Attachment 01b - Facility-Specific Requirements (Requirement B Miami).pdf
PDF 182 KB Posted
- Attached to
- Turn-key Detention Facilities
- Solicitation number
- 70CDCR26R00000026
- Issued by
-
Immigration and Customs Enforcement
About this file
This is an addendum to a federal detention facility contract solicitation for the Miami Area of Responsibility (AOR), specifying facility-specific requirements for a DHS/ICE/ERO detention center.
Location and Basic Operations: The facility must be located within 50 driving miles of the DHS/ICE/ERO Miami Field Office at 865 SW 78th Avenue, Plantation, Florida, with appropriate proximity to emergency services and airport access. The facility will operate under National Detention Standards 2026 and accommodate approximately 600 male detainees, 100 female detainees, and zero juveniles and family units, with a special management unit for administrative and discipline segregation. Expected risk detainees include Level 1 (Low) and Level 1.5 (Medium Low) classifications only.
Administrative and Support Space Requirements: The contractor must provide ICE/ERO administrative space for approximately 80 employees, including 15 offices (100 sq ft each), 65 cubicles (8x8), video teleconferencing rooms, secure contact windows, breakroom with kitchenette, IT computer support rooms, conference rooms, secure file rooms, employee fitness center with showers and lockers, lactation room, and segregated male/female restrooms. Additional space includes staff training facilities, muster room (30-person capacity), weapon storage (80 gun lockers per NDS standards), mail room, supply rooms, storage rooms, and records retention room. ICE/Health Services requires medical space per IHSC Design Standards, including administration offices, medical intake and processing unit, ambulatory care unit with 3 exam rooms, pharmacy, laboratory, dental facilities, and tele-radiology (X-ray) capabilities. ICE/Processing/Holding Space must include secure holding for at least 50 detainees in large, small, male, female, and segregation configurations, with 5 processing stations, interview rooms, control room, 2 triage/exam rooms, and vehicular sally port with search room. ICE/OPLA requires 5 attorney offices, 5 legal assistant workstations, secure file room, law library/conference room, and classified file room. Executive Office for Immigration Review (EOIR) requires 2 courtrooms with video teleconferencing capability, 2 immigration judge offices (100 sq ft each), 2 court administrator offices, 6 workstations, and additional support spaces including pro bono room, computer (ADP) room, and separate ADA-compliant entrance with parking access. All furniture and case goods must be new and provided by the contractor per ICE Design Standards.
Operational Support Requirements: The contractor must provide secured surface parking for approximately 113 spaces (90 employee, 10 visitor, 13 bus spaces). Transportation services include approximately 83,333 miles and 20,000 guard hours annually (FY2025 historical data for planning purposes only, with no guaranteed minimum mileage). Security surveillance requires a minimum of two motorized security patrols for 24 hours. The facility requires 20 Case Processing Specialists (CPSs) on-site and 30 additional CPSs for the Miramar field office (Miramar, FL 33027). Electronic requirements include phone lines, fax numbers, VTC lines (PRI/T1), and copiers with maintenance responsibility assigned to the contractor.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Addendum – Miami AOR
Requirement B – Facility-Specific Requirements
Location Requirements The facility must be located within 50 driving miles from the DHS/ICE/ERO Miami Field Office, currently located at 865 SW 78th Avenue, Plantation, Florida. The facility shall be located within appropriate proximity and access to emergency services (medical, fire protection, law enforcement, etc.) and access to airport services for transportation requirements.
Detention Standards
National Detention Standards 2026
Estimated Population Size
Male Approximately 600
Female Approximately 100
Juvenile 0
Family 0
Special Management unit for administrative and discipline segregation
YES
Expected Risk Detainees
Level 1 (Low) Yes
Level 1.5 (Medium Low) Yes
Level 2 (Medium High) No
Level 3 (High) No
Facility, Detention and Administrative Space Approximate Requirements
ICE/ERO Administrative and support space for ICE staff of approximately 80 employees including:
15 Offices (100 sq ft)
65 Cubicles (8x8)
1 VTC rooms
1 Secure Contact Window for visitors
1 Waiting Room
Space requirements are in accordance with ICE CDF Design Standards.
Breakroom with kitchenette (i.e. small food storage/preparation area including a refrigerator, microwave and sink and garbage disposal at a minimum) - within the ERO area.
