a minimum of one (1) motorized security patrol for 24 hours.

Training

Required Training See PWS

Case Processing Specialists (CPSs)

135 total CPS positions across the Area of Responsibility:

CPS Breakdown

Location CPS Supervisor Manager

Tacoma, WA 98421 23 2 0

Tukwila, WA 98168 33 3 1

Ferndale, WA 98248 5 1 0

Yakima, WA 98902 10 1 0

Richland, WA 99352 5 1 0

Spokane, WA 99201 5 1 0

Wenatchee, WA 98801 5 1 0

Portland, OR 97239 20 2 1

Eugene, OR 97401 5 1 0

Medford, OR 97504 3 0 0

Anchorage, AK 99501 5 1 0

Totals 119 14 2

Historical Location

Northwest ICE Processing Center

1623 East J. St

Tacoma, WA 98421

File details come from the government source that posted it. Updated .