IT computer support rooms including specialized requirements for climate-controlled IT equipment
Conference room (with video teleconferencing (VTC) capability)
Secure file room – with safes
Male restroom with at least two stalls, two urinals, and lockers (not used/shared with aliens)
Female restroom with at least three stalls and lockers (not used/shared with aliens)
Training room – adjacent to or within ICE space
Employee fitness center/weight room that includes male/female showers and lockers in separate rooms – for ERO employees only
Employee firearms lockers that meet detention standards
Lactation room or pod with running water, refrigerator, and comfortable furniture that is washable. The Contractor is required to provide an ICE office and support space immediately adjacent to the detention federal facility.
Additional Administrative/Common Area Requirements
Conference Room (separate from the VTC rooms)
1 File Room with rolling file shelves
Mail Room
Supply Room
2 Storage Rooms
2 Open areas for Copier/fax/printer/shredder and tables for working with files
File Area
ADMINISTRATIVE AND OFFICE SUPPORT SPACE FOR ICE
STAFF SERVICES AND TRAINING (SUPPORT AREA FOR ALL
ICE EMPLOYEES):
Staff entrance vestibule Weapons drop area Training Office
Visiting Training Officer Office
Muster Room (capacity of 30 people)
Exercise Room
Physical Training Room Classroom/Computer Training Room
FATS Training Room
NDS approved weapon storage (80 gun lockers)
Vending area
Male Staff Lockers
Male Staff Toilet
Male Staff Showers
Male Staff Dressing Area
Female Staff Lockers
Female Staff Toilet
Female Staff Shower
Female Staff Dressing Area
Equipment Storage Room
Bulk Storage Room (Disposed Property)
Loading dock and staging
Records Retention Room
ICE COMMON SUPPORT SPACE
ICE common use mailroom
ICE Main Distribution Frame (MDF) Room
ICE Intermediate Distribution Frame (IDF) Room
ICE/Processing/Holding Space The Contractor shall provide a secure holding space with a capacity of at least 50 detainees, separate from the facility’s hold room area. This holding capacity must be broken down into large, small, male, female and segregation rooms.
The contractor will need to man and operate these hold rooms in accordance with the attached ICE policy 11087.2 Operations of ERO Holding Facilities.
Sufficient space to accommodate at least 5 processing stations
At least 1 interview rooms USCIS, ICE, OPR, JTTF, DOD, FBI, HSI, DPS, CBP
1 control room
2 triage/exam room
Security, control, and monitoring services for the holding cell and juvenile waiting areas.
Direct access to a vehicular sally port with search room.
Female staff toilet
Male staff toilet
ICE/Health Services The Contractor shall provide medical space, as well as all furniture and case goods in accordance with IHSC Design Standards.
ADMINISTRATION and COMMON SUPPORT UNIT
(Approximate Requirements):
Health Services Administrator (HSA) Office
Clinical Director (CD) Office
1 Assistant HSA Offices
Nurse Manager Office
Program Manager Office
Administrative Assistant Workstation
Work Area Multipurpose Room
Conference Room
Equipment Storage for Training
HR Records Storage
14 x 16 Central Supply Room with mobile shelving / General Medical Storage for large boxes/shipping with receiving desk/workstation (shipping/receiving area)
COMMON SUPPORT SPACES (Approximate Requirements):
Medical Records Technician (MRT) Workstation
Medical Records Room (capacity of 1)
Records Retention Room / Storage
LAN Room
Pharmacy
Pharmacy Supply Room
Ambulatory Medical Supply Room
Medical Laboratory
Janitor Closet
Biohazard Waste / Storage Room
MEDICAL INTAKE and PROCESSING UNIT (Approximate Requirements):
Tele-radiology Room (X-ray)
Eyewash / hand washing station
Unisex Staff Toilet
Storage Room
AMBULATORY CARE UNIT (Approximate Requirements):
3 Exam Rooms
1 clean utility room
1 dirty utility room
1 Detainee Holding Areas (Waiting - capacity of 28 each)
Medical lab
Dental Lab
Dental Mechanical Room
Dental Supply Room
Nurse Coordinator Room
Urgent Care Room Treatment Room
1 Supply Room
1 Equipment Room
Telemedicine Machine Room
Guard Station
Staff Toilet
Detainee Toilet
Provider Office area with 2 workstations for documenting (charting, etc.)
ICE/ OPLA The Contractor shall provide administrative office/workstations space according to the approximate requirements below:
5 Attorneys Offices (8x8)
5 Legal Assistants Workstations (8x8)
1 Office Assistant Workstation (8x8)
ADDITIONAL ADMINISTRATIVE AREAS FOR ICE OPLA
STAFF (Approximate Requirements):
Secure File Room
Law Library/Conference Room
Classified File Room
U.S. Citizenship and Immigration Services (USCIS)
No space required. Agency operates remotely.
Executive Office for Immigration Review (EOIR) Space
The Contractor shall provide administrative and support space for EOIR to accommodate one judge per courtroom for each 200 detainees, for in person hearings, equipped with video/telephone conference capabilities.
The Executive Office of Immigration Review (EOIR) requires space for employees as indicated using the June 2011 EOIR CDF Design guide, specifically the Space Requirements Summary chart within Section 4 Functional Requirements outlines the specific square footage required for each of the following:
COURT
2 courtrooms - Each courtroom will have the capability to hold live court as well as via video teleconferencing.
Secure Judge’s corridor
Public/detainee secure corridors
PRIVATE OFFICES
2 - Immigration Judges – Hard-walled office – 100 sq ft
2 - Court Administrators – (8x8)
6 workstations (8x8)
• Law Clerks
• Supervisors
OPEN SUPPORT SPACE / CUBES / LOW WALLS
Administrative staff
ADDITIONAL ADMINISTRATIVE AREAS FOR EOIR STAFF:
Conference Room
Pro Bono Room
Copier/Mail Room
Secure File Room
Computer (ADP) Room
Employee Break Room
Female Staff toilet
Male Staff toilet
Janitor Closet
Printer Workstation
Supply Room
1 Visitation space (pro-bono room) must be provided to meet the ACA and detention standards.
EOIR space shall be contiguous.
A separate, Americans with Disabilities Act (ADA) compliant, entrance for judges and staff is required with complete security system and access to a parking lot.
The offices and support spaces shall be fully furnished with furniture (EOIR provides agency VOIP telephones), provide supplemental HVAC units in the Courtrooms and ADP rooms (typically 1 ½ tons each), Duress Alarms at the Reception window, Court Administrator office, conference room and mounted under the Judge’s benches in all Courtrooms.
Furniture Requirements All furniture and case goods shall be new and furnished by the Contractor in accordance with ICE Design Guide and specifications, which include all ICE Administrative office space and support space, EOIR, OPLA, and IHSC space as required in accordance with the ICE Design Standards.
Additional Electronic Requirements
At a minimum:
As needed -- phone numbers/lines/extensions separate fax numbers/lines/extensions
VTC lines (PRI/T1) for VTC systems copiers (fax/scan capable) and supplies (such as paper and ink) – Contractor is responsible for maintenance and/or replacement of copiers in the event of failure.
Parking The Contractor shall provide secured and separate surface parking on-site for approximately 113 spaces (including bus parking) at the facility exclusively for Government and ICE visitors use as follows:
Approximately 90 for employees
Approximately 10 visitors
Approximately 13 buses
Transportation Requirements
In FY2025, the vendor for this requirement drove approximately 83,333 miles and used 20,000 guard hours to support ground transportation activities. The vendor also provided approximately 7,100 missions in FY2025. This historical data does not constitute a guaranteed minimum number of miles and should be used only for planning purposes. The Offeror may be required to perform additional movements as directed by the COR.
This “Transportation Requirements” information is provided only for reference for Offerors. This information shall not constitute a guaranteed minimum number of beds, detainees nor miles, nor shall it constitute a maximum number of miles required under any forthcoming contract.
See attachment “TRANSPORTATION”
Transportation Routes
See attachment “TRANSPORTATION”
Transportation Guaranteed Minimum mileage
None
Guard Services
Minimum Hours None
Required postings/patrols Surveillance may be provided via a minimum of two (2) motorized security patrols for 24 hours.
Training
Required Training See Performance Work Statement
Case Processing Specialists (CPSs)
For required facility: 20 CPS positions
For Miramar field office: 30 CPS positions
Location:
Miramar, FL 33027
Historical Location
BROWARD TRANSITIONAL CENTER
3900 NORTH POWERLINE ROAD
POMPANO BEACH, FL 33073
File details come from the government source that posted it. Updated .